Q10 EURO NCAP 2020 HARDWARE & FE MODEL UPDATES - Jerry Wang (Ph. D) & Fuchun Zhu - Humanetics

Page created by Karl Palmer
 
CONTINUE READING
Q10 EURO NCAP 2020 HARDWARE & FE MODEL UPDATES - Jerry Wang (Ph. D) & Fuchun Zhu - Humanetics
Q10 EURO NCAP 2020 HARDWARE
& FE MODEL UPDATES
Jerry Wang (Ph. D) & Fuchun Zhu
Q10 EURO NCAP 2020 HARDWARE & FE MODEL UPDATES - Jerry Wang (Ph. D) & Fuchun Zhu - Humanetics
2

Contents
• Part One – Brief of Q10 Euro NCAP 2020 upgrade kit
• Part Two – Q10 Euro NCAP 2020 FE model updates

©2019 Confidential & Proprietary
Q10 EURO NCAP 2020 HARDWARE & FE MODEL UPDATES - Jerry Wang (Ph. D) & Fuchun Zhu - Humanetics
3

Overview time line of Q10 developments
2009            2010               2011      2012          2013      2014         2015           2016         2017          2018       2019     2020

EU funded project                                                                     Euro NCAP
EPOCh                                                                                 initiative
Requirements                              Feedback          Abdomen                   Requirements Q10 2020
 Design and Prototyping                   Design updates    pressure sensor                                         Validation
                                                                                       FE supported Trade off study
  Validation and Evaluation               Production        integration                                             Evaluation
                                                                                        Design and Prototyping
                                                                                                                             Q10 2020
                                                                                                                             Final design
                                                                                                                             Production

                                                                          Hip liner

                                                                                ASIS Load Cell
                                                                                                     UNECE Regulation 129            Future harmonization
                                                                                                                                         with Euro NCAP?

©2019 Confidential & Proprietary
Q10 EURO NCAP 2020 HARDWARE & FE MODEL UPDATES - Jerry Wang (Ph. D) & Fuchun Zhu - Humanetics
4

Q10 Changes Driven By Euro NCAP Child WG
• Seating Posture
        ◦ Match UMTRI Child Anthropometry – head and neck position
• Proper Belt Engagement and Kinematics
        ◦ Shoulder belt – shoulder pad
        ◦ Lap belt – thigh flesh
• Mass distribution improvement
        ◦ Migrate mass from pelvis to thorax
• Other usage issues experienced in testing
        ◦ Foot interference with front seat
        ◦ Scapula interference with shoulder rubber and ribcage

©2019 Confidential & Proprietary
Q10 EURO NCAP 2020 HARDWARE & FE MODEL UPDATES - Jerry Wang (Ph. D) & Fuchun Zhu - Humanetics
5

Euro NCAP 2020 Q10 Contents
• Euro NCAP Child WG Decision: Sept 2018
• Head and neck position at neck base
        ◦ Reposition the dummy according to
          UMTRI child seating posture
        ◦ Forward shift the neck by 20 mm
        ◦ Rotate the head rearward by 5.3 degrees
• Shoulder liner to cover shoulder joints
• Scapula eliminated
• Mass shift pelvis to thorax 1.4 kg
• Upper legs with solid flesh
• Lower legs with shorter feet

©2019 Confidential & Proprietary
Q10 EURO NCAP 2020 HARDWARE & FE MODEL UPDATES - Jerry Wang (Ph. D) & Fuchun Zhu - Humanetics
6

Q10 Euro NCAP 2020 Kit Status
• Euro NCAP Q10 Upgrade Kit is finalized and available for the users
• Euro NCAP New Test Protocol takes effective on Jan 1, 2020
• Euro NCAP Dynamic Tests – total 30 channels, plus 4 optional
        ◦   Head acceleration x,y,z
        ◦   Upper neck force Fx, Fy, Fz, moment Mx, My, Mz
        ◦   Shoulder force Fx, Fy, Fz
        ◦   T1 acceleration y (side only)
        ◦   Chest (T4) acceleration x,y,z,
        ◦   Chest displacement and rotation
        ◦   Lumbar spine force Fx, Fy, Fz and moment Mx, My, Mz
        ◦   Pelvis acceleration x,y,z
        ◦   Pubis force Fy (side only)
        ◦   Iliac wing (L&R) force Fx, My (optional)

©2019 Confidential & Proprietary
Q10 EURO NCAP 2020 HARDWARE & FE MODEL UPDATES - Jerry Wang (Ph. D) & Fuchun Zhu - Humanetics
Part Two: Q10 Euro NCAP 2020 FE Models
Development

                    MK-FO-00036C, Rev A
Q10 EURO NCAP 2020 HARDWARE & FE MODEL UPDATES - Jerry Wang (Ph. D) & Fuchun Zhu - Humanetics
8

  Q10 Dummy Model Development History/Status
       2015                             2016                        2017                             2018                             2019

                                                                                                March 2018: Based on evaluation results,
                                                                                                Euro NCAP CWG decided for limited update
                                                                                                by restoring some original Q10 parts

                                                                                                                           Hardware Status
                                                                                                                           • Validation/Testing
                                                                                         New Q10                           • Third Party Evaluation
                                                                                         Euro NCAP 2020
                     Reports to Euro NCAP, Advisory Board and Conferences                Design. FE model                  FE model release 3rdQ 2019
                                                                                         available for evaluation
                             Q10 2020      V1.0 Concept Model V1.0 Full Prototype 2017                              V1.1                   V1.2

Design/FE analysis loop done in all stages of development-concept to launch!
  ©2019 Confidential & Proprietary
Q10 EURO NCAP 2020 HARDWARE & FE MODEL UPDATES - Jerry Wang (Ph. D) & Fuchun Zhu - Humanetics
9

Q10 Euro NCAP 2020 Dummy Model v1.1
                        • FEA V1.1 Model developed to follow Euro NCAP
                          2020 specifications; and released late 2018;
                        • V1.1 dynamic performance to mimic hardware
                          closely;
                        • Updated parts of known materials, known
                          geometry change
                                   ◦   Solid/rigid metal parts spine and pelvis
                                   ◦   Solid/rigid scapula
                                   ◦   Solid/elastic shoulder pad*
                                   ◦   Solid/elastic lower leg
                                   ◦   Solid/elastic thigh flesh current production*
                        • Extra option (feature): *stiffness parameter
                          variables in FEA model (Thigh, Shoulder liner)

©2019 Confidential & Proprietary
Q10 EURO NCAP 2020 HARDWARE & FE MODEL UPDATES - Jerry Wang (Ph. D) & Fuchun Zhu - Humanetics
10

Q10 Euro NCAP 2020 Dummy Model v1.1
 • V1.1 model represents the state of art design and
   functionality of the hardware kit/materials
 • Thigh flesh/Shoulder liner parameters for stiffness
   variation
 • Additional parameters on Jacket, neck, hip shields to
   help users run belt slip on shoulder and chin to
   clavicle contact studies

©2019 Confidential & Proprietary
11

Q10 Euro NCAP 2020 SK Dummy Model v1.1
• V1.1 SK model released in April 2019
• The SK (side kit) arm with shoulder assembly is fitted on
  the Euro NCAP 2020 v1.1 model
• Modified scapula

©2019 Confidential & Proprietary
New Validation Tests for v1.2 Model
     Planned Release Date: 9/2019

          • Neck mini sled tests
          • Lumbar spine mini sled tests
          • Abdomen foam drop tests
          • APTS pendulum impact tests

          MK-FO-00036C, Rev A
13

Neck Mini Sled Tests
• Focus on validating combined bending/torsion mode;
• Total of 40 tests were executed at multiple speeds, with/without neck cable;
• Considering possible hardware variations - two necks.
                            Neck1 (EJ8877)           Neck 2 (EJ6567)
 Impact
 velocity                With         Without   With cable     Without
                         cable         cable                    cable
             Test 1        √            √           √             √
  2 m/s
             Test 2        √            √           √             √
             Test 1        √            √           √             √
  3 m/s
             Test 2        √            √           √             √
             Test 1        √            √           √             √
  4 m/s
             Test 2        √            √           √             √
             Test 1        √            √           √             √
  5 m/s
             Test 2        √            √           √             √
             Test 1        √            √           √             √
  6 m/s
             Test 2        √            √           √             √

   ©2019 Confidential & Proprietary
14

Neck Mini Sled Tests
• Neck kinematics to replicate loading level seen in a vehicle test.
                                                                a
• Initial Position reference for FEA established via Laser scanning.
• Validation based on 3 independent sets of signals.
a. Ballast Acceleration & Angular velocity outputs.             b

b. Upper Neck Loadcell Forces & Moments.
                                                                c
c. Lower Neck Loadcell Forces & Moments.

 ©2019 Confidential & Proprietary
15

Neck Mini Sled Tests
Upper Neck Loads: 6 m/s (with Cable)

                                                                                   Test
                                                                                   V1.1
                                                                                   V1.2

• Focused on Upper Neck Loadcell signals - important for EuroNCAP injury rating.
 ©2019 Confidential & Proprietary
16

Neck Mini Sled Tests
Lower Neck Loads: 6 m/s (with Cable)

                                       Test
                                       V1.1
                                       V1.2

 ©2019 Confidential & Proprietary
17

Neck Mini Sled Tests
Ballast Kinematics angular velocity: 6 m/s (with Cable)

                                                          Test
                                                          V1.1
                                                          V1.2

 ©2019 Confidential & Proprietary
18

Lumbar Spine Mini Sled Tests
• Focus on validating combined bending/torsion mode;
• Total of 32 tests were executed at multiple speeds, with/without lumbar cable;
• Considering possible hardware variations - two lumbar spines.

                            Lumbar 1 (EJ2521)       Lumbar 2 (EJ5778)
Impact
velocity                  With        Without   With cable   Without cable
                          cable        cable
             Test 1         √             √         √             √
 3 m/s
             Test 2         √             √         √             √
             Test 1         √             √         √             √
 4 m/s
             Test 2         √             √         √             √
             Test 1         √             √         √             √
 5 m/s
             Test 2         √             √         √             √
             Test 1         √             √         √             √
 6 m/s
             Test 2         √             √         √             √

  ©2019 Confidential & Proprietary
19

Lumbar Spine Mini Sled Tests
• Lumbar kinematics to replicate loading level seen in a vehicle test
                                                                a
• Initial Position reference for FEA established via Laser scanning.
• Validation based on 2 independent sets of signals.
a. Ballast Acceleration & Angular velocity outputs.
b. Lumbar Spine Loadcell Forces & Moments.                    b

  ©2019 Confidential & Proprietary
20

Lumbar Spine Mini Sled Tests
Ballast Kinematics angular velocity: 6 m/s (with Cable)

                                                          Test
                                                          V1.2

 ©2019 Confidential & Proprietary
21

Lumbar Spine Mini Sled Tests
Loadcell loads: 6 m/s (with Cable)

                                     Test
                                     V1.2

 ©2019 Confidential & Proprietary
22

Abdomen Foam Drop Tests
Motivation for additional testing:
1.        Abdomen stiffness is an important parameter which affects the kinematics of upper torso flexion, chin to
          chest contact & Neck Fz;
2.        CAE customers reported that the abdomen material is very stiff and leads to over-prediction of the Upper
          Neck Fz forces;
3.        Humanetics proposed an interim solution by validating the abdomen insert using the TU-B sled setup;
4.        The next step is to validate the Abdomen using a drop test setup.

                Upper Neck Force-Z
              Stiffer Abdomen
              Tuned (softer) Abdomen

                                                                                       Abdomen Insert
     ©2019 Confidential & Proprietary
23

Abdomen Foam Drop Tests
• Component level tests with isolated the abdomen;
• Total of 27 tests were executed at multiple speeds;
• Hardware variability-three test subjects.

    Impact                           Abdomen 1   Abdomen 2     Abdomen 3
    velocity                          (EJ4177)    (DY 7779)   (Q10-10001)

                   Test 1                √           √            √
   1.55 m/s        Test 2                √           √            √
                   Test 3                √           √            √
                   Test 1                √           √            √
   2.51 m/s        Test 2                √           √            √
                   Test 3                √           √            √
                   Test 1                √           √            √
   3.38 m/s        Test 2                √           √            √
                   Test 3                √           √            √
                                                                            Drop Tower Setup
  ©2019 Confidential & Proprietary
24

Abdomen Foam Drop Tests (without skin)

          Drop speed:
          1.55m/s                   Test
          2.51 m/s                  V1.1
          3.38 m/s                  V1.2

 ©2019 Confidential & Proprietary
25

Abdomen Foam Drop Tests (with skin)

          Drop speed:
          1.55m/s                     Test
          2.51 m/s                    V1.1
          3.38 m/s                    V1.2

 ©2019 Confidential & Proprietary
26

APTS sensor FE model development
• APTS (Abdomen Pressure Twin Sensor) are used for Abdomen injury
  assessment. Injury criteria are under ECE regulation R129. The sensor
  is used in the Q family dummies and THOR family dummies;
• Earlier beta version sensor model released in December 2016;
• Further work planned for the sensor validation based on component
  testing

 ©2019 Confidential & Proprietary
27

APTS sensor FE model development
• Sensor validation based on Component Tests – multiple speeds

                                          APTS 50 mm
                                          test @ 0.74 m/s
                                          test @ 1.13 m/s
                                          FE in Red

  • Peak pressure (bar) values/timing profile of the sensor
    match with the validation domain of the ECE-R129
    legislation requirements.

 ©2019 Confidential & Proprietary
28

Full Dummy Validations: Thorax Frontal Impact
• FE data validation based on
   o   Thorax repeat tests at multiple speeds.
   o   Use high-speed videos for kinematic correlation.
   o   Total of 40 dummy channels used for FE/test correlation.
   o   Positioning reference-Tilt sensors and laser pendulum alignment

                                                                         Tilt sensor outputs
   ©2019 Confidential & Proprietary
29

Full Dummy Validations: Thorax Lateral Impact
• FE data validation based on
   o   Thorax repeat tests at multiple speeds.
   o   Use high-speed videos for kinematic correlation.
   o   Total of 40 dummy channels used for FE/test correlation.
   o   Positioning reference-Tilt sensors and laser pendulum alignment

                                                                         Tilt sensor outputs
   ©2019 Confidential & Proprietary
30

Full Dummy Validations: Pelvis Lateral Impact
• FE data validation based on
   o   Pelvis repeat tests at multiple speeds
   o   Use high-speed videos for kinematic correlation
   o   Total of 40 dummy channels used for FE/test correlation
   o   Positioning reference-Tilt sensors and laser alignment of pendulum

                                                                            Tilt sensor outputs
   ©2019 Confidential & Proprietary
31

In Summary
A major update release of Q10 Euro NCAP 2020 dummy FE model
v1.2 is scheduled for September 2019.

      Additional component validations – Abdomen/Neck/Lumbar Spine/APTS
      Full body validations – Thorax/Pelvis/Abdomen/Femur
      Address customer feedbacks
      Meet Euro NCAP 2020 specifications

 ©2019 Confidential & Proprietary
Thank you for your attention

Acknowledges: Q10 Euro NCAP 2020 FE model
       development team members

             Renuka Jagadish
             Vinit Manjarekar
         Apoorva Lakshminarayana

                  MK-FO-00036C, Rev A