Improve the quality of your life! In regions where the ambient temperature often exceeds 45ºC (= 115ºF), the cold water used for showering can reach more than 40ºC. Therefore it significantly improves the quality of life to have a large reservoir of cold water for this purpose. ECOBUILD shower water chillers are the best choice for this demand. Manufactured in Europe, the chillers meet highest quality standards, ensure reliable and easy operation and sup- ply a large amount of cold water using minimum energy. 100% renewable energy The energy demand for ECOBUILD shower water chillers is below 500W. Therefore the main source of energy can be a small photovoltaic systems existing of only two panels. Thus your comfortable cool shower experience can be supplied by 100 percent renewable energy – to improve the quality of your life – and to save valuable energy resources. Photo: Shutterstock/ Micimakin Applications • Showers • Spas • Pools • Baths • Cold plunges • Eye wash 2
Advantages of the ECOBUILD Shower Water Chiller Low Energy Optional: 100% Consumption Renewable Energy approx. 500W by photovoltaic Low Price Easy Installation top price-performance ratio pre-assembled unit Designed for high Small Foot Print ambient temperature up to 50ºC < 0.5 m2 Large amount Highest Quality of cold water in 24h >500 litres at 15ºC from Europe Plug-and-Play unit including: Heat pump Storage tank Controller 3
Low Energy Easy Installation: Consumption plug-and-play At an ambient temperature The ECOBUILD Shower of approx. 50ºC, water at Water Chiller is a pre- 40ºC can be cooled down assembled plug-and-play to 15ºC with less than unit, which can be installed 500W. easily. 100% Renewable Energy Using a small photovoltaic system (only two panels), the necessary 500W can ea- sily be supplied by the power of the sun (optional). Designed for high ambient temperature In regions with high ambient temperatures (up to 50ºC), the “cold water” often YOUR reaches more than 40ºC. It is necessary to cool it down for showering. 4
Small Foot Print Low Price The unit needs less than One ECOBUILD Shower 0.5 m2 in the plant room of Water Chiller costs only e. g. a villa – minimal floor EUR 1,990*). And you save space for a maximum of operation costs due to the cold water. low energy demand. Highest Quality The unit is manufactured in Europe and therefore meets highest quality standards – for a reliable operation and a long life-time. Large amount of cold water in 24h With a storage volume of 266 litres more than 500 BENEFITS litres of cold water at 15ºC can be supplied within 24 hours. 5
Optional: Powered by Solar PV The sun rays excite electrons and therefore only the balance of inside the solar photovoltaic consumed electricity is invoiced. panels, which create DC electric current. An DC/AC inverter con- Minimum roof space verts the DC power into standard Since the ECOBUILD Sho- household AC power for use in wer Water Chiller only needs the home, synchronizing with uti- 500 W, two standard photovol- lity power whenever the electri- taic panels are enough to supply cal grid is distributing electricity. this necessary power. The utility power is automatically provided The produced photovoltaic at night and also during day time electricity, that is not used in when the demand exceeds the the household can be feeded solar power production. into the public grid (if available) or used for other consumers in the villa. Each kWh is credited 6
ECOBUILD Hot Water Heat Pump: Reduce Electrical Connection Power - up to 92% Electrical Consumption - up to 72% Conventional design for hot water generation: several electric water heaters For a regular villa for one family usually up to 4 electric water heaters are mounted in several bathrooms as well as in the kitchen for hot water preparation. Each of these units has Regular Design: an electric heating element with 1.5 8 kW electrical to 2 kW, some of them operating several times a day. Therefore one connection power villa needs in average about 9 kWh for the hot water generation. approx. 9.0 kWh per day *) ECOBUILD design for hot water generation: one central unit The ECOBUILD Hot Water Heat Pump requires only 0.5 kW elec- ECOBUILD Design: trical power. One unit can usually 0.5kW electrical provide enough hot water for a connection power regular villa. In average one unit needs 2.6 kWh capacity per day. approx. 2.6 kWh per day*) 7 *) Calculations are based upon 230 litres of 60ºC hot water per day.
ECOBUILD Shower Water Chiller SCHP 395 Technical Data Dimensions: H: 1768mm, Ø 707mm Weight without packaging: 145 kg Voltage / Frequency: 230 V / 50 Hz Phase-Neutral-Earth Heat pump input: 395 Watt Heat pump output: 1200 Watt High supplementary heating: 2000 Watt / 230 V Refrigent: R134a Quantity of air: Min. / Max. 200 / 300 m3/h Air temperature: Min. – 10ºC to Max. +45ºCW Cold water storage tank: Enamelled, 266 litres (optional: stainless steel) Working pressure: Max. 1 MPa / 10 bar Anode: Magnesium – 5/4'' RG Water temperature: Adjustable - Min. 13ºC Cold water output: 504 litres at 15ºC / 24h Water connections • Cold water: 1'' RT • Hot water: 1'' RT • Condensdation water: 1/2'' RT • Heat exchanger: 1'' RT • Circulation connection: 3/4'' RT Electronic: Yes Air inlet / outlet: Top / Top Duct connection: Ø 160 mm Customer Support: ECOBUILD-e ECOBUILD – a brand of ECOTHERM Austria 2019_FLY_ECOBUILD ECOBUILD Kuwait Al Thuwaini Fahad Al-Salem St. Kuwait City www.ecobuild-smartbuildingcomponents.jimdo.com © Copyright ECOBUILD, all rights reserved. We reserve the right to make alterations.