Z·20·00275 Zoning Case Number l. Descripti_on of request by Zoning Section Number(s): Section 134·843 (7): The Applicant Is proposing a new 9,416 square foot two story residence on Via Bellarla that would have a building height plane setback of 37 feet In lieu of the required minimum setback ranging from 51.2 to 69.5 feet. Ill. APPLICATIONS CONTAINING VARIANCES If the application contains requests for variances, please respond to the questions below, and complete Exhibit B (Findings for authorizing a variance as stated in the Town's Zoning Code at Section 134-201). a. Applicant should provide a brief description of the special conditions which when subjected to a literal enforcement of the provisions of the zoning ordinance will result in unnecessary and undue HARDSHIP. This explanation should be a summary of information provided in Exhibit B. The hardship, which runs with the land, Is that In order for the proposed house to be In line with the other houses on Via Bellarla (the majority of which are landmarked) the front setback requirement should be decreased. b. Applicant should address how granting of a variance for these special conditions will not be contrary to the public's interest. The granting of the variance will not be contrary to the public's Interest as the proposed residence is In line with the houses on Via Bellarla and the design matches the streetscape. IV. SITE HISTORY Please provide a detailed history in chronological order of all zoning-related requests processed on or after January l, 1970 applicable to this property. None. Respectfully submitted, Applicant's Signature Prop�rty Owner's Signature ( or his/her duly authorized attorney) Mauro Ziska, Attorney for Dan Swanson Maura Ziska, Attorney for Dan Swanson Typed name & telephone # 561-802-8960 Typed name & telephone # 561-802-8960
Z-20-00275
Z-20-00275
A-02 Z-20-00275 1 1/4" = 1’−0"
A-03 Z-20-00275 1 1/4" = 1’−0"
B-020-2020 Z-20-00275 A-04
B-020-2020 Z-20-00275 A-05
A-06 Z-20-00275 1 1/4" = 1’−0"
Z-20-00275
B-020-2020 Z-20-00275 A-08
RELOCATED FICUS TREE 4' HT. ALUMINUM PICKET UNDERPLANTED WITH A SHADE POOL FENCE GARDEN OF ALOCACIA, MONSTERA, EX. 5' CHAIN LINK FENCE ON PHILODENDRON, TI PLANTS, DWARF ADJACENT PROPERTY DATE PALM AND NATIVE FERN EXISTING FICUS TREES Xref F:\20\20-003\ARCOM submittal\20-003-TL.dwg TO REMAIN 132 NORTH SWINTON AVENUE FICUS HEDGE TO REMAIN DELRAY BEACH, FL 33444 T (561) 276-5050 www.agtland.com 5' UTILITY FPL VAULT EASEMENT PODOCARPUS HEDGE AND GOLD MOUND BORDERED ARECA PALMS AND TI BY FICUS GREEN ISLAND PLANTS BORDERED BY FICUS GREEN ISLAND EX. CONC PAD AND GENERATOR ON ADJACENT PROPERTY 4' HT. ALUMINUM PICKET POOL FENCE ON OUTSIDE OF DRAINAGE CURB CURVED COCONUTS WITH ACCENT PALM SUCH POOL EMPIRE ZOYSIA BOUGAINVILLEA VINE AS BLUE LATANIA GRASS LIGUSTRUM TREES 24" X 24" CAST STONE PAVERS IN IVORY PODOCARPUS 4' HT. ALUMINUM PICKET PALMS ON ADJACENT PROPERTY PRINGLES POOL FENCE ON OUTSIDE EX. TREE CANOPY ON OF DRAINAGE CURB ADJACENT PROPERTY CONFEDERATE JASMINE VINE ON COLUMNS CURVED COCONUT PALM WITH BOUGAINVILLEA VINE AND MONSTERA ACCENTS 3-RELOCATED PODOCARPUS HEDGE AND FOXTAIL PALMS GOLD MOUND BORDERED BY FICUS GREEN ISLAND LIGUSTRUM TREES BOUGAINVILLEA VINES PODOCAPRUS HEDGE WITH GARDENIA CURVED COCONUT PALMS STANDARDS WITH BOUGAINVILLEA UNDERPLANTED WITH ATTACHED TO TRUNK PENTAS PALMS ON ADJACENT PROPERTY PAVER DRIVEWAY GREEN BUTTONWOOD LAYERED PLANTING OF 8' HT. TREES PODOCARPUS HEDGE AND YAUPON HOLLY EX. 4' CHAIN LINK FENCE JAPANESE BLUEBERRY ON ADJACENT PROPERTY TREES- 14' HT. BOUGAINVILLEA VINES AND RELOCATED ADONIDIAS TRIPLE ALEXANDER PALMS TO MATCH PALMS FRAMING EX. TREE CANOPY ON ENTRY ADJACENT PROPERTY PROPERTY LINE SCALE: 1"=10'-0" Saved: 7/6/2020 4:46 PM EXISTING FICUS TREE 8' HT. PODOCARPUS HEDGE ZAMIA TO REMAIN WITH GOLD DUST CROTONS BOUGAINVILLEA VINE ON FLORIDA AND ASIATIC JASMINE TRIPLE ALEXANDER PALMS TRELLIS ABOVE WINDOWS FRAMING FRONT ENTRY ASIATIC JASMINE FICUS GREEN ISLAND VIBURNUM HEDGE WITH GROUNDCOVER IN FRONT OF LOW YELLOW IXORA WINDOWS PINWHEEL JASMINE PROJECT AND TI PLANTS WITH ZAMIA FLORIDANA AND VARIEGATED ASIATIC JASMINE. 171 VIA BELLARIA \\WSERVER\Shared Folders\Shares\Work\Project Files\Addison-171 Via Bellaria\Agtland\LP-9.dwg SYLVESTER DATE PALMS FRAMING DRIVEWAY PALM BEACH, FLORIDA YELLOW CROWN OF THORNS WITH FICUS GREEN ISLAND BORDER ARCOM NUMBER 17' X 16' FPL EASEMENT B-020-2020 TITLE 6' HT. PODOCARPUS HEDGE SYLVESTER DATE PALMS WITH IXORA NORA GRANT WITH CROWN OF THORNS AND YAUPON HOLLY BORDER AND FICUS GREEN ISLAND LANDSCAPE PLAN PROJ. NO. FILE NAME DRAWN DATE REV. SHEET LP-1 OF 1
N88°52'14"W 118.50 48 HOURS BEFORE DIGGING CALL 1-800-432-4770 SUNSHINE STATE ONE CALL OF FLORIDA, INC. Contractor is responsible for obtaining location of existing utilities prior to commencement of construction activities. G CE N01°07'46"E Intracoastal Waterway 33.10' Via Serena Clarendon Ave. WEST PALM BEACH, FL 33401 2475 MERCER AVE., SUITE 305 Gruber Consulting Site office@gruberengineers.com Atlantic Ocean Engineers, Inc. PHONE: 561.312.2041 FAX: 561.537.7229 Via Bellaria Via Del Lago N Proposed S88°52'14"E South Ocean Blvd. Via Palma Pool 16.50' Algoma Rd. Kings Rd. Woodbridge Rd. 04/17/2020 2020-0037 1/8"=1'-0" Project Information KM CG Location Map N.T.S. Checked By Project No. Issue Date Drawn By STORMWATER RETENTION CALCULATIONS Scale A. SITE INFORMATION Total Property Area = 21,729 sq.ft. Proposed Drainage Area (excludes roadway) = 20,041 sq.ft. Drainage Area Impervious Surface (proposed residence, driveway, walkway, pool, deck, pergola) = 9,024 sq.ft. Palm Beach, Florida Drainage Area Pervious Surface = 11,017 sq.ft. 165.00' Legend B. ESTIMATED STORMWATER RETENTION VOLUME Addison Developement Group Inc. The retention volume is estimated using the Rational Method (Q=CiA) where: C = 1.0 (impervious surface) C = 0.2 (pervious surface) i = 2 in/hr Conceptual Site Grading & Drainage Plan For: Proposed Two Story Residence N01°07'46"E Impervious Surface Runoff Volume: 1.0 x 2 in/hr x 9,024 sq.ft. x 1 ft./12 in. = 1,504 cu.ft. Min. F.F. Elev. = 7.33 NAVD Pervious Runoff Volume: 0.2 x 2 in/hr x 11,017 sq.ft. x 1 ft./12 in. = 368 cu.ft. 119.40' Total Volume to be Retained = 1,872 cu.ft. C. PROPOSED EXFILTRATION TRENCH SIZING L = Total Length of Trench Provided = 70 ft W = Trench Width = 12 ft K = Hydraulic Conductivity = 0.00005 cfs/sq.ft./ft. of head S01°07'46"W H2 = Depth to Water Table = 3.75 ft DU = Un-Saturated Trench Depth = 3.00 ft DS = Saturated Trench Depth = 0.00 ft V = Volume Treated = 2,014 cu.ft. Proposed Driveway Proposed 171 Via Bellaria Notes: Garage 1) Exfiltration trenches and storm piping to be protected from roots with a root barrier. 2) Roof drain downspouts are to be connected to the proposed N drainage system. Contractor to provide engineer with downspout locations prior to installation of drainage system. 3) Exfiltration trench design uses an assumed value of hydraulic conductivity. Client may obtain a site specific test for hydraulic conductivity prior to exfiltration trench installation. 0 4 8 16 32 4) Contractor shall mill and overlay all roadway cuts a minimum Revisions of 50 ft. on either side of the excavation the entire width of each affected lane. 1 05/21/2020 5) Contractor is responsible for installing and maintaining erosion Scale: 1/8" = 1'-0" 2 3 07/23/2020 control measures during construction. Proposed Driveway 4 6) Video inspection of storm drainage system required prior to 5 6 installation of sod. 7 8 9 10 Chad M. Gruber This item has been electronically signed and sealed by Chad M. Gruber on the date adjacent to the seal using a SHA authentication code. Printed copies of this document are not considered signed and sealed and the SHA authentication code must be verified on any electronic copies. 135' FL P.E. No. 57466 Via Bellaria Sheet No. Plan Background from Site Plan by Lynn McColl, LLC Received 7/14/20 C-1 ARCOM #B-020-2020 Z-20-00275 © 2020 Gruber Consulting Engineers, Inc.
N88°52'14"W 118.50 48 HOURS BEFORE DIGGING CALL 1-800-432-4770 SUNSHINE STATE ONE CALL OF FLORIDA, INC. Contractor is responsible for obtaining location of existing utilities prior to commencement of construction activities. G CE N01°07'46"E Intracoastal Waterway 33.10' Via Serena Clarendon Ave. WEST PALM BEACH, FL 33401 2475 MERCER AVE., SUITE 305 Gruber Consulting Site office@gruberengineers.com Atlantic Ocean Engineers, Inc. PHONE: 561.312.2041 FAX: 561.537.7229 Via Bellaria Via Del Lago N Proposed S88°52'14"E South Ocean Blvd. Via Palma Pool 16.50' Algoma Rd. Kings Rd. Woodbridge Rd. 04/17/2020 2020-0037 1/8"=1'-0" Project Information KM CG Location Map N.T.S. Checked By Project No. Issue Date Drawn By Notes: Scale 1) The height of a silt fence shall not exceed 36". 2) Filter fabric shall be purchased in a continuous roll cut to the length of the barrier to avoid the use of joints. 3) Posts shall be spaced a maximum of 10' apart at the barrier location and driven securely into the ground a minimum of 12". When extra strength fabric is used without the wire support fence, post spacing shall not exceed 6'. 4) A trench shall be excavated approximately 4" wide and 4" deep along the line of posts and upslope from the barrier. Palm Beach, Florida 5) When standard strength filter fabric is used, a wire mesh support fence shall be fastened securely to the upslope side of the posts using heavy duty wire staples at least 1" long, tie wires, or hog rings. The wire shall 165.00' Conceptual Construction Staging & Parking and Erosion Control Plan For: extend into the trench a minimum of 2" and shall not extend more than Addison Developement Group Inc. 36" above the original ground surface. 6) The standard strength filter fabric shall be stapled or wired to the fence, and 8" of the fabric shall be extended into the trench. The fabric shall not extend more than 36" above the original ground surface. 7) The trench shall be backfilled and the soil compacted over the filter fabric. Proposed Two Story Residence N01°07'46"E SILT FENCE DETAIL Min. F.F. Elev. = 7.33 NAVD N.T.S. Legend 119.40' S01°07'46"W Proposed Driveway Proposed 171 Via Bellaria Garage N SILT FENCE SECTION N.T.S. 0 4 8 16 32 Revisions 1 05/21/2020 Scale: 1/8" = 1'-0" 2 3 07/23/2020 Proposed Driveway 4 5 Notes: 6 7 1) Contractor is responsible for installing and maintaining erosion 8 control measures during construction. 9 ATTACHING TWO SILT FENCES 10 N.T.S. Chad M. Gruber This item has been electronically signed and sealed by Chad M. Gruber on the date adjacent to the seal using a SHA authentication code. Printed copies of this document are not considered signed and sealed and 135' the SHA authentication code must be verified on any electronic copies. FL P.E. No. 57466 Via Bellaria Sheet No. Plan Background from Site Plan by Lynn McColl, LLC Received 7/14/20 EC-1 ARCOM #B-020-2020 Z-20-00275 © 2020 Gruber Consulting Engineers, Inc.
ZONE X N88°52'14"W 118.50' 15.00' N01°07'46"E 33.10' 15.00' 49.00' 49.00' S88°52'14"E 16.50' ZONE AE (ELEV. 6) I I ZONE X I 37.17' I AFFECTS THE PROPERTY AND PLOTTED HEREON. AFFECTS THE PROPERTY, HOWEVER BLANKET IN NATURE AND NOT PLOTTABLE, ALLOWS FOR THE PLACEMENT OF POLES TO SUPPORT TELEPHONE LINES ETC. TO 15.00' 'INTERFERE IN AS SMALL DEGREE AS POSSIBLE'. DOES NOT AFFECT THE PROPERTY, PLOTTED HEREON FOR CLARITY. AFFECTS THE PRIVATE ROADWAY KNOWN AS VIA N01°07'46"E 165.00' BELLARIA WHEREAS IT IS GRANTED THEREIN THE RIGHTS TO WEST PALM BEACH WATER COMPANY THE RIGHTS TO LAY PIPES IN ALONG OR ACROSS THE SAID PRIVATE ROADWAY. VIA BELLARIA, AS NOW LAID OUT AND IN USE, 152.50' PLOTTED AND SHOWN HEREON. NOT A SURVEY MATTER. VIA BELLARIA AS NOW LAID AND IN USE SHOWN HEREON. S01°07'46"W 131.90' 28.00' AFFECTS THE PROPERTY, PLOTTED HEREON. 119.40' ZONE AE ZONE X ZONE AE ZONE X (ELEV. 6) (OTHER) (ELEV. 6) I I (OTHER) I I I 15.00' 28.00' 39.25' 37.00' 37.00' 35.00' ZONE X 12.50' 12.50' S88°52'14"E 135.00' KESHAVARZ ASSOCIATES Civil Engineers ● Land Surveyors 711 North Dixie Highway, Suite 201 West Palm Beach, Florida 33401 Tel: (561) 689-8600 Fax: (561) 689-7476