Table of Contents Safety Instructions ....................................................................................... 2 Introduction ................................................................................................. 3 Control Panel ............................................................................................... 3 Remote Controller ....................................................................................... 3 Quick Start .................................................................................................. 4 Turn ON and Turn OFF ...................................................................... 4 Setting Up the Temperature ............................................................... 4 Operation Menu .......................................................................................... 5 Air Furnaces ......................................................................................... 5 Boilers ................................................................................................... 5 The Software ............................................................................................... 6 Main Menu .............................................................................................. 6 Temperature ........................................................................................ 6 Temperature Menu .............................................................................. 7 Fan ........................................................................................................ 7 Week Timer .......................................................................................... 7 Settings Menu ......................................................................................... 9 Date-Time............................................................................................ 9 Screen-Sounds .................................................................................... 10 Language ............................................................................................ 10 Service ................................................................................................. 10 Troubleshooting ......................................................................................... 11 1 Smartpel Controller Owner’s Manual
Safety Instructions Please read the owner manual carefully before operating your pellet stove/boiler. Caution! Schock Hazard! Risk of electrical schock which may cause serious injuries or death. Please disconnect the mains before servicing this equipment. Caution! Hot Surfaces! The boiler/stove assembly and/or the temperature sensors may be extremely hot! Caution! Moving Parts! Watch your hands while servicing the moving parts such as auger and/or rotary fuel feeding assembly which may cause serious injuries. Caution! This device is intended to be professionally installed. Incorrect installation and/or operating parameters may cause dangerous conditions. 2 Smartpel Controller Owner’s Manual
Introduction Thank you for buying the World’s most advanced pellet stove controller. Smartpell will made the winter more comfortable with the all benefits of reneweable energy, thanks to its advanced software technology. Control Panel 1. LCD Display: Smartpel has a 128 by 64 pixels graphical display 2. Command Dial: Instead of complicated buttons, swtiches and ligts Smartpel controller has an easy to use push&rotate command dial just like your car stereo 3. Remote Controller Sensor Remote Controller Smartpel controller has an Infrared remote controller for basic settings. Increase Temperature Decrease Temperature Increase Fan Speed Decrease Fan Speed Power ON/OFF (Remote controller is not available for all models) 3 Smartpel Controller Owner’s Manual
Quick Start Turn ON and Turn OFF Push and hold the command dial until the countdown has been completed. If you release the button in less than 5 seconds, power state will not change. Setting Up the Temperature Push command dial to enter the Main Menu Push the command dial again to enter Temperature Setup Clockwise rotation of the command dial will increase the temperature and Counter clockwise rotation will do vice versa. Push command dial to return. 4 Smartpel Controller Owner’s Manual
Operation Menu Air Furnaces Time Power State Preset Temp. Actual Current FAN Temperature Status Status Boilers Time Power State Exhaust Preset Temp. Temp. Actual Current Output Temperature Status Power 5 Smartpel Controller Owner’s Manual
The Software Smartpel controller software has two menu groups for Users and a menu group for service professionals. Push the command dial in order to launch the Main Menu. Rotate the command dial clockwise or counter clockwise to navigate in the Menu Group. Main Menu Return Settings Temperature Week Timer Fan Temperature Adjusts the desired temperature. Air Furnaces Boilers Boiler+Air Furnaces Launches the Adjusts room Adjusts boiler temperature temperature temperature Temperature Menu 6 Smartpel Controller Owner’s Manual
Temperature Menu Return Boiler Temp Room Temp Fan Adjusts the fan speed in five steps or automatic. Ventilation fans are not available in boilers. Automatic Manual (5 speed) Week Timer The week timer allows you to set three programs for each day of the week to turn on or turn off your boiler. To set up the week timer, first select the desired day of the week. 7 Smartpel Controller Owner’s Manual
Day: Sun Push command Day: Sun dial Highlighted Highlighted Rotate the Push command command dial to proceed. dial to select Than highlight the Active switch: Active: (OFF) Selected day’s schedules are disabled. Push to toggle (ON) Selected day’s schedules are enabled. Than select and adjust the turn on and turn off times. Turn-ON Turn-OFF time settings time settings After all settings are completed rotate the command dial to highlight Return and push the command dial to exit. 8 Smartpel Controller Owner’s Manual
Settings Menu Return Service Date-Time Language Screen-Sounds Date-Time Adjusts the system date and time. Day of the week will be calculated automatically. About the backup battery: Instead of cadmium and/or mercury contained batteries, Smartpel controller has an environment friendly, lead and mercury free super capacitor. Backup super capacitor can operate the onboard clock/calendar at least 3 months without recharging. 9 Smartpel Controller Owner’s Manual
Screen-Sounds Brightness: Adjusts the backlight brightness of the LCD display. Dim Screen: Adjusts a timer to dim the screen backlights. It can be disabled by adjusting to “Never”. Illumination: Enables/disables the command dial illumination. Volume: Adjusts the notification sound leves. Language Selects the user interface language. Some languages may not be available for all versions. Service Launches the Service Menu. Please note that the Service Menu is only for maintenance professionals and it is password protected. 10 Smartpel Controller Owner’s Manual
Troubleshooting Symtoms Possible Reason Workaround Dark Screen Power switch is off Turn on power swtich Fuse is blown up Replace fuse Mains power failure Check for the mains power Controller is not Actual temperature is Adjust the starting the flame higher than the temperature setpoint setpoint Room thermostat is Switch on the room OFF thermostat Error Message: Low airflow Check the air Overtemp. Detected ventilation Pump malfunction Check the pump Temp. Sensor Call service malfunction Controller Call service malfunction Error Message: Out of fuel Add pellets to hopper Burnout detected Low quality pellets Use high quality pellets Exhaust temp. Sensor Call service malfunction Exhaust fan Call service malfunction Error Message: Back burning to fuel Check the fuel Backburning detected hopper hopper. Drain the pellets if necessary. Error Message: Insufficient chimney Check chimney Insufficient flue draught system draught Clot in chimney pipes Check chimney system Negative air Bad/poor chimney deppression to system or too windy chimney environment 11 Smartpel Controller Owner’s Manual
Error Message: Low quality pellets Use high quality Ignition Failed pellets Too low ambient Try to start fire temperature manually Ignition heater Call service malfunction Exhaust temp. Sensor Call service malfunction Error Message: Sensor and/or Call service Sensor failure: malfunction Error Message: Controller Call service BOOT Failure malfunction (Or blank screen with blinking command dial illumination in green colour) 12 Smartpel Controller Owner’s Manual
(This page is intentionally left blank.) 13 Smartpel Controller Owner’s Manual