Generator description

The T25 is available in 2 versions- a standard and a low-chloride version.
The difference between standard and low-chloride version is the quantity of remaining chloride in the
NEUTHOX®. (Standard 3800 mg/L low Chloride 1700 mg/L). In applications with recirculation of the water
(cooling towers, ice water, tunnel pasteurizations applications) we recommend using the low chloride
version.

The T25 standard is available in five capacities 40, 80, 120, 250 and 400 litres per hour. The T25 low
chloride is available in three capacities 50, 100 and 250 litres per hour.
The size of generator you require is dependent on the amount of water you wish to treat and the initial
conditions of the water. On the next page, you will find a dosing guide to assist you in calculating your
requirements. The capacity is based on 20 operation hours per day. This allows for a safety margin to
account for unexpected increase in the water’s biological load and also provides enough time for the
generator to perform automatic self-maintenance routines.

The pH and thereby the relation between NEUTHOX® and CATHOX® can be adjusted in the PLC
(please see the manual) The production split can be adjusted between 100 % NEUTHOX® pH 8, 0, 50%
NEUTHOX® pH 3,4 and 50 % CATHOX® pH 11, 3. (See specifications in table on page 4)
In order to commission the generator the technician needs to know the hardness of the local water supply
in order to set the built in water softener to the correct regenerating cycle. (Hardness kit included in
delivery)

A 3 Micron filter is built in the generator to remove particles that could affect the optimal performance of
the generator. If however your water supply has a high level of sediment we recommend installing an
external filter between the potable water supply and the generator. High levels of Iron and Manganese can
adversely affect the performance of the generator cell. The built in softening system will remove low levels
of these contaminants. If the level is above 0,5 mg/L for iron and 0.1 mg/L for manganese we would
recommend that a separate removal system is installed. Our partner company will be happy to advise you
on this point with an additional filter. If you are using well water and it is contaminated with oxidized Iron
or Manganese (the water often takes on a red/ brown colour) a separate removal system is always
necessary.
The generator requires a 3 phase 400 volt 50/60 Hz power supply located within 3 meters of the generator
plus a potable water supply, having pressure between three and seven bar with a shut off valve
terminating in a fitting within 2 meters of the generator. Please see page 3 for full specification and
requirements of the generator. There should also be a suitable wastewater point or connection within 3
meters of the generator.
T25 series: Standard Low chloride - The T25 series of Disinfectant Generators are developed to be used in many different water applications
Dosing Levels and Methods

The amount of NEUTHOX® which should be added to a water system is dependent on the application and
the biological load within the water. The higher the biological load the greater the concentration.
Experience has shown that for the majority of applications dosing levels in the range of 1:1000(0,5 PPM ) to
1:500 ( 1,0 PPM) are sufficient.
In some cases a water sample analyzes can be very useful to determine the needed dosing level
In these cases, please send a sample of 1 litre to our address through your partner.

         Dosing Guide T 25 Standard

         Generator size    Generator Capacity                 M3 water to be treated

                           Litre/h Litre/day       0,5 PPM    1,00 PPM     2,00 PPM     3,00 PPM
         T 25 – 40            40       800            800        400          200          133
         T 25 - 80            80      1600           1600        800          400          266
         T 25 - 120          120      2400           2400       1200          600          400
         T 25 - 250          250      5000           5000       2500         1250          833
         T 25 - 400          400      8000           8000       4000         2000         1.333

        Dosing Guide T 25 Low Chloride

          Generator size    Generator Capacity                M3 water to be treated

                            Litre   Litre/day     0,5 PPM     1,00 PPM     2,00 PPM    3,00 PPM
                            /h
          T 25 – 50         50      1000            1000        500          250          167
          T 25 – 100        100     2000            2000        1000         500          333
          T 25 - 250        250     5000            5000        2500         1250         833
T25 series: Standard Low chloride - The T25 series of Disinfectant Generators are developed to be used in many different water applications
Technical Specifications - Standard

Generator type                                       T 25- 40           T25-80         T 25-120       T 25-250   T 25 -400
NEUTHOX® production 100%                L/h              40                80              120            250       400
Operation per day                       h                                                   20
Free chlorine
(100% NEUTHOX®)
                                        mg/L                                               500
NEUTHOX® production 50 %                L/h                20                40            60            125        250
CATHOX® production                      L/h                20                40            60            125        250
Approximate salt                        kg/day
consumption*
                                                           6,4              12,8          19,2            40        64
Electrical connections                  V/Hz                       EU 3x 400/50-60,US 1x 120/ 60, CA 1x 220 /50
                              2
Cable Length 5x 1,5 mm                  m                                               3
Power consumption                       W                  850           1350        1800           3500        5400
Enclosure                               IP                                             54
Approval                                CE mark                                        Yes
Water supply with 15L/min               bar                                           > 2½
Water connection                        BSP                                                ½”
Drain connection                        BSP                                                ½”
Drain hose- minimum                     mm
diameter
                                                                                           ½”
Drain hose- maximum length              m                                                   5
                                        Iron
T25 series: Standard Low chloride - The T25 series of Disinfectant Generators are developed to be used in many different water applications
Technical Specifications - Low Chloride

             Generator type                                           T 25-50          T25-100      T25-250
             NETHOX® production 100%                 L/h                   50               100       250
             Operation per day                       h                                      20
             Free chlorine
                                                     mg/L                                   500
             (100% NEUTHOX®)
             NEUTHOX® production 50 %                L/h                   25               50        125
             CATHOX® production                      L/h                   25               50        125
             Approximate salt                        kg/day
                                                                           4,2              8,4       21
             consumption*
                                                     V/Hz               EU 3x 400/50-60,US 1x 120/ 60,
             Electrical connections
                                                                                CA 1x 220 /50
                                           2
             Cable Length 5x 1,5 mm                  m                                3
             Power consumption                       W                   1300       2050        4850
             Enclosure                               IP                              54
             Approval                                CE mark                         Yes
             Water supply with 15L/min               bar                            > 2½
             Water connection                        BSP                                    ½”
             Drain connection                        BSP                                    ½”
             Drain hose- minimum                     mm
             diameter                                                                       ½”
             Drain hose- maximum length              m                                     5
                                                     Iron
T25 series: Standard Low chloride - The T25 series of Disinfectant Generators are developed to be used in many different water applications
T25 series: Standard Low chloride - The T25 series of Disinfectant Generators are developed to be used in many different water applications
Space requirements for the T25 generator

                                                                                     1 meter
Tank overflow            Power max. 3 meters              Drain hose max. 3 meters

                                                3 meter

      DCW T25 – Electrical Components

     Transformer for PLC
     etc..
     Transmitter for
     conductivity sensor
     220 V for service PC
     Transformer for
     process
     (switch mode for big
     generators – core
     transformer for
     small)

     Sensor - amperage
T25 – Mechanical Components

                                                                                          Electrolyses cell
                                                                              CATHOX® valve
                                                         3/2 valve for descaling
                              Figure 2-1
3/2 valve for hydrogen

Conductivity sensor

Venting outlet for acid

Hydrogen venting

Brine pump

Mixing chamber

Pressure valve (acid)

Manometer

Pressure switch
process

Flow meter

Water filter

Main control valve

Pressure reduction

Check valve

Acid (Limescale remover)

Manometer

Acid pump
(behind container)

                                           Pressure switch – inlet

                                                           Water softener
Company description

Danish Clean Water A/S (DCW) is located on Danfoss Industrial Park in Southern Denmark.
It was founded to exploit the technology of on-site production of environ mentally safe disinfection systems
for bacterial control.

DCW has access to the full range of Danfoss facilities at its Headquarters in Southern Denmark. These
include a state of the art fully accredited laboratory plus a manufacturing facility world renowned for its
quality of engineering. All DCW machines are manufactured by Danfoss Industry Services to the highest
standards of engineering excellence.

 Danish Clean Water A/S
 c/o Danfoss A/S
 Nordborgvej 81
 E 17 B206
 6430 Nordborg
 Denmark

 Phone +45 70 29 09 00
 Fax   +45 70 29 09 01

 © 2008. The written and pictorial material in this document is the property of Danish Clean Water A/S and its partners and may not be
 copied, disseminated or reproduced in any form without the written permission of Danish Clean Water A/S.
You can also read