Optical Fibre Enabling 5G and FTTx - Sudipta Bhaumik - STL Tech
←
→
Page content transcription
If your browser does not render page correctly, please read the page content below
stl.tech Optical Fibre Enabling 5G and FTTx Sudipta Bhaumik Head – Applications and Standards Engineering STL - Sterlite Technologies Limited © 2021-2022 Sterlite Technologies Limited
Agenda 1 Data and OF/C Consumption Trends 2 Next Gen networks – Both 5G and FTTH will play a role in that space 3 Next Gen – One Fibre Network and High-Density Cables © 2021-2022 Sterlite Technologies Limited 2
Data Consumption Trends Key Digital Transformers By 2022 26% More Internet More Faster Devices & Broadband Faster Video IP traffic growth rate (2017-22) Users Connections Speeds Viewing 46% Mobile Data traffic growth rate (2017-22) 2017 3.4 18.0 39 75% of Billion Billion Mbps Traffic 4.8 28.5 75.4 82% of 2022 Billion Billion Mbps Traffic Gaming 82% Exabytes per Month (1%, 4%) File Sharing Internet traffic will be in form of Video (7%, 2%) Web/Data (17%, 12%) 29% IP VOD/ Managed IP Video (20%, 11%) IP Video traffic growth rate Internet Video (55%, 71%) Source: Cisco Visual Networking Index © 2021-2022 Sterlite Technologies Limited 3
Unabated Growth in Demand of Optical Fiber Optical fibre cable deployment Increasing Deployment Speed has outpaced the growth of world economy by ~5x 5x 13.9 38 5 3 2 1.5 years years years years years 1 Bn Fkm 2 Bn 3 Bn 4 Bn 5 Bn 1970 2008 2013 2016 2018 -2008 -2013 -2016 -2018 -2020 2.9 1.3 Population GDP Optical (World Fibrer economy) cable World’s rate of deployment of 1Bn fkm cable has shrunk 20 years CAGR: 1997 to 2017 drastically from 38 years to less than 2 years Source : CRU © 2021-2022 Sterlite Technologies Limited 4
Fiberization in India • Around 1500 Mkm fibre need to be deployed to reach 1.3 fibre/Capita • Deployment rate in India should reach 150 MFkm/year within next 5 years to achieve 1.3 Fkm/Capita by 2035 © 2021-2022 Sterlite Technologies Limited 5
OFC Installation in 2021 North America China Europe 16% 49% 13% 13% APAC *Other Regions 9% Excluding China Region wise share of optical fibre cable installed in 2021 © 2021-2022 Sterlite Technologies Limited 6
Single Mode Fibre (SMF) Mix 11% G.657. A2 1% 10% 23% G.657. A1 3% 20% 1% G.652. A/B 7% 6% 63% G.652. C/D 88% 25% *Others – 1%, 2% 2021 2010 © 2021-2022 Sterlite Technologies Limited 7
Covid has Significantly Accelerated this Journey Study and Work from Home have become second nature Subscriber Additions (Mn) zoom isisnow worth more 5G zoom now worth 12% of the Global mobile Traffic will be than world’s more 7 big airlines than world’s 7 big on 5G by 2022, which would generate airlines 21 GB traffic/month per connection FTTH By 2022, global fixed broadband speeds will reach 75.4 Mbps, up from 39 Mbps in 2017. 5G and FTTH would play a pivotal role to sustain the increased speed and data consumption requirement Source: Apptopia, IDC, Statista © 2021-2022 Sterlite Technologies Limited 8
Agenda 1 Data and OF/C Consumption Trends 2 Next Gen Networks- Both 5G and FTTH will play a role in that space 3 Next Gen – One Fibre Network and High-Density Cables © 2021-2022 Sterlite Technologies Limited 9
ITU-R Triangle And 4G vs 5G Enhanced Mobile Broadband Parameters 4G 5G Enhancement Gigabytes in a second Latency 10 ms 1 ms 10 x 3D Videos, UHD Screens Smart Home/ Building Peak Data Rate 1 Gbps 20 Gbps 20 x Work and Play in the cloud AR User 10 Mbps 100 Mbps 10 x Voice Experienced Data Rate Industry Automation Connection 10 5 10 6 10 x Mission Critical Density devices / km2 devices / km2 Smart City Application Mobility 350 km / hr 500 km / hr 43% Self Driving Car Area Traffic 0.1 Mbps/m2 10 Mbps/m2 100 x Massive Machine Type Ultra-reliable and Low Latency Capacity Communications Communications © 2021-2022 Sterlite Technologies Limited 10
5G Frequency Bands LOW BAND MID BAND HIGH BAND mmW Unlicense d 700-2100 MHz 2600-3800 MHz 3800-7000 MHz 26 GHz 60 GHz Backhaul/ 3G, 4G and 5G Re-farmed “Real” 5G mobile (3.6GHz) and Fixed Wireless Residential BB Macro Macro and Small Mainly Small Cell / Micro Fixed / Sites Cell/Micro Sites Sites Wireless Low Bandwidth / Longer Reach / Good Penetration High Bandwidh / Shorter Reach / Bad Penetration 1.8 GHz ~ 22 dB loss ~ 20 dB loss 3.5 GHz mmW ~50 dB loss © 2021-2022 Sterlite Technologies Limited 11
Evolution Of PON Standards ITU and IEEE PON Standards History Standard Started Deployment Begins Standard Finished Deployment Ends A/B-PON 622M/155M G.983.x G-PON 2.5G/1.25G G.984.x ITU XG-PON 10G/2.5G G.987.x NG-PON2 4λ 10G/10G G.989.x XGS-PON 10G/10G G.9807.x HS-PON 50G/25G G.hsp.X NG_EPON 25G/25G 802.3ca 10GE-PON IEEE E-PON 10G/10G 802.3av 1G/1G 802.3ah 2000 2005 2010 2015 2020 2025 © 2021-2022 Sterlite Technologies Limited 12
PON Spectrum: Wavelength Evaluation © 2021-2022 Sterlite Technologies Limited 13
A Converged Topology for FTT-5G The Most Effective Approach V band + Sub 6GHz FSO or E band Fiber ring FSO or E band Residential Enterprises Small Cells E band , Sub 6GHz Or licensed microwave Hospital FSO or E band V band or Sub 6GHz Fiber Cell Tower Rural 14 © 2021-2022 Sterlite Technologies Limited © 2021-2022 Sterlite Technologies Limited
Shorter Range Of 5G- More Cells and More Fibres Small Cell Requirements For Full 5G Commitment Indoor Fibre Infra For Large Building 10 Km 10 Km 10 Km 10 Km 10 Km 10 Km 1 Site 1 Site 1 Site Every 10 KM Every 2 KM Every 0.5 KM 25x 10x CELL DENSITY (Cell/ 100 Sq.Km.) CELL DENSITY (Cell/ 100 Sq.Km.) CELL DENSITY (Cell/ 100 Sq.Km.) 1 Cell 5x5= 25 CELLS ~250 CELLS 3G To 4G = At Least 25x Fibres Full Fibre Infrastructure 4G To 5G = At Least 10x Fibres Fibre To The Ceiling (FTTC) © 2021-2022 Sterlite Technologies Limited 15
Example Of Converged Physical Layer 825 Fibre strands (incl. 20% extra for maintenance and future uncertainties) EXAMPLE: Suburban area with 20,000 population per sq. km. density Home Enterprises Small Cells No. of Persons in a Household 4 Number of Enterprises 20 Street Length (km) 9 No. of Households 5000 Households that can afford 75 % Market Share of an operator 50 % Distance between Poles (km) 0.1 Market Share of an operator 30 % Scalable Bandwidth Differentiated 2 Gbps (Peak) P2MP & High SLA P2P Services MIMO/ (XGPON,SGXPON, Ultra Low Latency - < (MPLS,MEN,OTN) For Mobility & mmwave NGPON2) 1 ms Smart City 141 Strands 20 Strands 540 Strands 1125 Homes 10 Enterprises * 1 Pair of 90 Poles * 3 Pairs of Fiber/Enterprise Fiber/Pole 8 Homes/GPON Port Source: Sterlite Estimates © 2021-2022 Sterlite Technologies Limited 16
Agenda 1 Data and OF/C Consumption Trends 2 Next Gen Networks- Both 5G and FTTH will paly a role in that space 3 Next Gen – One Fibre Network and High-Density Cables © 2021-2022 Sterlite Technologies Limited 17
The Fiberization Challenges + A B Attenuation Bend Signal Decay Sensitivity Signal Leakage Source: GSMA, Canalys, Company & Industry Estimates © 2021-2022 Sterlite Technologies Limited 18
“Recommended” Fibre Type in a Typical Network Broadband Network CO Gateways Cu Core Router DSL Metro Edge Wireless Access Ethernet CO Switch FTTB OLT FTTH Core Network Metro Network Access Network G.652.D G.652.D G.652.D G.655 G.655/ 656 G.657.A1/A2/B2/B3 © 2021-2022 Sterlite Technologies Limited 19
ITU-T G.652.D is the “Standard” fibre type today! Common Fibre type across all network sections TODAY : ITU-T G.652.D compliant Broadband Network CO Gateways Cu Core Router DSL Metro Edge Wireless Access Ethernet CO Switch FTTB OLT FTTH Core Network Metro Network Access Network G.652.D G.652.D G.652.D G.655 G.655/ 656 G.657.A1/A2/B2/B3 © 2021-2022 Sterlite Technologies Limited 20
Bend Insensitive Fibre (BIF) is the Future Common Fibre type across all network sections IN FUTURE : ITU-T G.657.A2 compliant Broadband Network CO Gateways Cu Core Router DSL Metro Edge Wireless Access Ethernet CO Switch FTTB OLT FTTH Core Network Metro Network Access Network G.652.D G.657.A1/A2 G.652.D G.657.A2 G.652.D G.657.A2/B3 G.655 G.655/ 656 G.657.A1/A2/B2/B3 © 2021-2022 Sterlite Technologies Limited 21
Beginning of Life (BOL) optical link loss Optical Loss Management Beginning of Life (BOL ) Loss Optical Fibre Fiber Splice Connector Bend Loss Incidental Cable Drum Loss Loss Losses Attenuation Why link loss increases from BOL value? Accidental/ BOL Optical Link Fiber Aging, Water Fiber Splice Loss Unplanned Fiber Loss Ingress /Cable Cut Bend Loss Incidental Losses © 2021-2022 Sterlite Technologies Limited 22
What is Attenuation Attenuation refers to signal loss along the length of the fibre. Attenuation happens due to absorption and scattering of light signal inside the core © 2020-2021 Sterlite Technologies Limited 23
What is Bend Sensitivity Bend Insensitive Fibre provide more than 10x reduced Macro Bend Loss Microbend Bend Performance Unsafe to use G652.D vs G.657.A2 Under extreme Macroben conditions ds Source: Sterlite Tech calculations © 2020-2021 Sterlite Technologies Limited 24
Accidental Bends in Real Life Scenarios Abuse In Optical Fibre Ideal Condition 25
Most Common Origin Of Optical Loss Bend loss before & after rectification Bend loss before & after rectification 1.400 3.000 1.169 2.464 2.480 1.200 2.500 2.218 0.934 1.000 2.000 0.800 0.713 1.500 0.600 1.000 0.400 0.200 0.104 0.500 0.000 0.000 0.000 0.000 0.000 0.000 0.000 1310 nm 1550 nm 1625 nm 1310 nm 1550 nm 1625 nm F 04 F13 Loss before rectification (dB) Loss after rectification (dB) Loss before rectification (dB) Loss after rectification (dB) © 2021-2022 Sterlite Technologies Limited 26
Impact on Reach and New Technology Adoption Increasing geographical spread Newer Technology & Next Gen PONs More no. of tight bends & turns Exposure to higher wavelengths Applications METRO & DOCSIS & HFC LONG HAUL FIBRE TO THE X Macro Bend Loss increase 2.5X 3X 4X 2X Technology upgradation DWDM/CWDM DWDM/CWDM Downstream Downstream Downstream 10G-PON 40G-PON Upstream RF-Video C-Band G-PON G-PON L-Band RFoG 1550 1610 1560 1625 1490 1577 1490 1603 nm nm nm nm nm nm nm nm Wavelength increase 60 nm 65 nm 87 nm 113 nm © 2021-2022 Sterlite Technologies Limited 27
ITU-T G.657.A2 Bend-insensitive Fibre ITU-T removed the mention of “Access …and revised attribute specifications Network” for bend insensitive fibre… for compliance with legacy G.652.D fibre “ ITU-T G.657.A1/A2 2012 fibre can be used for all networks where ITU-T G.652.D fibre is ” specified 2016 Source: pg. 7, ITU-T G.657 2016 recommendation literature scope Source: ITU-T literature on G.657 fibre © 2021-2022 Sterlite Technologies Limited 28
The Cascading Effect Of Low Bend Loss Microbend Loss Test (IEC TR 62221, method B, Fixed drum method ) Source: ITU-T literature on G.657 fibre © 2021-2022 Sterlite Technologies Limited 29
Reduced Operational Expense With Bend Insensitive Fibre ~6 – 7 repairs ~17 – 18 repairs 10+ years increased network life* Lower loss increases repair resilience enhancing overall network life Assumptions: - Accidental 15mm bend at time of repair - Average link length : 14kms, 1000 links per sim and 51 sims in total - Splice loss: 0.1 dB (G.652.D vs G.657.A2) - Cuts/1000km/month: 10 - BOL drum attenuation: 0.20/0.21/0.22/0.23 dB/km © 2021-2022 Sterlite Technologies Limited 30
ITU-T G.657.A2 fibre- The New Standard 1. 2. 3. Reduced Bend Loss Enhanced Network Reach Higher Splitting Ratio 5. 4. 6. Splice Compatible With For a Futureproof Network Network Lifetime Increment Legacy Fibre © 2021-2022 Sterlite Technologies Limited 31
The Fiberization Challenges + A B C Attenuation Bend Compatibility Signal Decay Legacy and Future Sensitivity Technology Signal Leakage Source: GSMA, Canalys, Company & Industry Estimates © 2021-2022 Sterlite Technologies Limited 32
Compatibility with Legacy Network and Future Technology G.652.D MFD of Typical G.657. A2: 8.6 micron MFD of Legacy G.652. D: 9.1 micron MFD Mismatch Actual Splice Loss 0.005dB A2 to D Apparent Loss 0.12dB D to A2 Apparent Loss: -0.22dB © 2020-2021 Sterlite Technologies Limited 33
Legacy Fibre Compatible G.657.A2 Fibre The Installer’s Fibre World’s 1st G.657.A2 fibre which is compatible with legacy networks built on G.657.A1 and G.652.D Minimal Increased Network Cost Saving Future Ready Splice Loss Life 9.1 MFD ensures Low bend loss - Bend Insensitive – Compact Superior Macro Bend seamless splicing Provision for more Splice Box and Manholes performance at higher 34 34
The Fiberization Challenges A B C D Attenuation Bend Compatibility Duct Space Signal Decay Legacy and Future Optimize Limited Sensitivity Technology Space Signal Leakage Source: GSMA, Canalys, Company & Industry Estimates © 2021-2022 Sterlite Technologies Limited 35
Limited Duct Space 80% Cost share of civil work in a Cable Deployment Project Rest 20% constitutes Cables, Ducts and supplementary products To meet this exponential growth able eployment ro e t Need 10X Fibre In the same available duct space ~80% 6 Minimize the size of Cable as per requirement and provision for future requirement Maximize Fibre Count on the basis of forecasted future demand ren aterial ost ermit and t ost o isti s otal ost of i in Way lea es ners ip © 2020-2021 Sterlite Technologies Limited 36
Next Generation Ribbon Technology Modern networks require more fiber per cable and Minimize new duct installation and construction Better TCO from one-time deployment with compact cables in choked ducts Intelligently Bonded Easy Traditional flat ribbon Ribbon Cable EASE OF SPLICING Traditional Loose Tube Cable Micro Cable Larger diameter COMPACTNESS OF CABLE Highly compact Traditional Loose Tube Traditional Flat Ribbon Intelligently Bonded Micro Cable Cable Cable Ribbon Cable • Slimmer Jacket & 200um fibre • Ribbon, bundle of Fibres • Improved form factor due to Splicing is difficult and time reduces cable diameter expedites splicing process bond design consuming in high fiber • Splicing is still time consuming • Unoptimized cable space with • Collapsible ribbon transforms count cables flat ribbons in a round cable into flat ribbon for fast splicing © 2020-2021 Sterlite Technologies Limited 37
Celesta – Intelligently Bonded Ribbon Cable Intermittent Bonded Ribbon Industry’s lowest attenuation in Fiber Ribbon Cables › Made using G.657.A2 bend insensitive optical fibre Splice fast and easy › mass splice with new and existing ribbon solutions › Single fiber splice compatible – safe and fast ribbon separation into 12 loose fibers Easy to install › blow optimized micro ribbon cable, but at same time robust enough for pull installation › easy ribbon routing/handling in splice tray – zero preferential ribbon bend, Saves installation cost › Saves duct cost - IBR roll up and fill the space inside of a cable efficiently allowing for the highest fiber counts › Accessories miniaturization - Micro ribbon cables and ultra ..upto 6912F ribbon cables bend tightly © 2020-2021 Sterlite Technologies Limited 38
Celesta - Maximise Duct Space Utilization 4.5X 2X 32% Faster Blow Overall Cost More Fibre* * As compared with MTL cable Installation Savings © 2019-2020 Sterlite Technologies Limited 39
Easy install - Innovative Blow Optimised Ribbon Cable Design AIR BLOWN INSTALLATION CABLE TEST ROUTE 2000m Single shot blow in super tough the UK Telco test track < 35 mins UK Telco approved 432F G657.A2 STL IBR © 2021-2022 Sterlite Technologies Limited 40
Global innovations for Indian deployment scenarios Enabling Future Readiness at Lowest Total Cost of Ownership + Backward Compatible High Density Ribbon Cable G657A2 Fibre Intelligently Bonded Ribbon (72F - 6912F) Faster deployment of Higher density network - future proof bend 100% existing duct Optical Connectivity capacity augmentation resilient network Global leader in E2E optical physical layer solutions © 2021-2022 Sterlite Technologies Limited 41
Q&A
beyond tomorrow www.sterlitetech.com
You can also read