Single Phase Sump, Effluent and Sewage - INSTRUCTION MANUAL - Xylem Applied ...

Page created by Mike Carr
 
CONTINUE READING
INSTRUCTION MANUAL
                                                              IM127R08

Single Phase Sump,
Effluent and Sewage
INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS
TABLE OF CONTENTS
SUBJECT                                                                                                                                                                             PAGE
Safety Instructions................................................................................................................................................................... 3
Pre-Installation Information and Checks.............................................................................................................................. 3
Lifting of Pump........................................................................................................................................................................ 4
Optional Guide Rail or Lift-Out System................................................................................................................................ 4
Piping....................................................................................................................................................................................... 4
Wiring and Grounding........................................................................................................................................................... 4
Selecting and Wiring Pump Control Panels and Switches..............................................................................................4-5
Installation in Sump without Slide Rails................................................................................................................................ 5
Installation................................................................................................................................................................................ 6
Operation................................................................................................................................................................................ 6
Float Switch and Panel Chart................................................................................................................................................. 7
Engineering Data.................................................................................................................................................................... 8
Insulation Resistance Readings............................................................................................................................................. 9
Typical Installations and Simplex Wiring Diagrams.......................................................................................................9-10
Trouble Shooting.................................................................................................................................................................. 11
Limited Warranty................................................................................................................................................................... 12

                         Owner’s Information
Pump Model Number:
Pump Serial Number:
Control Model Number:
Dealer:
Dealer Phone No.
Date of Purchase:                                       Installation:

Current Readings at Startup:
                                           1Ø
                           Amps:
                           Volts:

2
SAFETY INSTRUCTIONS                                                  WARNING      Risk of electric shock – this pump is
                                                                                  supplied with a grounding conductor
 TO AVOID SERIOUS OR FATAL PERSONAL INJURY                        and grounding-type attachment plug. To reduce the risk
 OR MAJOR PROPERTY DAMAGE, READ AND                               of electric shock, install only on a circuit protected by a
 FOLLOW ALL SAFETY INSTRUCTIONS IN MANUAL                         ground fault circuit interrupter (GFCI) with a rated trip
 AND ON PUMP.                                                     current of not more than 30 mA.
 THIS MANUAL IS INTENDED TO ASSIST IN THE                             WARNING This unit contains lubricant oil: always put
 INSTALLATION AND OPERATION OF THIS UNIT                                          in place the necessary measures to ensure
 AND MUST BE KEPT WITH THE PUMP.                                  that any spilled lubricant does not disperse in the
                                                                  environment. It is prohibited to dispose of lubricating
                This is a SAFETY ALERT SYMBOL.                    fluids in the environment.
                When you see this symbol on the pump
                or in the manual, look for one of the fol-            WARNING If the supply cord is damaged, it may
                lowing signal words and be alert to the                           only be replaced by expert and qualified
                potential for personal injury or property         people in order to avoid a hazard. Only use original spare
                damage.                                           parts to replace faulty components. Unsuitable spare
                                                                  parts may cause the product to work incorrectly and
     DANGER Warns of hazards that WILL cause                      cause hazards for people and property.
            serious personal injury, death or major
            property damage.                                      IMPORTANT PRE-INSTALLATION
                Warns of hazards that CAN cause                   INFORMATION
    WARNING
                serious personal injury, death or major                  The pump must be connected to a dedicated
                property damage.                                         electrical circuit protected by a properly sized circuit
           Warns of hazards that CAN cause per-                   breaker or fuses. Install a disconnect where required by
   CAUTION sonal injury or property damage.                       code. Code questions should be directed to your
                                                                  electrical inspector.
 NOTICE: INDICATES SPECIAL INSTRUCTIONS
                                                                         Pumps and floats equipped with a 3-prong ground-
          WHICH ARE VERY IMPORTANT AND
                                                                         ed plug must be connected to a 3-wire receptacle.
          MUST BE FOLLOWED.
                                                                  Do not attach to extensions or connectors without a
 THOROUGHLY REVIEW ALL INSTRUCTIONS AND                           3-prong grounded plug. NOTE: Removing the plug from
 WARNINGS PRIOR TO PERFORMING ANY WORK                            the power cord is not allowable per NEC code. Removing
 ON THIS PUMP.                                                    the plug will void the agency listing.
 MAINTAIN ALL SAFETY DECALS.                                           CAUTION This pump has been evaluated for use
                                                                                     with water only.
   WARNING        All electrical work must be performed by a      Risk of electric shock – this pump is supplied with a
                  qualified technician. Always follow the         grounding conductor and grounding-type attachment
National Electrical Code (NEC), or the Canadian Electrical        plug. To reduce the risk of electric shock, be certain that
Code, as well as all local, state and provincial codes. Code      it is connected only to a properly grounded, grounding-
questions should be directed to your local electrical 		          type receptacle.
inspector. Failure to follow electrical codes and OSHA safety
standards may result in personal injury or equipment dam-              WARNING This product can expose you to
                                                                                      chemicals including Lead and
age. Failure to follow manufacturer’s installation instructions   Phthalate (DINP), which are known to the State of
may result in electrical shock, fire hazard, personal injury      California to cause cancer and birth defects or other
or death, damaged equipment, provide unsatisfactory               reproductive harm. For more information go to:
performance, and may void manufacturer’s warranty.                www.P65Warnings.ca.gov.
    WARNING Pumps are not designed for use in swim-
                  ming pools, open bodies of water, hazard-       GENERAL INFORMATION
ous liquids, or where flammable gases exist. These fluids         Sump pumps are designed to operate intermittently and
and gases may be present in containment areas. Tank or            usually seasonally. It is recommended that you test the
wetwell must be vented per local codes.                           pump before your rainy season begins to insure that the
Only pumps specifically Listed for Class 1, Division 1 are        pump and switch are operating properly.
allowable in hazardous liquids and where flammable
gases may exist. See specific pump catalog bulletins or           We suggest installing a high water alarm system and a
pump nameplate for all agency Listings.                           battery back-up pump system for finished basements
                                                                  or areas where flooding will cause property damage. A
    WARNING Disconnect and lockout electrical power               back-up generator is another option you can discuss with
                  before installing or servicing any electrical   your pump installer. Most power outages occur during
equipment. Many pumps are equipped with automatic                 rain storms, just when you need your sump pump the
thermal overload protection which may allow an over-              most! Pump manufacturer’s warranties cover only the
heated pump to restart unexpectedly.                              pump. Labor and incidental damage such as flooding is
    WARNING This pump is not to be used by persons                not covered.
                  (including children) with reduced physi-
cal, sensory or mental capabilities, or lack of experience        PRE-INSTALLATION CHECKS
and knowledge, unless they have been given supervision            Open all cartons and inspect for shipping damage.
or instruction concerning use of the pump by a person             Report any damage to your supplier or shipping carrier
responsible for their safety.                                     immediately.
Children should be supervised to ensure that they do not
play with the pump                                                                                                             3
Important: Always verify that the pump nameplate                 backwards and may cause premature seal and/or bear-
Amps, Voltage, Phase, and HP ratings match your control          ing wear. If the pump is turning backwards when it is
panel and power supply.                                          called on to start the increased torque may cause dam-
Many of our sewage pumps are oil-filled. If there are any        age to the pump motor and/or motor shaft and some
signs of oil leakage or if the unit has been stored for an       single-phase pumps may actually run backwards.
extended period check the oil level in the motor dome            Install an adequately sized gate valve AFTER the check
and the seal housing, if so equipped.                            valve for pump, plumbing and check valve maintenance.
Check the motor cover oil level through the pipe plug on         Important – Before pump installation. If pumping
top of the unit. The motor chamber oil should just cover         water, drill a 1⁄8” (3.2mm) relief hole. If pumping waste wa-
the motor. Do not overfill, leave room for expansion!            ter containing solids, drill a 3⁄16” (4.8mm) relief hole in the
If low, refill with an ASTM 150 turbine oil. Replace the plug.   discharge pipe. It should be located within the wetwell,
                                                                 2” (51mm) above the pump discharge but below the
Oil is available in 5 gallon cans through our distributors.      check valve. The relief hole allows any air to escape from
You can also source oil locally at motor repair shops. Typical   the casing. Allowing liquid into the casing will insure that
oil brands are: Shell Turbo 32, Sunoco Sunvis 932, Texaco        the pump can start when the liquid level rises. Unless a re-
Regal R&O 32, Exxon Nuto 32 and Mobil DTE Light.                 lief hole is provided, a bottom intake pump could “air lock”
Check the strain relief nut on power cable strain assem-         and will not pump water even though the impeller turns.
blies. Power cables should be torqued to 75 in. lbs. for         All piping must be adequately supported, so as not to
#16 cables and 80 in. lbs. for all other cable assemblies.       impart any piping strain or loads on the pump.
Warranty does not cover damage caused by connecting              The pit access cover must be of sufficient size to allow for
pumps and controls to an incorrect power source (volt-           inspection, maintenance and crane or hoist service.
age/phase supply).
Record the model numbers and serial numbers from the             WIRING AND GROUNDING
pumps and control panel on the front of this instruction         Important notice: Read Safety Instructions before
manual for future reference. Give it to the owner or affix it    proceeding with any wiring.
to the control panel when finished with the installation.
                                                                      Use only stranded copper wire to pump/motor and
LIFTING OF PUMP                                                       ground. The ground wire must be at least as large as
                                                                      the power supply wires. Wires should be color coded
  WARNING DO NOT LIFT, CARRY OR HANG                                  for ease of maintenance and troubleshooting.
          PUMP BY THE ELECTRICAL
          CABLES. DAMAGE TO THE                                       Install wire and ground according to the National
          ELECTRICAL CABLES CAN CAUSE                                 Electrical Code (NEC), or the Canadian Electrical
          SHOCK, BURNS OR DEATH.                                      Code, as well as all local, state and provincial codes.
                                                                      Install an all leg disconnect switch where required by
                                                                      code.
Hazardous voltage
can shock, burn or                                                    Disconnect and lockout electrical power before
cause death.
                                                                      performing any service or installation.
Lift the pump with an adequately sized chain or cable at-             The electrical supply voltage and phase must match
tached to the lifting eye bolt. DO NOT damage electrical              all equipment requirements. Incorrect voltage or
and sensor cables while raising and lowering unit.                    phase can cause fire, motor and control damage, and
                                                                      voids the warranty.
OPTIONAL GUIDE RAIL
OR LIFT-OUT SYSTEM                                                    All splices must be waterproof. If using splice kits
                                                                      follow manufacturer’s instructions.
In many effluent and sewage basins or lift stations it is
advisable to install the pump on a guide rail system or             WARNINGSelect the correct type and NEMA grade
on a lift-out adapter to facilitate installation and removal               junction box for the application and
for inspection and/or service. Most codes do not allow                     location. The junction box must insure dry,
personnel to enter a wetwell without the correct protective                safe wiring connections.
equipment and training. Guide rails are designed to allow          WARNING Seal all controls from gases present which
easy removal of the pump without the need for entry into                   may damage electrical components.
the wetwell or need to disturb piping. The guide rail or lift-
out adapter should locate the pump opposite the influent          WARNING FAILURE TO PERMANENTLY GROUND
                                                                           THE PUMP, MOTOR AND CONTROLS
opening preventing stagnate areas where solids can settle.       Hazardous
                                                                           BEFORE CONNECTING TO POWER CAN
The basin or pit must be capable of supporting the weight        voltage
                                                                           CAUSE SHOCK, BURNS OR DEATH.
of the pump and guide rail. The pit floor must be flat.
NOTICE: FOLLOW THE INSTRUCTIONS THAT ARE                         SELECTING AND WIRING
            PROVIDED WITH THE GUIDE RAIL ASSEMBLY.               PUMP CONTROL PANELS AND SWITCHES
PIPING                                                           FLOAT SWITCH TYPES
                                                                 There are three types of float switches typically used on
Discharge piping should be no smaller than the pump              single phase pumps; single action, vertical and wide
discharge diameter and kept as short as possible, avoid-         angle.
ing unnecessary fittings to minimize friction losses.
                                                                 Single action control switches can only be connected
Install an adequately sized check valve matched to the           through a control panel. Connecting them directly to a
solids handling capability of the pump to prevent fluid          pump will cause rapid cycling and may burn up the motor,
backflow. Backflow can allow the pump to “turbine”
4
and/or the motor start switch and/or the float switch. If        WARNING PLUG-CONNECTED UNITS MUST
using single action switches with a control panel please                 BE CONNECTED TO A PROPERLY
see the Float Switch and Panel Section.                                  GROUNDED, GROUNDING TYPE RE-
Vertical mechanical float switches with piggyback plugs                  CEPTACLE.
are available for single phase pumps. They are an ideal                             ON NON-PLUG UNITS, DO NOT RE-
choice where there is limited space for a switch. They                              MOVE CORD AND STRAIN RELIEF. DO
require less room than a wide angle switch because they        Hazardous voltage    NOT CONNECT CONDUIT TO PUMP.
travel in a vertical direction. Typical model numbers start    can shock, burn or
                                                               cause death.
with A2H…
                                                              Pumps with bare lead power cords can be hard-wired to
Wide angle float switches are the most popular type.
                                                              a float switch, wired to a 1Ø contactor, a Simplex con-
They can be directly connected to a pump or to a control
                                                              troller or a Duplex controller. Always verify that the float
panel. The “tether length” or the distance from the switch
                                                              switch is rated for the maximum run amperage, maxi-
body to the pivot point controls the On and Off points
                                                              mum starting amperage, and the HP rating on the pump.
and the amount pumped in one cycle. The pivot point
                                                              Single-phase waste water pumps contain on-winding
is where the float is attached either to the pump or the
                                                              overloads, unless noted on the pump nameplate. See
discharge pipe. See Figures 1 - 5.
                                                              Figures 1 and 2.
SETTING THE FLOAT SWITCHES
There are no absolute rules for where to set the float        SINGLE PHASE CONTROL PANELS:
switches, it varies from job to job.                          Control panels are available as Simplex (controls 1 pump)
                                                              or Duplex (controls 2 pumps). Our standard control
Suggested Rules to Follow:
                                                              panels are available with many standard features and can
All floats should be set below the Inlet pipe!                be built with our most popular options. We also custom
Off Float: Best: set so the water level is always above the   build panels which offer many more design options than
top of the pump (motor dome). Next Best: set so the wa-       the standard panels. Custom control panels are available
ter level is not more than 6” below the top of the pump.      in many different configurations. Custom panel quote
On Float: set so the volume of water between the On           requests may be forwarded to Customer Service through
and Off floats allows pumps of 1½ HP and under to oper-       any authorized distributor.
ate for 1 minute minimum. Two (2) HP and larger pumps         Our standard duplex panels feature a solid-state printed
should run a minimum of 2 minutes. Basin literature           circuit board design with standard high level alarm cir-
states the gallons of storage per inch of basin height.       cuits. Other standard features are: an auxiliary dry alarm
Lag/Alarm Float(s): should be staggered above the             contact for signaling a remote alarm and float switch po-
Off and On floats. Try to use most of the available stor-     sition indicator lights. Most standard panels are in stock
age provided by the basin, save some space for reserve        for immediate delivery.
storage capacity. See Diagrams and Charts in Float Switch
Chart Section.
                                                              INSTALLATION IN SUMP WITHOUT
PANEL WIRING DIAGRAMS                                         SLIDE RAILS
Our control panels are shipped with instructions and
wiring diagrams. Use those instructions in conjunction        Is your basin sized correctly and the proper type for the
with this IOM. Electrical installation should be performed    location?
only by qualified technicians. Any problem or questions           Diameter - It must be wide enough to allow the pump
pertaining to another brand control must be referred              and switch to physically fit and provide room for the
to that control supplier or manufacturer. Our technical           switch to operate freely. The vertical switch models
people have no technical schematics or trouble shooting           typically require less diameter than the wide-angle
information for other companies’ controls.                        float models. See “min. basin diameter” in Chart 1.
ALARMS
We recommend the installation of an alarm on all Waste-
                                                                     CAUTION Depth - It must be deeper than the
                                                                                     minimum depth at which the switch
water pump installations. Many standard control panels            turns the pump On. As an example, if the pump turns
come equipped with alarm circuits. If a control panel is          on at 15” you want to use a basin deeper than 15”.
not used, a stand alone high liquid level alarm is avail-         See “On level” in Chart 1.
able. The alarm alerts the owner of a high liquid level in                           Style - There are several sump basin
the system so they can contact the appropriate service               WARNING
                                                                                     styles available. The location of the
personnel to investigate the situation.                           sump determines if you require a cover and what type
SINGLE PHASE PUMPS                                                you require. It is important to keep debris from enter-
Single phase (1Ø) pumps may be operated using a                   ing the sump and clogging the pump. An open sump
piggyback or hard wired float switch, a contactor, or a           in a traffic area such as a basement is dangerous. If
Simplex or Duplex control panel. See Figures 1, 2 and 5.          children or pets will be playing in the area a bolt-on or
All 1/3 and ½ HP, 115 or 230 volt pumps, and some ¾ and           child-proof cover is recommended.
1 HP pumps, are supplied with plug style power cords.         The pump can be placed directly on the bottom of a poly
They may be plugged into piggyback float switches for         or fiberglass sump basin or a concrete sump bottom. If
simple installations. It is allowable to remove the plugs     the bottom is packed gravel the stones must be larger
in order to hardwire or connect to a Simplex or Duplex        than ½” (13mm) in diameter and the pump should be
controller. Removing the plug neither voids the warranty      placed on bricks for support.
nor violates the agency Listings. See Figure 5.
                                                              After connecting the discharge pipe to the pump it can
                                                              be lowered into the sump (basin). Always lower the
                                                                                                                           5
pump by the handle and the pipe, never by the power             Packaged Sewage Systems – Inspect unit for damage.
cord. Place the pump against the basin wall so the switch       Return damaged units to the distributor. Install on solid,
is to the center. See “Installation Data”.                      level ground. Remove all tape from discharge pipe, vent
                                                                hole, float switch and inlet. Check to insure that the float
Check to insure all piping connections are tight. The           swings freely and is attached to the pump. Install the
pipes should be supported by fastening to floor joists          grommet in the inlet hole and lubricate it before install-
or wall. This will prevent the pump from moving in the          ing the inlet pipe. Connect the vent per code. If installing
sump. If it moves the switch could get stuck and either         outdoors protect the unit from freezing. Install a union
keep the pump running or not let it turn on.                    and check valve per valve manufacturer’s instructions.
The power to the outlet should be Off at this point. The        Install a gate valve on the discharge side of the check
dedicated outlet should supply power only to the pump.          valve for plumbing maintenance. See Typical Installation
                                                                Drawing 1.
Our sump pumps have either a single power cord for
pumps with built-in switches or two power cords for
pumps with piggyback switches:                                  OPERATION
  Built-In/Single Cord - plug the single power cord into a      Once the piping connections are made and checked you
  dedicated power outlet.                                       can run the pumps.
  Piggyback/Two Power Cords - insert the piggyback              Piggyback Switch Operation – Plug the piggyback
  switch male plug into a dedicated power outlet. You           switch into a dedicated grounded outlet and then plug
  then plug the standard male pump plug into the back,          the pump into the switch. Test the pump by filling the
  female side, of the piggyback switch plug.                    wetwell until the pump goes On. If the pumps run but
                                                                fail to pump, they are probably air locked, drill the relief
Fasten the power cords to the discharge pipes using tie         holes per the instructions in the Piping Section.
wraps or electrical tape. Coil and store any excess power
cord outside the sump.                                          Check the operating range to insure a minimum one min-
                                                                ute run time and that the pump goes Off in the correct
INSTALLATION                                                    position. Note: Small package systems will normally have
                                                                a fast ON-OFF cycle.
STANDARD PUMP INSTALLATION
Connect the pump(s) to the guide rail pump adapters             Control Panel Operation – Fill the wetwell with clear
or to the discharge piping. Guide rail bases should be          water.
anchored to the wetwell floor.                                  Use the pump H-O-A (Hand-Off-Automatic) switches in
Complete all wiring per the control panel wiring dia-           Hand to test the pumps. If they operate well in Hand pro-
grams and NEC, Canadian, state, provincial and/or local         ceed to test Automatic operation. If the pumps run but
codes.                                                          fail to pump, they are probably air locked, drill the relief
                                                                holes per the instructions in the Piping Section.
    !   DANGER        DO NOT PLACE HANDS IN PUMP
                      SUCTION WHILE CHECKING                    Place Control Panel switch(es) in Automatic position and
                      MOTOR ROTATION. TO DO SO WILL             thoroughly test the operation of the ON, OFF, and Alarm
                      CAUSE SEVERE PERSONAL INJURY.             floats by filling the wetwell with clear water. Important:
                                                                Failure to provide a Neutral from the power supply to a
                      Lower the pump(s) into the wetwell.       1Ø, 230 volt Control Panel will not allow the panel control
                      Check to insure that the floats will      circuit to operate. The Neutral is necessary to complete
                      operate freely and will not contact the   the 115 volt control circuit.
Hazardous Machinery
                      piping.                                   Check voltage and amperage and record the data on the
PRE-PACKAGED SYSTEM INSTALLATION                                front of this manual for future reference. Compare the
Connect the piping per local codes and the drawings in          amperage readings to the pump nameplate maximum
Typical Drawings Section.                                       amperage. If higher than nameplate amperage investi-
                                                                gate cause. Operating the pump off the curve, i.e. with
Sink Drain Systems – Inspect unit for damage. Return            too little head or with high or low voltage will increase
damaged units to the distributor. Install on solid, level       amperage. The motor will operate properly with voltage
ground. Hand tighten the piping into the Inlet. Con-            not more than 10% above or below pump nameplate
nect the Discharge to the main drain line. The discharge        ratings. Performance within this range will not necessarily
should contain a union and a check valve. See Typical           be the same as the published performance at the exact
Installation Drawing 2.                                         rated nameplate frequency and voltage. Correct the
                                                                problem before proceeding.
                                                                Reset the Alarm circuit, place pump switch(es) in the Au-
                                                                tomatic position and Control Switch in ON position. The
                                                                system is now ready for automatic operation.
                                                                Explain the operation of the pumps, controls and alarms
                                                                to the end user. Leave the paperwork with the owner or
                                                                at the control panel if in a dry, secure location.

6
FLOAT SWITCH AND PANEL CHART
The purpose of this chart is to show the required switch
quantities and the function of each switch in a typical                                Discharge
wastewater system. The quantities required vary de-
pending on the switch type, single-action or wide-angle.
Switch quantities also vary by panel type: simplex with
and without alarms, and duplex with alarms.
Duplex Panels using single-action switches:
Three Float Panel Wiring				                                      Inlet

SW1       Bottom         Pumps Off
SW2       Middle         1st Pump On                           Alarm SW3
SW3       Top            2nd Pump & Alarm On
                                                           Pump On SW2
Four Float Panel Wiring ➁
SW1        Bottom           Pumps Off
SW2        2nd              1st Pump On                     Pump Off SW1
SW3        3rd              2nd Pump On
SW4        Top              Alarm On

Duplex Panels using wide-angle switches:
Three Float Panel Wiring
SW1       Bottom            1st Pump On/Both Off
SW2       Top               2nd Pump & Alarm On                            Simplex ➀
Four Float Panel Wiring
SW1        Bottom           1st Pump On/Both Off
SW2        Middle           2nd Pump On
SW3        Top              Alarm On

                                                                                       Discharge
Simplex Panel using single-action switches:
Simplex Panel with Alarm ①
SW1       Bottom          Pump Off
SW2       Middle          Pump On
SW3       Top             Alarm On/Off

Simplex Panel with No Alarm                                      Inlet
SW1       Bottom          Pump Off
SW2       Top             Pump On
                                                               Alarm SW4

Simplex Panel using wide-angle switches:                    Lag Pump On
                                                                SW3
Simplex Panel with Alarm                                   Lead Pump On
                                                               SW2
SW1       Bottom         Pump On/Off
SW2       Top            Alarm On/Off
                                                                Pump Off
                                                                  SW1
Simplex Panel with No Alarm
SW1		                     Pump On/Off

                                                                           Duplex ➁

                                                                                              7
ENGINEERING DATA

Engineering data for specific models may be found in your catalog and on our website (address is on the cover).
Control panel wiring diagrams are shipped with the control panels. Please use the control panel drawings in conjunction with this instruction
manual to complete the wiring.

                                                          PUMP OPERATION
                     Minimum Submergence                                                         Maximum Fluid Temperature
      Continuous                                                                   Continuous
                                      Fully Submerged                                                                       104º F 40º C
         Duty                                                                       Operation
      Intermittent                                                                 Intermittent
                                    6” Below Top of Motor                                                                   140º F 60º C
          Duty                                                                      Operation

           Pumpmaster and Pumpmaster Plus -
                     Hard Wired

                                                                                     Single-Action Float Switch
                                                                                        “Typical” Installation
                                                                                                                                      WEIGHT

                                                                                                                                           6" (15.3 cm)

                             Figure 1

                                                                                  8" (20.3 cm) TURN ON LEVEL
                                                                                                                                           6" (15.3 cm)

                 Double Float - Hard Wired
                                                                                                                 Figure 4

                                                                                                    Wide-Angle Float Switch
                                                                                                                             Piggyback
                                                                                                               Pump plug     switch plug
                             Figure 2

                                                                                                                    Pumping
                Determining Pumping Range                                                                            range

                                                                                                                  Figure 5

                             Figure 3
8
INSULATION RESISTANCE READINGS

Normal Ohm and Megohm Values between all leads and ground

         Condition of Motor and Leads                              Ohm Value                   Megohm Value
 A new motor (without drop cable).                             20,000,000 (or more)               20 (or more)
 A used motor which can be reinstalled in well.                10,000,000 (or more)               10 (or more)
 Motor in well. Readings are for drop cable plus motor.
 New motor.                                                    2,000,000 (or more)                2 (or more)
 Motor in good condition.                                      500,000 - 2,000,000                   .5 - 2
 Insulation damage, locate and repair.                           Less than 500,000                Less than .5

Insulation resistance varies very little with rating. Motors of all HP, voltage and phase ratings have similar values
of insulation resistance.
Insulation resistance values above are based on readings taken with a megohmmeter with a 500V DC output.
Readings may vary using a lower voltage ohmmeter, consult factory if readings are in question.

TYPICAL INSTALLATIONS

                                                                                       DISCHARGE
                                                                                       PIPING WITH
                                                                                       UNION AND
                                                                                       CHECK VALVE
TETHER
LENGTH

                                                          VENT

                                   GATE VALVE

                         CHECK VALVE

      VENT

                                                                                                    INLET PIPING
                                                                                                    WITH UNION
                                                                                                    AND TRAP

                                                                                      Drawing 2
                                                    INFLUENT
             ON

                                             BASIN

             OFF

                       Drawing 1
                                                                                                                        9
NOTE: WHEN USING SEPARATE 115 VAC CONTROL POWER SUPPLY, REMOVE
                                    GND              J1         JUMPER (J1) FROM TERMINALS (L1) AND LL1). CONNECT 15 AMP MAX.
                                                                PROTECTED 115 VAC SUPPLY TO TERMINALS (LL1) AND (N) WITH
                                          LL1
                                                                THE NEUTRAL OF THE SUPPLY TO (N).

TYPICAL INSTALLATIONS (continued)
                  A 230 VOLT SYSTEM           CONTROL
                  REQUIRES A 4 WIRE           ON-OFF

Simplex Single Phase Wiring Diagram S10020
                  POWER SUPPLY LINE
                  L1, L2, N AND GND.
                  WITHOUT    A NEUTRAL
                          115/230 VAC (FOR 115 VAC, USE TERMINALS L1 AND N, JUMP L2 AND N).
                  THE CONTROL     CIRCUIT
                          SINGLE PHASE, 60 Hz
                  WILL NOT WORK.                                          S1                                                                                                             RUN
                                              L1                                                                                                 T1
                                                                                                                                                       HAND
                                                                                                                                                                 PUMP
                                                                                              S1-AUX
                                              L2                                                                                                 T2    OFF
                                                                                                                                                                                             S1

                                               N
                                                            1                        2                          3                                      AUTO
                                                                NOTE: WHEN USING SEPARATE 115 VAC CONTROL POWER SUPPLY, REMOVE
                                              GND          J1         JUMPER (J1) FROM TERMINALS (L1) AND LL1). CONNECT 15 AMP MAX.
                                                                  OFFPROTECTED
                                                                       FLOAT      115 VAC SUPPLY TO TERMINALS (LL1) AND (N) WITH
                                                                                  ON FLOAT
                                                    LL1
                                                                      THE NEUTRAL OF THE SUPPLY TO (N).
                                                                                                                                                                                  FLASH HIGH
                                                                                                                                                                 FLASHER
                          A 230 VOLT SYSTEM               CONTROL
                          REQUIRES A 4 WIRE               ON-OFF
                                                                                     4                                                                                                       R1
                          POWER SUPPLY LINE
                          L1, L2, N AND GND.
                          WITHOUT A NEUTRAL                                                                                                                     R2
                                                                 ALARM FLOAT
                          THE CONTROL CIRCUIT                                                                                                                                         HORN
                          WILL NOT WORK.                                                                                                                                    RUN
                                                          TEST                                                                                                 SILENCE
                                                                                                                                                HAND
                                                                                              S1-AUX                                                                                         R2
                                                                                                                                                OFF
                                                                                                                                                                             S1
                                                                                                                                                                R2
                                                                  1                      2                  3                                   AUTO

                                                                         OFF FLOAT           ON FLOAT

                                                                                                                                                                         FLASH HIGH
                                                                                                                                                       FLASHER

                                                                                         4                                                                                   R1

                                                                                                                        R1                            R2
                                                                       ALARM FLOAT
                                                                                                                                                                           HORN

                                                                TEST                                                                                 SILENCE
                                                                                                           5                         6                                       R2
                                                                                                        HIGH LEVEL ALARM                              R2
                                                                                                        DRY CONTACTS
                                                                          J1

                                                                               L1    L2       LL1      N            1        2           3      4          5         6      T1          T2

                                          2 FOR 115 VAC OPERTION,
                                          USE TERMINALS L1 AND N,
                                                                                                                    R1
                                          JUMP TERMINALS L2 AND N.

                                                                                                                                                                R1

                                                                                                        5                        6
                                                                                                                                                      DRY CONTACTS
                                                                                                        HIGH LEVEL ALARM
                                                      115/230 VAC 2                                     DRY CONTACTS
                                                                                                                                             ALARM
                                                      SINGLE PHASE
                                                                                                                                             FLOAT
                                                      60 Hz
                                                                                                                                                                                 PUMP
                                                                                                                             ON FLOAT

                                                                                                                    OFF FLOAT

Typical Simplex Installation                                                                                                     Typical Duplex Installation

                        TO ELECTRICAL                              SWING
 ACCESS                 CONTROLS OR                                CHECK                     SHUT-OFF
 COVER      VENT           OUTLET                                  VALVE                      VALVE                                          DUPLEX CONTROL SYSTEM
                                                                                                                                                                                  VENT                               CHECK   ISOLATION
                                                                                                                                                                                                                     VALVE     VALVE

                                                                                    DISCHARGE                                                                                                                          DISCHARGE
                                                                                                                                                                                        DISCHARGE

INLET
                                                                                                                                                                                                                          INLET

                                                                                                                                                                                                  3rd

                                                                                                                                                                                                        2nd

                                                                                                                                                                                                              1st

                                                                                                                                                                                                                    FLOAT SWITCH

 RECEIVER BASIN     SUBMERSIBLE                                   FLOAT
                  WASTEWATER PUMP                                SWITCH
10
TROUBLESHOOTING

  WARNING FAILURE TO DISCONNECT AND LOCKOUT ELECTRICAL
                POWER BEFORE ATTEMPTING ANY SERVICE CAN CAUSE
Hazardous       SHOCK, BURNS OR DEATH.
voltage

SYMPTOM                     PROBABLE CAUSE                        RECOMMENDED ACTION
MOTOR NOT RUNNING           Motor thermal protector tripped.      Allow motor to cool. Insure minimum pump

NOTE: If circuit breaker                                          submergence. Clear debris from casing and impeller.
“OPENS” repeatedly,         Open circuit breaker or blown fuse.   Determine cause, call a qualified electrician.
DO NOT reset. Call          Pump impeller binding or jammed.      Check motor amp draw. If two or more times higher
qualified electrician.
		                                                                than listed on pump nameplate, impeller is locked,
a) Manual operation         Power cable is damaged.               motor bearings or shaft is damaged. Clear
                            Inadequate electrical connection      debris from casing and impeller, consult with dealer.
                            in control panel.
		                                                                Resistance between power leads and ground should
b) Automatic operation      No neutral wire                       read infinity. If any reading is incorrect, call a
connected to control panel. qualified electrician.
                            Inadequate electrical connection      Inspect control panel wiring. Call a qualified
                            in control panel.                     electrician.
NOTE: Check the pump        Defective liquid level switch.        With switch disconnected, check continuity while
in manual mode first
		                                                                activating liquid level switch. Replace switch, as
to confirm operation. If
		                                                                required.
pump operates, the auto-
matic control or wiring is  Insufficient liquid level to          Allow liquid level to rise 3” to 4” (76 mm - 101 mm)
at fault. If pump does not activate controls.                     above turn-on level.
operate, see above.         Liquid level cords tangled.           Untangle cords and insure free operation.
PUMP WILL NOT                Liquid level cords tangled.          Untangle cords and insure free operation.
TURN OFF
  Pump is air locked.                                             Shut off pump for approximately one minute, then
		                                                                restart. Repeat until air lock clears. If air locking
		                                                                persists in a system with a check valve, a 3⁄16” (4.8 mm)
		                                                                hole may be drilled in the discharge pipe
		                                                                approximately 2” (51 mm) above the discharge
		                                                                connection.
  Influent flow is matching pump’s                                Larger pump may be required.
  discharge capacity.
LITTLE OR NO LIQUID          Check valve installed backwards,     Check flow arrow on valve and check valve
DELIVERED BY PUMP            plugged or stuck closed.             operation.
                             Excessive system head.               Consult with dealer.
                             Pump inlet plugged.                  Inspect and clear as required.
                             Improper voltage or wired            Check pump rotation, voltage and wiring.
                             incorrectly.                         Consult with qualified electrician.
                             Pump is air locked.                  See recommended action, above.
                             Impeller is worn or damaged.         Inspect impeller, replace as required.
                             Liquid level controls defective      Inspect, readjust or replace as required.
                             or improperly positioned.
PUMP CYCLES                  Discharge check valve inoperative.   Inspect, repair or replace as required.
CONSTANTLY                   Sewage containment area too small.   Consult with dealer.
                             Liquid level controls defective or   Inspect, readjust or replace as required.
                             improperly positioned.
                             Influent excessive for this size     Consult with dealer.
                             pump.

                                                                                                                           11
LIMITED CONSUMER WARRANTY
For goods sold for personal, family or household purposes, Seller warrants the goods purchased hereunder (with the exception of membranes,
seals, gaskets, elastomer materials, coatings and other “wear parts” or consumables all of which are not warranted except as otherwise provided
in the quotation or sales form) will be free from defects in material and workmanship for a period of one (1) year from the date of installation or
eighteen (18) months from the product date code, whichever shall occur first, unless a longer period is provided by law or is specified in the product
documentation (the “Warranty”).
Except as otherwise required by law, Seller shall, at its option and at no cost to Buyer, either repair or replace any product which fails to conform
with the Warranty provided Buyer gives written notice to Seller of any defects in material or workmanship within ten (10) days of the date when any
defects or non-conformance are first manifest. Under either repair or replacement option, Seller shall not be obligated to remove or pay for the
removal of the defective product or install or pay for the installation of the replaced or repaired product and Buyer shall be responsible for all other
costs, including, but not limited to, service costs, shipping fees and expenses. Seller shall have sole discretion as to the method or means of repair
or replacement. Buyer’s failure to comply with Seller’s repair or replacement directions shall terminate Seller’s obligations under this Warranty and
render this Warranty void. Any parts repaired or replaced under the Warranty are warranted only for the balance of the warranty period on the parts
that were repaired or replaced. The Warranty is conditioned on Buyer giving written notice to Seller of any defects in material or workmanship of
warranted goods within ten (10) days of the date when any defects are first manifest.
Seller shall have no warranty obligations to Buyer with respect to any product or parts of a product that have been: (a) repaired by third parties other
than Seller or without Seller’s written approval; (b) subject to misuse, misapplication, neglect, alteration, accident, or physical damage; (c) used in a
manner contrary to Seller’s instructions for installation, operation and maintenance; (d) damaged from ordinary wear and tear, corrosion, or chemical
attack; (e) damaged due to abnormal conditions, vibration, failure to properly prime, or operation without flow; (f) damaged due to a defective
power supply or improper electrical protection; or (g) damaged resulting from the use of accessory equipment not sold or approved by Seller. In
any case of products not manufactured by Seller, there is no warranty from Seller; however, Seller will extend to Buyer any warranty received from
Seller’s supplier of such products.
Goulds Water Technology Policy Concerning Online Sales to Consumers. Homeowners using the Internet to locate information regarding
residential water systems, residential wastewater systems, controls and tanks may discover several sites offering a direct-to-consumer purchasing
opportunity. Residential water and wastewater systems are mission critical applications and are designed to be installed by qualified professionals.
Goulds Water Technology has an extensive nationwide network of distributors and dealers, including authorized resellers. For a complete view of
Goulds Water Technology recognized distributors, dealers and authorized resellers, please refer to our locator at: http://goulds.com/sales-service/
No warranty is offered on Goulds Water Technology equipment purchased over the Internet, including web-based options from unauthorized
retailers. This policy is necessary to ensure that Goulds Water Technology equipment is installed properly, in compliance with applicable laws, rules
and codes, in a manner that addresses safety concerns and the proper performance of Goulds Water Technology equipment.
THE FOREGOING WARRANTY IS PROVIDED IN PLACE OF ALL OTHER EXPRESS WARRANTIES. ALL IMPLIED WARRANTIES, INCLUDING BUT
NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED TO ONE (1)
YEAR FROM THE DATE OF INSTALLATION OR EIGHTEEN (18) MONTHS FROM THE PRODUCT DATE CODE , WHICHEVER SHALL OCCUR FIRST.
EXCEPT AS OTHERWISE REQUIRED BY LAW, BUYER’S EXCLUSIVE REMEDY AND SELLER’S AGGREGATE LIABILITY FOR BREACH OF ANY OF THE
FOREGOING WARRANTIES ARE LIMITED TO REPAIRING OR REPLACING THE PRODUCT AND SHALL IN ALL CASES BE LIMITED TO THE AMOUNT
PAID BY THE BUYER FOR THE DEFECTIVE PRODUCT. IN NO EVENT SHALL SELLER BE LIABLE FOR ANY OTHER FORM OF DAMAGES, WHETHER
DIRECT, INDIRECT, LIQUIDATED, INCIDENTAL, CONSEQUENTIAL, PUNITIVE, EXEMPLARY OR SPECIAL DAMAGES, INCLUDING BUT NOT LIMITED
TO LOSS OF PROFIT, LOSS OF ANTICIPATED SAVINGS OR REVENUE, LOSS OF INCOME, LOSS OF BUSINESS, LOSS OF PRODUCTION, LOSS OF
OPPORTUNITY OR LOSS OF REPUTATION.
Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. Some states do not allow
the exclusion or limitation of incidental or consequential damages, so the above exclusions may not apply to you. This warranty gives you specific
legal rights, and you may also have other rights which may vary from state to state.
To make a warranty claim, check first with the dealer from whom you purchased the product or visit www.xyleminc.com for the name and location
of the nearest dealer providing warranty service.

                                         Xylem Inc.
                                         2881 East Bayard Street Ext., Suite A
                                         Seneca Falls, NY 13148
                                         Phone: (866) 673-0445
                                         Fax: (888) 322-5877
                                         www.xylem.com/goulds
                                         Goulds is a registered trademark of Goulds Pumps, Inc. and is used under license.
                                         © 2021 Xylem Inc.   IM127 Revision Number 8    March 2021
MANUAL DE INSTRUCCIÓN
                                                                IM127R08

Bombas Monofásicas
para sumidero, efluente y alcantarillado
INSTRUCCIONES DE INSTALACIÓN, FUNCIONAMIENTO Y MANTENIMIENTO
ÍNDICE
TEMA                                                                                                                                                                          PÁGINA
Instrucciones de seguridad................................................................................................................................................. 15
Verificaciones preliminares a la instalación....................................................................................................................... 15
Levantamiento de la bomba............................................................................................................................................... 16
Riel corredizo o sistema de levantamiento opcional....................................................................................................... 16
Tuberías.................................................................................................................................................................................. 16
Alambrado y conexión a tierra............................................................................................................................................ 16
Selección y cableado de los interruptores y paneles de control de la bomba............................................................ 17
Instalación en estanque sin los carriles de la diapositiva................................................................................................ 18
Instalación.............................................................................................................................................................................. 18
Operación.............................................................................................................................................................................. 19
Tabla del panel e interruptores de flotador...................................................................................................................... 20
Datos de ingeniería.............................................................................................................................................................. 21
Lecturas de resistencia de la instalación............................................................................................................................ 22
Instalaciones típicas y diagramas de cableado de la bomba de diseño simple.................................................... 22-23
Identificación y resolución de problemas......................................................................................................................... 24
Garantía limitada................................................................................................................................................................... 25

                   Información del propietario
Número de modelo de la bomba:

Número de serie de la bomba:

Número de modelo del control:

Agente:

No. telefónico del agente:
Fecha de compra:                                        Instalación:

Lecturas actuales en el momento de la puesta en marcha:
                                           1Ø
                           Amperios:
                           Voltios:

14
INSTRUCCIONES DE SEGURIDAD                                    estatales y provinciales. Las preguntas acerca del código
                                                              deben ser dirigidas al inspector eléctrico local. Si se hace
 PARA EVITAR LESIONES PERSONALES GRAVES O                     caso omiso a los códigos eléctricos y normas de seguri-
 AÚN FATALES Y SERIOS DAÑOS MATERIALES, LEA                   dad de OSHA, se pueden producir lesiones personales
 Y SIGA TODAS LAS INSTRUCCIONES DE SEGURI-                    o daños al equipo. Si se hace caso omiso a las instruc-
 DAD EN EL MANUAL Y EN LA BOMBA.                              ciones de instalación del fabricante, se puede producir
                                                              electrochoque, peligro de incendio, lesiones personales
 ESTE MANUAL HA SIDO CREADO COMO UNA                          o aún la muerte, daños al equipo, rendimiento insatisfac-
 GUÍA PARA LA INSTALACIÓN Y OPERACIÓN DE                      torio y podría anularse la garantía del fabricante.
 ESTA UNIDAD Y SE DEBE CONSERVAR JUNTO A LA
 BOMBA.                                                           ADVERTENCIA Los bombas no están diseñadas para us-
                                                                               arse en albercas, masas abiertas de agua,
                 Éste es un SÍMBOLO DE ALERTA DE              líquidos peligrosos o donde existan gases inflamables.
                 SEGURIDAD. Cuando vea este símbolo           Estos fluidos y gases podrían estar presentes en áreas
                 en la bomba o en el manual, busque           de contención. El tanque o pozo debe ser ventilado de
                 una de las siguientes palabras de señal y    acuerdo con los códigos locales.
                 esté alerta a la probabilidad de lesiones    En lugares con líquidos inflamables o donde pudiese
                 personales o daños materiales.               haber gases inflamables sólo deben usarse bombas
                                                              específica-mente clasificadas para áreas de Clase 1, Di-
    PELIGRO Advierte los peligros que CAUSARÁN                visión 1. Consulte los boletines de catálogos de bombas
            graves lesiones personales, la muerte o           específicas o la placa de identificación de la bomba con
            daños materiales mayores.                         respecto a las listas de agencias.
   ADVERTENCIA
                 Advierte los peligros que PUEDEN                 ADVERTENCIA Desconecte y bloquee la corriente eléc-
                 causar graves lesiones personales, la                         trica antes de instalar o dar servicio a cual-
                 muerte o daños materiales mayores.           quier equipo eléctrico. Muchas bombas están equipadas
                                                              con protección automática contra la sobrecarga térmica,
   PRECAUCIÓN    Advierte los peligros que PUEDEN             la cual podría permitir que una bomba demasiado cali-
                 causar lesiones personales o daños           ente rearranque inesperadamente.
                 materiales.
 AVISO: INDICA INSTRUCCIONES ESPECIALES QUE                   INFORMACIÓN IMPORTANTE DE
 SON MUY IMPORTANTES Y QUE SE DEBEN SE-                       PREINSTALACIÓN
 GUIR.                                                             La bomba debe conectarse a un circuito eléctrico
 EXAMINE BIEN TODAS LAS INSTRUCCIONES Y                            dedicado protegido con un cortacircuitos o fusible
 ADVERTENCIAS ANTES DE REALIZAR CUALQUIER                          del tamaño apropiado. Instale un desconectador cu-
 TRABAJO EN ESTA BOMBA.                                            ando el código así lo requiera. Las preguntas acerca
                                                                   del código deben ser dirigidas al inspector eléctrico.
 MANTENGA TODAS LAS CALCOMANÍAS DE SE-
                                                                   Las bombas y flotadores equipados con un enchufe
 GURIDAD.
                                                                   de 3 clavijas conectado a tierra deben enchufarse a
  ADVERTENCIA    Ninguna persona que tenga capacidades             un receptáculo trifilar. No conecte a extensiones o
                 físicas, sensoriales o mentales reducidas         conectores sin un enchufe de 3 clavijas conectado a
(tampoco niños) o a la que le falten experiencia y cono-           tierra. NOTA: La eliminación del enchufe del cable
cimientos (a no ser que tenga supervisión o instrucción            eléctrico no es permisible por código del NEC.
en relación con el uso de la bomba por parte de una per-           La eliminación del enchufe anulará el listado de la
sona responsable por su seguridad). Debe supervisarse a            agencia.
los niños para asegurar que no jueguen con la bomba.
                                                                PRECAUCIÓN Esta bomba ha sido evaluada solo para
    ADVERTENCIA Riesgo de descarga eléctrica. Esta bomba                     uso con agua.
                 tiene un conductor de conexión a tierra
y un enchufe de conexión tipo conexión a tierra. Para           ADVERTENCIA Riesgo de descarga eléctrica – esta
reducir el riesgo de descarga eléctrica, instale solo en un                   bomba está provista con un conductor de
circuito protegido por un interruptor de circuito para fal-        conexión a tierra y enchufe accesorio del tipo para
las a tierra (GFCI) con una corriente de disparo nominal           conexión a tierra. Para reducir el riesgo de descarga
de no más de 30 mA.                                                eléctrica, asegúrese de que sea conectado única-
                                                                   mente a un receptáculo del tipo para conexión a
    ADVERTENCIA Esta unidad contiene aceite lubricante.
                 Implemente siempre las medidas necesar-           tierra, correctamente conectado a tierra.
ias para asegurar que cualquier lubricante vertido no se        ADVERTENCIA Este puede exponerlo a químicos,
disperse en el medio ambiente. Está prohibido eliminar                        incluido el plomo y Phthalate (DINP),
líquidos lubricantes en el medio ambiente.                         reconocidos por el estado de California por
    ADVERTENCIA Si el cable de suministro está dañado, solo        provocar cáncer y defectos del nacimiento u otros
                 puede ser reemplazado por personas ex-            daños reproductivos. Para obtener más
pertas y cualificadas para evitar peligros. Use solo piezas        información, acceda a: www.P65Warnings.ca.gov.
de repuesto originales para reemplazar componentes            INFORMACIÓN GENERAL
defectuosos. Las piezas de repuesto inadecuadas pueden
provocar el funcionamiento incorrecto del producto y          Las bombas para sumidero están diseñadas para funcio-
pueden causar peligros para las personas y los bienes.        nar intermitentemente y habitualmente por temporadas.
                                                              Se recomienda que pruebe la bomba antes del comien-
    ADVERTENCIA Todo el trabajo eléctrico debe ser realiza-   zo de la estación lluviosa para asegurar que la bomba y
                 do por un técnico calificado. Siempre siga
                                                              el interruptor estén funcionando correctamente.
el Código Eléctrico de EE.UU. (NEC) o el Código Eléc-
trico Canadiense, además de todos los códigos locales,
                                                                                                                          15
Sugerimos instalar un sistema de alarma por alto nivel de        Levante la bomba con una cadena o cable de tamaño
agua y un sistema de bomba de reserva a batería para             adecuado conectado al perno de ojo de levantamiento.
sótanos habitables o áreas donde la inundación podría            NO dañe los cables eléctricos o de los sensores al subir y
causar daños materiales. Un generador de reserva es              bajar la unidad.
otra opción que puede consultar con el instalador de             RIEL CORREDIZO O SISTEMA DE
la bomba. La mayoría de los cortes eléctricos ocurren            LEVANTAMIENTO OPCIONAL
durante temporales de lluvia, justo cuando necesita más
su bomba para sumidero. Las garantías del fabricante de          En muchos estanques de efluente y aguas negras o
la bomba sólo cubren la bomba. La mano de obra y los             estaciones de levantamiento se recomienda instalar
daños y perjuicios imprevistos, tales como inundaciones,         la bomba en un sistema de riel corredizo o sobre un
no están cubiertos.                                              adaptador de levantamiento para facilitar la instalación
                                                                 y retiro para inspección y/o servicio. La mayoría de los
VERIFICACIONES PRELIMINARES                                      códigos no permite que el personal entre al pozo sin el
A LA INSTALACIÓN                                                 equipo de protección y la capacitación correctos. Los
Abra todas las cajas e inspeccione el equipo para deter-         rieles corredizos están diseñados para facilitar el retiro de
minar si se ocasionaron daños durante el envío. Notifique        la bomba sin necesidad de entrar al pozo o perturbar la
cualquier daño a su proveedor o a la compañía de trans-          tubería. El riel corredizo o el adaptador de levantamiento
porte de inmediato.                                              debe situar la bomba opuesta a la abertura para el
Importante: Siempre verifique que las clasificaciones de         líquido de entrada, evitando las áreas estancadas donde
corriente, tensión, fase y potencia en la placa de identifi-     pudiesen asentarse sólidos. El estanque o fosa debe
cación de la bomba correspondan con las del panel de             ser capaz de soportar el peso de la bomba y del riel de
control y fuente de alimentación.                                deslizamiento. El piso de la fosa debe ser plano.
Muchas de nuestras bombas para alcantarillado están              AVISO: SIGA LAS INSTRUCCIONES INCLUIDAS CON EL
llenas con aceite. Si hay alguna señal de fuga de aceite                   CONJUNTO DEL RIEL CORREDIZO.
o si la unidad estuvo almacenada durante largo tiempo,           TUBERÍAS
verifique el nivel de aceite en la cúpula del motor y la
                                                                 La tubería de descarga no debe ser más pequeña que el
caja del sello, en caso de haberla.
                                                                 diámetro de descarga de la bomba y debe mantenerse
Verifique el nivel de aceite de la cubierta del motor a          lo más corta posible, evitando los accesorios innecesa-
través del tapón de la tubería en el extremo superior de         rios para reducir al mínimo las pérdidas por fricción.
la unidad. El aceite en la cámara del motor debe cubrir
                                                                 Instale una válvula de retención de tamaño adecuado
apenas el motor. ¡No llene en exceso, deje espacio para
                                                                 que corresponda con la capacidad de manejo de sólidos
expansión!
                                                                 de la bomba para evitar el contraflujo de fluido. El con-
Si el nivel está bajo, agregue aceite para turbinas ASTM         traflujo puede hacer que la bomba “gire” en dirección
150. Reinstale el tapón.                                         inversa, produciendo un desgaste prematuro del sello
Puede obtenerse aceite en latas de 5 galones de                  y/o del cojinete. Si la bomba gira en sentido inverso al
nuestros distribuidores. También puede obtener aceite            arrancar, el aumento de torsión puede dañar el motor
a nivel local en talleres de reparación de motores. Las          y/o el eje del motor de la bomba y algunas bombas
marcas típicas de aceite son: Shell Turbo 32, Sunoco             monofásicas hasta podrían funcionar en sentido inverso.
Sunvis 932, Texaco Regal R&O 32, Exxon Nuto 32 y Mobil           Instale una válvula de compuerta de tamaño adecuado
DTE Light.                                                       DESPUÉS de la válvula de retención para facilitar el
Inspeccione la tuerca de alivio de tensión en los conjun-        mantenimiento de la bomba, las tuberías y la válvula de
tos de protección contra tirones de los cables de aliment-       retención.
ación. Torsión de los cables de alimentación: 75 pulg.-lbs.      Importante – antes de instalar la bomba. Si se va a
para cables #16 y 80 pulg.-lbs. para todos los otros tipos       bombear agua, perfore un orificio de alivio de 1⁄8 pulg.
de cable.                                                        (3.2 mm). Si se va a bombear agua residual con sólidos,
La garantía no cubre daños causados por conectar bom-            perfore un orificio de alivio de 3⁄16 pulg. (4.8 mm) en la
bas y controles a la fuente de energía incorrecta (fuente        tubería de descarga. Debe situarse dentro del pozo, a
de tensión/fase).                                                2 pulg. (51 mm) sobre la descarga de la bomba, pero
Anote los números de modelos y números de serie de               debajo de la válvula de retención. El orificio de alivio per-
las bombas y del panel de control en la sección delantera        mite el escape de aire de la carcasa. Al permitir que entre
de este manual de instrucciones para referencia futura.          líquido a la carcasa se asegura que la bomba pueda ar-
Entregue el manual al propietario o adjúntelo al panel de        rancar cuando el nivel de líquido aumente. A menos que
control una vez finalizada la instalación.                       se proporcione un orificio de alivio, una bomba de toma
                                                                 inferior podría “obstruirse con aire” y no bombear agua,
LEVANTAMIENTO DE LA BOMBA                                        a pesar de que el impulsor gire.
     ADVERTENCIA              NO LEVANTE NI TRANSPORTE NI        Todas las tuberías deben estar apoyadas correctamente,
                              CUELGUE LA BOMBA DE LOS CABLES     de modo que no se apliquen esfuerzos o cargas de las
                              ELÉCTRICOS. EL DAÑO A LOS CABLES   tuberías a la bomba.
                              ELÉCTRICOS PUEDE PRODUCIR
                              ELECTROCHOQUE, QUEMADURAS O        La cubierta de acceso a la fosa debe ser de tamaño
                              AÚN LA MUERTE.                     suficiente para permitir realizar el servicio de inspección,
                                                                 mantenimiento y levantamiento con grúa o montacargas.
Un voltaje peligroso puede
producir golpes eléctricos,
quemaduras o la muerte.

16
ALAMBRADO y CONEXIÓN A TIERRA                                  Los interruptores de flotador de ángulo amplio son el
Aviso importante: Lea las instrucciones de seguridad           tipo más popular. Pueden conectarse directamente a una
antes de proseguir con el cableado.                            bomba o a un panel de control. El “largo de la traba” o
                                                               la distancia entre el cuerpo del interruptor y el punto de
       Use únicamente alambre trenzado de cobre para
                                                               pivote controla los puntos de encendido y apagado y la
       la bomba/motor y la conexión a tierra. El alambre
                                                               cantidad bombeada en un ciclo. El punto de pivote es
       de conexión a tierra debe ser al menos del mismo
                                                               donde el flotador va conectado ya sea a la bomba o a la
       tamaño que los alambres de la fuente de aliment-
                                                               tubería de descarga. Consulte las figuras 1 a 5.
       ación. Los alambres deben codificarse con colores
       para facilitar el mantenimiento y la identificación y   INSTALACIÓN DE LOS INTERRUPTORES
       resolución de problemas.                                DE FLOTADOR
                                                               No hay reglas absolutas acerca de dónde instalar los
       Instale los cables y la conexión a tierra de acuerdo
                                                               interruptores de flotador, varía de trabajo a trabajo.
       con el Código Eléctrico de EE.UU. (NEC) o el
       Código Eléctrico Canadiense, además de los              Reglas sugeridas a seguir: ¡Todos los flotadores de-
       códigos locales, estatales y provinciales.              ben instalarse debajo de la tubería de entrada!
       Instale un desconectador de todos los circuitos         Flotador de apagado: Primera preferencia: instálelo
       donde el código lo requiera.                            de manera que el nivel del agua quede siempre sobre
                                                               el extremo superior de la bomba (cúpula del motor). Se-
       Desconecte y bloquee la corriente eléctrica antes
                                                               gunda preferencia: instálelo de manera que el nivel del
       de instalar o dar servicio.
                                                               agua quede a no más de 6 pulg. por debajo del extremo
       La tensión y fase de la fuente de alimentación          superior de la bomba.
       debe corresponder con todos los requerimientos
                                                               Flotador de encendido: instálelo de manera que el
       del equipo. La tensión o fase incorrecta puede
                                                               volumen de agua entre los flotadores de encendido y
       producir incendio, daño al motor o a los controles
                                                               apagado permita bombas de 1½ HP y menores funcio-
       y anula la garantía.
                                                               nar al menos 1 minuto. Las bombas de dos (2) HP y may-
       Todos los empalmes debe ser impermeables. Si            ores deben funcionar al menos 2 minutos. La literatura
       utiliza juegos de empalme, siga las instrucciones       sobre estanques establece los galones de almacenaje
       del fabricante.                                         por pulgada de altura del estanque.
   ADVERTENCIA Seleccione una caja de conexiones               Flotador(es) de retardo/alarma: deben escalonarse
                  NEMA del tipo correcto para la               sobre los flotadores de apagado y encendido. Trate de
                  aplicación y ubicación. La caja de           utilizar la mayoría del almacenaje disponible ofrecido
                  conexiones debe garantizar conexiones        por el estanque, ahorre espacio para la capacidad de
                  de cableado seguras y secas.                 almacenaje de reserva. Consulte los diagramas y tablas
   ADVERTENCIA Selle todos los controles de los gases          en la Sección de Tablas de Interruptores de Flotador.
                  presentes que pudiesen dañar los             DIAGRAMAS DE CABLEADO DEL PANEL
                  componentes eléctricos.                      Nuestros paneles de control se envían con instrucciones
  ADVERTENCIA
                  LA FALLA DE CONECTAR A TIERRA                y diagramas de cableado. Utilice dichas instrucciones
                  PERMANENTEMENTE LA BOMBA, EL                 en conjunto con este manual de instrucciones (IOM).
 Tensión          MOTOR Y LOS CONTROLES, ANTES                 La instalación eléctrica debe ser realizada por técnicos
 peligrosa                                                     calificados únicamente. Cualquier problema o preguntas
                  DE CONECTAR LA CORRIENTE
                  ELÉCTRICA PUEDE CAUSAR                       con respecto al control de otras marcas debe dirigirse a
                  ELECTROCHOQUE, QUEMADURAS O                  ese proveedor o al fabricante del control. Nuestro per-
                  LA MUERTE.                                   sonal técnico no tiene diagramas esquemáticos técnicos
SELECCIÓN Y CABLEADO DE LOS                                    o información de identificación y resolución de prob-
                                                               lemas de los controles de otras compañías.
INTERRUPTORES Y PANELES DE
CONTROL DE LA BOMBA                                            ALARMAS
                                                               Recomendamos la instalación de una alarma en todas
TIPOS DE INTERRUPTORES DE FLOTADOR
                                                               las bombas para aguas residuales. Muchos paneles
Hay tres tipos de interruptores de flotador de uso típico
                                                               de control estándar vienen equipados con circuitos de
en las bombas monofásicas: de acción simple, vertical y
                                                               alarma. Si no se usa un panel de control, se ofrece una
de ángulo amplio.
                                                               alarma por alto nivel de líquido independiente. La alarma
Los interruptores de control de acción simple, sólo            alerta al propietario acerca de una situación de alto nivel
pueden conectarse a través de un panel de control. Si          de líquido en el sistema, de manera que pueda comu-
se conectan directamente a una bomba, se producirá             nicarse con el personal de servicio apropiado para que
un ciclado rápido y se podría quemar el motor y/o el           investigue la situación.
interruptor de arranque del motor y/o el interruptor de
                                                               BOMBAS MONOFÁSICAS
flotador. Si se utilizan interruptores de acción simple con
                                                               Las bombas monofásicas (1Ø) pueden operarse utilizan-
un panel de control, consulte la Sección del Panel e Inter-
                                                               do un interruptor de flotador en tándem o de conexión
ruptor de flotador.
                                                               directa, un contactador o un panel de control simple o
Se ofrecen interruptores de flotador mecánicos verticales      doble. Ver las Figuras 1, 2 y 5.
con enchufes en tándem para las bombas monofásicas.
                                                               Todas las bombas del 1/3 y ½ HP, de 115 ó 230 voltios y
Son una selección ideal cuando hay espacio limitado
                                                               algunas bombas de ¾ y de 1 HP están equipadas con
para un interruptor. Requieren menos espacio que un
                                                               cables de alimentación estilo enchufe. Pueden enchu-
interruptor de ángulo amplio ya que viajan en dirección
                                                               farse a interruptores de flotador en tándem para instala-
vertical. Los números de modelos típicos comienzan con
                                                               ciones sencillas. Se permite quitar los enchufes para co-
A2H ...
                                                               nectar directamente o conectar a un controlador simple
                                                                                                                        17
You can also read