Grundfos UP XL maintenance-free circulators - GRUNDFOS INSTRUCTIONS

Page created by Gene Sherman
 
CONTINUE READING
GRUNDFOS INSTRUCTIONS

Grundfos UP XL
maintenance-free circulators
Installation and operating instructions

       3191277

                  Conforms to UL STD 514C
                  Certified to CSA STD C22.2 No. 18.2
English (US) Installation and operating instructions
(QJOLVK 86

              Original installation and operating                 be liable for damage or wear to products caused
              instructions.                                       by abnormal operating conditions, accident,
                                                                  abuse, misuse, unauthorized alteration or repair,
              CONTENTS                                            or if the product was not installed in accordance
                                                          Page    with Grundfos' printed installation and operating
                                                                  instructions.
              1.    Limited warranty                          2   To obtain service under this warranty, the
              2.    Safety warning                            2   defective product must be returned to the
              2.1   Read this booklet                         2   distributor or dealer of Grundfos' products from
              2.2   Electrical work                           2   which it was purchased together with proof of
                                                                  purchase and installation date, failure date, and
              3.    Pre-installation checklist                3   supporting installation data. Unless otherwise
              3.1   Confirm you have the correct pump         3   provided, the distributor or dealer will contact
              3.2   Check the condition of the pump           3   Grundfos or an authorized service station for
              3.3   Verify electrical requirements            3   instructions. Any defective product to be
              3.4   Pumped liquid requirements                3   returned to Grundfos or a service station must
                                                                  be sent freight prepaid; documentation
              4.    Installation procedures                   4   supporting the warranty claim and/or a Return
              4.1   Piping considerations                     4   Material Authorization must be included if so
              4.2   Changing the terminal box position        5   instructed.
              4.3   Electrical connection                     6   GRUNDFOS WILL NOT BE LIABLE FOR ANY
              4.4   Insulation shell                          7   INCIDENTAL OR CONSEQUENTIAL
                                                                  DAMAGES, LOSSES, OR EXPENSES ARISING
              5.    Starting the pump                         8
                                                                  FROM INSTALLATION, USE, OR ANY OTHER
              5.1   Vent the piping system                    8   CAUSES. THERE ARE NO EXPRESS OR
              5.2   Speed selection                           8   IMPLIED WARRANTIES, INCLUDING
              6.    Troubleshooting                           9   MERCHANTABILITY OR FITNESS FOR A
              6.1   Fault finding chart                       9   PARTICULAR PURPOSE, WHICH EXTEND
                                                                  BEYOND THOSE WARRANTIES DESCRIBED
              6.2   Preliminary checks                       10
                                                                  OR REFERRED TO ABOVE.
              6.3   Current measurement                      10
                                                                  Some jurisdictions do not allow the exclusion or
              6.4   Insulation resistance
                                                                  limitation of incidental or consequential
                    (lead-to-ground)                         10
                                                                  damages and some jurisdictions do not allow
              6.5   Winding resistance (line-to-line)        11   limit actions on how long implied warranties may
              6.6   Resistance charts                        11   last. Therefore, the above limitations or
              7.    Replacing components                     12   exclusions may not apply to you. This warranty
              7.1   Removing the pump head                   12   gives you specific legal rights and you may also
                                                                  have other rights which vary from jurisdiction to
              7.2   Fitting the pump head                    12
                                                                  jurisdiction.
              7.3   Replacing the terminal box or
                    capacitor                                13
                                                                  2. Safety warning
              8.    Additional technical data                13
              9.    Disposal                                 13   2.1 Read this booklet
                                                                  This booklet is designed to help a certified
                                                                  installer to install, begin operation of, and
              1. Limited warranty                                 troubleshoot the Grundfos Small UP and UPS
                                                                  pumps.
              Products manufactured by GRUNDFOS PUMPS             Following the instructions will ensure safe,
              CORPORATION (Grundfos) are warranted to             trouble-free operation.
              the original user only to be free of defects in
              material and workmanship for a period of 36         This booklet should be left with the owner of the
              months from date of manufacture. Grundfos'          pump for future reference and information
              liability under this warranty shall be limited to   regarding its operation. Should the owner
              repairing or replacing at Grundfos' option,         experience any problems with the pump, a
              without charge, F.O.B. Grundfos' factory or         certified professional should be contacted.
              authorized service station, any product of
              Grundfos' manufacture. Grundfos will not be         2.2 Electrical work
              liable for any costs of removal, installation,      All electrical work should be performed by a
              transportation, or any other charges which may      qualified electrician in accordance with the
              arise in connection with a warranty claim.          latest edition of the National Electrical Code,
              Products which are sold but not manufactured        local codes and regulations.
              by Grundfos are subject to the warranty
              provided by the manufacturer of said products
              and not by Grundfos' warranty. Grundfos will not

              2
3.2 Check the condition of the pump

                                                                                                                (QJOLVK 86
           Warning!
                                                       The pump’s shipping carton is specially
           A faulty motor or wiring can cause          designed around the pump during production to
           electrical shock that could be              prevent damage.
           fatal, whether touched directly or          As a precaution, it should remain in the carton
           conducted through standing                  until you are ready to install it. At that point, look
           water. For this reason, proper              at the pump and examine it for any
           grounding of the pump to the                damage that may have occurred during
           power supply's grounding                    shipping.
           terminal is required for safe
           installation and operation.                 Examine any other parts of the shipment as well
                                                       for any visible damage. Once the pump has
           In all installations, the                   been removed from the box, care should be
           above-ground metal plumbing                 taken NOT to drop or mishandle the pump.
           should be connected to the power
           supply ground as described in the           Box contents:
           National Electrical Code. All               • one pump
           wiring must comply with the                 • two gaskets (flanged units only)
           National Electrical Code, state,
           and local regulations.                      • one Installation and Operation Instruction
                                                         (I&O).

3. Pre-installation checklist                          3.3 Verify electrical requirements
                                                       Verify the electrical supply to be certain the
3.1 Confirm you have the correct pump                  voltage, phase and frequency match that of the
•   Read the pump nameplate to ensure it is the        pump motor. The proper operating voltage and
    one you ordered.                                   other electrical information can be found on the
•   Compare the pump's nameplate data and its          pump nameplate.
    performance curve (for head, gpm, etc.) with       This pump’s motor is designed to run on
    the application in which you plan to install it.   + / - 10 % of the nameplate-rated voltage.
•   Will the pump do what you expect it to do?
                                                       3.4 Pumped liquid requirements
3.1.1 Pump to system type
      recommendations                                              Warning!
• Open systems (i.e. potable water):                               The Grundfos Small UP/UPS
    Stainless steel or bronze volute (pump                         pump is intended for use with
    housing) only.                                                 water only. The pump must not be
• Closed systems (i.e. airless, non-potable                        used for the transfer of
    water): Cast iron, stainless steel, or bronze                  flammable liquids such as
    volute (pump housing).                                         diesel oil, gasoline, and similar
Other considerations regarding Grundfos Small                      liquids.
UP and UPS pumps:                                                  The pump is not for pool or
• These pumps are intended for indoor use                          marine use.
    only.                                              The pump can be used to circulate:
• If installed outdoors the pump must be               • Potable hot water.
    protected by an appropriate, well ventilated,      • Water containing glycol for hydronic heating
    water-tight enclosure to keep out moisture              (see section 7. Additional technical data for
    and dirt.                                               additional limitations).
• Minimum ambient temperatures must be no              • Cooling water.
    lower than 33 °F (1 °C).
                                                       In domestic hot-water systems it is advisable to
• For ambient and fluid temperature see                use stainless steel pump housing versions of
    sections 3.4 Pumped liquid requirements            this pump.
    and 7. Additional technical data.
                                                       All pump types (stainless, bronze or cast iron
                                                       pump housing) should not be used in water with
                                                       a degree of hardness lower than 14 grains per
                                                       gallon of hardness.
                                                       Fluids should be clean and should not contain
                                                       solid particles, fibers, or mineral oils.
                                                       If the pump is installed in a heating system, the
                                                       water should meet the requirements of accepted
                                                       standards on water quality in heating systems.
                                                       The fluid should not contain solid particles,
                                                       fibers, or mineral oils.

                                                                                                            3
The pump is lubricated and cooled by the                    4. Installation procedures
(QJOLVK 86

              liquid being pumped. Therefore, the pumped
              liquid must always be allowed to circulate
              through the pump.
                                                                                     Warning!
                                                                                     Never make any connections in the
              Extended periods without circulation will cause
                                                                                     pump terminal box unless the
              premature wear to the bearings and excessive
                                                                                     electrical supply has been
              motor heat.
                                                                                     switched off.
              The pumped liquid must meet the temperature
                                                                                     The pump should not be
              requirements listed in the following charts.
                                                                                     connected to the electrical
              Note: Fluid must never be allowed to freeze                            system until it has been properly
              during non-operational periods.                                        installed in the piping system.
                                                                                     Risk of electrical shock — this
                                     Open systems
                              (domestic, potable hot water):
                                                                                     pump has not been investigated
                                                                           &DXWLRQ   for use in swimming pool or
                                            Fluid             Ambient                marine areas.

              Min.                    36 °F (2 °C)        33 °F (1 °C)    4.1 Piping considerations
                                                                          When making piping connections, be sure
              Max.                    < 149 °F (65 °C)    100 °F (38°C)
                                                                          to follow the piping manufacturer’s
                                                                          recommendations and all code requirements for
                                                                          piping material.
                              Caution!
                                                                          Thoroughly clean and flush all dirt and
                              In domestic hot-water systems,              sediment from the system before attempting to
                              it is recommended to keep the               install the pump.
                              liquid temperature below 149 °F
                              (65 °C) to eliminate the risk of lime       4.1.1 Location in the piping line
                  &DXWLRQ
                              precipitation.                              The pump should never be located at the
                                                                          lowest point of the piping system (where dirt and
                                 Closed systems                           sediment collect), nor should it be located at the
                   (non-potable heating or cooling airless fluid):        highest point of the piping system (where air
                                                                          accumulates).
                             Pump
                                                 Fluid          Ambient
                             models                                                  Warning!
                                                 36 °F           33 °F               The pump must be positioned
              Min.              All
                                                 (2 °C)          (1 °C)              so that someone cannot
                                                230 °F           100 °F              accidentally come into contact with
                            UPS 26-150                                               the hot surfaces of the pump.
                                               (110 °C)          (38°C)
                                                230 °F           100 °F   When installing the pump into the piping
              Max.          UPS 43-100
                                               (110 °C)          (38°C)   system, Grundfos recommends that pressure
                                                212 °F           100 °F   gauges be installed in the inlet and discharge
                            UPS 50-60                                     flanges or pipes. This will allow the pump and
                                               (100 °C)          (38°C)
                                                                          system performance to be checked.
                                                                          Do not block the pipe plugs in the pump
                                  Water and glycol mix:
                                                                          housing flanges by locating the terminal box
              Max.           50 % glycol @ 15 °F (-9.5 °C) fluid          over these plugs.
              (Hydraulic performance change can be expected.)

              4
4.1.2 Mounting positions                                           4.2.1 Rotating the terminal box

                                                                                                                          (QJOLVK 86
The arrows on the pump housing indicate the                        To change the position of the terminal box,
direction of water flow. The pump may be                           follow these steps:
installed in vertical or horizontal piping, but the                1. Remove the four (5 mm) allen-head screws
motor shaft must always remain                                         holding the pump head onto the pump
horizontal, as shown in fig. 1.                                        housing.
                                                                   2. Carefully lift/slide the pump head out and
                                                                       away from the pump housing. Next rotate the
                                                                       pump head and locate the terminal box in the
                                                                       desired position. The terminal box can be
                                                                       rotated in steps of 90 °. Review
                                                                       fig. 1 and fig. 2 for possible/permissible
                                                                       positions. DO NOT locate the terminal box
                                                                       beneath the pump.

                                                                               Caution!
                                                                               Use caution as the rotor
                                                                               assembly can fall out of the pump
                                                                               head or pump housing if the pump
                                                                     &DXWLRQ   head is pulled too far away from
                                                                               the pump housing.
                                                  TM04 5646 3609

                                                                   3. Make sure the O-ring is properly seated in
                                                                       the pump housing.
                                                                   4. Replace the pump head onto the pump
                                                                       housing.
                                                                   5. Diagonally tighten the 5mm allen-head
                                                                       screws evenly.
  Fig. 1      Installation positions                                   Torque to: 7 ft lbs. / 9.5 Nm.
4.1.3 Terminal box position                                        6. Check to ensure the rotor turns freely. Do
                                                                       this by removing the vent plug in the
At the bottom of the stator, closest to the pump                       middle of the pump nameplate. Insert a
housing, there are three drain holes to allow                          medium-size, flat-blade screwdriver into the
condensed water to escape. The drain holes                             slot at the exposed end of the shaft. Gently
shall not be blocked for any reason and one                            turn the shaft. If it does not turn easily,
drain hole must always point downward.                                 repeat steps 1 through 5 above.
There is not a drain hole directly below the                           If the rotor spins freely, proceed to step 7. Do
terminal box; therefore the terminal box must be                       not put the vent plug back into the pump until
positioned in one of the positions shown in fig. 1                     the end of step 9.
or fig. 2.                                                         7. The position of the nameplate can be
                                                                       changed by easing the outer edge of the
4.2 Changing the terminal box                                          plate at the cutout with a screwdriver.
    position                                                           Turn the nameplate to the required position
                                                                       and push into place.
            Warning!
                                                                   8. Follow electrical instructions in section 3.3.
            Before starting any work on this
            circulator, be sure electrical                         9. Refill the system, open the isolation valves
            supply has been switched off                               and vent the system. Also allow air to vent
            and it cannot be accidentally                              out of the pump; once water flows out the
            switched on.                                               vent hole, replace the vent plug removed in
                                                                       step 6. See additional instructions in
If the pump is already installed in the system,                        section 4.1.
the system must be drained or the isolation                        10. Fig. 2 shows acceptable terminal box
valves on both sides of the pump must be closed                        positions along with recommended drip
and the pressure released/relieved by removing                         loops (dashed lines) in the electrical wiring
the vent plug.                                                         harness based on entry point.
            Caution!
            Exercise caution when draining
            the system or removing the vent
            plug as the fluid in the system may
  &DXWLRQ   be scalding hot and under
            pressure.
Only after the pressure has been relieved and
the pump drained should you proceed with the
next steps.

                                                                                                                      5
Proper operating voltage and other electrical
(QJOLVK 86

                                                                                      information can be found on the pump
                                                                                      nameplate attached to the top of the motor.
                  Terminal box
                                                                                      • The motor is thermally protected on all three
                  position A                                                              speeds and no additional external
                                                                                          protection is needed.
                                                                                      • See fig. 3 for proper grounding and supply
                                                                                          power connection locations (115V and
                                                                                          208-230V).
                                                                                      • The terminal connections are toggle/lever
                                                                                          push design. Push the lever down and insert
                  Terminal box                                                            the field wiring. Push the lever down and pull
                  position B
                                                                                          to remove wires.
                                                                                      • Next, use care when installing the terminal
                                                                                          box cover with speed switch (rough
                                                                                          handling can damage the run light LED on
                                                                                          the printed circuit board (PCB)). Insert the
                                                                                          Phillips head screw through the cover and
                                                                                          tighten to a snug fit.
                                                                     TM04 5636 3609

                  Terminal box                                                        • An external "Drip Loop" is recommended in
                  position C                                                              the electrical wiring harness; see fig. 2.
                                                                                      • Where an external "Drip Loop" is not
                                                                                          possible, or if the wiring enters through the
                                                                                          upward facing (top) surface of the box, then
                                                                                          an internal "Drip Loop" is recommended; see
                   Fig. 2        Acceptable terminal box positions
                                                                                          fig. 3.
              4.3 Electrical connection

                                                                                                                               Green
                                                                                                                               White
                                                                                                                                         Black
                            Warning!
                            Risk of electrical shock!
                            The electrical connection and
                            protection should be carried out in
                            accordance with the latest edition
                            of the National Electrical Code,
                            local codes and regulations by a
                                                                                                                                SWITCH
                                                                                                                                SPEED

                            qualified electrician.
                            The safe operation of this pump
                            requires that it be grounded in
                            accordance with the National                                                     CAPACITOR
                            Electrical Code and any state, local
                            governing codes and
                            regulations.
                            Ground wires should be copper
                                                                                                     Green
                                                                                                             White
                                                                                                             Black

                            conductors of at least the size of
                            the circuit conductor supplying
                            power to the pump. Connect the
                            ground wire to the grounding point                                                           CAPACITOR
                            in the terminal box and then to an
                            acceptable ground. Do not ground
                            to gas or water supply line.
                            All wire sizes should be copper and
                            size-based on the ampacity
                                                                                                                                                 TM04 5634 3609

                            (current carrying properties of a
                            conductor) as required by the
                            National Electrical Code or local
                            regulations. Additionally UL
                            requires the following wire sizes to
                            be used: 18-12 Solid or 14-12
                            Stranded.
                            Both the power and grounding                                Fig. 3    Examples of ground and power
                            wires must be suitable for at least                                   supply connections (115V and
                            194 °F (90 °C).                                                       108-230 V) with internal drip loop

              6
4.4 Insulation shell

                                                                                                                                       (QJOLVK 86
For pumps with provided insulation shell, the                          Do not block
                                                                       weep slots
following procedures are required to insure safe
and proper installation.
1. Pump and mating piping flange bolts need to
    be installed towards the pump as illustrated
    in fig. 4.
2. Apply water proof, heat resistant, silicon
    based sealant to insulation shell. Care
    should be taken to not block weep slots for
    pump motor when applying sealant. Failure
    to follow proper sealant location procedures
    could damage motor and insulation shell.
    See fig. 5 for proper locations when applying                                          Do not block
    sealant.                                                                               weep slots
3. Mate the two insulation shells over the pump
    volute as illustrated in fig. 6. If the shells do
    not mate; flange bolts are installed in the
    wrong direction, review step one and or
    switch mating shell location.

                                                                                                                      TM05 1889 3811
4. Proper amount of time should be allowed for
    sealant to set-up before any additional
    installation work is performed. See sealant
    manufactures recommended time for sealant
    set-up. See fig. 7 for final configuration.

           Insert flange bolts                                      Fig. 5    Applying silicon sealant (dotted
           toward pump                                                        areas indicate sealant)

                                                                                                                      TM05 1890 3811
                                                   TM05 1888 3811

                                                                    Fig. 6    Insulation shell installation (dotted
       Insert flange bolts                                                    areas indicate sealant)
       toward pump

  Fig. 4     Connect pump to piping, installing
             flange bolts toward the pump
                                                                                                                      TM05 1891 3811

                                                                    Fig. 7    Ready for insulation wrap

                                                                                                                          7
5. Starting the pump
(QJOLVK 86

              5.1 Vent the piping system
              After the pump has been installed and the
              electrical connections made, the piping system
              must be vented.

                                                                                                                                   TM04 5641 3609
                            Caution!
                            Never operate the pump dry — the
                            system must first be filled with
                            liquid and vented.
                  &DXWLRQ

              NOTE: Do not vent the piping system through                           Fig. 9     Terminal box cover/lid with speed
              the pump. Instead, follow these steps:                                           switch in medium speed (Speed 2)
              1. Fill and pressurize the system with liquid,
                  and vent all trapped air from the piping by                     Switch position       Speed in % of max. speed
                  suitable means.
                                                                                  Low (Speed 1)               approx. 60 %
              2. If any isolation valves are used, make sure
                  they are OPEN.                                                  Medium (Speed 2)            approx. 80 %
                                                                                  High (Speed 3)                 100%
                            Warning!
                            If the vent screw/plug is to be                       Changing to lower speeds offers considerable
                            loosened, care should be taken                        reduction in energy consumption and less noise
                            to ensure that the escaping                           in the system.
                            scalding hot liquid does not cause
                            personal injury or damage to                                 Low            Medium         High
                            components.                                             H               H            H

                                                                                                                                   TM04 5640 3609
              3. Vent the pump by removing the vent plug.
                 When water exists through the port, the
                 pump is fully vented / primed.
              4. Reinstall the vent plug.                                                       Q            Q                Q
                                                                                               H = Head and Q = Flow

                                                                                    Fig. 10    Pump performance at speed
                                           Inspection screw/                                   settings
                                           vent plug
                                                                 TM04 5644 3609

                  Fig. 8      Vent screw/plug removal for pump
                              venting

              5.2 Speed selection
              UPS models
              Speeds can be changed via the speed switch on
              the terminal box cover. Power must be turned off
              before changing speeds. The speed in the three
              positions appears in the following table; also see
              fig. 10.
              UP models
              Speed is fixed on Speed 3 (High) and cover
              does not have a switch (cover is solid).

              8
6. Troubleshooting

                                                                                                                   (QJOLVK 86
6.1 Fault finding chart

          Warning!
          Before removing the terminal box cover, make sure that the electrical supply has
          been switched off and that it cannot be accidentally switched on.
          The pumped liquid may be scalding hot and under high pressure. Before any
          removal or dismantling of the pump, the system must be drained or the isolation
          valves on both sides of the pump must be closed.

Fault                         Cause                           Remedy

1.   The pump does not        a)   External circuit breaker   Switch the circuit breaker on.
     run. None of the              is switched off.
     indicator lights are
                              b)   Current-/voltage-          Repair the insulation defects and reset
     on.
                                   operated ground fault      the interrupter.
                                   interrupter has tripped.
2.   The pump does not        a)   Rotor is blocked.          Switch off the electrical supply and clean
     run. The green                                           /repair the pump.
     indicator light is on.
                              b)   The speed switch is not    Switch off the electrical supply at the
                                   fully positioned (is       external circuit breaker and change speed
                                   between speeds)            switch into position.
                              c)   The pump has been cut      Check that the liquid temperature falls
                                   out by the thermal         within the specified range. The pump will
                                   overload switch due to     restart automatically when it has cooled to
                                   high liquid temperature.   normal temperature.
3.   Noise in the system.     a)   Air in the system.         Vent the system.
     The green indicator
                              b)   The pump flow is too       Reduce the pump performance.
     light is on.
                                   high.
                              c)   The pressure is too        Reduce the pump performance.
                                   high.
4.   Noise in the pump.       a)   Air in the pump.           Vent the pump.
     The green indicator
                              b)   The inlet pressure is      Increase the inlet pressure and/or check
     light is on.
                                   too low.                   the air volume in the expansion tank
                                                              (if installed).
5.   The pump runs, but       a)   The LED diode was          Switch off the power and change the
     the indicator light is        damaged when               printed circuit board or replace the
     off.                          installing the terminal    complete terminal box.
                                   box cover or is burned
                                   out.
6.   Insufficient heat in     a)   The pump performance       Increase the pump performance, if
     some places in the            is too low.                possible. Flow too fast through the
     heating system.                                          boiler/heat exchanger may not allow for
                                                              the proper BTU transfer to the fluid. If fluid
                                                              is too slow, fluid may be cooling too much
                                                              before returning from the system. If
                              b)   The performance is too
                                                              changing speeds does not resolve the
                                   high.
                                                              problem, replacing the pump with a
                                                              properly sized pump may be required.

                                                                                                               9
6.2 Preliminary checks
(QJOLVK 86

              Supply voltage
              To check the voltage being supplied to the
              motor, use a voltmeter.

                             Warning!
                             Be careful, since power is still

                                                                                                                                 TM04 5639 3609
                             being supplied to the pump. Do not
                             touch the voltmeter leads together
                             while they are in contact with the
                             power lines.
              Single-phase motors
              Touch one voltmeter lead to each of the lines
                                                                                   Fig. 12   Current measurement
              supplying power to the pump as shown in
              fig. 11:                                                           Evaluation
              • L and N for 115 V and 208-230V circuits                          If the current draw exceeds the listed nameplate
                   (L = L1 and N = L2 for 208 - 230V circuits                    amps, or if the current imbalance is greater than
                   in the U.S.)                                                  5 % between each leg, then check the following:
              These tests should give a reading of full line                     • The voltage supplied to the pump may be too
              voltage.                                                                high or too low.
                                                                                 • The terminals/wires in the terminal box or to
                                                                                      circuit breaker may be loose.
                                                                                 • The contacts on the motor starter may be
                                                                                      burned.
                                                                                 • The terminals in the starter or terminal box
                                                                                      may be loose.
                                                                                 • There may be a winding defect. Check the
                                                                                      winding and insulation resistance; see
                                                                                      section 5.6 Resistance charts.
                                                                                 • The motor windings may be shorted or
                                                                                      grounded.
                                                                                 • The pump may be damaged in some way
                                                                TM04 5645 3609

                                                                                      and may be causing a motor overload.
                                                                                 • A voltage supply problem may exist.

                                                                                 6.4 Insulation resistance
                                                                                     (lead-to-ground)
                   Fig. 11     Testing with voltmeter                            To check the insulation resistance
                                                                                 (lead-to-ground) of the motor and leads, use a
              Evaluation                                                         megohmmeter and follow these steps:
              When the motor is under load, the voltage                          1. Turn the POWER OFF.
              should be within 10% (+ or –) of the nameplate
              voltage.                                                           2. Disconnect all electrical leads to the motor.
              Any variation larger than this may indicate a                      3. Set the scale selector on the megohm-
              poor electrical supply and can cause damage to                         meter to R x 100K, touch its leads together,
              the motor windings. The motor should not be                            and adjust the indicator to zero.
              operated under these conditions. Contact your                      4. Touch the leads of the megohmmeter
              power supplier to correct the problem or change                        individually to each of the motor leads and to
              the motor to one requiring the voltage you are                         ground (i.e. L to ground; N to ground, etc.).
              receiving.

              6.3 Current measurement
              To check the current using an ammeter, follow
              these steps:
                                                                                                                                  TM04 5638 3609

              1. Make sure the pump is operating.
              2. Set the ammeter to the proper scale.
              3. Place the tongs of the ammeter around the
                 leg to be measured.
              4. Compare the results with the amp draw
                 information on the motor nameplate.                               Fig. 13   Insulation resistance measurement
              5. Repeat for the other legs.

              10
Evaluation

                                                                                                                                      (QJOLVK 86
The resistance values for new motors must
exceed 1,000,000 ohms. If they do not, replace

                                                                                                                    TM04 5633 3609
power head.

6.5 Winding resistance (line-to-line)
To check the winding resistance of the motor
windings, use a megohmmeter and follow these
                                                                         L N
steps.
                                                        Fig. 14
1. Turn the POWER OFF.
2. Disconnect all electrical leads to the motor.      Checking at the pin connection behind the
                                                      terminal box (see section 6.3 Replacing the
3. Set the scale selector on the
                                                      terminal box or capacitor for terminal box
   megohmmeter to R x 1, touch its leads
                                                      removal):
   together and adjust the indicator to zero.
4. Using the charts in section 5.6 for                       Stator
   reference, touch the leads of the                                                  Winding groups
                                                        pin connection
   megohmmeter to the appropriate pair of
   connectors. Check all pairs that are present             1 to 2                    RA: Main winding
   and write down and label (RA 1, RS1, RS2) all            4 to 5                  RS1: Auxiliary winding
   readings.
                                                            6 to 7                  RS2: Auxiliary winding
    – In T-box at L & N: UP will = Speed 3/High
                                                            2 to 8                        T: Thermiks
    – In T-box at L & N: UPS value depends on
       the selected speed (Speed 1, 2, or 3)
    – For both UP and UPS: with the terminal                                              OHM value      Nomin
       box removed, check all combinations RA,                Connection
                                                                                            range          al
       S1, S2
5. Compare your readings to the matching                             RA (1 to 2)     =    6.7 to 7.9         7.3
   model, phase and voltage listed in the charts                  RS1 (4 to 5)       =    3.0 to 3.6         3.3
   in section 5.6.                                     115V
                                                                  RS2 (6 to 7)            3.0 to 3.6         3.3
Evaluation                                                           T (2 to 8)      =        0
The resistance values must fall within the
tolerances listed in section 5.6. If they do not,
replace the power head.                                                                   OHM value      Nomin
                                                              Connection
                                                                                            range          al
6.6 Resistance charts
                                                                     RA (1 to 2)      = 30.4 to 35.6         33
Checking connections in the terminal box at the        208V
power connections L and N; see fig. 14 for 115 V                     RS1 (4 to 5)     = 12.0 to 14.0         13
                                                         -
and 208 - 230 V.                                       230V          RS2 (6 to 7)     = 12.0 to 14.0         13
                                                                      T (2 to 8)      =        0
                                OHM value
        Connection                          Nominal
                                  range
                                                      Fig. 15 shows terminal plug-in stator relationship
                                  6.9 to              to the top / nameplate end of the stator.
         L to N (Speed 3)   =                7.55
                                   8.01
                                                                                                                   TM04 5643 3609

                                  9.7 to
 115V    L to N (Speed 2)   =                10.54
                                  11.38
                                 12.97 to
         L to N (Speed 1)   =                14.10
                                  15.23

        Connection
                                OHM value
                                            Nominal
                                                        Fig. 15       Terminal plug in stator
                                  range

                                 34.63 to
         L to N (Speed 3)   =                37.65
                                  40.66
 208V
                                 41.57 to
   -     L to N (Speed 2)   =                45.19
                                  48.81
 230V
                                                                                                                     TM04 5637 3609

                                 56.67 to
         L to N (Speed 1)   =                61.60
                                  66.53

*T can only be checked with the terminal box
removed; if the thermiks is open the pump will
not run.
                                                        Fig. 16       Internal wiring

                                                                                                                   11
7. Replacing components                                        7.2 Fitting the pump head
(QJOLVK 86

                                                                             1. Carefully remove the new pump head
                             Warning!                                            assembly from its packaging. Separate the
                                                                                 impeller/rotor assembly from the new pump
                             Before starting any work on this                    head.
                             circulator, make sure electrical
                             supply has been switched off and                2. While holding the thrust bearing plate,
                             that it cannot be accidentally                      carefully place the impeller/rotor assembly
                             switched on.                                        into the pump housing. The bearing plate
                                                                                 should fit snugly into the lowest machined
                                                                                 surface in the pump housing.
              7.1 Removing the pump head
                                                                             3. Ensure that the impeller/rotor assembly can
              1. Disconnect or TURN OFF the power                                rotate freely.
                 supply.
                                                                             4. Place the O-ring over the rotor and locate it
              2. Close any isolation valves on either side of                    into the inner diameter of the pump
                 the pump to avoid draining the system of                        housing.
                 liquid.
                                                                             5. Carefully place the pump head housing over
              3. Remove the vent plug to relieve any                             the rotor and rotate it so the terminal box is
                 system pressure retained in the pump.                           in the position you wish; see section
                 Exercise caution as the fluid may be                            4.2.1 Rotating the terminal box.
                 scalding hot and under pressure. Only
                 after the pressure has been relieved and the                6. Ensure that the pump head housing is
                 pump drained should you proceed with the                        properly seated on the pump housing. Do
                 next steps.                                                     not force the two together — if there is
                                                                                 binding, disassemble them and repeat steps
              4. Disconnect the electrical leads from the                        2 to 6. Cross-tighten the allen-head screws
                 terminal box.                                                   evenly.
              5. Disconnect and remove the conduit from the                      Torque to: 7 ft lb / 9.5 Nm.
                 terminal box.                                               7. Check to make sure the rotor turns freely. Do
              6. Loosen and remove the four 5 mm                                 this by removing the vent plug in the middle
                 allen-head screws which connect the pump                        of the pump nameplate. Insert a
                 head housing to the pump housing.                               medium-size, flat-blade screwdriver into the
              7. Remove the pump head from the pump                              slot at the exposed end of the shaft. Gently
                 housing. Exercise care as the rotor may                         turn the shaft. If it does not turn easily,
                 fall out of the stator or pump housing.                         repeat steps 1 through 6 above.
              8. Clean the machined surfaces in the pump                         If the rotor spins freely, proceed to step 8. Do
                 housing of any foreign material.                                not put the vent plug back into the pump until
                                                                                 the end of step 10.
                                                                             8. The position of the nameplate can be
                                                                                 changed by easing the outer edge of the
                                                                                 plate at the cutout with a screwdriver. Turn
                                                                                 the nameplate to the required position and
                                                                                 push into place.
                                                                             9. Follow electrical instructions in section
                                                                                 3.3 Electrical connection.
                                                                             10. Refill the system, open the isolation valves
                                                                                 and vent the system. Also allow air to vent
                                                                                 out of the pump, once water flows out the
                                                                                 vent hole, replace the vent plug removed in
                                                                                 step 7. See additional instructions in
                                                                                 section 4.1 Vent the piping system.

                                                          Terminal box       Bearing plate     Impeller

                                                                    O-ring

                    Allen
                                                                                                                               TM04 5642 3609

                    screws
                    (4) 5 mm

                                                                                Thrust bearing
                               Pump head/stator housing        Rotor assembly            Pump housing

                   Fig. 17     Removing and fitting the pump head

              12
7.3 Replacing the terminal box

                                                                                                                                               (QJOLVK 86
                                                                                         Terminal box
    or capacitor                                                                         holding screws
          Warning!
          Before starting any work on this
          circulator, make sure electrical
          supply has been switched off and

                                                                                                                              TM04 5642 3609
          that it cannot be accidentally
          switched on.

Removal
1. Before replacing the terminal box and
   capacitor, make sure the power is OFF.
                                                                  Fig. 19       Terminal box holding screws
2. Remove the terminal box cover / lid by
   completely loosening the Phillips head screw
   in the center of the cover / lid.                            8. Additional technical data
3. Disconnect all wiring. Move the capacitor to                                            1x115V +/-10 %, 60Hz
   allow access to the screws.                                  Supply voltage:
                                                                                           1 x 208 - 230V +/-10 %, 60Hz
4. Remove the two T15 Torx head screws                          Motor protection:          Thermally protected
   holding the terminal box in place.
                                                                Enclosure class:           CSA Type 2
5. Pull firmly and evenly on both sides of the                  Insulation class:          H
   terminal box to free it from the stator / pump
                                                                Max. discharge
   head.                                                        press.:
                                                                                           145 psi (10 bar)

Installation                                                    Max. sound press.
                                                                                           30 dB(A)
1. Carefully press the terminal box into the                    level:
    stator socket.                                              Water hardness:            14 dH
2. Replace the two T15 Torx head screws and
    torque to 1.5 ft.-lbs / 2 Nm.                                                    Open systems
3. Replace the wiring (refer to section                                       (domestic, potable hot water):
    3.3 Electrical connection).                                                             Fluid              Ambient
4. Use care when installing the terminal box
                                                                Min.                  36 °F (2 °C)         33 °F (1 °C)
    cover with speed switch (rough handling
    can damage the run light LED on the                         Max.                  < 149 °F (65 °C)     100 °F (38°C)
    printed circuit board (PCB)). Next insert
    the Phillips head screw through the cover
    and tighten to a snug fit.
                                                                              Caution!
10. Restore power.
                                                                              In domestic hot-water systems,
                                                                              it is recommended to keep the
                                                                              liquid temperature below +149 °F
                                                                  &DXWLRQ     (+65 °C) to eliminate the risk of lime
                                                                              precipitation.

                                                                                 Closed systems
                                                                   (non-potable heating or cooling airless fluid):

                                                                             Pump
                                               TM04 5641 3609

                                                                                                Fluid           Ambient
                                                                             models

                                                                Min.           All          36 °F (2 °C)       33 °F (1 °C)

                                                                        UPS 26-150         230 °F (110 °C)    100 °F (38°C)

                                                                Max.    UPS 43-100         230 °F (110 °C)    100 °F (38°C)
  Fig. 18   Terminal box lid / cover                                        UPS 50-60      212 °F (100 °C)    100 °F (38°C)

                                                                                     Water and glycol mix:
                                                                Max.       50 % glycol @ 15 °F (-9.5 °C) fluid
                                                                (Hydraulic performance change can be expected.)

                                                                9. Disposal
                                                                This product or part of it must be disposed of in
                                                                an environmentally sound way; please use the
                                                                public or private waste collection servic

                                                                                                                           13
Français (CA) Notice d'installation et de fonctionnement
)UDQ©DLV &$

               Installation d'origine et notice d'utilisation.        l'enlèvement, à l'installation ou au transport, ou
                                                                      de toute autre dépense relative à une demande
               TABLE DES MATIÈRES                                     au titre de la garantie. Les produits vendus par
                                                                      Grundfos mais qui ne sont pas fabriqués par ce
                                                             Page     dernier sont soumis à la garantie proposée par
                1.    Garantie limitée                         14     le fabricant et ne sont pas couverts par la
                2.    Avertissement de sécurité                 14    garantie de Grundfos. Grundfos ne sera pas
                2.1   Lire le présent livret                    14    tenu responsable des dégâts ou de l'usure des
                                                                      produits causés par une utilisation anormale, un
                2.2   Travaux électriques                       15
                                                                      accident, un abus, un mauvais emploi, une
                3.    Liste de vérification avant                     modification ou une réparation non autorisée, ou
                      installation                              15    si le produit n'a pas été installé conformément
                3.1   Confirmer qu'il s'agit de la bonne              aux instructions d'installation et d'utilisation de
                      pompe                                     15    Grundfos.
                3.2   Vérifier l'état de la pompe               15    Pour obtenir un service au titre de la présente
                3.3   Vérifier l'alimentation                   15    garantie, le produit défectueux doit être renvoyé
                3.4   Exigences quant au liquide pompé          15    au distributeur ou au détaillant des produits
                                                                      Grundfos auprès duquel il a été acheté, et il doit
                4.    Procédures d'installation                 16    être accompagné d'une preuve d'achat et de la
                4.1   Considérations relatives aux                    date de l'installation et de la défaillance, ainsi
                      canalisations                             16    que des pièces justificatives relatives à
                4.2   Modification de la position de la               l'installation. Sauf indication contraire, le
                      boîte à bornes                            17    distributeur ou le détaillant entrera en contact
                4.3   Raccordement électrique                   18    avec Grundfos ou avec un centre de service
                4.4   Insulation coquille                       19    autorisé pour connaître la marche à suivre. Tout
                                                                      produit défectueux doit être renvoyé fret payé
                5.    Démarrage de la pompe                     20    d'avance à Grundfos ou à un centre de service;
                5.1   Aération du système de                          les documents justifiant la demande au titre de
                      canalisations                             20    la garantie et l'autorisation de renvoi du produit
                5.2   Réglage de la vitesse                     21    doivent être inclus suivant les instructions.
                6.    Dépannage                                 22    GRUNDFOS NE SERA PAS TENU
                6.1   Tableau indicateur de défaillances        22    RESPONSABLE DES DOMMAGES ACCES-
                6.2   Vérifications préliminaires               23    SOIRES OU CONSÉCUTIFS, DES PERTES OU
                                                                      DES DÉPENSES DÉCOULANT DE
                6.3   Mesure du courant                         23
                                                                      L'INSTALLATION OU DE L'UTILISATION DU
                6.4   Résistance d'isolement (entre                   PRODUIT OU DE TOUTE AUTRE CAUSE.
                      conducteur et terre)                      24    AUCUNE GARANTIE EXPRESSE OU
                6.5   Résistance à l'enroulement (phase à             IMPLICITE, Y COMPRIS LES GARANTIES DE
                      phase)                                    24    QUALITÉ MARCHANDE OU D'ADAPTATION À
                6.6   Tableaux des résistances                  24    UN USAGE PARTICULIER, N'EST FORMULÉE
                7.    Remplacement des composants               25    AU-DELÀ DES GARANTIES DÉCRITES OU
                                                                      MENTIONNÉES CI-DESSUS.
                7.1   Retrait de la tête de pompe               25
                7.2   Ajustement de la tête de pompe            25    Certaines juridictions n'autorisent pas les
                                                                      exclusions ou les limitations des dommages
                7.3   Réinstallation de la boîte à bornes
                                                                      accessoires ou consécutifs, et d'autres
                      ou du condensateur                        26    juridictions ne permettent pas de limitations
                8.    Données techniques                              relatives à la durée des garanties implicites. Par
                      supplémentaires                           27    conséquent, il se peut que les limitations ou les
                9.    Élimination                               27    exclusions ci-dessus ne s'appliquent pas à votre
                                                                      cas. La présente garantie vous accorde des
                                                                      droits spécifiques, et il se peut que vous ayez
               1. Garantie limitée                                    d'autres droits pouvant varier d'une juridiction à
               Les produits fabriqués par GRUNDFOS PUMPS              l'autre.
               CORPORATION (Grundfos) sont garantis à
               l'acheteur initial contre tous défauts de              2. Avertissement de sécurité
               matériaux et vices de fabrication pendant une
               période de 36 mois à compter de la date de
                                                                      2.1 Lire le présent livret
               fabrication. La responsabilité de Grundfos au
               titre de la présente garantie est limitée à la répa-   Le présent livret est conçu pour aider
               ration ou au remplacement de tout produit fabri-       l'installateur agréé à effectuer l'installation, à
               qué par Grundfos, à la discrétion de ce dernier,       amorcer le fonctionnement et à détecter les
               sans frais, port payé de l'usine de Grundfos ou        défaillances des pompes Small UP et UPS de
               d'un centre de service autorisé. Grundfos ne           Grundfos.
               sera pas tenu responsable des frais associés à

               14
Le respect des consignes figurant aux présentes      Autres considérations relatives aux pompes

                                                                                                         )UDQ©DLV &$
assurera un fonctionnement sécuritaire et sans       Small UP et UPS de Grundfos:
problème.                                            • Ces pompes sont conçues pour une
Le présent livret doit être confié au propriétaire      utilisation à l'intérieur uniquement.
de la pompe pour consultation ultérieure et          • Si elle est installée à l'extérieur, la pompe
comme source de renseignements au sujet du              doit être protégée par une enceinte
fonctionnement de la pompe. Le propriétaire qui         appropriée, bien aérée et étanche pour la
éprouve des problèmes concernant sa pompe               mettre à l'abri de l'humidité et de la saleté.
doit contacter un professionnel agréé.
                                                     • La température ambiante ne doit jamais
                                                        descendre sous la barre de 1 °C (33 °F).
2.2 Travaux électriques
                                                     • Pour connaître les exigences concernant les
Tous les travaux électriques doivent être               températures ambiantes et des liquides,
effectués par un électricien qualifié                   consultez les sections 2.4 Exigences quant
conformément à la plus récente édition du Code          au liquide pompé et 7 Données techniques
national de l'électricité et aux codes et               supplémentaires.
règlements locaux.
                                                     3.2 Vérifier l'état de la pompe
           Avertissement!                            Le carton d'expédition de la pompe est
           La défaillance du moteur ou du            spécialement conçu autour de la pompe en
           câblage peut causer un choc               cours de production afin d'éviter les dommages.
           électrique pouvant être fatal, que        Par mesure de précaution, la pompe doit rester
           ce soit par contact direct ou par         dans son carton jusqu'à ce que vous soyez prêt
           l'entremise d'eau stagnante. Pour         à l'installer. À ce moment, examinez la pompe
           cette raison, une mise à la terre         afin de détecter tout dommage pouvant découler
           appropriée de la pompe à la borne         de l'expédition.
           de terre de l'alimentation électrique
           est requise pour assurer une              Examinez également toutes les autres pièces
           installation et un fonctionnement         comprises dans l'envoi à l'affût de dommages
           sécuritaires.                             visibles. Après avoir enlevé la pompe de sa
                                                     boîte, soyez prudent afin d'ÉVITER de
           Dans le cadre de toutes les               l'échapper ou de la manipuler de manière
           installations, la tuyauterie en métal     inadéquate.
           hors terre doit être raccordée à la
           mise à la terre de l'alimentation, tel    Contenu de la boîte:
           que cela est stipulé dans le Code         • une pompe
           national de l'électricité. Tous les       • deux joints d'étanchéité (unités à collerette
           éléments de câblage doivent                 uniquement)
           respecter le Code national de
           l'électricité, ainsi que les règle-       • Un manuel d'installation et de
           ments locaux.                               fonctionnement.

                                                     3.3 Vérifier l'alimentation
3. Liste de vérification avant
                                                     Vérifiez l'alimentation électrique pour vous
   installation                                      assurer que la tension, la phase et la fréquence
                                                     correspondent à celles du moteur de la pompe.
3.1 Confirmer qu'il s'agit de la bonne               La tension de fonctionnement appropriée et
    pompe                                            d'autres renseignements de nature électrique
                                                     sont disponibles sur la plaque signalétique de la
•   Lisez la plaque signalétique de la pompe         pompe.
    pour vous assurer qu'il s'agit bien de celle
    que vous avez commandée.                         Le moteur de cette pompe est conçu pour
                                                     fonctionner à +/- 10 % de la tension nominale
•   Comparez les données de la plaque                indiquée sur la plaque signalétique.
    signalétique et la courbe de rendement de la
    pompe (pour la hauteur d'élévation, les m 3/h,   3.4 Exigences quant au liquide pompé
    etc.) aux caractéristiques de l'application
    pour laquelle vous prévoyez de l'installer.                Avertissement!
•   La pompe sera-t-elle à la hauteur de vos                   La pompe Small UP et UPS de
    attentes?                                                  Grundfos est uniquement conçue
3.1.1 Recommandations de pompe                                 pour fonctionner avec de l'eau. La
      relativement aux types de systèmes                       pompe ne doit pas être utilisée
                                                               pour transférer des liquides inflam-
• Systèmes ouverts (d'eau potable): volute
                                                               mables tels que le carburant diesel,
    (boîtier de pompe) en acier inoxydable ou en
                                                               l'essence et les liquides similaires.
    bronze uniquement.
                                                               La pompe n'est pas destinée à une
• Systèmes fermés (par ex., sans air, pour
                                                               utilisation dans une piscine ou en
    eau non potable): volute (boîtier de pompe)
                                                               milieu marin.
    en fonte, en acier inoxydable ou en bronze.

                                                                                                    15
La pompe peut faire circuler:
)UDQ©DLV &$

                                                                                   UPS 26-150         110 °C
               • De l'eau potable chaude.                                          UPS 43-100        (230 °F)     38 °C (100 °F)
                                                                           Max.
               • De l'eau contenant du glycol pour le chauf-                        UPS 50-60
                                                                                                      100 °C
                   fage à eau chaude (pour connaître les autres                                      (212 °F)
                   limitations, reportez-vous à la section 7.
                   Données techniques supplémentaires).                                   Mélange eau-glycol :
               • De l'eau de refroidissement.                              Max.     Liquide 50 % glycol à -9.5 °C (15 °F)
               Pour les systèmes d'eau chaude domestiques,                 (Des changements de la performance hydraulique peu-
               nous vous conseillons d'opter pour les versions             vent se produire.)
               avec boîtier de pompe en acier inoxydable.
               Tous les types de pompe (boîtier de pompe en
               acier inoxydable, en bronze ou en fonte) ne
                                                                           4. Procédures d'installation
               doivent pas être utilisés avec de l'eau dont le
               degré de dureté est inférieur à 14 grains par                             Avertissement!
               gallon de dureté.                                                         Ne faites jamais de
               Les liquides doivent être propres et exempts de                           raccordement dans la boîte à
               particules solides, de fibres ou d'huiles                                 bornes de la pompe sans tout
               minérales.                                                                d'abord couper l'alimentation
               Si la pompe est installée dans un système de                              électrique.
               chauffage, l'eau doit être conforme aux                                   La pompe ne doit pas être
               exigences des normes admises concernant la                                raccordée au système
               qualité de l'eau des systèmes de chauffage. Le                            électrique avant d'être installée
               liquide doit être exempt de particules solides, de                        correctement sur le système de
               fibres ou d'huiles minérales.                                             canalisations.
               La pompe est lubrifiée et refroidie par le liquide                      Mise en garde: risque de choc
               pompé. Par conséquent, le liquide pompé doit                            électrique - Cette pompe n'a
               toujours pouvoir circuler dans la pompe.                     3U«FDXWLRQ pas été testée pour une
               Les périodes prolongées sans circulation                                utilisation dans une piscine ou
               entraîneront l'usure prématurée des roulements                          en milieu marin.
               et une température excessive du moteur.
               Le liquide pompé doit satisfaire aux exigences              4.1 Considérations relatives aux
               de température indiquées dans les tableaux                      canalisations
               suivants.                                                   Lorsque vous procédez au raccordement aux
               Remarque: le liquide ne doit jamais geler                   canalisations, assurez-vous de suivre les
               pendant les périodes de non-fonctionne-                     recommandations du fabricant des canalisations
               ment.                                                       et de respecter toutes les exigences des codes
                                                                           relatifs aux matériaux de canalisation.
                                 Systèmes ouverts                          Nettoyez et rincez à fond toutes les saletés et
                        (domestiques, d'eau chaude potable):
                                                                           les sédiments présents dans le système avant
                                                          Température      d'amorcer l'installation de la pompe.
                                       Liquide
                                                           ambiante
                                                                           4.1.1 Emplacement sur la canalisation
               Min.              2 °C (36 °F)           1 °C (33 °F)       La pompe ne doit jamais être située au point le
               Max.              < 65 °C (149 °F)       38 °C (100 °F)
                                                                           plus bas du système de canalisations (là où la
                                                                           saleté et les sédiments s'accumulent), ni être
                                                                           située au point le plus élevé (là où l'air
                                                                           s'accumule).
                            Dans les systèmes de distribution
                            d'eau chaude domestique, il est
                            recommandé de maintenir la tempé-                       Avertissement!
                            rature du liquide sous la barre des                     La pompe doit être positionnée de
                            65 °C (149 °F) afin d'éviter le risque                  manière à ce que personne ne
               3U«FDXWLRQ
                            de précipitation de chaux.                              puisse accidentellement entrer en
                                                                                    contact avec ses surfaces
                                   Systèmes fermés                                  chaudes.
                      (liquide sans air non potable de chauffage           Dans le cadre de l'installation de la pompe dans
                                ou de refroidissement) :
                                                                           le système de canalisations, Grundfos vous
                        Modèles de la                      Température     recommande d'installer des manomètres dans
                                           Liquide
                          pompe                             ambiante       les brides ou les canalisations d'entrée et
                            Tous les
                                                                           d'évacuation. Cela permettra la vérification du
               Min.                      2 °C (36 °F)       1 °C (33 °F)   rendement de la pompe et du système.
                            modèles
                                                                           Ne bloquez pas les bouchons des canalisations
                                                                           dans les brides du boîtier de la pompe en
                                                                           installant la boîte à bornes au-dessus de
                                                                           ceux-ci.

               16
4.1.2 Positions de montage                                         Vous pouvez passer aux étapes suivantes

                                                                                                                        )UDQ©DLV &$
Les flèches figurant sur le boîtier de la pompe                    uniquement après avoir relâché la pression et
indiquent la direction d'écoulement de l'eau. La                   drainé la pompe.
pompe Small UP et UPS de Grundfos peut être                        4.2.1 Rotation de la boîte à bornes
installée sur des canalisations verticales ou
horizontales. En revanche, l'arbre moteur doit                     Pour changer la position de la boîte à bornes,
toujours demeurer à l'horizontale, tel qu'illustré                 suivez les étapes suivantes :
dans le schéma 1.                                                  1. Enlevez les quatre vis Allen (5 mm) qui
                                                                       relient la tête de pompe au boîtier de pompe.
                                                                   2. Soulevez/glissez soigneusement la tête de
                                                                       pompe du boîtier de pompe. Tournez ensuite
                                                                       la tête de pompe, et mettez la boîte à bornes
                                                                       dans la position désirée. La boîte à bornes
                                                                       peut être tournée par tranches de 90 º.
                                                                       Consultez les schémas 1 et 2 pour connaître
                                                                       les positions possibles et acceptables.
                                                                       N'INSTALLEZ PAS la boîte à bornes sous la
                                                                       pompe.

                                                                                Mise en garde! Soyez prudent:
                                                                                l'assemblage du rotor peut
                                                                                tomber de la tête ou du boîtier de la
                                                                                pompe si la pompe est tirée à une
                                                                   3U«FDXWLRQ   distance trop importante du boîtier.
                                                  TM04 5646 3609

                                                                   3. Assurez-vous que le joint torique est bien
                                                                       placé dans le boîtier de la pompe.
                                                                   4. Remettez la tête de pompe sur son boîtier.
                                                                   5. Serrez les vis Allen de 5 mm de manière
                                                                       diagonale et uniforme.
                                                                       Serrez-les au couple 7 pi/lb (9.5 Nm)
  Fig. 1       Positions d'installation                            6. Vérifiez que le rotor tourne librement. Pour
                                                                       ce faire, enlevez le bouchon d'aération situé
4.1.3 Position de la boîte à bornes
                                                                       au milieu de la plaque signalétique de la
À la base du stator, dans la partie la plus proche                     pompe. Insérez un tournevis à lame plate de
du boîtier de la pompe, se trouvent trois orifices                     taille moyenne dans la fente située sur
de drainage permettant l'évacuation de l'eau de                        l'extrémité exposée de l'arbre. Faites
condensation.                                                          doucement tourner l'arbre. S'il ne tourne pas
Ces orifices ne doivent pas être bloqués, qu'elle                      facilement, refaites les étapes 1 à 5
qu'en soit la raison, et l'un d'eux doit toujours                      ci-dessus. Si le rotor tourne librement,
être orienté vers le bas.                                              passez à l'étape 7. Ne remettez pas le
Il n'existe pas d'orifice de drainage directement                      bouchon d'aération sur la pompe avant la fin
sous la boîte à bornes. Cette dernière doit donc                       de l'étape 9.
être installée dans l'une des positions illustrées                 7. La position de la plaque signalétique peut
dans le schéma 1 ou 2.                                                 être changée en soulevant le bord extérieur
                                                                       de la plaque à niveau de l'entaille au moyen
4.2 Modification de la position de la                                  d'un tournevis. Faites tourner la plaque
    boîte à bornes                                                     signalétique jusqu'à la position requise et
                                                                       poussez-la pour la mettre en place.
             Avertissement!                                        8. Suivez les consignes électriques de la
             Avant de commencer à travailler                           section 3.3 Connexion électrique.
             sur ce circulateur, assurez-vous
                                                                   9. Remplissez le système à nouveau, ouvrez
             que l'alimentation électrique est
                                                                       les vannes d'isolation et aérez le système.
             coupée et qu'elle ne peut pas être
                                                                       Laissez également l'air s'échapper de la
             rétablie par accident.
                                                                       pompe. Dès que l'eau s'échappe de l'orifice
Si la pompe est déjà installée dans le système,                        d'aération, remettez le bouchon d'aération
celui-ci doit être drainé, ou bien les vannes                          enlevé à l'étape 6. Reportez-vous à la
d'isolement des deux côtés de la pompe doivent                         section 4.1 Aération du système de
être fermées, et la pression doit être relâchée en                     canalisations, pour obtenir des consignes
enlevant le bouchon d'aération.                                        supplémentaires.
                                                                   10. Le schéma 2 montre des positions
             Soyez prudent lorsque vous                                acceptables de la boîte à bornes, ainsi que
             drainez le système ou enlevez le                          les boucles d'égouttement recommandées
             bouchon d'aération: le liquide                            (lignes tiretées) dans le faisceau de câbles
             contenu dans le système peut être                         électriques, en fonction du point d'entrée.
3U«FDXWLRQ   bouillant et sous haute pression.

                                                                                                                   17
4.3 Raccordement électrique
)UDQ©DLV &$

                La boîte box
                          à bornes
                                                                                         Avertissement!
                Terminal
                Position
                position A A                                                             Risque de choc électrique!
                                                                                         Le raccordement et la protection
                                                                                         électriques doivent être effectués
                                                                                         par un électricien qualifié,
                                                                                         conformément à la plus récente
                                                                                         édition du Code national de
                                                                                         l'électricité, ainsi que des codes et
                La boîte box
                 Terminal  à bornes                                                      règlements locaux.
                Position
                 position BB
                                                                                         L'usage sans risque de cette pompe
                                                                                         nécessite une mise à la terre
                                                                                         conforme au Code national de
                                                                                         l'électricité et aux codes et
                                                                                         règlements locaux et des États.
                                                                                         Les câbles de mise à la terre
                                                                                         doivent être des conducteurs en
                                                               TM04 5636 3609

                La boîte à   bornes                                                      cuivre ayant au moins le calibre du
                 Terminal  box
                Position
                 position CC
                                                                                         conducteur de circuit
                                                                                         alimentant la pompe en électricité.
                                                                                         Raccordez le fil de mise à la terre au
                                                                                         point de masse de la boîte à bornes,
                                                                                         puis à la mise à la terre appropriée.
                    Fig. 2   Positions acceptables de la boîte à                         N'effectuez pas la mise à la terre sur
                             bornes                                                      une canalisation d'alimentation en
                                                                                         eau ou en gaz.
                                                                                         Tous les câbles doivent être en
                                                                                         cuivre et leur calibre doit être en
                                                                                         fonction du courant admissible (les
                                                                                         propriétés de charge d'un
                                                                                         conducteur), tel que cela est requis
                                                                                         par le Code national de l'électricité
                                                                                         ou les règlements locaux. De plus,
                                                                                         l'UL requiert l'utilisation des câbles
                                                                                         de calibres suivants : fil massif de
                                                                                         calibre 18-12, ou fil multibrin de
                                                                                         calibre 14-12.
                                                                                         Tant les câbles d'alimentation que
                                                                                         ceux de mise à la terre doivent
                                                                                         pouvoir résister à une température
                                                                                         d'au moins 90 °C (194 °F).
                                                                                La tension de fonctionnement appropriée et
                                                                                d'autres renseignements de nature électrique
                                                                                sont indiqués sur la plaque signalétique de la
                                                                                pompe, qui est fixée à la partie supérieure du
                                                                                moteur.
                                                                                • Le moteur est protégé thermiquement pour
                                                                                    les trois vitesses, et aucune protection
                                                                                    externe supplémentaire n'est requise.
                                                                                • Reportez-vous au schéma 3 pour connaître
                                                                                    les emplacements appropriés du
                                                                                    raccordement de la mise à la terre et de
                                                                                    l'alimentation (115 V et 208-230 V).
                                                                                • Les bornes de raccordement comportent un
                                                                                    levier à pousser ou sont à bascule. Poussez
                                                                                    le levier vers le bas et insérez le câblage de
                                                                                    champ. Poussez le levier vers le bas, et tirez
                                                                                    les câbles pour les enlever.

               18
•   Ensuite, soyez minutieux lors de l'installation                       4.4 Insulation coquille

                                                                                                                                           )UDQ©DLV &$
    du couvercle de la boîte à bornes avec le
                                                                          Pour les pompes avec insulation coquille fourni,
    commutateur de vitesse (une manipulation
                                                                          les procédures suivantes sont nécessaires pour
    brusque peut endommager la DEL de
                                                                          assurer une installation sécuritaire et
    marche sur la carte de circuits imprimés).
                                                                          appropriée.
    Insérez la vis Phillips dans le couvercle, et
    serrez-la bien.                                                       1. Installer les boulons de pompe et boulons de
                                                                              tuyauteries vers la pompe comme illustré sur
•   Une "boucle d'égouttement" externe est
                                                                              la fig. 4.
    recommandée dans le faisceau de câbles
    électriques. Reportez-vous au schéma 2.                               2. Appliquez étanche, anti-calorique scellant à
                                                                              base de silicone sur insulation coquille.
•   Lorsqu'il est impossible de créer une "boucle
                                                                              Des précautions doivent être prises pour ne
    d'égouttement "externe, ou si le câblage
                                                                              pas obstruer trous d'pleures pour moteur de
    entre par la surface orientée vers le haut
                                                                              la pompe lors de l'application du scellant. Le
    (partie supérieure) de la boîte, une "boucle
                                                                              non respect de procédures appropriées de
    d'égouttement" interne est plutôt
                                                                              l'emplacement d'scellant pourrait endomma-
    recommandée. Reportez-vous au schéma 3.
                                                                              ger le moteur de la pompe et la insulation
                                                                              coquille. Voir fig. 5 pour les emplacements
                                                                              appropriés lors de l'application du scellant.
                                  Blanc
                                  Noir
                                  Vert
                                  Green
                                   White
                                   Black

                                                                              Faites correspondre les deux côtés de la
                                                                              insulation coquille au sur le volute de la
                                                                              pompe comme illustré sur la fig. 6.
                                                                          3. Correspondre deux côtés de insulation
                                                                              coquille autour de la volute de la pompe
                                                                              comme indiqué dans la fig. 6. Si les
                                                                              réservoirs ne s'accouplent pas, bride
                                   contrôle
                                   commutateur

                                                                              boulons sont installés dans la mauvaise
                                     SWITCH
                                     SPEED

                                                                              direction, relire la première étape et / ou
                                            de vitesse

                                                                              changez coquille d'accouplement.
                                                                          4. Bonne quantité de temps devrait être
                                                  de

                CAPACITOR                                                     autorisé pour le séchage de la scellant avant
                                                                              toute installation supplémentaire n'est
                                                                              effectué. Voir scellant fabrique temps
                                                                              recommandé pour le séchage de la scellant.
                                                                              Voir fig. 7 pour la configuration finale.
              Blanc
              Noir
              Vert
               Green
               White
                Black

                                                                                Insérer les boulons
                                                                                de bride vers la pompe
                            CAPACITOR
                                                         TM04 5634 3609

    Fig. 3   Exemples de connexions de mise
             à la terre et d'alimentation
             (115 V et 108-230 V) avec boucle
             d'égouttement interne
                                                                                                                          TM05 1888 3811

                                                                              Insérer les boulons
                                                                              de bride vers la pompe

                                                                            Fig. 4    Raccorder la pompe à la tuyauterie;
                                                                                      insérer les boulons de bride vers la
                                                                                      pompe

                                                                                                                          19
You can also read