SKYLIGHTS TECHNICAL FILE Skymax CE ® Smoke and Heat Extraction system for staircases Conformity with NBN S21-208-3 01-09-2021
with plastic skylight with flat roof window or iDome with plastic skylight Skylux iWindow2/iWindow3 Skymax CE Skymax CE General product description The Skymax® CE dome exists of: - A synthetic Skylux® dome* in acrylic or polycarbonate, composed according to the Skylux® specifications or a Skylux® iWindow2 or iWindow3 glass dome (see price list for available sizes) - A curb in PVC (type 16/00, 20/00 EP or 30/20) or metal (type M30, M40, ...), which is part of the CE agreement of the SHEV system (see page 3) (PVC 16/00: only with a plastic skylight) - A PVC frame (standard ST) for the synthetic dome or with a PVC frame with glass or an EP25 sheet (for Skylux® iDome hybrid dome), which is part of the CE certification (for Skymax iDome, maximum double-walled skylight, depending on the snow load) - External support sheets with accessories for PVC curbs - An opening system with two 24 Volt actuators Complementary: - One central detection unit type Skycom® Skymax CE - A priority switch Advantages - Free access to the roof - Exceptional insulation (Ut** value up to 0.50 W/m².K) - Air permeability class 2 according to EN 1873:2014+A1:2016 - RW value up to 40 dB, in case of a Skylux iDome or Skylux iWindow2 or iWindow3 - 100 % thermal break - Skylux® quick-mount concept - Easy installation - CE approved according to EN 12101-2 - According to NBN S21-208-3 * Skylux® domes have a CE agreement according to EN 1873:2014+A1:2016 ** Ut: U (transparant) or insulation value of the Skylux® dome according to EN 1873:2014+A1:2016, determined in accordance with EN 673 2/4 E_TD_TECHNICAL_FILE_SKYLUX_SKYMAX_CE 01-09-2021
CE specifications according to EN 12101-2 for Skymax® CE Time until full opening........................................................ < 60 sec Min. functioning temperature (°C)....................... -15 °C Heat resistance (°C).............................................................. B300 Snow load (N/m²)...................................................................... SL 300 to SL 900 Wind load (N/m²)...................................................................... WL 1500 Reliability class SHE.............................................................. Re 1000 Durability.......................................................................................... Re 10.000 Maximum slope.......................................................................... 10° * always ask for the aerodynamic coefficient determined by lateral wind ** see technical table in addendum, for possible snow loads Product description actuator The Skymax® CE is a dome for smoke and heat extraction equipped with a daily ventilation function and roof access. On alarm, the dome fully opens diagonally away from the upstand (see pict.) The two actuators are equipped with an electric final course, which states the maximum course of the actuator on opening and closing. For rectangular domes, the actuators and the opening system are fixed on the long sides. The Skymax® CE opens on the long sides. Specific characteristics opening mechanism Tension................................................................................................ 24 V DC - 48 V DC Current............................................................................................... nominal 5 A (per system) at 24 V Opening angle............................................................................. entirely (180°) Final course.................................................................................... electronic Density................................................................................................ IP 54 Certification................................................................................. CE volgens EN 12101-2 Execution mechanism......................................................... galvanised Execution housing................................................................... powder-coated white Product description central detection unit The Skymax® CE is operated by a Skycom® Skymax CE central detection unit and a built-in heat detector (75°C). This detection unit is equipped with several connection possibilities. The detection unit has an autonomy of at least 72h with tension due the incorporated batteries. The central detection unit must be equipped with a priority switch to operate the SHE system in case of emergency. Remark To avoid heat build-up under the transparent skylight (plastic, hybrid, glass) and therefore possible deformation or damage to the PVC curb, frame, skylight dome or electrical components, it is recommended that no closed surface (e.g. black closed attic hatch) is installed under the skylights. A reflective (e.g. white) surface and/or ventilation is recommended. 3/4 01-09-2021 E_TD_TECHNICAL_FILE_SKYLUX_SKYMAX_CE
REVISION HISTORY Curb combinations REV DESCRIPTION SKYMAX CE ELECTRIC 16-00 OPEN REV DESCRIPTION DATE APPROVED SKYMAX CE ELECTRIC M30 OPEN Skylux dome Skylux dome 1 dome 1 dome 2 curb 2 curb 3 frame 3 frame 4 actua 4 actuator right 5 actua 5 actuator left 6 supporting plate SECTION A-A SECTION A-A with PVC curb 16/00 or 20/00 cross section with 1PVC curb 30/20 Lacquered Surface: with metal curb crossM30 section or higher min 300 mm total height Material Density kg/m³ Mass kg Anodisation Surface mm² Revision File name 3 State Title Designer 3 Sizes and opening direction Date Created 23/05/2018 Artn° Ext. Artn° F140 E860 Tolerances Last modification on 2/10/2018 By CHVV cable F 140connection E 860 G 590 Scale 1:50 Format A3 Sheet 1/1 (final course) G 590 B 1000 B' 1000 B 1000 B' 2 D300 4 D 300 4 6 max. 6 5 opening direction C 1000 C' C 1000 875 mm C' 1000 650 mm front view side view front view side 900 mm SECTION B-B 100 100 SCALE 1 : 10 840 843 Attestations, A certificates A and documentation A B B A perspectiv top view •PVCConformity withC top NBN view S21-208-3 Material Material Density 16-00 B B' C' D E F G Density M30 B B' C C' D E F G Mass 0,000 kg •100CE x 100 of1000 the 1000 Skylux1000 dome ® 1000 according 300 860 to EN 140 590 1873:2014+A1:2016 0,000 kg Mass 0,00 dm^3 Volume 100 x 100 80 x 130 1000 800 1000 1300 1000 800 1000 1300 300 300 860 860 140 -60 590 590 Volume Surface 0,00 dm^3 80 x 130 800 1300 800 1300 300 860 -60 590 •90 xCE 120 of900the 1200 SHE system 1200 according to40EN 590 12.101-2 Surface FILE NAME: Skymax 1600 open Skylux dome.dft Ixx 0,000000 kg.mm 900 300 860 0,000000 kg.mm^2 Ixx TITLE:90 x 120 900 1200 900 1200 300 860 40 590 Designer tods tods Designer 1 120 x 120 1200 1200 1200 1200 300 860 340 590 Date 2/04/2014 •120Attestation x 120 1200 1200 1200 1200 Joule 1200 fall 300 through 860 340 protection 590 for armoured dome with polycarbonate shell, SB 1200 (EN 2/04/2014 Date A2 1 UNLESS OTHERWISE SPECIFIED DIMEN ARE IN MILLIMETERS Last modification on 23/06/2014 UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN MILLIMETERS ANGLES ±X.X° 2 PL ±X.XX 3 PL ±X aansluiting bekabeling SCALE: SHEET 1 OF 1 ANGLES ±X.X° 2 PL ±X.XX 3 PL ±X.XXX 1873:2014+2016) for iDome with armoured dome, iWindow2, iWindow3 (eindekoers) • Attestation for 72h autonomy with Skycom® Skymax CE central detection unit • DoP via www.skylux.be • Fall-through safety certificate DIN 18008-6 for Skylux iDome, Skylux iWindow2 or iWindow3, in combination with all Skylux PVC, polyester or metal curbs, for all sizes. Additionally, there is residual load-bearing capacity after breakage for sizes ≤ 120x120 cm and ≤ 100x300 cm in accordance with DIN 18008-6. Fire classification • Fire classification Skylux® domes Acrylic dome : Euroclass E (EN 13501-1) Polycarbonate dome : Euroclass B-s1, d0 (EN 13501-1) • Fire classification PVC curbs : Euroclass E (EN 13501-1) Attention: the CE certification is only valid if the composition, execution and the installation regulations are respected. SKYLUX guarantees the CE conformity as described in the documentation and according the plant regulations of the appliances. Every variance, cancels the CE conformity. ONLY USE ORIGINAL PARTS DELIVERED BY SKYLUX. EVERY GUARANTEE IS CANCELLED IF NON-ORIGINAL PARTS ARE USED. THE SHE DETECTION UNIT MUST BE USED WITH THE RIGHT SHE OPENING SYSTEM. THE USE OF NON-ORIGINAL SHE PARTS CAN LEAD TO DEFECTS OF THE SYSTEM. SKYLUX NV SPINNERIJSTRAAT 100 - B-8530 STASEGEM T +32 (0)56 20 00 00 - F +32 (0)56 21 95 99 INFO@SKYLUX.BE WWW.SKYLUX.BE 4/4 E_TD_TECHNICAL_FILE_SKYLUX_SKYMAX_CE 01-09-2021
You can also read