Owner’s Instruction and Operation Manual Model Number: VG3200-P R Report Number: F20-586 Tested Per EPA Methods ALT-125, ASTM E2515, ASTM E3053 and CSA B415 Certified to UL 1482-2011 (R2015) and ULC-S627-00-REV1 Approved for mobile home installation in (USA ONLY) * All Pictures In This Manual Are For Illustrative Purposes Only. Actual Product May Vary. 853745E-1805K Save These Instructions In A Safe Place For Future Reference. SAFETY NOTICE: If this heater is not properly installed, a house fire may result. For your safety, follow the installation instructions. Never use make-shift compromises during the installation of this heater. Contact local building or fire officials about permits, restrictions and installation requirements in your area. NEVER OPERATE THIS PRODUCT WHILE UNATTENDED. CAUTION! Please read this entire manual before you install or use your new room heater. Failure to follow instructions may result in property damage, bodily injury, or even death. Improper Installation Will Void Your Warranty! U.S. Environmental Protection Agency CALIFORNIA PROPOSITION 65 WARNING: This product can expose you to chemicals Certified to comply with 2020 particulate including carbon monoxide, which is known to the State of California to cause cancer, birth defects, emissions standards. and/or other reproductive harm. For more information, go to www.P65warnings.ca.gov THIS MANUAL IS SUBJECT TO CHANGE WITHOUT NOTICE. © 2021 United States Stove Company, 227 Industrial Park Rd., South Pittsburg, TN 37380 Ph. 800-750-2723
INTRODUCTION The instructions pertaining to the installation of your wood stove comply with UL-1482 (R2015) and ULC-S627 standards. This manual describes the installation and operation of the Vogelzang, VG3200 wood heater. This heater meets the 2020 U.S. Environmental Protection Agency’s cordwood emission limits for wood heaters sold after May 15, 2020. Under specific test conditions this heater has been shown to deliver heat at rates ranging from 19,778 to 67,992 Btu/hr with 1.3 g/hr and 71% efficiency. Note: The BTU ratings mentioned above are based on the EPA test protocol under specific test conditions. Our advertised BTU’s are based on the first hour of operation at high burn rate burning cordwood. Combustible: Wood Colors: Black Flue Pipe Diameter: 6” (153 mm) Flue Pipe Type: Black or Blued Steel 2100°F (650°C) Minimum Chimney Height: 12’ (3.7 m) Maximum Log Length: 18” (458 mm) Electrical: 120VAC, 0.55A, 60Hz Dimensions DEPTH WIDTH HEIGHT Overall: Depth x Width x Height: 39” (995 mm) 24” (612 mm) 32-1/2” (826 mm) Combustion Chamber: Width x Depth: 18-5/16” X 22-1/4” (466 mm X 565 mm) Door Opening: Width x Height: 14-3/4” 9-7/16” (375 mm X 241 mm) Pyroceramic Glass Door: (Viewing) Width x Height: 14-9/16” X 9-5/16” (369 mm X 237 mm) CAUTIONS: • HOT WHILE IN OPERATION. KEEP CHILDREN, CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSE SKIN BURNS. • DO NOT USE CHEMICALS OR FLUIDS TO IGNITE THE FIRE. • DO NOT LEAVE THE STOVE UNATTENDED WHEN THE DOOR IS SLIGHTLY OPENED. • DO NOT BURN GARBAGE, FLAMMABLE FLUID SUCH AS GASOLINE, NAPHTHA OR MOTOR OIL. • DO NOT CONNECT TO ANY AIR DISTRIBUTION DUCT OR SYSTEM. • ALWAYS CLOSE THE DOOR AFTER THE IGNITION. Note: Register your product online at For Customer Service, please call: www.usstove.com or download the free 1-800-750-2723 Ext 5050 or; app today. This app is available only Text to 423-301-5624 or; on the App Store for iPhone and iPad. Email us at: Search US Stove. Save your receipt with your records for any claims. customerservice@usstove.com 2 © 2021 United States Stove Company
INSTALLATION CHECKLIST Your Wood Stove should be installed by a qualified installer only. An NFI qualified Installer can be found at www.nficertified. org/public/find-an-nfi-pro/ CUSTOMER SERVICE 1-800-750-2723 ext 5050 Text to 423-301-5624 Email to: Customerservice@usstove.com COMMISSIONING CHECKLIST This Checklist is to be completed in full by the qualified person who installs this unit. Keep this page for future reference. Failure to install and commission according to the manufacturer’s instructions and complete this checklist will invalidate the warranty. Please Print Customer Name: Telephone Number: Address: Model: Serial Number: Installation Company Name: Phone Number: Installation Technician’s Name: License Number: DESCRIPTION OF WORK Location of installed appliance: ______________________________________________________________________________________ Chimney System: New Chimney System Yes No If yes, Brand_____________________________________________ If no, Date of inspection of the existing chimney system:_______________________________________________________________ COMMISSIONING Confirm Hearth Pad Installation as per Installation Instructions.......................................................................................... Confirm proper placement of internal parts............................................................................................................................ Check soundness of door gasket and door seals.................................................................................................................. Confirm clearances to combustibles as per installation instructions in this manual.......................................................... Check the operations of the air controls................................................................................................................................. Confirm all flue pipe and chimney system are secure and sealed........................................................................................ Confirm the stove properly drafts when fired.......................................................................................................................... Check to ensure a CO alarm is installed as per local building codes and is functional....................................................... Explain the safe operation, proper fuel usage, cleaning, and routine maintenance requirements...................................... Declaration of Completion: As the qualified person responsible for the work described above, I confirm that the appliance as associated work has been installed as per manufacturer’s instructions and following any applicable building and installation codes. Signed:________________________________________ Print Name:____________________________________ Date:________________ Home Owner: RETAIN THIS INFORMATION FOR FUTURE REFERENCE 3 © 2021 United States Stove Company
ASSEMBLY INSTRUCTIONS FOR CUSTOMER SERVICE CALL: 800-750-2723 EXT 5050 BLOWER ASSEMBLY PEDESTAL BASE ASSEMBLY The blower assembly must be disconnected from 1. Assemble the pedestal base skirting. Attach two the source of electrical supply before attempting the corner pieces (A) to the center section (B) of skirting installation. The blower assembly is intended for use only and secure with four (4) truss head screws. with a stove that is marked to indicate such use. Do not route the supply cord near or across hot surfaces! Fix the assembly to the back of the stove with the four screws provided. A B 2. Attach the side skirting sections (C & D) to the corner pieces and secure with four (4) truss head screws. ASH PAN The ash pan is located below the firebox. C D 4 © 2021 United States Stove Company
ASSEMBLY INSTRUCTIONS 3. Slide the U-shaped skirting assembly around the FIREBRICK CONFIGURATION pedestal base and secure with two 1/4” long pan head Replace the Firebrick as shown in the illustration. sheet metal screws at the rear corners. INSTALLATION SAFETY NOTICE • IF THIS STOVE IS NOT PROPERLY INSTALLED, A HOUSE FIRE MAY RESULT. TO REDUCE THE RISK OF FIRE, FOLLOW THE INSTALLATION INSTRUCTIONS. • CONSULT YOUR MUNICIPAL BUILDING DEPARTMENT OR FIRE OFFICIALS ABOUT PERMITS, RESTRICTIONS AND INSTALLATIONS REQUIREMENTS IN YOUR AREA. • USE SMOKE DETECTORS IN THE ROOM WHERE YOUR STOVE IS INSTALLED. US Stove highly recommends your stove be installed by a qualified NFI (US) or WETT (Canada) technician. To find • KEEP FURNITURE AND DRAPES WELL AWAY FROM the nearest qualified installer, go to: THE STOVE. • NEVER USE GASOLINE, GASOLINE-TYPE LANTERN https://nficertified.org, FUEL, KEROSENE, CHARCOAL LIGHTER FLUID, OR https://www.wettinc.ca/ SIMILAR LIQUIDS TO START OR “FRESHEN UP” A FIRE IN THIS HEATER. KEEP ALL SUCH LIQUIDS POSITIONING THE STOVE WELL AWAY FROM THE HEATER WHILE IT IS IN USE. It is very important to position the wood stove as close • IN THE EVENT OF A CHIMNEY FIRE, PUSH THE AIR as possible to the chimney, and in an area that will favor CONTROL FULL CLOSED TO DEPRIVE THE FIRE OF the most efficient heat distribution possible throughout OXYGEN. CALL THE FIRE DEPARTMENT. the house. The stove must therefore be installed in the • DO NOT CONNECT TO ANY AIR DISTRIBUTION room where the most time is spent, and in the most DUCT OR SYSTEM. spacious room possible. Recall that wood stoves produce radiating heat, the heat we feel when we are close to a • A SOURCE OF FRESH AIR INTO THE ROOM OR SPACE wood stove. A wood stove also functions by convection, HEATED SHALL BE PROVIDED WHEN REQUIRED. that is through the displacement of hot air accelerated upwards and its replacement with cooler air. If necessary, the hot air distribution from the stove may be facilitated by the installation of a blower. The wood stove must not be hooked up to a hot air distribution system since an excessive accumulation of heat may occur. A wood stove must never be installed in a hallway or near a staircase, since it may block the way in case of fire or fail to respect required clearances. 5 © 2021 United States Stove Company
INSTALLATION FLOOR PROTECTOR This heater must have a non-combustible floor protector with an R-Value of at least 1.2 installed beneath it if the C A D floor is constructed of combustible material. If a floor pad is used, it should be UL listed or equal. The floor protector should be large enough to extend under the stove and beyond each side as indicated. If there is a horizontal run of flue pipe, there needs to be floor protection under it that extends two inches beyond either side of the pipe. REAR B SIDE SIDE E FRONT E Front 18” 458 mm A Backwall to Stove 17” 432 mm Back 8” 204 mm B Sidewall to Stove 26” 661 mm Sides 8” 204 mm C Sidewall to Flue 35” 889 mm D Backwall to Flue 19” 483 mm E Wall to corner (Angled Installation) 18” 458 mm CLEARANCES TO COMBUSTIBLES It is of utmost importance that the clearances to combustible materials be strictly adhered to during OUTSIDE COMBUSTION AIR installation of the stove. Your wood stove is approved to be installed with an • Do not place any combustible material within 4’ (1.2m) outside air intake (4FAK) which is necessary for a mobile of the front of the unit. home. This type of installation is also required in air tight houses and houses with negative pressure problems. You • Floor to ceiling height must be at least 7’ (2.13m) in all can purchase this option through your heater dealer. Make cases. sure to specify the part number mentioned in this booklet. • The clearance between the flue pipe and a wall are valid Installation instructions are supplied with the air intake kit. only for vertical walls and for vertical flue pipe. Outside combustion air may be required if • The chimney connector must not pass through an attic 1. Your stove does not draw steadily, smoke roll-out or roof space, closet or similar concealed space, a floor, occurs, wood burns poorly, or back-drafts occur or a ceiling. whether or not there is combustion present. • For Canadian installations, where passage through a 2. Existing fuel-fired equipment in the house, such as wall, or partition of combustible construction is desired, fireplaces or other heating appliances, smell, do the installation must conform to CAN/CSA-B365. not operate properly, suffer smoke roll-out when • A flue pipe crossing a combustible wall must have a opened, or back-drafts occur whether or not there is minimum clearance of 18” (458 mm). combustion present. • To reduce flue clearances from combustible materials, 3. Opening a window slightly on a calm (windless) day contact your local safety department. alleviates any of the above symptoms. 6 © 2021 United States Stove Company
INSTALLATION 4. The house is equipped with a well-sealed vapor barrier In addition to the previously detailed installation and tight fitting windows and/or has any powered requirements, the heater must be electrically grounded to devices that exhaust house air. the steel chassis of the mobile home with 8 GA copper 5. There is excessive condensation on windows in the wire using a serrated or star washer to penetrate paint or winter. protective coating to ensure grounding. 6. A ventilation system is installed in the house. CHIMNEY CONNECTOR (STOVE PIPE) Install crimped end 1/4” slope per foot towards stove. Flow Male Part Downwards Direction of Flue Gases 3 screws Slide the hose clamp over the aluminium flex pipe. Then slide the flex pipe over the air intake tube of the stove. Next tighten the hose clamp over the end of the aluminium flex hose. FOR USE IN MOBILE HOMES (U.S. ONLY) The chimney connector and chimney must have the • WARNING! DO NOT INSTALL IN SLEEPING ROOM. same diameter as the stove outlet (6”). If this is not the • CAUTION! THE STRUCTURAL INTEGRITY OF THE case, we recommend you contact your dealer to ensure MOBILE HOME FLOOR, WALL, AND CEILING/ROOF there will be no problem with the draft. The stovepipe MUST BE MAINTAINED. must be made of aluminized or cold roll steel and have • INSTALL IN ACCORDANCE WITH 24 CFR, PART a minimum thickness of 0.021” or 0.53 mm. It is strictly 3280 (HUD). forbidden to use galvanized steel. The smoke pipe should • USE A FACTORY BUILT CHIMNEY THAT COMPLIES be assembled to promote the male section (crimped WITH UL 103 STANDARDS; THEREFORE IT MUST end) of the pipe to be faced down. Attach each section to BE A TYPE HT (2100°F). another with three metal screws spaced an equal distance • USE A SPARK ARRESTER. apart. The pipe must be short and straight. All sections • THE STOVE MUST BE ATTACHED TO THE installed horizontally must slope at least 1/4 inch per foot, STRUCTURE OF THE MOBILE HOME. with the upper end of the section toward the chimney. Any installation with a horizontal run of chimney pipe must conform to NFPA 211. To ensure a good draft, the total SECURE APPLIANCE TO THE FLOOR length of the coupling pipe should never exceed 8’ to 10’ Use the designated holes to secure the unit to the floor. (2.4m to 3.04m). Except for cases of vertical installation, in a cathedral-roof style where the smoke exhaust system can be much longer and connected without problem to the chimney at the ceiling of the room. There should never be more than two 90 degrees elbows in the smoke exhaust system. The installation of a “barometric draft stabilizer” (fireplace register) on a smoke exhaust system is prohibited. Furthermore, the installation of a draft damper is not recommended. With a controlled combustion wood stove, the draft is regulated upon intake of the combustion air in the stove and not at the exhaust. 7 © 2021 United States Stove Company
INSTALLATION IMPORTANCE OF PROPER DRAFT 3. The installation of an interior chimney is always Draft is a force that moves air from the appliance up preferable to an exterior chimney. Indeed, the interior through the chimney. The amount of draft in your chimney chimney will, by definition, be hotter than an exterior depends on the length of the chimney, local geography, chimney, being heated up by the ambient air in the nearby obstructions and other factors. Too much draft house. Therefore the gas which circulates will cool may cause excessive temperatures in the appliance. An more slowly, thus reducing the build-up of creosote inadequate draft may cause back-puffing into the room and the risk of chimney fires. and “plugging” of the chimney. An inadequate draft will 4. The draft caused by the tendency for hot air to rise will cause the appliance to leak smoke into the room through be increased with an interior chimney. appliance and chimney connector joints. An uncontrollable 5. Using a fire screen at the extremity of the chimney burn or excessive temperature indicates an excessive requires regular inspection to ensure that it is not draft. obstructed thus blocking the draft, and it should be cleaned when used regularly. CHIMNEY FACTORY BUILT CHIMNEY Listed Attic Chimney Insulation Sheild Combustible Ceiling Joists Specified Clearance Chimney Ceiling Your wood stove may be hooked up with a 6” factory- Connector Support built or masonry chimney. If you are using a factory-built To Stove chimney, it must comply with UL 103 or CSA-B365 standard; therefore it must be a Type HT (2100°F). It must be installed Listed Cap according to the manufacturer’s specifications. Take into account the chimney’s location to ensure it is not too close Maintain 2” Storm Collar Clearance to neighbors or in a valley which may cause unhealthy or Flashing nuisance conditions. If you are using a masonry chimney, it must be built in compliance with the specifications Listed of the National Building Code. It must be lined with fire Chimney clay bricks, metal or clay tiles sealed together with fire cement. Round flues are the most efficient. The interior Ceiling diameter of the chimney flue must be identical to the stove Support smoke exhaust. A flue which is too small may cause draft * Refer to Clearance Chimney * problems, while a large flue favors rapid cooling of the gas, to Combustibles Connector and hence the build-up of creosote and the risk of chimney fires. Note that it is the chimney and not the stove which To Stove Combustible Wall creates the draft effect; your stove’s performance is directly Floor dependent on an adequate draft from your chimney. Do Protector not connect this unit to a chimney flue serving another appliance. The following recommendations may be useful for the installation of your chimney: 1. It must rise above the roof at least 3’ (0.9m) from the uppermost point of contact. When a metal prefabricated chimney is used, the 2. The chimney must exceed any part of the building or manufacturer’s installation instructions must be followed. other obstruction within a 10’ (3.04m) distance by a You must also purchase (from the same manufacturer) height of 2’ (0.6m). 8 © 2021 United States Stove Company
INSTALLATION and install the ceiling support package or wall pass- Wall Member: Using a minimum thickness 3.5” (89 mm) through and “T” section package, firestops (where needed), brick and a 5/8” (16 mm) minimum wall thickness clay insulation shield, roof flashing, chimney cap, etc. Maintain liner, construct a wall pass-through. The clay liner must proper clearance to the structure as recommended by the conform to ASTM C315 (Standard Specification for Clay manufacturer. The chimney must be the required height Fire Linings) or its equivalent. Keep a minimum of 12” above the roof or other obstructions for safety and proper (305 mm) of brick masonry between the clay liner and draft operation. wall combustibles. The clay liner shall run from the brick masonry outer surface to the inner surface of the chimney MASONRY CHIMNEY flue liner but not past the inner surface. Firmly grout or Ensure that a masonry chimney meets the minimum cement the clay liner in place to the chimney flue liner. standards of the National Fire Protection Association (NFPA) by having it inspected by a professional. Make sure there are no cracks, loose mortar or other signs of deterioration and blockage. Be sure to the chimney cleaned before the stove is installed and operated. When connecting the stove through a combustible wall to a masonry chimney, special methods are needed. Concrete Cap Fireclay Flue Liner With 1” Clearance Airspace with Firestop METHOD B - 9” (229 mm) Clearance to Combustible Wall Rafter Member: Using a 6” (153 mm) inside diameter, listed, Flashing Flashing factory-built Solid-Pak chimney section with insulation of 1” (26 mm) or more, build a wall pass-through with a Eave Combustible Wall minimum 9” (229 mm) air space between the outer wall 1” Clearance of the chimney length and wall combustibles. Use sheet Thimble 12” of Brick metal supports fastened securely to wall surfaces on all sides, to maintain the 9” (229 mm) air space. When fastening supports to chimney length, do not penetrate the chimney liner (the inside wall of the Solid-Pak chimney). Sheathing The inner end of the Solid-Pak chimney section shall be flush with the inside of the masonry chimney flue, and sealed with a non-water soluble refractory cement. Use this cement to also seal to the brick masonry penetration. To Stove Floor Protector Airtight Cleanout Door COMBUSTIBLE WALL CHIMNEY CONNECTOR PASS-THROUGHS METHOD A - 12” (305 mm) Clearance to Combustible 9 © 2021 United States Stove Company
INSTALLATION METHOD C - 6” (153 mm) Clearance to Combustible Use this as a pass-through for a minimum 24-gauge single Wall Member: Starting with a minimum 24 gage (.024” wall steel chimney connector. Keep solid-pak section [.61 mm]) 6” (153 mm) metal chimney connector, and a concentric with and spaced 1” (26 mm) off the chimney minimum 24 gage ventilated wall thimble which has two connector by way of sheet metal support plates at both air channels of 1” (26 mm) each, construct a wall pass- ends of chimney section. Cover opening with and support through. There shall be a minimum 6” (153 mm) separation chimney section on both sides with 24 gage minimum area containing fiberglass insulation, from the outer sheet metal supports. See that the supports are fastened surface of the wall thimble to wall combustibles. Support securely to wall surfaces on all sides. Make sure fasteners the wall thimble, and cover its opening with a 24-gage used to secure chimney flue line do not penetrate the inner minimum sheet metal support. Maintain the 6” (153 mm) liner. space. There should also be a support sized to fit and hold the metal chimney connector. See that the supports are fastened securely to wall surfaces on all sides. Make sure fasteners used to secure the metal chimney connector do not penetrate chimney flue liner. NOTES: • Connectors to a masonry chimney, excepting method B, shall extend in one continuous section through the wall pass-through system and the chimney wall, to but not METHOD D - 2” (51 mm) Clearance to Combustible Wall past the inner flue liner face. Member: Start with a solid-pak listed factory built chimney • A chimney connector shall not pass through an attic or section at least 12” (304 mm) long, with insulation of 1” roof space, closet or similar concealed space, or a floor, (25.4 mm) or more, and an inside diameter of 8” (2 inches or ceiling. [51 mm] larger than the 6” [153 mm] chimney connector). 10 © 2021 United States Stove Company
OPERATION INSTRUCTIONS NEVER OPERATE THIS PRODUCT WHILE UNATTENDED OPERATING SAFETY PRECAUTIONS lower emissions generally result when burning air dried seasoned hardwoods, as compared to softwoods or too • NEVER OVERFIRE THIS APPLIANCE BY BUILDING green or freshly cut hardwoods. The following resources EXCESSIVELY HOT FIRES AS A HOUSE/BUILDING can assist in learning the burn characteristics of various FIRE MAY RESULT. YOU ARE OVERFIRING THE species of wood: http://firewoodresource.com/firewood- APPLIANCE IF IT BEGINS TO GLOW OR TURN RED. btu-ratings/; or https://forestry.usu.edu/forest-products/ • NEVER BUILD EXCESSIVELY LARGE FIRES IN THIS wood-heating The operation of this wood heater in a TYPE OF APPLIANCE AS DAMAGE TO THE FIREBOX manner inconsistent with the owner’s manual will void your OR SMOKE LEAKAGE MAY RESULT. warranty and is also against federal regulations. Waste • DO NOT BUILD FIRE TOO CLOSE TO THE GLASS. and other flammable materials should not be burned in • HOT WHILE IN OPERATION. KEEP CHILDREN, your stove. DO NOT BURN: CLOTHING, AND FURNITURE AWAY. CONTACT 1. Garbage; MAY CAUSE SKIN BURNS. DO NOT TOUCH THE 2. Lawn clippings or yard waste; APPLIANCE UNTIL IT HAS COOLED. • PROVIDE ADEQUATE AIR FOR COMBUSTION TO 3. Materials containing rubber, including tires; THE ROOM WHERE THE APPLIANCE IS INSTALLED. 4. Materials containing plastic; • INSPECT CHIMNEY LINER EVERY 60 DAYS. 5. Waste petroleum products, paints or paint thinners, or REPLACE LINER IMMEDIATELY IF IT IS RUSTING OR asphalt products; LEAKING SMOKE INTO THE ROOM. 6. Materials containing asbestos; • ATTEMPTS TO ACHIEVE HEAT OUTPUT RATES THAT EXCEED HEATER DESIGN SPECIFICATIONS 7. Construction or demolition debris; CAN RESULT IN PERMANENT DAMAGE TO THE 8. Railroad ties or pressure-treated wood; HEATER. 9. Manure or animal remains; 10. Saltwater driftwood or other previously salt water- WARNING: EXPLOSION HAZARD saturated materials; • NEVER USE CHEMICALS, GASOLINE, GASOLINE- TYPE LANTERN FUEL, KEROSENE, CHARCOAL 11. Unseasoned wood; or LIGHTER FLUID, OR SIMILAR FLAMMABLE LIQUIDS 12. Paper products, cardboard, plywood, or particleboard. TO START OR “FRESHEN UP” A FIRE IN THE The prohibition against burning these materials does APPLIANCE. not prohibit the use of fire starters made from paper, • KEEP ALL FLAMMABLE LIQUIDS, ESPECIALLY cardboard, sawdust, wax, and similar substances to GASOLINE, OUT OF THE VICINITY OF THE start a fire in an affected wood heater. APPLIANCE - WHETHER IN USE OR IN STORAGE. Burning these materials may result in the release of toxic fumes or render the heater ineffective and cause smoke. CAUTIONS: HOUSE FIRE HAZARDS Deadwood lying on the forest floor should be considered • DO NOT STORE WOOD ON FLOOR PROTECTOR, wet and requires full seasoning time. Standing deadwood UNDERNEATH STOVEPIPE(S) OR ANYWHERE can usually be considered to be about 2/3 seasoned. WITHIN CLEARANCES TO COMBUSTIBLE Smaller pieces of wood will dry faster. All logs exceeding SURFACES SPECIFIED FOR THIS APPLIANCE. 6” in diameter should be split. The wood should not be stored directly on the ground. Air should circulate through • NEVER OPERATE WITH SECONDARY TUBES, the logs. A 24” to 48” air space should be left between FIBERBOARD, OR INSULATION REMOVED. each row of logs, which should be placed in the sunniest location possible. The upper layer of wood should be WOOD STOVE UTILIZATION protected from the element but not the sides. A good Your heating appliance was designed to burn well indicator of if the wood is ready to burn is to check the seasoned natural wood only; no other materials should piece ends. If cracks are radiating in all directions from the be burned. Any type of well seasoned natural wood center then the wood should be dry enough to burn. If your may be used in your stove, but specific varieties have wood sizzles in the fire, even though the surface is dry, it better energy yields than others. Higher efficiencies and may not be fully cured and should be seasoned longer. It 11 © 2021 United States Stove Company
OPERATION INSTRUCTIONS is EXTREMELY IMPORTANT that you use DRY WOOD only regulations to alter this setting or otherwise operate this in your wood stove. The wood should have dried for 9 to wood heater in a manner inconsistent with operating 15 months, such that the humidity content (in weight) instructions in this manual. is reduced below 20% of the weight of the log. It is very important to keep in mind that even if the wood has been EFFICIENCIES cut for one, two, or even more years, it is not necessarily Efficiencies can be based on either the lower heating value dry, if it has been stored in poor conditions. Under extreme (LHV) or the higher heating value (HHV) of the fuel. The conditions, it may rot instead of drying. This point cannot lower heating value is when water leaves the combustion be overstressed; the vast majority of the problems related process as a vapor, in the case of woodstoves the to the operation of a wood stove is caused by the fact moisture in the wood being burned leaves the stove as a that the wood used was too damp or had dried in poor vapor. The higher heating value is when water leaves the conditions. These problems can be: combustion process completely condensed. In the case • ignition problems of woodstoves this would assume the exhaust gases are room temperature when leaving the system, and therefore • creosote build-up causing chimney fires calculations using this heating value consider the heat • low energy yield going up the chimney as lost energy. Therefore, efficiency • blackened windows calculated using the lower heating value of wood will be higher than efficiency calculated using the higher heating • incomplete log combustion value. The best way to achieve optimum efficiencies is to Do not burn manufactured logs made of learn the burn characteristic of you appliance and burn wax impregnated sawdust or logs with any well-seasoned wood. Higher burn rates are not always the chemical additives. Manufactured logs best heating burn rates; after a good fire is established a made of 100% compressed sawdust can be lower burn rate may be a better option for efficient heating. burned, but be careful burning too much of A lower burn rate slows the flow of usable heat out of the these logs at the same time. Start with one manufactured home through the chimney, and it also consumes less log and see how the stove reacts. You can increase wood. the number of logs burned at a time but make sure the temperature never rises higher than 475 °F (246 °C) on a NOTICE INITIAL BURNS TO CURE PAINT magnetic thermometer for installation on single wall stove BECAUSE OF HIGH OPERATING TEMPERATURES, THIS pipes. The thermometer should be placed about 18” (457 APPLIANCE IS COATED WITH A SPECIAL HIGH TEMP mm) above the stove. Higher temperatures can lead to PAINT WHICH REQUIRES A SERIES OF LOW TO MEDIUM overheat and damage your stove. BURNS TO FULLY CURE FOR DURABILITY AND A LIFETIME OF SERVICE. TESTING YOUR WOOD Proper curing of the high-temp paint requires a series of • When the stove is thoroughly warmed, place one piece three initial burns. The appliance should be allowed to of split wood (about five inches in diameter) parallel to cool off between each burn. The first two burns should be the door on the bed of red embers. small fires and low temperatures (250°F) for a duration of • Keep the air control fully open and close the door. If 20 minutes each. The third fire should be at a temperature the wood ignites within 90 seconds from the time it of approximately 500°F for 20 minutes. Provide adequate was placed in the stove, your wood is correctly dried. If cross ventilation to clear any smoke or odor caused by ignition takes longer, your wood is damp. initial firings. • If your wood hisses and water or vapor escapes at Notice: Use solid wood fuel only! Do not burn garbage, or the ends of the piece, your wood is soaked or freshly flammable fluids. Do not use coal. This appliance is not cut (green). Do not use this wood in your stove. Large designed to accommodate the air flow (draft) required to amounts of creosote could be deposited in your chimney, properly burn coal or coal products. Do not elevate the creating potential conditions for a chimney fire. fire using grates or irons. Build the fire directly on the firebrick. TAMPER WARNING This wood heater has a manufacturer-set minimum low FUELING INSTRUCTIONS burn rate that must not be altered. It is against federal This wood stove has been certified by the US EPA to 12 © 2021 United States Stove Company
OPERATION INSTRUCTIONS meet strict 2020 guidelines. To ensure this unit produces setting. For a medium burn, once the high burn fuel load is the optimal minimum emissions it is critical that only burned down to an established coal bed, load the unit with well-seasoned cordwood is burned (see the “Fuel 31 to 32 lbs of cordwood and keep the door slightly open Recommendations” section of this manual). Burning for 2 minutes. After two minutes close the door. Keep the unseasoned wet wood only hurts your stoves efficiency secondary airslide fully open for 10 minutes then close and leads to accelerated creosote buildup in your chimney. completely and set the primary airslide halfway closed. At Be considerate of the environment and only burn dry wood. the 15 minute point of loading your fuel, the primary air slide should be set at the medium setting which is about CAUTION: 1/2 inch open from the fully closed position. DO NOT LEAVE APPLIANCE UNATTENDED THE WITH DOOR OPEN. For a cold start-up, place 4 to 5 pieces of newspaper into the firebox. On top of the newspaper, lay 5 lbs of kindling in a random placement to ensure airflow through the kindling. On top of the kindling, place approximately 6.5 lbs of small pieces of cordwood. NOTE: Use smaller pieces of wood during start-up and a high burn rate to increase the stove temperature. 31 to 32 lbs 6.5 lbs For a low burn setting once the high burn (or medium) fuel load is burned down to an established coal bed, load the unit with 31 to 32 lbs of cordwood and leave the door open for two minutes. After two minutes close the door. Keep the secondary airslide fully open for 10 minutes then close completely and set the primary airslide halfway closed. At the 15 minute point of loading your fuel, the primary air slide should be set at the low setting which is pulling the airslide completely out toward you. NOTE: Do not close the air too quickly. Closing the air too quickly will cause the unit to smoke. Push both air control slides to the fully open position. Light the newspaper and close the door. Once the kindling HEARTH has burned down to a starter coal bed, load the unit with approximately 26 to 27 lbs of fuel for the first high burn CONTROL OPEN OPEN CONTROL load. LEVER LEVER A B (Primary Air) (High Burn) CLOSED CLOSED HEARTH CONTROL OPEN OPEN CONTROL LEVER LEVER A B 26 to 27 lbs (Primary Air) (High Burn) After the first high burn load and the stove is well warmed CLOSED CLOSED up, adjust the unit as needed for a medium or low burn 13 © 2021 United States Stove Company
OPERATION INSTRUCTIONS VISIBLE SMOKE HEARTH The amount of visible smoke being produced can be an effective method of determining how efficiently the CONTROL OPEN OPEN CONTROL combustion process is taking place in the given settings. LEVER LEVER Visible smoke consists of unburned fuel and moisture A B leaving your stove. Learn to adjust the air settings of your (Primary Air) (High Burn) specific unit to produce the smallest amount of visible smoke. Wood that has not been seasoned properly and CLOSED CLOSED has a high wood moisture content will produce excess visible smoke and burn poorly. HEARTH AIR TUBES The air tubes assembled in this unit are designed to CONTROL OPEN OPEN CONTROL provide an accurate mix of secondary air to ensure the LEVER LEVER highest efficiency. Any damage or deterioration of these A B tubes may reduce the efficiency of combustion. The air (Primary Air) (High Burn) tubes are held in position by screws or snap pins. Locate these to either side of the tube and remove it to allow the CLOSED CLOSED tube to be removed and replaced. WARNINGS: BLOWER OPERATION • NEVER OVERFIRE YOUR STOVE. IF ANY PART OF The variable-speed blower circulates air warmed by the THE STOVE STARTS TO GLOW RED, OVER FIRING IS firebox into the living area to distribute the heat more HAPPENING. READJUST THE AIR INTAKE CONTROL evenly. The blower control knob is located on the side of AT A LOWER SETTING. the blower housing. Turn the knob clockwise to turn the • THE INSTALLATION OF A LOG CRADLE OR GRATES blower on. The speed is controlled by turning the knob IS NOT RECOMMENDED IN YOUR WOOD STOVE. clockwise for slower speeds and counter-clockwise BUILD FIRE DIRECTLY ON FIREBRICK. for faster speeds. To turn the blower off, turn the speed • NEVER PUT WOOD ABOVE THE FIREBRICK LINING control knob fully counter-clockwise. It is recommended OF THE FIREBOX. to turn the blower off when the unit is not in operation. The blower should be removed at the beginning of every “burn” • ATTEMPTS TO ACHIEVE HEAT OUTPUT RATES season and air-blown clean, removing any dust or build-up. THAT EXCEED HEATER DESIGN SPECIFICATIONS CAN RESULT IN PERMANENT DAMAGE TO THE HEATER. 14 © 2021 United States Stove Company
CHIMNEY MAINTENANCE NEVER OPERATE THIS PRODUCT WHILE UNATTENDED CAUTION: • Always check for creosote deposit once every two months and have your chimney cleaned at least once DO NOT OVERFIRE APPLIANCE. YOU ARE OVERFIRING a year. IF ANY PART OF THE APPLIANCE GLOWS RED. CLOSE THE DOOR AND SHUT DAMPER IMMEDIATELY TO • If a chimney or creosote fire occurs, close all dampers REDUCE THE AIR SUPPLY AND SLOW DOWN THE FIRE. immediately. Wait for the fire to go out and the heater to cool, then inspect the chimney for damage. If no damage results, perform a chimney cleaning to ensure CAUTION: no more creosote deposits is remaining in the chimney. SLOW BURNING FIRES FOR EXTENDED USE OR BURNING GREEN WOOD MAY CAUSE EXCESSIVE CAUTION: CREOSOTE BUILD-UP. IGNITION OF CREOSOTE A CHIMNEY FIRE MAY CAUSE IGNITION OF WALL OR OVERFIRING COULD CAUSE A CHIMNEY FIRE. STUDS OR RAFTERS WHICH WERE ASSUMED TO CHIMNEY FIRES BURN EXTREMELY HOT AND MAY BE A SAFE DISTANCE AWAY FROM THE CHIMNEY. IGNITE SURROUNDING COMBUSTIBLE MATERIALS. IF A CHIMNEY FIRE OCCURS, HAVE YOUR CHIMNEY IN CASE OF A CHIMNEY FIRE, CALL THE FIRE INSPECTED BY A QUALIFIED EXPERT BEFORE USING DEPARTMENT IMMEDIATELY! AGAIN. CREOSOTE FORMATION & NEED FOR ASH REMOVAL & DISPOSAL REMOVAL Whenever ashes get 3 to 4 inches deep in your firebox or When wood is burned slowly, it produces tar and other ash pan, and when the fire has burned down and cooled, organic vapors, which combine with expelled moisture remove excess ashes. Leave an ash bed approximately to form creosote. The creosote vapors condense in the 1 inch deep on the firebox bottom to help maintain a hot relatively cool chimney flue of a slow-burning fire. As a charcoal bed. Ashes should be placed in a metal container result, creosote residue accumulates on the flue lining. with a tight-fitting lid. The closed container of ashes should When ignited this creosote makes an extremely high be placed on a non-combustible floor or the ground, away temper fire. The chimney connector and chimney should from all combustible materials, pending final disposal. be inspected at least once every two months during the The ashes should be retained in the closed container until heating season to determine if a creosote build-up has all cinders have thoroughly cooled. occurred. If creosote has accumulated (3 mm or more), it should be removed to reduce the risk of a chimney fire. We strongly recommend that you install a magnetic CAUTIONS: thermometer on your smoke exhaust pipe, approximately • ASHES COULD CONTAIN HOT EMBERS EVEN AFTER 18” above the stove. This thermometer will indicate the TWO DAYS WITHOUT OPERATING THE STOVE. temperature of your gas exhaust fumes within the smoke • THE ASH PAN CAN BECOME VERY HOT. WEAR exhaust system. The ideal temperature for these gases GLOVES TO PREVENT INJURY. is somewhere between 275°F and 500°F. Below these • NEVER BURN THE STOVE WITH THE ASH TRAP temperatures, the build-up of creosote is promoted. Above OPEN. THIS WOULD RESULT IN OVER FIRING THE 500°F, heat is wasted since a too large quantity is lost into STOVE. DAMAGE TO THE STOVE AND EVEN HOUSE the atmosphere. FIRE MAY RESULT. TO PREVENT CREOSOTE BUILD UP • Always burn dry wood. This allows clean burns and SMOKE & CO MONITORS higher chimney temperatures, therefore less creosote Burning wood naturally produces smoke and carbon deposit. monoxide(CO) emissions. CO is a poisonous gas when exposed to elevated concentrations for extended periods. • Leave the air control fully open for about 5 min. every While the modern combustion systems in heaters time you reload the stove to bring it back to proper drastically reduce the amount of CO emitted out the operating temperatures. The secondary combustion can chimney, exposure to the gases in closed or confined only take place if the firebox is hot enough. areas can be dangerous. Make sure your stove gaskets 15 © 2021 United States Stove Company
CHIMNEY MAINTENANCE and chimney joints are in good working order and sealing wood stoves are sold. The glass should be washed only properly to ensure unintended exposure. It is recommended when cold. that you use both smoke and CO monitors in areas having the potential to generate CO. GASKET CARE GLASS CARE WARNING: • Inspect and clean the glass regularly to detect any NEVER OPERATE THE STOVE WITHOUT A GASKET OR cracks. If you spot one, turn the stove off immediately. WITH A BROKEN ONE. DAMAGE TO THE STOVE OR Do not abuse the glass door by striking or slamming EVEN HOUSE FIRE MAY RESULT. shut. Do not use the stove if the glass is broken. • If the glass on your stove breaks, replace only with the This unit’s door uses a 3/4” diameter rope gasket. It is glass supplied from your heater dealer. Never substitute recommended that you change the door gasket (which other materials for the glass. makes your stove door air tight) once a year, in order to • To replace the glass, remove the screws retaining the ensure good control over the combustion, maximum glass moldings inside the door. Remove the moldings efficiency and security. To change the door gasket, simply and replace the damaged piece with a new one. Perform remove the damaged one. Carefully clean the available the procedure backward after replacing it. When gasket groove, apply a high temperature silicone sold for replacing the glass, you should change the glass gasket this purpose, and install the new gasket. You may light to make sure you keep it sealed. up your stove again approximately 24 hours after having • Never wash the glass with a product that may scratch. completed this operation. Use a specialized product, available in the stores where HOW TO ORDER REPAIR PARTS For Parts Assistance Call: 800-750-2723 Ext 5051 or Email: parts@usstove.com The information in this owner’s manual is specific to your unit. When ordering replacement parts the information in this manual will help to ensure the correct items are ordered. Before contacting customer service write down the model number and the serial number of this unit. That information can be found on the certification label attached to the back of the unit. Other information that may be needed would be the part number and part description of the item(s) in question. Part numbers and descriptions can be found in the “Repair Parts” section of this manual. Once this information has been gathered you can contact customer service by phone 1-800-750-2723 Ext 5051 or Email parts@usstove.com. Model Information Model Number Serial Number 16 © 2021 United States Stove Company
REPAIR PARTS 2 1 4 5 6 3 12 8 7 9 11 10 Key Part # Description Qty 9 40597 Skirt Corner 2 1 892268 Heat Shield (Left) 1 10 26546 Front Skirt 1 2 892269 Heat Shield (Rear) 1 11 26553 Right Side Skirt 1 3 892267 Heat Shield (Right) 1 12 69911 Pedestal 1 4 892278 Top Trim 1 To order parts: 5 892279 Hearth Trim 1 6 69912 Ash Drawer 1 Call 1-800-750-2723 Ext 5051 or 7 26548 Ash Drawer Support 1 Email to: parts@usstove.com 8 26541 Left Side Skirt 1 IN ORDER TO MAINTAIN WARRANTY, COMPONENTS MUST BE REPLACED USING ORIGINAL MANUFACTURERS PARTS PURCHASED THROUGH YOUR DEALER OR DIRECTLY FROM THE APPLIANCE MANUFACTURER. USE OF THIRD PARTY COMPONENTS WILL VOID THE WARRANTY. 17 © 2021 United States Stove Company
REPAIR PARTS Key Part # Description Qty 1 88194 C-Cast Bottom 2 13 2 892280 Notched Firebrick 2 3 891414 Half Firebrick 3 8 12 4 89066 Firebrick (4-1/2 X 9) 20 7 11 5 892281 1.5” Firebrick 2 10 6 40595 Half Brick Ash Plug 1 9 5 7 86698 Tube(1), Secondary Air Tube (4mm) 1 8 86699 Tube(2,3), Secondary Air Tube (3mm) 2 9 86700 Tube(4), Secondary Air Tube (2.5mm) 1 4 10 86701 Tube(5), Secondary Air Tube (2.0mm) 1 11 86702 Tube(6), Secondary Air (No Holes) 1 6 12 88192 Ceramic Fiber Board Top 2 2 13 88193 Kao Wool 1 3 To order parts: Call 1-800-750-2723 Ext 5051 or Email to: parts@usstove.com 1 Key Part # Description Qty 7 1 891135 Spring Handle 1 2 892266 Handle Assembly 1 6 5 3 40596 Ponderosa Cast Door 1 4 3 4 88082 Rope Gasket 3/4” 3.5 ft 8 5 892270 Glass, Chamber Door 1 1 6 26533 Lg-Cut, Glass Retainer 1 2 7 26534 Glass Retainer 4 8 26536 Glass Retainer Lg 1 9 83922 Pin w/Cotter, Hinge 2 To order parts: 9 Call 1-800-750-2723 Ext 5051 or Email to: parts@usstove.com IN ORDER TO MAINTAIN WARRANTY, COMPONENTS MUST BE REPLACED USING ORIGINAL MANUFACTURERS PARTS PURCHASED THROUGH YOUR DEALER OR DIRECTLY FROM THE APPLIANCE MANUFACTURER. USE OF THIRD PARTY COMPONENTS WILL VOID THE WARRANTY. 18 © 2021 United States Stove Company
WIRING DIAGRAM DANGER: SHOCK HAZARD. DISCONNECT POWER SOURCE BEFORE INSTALLATION AND WHENEVER SERVICING BLOWER ASSEMBLY. CAUTION: MOVING PARTS CAN CAUSE INJURY. DO NOT OPERATE WITH COVER REMOVED. White Black Black Black Black Black Blower Rheostat Blower Motor Blower Specs: Attach Ground 110, 60 Hz AC, To Back Of Green White 0.55 amp Blower Housing Power Supply NOTICE: DO NOT ALLOW POWER CORD TO TOUCH HOT SURFACES! KEEP POWER CORD AWAY FROM STOVE OR PIPE SURFACES. NOTICE: ANY REPLACEMENT WIRING MUST HAVE EQUIVALENT INSULATION AND TEMPERATURE RATING (105°C). 19 © 2021 United States Stove Company
SERVICE RECORD It is recommended that your heating system is serviced regularly and that the appropriate Service Interval Record is completed. SERVICE PROVIDER Before completing the appropriate Service Record below, please ensure you have carried out the service as described in the manufacturer’s instructions. Always use the manufacturer's specified spare part when replacement is necessary. Service 01 Date:________________________ Service 02 Date:________________________ Engineer Name:______________________________________ Engineer Name:______________________________________ License No.:_________________________________________ License No.:_________________________________________ Company:____________________________________________ Company:____________________________________________ Telephone No.:_______________________________________ Telephone No.:_______________________________________ Stove Inspected: Chimney Swept: Stove Inspected: Chimney Swept: Items Replaced:______________________________________ Items Replaced:______________________________________ Service 03 Date:________________________ Service 04 Date:________________________ Engineer Name:______________________________________ Engineer Name:______________________________________ License No.:_________________________________________ License No.:_________________________________________ Company:____________________________________________ Company:____________________________________________ Telephone No.:_______________________________________ Telephone No.:_______________________________________ Stove Inspected: Chimney Swept: Stove Inspected: Chimney Swept: Items Replaced:______________________________________ Items Replaced:______________________________________ Service 05 Date:________________________ Service 06 Date:________________________ Engineer Name:______________________________________ Engineer Name:______________________________________ License No.:_________________________________________ License No.:_________________________________________ Company:____________________________________________ Company:____________________________________________ Telephone No.:_______________________________________ Telephone No.:_______________________________________ Stove Inspected: Chimney Swept: Stove Inspected: Chimney Swept: Items Replaced:______________________________________ Items Replaced:______________________________________ Service 07 Date:________________________ Service 08 Date:________________________ Engineer Name:______________________________________ Engineer Name:______________________________________ License No.:_________________________________________ License No.:_________________________________________ Company:____________________________________________ Company:____________________________________________ Telephone No.:_______________________________________ Telephone No.:_______________________________________ Stove Inspected: Chimney Swept: Stove Inspected: Chimney Swept: Items Replaced:______________________________________ Items Replaced:______________________________________ 20 © 2021 United States Stove Company
ENREGISTREMENT DE SERVICE Il est recommandé que votre système de chauffage est desservi régulièrement et que le Service Interval enregistrement approprié est terminée. FOURNISSEUR DE SERVICES Avant de terminer l’enregistrement de service approprié ci-dessous, s’il vous plaît vous assurer que vous avez effectué le service tel que décrit dans le les instructions du fabricant. Toujours utiliser pièce de rechange indiquée par le fabricant lors de remplacement est nécessaire. Service de 01 Date: _______________________ Service de 02 Date: _______________________ Nom de l’ingénieur: __________________________________ Nom de l’ingénieur: __________________________________ N° de licence.:_______________________________________ N° de licence.:_______________________________________ Compagnie: _________________________________________ Compagnie: _________________________________________ N° de téléphone: ____________________________________ N° de téléphone: ____________________________________ Poêle Inspecté: Cheminée balayée: Poêle Inspecté: Cheminée balayée: Articles Remplacé: __________________________________ Articles Remplacé: __________________________________ Service de 03 Date: _______________________ Service de 04 Date: _______________________ Nom de l’ingénieur: __________________________________ Nom de l’ingénieur: __________________________________ N° de licence.:_______________________________________ N° de licence.:_______________________________________ Compagnie: _________________________________________ Compagnie: _________________________________________ N° de téléphone: ____________________________________ N° de téléphone: ____________________________________ Poêle Inspecté: Cheminée balayée: Poêle Inspecté: Cheminée balayée: Articles Remplacé: __________________________________ Articles Remplacé: __________________________________ Service de 05 Date: _______________________ Service de 06 Date: _______________________ Nom de l’ingénieur: __________________________________ Nom de l’ingénieur: __________________________________ N° de licence.:_______________________________________ N° de licence.:_______________________________________ Compagnie: _________________________________________ Compagnie: _________________________________________ N° de téléphone: ____________________________________ N° de téléphone: ____________________________________ Poêle Inspecté: Cheminée balayée: Poêle Inspecté: Cheminée balayée: Articles Remplacé: __________________________________ Articles Remplacé: __________________________________ Service de 07 Date: _______________________ Service de 08 Date: _______________________ Nom de l’ingénieur: __________________________________ Nom de l’ingénieur: __________________________________ N° de licence.:_______________________________________ N° de licence.:_______________________________________ Compagnie: _________________________________________ Compagnie: _________________________________________ N° de téléphone: ____________________________________ N° de téléphone: ____________________________________ Poêle Inspecté: Cheminée balayée: Poêle Inspecté: Cheminée balayée: Articles Remplacé: __________________________________ Articles Remplacé: __________________________________ 20 © 2021 United States Stove Company
DIAGRAMME DE FIL DANGER: RISQUE D’ÉLECTROCUTION. DÉBRANCHER L’ALIMENTATION ÉLECTRIQUE AVANT L’INSTALLATION ET LORS DE L’ENTRETIEN DE L’AS-SEMBLAGE DU VENTILATEUR REFOULANT. ATTENTION: PIÈCES MOBILES POUVANT CAUSER DES BLESSURES. NE PAS FAIRE FONCTIONNER SI LE COU-VERCLE EST RETIRÉ. Blanc Noir Noir Noir Noir Noir Rhéostat du ventilateur Moteur du ventilateur Lier la mise à la terre Détails techniques: au dos du 110v, 60 Hz CA, Vert Blanc 0,05AMP compartiment du ventilateur Alimentation Electrique AVIS: NE PAS LAISSER LE FIL ÉLECTRIQUE ENTRER EN CONTACT AVEC UNE SURFACE CHAUDE! GARDER LE FIL ÉLECTRIQUE À 12PO / 30CM AU MOINS DE LA SURFACE DU POÊLE OU DES CONDUITS. AVIS: TOUT CÂBLAGE DE REMPLACE-MENT DOIT AVOIR UNE ISOLATION ET DES CARACTÉRISTIQUES THERMIQUES SIMILAIRES A L’ORIGINAL (105°C). 19 © 2021 United States Stove Company
PIÈCES DE RECHANGE Clé Partie # La Description Qté 1 88194 C-Cast Bas 2 2 892280 Brique de feu entaillée 2 13 3 891414 Demi brique réfractaire 3 4 89066 Brique réfractaire (4-1 / 2 x 9) 20 8 12 5 892281 1,5 po brique réfractaire 2 7 11 6 40595 Bouchon de cendre demi-brique 1 10 7 86698 Tube d'air secondaire (1) (4 mm) 1 9 5 8 86699 Tube d'air secondaire (2,3) (3 mm) 2 9 86700 Tube d'air secondaire (4) (2,5 mm) 1 10 86701 Tube d'air secondaire (5) (2,0 mm) 1 11 86702 Tube d'air secondaire (6) (sans trous) 1 4 12 88192 Plateau en fibre de céramique 2 13 88193 Laine Kao 1 6 Pour commander des pièces: 2 3 Appelez le 1-800-750-2723 Ext 5051 ou Envoyez un courriel à: parts@usstove.com 1 Clé Partie # La Description Qté 7 1 891135 Poignée à ressort 1 2 892266 Assemblage de la poignée 1 6 5 3 40596 Porte coulée 1 4 4 88082 Joint de corde 3/4 po 3,5 pi 3 8 5 892270 Verre, porte de la chambre 1 Retenue en verre de grande 1 6 26533 1 2 taille 7 26534 Verre de retenue 4 8 26536 Grand verre de retenue 1 Broche avec goupille, 9 83922 2 charnière 9 Pour commander des pièces: Appelez le 1-800-750-2723 Ext 5051 ou Envoyez un courriel à: parts@usstove.com AFIN DE MAINTENIR LA GARANTIE, LES COMPOSANTS DOIVENT ÊTRE REMPLACÉS PAR DES PIÈCES D’ORIGINE ACHETÉES CHEZ VOTRE REVENDEUR OU DIRECTEMENT AUPRÈS DU FABRICANT DE L’APPAREIL. L’UTILISATION DE COMPOSANTS TIERS ANNULERA LA GARANTIE. 18 © 2021 United States Stove Company
PIÈCES DE RECHANGE 2 1 4 5 6 3 12 8 7 9 11 10 Clé Partie # La Description Qté 9 40597 Coin de jupe 2 1 892268 Bouclier thermique (gauche) 1 10 26546 Jupe avant 1 2 892269 Bouclier thermique (arrière) 1 11 26553 Jupe côté droit 1 3 892267 Bouclier thermique (droite) 1 12 69911 Piédestal 1 4 892278 Garniture supérieure 1 5 892279 Garniture de foyer 1 Pour commander des pièces: 6 69912 Tiroir à cendres 1 Appelez le 1-800-750-2723 Ext 5051 ou 7 26548 Support de tiroir à cendres 1 Envoyez un courriel à: parts@usstove.com 8 26541 Jupe côté gauche 1 AFIN DE MAINTENIR LA GARANTIE, LES COMPOSANTS DOIVENT ÊTRE REMPLACÉS PAR DES PIÈCES D’ORIGINE ACHETÉES CHEZ VOTRE REVENDEUR OU DIRECTEMENT AUPRÈS DU FABRICANT DE L’APPAREIL. L’UTILISATION DE COMPOSANTS TIERS ANNULERA LA GARANTIE. 17 © 2021 United States Stove Company
You can also read