UCB BIOSCIENCES 4000 Paramount Pkwy Suite 200 & 300 Morrisville, NC 27560 Gensler Architect 613 Hillsborough Street Raleigh, NC, 27603 Telephone 919.239.7828 MEP Engineer NC License #C-0914 150 Fayetteville Street Suite 250 Raleigh, NC 27601 Telephone 919.296.2200 Consultant Fire Protection 123 Street Address Suite XXX City, State, Zip Telephone XXX.XXX.XXX Facsimile XXX.XXX.XXXX Consultant AV Consultant 123 Street Address Suite XXX City, State, Zip Telephone XXX.XXX.XXX Facsimile XXX.XXX.XXXX DESIGN DEVELOPMENT REVISED PRICING JUNE 19, 2020
DRAWING INDEX BUILDING CODE SUMMARY BUILDING CODE SUMMARY BUILDING CODE SUMMARY UCB Sheet Revisions Number GENERAL Sheet Name Latest Description Date ENERGY SUMMARY FIRE PROTECTION REQUIREMENTS 2018 APPENDIX B BUILDING CODE SUMMARY FOR ALL COMMERCIAL PROJECTS BIOSCIENCES G0.00 COVER 3 DD REVISED PRICING 2020-06-19 ENERGY REQUIREMENTS: (EXCEPT 1 AND 2-FAMILY DWELLINGS AND TOWNHOUSES) 4000 Paramount Pkwy G0.02 APPENDIX B 3 DD REVISED PRICING 2020-06-19 (Reproduce the following data on the building plans sheet 1 or 2) The following data shall be considered minimum and any special attribute required to meet the energy code shall also be provided. Each Designer shall furnish the required portions of the project information for the Suite 200 & 300 G1.01 VICINITY & LOCATION MAPS, PROJECT INFO. & SCOPE, GRAPHIC SYMBOLS & ABBREVIATION 3 DD REVISED PRICING 2020-06-19 G2.02 EGRESS & OCCUPANCY PLAN - LEVEL 02 3 DD REVISED PRICING 2020-06-19 plan data sheet. If performance method, state the annual energy cost for the standard reference design vs FIRE RATING DESIGN # SHEET # SHEET # Morrisville, NC 27560 annual energy cost for the proposed design. SEPARATION DETAIL # FOR FOR FOR PROVIDED G2.03 EGRESS & OCCUPANCY PLAN - LEVEL 03 3 DD REVISED PRICING 2020-06-19 BUILDING ELEMENT DISTANCE REQ'D (W/___* AND RATED RATED RATED Name of Project: UCB BIOSCIENCE FITOUT Existing building envelope complies with code: No (FEET) SHEET # ASSEMBLY PENETRATION JOINTS G5.01 PARTITION TYPE DETAILS 3 DD REVISED PRICING 2020-06-19 REDUCTION) Address: UCB BIOSCIENCE FITOUT Zip Code: 27560 G6.01 DOOR ELEVATIONS AND DOOR SCHEDULE 3 DD REVISED PRICING 2020-06-19 Exempt Building: select one Provide code or statutory reference: Structural Frame,including columns, girders, trusses 0 HR. EXISTING EXISTING EXISTING EXISTING EXISTING Owner / Authorized Agent: - G6.02 DOOR, FRAME AND HARDWARE SCHEDULES 3 DD REVISED PRICING 2020-06-19 Climate zone: 4A Bearing Walls Phone # - E-Mail - G8.01 FINISH MATERIALS LEGEND 3 DD REVISED PRICING 2020-06-19 Method of Compliance: ASHRAE 90.1 Exterior G9.11 INTERIOR RENDERINGS AND AXONOMETRICS 3 DD REVISED PRICING 2020-06-19 (If "Other" specify source here) North 0 HR. EXISTING EXISTING EXISTING EXISTING EXISTING Owned By: X Privately City/County State THERMAL ENVELOPE (Prescriptive method only) East 0 HR. EXISTING EXISTING EXISTING EXISTING EXISTING Code Enforcement Jurisdiction: X City MORRISVILLE County WAKE State INTERIORS West 0 HR. EXISTING EXISTING EXISTING EXISTING EXISTING 613 Hillsborough St. Tel 919.239.7828 I1.102 CONSTRUCTION PLAN - LEVEL 02 3 DD REVISED PRICING 2020-06-19 Roof / Ceiling Assembly: (each assembly) South 0 HR. EXISTING EXISTING EXISTING EXISTING EXISTING Raleigh, NC 27603 Fax 919.239.7829 I1.103 CONSTRUCTION PLAN - LEVEL 03 3 DD REVISED PRICING 2020-06-19 United States Description of assembly: RIGID INSULATION ON METAL DECK CONTACT: I1.202 REFLECTED CEILING PLAN - LEVEL 02 3 DD REVISED PRICING 2020-06-19 Interior 0 HR. EXISTING EXISTING EXISTING EXISTING EXISTING I1.203 REFLECTED CEILING PLAN - LEVEL 03 3 DD REVISED PRICING 2020-06-19 Nonbearing Walls and DESIGNER FIRM NAME LICENSE # PHONE # E-MAIL Partitions I1.302 FINISH PLAN - LEVEL 02 3 DD REVISED PRICING 2020-06-19 Architectural: GENSLER CHAD PARKER 10105 919.239.7831 CHAD_PARKER@GENSLER.COM U-Value of total assembly: Exterior walls I1.303 FINISH PLAN - LEVEL 03 3 DD REVISED PRICING 2020-06-19 R-Value of insulation: 30 North >30' 0 HR. EXISTING EXISTING EXISTING EXISTING EXISTING Civil: N/A I1.402 FURNITURE PLAN - LEVEL 02 (FOR REFERENCE ONLY) 3 DD REVISED PRICING 2020-06-19 Skylights in each assembly: East >30' 0 HR. EXISTING EXISTING EXISTING EXISTING EXISTING Electrical: OPTIMA ENGINEERING AMANDA E. ANDRASSY 39108 919.926.2200 abrooks@optimaengineering.com U-Valye of skylight: I1.403 FURNITURE PLAN - LEVEL 03 (FOR REFERENCE ONLY) 3 DD REVISED PRICING 2020-06-19 West >30' 0 HR. EXISTING EXISTING EXISTING EXISTING EXISTING Fire Alarm: OPTIMA ENGINEERING AMANDA E. ANDRASSY 39108 919.926.2200 abrooks@optimaengineering.com total square footage of skylights in each assembly: I2.101 INTERIOR ELEVATIONS 3 DD REVISED PRICING 2020-06-19 South >30' Plumbing: OPTIMA ENGINEERING EVAN C. CONNELL 045488 919.926.2200 econnell@optimaengineering.com 0 HR. EXISTING EXISTING EXISTING EXISTING EXISTING I2.102 INTERIOR ELEVATIONS 3 DD REVISED PRICING 2020-06-19 Exterior Walls (each assembly) OPTIMA ENGINEERING EVAN C. CONNELL 045488 919.926.2200 econnell@optimaengineering.com Interior walls and partitions 0 HR. ----- G5.01 N/A N/A N/A Mechanical: I3.101 ENLARGED PLANS AND ELEVATIONS 3 DD REVISED PRICING 2020-06-19 Description of assembly: CONCRETE WITH RIGID INSULATION Floor Construction including Sprinkler-Standpipe: N/A I3.102 ENLARGED PLANS AND ELEVATIONS 3 DD REVISED PRICING 2020-06-19 support beams and joists 0 HR. EXISTING EXISTING EXISTING EXISTING EXISTING Structural: N/A I5.201 CEILING DETAILS 3 DD REVISED PRICING 2020-06-19 Floor Ceiling Assembly Retaining Walls>5' High: N/A I5.301 MILLWORK DETAILS 3 DD REVISED PRICING 2020-06-19 U-Value of total assembly: Columns Supporting Floors Other: I5.302 MILLWORK DETAILS 3 DD REVISED PRICING 2020-06-19 R-Value of insulation: 9.5 CI Openings (windows or doors with glazing) Roof construction including supporting beams ("Other" should include firms and individuals such as truss, precast, pre-engineered, interior designers, etc.) U-Valye of assembly: .27 PLUMBING and joists 0 HR. EXISTING EXISTING EXISTING EXISTING EXISTING Solar heat gain coefficient: .23 P0.01 PLUMBING LEGEND, INDEX AND NOTES 3 DD REVISED PRICING 2020-06-19 Projection factor: Roof Ceiling Assembly P0.02 PLUMBING SCHEDULES 3 DD REVISED PRICING 2020-06-19 Door R-Value: Columns Supporting Roof 2018 NC BUILDING CODE: New Building Shell/Core X 1st time interior completion P1.01 CONSTRUCTION - DRAINAGE PIPING PLAN - LEVEL 02 3 DD REVISED PRICING 2020-06-19 Shaft Enclosures- Exit 1 HR. EXISTING EXISTING EXISTING EXISTING EXISTING Addition Phased Construction - Shell/Core Walls below grade (each assembly) P1.02 CONSTRUCTION - DRAINAGE PIPING PLAN - LEVEL 03 3 DD REVISED PRICING 2020-06-19 Shaft Enclosures- Other 1 HR. EXISTING EXISTING EXISTING EXISTING EXISTING P2.01 CONSTRUCTION - SUPPLY PIPING PLAN - LEVEL 02 3 DD REVISED PRICING 2020-06-19 Description of assembly: Corridor Separation 0 HR. N/A N/A N/A N/A N/A 2018 NC EXISTING BUILDING CODE: Prescriptive Alteration Level I Historic Property P2.02 CONSTRUCTION - SUPPLY PIPING PLAN - LEVEL 03 3 DD REVISED PRICING 2020-06-19 Occupancy/Fire Barrier Separation 0 HR. N/A N/A N/A N/A N/A Repair Alteration Level II Change of Use P3.01 WASTE & VENT RISER DIAGRAMS 3 DD REVISED PRICING 2020-06-19 Party/Fire Wall Separation N/A N/A N/A N/A N/A N/A U-Value of total assembly: Chapter 14 Alteration Level III P3.02 DOMESTIC RISER DIAGRAMS 3 DD REVISED PRICING 2020-06-19 Smoke Barrier Separation R-Value of insulation: N/A N/A N/A N/A N/A N/A CONSTRUCTED: (date) CURRENT OCCUPANCY(S) (Ch 3): Smoke Partition MECHANICAL Floors over unconditioned space (each assembly) RENOVATED: (date) PROPOSED OCCUPANCY(S) (Ch 3): Tenant/Dwelling Unit/ M0.01 MECHANICAL LEGEND AND NOTES 3 DD REVISED PRICING 2020-06-19 Description of assembly: Sleeping Unit Seperation N/A N/A N/A N/A N/A N/A M0.02 MECHANICAL SCHEDULES 3 DD REVISED PRICING 2020-06-19 OCCUPANCY CATEGORY (Table 1604.5): PROPOSED: Incidental Use Separation N/A N/A N/A N/A N/A N/A M1.01 DEMOLITION - MECHANICAL PLAN - LEVEL 02 3 DD REVISED PRICING 2020-06-19 * Indicate section number permitting reduction M1.02 DEMOLITION - MECHANICAL PLAN - LEVEL 03 3 DD REVISED PRICING 2020-06-19 U-Value of total assembly: BASIC BUILDING DATA M2.01 CONSTRUCTION - MECHANICAL PLAN - LEVEL 02 3 DD REVISED PRICING 2020-06-19 R-Value of insulation: I-A II-A III-A IV V-A PERCENTAGE OF WALL OPENING CALCULATION Construction Type: M2.02 CONSTRUCTION - MECHANICAL PLAN - LEVEL 03 3 DD REVISED PRICING 2020-06-19 (check all that apply) I-B X II-B III-B V-B M3.01 MECHANICAL DETAILS 3 DD REVISED PRICING 2020-06-19 Floors slab on grade DEGREE OF OPENINGS ALLOWABLE AREA ACTUAL SHOWN ON PLANS Sprinklers: No Partial X NFPA 13 NFPA 13R NFPA 13D Description of assembly: CONCRETE SLAB ON GRADE PROTECTION (%) (%) (TABLE 705.8) Standpipes: No Class: I II X III X WET DRY ELECTRICAL E0.01 ELECTRICAL LEGEND AND NOTES 3 DD REVISED PRICING 2020-06-19 Fire District: No Yes Flood Hazard Area: No Yes E0.02 ELECTRICAL SPECIFICATIONS 3 DD REVISED PRICING 2020-06-19 U-Value of total assembly: Special Inspection Required: No Yes E1.01 DEMOLITION - ELECTRICAL PLAN - LEVEL 02 3 DD REVISED PRICING 2020-06-19 R-Value of insulation: 15 Horizontal/vertical requirement: E1.02 DEMOLITION - ELECTRICAL PLAN - LEVEL 03 3 DD REVISED PRICING 2020-06-19 Slab heated: GROSS BUILDING AREA TABLE: E2.01 CONSTRUCTION - LIGHTING PLAN - LEVEL 02 3 DD REVISED PRICING 2020-06-19 FLOOR EXISTING (SQ FT) NEW (SQ FT) SUB-TOTAL LIFE SAFETY SYSTEM REQUIREMENTS E2.02 CONSTRUCTION - LIGHTING PLAN - LEVEL 03 3 DD REVISED PRICING 2020-06-19 3rd Floor 31,639 E3.01 CONSTRUCTION - POWER PLAN - LEVEL 02 3 DD REVISED PRICING 2020-06-19 STRUCTURAL DESIGN (PROVIDE ON SHEET 1 OR 2 OF THE STRUCTURAL SHEETS) Emergency Lighting: No X Yes 2nd Floor 31,639 E3.02 CONSTRUCTION - POWER PLAN - LEVEL 03 3 DD REVISED PRICING 2020-06-19 Exit Signs: No X Yes Mezzanine E4.01 CONSTRUCTION - EQUIPMENT CONNECTIONS PLAN - LEVEL 02 3 DD REVISED PRICING 2020-06-19 DESIGN LOADS: Fire Alarm: No X Yes 1st Floor 31,639 E4.02 CONSTRUCTION - EQUIPMENT CONNECTIONS PLAN - LEVEL 03 3 DD REVISED PRICING 2020-06-19 Importance Factors: Wind (Iw) Smoke Detection Systems: No X Yes Basement E5.01 ELECTRICAL DETAILS 3 DD REVISED PRICING 2020-06-19 Snow (IS ) E5.02 ELECTRICAL DETAILS 3 DD REVISED PRICING 2020-06-19 Seismic (I E) Carbon Monoxide Detection: X No Yes - - Date Description E5.03 ELECTRICAL DETAILS 3 DD REVISED PRICING 2020-06-19 Panic Hardware: X No Yes E5.04 PANEL SCHEDULES 3 DD REVISED PRICING 2020-06-19 Live Loads: Roof psf - 2 2020-04-24 DD PRICING E5.05 PANEL SCHEDULES 3 DD REVISED PRICING 2020-06-19 Mezzanine psf Floor LIFE SAFETY PLAN REQUIREMENTS TOTAL BUILDING 94,917 3 2020-06-19 DD REVISED PRICING psf E5.06 ELECTRICAL SCHEDULES 3 DD REVISED PRICING 2020-06-19 FA0.01 FIRE ALARM LEGEND AND NOTES 3 DD REVISED PRICING 2020-06-19 Life safety Plan Sheet #: G2.02 & G2.03 ALLOWABLE AREA Ground Snow Load: psf FA1.01 DEMOLITION - FIRE ALARM PLAN - LEVEL 02 3 DD REVISED PRICING 2020-06-19 X Fire and/or smoke rated wall locations (Chapter 7) Primary Occupancies Classification(s): Wind Load: Basic Wind Speed mph (ASCE-7) FA1.02 DEMOLITION - FIRE ALARM PLAN - LEVEL 03 3 DD REVISED PRICING 2020-06-19 Assumed and real property line locations (if not on the site plan) Assembly A-1 A-2 A-3 A-4 A-5 Exposure Category Exterior wall opening area with respect to distance to assumed property lines (705.8) FA2.01 CONSTRUCTION - FIRE ALARM PLAN - LEVEL 02 3 DD REVISED PRICING 2020-06-19 Business X X Occupancy Use for each area as it relates to occupant load calculation (Table 1004.1.2) FA2.02 CONSTRUCTION - FIRE ALARM PLAN - LEVEL 03 3 DD REVISED PRICING 2020-06-19 Educational SEISMIC DESIGN CATEGORY: A B C D X Occupant loads for each area F-1 Moderate F-2 Low Factory X Exit access travel distance (1017) Hazardous H-1 Detonate H-2 Deflagrate H-3 Combust H-4 Health H-5 HPM Provide the following Seismic Design Parameters: X Common path of travel distances (Tables 1006.2.1 & 1006.3.2(1)) Institutional Occupancy Category (Table 1604.5) I II III IV I-1 I-2 I-3 I-4 X Dead end lengths (1020.4) I-1 Condition Spectral Response Acceleration Ss %g S1 %g 1 2 X Clear exit widths for each exit door I-2 Condition Site Classification (ASCE 7) A B C D E F 1 2 X Maximum calculated occupant load capacity each exit door can accommodate base on egress - I-3 Condition Data Source: 1 2 3 4 5 Field Test Presumptive Historical Data width (1005.3) Mercantile Basic structural system (check one) X Actual occupant load for each exit door Residential R-1 R-2 R-3 R-4 Bearing Wall Dual w/Special Moment Frame A separate schematic plan indicating where fire rated floor/ceiling and/or roof structure is provided Storage S-1 Moderate S-2 Low High-piled Building Frame Dual w/Intermediate R/C or Special Steel for porposes of occupancy separation Moment Frame Inverted Pendulum Location of doors with panic hardware (1010.1.10) Parking Garage: Open Enclosed Repair Garage Location of doors with delayed egress locks and amount of delay (1010.1.9.7) Analysis Procedure: Simplified Equivalent Lateral Force Dynamic Utility and Miscellaneous X Location of doors with electromagnetic egress locks (1010.1.9.9) Architectural, Mechanical, Components anchored? Yes No Location of doors equipped with hold-open devices Accessory Occupancy Classification(s): Location of emergency escape windows (1030) Incidental Uses (Table 509): LATERAL DESIGN CONTROL: Earthquake Wind The square footage of each fire area (202) This seperation is not exempt as a Non-Seperated Use (see exceptions). SOIL BEARING CAPACITIES: The square footage of each smoke comparment for Occupancy Classification I-2 (407.5) Field Test (provide copy of test report) Note any code exceptions or table notes that may have been utilized regarding the items above Special Uses (Chapter 4 - List Code Sections): psf Presumptive bearing capacity psf Special Provisions (Chapter 5 - List Code Sections): Pile size, type, and capacity Mixed Occupancy: Separation: Exception: ACCESSIBLE DWELLING UNITS (SECTION 1107) Select one MECHANICAL DESIGN ACCESSIBLE ACCESSIBLE TYPE A TYPE A TYPE B TYPE B TOTAL (PROVIDE ON THE MECHANICAL SHEETS IF APPLICABLE) TOTAL Actual Area of Occupancy A + Actual Area of Occupancy B UNITS UNITS UNITS UNITS UNITS UNITS ACCESSIBLE UNITS < 1 UNITS Allowable Area of Occupancy A Allowable Area of Occupancy B REQUIRED PROVIDED REQUIRED PROVIDED REQUIRED PROVIDED PROVIDED MECHANICAL SYSTEM, SERVICE SYSTEMS AND EQUIPMENT + + = < 1.00 Thermal zone Winter dry bulb: _______________________________ Summer dry bulb: _______________________________ ACCESSIBLE PARKING (A) (B) (C) (D) (SECTION 1106) Description 4 Interior design conditions Story Bldg Area Per Table 506.2 Area For Frontage Allowable Area Per Winter dry bulb: _______________________________ No. And Use Story (Actual) Area Increase 1,5 Story or Unlimited 2,3 Summer dry bulb: _______________________________ Total # of Parking Spaces # of Accessible Spaces Provided Total # Lot or Parking REFER TO MECHANICAL DRAWINGS M SERIES Relative humidity: _______________________________ Area Required Provided Regular with 5' Access Aisle VAN SPACES WITH 132" Access 8' Access Accessible Provided 2 BUSINESS 31,639 69,000 N/A 69,000 Building heating load: Aisle Aisle 3 BUSINESS 31,639 69,000 N/A 69,000 BIM 360://090.0338.100 - UCB Biosciences Workplace Design and Doc/Interiors - 090.0338.000 - _UCB Biosciences.rvt Building cooling load: Mechanical Spacing Conditioning System Total 424 (EXIST) 6 4 10 Seal / Signature Unitary description of unit: 1 Frontage area increases from Section 506.2 are computed thus: heating efficiency: a.Perimeter which fronts a public way or open space having 20 feet minimum width = _____ ft (F) PLUMBING FIXTURE REQUIREMENTS b.Total Building Perimeter = _____ ft (P) colling efficiency: (TABLE 2902.1) size category of unit: BOILER size category. If oversized, state reason: USE WATERCLOSETS URINALS LAVATORIES SHOWERS DRINKING FOUNTAINS c.Ratio (F/P) = _____ (F/P) d.W = Minimum width of public way = _____ ft (W) 2 Unlimited area applicable under conditions 507. NOT FOR / TUBS Chiller size category. If oversized, state reason: EXIST'G MALE FEMALE UNISEX 6 10 4 MALE FEMALE UNISEX 6 6 REGULAR 2 ACCESSIBLE 2 3 Maximum Building Area = total number of stories in the building x D (maximum 3 stories) (506.2). 4 The maximum area of open parking garages must comply with 406.5.4. The maximum area of air traffic control towers must comply with 412.3.1. CONSTRUCTION 5 Frontage increase is based on the unsprinklered area value in Table 506.2. List equipment efficiencies: SPACE NEW 2 6 6 2 1 2 REQ'D 6 11 4 6 6 3 4 ALLOWABLE HEIGHT Project Name ELECTRICAL DESIGN (PROVIDE ON THE ELECTRICAL SHEETS IF APPLICABLE) SPECIAL APPROVALS ALLOWABLE SHOWN ON PLANS CODE REFERENCE UCB BIOSCIENCES ELECTRICAL SYSTEM, AND EQUIPMENT Special Approval: (Local Jurisdiction, Department of Insurance, OSC, DPI, DHHS, etc., describe below) Building Height in Feet (Table 504.3) 75' Method of compliance: Building Height in Stories (Table 504.4) 4 Project Number Provide code reference if the "Shown on Plans"quantity is not based on Table 504.3 or 504.4. Lighting Schedule (each fixture type) lamp type required in fixture 090.0338.000 REFER TO ELECTRICAL DRAWINGS E SERIES number of lamps in fixture ballast type used in the fixture Description number of ballasts in fixture total wattage per fixture APPENDIX B total interior wattage specified vs. allowed (whole building of space by space) total exterior wattage specified vs. allowed Additional Prescriptive Compliance 506.2.1 More Efficient Mechanical Equipment 506.2.2 Reduced Lighting Power Density Scale 506.2.3 Energy Recovery Ventilation System 506.2.4 Higher Efficiency Service Water Heater 12" = 1'-0" 506.2.5 On-Site Supply of Renewable Energy 506.2.6 Automatic Daylighting Control Systems 6/19/2020 5:16:50 PM G0.02 © 2020 Gensler
ABBREVIATIONS GRAPHIC SYMBOLS GRAPHIC SYMBOLS GRAPHIC SYMBOLS VICINITY MAP UCB & AND SECTION INDICATIONS REFLECTED CEILING GENERAL ACCESS ACOUS ACCESSORY ACOUSTIC(AL) ELAST ELEC ELASTOMERIC ELECTRICAL JAN JANITOR RD RDL ROOF DRAIN ROOF DRAIN LEADER ACOUSTICAL CEILING TILE PLAN NORTH BIOSCIENCES AFF ABOVE FINISHED FLOOR EMBED EMBEDD(ED)(ING) KIT KITCHEN RDR READER ACOUSTICAL CEILING AND GRID TRUE NORTH (IF DIFFERENT THAN PLAN NORTH) 4000 Paramount Pkwy AL ALUMINUM ENGR ENGINEER(ED) RECES RECESSED Suite 200 & 300 ALT ALTERNATE ENTR ENTRANCE LAV LAVATORY RECPT RECEPTACLE ALUMINUM ANNUNC ANNUNCIATOR EQ EQUAL LB POUND REF REFER(ENCE) AREA NOT IN CONTRACT / Morrisville, NC 27560 OUTSIDE THE SCOPE OF WORK ANOD ANODIZED EQUIP EQUIPMENT LP LOW POINT REFL REFLECTED BRICK GYPSUM BOARD OR PLASTER APPL APPLIANCE EXIST EXISTING LT LIGHT REFR REFRIGERATOR ARCH ARCHITECT(URAL) EXP JT EXPANSION JOINT LVLG LEVELING REINF REINFORCED(D)(ING)(MENT) xx'-xx" 1 AUTO AUTOMATIC EXPS EXPOSED(D) LVT LOUVER REQD REQUIRED CARPET COLUMN GRID REFERENCE NUMBER CEILING HEIGHT CHANGE SYMBOL AVG AVERAGE EXT EXTERIOR £ BRITISH POUND (CURRENCY) RESIL RESILIENT COLUMN GRID LINES AND REFERENCE NUMBER xx'-xx" RESIS RESIST(ANT)(IVE) CONCRETE X'-X" EXISTING CONSTRUCTION TO REMAIN BD BOARD FAB FABRICATION MAX MAXIMUM RFG ROOFING FINISHED CEILING HEIGHT BLDG BUILDING FD FLOOR DRAIN MECH MECHANICAL RM ROOM EXISTING CONSTRUCTION TO BE DEMOLISHED CONCRETE MASONRY UNIT GRID STARTPOINT 613 Hillsborough St. Tel 919.239.7828 BLKG BLOCKING FE FIRE EXTINGUISHER MEMB MEMBRANE RO ROUGH OPENING NEW PARTITION Raleigh, NC 27603 Fax 919.239.7829 BOLLD BOLLARD FE&C FIRE EXTINGUISHER AND CABINET MET METAL APC1 CEILING FINISH TAG 1 HR FIRE RATED PARTITION United States BRDLM BROADLOOM FHC FIRE HOSE AND CABINET MEZZ MEZZANINE SCR SCRIBE CUT STONE CEILING TAG 2 HR FIRE RATED PARTITION BU BUILT UP FIN FINISH MFD MANUFACTURED SECUR SECURITY FLDG FOLDING MFR MANUFACTURER SF SQUARE FEET APC1 CEILING FINISH 3 HR FIRE RATED PARTITION EARTH 10'-0" CEILING HEIGHT CAB CABINET FLR FLOOR(ING) MIN MINIMUM SG SINGLE 4 HR FIRE RATED PARTITION CEM CEMENT(ITIOUS) FPLC FIREPLACE MISC MISCELLANEOUS SHORG SHORING S SPEAKER MILLWORK CER CERAMIC FR FIRE RAT(ING)(ED) MLWK MILLWORK SIM SIMILAR FABRIC WRAPPED PANEL CIP CAST-IN-PLACE FRMG FRAMING MOIST MOISTURE SST STAINLESS STEEL MILLWORK ABOVE SECURITY CAMERA CLG CEILING FURN FURNITURE MOT MOTOR(IZED) STD STANDARD GLASS CMU CONCRETE MASONRY UNIT FWC FABRIC WALL COVERING MTD MOUNTED STL STEEL DETAIL NUMBER EXIT SIGN XX COATG COATING FXD FIXED STRFR STOREFRONT GRAVEL XX.XXX SHEET NUMBER COILG COILING FXTR FIXTURE NIC NOT IN CONTRCT STRUCT STRUCTURAL E DENOTES EXISTING TO REMAIN SIM CONC CONCRETE NO NUMBER SURF SURFACE DESCRIPTION OF SIMILAR OR OPPOSITE CONSTR CONSTRUCTION GA GAUGE NTS NOT TO SCALE SUSP SUSPENDED R DENOTES EXISTING TO BE RELOCATED GYPSUM PLASTER CONT CONTINUOUS(ATION) GFRC GLASS FIBER REINFORCED SYS SYSTEM(S) AREA TO BE DETAILED CONCRETE HINGED ACCESS PANEL CONTR CONTRACT(OR) OPNG OPENING(S) COV COVER GFRG GLASS FIBER REINFORCED GYPSUM OPR OPERABLE T&G TOUNGUE AND GROOVE INSULATION (LOOSE OR BATT) LOCATION ON SHEET WHERE ELEVATION IS SHOWN CPT CARPET GFRP GLAS FIBER REINFORCED PLASTER ORD OVERFLOW ROOF DRAIN THK THICK 1 GL GLASS ORNA ORNAMENTAL TLT TOILET LIGHT FIXTURES DIRECTION OF ELEVATION LOCATION MAP INSULATION (RIGID) $ DOLLAR (US CURRENCY) GR GRAD(E)(ING) OVFL OVERVLOW TRAF TRAFFIC LAY-IN LIGHT FIXTURE 2 A11.XX SHEET NUMBER WHERE ELEVATION IS SHOWN DBL DOUBLE GYP GYPSUM OVHD OVERHEAD TRANS TRANSPARENT LINEAR STRIP FIXTURE INTERIOR AND EXTERIOR ELEVATION MARKER DEPT DEPARTMENT TRTD TREATED METAL DES DESIGN(ED) HD HEAD PBD PARITICLE BOARD TYP TYPICAL LINEAR PENDANT FIXTURE 1 DET DETAIL HDWD HARDWOOD PEDR PEDESTRIAN RECESSED DOWNLIGHT REVISION REFERENCE NUMBER PLASTIC DF DRINKING FOUNTAIN HDWE HARDWARE PLAM PLASTIC LAMINATE UNDRLAY UNDERLAYMENT RECESSED ADJUSTABLE DOWNLIGHT DIA DIAMETER HM HOLLOW METAL PLAS PLASTER UNO UNLESS NOTED OTHERWISE REVISION CLOUD ENCLOSING AREA REVISED PLYWOOD RECESSED WALL WASHER DIFF DIFFUSER HORIZ HORIZONTAL PLSTC PLASTIC UTIL UTILITY HP HIGH POINT TRACK LIGHTING NAME DIM DIMENSION PLYWD PLYWOOD ROOM NAME HVAC HEATING, VENTILATIING, AND AIR SURFACE MOUNTED LIGHT FIXTURE DISP DISPENSER PNL PANEL VEH VECHICLE PRE-CAST PANELS 1234 ROOM NUMBER DIV DIVISION CONDITIONING POLYST POLYSTRENE VERT VERTICAL AREA ROOM AREA (SQ FT) WALL SCONCE DN DOWN PORT PORTABLE VIF VERIFY IN FIELD 01 SHEETNOTE REFERENCE INFILTR INFILTRATION SAND OR GROUT MECHANICAL FIXTURES DR DOOR PREFAB PREFABRICATED DSCON DISCONNECT INFO INFORMATION PREFIN PREFINISHED W/ WITH 1 A3A WALL TYPE REFERENCE INSTRUM INSTRUMENT(ATION) RETURN AIR DWG DRAWER PRTECN PROTECTION W/O WITHOUT STONE FIRE RATING INSUL INSULATION PTN PARTITION WC WATER CLOSET SUPPLY AIR XXX DOOR REFERENCE NUMBER (REFER TO DOOR SCHEDULE) INT INTERIOR WD WOOD INTLK INTERLOCK(ING) WOOD (FINISHED ) WDW WINDOW CIRCULAR DIFFUSER XX DOOR NUMBER WT WEIGHT LINEAR DIFFUSER XX DOOR TYPE WTRPRF WATERPROOFING WOOD (CONTINUOUS MEMBER) DOOR NUMBER XXX X X DOOR TYPE | HARDWARE TYPE WOOD (INTERRUPTED MEMBER XX WINDOW REFERENCE NUMBER (REFER TO WINDOW SCHEDULE) MW01 MILLWORK REFERENCE NUMBER (REFER TO MILLWORK SCHEDULE) DEVICE MOUNTING DIAGRAMS PROJECT SCOPE ELEVATION DATUM REFERENCE FOLLOWING ARE THE PLANS OUTLINING THE SCOPE OF WORK REQUIRED FOR INTERIOR TENANT WORK TO +6" INCLUDE SELECT DEMOLITION & CONSTRUCTION OF NEW PARTITIONS, CEILINGS, FINISHES, MECHANICAL, Date Description NOTE: FLOOR ELEVATION TRANSITION ELECTRICAL, PLUMBING & FIRE PROTECTION AS INDICATED ON DRAWINGS. IF THE COUNTER IS DEEPER THAN 24", PROVIDE 0" 2 2020-04-24 DD PRICING EDGE OF WALL, DOOR EDGE OF WALL, DOOR CONVENIENCE OUTLETS ON THE END WALL ACCESSIBLE FRAME, OR OPENING FRAME, OR OPENING TOILET ACCESSORY TAG THE DRAWINGS, IN CONCERT WITH THE PROJECT MANUAL, COMPRISE THE CONTRACT DOCUMENTS 3 2020-06-19 DD REVISED PRICING REACH RANGE. TA__ OUTLINING THE INTENT OF THE ARCHITECT, AND MAY BE SUPPLEMENTED BY FURTHER INFORMATION EQ P__ PLUMBING FIXTURE TAG ISSUED BY ARCHITECT. UNLESS SPECIFIC DIMENSIONS ARE INDICATED A B WALL DEVICE MOUNTING HEIGHTS ALIGN CENTERS OF ALIGN CENTERS OF DEVICES EQ EQ DEVICES OR GROUPS OF OR GROUPS OF DEVICES. (TYPICALLY TO COORDINATE WITH EQUIPMENT), EQUIPMENT TAG THE DRAWINGS ARE ARRANGED IN GENERAL TO SPECIFIC ORDER, FOLLOWING A TOP TO BOTTOM, RIGHT B DEVICE TYPE HEIGHT 1__ DEVICES. CENTER DEVICES OR GROUPS OF DEVICES WITHIN TO LEFT FORMAT. CONTRACTORS ARE ADVISED TO READ AND FAMILARIZE THEMSELVES WITH THE WIDTH OR DEPTH OF MILLWORK ALL DEVICES INFORMATION IN THE PROJECT MANUAL, AS WELL AS THE GENERAL LEGENDS CONTAINED IN THE G SERIES GANG TOGETHER MULTIPLE OCCURING AT FIRE ALARM STROBE/HORN 7' - 6" OF DRAWINGS, PRIOR TO REVIEW OF THE PLANS, ELEVATIONS AND DETAILS. ADVISE THE ARCHITECT GANG TOGETHER MULTIPLE DEVICES OF THE SAME EQ EQ 8" ABOVE COUNTERTOP OR (IF MILLWORK SHALL BE NON-ADJUSTABLE SENSOR 4' - 6" WHERE INTENT IS NOT CLEARLY PERCEIVED, PRIOR TO PROCEEDING WITH WORK. DEVICES OF THE SAME TYPE. HORIZONTAL TYPE. APPLICABLE) ABOVE TOP OF COUNTER'S BACKSPLASH ORIENTATION THERMOSTAT INTERCOM 3' - 10" 3' - 10" FINISH 4" SECURITY ALARM PANEL 3' - 10" XXXX WALL FINISH TAG A CARD READER 3' - 6" EQ XXXX BASE FINISH TAG WHERE INCLUDED FOR UNDER- FIRE ALARM PULL STATION 3' - 6" COUNTER EQUIPMENT, COORDINATE EXTENT OF FINISH TYP. 8" DOOR RELEASE BUTTON 3' - 6" DEVICE PLACEMENT WITH EQUIPMENT LOCATIONS. FOR CONVENIENCE TELEPHONE 3' - 6" WALL FINISH TAG XXXX DEVICES, CENTER AND SPACE EVENLY ROOM SCHEDULER 3' - 6" ALONG WIDTH OF COUNTER LIGHT CONTROL 3' - 2" POWER AND DATA DEVICES AV CONTROL PANEL 3' - 2" XXXX SPECIAL FINISH TAG NOT ASSOCIATED WITH DOOR OPERATOR BUTTON 3' - 2" MILLWORK SHALL BE IN TYPICAL POWER RECEPTACLE 1' - 6" XXXX FLOOR FINISH TAG VERTICAL ORIENTATION TYPICAL DATA JACK 1' - 6" AT COLUMNS OR BETWEEN DOORS, FRAMES, AT EDGE OF WALL, DOOR, FRAME, OPENING, ALL HEIGHTS TO CENTERLINES OF DEVICES CHANGE IN FLOOR FINISH OPENINGS, OR OTHER ELEMENTS OR OTHER ELEMENTS SIGNAGE MOUNTING DIAGRAMS SHOWER MOUNTING DIAGRAMS PLUMBING FIXTURE AND ACCESSORY MOUNTING DIAGRAMS 5' - 0" MINIMUM BACK WALL 2' - 6" MINIMUM FINISHED FACE OF BACK WALL FINISHED FACE OF SIDE WALL 11" 1' - 4" 3' - 4" SIGN CONTROL AREA 1' - 0" 3' - 6" BIM 360://090.0338.100 - UCB Biosciences Workplace Design and Doc/Interiors - 090.0338.000 - _UCB Biosciences.rvt 1' - 6" 3' - 0" 6" MIRROR 10" 3' - 0" MINIMUM GRAB BAR Seal / Signature 6" INACTIVE LEAF ACTIVE LEAF REFLECTING SURFACE CLEAR AREA 3' - 4" - BOTTOM OF 5' - 0" 2' - 11" TYPICAL 2' - 11" TYPICAL 1' - 6" 8" 8" 3' - 4" CLEAR AREA NOT FOR 3' - 2" 3' - 0" 2' - 10" 2' - 3" MIN 2' - 3" MIN 2' - 0" 5' - 0" MINIMUM 1' - 4" 1' - 5" 7" 11" 11" FINISHED FLOOR CONSTRUCTION ACCESSIBLE SHOWER ACCESSIBLE TOILET URINAL - TYPICAL URINAL - ACCESSIBLE ACCESSIBLE TOILET DRINKING FOUNTAIN LAVATORY DOUBLE DOOR WITH ONE ACTIVE LEAF BACK WALL SIDE WALL BACK WALL PLAN VIEW - ROLL-IN SHOWER TYPE ALL DIMENSIONS ARE TO FACE OF FINISH Project Name EQ EQ 3' - 0" 2" 2" UCB BIOSCIENCES BACK WALL CURTAIN CURTAIN ROD Project Number CONTROL WALL ROD SHOWER HEAD 090.0338.000 3' - 0" 3' - 0" 8" 3" Description SIGN CONTROL SOAP DISH OR SHELF, AREA IF APPLICABLE VICINITY & LOCATION MAPS, 1' - 6" 1' - 6" PROJECT INFO. & SCOPE, GRAPHIC 7' - 0" 10" GRAB BAR CONTROLS SYMBOLS & ABBREVIATION 3' - 0" MINIMUM 4' - 10" - TYPICAL GRAB BAR HEIGHT FOR REFERENCE 3' - 10" - ACCESSIBLE 5' - 6" 4' - 6" CLEAR AREA Scale 2' - 11" TYPICAL 4' - 0" 4' - 6" 4' - 0" SEAT 3' - 9" 3' - 6" 3' - 4" 3' - 4" 3' - 3" 3' - 2" As indicated 3' - 0" 2' - 6" 1' - 6 1/2" 1' - 7" 1' - 7" 6/19/2020 5:17:04 PM 4' - 0" MINIMUM FINISHED FLOOR SINGLE DOOR OR DOUBLE DOOR WITH TWO ACTIVE LEAVES ACCESSIBLE SHOWER PLAN VIEW - TRANSFER SHOWER TYPE ALL DIMENSIONS ARE TO FACE OF FINISH BACK WALL CONTROL WALL TYPICAL (NON-ACCESSIBLE) SHOWER CONTROL WALL WASTE / TOWEL COMBO UNIT TOWEL DISPENSER WASTE RECEPTACLE SANITARY VENDOR COMBINATION DISPENSER TOILET TISSUE DISPENSER SANITARY DISPOSAL SEAT COVER DISPENSER ROBE, COAT, OR TOWEL HOOK HAND DRYER SOAP DISPENSER FEC OR FHVC SHELF & MOP HOLDER G1.01 © 2020 Gensler
UCB BIOSCIENCES 4000 Paramount Pkwy Suite 200 & 300 Morrisville, NC 27560 613 Hillsborough St. Tel 919.239.7828 Raleigh, NC 27603 Fax 919.239.7829 United States BUBBLE MAIL RECEPTION 2002 2047 FURN 2001 STORAGE FEC 2022 TRAINING B LG CONF BUBBLE 2021B TRAINING A 2003 2045 2021A COMMON PATH OF TRAVEL 36' - 0" LIBRARY INTERVIEW 2040 2011 BUBBLE LG CONF 2043 2003 = E /3 430 SF C T AN TION IS A A L D PAR N E PIONEER IAGO XIT SCOLLAB BUBBLE D E 3" IN 2010 2041 '0 - 9" M 20 6' - 6 SM CONF 2004 PHONE 2032 LIBRARY VESTIBULE 2030 5' - 6" PHONE TRAVEL DISTANCE 2031 115' - 5" FEC WAR ROOM 34 0.15 2012 BUBBLE PHONE PHONE 48 0.2 145 FEC 2051 2024 2023 187 WELLNESS RESTROOM RESTROOM JAN 2" STORAGE 2018 2017 2015 92' - = 2012A ON BUBBLE RATI A 2053 EP EX IT S COLLAB CORRIDOR 2050 2013 ELEC 217 SF WELLNESS 2019 48 0.2 BUBBLE 188 STORAGE STORAGE SERVER 2055 2020 2016 2014 Date Description 2 2020-04-24 DD PRICING 3 2020-06-19 DD REVISED PRICING PHONE 2052 FEC PHONE BUBBLE 34 0.15 2054 2061 145 FUTURE BUBBLE BUSINESS USE 2063 TENANT LIBRARY 15090 SF 2060 BUBBLE 2065 BUBBLE 2067 BUBBLE 2069 01 EGRESS & OCCUPANCY PLAN - LEVEL 02 SCALE: 1/8" = 1'-0" BIM 360://090.0338.100 - UCB Biosciences Workplace Design and Doc/Interiors - 090.0338.000 - _UCB Biosciences.rvt GRAPHIC SYMBOLS LEGEND OCCUPANT LOAD CALCULATION - LEVEL 02 EGRESS REQUIREMENTS - LEVEL 02 TOILET FIXTURE REQUIREMENTS - LEVEL 02 GENERAL NOTES Seal / Signature AREA TOTAL GROSS AREA OF TENANT - ENTIRE FLOOR: APPROX. 31,639 SF FIXTURES REQUIRED PROVIDED 1. AREAS TONED IN SOLID GRAY ARE NOT IN CONTRACT. EGRESS WIDTH LOAD FACTOR IBC TABLE 1004.1.1 TRAVEL DISTANCE 2. FIRE EXTINGUISHER, EXIT SIGN, & FIRE ALARM DEVICE LOCATIONS ARE SHOWN FOR TOTAL AREA IN SCOPE: APPROX. 12,924 SF WATER CLOSETS 8 10 REFERENCE, INTENDED EGRESS, & DESIGN INTENT. FINAL DEVICE LOCATIONS ARE 00 00 ASSEMBLY - UNCONCENTRATED SUBJECT TO REVIEW WITH FIRE MARSHAL/INSPECTORS. REVIEW WITH INSPECTORS COMMON PATH OF TRAVEL ONE-HOUR FIRE RATED PARTITION 00 (15NSF/OCCUPANT): BREAK 217 NET SF 15 OCC TENANT OCCUPANCY: 138 OCCUPANTS 290 OCCUPANTS FULL FLOOR LAVATORIES 5 6 DURING ROUGH-IN TO CONFIRM LOCATIONS & QUANTITIES. NOT FOR LOAD CAPACITY IBC TABLE 1004.1.1 DRINKING FOUNTAINS 3 3 EXIT ACCESSORY (300 GSF/OCCUPANT): STORAGES & SERVER 418 GROSS SF 2 OCC EGRESS WIDTH REQUIREMENTS: IBC TABLE 1005.1 EXCEPTION 2 IPC SECTION 410.1 CONSTRUCTION OTHER EGRESS COMPONENTS BUSINESS (100 GSF/OCCUPANT): REQUIRED (.15 IN/OCCUPANT): 44 INCHES GENERAL OFFICE 15,090 GROSS SF 121 OCC PROVIDED AT EXIT STAIR DOORS: 68 INCHES EXIT STAIR WIDTH Project Name TOTAL TENANT OCCUPANT 138 OCC REQUIRED (.2 IN/OCCUPANT) 58 INCHES OCCUPANCY CLASSIFICATION LEGEND PROVIDED AT EXIT STAIRS: 92 INCHES UCB BIOSCIENCES WHITE BOX TENANT 15,089 GROSS SF 151 OCC ELECTRICAL & JANITOR 228 GROSS SF 1 OCC MINIMUM WIDTH OF EGRESS CORRIDOR REQUIRED: 44 INCHES ASSEMBLY (NON-CONCENTRATED) - 1 PERSON/15SF IBC 1018.2 TOTAL OCCUPANT 290 OCC Project Number MINIMUM WIDTH OF EGRESS CORRIDOR PROVIDED: 60 INCHES BUSINESS - 1 PERSON/100 SF MINIMUM NUMBER OF EXITS REQUIRED: 2 EXITS 090.0338.000 IBC TABLE 1021.1 Description ACCESSORY (STORAGE / MECHANICAL) - 1 PERSON/300 SF NUMBER OF EXITS PROVIDED: 2 EXITS EGRESS & OCCUPANCY PLAN - MAXIMUM LENGTH OF EGRESS TRAVEL: 300 FEET LEVEL 02 IBC TABLE 1016.1 MAXIMUM COMMON PATH OF TRAVEL: 100 FEET IBC 1014.3 EXCEPTION 1 Scale MAXIMUM DEAD END CORRIDOR: 50 FEET As indicated IBC 1018.4 EXCEPTION 2 ACCESS CONTROLLED HARDWARE (ELECTROMAGNETIC LOCK - FAIL OPEN) MEETING ALL 6/19/2020 5:17:31 PM REQUIREMENTS OF IBC 1008.1.4.4. EGRESS & OCCUPANCY CALCULATION - LEVEL 02 G2.02 02 SCALE: 1 1/2" = 1'-0" © 2020 Gensler
UCB BIOSCIENCES 4000 Paramount Pkwy Suite 200 & 300 Morrisville, NC 27560 613 Hillsborough St. Tel 919.239.7828 Raleigh, NC 27603 Fax 919.239.7829 United States HR SUITE PHONE PHONE TREADMILL 3096 3091 3081 3021 COMMON PATH OF TRAVEL 33' - 8" OPEN BUBBLE BUBBLE BUBBLE OFFICE 3023 3093 3083 OPEN OPEN 3020 WORK CAFE OFFICE 3001 OFFICE 3090 3080 HUDDLE HUDDLE HUDDLE HUDDLE 3024 VENDING 3094 3084 3097 3002 COLLAB 34 0.15 34 0.15 34 0.15 34 0.15 BOOTHS 25 25 25 25 3095 34 0.15 FEC FEC FEC FEC 246 SM CONF 3085 LG CONF MD CONF MD CONF PHONE STORAGE 48 0.2 3076 3026 3025 3008 3003 450 SF 246 HALO 165 SF 3" 48 0.2 CONFERENCE 271' - JAN 3006 /3 = N AL 247 GO LL DIA ELEC ERA COPY/COLLAB OV ELEVATOR COPY/COLLAB 3028 IT 3078 LOBBY 607 SF WORKROOM 3000 3005 53' - 2" EP ARATION = 1 SM CONF SM CONF STORAGE SERVER EXIT S PHONE 3036 3035 3004 MD CONF Date Description 3048 3067 3075 2 2020-04-24 DD PRICING 34 0.15 3 2020-06-19 DD REVISED PRICING FEC FEC EXIST. FEC TRAVEL DISTANCE COLLAB 247 FEC 164' - 4" BOOTHS 3065 BUBBLE 3054 HUDDLE HUDDLE 3064 3074 BUBBLE 3053 OPEN OPEN OPEN OFFICE OPEN OFFICE BUBBLE BUBBLE OFFICE OFFICE 3030 3070 3033 3043 3040 3060 BUBBLE CREATIVE 3063 WORK BUBBLE 3050 3052 BUBBLE BUBBLE 3032 3042 BUBBLE 3072 HUDDLE 3051 PHONE PHONE TREADMILL TREADMILL 3031 3041 3061 3071 01 EGRESS & OCCUPANCY PLAN - LEVEL 03 SCALE: 1/8" = 1'-0" BIM 360://090.0338.100 - UCB Biosciences Workplace Design and Doc/Interiors - 090.0338.000 - _UCB Biosciences.rvt GRAPHIC SYMBOLS LEGEND OCCUPANT LOAD CALCULATION - LEVEL 03 EGRESS REQUIREMENTS - LEVEL 02 TOILET FIXTURE REQUIREMENTS - LEVEL 02 GENERAL NOTES Seal / Signature AREA TOTAL GROSS AREA OF TENANT - ENTIRE FLOOR: APPROX. 31,639 SF FIXTURES REQUIRED PROVIDED 1. AREAS TONED IN SOLID GRAY ARE NOT IN CONTRACT. EGRESS WIDTH LOAD FACTOR IBC TABLE 1004.1.1 TRAVEL DISTANCE 2. FIRE EXTINGUISHER, EXIT SIGN, & FIRE ALARM DEVICE LOCATIONS ARE SHOWN FOR TOTAL AREA IN SCOPE: APPROX. 30,978 SF WATER CLOSETS 11 12 REFERENCE, INTENDED EGRESS, & DESIGN INTENT. FINAL DEVICE LOCATIONS ARE 00 00 ASSEMBLY - UNCONCENTRATED SUBJECT TO REVIEW WITH FIRE MARSHAL/INSPECTORS. REVIEW WITH INSPECTORS COMMON PATH OF TRAVEL 00 (15NSF/OCCUPANT): WORK CAFE 727 NET SF 49 OCC TENANT OCCUPANCY: 415 OCCUPANTS IBC TABLE 1004.1.1 LAVATORIES 7 8 DURING ROUGH-IN TO CONFIRM LOCATIONS & QUANTITIES. NOT FOR LOAD CAPACITY DRINKING FOUNTAINS 4 4 OCCUPANCY CLASSIFICATION LEGEND ASSEMBLY - CONCENTRATED CHAIRS ONLY NOT FIXTED: EGRESS WIDTH REQUIREMENTS: OTHER EGRESS COMPONENTS IBC TABLE 1005.1 EXCEPTION 2 IPC SECTION 410.1 CONSTRUCTION TRAINING 90 OCC REQUIRED (.15 IN/OCCUPANT): 62.25 INCHES PROVIDED AT EXIT STAIR DOORS: 68 INCHES ASSEMBLY (NON-CONCENTRATED) - 1 PERSON/15SF ACCESSORY (300 GSF/OCCUPANT): EXIT STAIR WIDTH STORAGES, SERVER, ELEC & JAN 997 GROSS SF 4 OCC REQUIRED (.2 IN/OCCUPANT) 83 INCHES Project Name PROVIDED AT EXIT STAIRS: 92 INCHES ASSEMBLY (CONCENTRATED - CHAIRS ONLY NOT FIXED) - 1 PERSON/7SF BUSINESS (100 GSF/OCCUPANT): GENERAL OFFICE 27,148 GROSS SF 272 OCC MINIMUM WIDTH OF EGRESS CORRIDOR REQUIRED: 44 INCHES UCB BIOSCIENCES IBC 1018.2 BUSINESS - 1 PERSON/100 SF TOTAL TENANT OCCUPANT 415 OCC MINIMUM WIDTH OF EGRESS CORRIDOR PROVIDED: 60 INCHES Project Number ACCESSORY (STORAGE / MECHANICAL) - 1 PERSON/300 SF MINIMUM NUMBER OF EXITS REQUIRED: 2 EXITS IBC TABLE 1021.1 090.0338.000 Description NUMBER OF EXITS PROVIDED: 2 EXITS EGRESS & OCCUPANCY PLAN - MAXIMUM LENGTH OF EGRESS TRAVEL: 300 FEET IBC TABLE 1016.1 LEVEL 03 MAXIMUM COMMON PATH OF TRAVEL: 100 FEET IBC 1014.3 EXCEPTION 1 Scale MAXIMUM DEAD END CORRIDOR: 50 FEET IBC 1018.4 EXCEPTION 2 As indicated ACCESS CONTROLLED HARDWARE (ELECTROMAGNETIC LOCK - FAIL OPEN) MEETING ALL REQUIREMENTS OF IBC 1008.1.4.4. 6/19/2020 5:17:51 PM EGRESS & OCCUPANCY CALCULATION - LEVEL 03 G2.03 02 SCALE: 1 1/2" = 1'-0" © 2020 Gensler
GENERAL NOTES 02 41 19.D02 02 41 19.D02 UCB 1. ISOLATE NON-LOAD-BEARING FRAMING FROM STRUCTURAL EXISTING SLAB TO REMAIN 09 29 00.F02 EXISTING SLAB TO REMAIN 09 29 00.F02 ELEMENTS TO PREVENT TRANSFER OF DEFLECTION LOADS TO PARTITIONS. STOP STUDS 3/4" BELOW CEILING RUNNERS (TOP TRACKS). DO NOT ATTACH STUDS TO TOP TRACK. DO BIOSCIENCES PRE-FORMED MINERAL WOOL WALL PRE-FORMED MINERAL WOOL WALL NOT ATTACH GYPSUM BOARD TO DEFLECTION TRACK. STOP 4000 Paramount Pkwy PLUG PLUG 09 22 16.A03 09 22 16.A03 GYPSUM BOARD 3/4" BELOW DECK. UL DETAIL REQUIREMENTS Suite 200 & 300 TAKE PRECEDENCE OVER DIMENSIONS LISTED HERE. FLAT STRAP & BACKING PLATE FLAT STRAP & BACKING PLATE Morrisville, NC 27560 09 29 00.G00 09 29 00.G00 2. COORDINATE PARTITION LAYOUT WITH SPECIFIED FINISHES CONTINUOUS ACOUS SEALANT CONTINUOUS ACOUS SEALANT AND PANELING TO ENSURE REQUIRED CLEARANCES ARE PROVIDED. 09 22 16.A11 09 22 16.A11 3. FOLLOW STUD MANUFACTURER'S GUIDELINES FOR FRAMING SLIP-TYPE HEAD JOINT SLIP-TYPE HEAD JOINT LIMITING LENGTHS. REFER TO PROJECT MANUAL FOR 09 29 00.F00 FRAMING DEFLECTION CRITERIA. 09 29 00.F00 SOUND ATTENUATION BLANKET SOUND ATTENUATION BLANKET PARTITIONS WITH ASSIGNED STC RATINGS SHALL: SCHEDULED CEILING, REFER SCHEDULED CEILING, REFER 1. BE CONSTRUCTED TO ACHIEVE INDICATED STC RATINGS PER 613 Hillsborough St. Tel 919.239.7828 TO REFLECTED CEILING PLAN MAJOR TESTING AGENCY METHODS & DETAILS. Raleigh, NC 27603 Fax 919.239.7829 TO REFLECTED CEILING PLAN 2. HAVE STAGGERED GYPSUM BOARD JOINTS, WITHIN EACH United States 09 29 00.A01 09 22 16.A00 LAYER & BETWEEN MULTIPLE LAYERS. GYP BD 5/8" METAL STUD 3. HAVE ACOUSTICALLY SEALED JOINTS AT FLOORS, SIDES, & 09 29 00.A01 TOPS. 09 22 16.A00 GYP BD 5/8" METAL STUD VARIES 4. HAVE ELECTRICAL & LOW VOLTAGE BOXES ON OPPOSITE SIDES OF THE PARTITION BE STAGGERED, SEPARATED BY AT REFER TO PLAN(S) LEAST ONE STUD, AND FULLY SEALED WITH SOUNDLINERS/PUTTY PADS. 5. HAVE ACOUSTICAL SEALANT AT ALL PENETRATIONS; MINIMIZE SIZE OF PENETRATION OPENINGS IN GYPSUM BOARD. 05 D-T01 01 A-T01 1. FIRE-RATED PARTITIONS SHALL COMPLY WITH THE... CONSTRUCT TO ENSURE CONTINUITY OF REQUIRED SCALE: 3" = 1'-0" SCALE: 3" = 1'-0" FIRE-RATING(S). MORE STRINGENT FIRE RATINGS TAKE PRIORITY OVER LESS STRINGENT CONSTRUCTION. FIRE-RATED CONSTRUCTION SHALL BE COMPLETE PRIOR TO INTERSECTING NON-RATED PARTITIONS. 2. GAGES, SIZES, FASTENERS, & QUANTITATIVE NOTES & SPECIFICATIONS ARE MINIMUMS FOR FIRE RATING REQUIREMENTS. UL DETAIL DEFINES MINIMUM REQUIREMENTS FOR GAGES, SIZES, & FASTENERS. IF 02 41 19.D02 CONFLICTS EXIST BETWEEN ANY SPECIFICATIONS/DRAWINGS, 02 41 19.D02 EXISTING SLAB TO REMAIN THE MORE STRINGENT NOTE/SPEC TAKES PRECEDENCE. EXISTING SLAB TO REMAIN 09 22 16.A03 09 22 16.A03 3. HORIZONTAL JOINTS BETWEEN VERTICALLY ORIENTED FLAT STRAP & BACKING PLATE FLAT STRAP & BACKING PLATE GYPSUM BOARD SHEETS SHALL BE BACKED WITH 09 22 16.A11 09 22 16.A11 HORIZONTAL STUDS SPANNING BETWEEN VERTICAL STUDS. SLIP-TYPE HEAD JOINT SLIP-TYPE HEAD JOINT MATCH STUDS IN GAGE, SIZE, & FASTENING. 4. NON-METALLIC ELECTRICAL BOXES SHALL NOT BE INSTALLED 6" 09 29 00.F00 ON OPPOSITE SIDES OF FIRE-RATED PARTITIONS, UNLESS 09 29 00.F00 SOUND ATTENUATION BLANKET CLASSIFIED FOR FIRE-RESISTANCE AS DEFINED BY UL SOUND ATTENUATION BLANKET SECTION "OUTLET BOXES AND FITTINGS CLASSIFIED FOR FIRE 24" MIN 02 41 19.D01 RESISTANCE." BOTH SIDES 09 22 16.A00 6" EXISTING WALL TO REMAIN METAL STUD 5. METALLIC ELECTRICAL BOXES SHALL NOT EXCEED 16 SQ IN WITHIN THE WALL FACE, NOR EXCEED 100 SQ IN AGGREGATE SCHEDULED CEILING, REFER 09 29 00.F00 SURFACE AREA PER 100 SQ FT OF WALL SURFACE. MAINTAIN TO REFLECTED CEILING PLAN 3 1/2" SOUND ATTENUATION BLANKET ON BOTH SIDES MAXIMUM OF 1/8" CLEARANCE BETWEEN BOXES AND GYPSUM 09 29 00.A01 (AT FOCUS & HUDDLE, COORD. W/ AOR) BOARD. GYP BD 5/8" 6. PENETRATIONS SHALL BE SEALED PER APPROPRIATE UL SCHEDULED CEILING, REFER TESTED METHODS, AS DEFINED BY UL SECTION 09 22 16.A00 TO REFLECTED CEILING PLAN "THROUGH-PENETRATION FIRESTOP SYSTEMS." METAL STUD 09 29 00.A01 7. ALL SCREWS SHALL MEET REQUIREMENTS OF ASTM C1002 OR VARIES GYP BD 5/8" ASTM C954. REFER TO PLAN(S) 06 D-T03 02 A-T03 Date Description SCALE: 3" = 1'-0" SCALE: 3" = 1'-0" 2 2020-04-24 DD PRICING 3 2020-06-19 DD REVISED PRICING VARIES REFER TO PLAN(S) 02 41 19.D01 09 29 00.A01 EXISTING WALL TO REMAIN GYP BD 5/8" 09 29 00.A01 09 29 00.F00 GYP BD 5/8" SOUND ATTENUATION BLANKET 09 29 00.F00 09 22 16.A00 SOUND ATTENUATION BLANKET METAL STUD 09 22 16.A00 09 22 16.A01 METAL STUD METAL RUNNER TRACK 09 22 16.A01 09 29 00.G00 METAL RUNNER TRACK CONTINUOUS ACOUS SEALANT 09 29 00.G00 02 41 19.D02 CONTINUOUS ACOUS SEALANT EXISTING SLAB TO REMAIN 02 41 19.D02 EXISTING SLAB TO REMAIN 07 D-B01 03 A-B01 SCALE: 3" = 1'-0" SCALE: 3" = 1'-0" BIM 360://090.0338.100 - UCB Biosciences Workplace Design and Doc/Interiors - 090.0338.000 - _UCB Biosciences.rvt Seal / Signature 09 29 00.A01 GYP BD 5/8" 09 29 00.A01 GYP BD 5/8" NOT FOR 09 22 16.A00 09 22 16.A00 METAL STUD METAL STUD 09 29 00.F00 CONSTRUCTION 02 41 19.D01 SOUND ATTENUATION BLANKET EXISTING WALL OR COLUMN TO REMAIN Project Name UCB BIOSCIENCES VARIES Project Number 090.0338.000 Description PARTITION FRAMING (IN) DETAILS PARTITION FRAMING (IN) DETAILS TYPE ATTEN FIRE TEST STC TYPE ATTEN FIRE TEST STC PARTITION TYPE DETAILS MARK DEPTH SPACING TOP BOT THK RTG ASSEMBLY RTG COMMENTS MARK DEPTH SPACING TOP BOT THK RTG ASSEMBLY RTG COMMENTS D2C 2 1/2" 16" O.C. D-T01 D B01 A3A 3 5/8" 16" O.C. A-T01 A-B01 3-1/2" D3A 3 5/8" 16" O.C. D-T01 D B01 A3B 3 5/8" 16" O.C. A-T03 A-B01 3-1/2" D3B 3 5/8" 16" O.C. D-T02 D B01 A3C 3 5/8" 16" O.C. A-B01 3-1/2" D3C 3 5/8" 16" O.C. D-T02 D B01 A6C 6" 16" O.C. A-T03 A-B01 3-1/2" Scale 3" = 1'-0" 6/19/2020 5:18:01 PM 08 D SERIES PARTITION TYPES SCALE: 3" = 1'-0" 04 A SERIES PARTITION TYPES SCALE: 3" = 1'-0" G5.01 © 2020 Gensler
DOOR SCHEDULE - LEVEL 02 GENERAL NOTES ASSEMBLY LEAF FRAME DETAILS ASSEMBL Y RATING UCB LOCATION ROOM DIMENSIONS FIRE HARDWARE 1. ALL LOCKSETS SHALL BE OPERABLE FROM THE INSIDE ALONG THE PATH OF EGRESS WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE. SPECIAL LOCKING BIOSCIENCES NUMBER TYPE ROOM NAME NUMBER WIDTH HEIGHT THICKNESS MATERIAL FINISH MATERIAL FINISH HEAD JAMB SILL RATING SET REMARKS DEVICES SHALL BE OF AN APPROVED TYPE. ALL 4000 Paramount Pkwy LEVERSETS SHALL HAVE ACCESSIBLE LEVER STYLE. 2000A A 3' - 0" 8' - 0" 0' - 1 3/4" SC ST HM PT 01/G6.02 01/G6.02 21 ACCESS CONTROL Suite 200 & 300 2000B A 3' - 0" 8' - 0" 0' - 1 3/4" SC ST HM PT 01/G6.02 01/G6.02 21 ACCESS CONTROL 2. REQUIRED INTERIOR DOOR OPENING FORCE SHALL Morrisville, NC 27560 2001A G RECEPTION 2001 6' - 0" 9' - 0" 0' - 1 3/4" AL/GL BY MFR AL BY MFR 02/G6.02 02/G6.02 41 ACCESS CONTROL NOT EXCEED 5 LB. 2001B F RECEPTION 2001 3' - 0" 8' - 0" 0' - 1 3/4" AL/GL BY MFR AL BY MFR 03/G6.02 03/G6.02 D5 3. DOORS TO MECHANICAL, ELECTRICAL, & MACHINES 2003 F LG CONF 2003 3' - 0" 8' - 0" 0' - 1 3/4" AL/GL BY MFR AL BY MFR 03/G6.02 03/G6.02 D1 ROOMS SHALL HAVE KNURLED TEXTURE ON INSIDE FACE OF LEVER. 2004 F SM CONF 2004 3' - 0" 8' - 0" 0' - 1 3/4" AL/GL BY MFR AL BY MFR 03/G6.02 03/G6.02 D1 2011 F PIONEER COLLAB 2010 2' - 11" 8' - 0" 4. ELECTRIFIED NON-MAGNETIC LOCKSETS SPECIFIED AS FAIL-SECURE SHALL HAVE A MANUAL KEY OVERRIDE 2012 A WAR ROOM 2012 3' - 0" 8' - 0" 0' - 1 3/4" SC ST AL BY MFR 03/G6.02 03/G6.02 D1 MATCHING BASE BUILDING KEYWAY. 2012A A STORAGE 2012A 3' - 0" 8' - 0" 0' - 1 3/4" SC ST HM PT 01/G6.02 01/G6.02 02 5. ALL HARDWARE TO BE HEAVY DUTY FULL MORTISE... 2014 A SERVER 2014 3' - 0" 8' - 0" 0' - 1 3/4" SC ST HM PT 01/G6.02 01/G6.02 21 ACCESS CONTROL. PROVIDE 18"X18" LOUVER - COORD. 613 Hillsborough St. Tel 919.239.7828 6. ALL WOOD DOORS SHALL BE SOLID CORE. Raleigh, NC 27603 Fax 919.239.7829 W/ MECH 7. COORDINATE KEYING WITH OWNER/TENANT & United States 2015 A RESTROOM 2015 3' - 0" 8' - 0" 0' - 1 3/4" SC ST AL BY MFR 01/G6.02 01/G6.02 04 LANDLORD, IF APPLICABLE. LOCKSETS SHALL HAVE 2016 A STORAGE 2016 3' - 0" 8' - 0" 0' - 1 3/4" SC 04 INTERCHANGEABLE CORES. 2017 A RESTROOM 2017 3' - 0" 8' - 0" 0' - 1 3/4" SC ST AL BY MFR 01/G6.02 01/G6.02 04 8. UNDERCUT INTERIOR DOORS BY 1/4" TYPICALLY; COORDINATE WITH MECHANICAL DRAWINGS FOR 2018 A WELLNESS 2018 3' - 0" 8' - 0" 0' - 1 3/4" SC ST AL BY MFR 01/G6.02 01/G6.02 04 LOCATIONS FOR HIGHER UNDERCUTS, IF ANY. 2019 A WELLNESS 2019 3' - 0" 8' - 0" 0' - 1 3/4" SC 9. REINFORCED HOLLOW METAL FRAMES ARE REQUIRED 2020 A STORAGE 2020 3' - 0" 8' - 0" 0' - 1 3/4" SC FOR HEAVY DUTY HINGES. 10. ALL BUTT HINGED LEAFS OVER 3'-0" WIDE TO HAVE 5" X 2021A F PIONEER COLLAB 2010 3' - 0" 8' - 0" 4 1/2" HINGES. 2021AA B 4' - 2 1/4" 8' - 0" 0' - 1 3/4" SC ST 10 DOOR AND HARDWARE BY OPERABLE PARTITION MFR. 11. EXTERIOR DOOR HINGES SHALL BE NON-FERROUS AND 2021B F PIONEER COLLAB 2010 3' - 0" 8' - 0" HAVE NON-REMOVABLE PINS. 2022 A FURN STORAGE 2022 3' - 0" 8' - 0" 0' - 1 3/4" SC 12. COORDINATE SECURITY REQUIREMENTS & PROGRAMMING WITH OWNER/TENANT, SECURITY 2023 F PHONE 2023 2' - 8" 8' - 0" DESIGNER, & SECURITY VENDOR PRIOR TO 2024 F PHONE 2024 2' - 9" 8' - 0" FABRICATION OF DOORS & FRAMES. PROVIDE CONDUIT & OTHER ROUGH-IN FOR ELECTRIFIED 2030A F LIBRARY VESTIBULE 2030 3' - 1" 8' - 0" HARDWARE. 2030B A LIBRARY VESTIBULE 2030 3' - 0" 8' - 0" 0' - 1 3/4" SC 13. CONFIRM LOCKSET TYPE AND MANUFACTURER WITH 2031 F LIBRARY 2040 3' - 0" 8' - 0" LANDLORD (IF APPLICABLE) TO COORDINATE WITH 2032 F LIBRARY 2040 3' - 0" 8' - 0" BUILDING STANDARDS. 14. DOOR HARDWARE FINISH SHALL BE BLACK, UNLESS 2041 F BUBBLE 2041 3' - 1" 8' - 0" NOTED OTHERWISE. 2043 F BUBBLE 2043 3' - 1" 8' - 0" 15. WHERE EXISTING DOOR, FRAMES, AND/OR HARDWARE 2045 F BUBBLE 2045 3' - 3 9/16" 8' - 0" ARE TO BE RE-USED, VERIFY EXISTING ELEMENTS ARE IN WORKING ORDER & COMPATIBLE WITH SECURITY & 2047 F BUBBLE 2047 3' - 1" 8' - 0" FUNCTIONAL REQUIREMENTS. CLEAN EXISTING 2051 F BUBBLE 2051 3' - 1" 8' - 0" DOORS, FRAMES, & HARDWARE. 2052 F LIBRARY 2060 3' - 0" 8' - 0" 2053 F BUBBLE 2053 3' - 2 5/32" 8' - 0" 16. ALL EXISTING-TO-REMAIN DOORS SHALL RECEIVE NEW HARDWARE. EXISTING DOORS SHALL BE PATCHED & 2054 F LIBRARY 2060 2' - 11 7/8" 8' - 0" REPAIRED TO RECEIVE NEW HARDWARE. 2055 F COLLAB 2050 3' - 3 7/32" 8' - 0" 2061 A LIBRARY 2060 2' - 11" 8' - 0" 0' - 1 3/4" SC ST AL BY MFR 03/G6.02 03/G6.02 D1 2063 A LIBRARY 2060 2' - 9 8' - 0" 0' - 1 3/4" SC ST AL BY MFR 03/G6.02 03/G6.02 D1 25/32" 2065 A LIBRARY 2060 2' - 10 8' - 0" 0' - 1 3/4" SC ST AL BY MFR 03/G6.02 03/G6.02 D1 13/32" 2067 A LIBRARY 2060 2' - 11" 8' - 0" 0' - 1 3/4" SC ST AL BY MFR 03/G6.02 03/G6.02 D1 2069 A LIBRARY 2060 2' - 11" 8' - 0" 0' - 1 3/4" SC D1 S201 A 3' - 0" 8' - 0" 0' - 1 3/4" SC S202 A 3' - 0" 8' - 0" 0' - 1 3/4" SC ABBREVIATION DOOR SCHEDULE - LEVEL 03 AL ALUMINUM ASSEMBL GL GLAZING ASSEMBLY LEAF FRAME DETAILS Y RATING HM HOLLOW METAL LOCATION DIMENSIONS MFR MANUFACTURER ROOM FIRE HARDWARE PT PAINTED Date Description NUMBER TYPE ROOM NAME NUMBER WIDTH HEIGHT THICKNESS MATERIAL FINISH MATERIAL FINISH HEAD JAMB SILL RATING SET REMARKS SC SOLID CORE 2 2020-04-24 DD PRICING 3000A G WORK CAFE 3001 6' - 0" 9' - 0" 0' - 1 3/4" AL/GL BY MFR AL BY MFR 02/G6.02 41 ACCESS CONTROL ST STAINED VENEER 3 2020-06-19 DD REVISED PRICING 3000B G ELEVATOR LOBBY 3000 6' - 0" 9' - 0" 0' - 1 3/4" AL/GL BY MFR AL BY MFR 02/G6.02 41 ACCESS CONTROL 3003 A STORAGE 3003 3' - 0" 8' - 0" 0' - 1 3/4" SC ST AL BY MFR 01/G6.02 01/G6.02 21 3004 A SERVER 3004 3' - 0" 8' - 0" 0' - 1 3/4" SC ST AL BY MFR 01/G6.02 01/G6.02 21 ACCESS CONTROL 3005 A IT WORKROOM 3005 3' - 0" 8' - 0" 0' - 1 3/4" SC ST AL BY MFR 01/G6.02 01/G6.02 21 ACCESS CONTROL 3006 F HALO CONFERENCE 3006 3' - 0" 8' - 0" ST AL BY MFR 03/G6.02 03/G6.02 D1 3007 A STORAGE 3007 3' - 0" 8' - 0" 0' - 1 3/4" SC 3008 F PHONE 3008 3' - 0" 8' - 0" ST AL BY MFR 03/G6.02 03/G6.02 D1 3009 F PHONE 3009 3' - 0" 8' - 0" ST AL BY MFR 03/G6.02 03/G6.02 D1 3011 F TREADMILL 3011 3' - 0" 8' - 0" D1 3012 F BUBBLE 3012 3' - 0" 8' - 0" ST AL BY MFR 03/G6.02 03/G6.02 D1 3013 F BUBBLE 3013 3' - 0" 8' - 0" ST AL BY MFR 03/G6.02 03/G6.02 D1 3014 F HUDDLE 3014 3' - 0" 8' - 0" ST AL BY MFR 03/G6.02 03/G6.02 D1 3021 F TREADMILL 3021 3' - 1 1/2" 8' - 0" ST AL BY MFR 03/G6.02 03/G6.02 D1 3022 F BUBBLE 3022 2' - 10 1/2" 8' - 0" ST AL BY MFR 03/G6.02 03/G6.02 D1 3023 F BUBBLE 3023 3' - 0" 8' - 0" ST AL BY MFR 03/G6.02 03/G6.02 D1 3024 F HUDDLE 3024 3' - 0" 8' - 0" ST AL BY MFR 03/G6.02 03/G6.02 D1 3025 F MD CONF 3025 3' - 0" 8' - 0" ST AL BY MFR 03/G6.02 03/G6.02 D1 3026 F MD CONF 3026 3' - 0" 8' - 0" ST AL BY MFR 03/G6.02 03/G6.02 D1 3031 F PHONE 3031 3' - 0" 8' - 0" ST AL BY MFR 03/G6.02 03/G6.02 D1 3032 F BUBBLE 3032 3' - 0 3/4" 8' - 0" ST AL BY MFR 03/G6.02 03/G6.02 D1 3033 F BUBBLE 3033 3' - 0 5/8" 8' - 0" ST AL BY MFR 03/G6.02 03/G6.02 D1 3034 F HUDDLE 3034 3' - 0 1/2" 8' - 0" ST AL BY MFR 03/G6.02 03/G6.02 D1 3035 F SM CONF 3035 3' - 0" 8' - 0" ST AL BY MFR 03/G6.02 03/G6.02 D1 3036 F SM CONF 3036 3' - 0" 8' - 0" ST AL BY MFR 03/G6.02 03/G6.02 D1 3041 F PHONE 3041 3' - 0" 8' - 0" ST AL BY MFR 03/G6.02 03/G6.02 D1 3042 F BUBBLE 3042 3' - 0 3/8" 8' - 0" ST AL BY MFR 03/G6.02 03/G6.02 D1 3043 F BUBBLE 3043 3' - 0 1/4" 8' - 0" ST AL BY MFR 03/G6.02 03/G6.02 D1 3044 F HUDDLE 3044 3' - 0 1/8" 8' - 0" ST AL BY MFR 03/G6.02 03/G6.02 D1 3048 A STORAGE 3048 3' - 0" 8' - 0" 0' - 1 3/4" SC ST AL BY MFR 01/G6.02 01/G6.02 04 BIM 360://090.0338.100 - UCB Biosciences Workplace Design and Doc/Interiors - 090.0338.000 - _UCB Biosciences.rvt 3051 F CREATIVE WORK 3050 3' - 0" 8' - 0" ST AL BY MFR 03/G6.02 03/G6.02 D1 3052 E BUBBLE 3052 3' - 2" 8' - 0" 0' - 1 3/4" AL/GL BY MFR AL BY MFR 04/G6.02 D3 3053 E BUBBLE 3053 3' - 0 8' - 0" 0' - 1 3/4" AL/GL BY MFR AL BY MFR 04/G6.02 D3 Seal / Signature 23/32" 3054 E BUBBLE 3054 2' - 11 8' - 0" 0' - 1 3/4" AL/GL BY MFR AL BY MFR 04/G6.02 D3 7/16" 3061 3062 F F TREADMILL OPEN OFFICE 3061 3060 3' - 0" 3' - 0" 8' - 0" 8' - 0" ST ST AL AL BY MFR BY MFR 03/G6.02 03/G6.02 03/G6.02 03/G6.02 D1 D1 NOT FOR 3063 3064 F F OPEN OFFICE OPEN OFFICE 3060 3060 3' - 0" 3' - 0" 8' - 0" 8' - 0" ST ST AL AL BY MFR BY MFR 03/G6.02 03/G6.02 03/G6.02 03/G6.02 D1 D1 CONSTRUCTION 3066 F PHONE 3066 3' - 0" 8' - 0" D1 3067 F PHONE 3067 3' - 0" 8' - 0" D1 Project Name 3071 F TREADMILL 3071 3' - 0" 8' - 0" ST AL BY MFR 03/G6.02 03/G6.02 D1 3072 F OPEN OFFICE 3070 3' - 0" 8' - 0" ST AL BY MFR 03/G6.02 03/G6.02 D1 UCB BIOSCIENCES 3073 F OPEN OFFICE 3070 3' - 0" 8' - 0" ST AL BY MFR 03/G6.02 03/G6.02 D1 3074 F OPEN OFFICE 3070 3' - 0" 8' - 0" ST AL BY MFR 03/G6.02 03/G6.02 D1 3075 F MD CONF 3075 3' - 0" 8' - 0" ST AL BY MFR 03/G6.02 D1 Project Number 3076 F LG CONF 3076 3' - 0" 8' - 0" ST AL BY MFR 03/G6.02 D1 3081 F PHONE 3081 3' - 0" 8' - 0" ST AL BY MFR 03/G6.02 03/G6.02 D1 090.0338.000 3082 F BUBBLE 3082 3' - 0" 8' - 0" ST AL BY MFR 03/G6.02 03/G6.02 D1 Description 3083 F BUBBLE 3083 3' - 0" 8' - 0" D1 DOOR ELEVATIONS AND DOOR 3084 F HUDDLE 3084 3' - 0" 8' - 0" ST AL BY MFR 03/G6.02 03/G6.02 D1 SCHEDULE 3085 F SM CONF 3085 3' - 0" 8' - 0" ST AL BY MFR 03/G6.02 D1 3091 F PHONE 3091 3' - 0" 8' - 0" ST AL BY MFR 03/G6.02 03/G6.02 D1 3092 F BUBBLE 3092 3' - 0" 8' - 0" ST AL BY MFR 03/G6.02 03/G6.02 D1 Scale 3093 F BUBBLE 3093 3' - 0" 8' - 0" D1 3094 F HUDDLE 3094 3' - 0" 8' - 0" ST AL BY MFR 03/G6.02 03/G6.02 D1 3096 F HR SUITE 3096 3' - 0" 8' - 0" D1 3097A F HUDDLE 3097 3' - 0" 8' - 0" D1 6/19/2020 5:18:04 PM 3097B A HUDDLE 3097 3' - 0" 8' - 0" 0' - 1 3/4" SC S301 A STAIR S301 3' - 0" 8' - 0" 0' - 1 3/4" SC EXIST HM PT 45 MIN EXISTING DOOR/FRAME, ACCESS CONTROL, COORD. W/ LANDLORD SECURITY G6.01 S302 A STAIR S302 3' - 0" 8' - 0" 0' - 1 3/4" SC EXIST HM PT 45 MIN EXISTING DOOR/FRAME, ACCESS CONTROL, COORD. W/ LANDLORD SECURITY © 2020 Gensler
41 - SINGLE LEAF - GLASS, MAGNETIC 01 - SINGLE LEAF - PASSAGE FUNCTION UCB 2 SECURING DEVICES 36" BAR PULL X HANGING DEVICES BUTT HINGES, BALL BEARING SCHEDULED PARTITION 1 SECURING DEVICES 1 CLOSERS DEVICES 1 MISC DEVICES ELECTRO-MAGNETIC LOCK OVERHEAD CONCEALED CLOSER WITH INTEGRAL PIVOT AND MATCHING BOTTOM PIVOT REQUEST TO EXIT, MOTION SENSOR 1 1 1 SECURING DEVICES CLOSERS DEVICES STOPS AND HOLDERS MORTISE LOCKSET, PASSAGE FUNCTION SURFACE MOUNTED OVERHEAD CLOSER (NON PUBLIC SIDE) FLOOR STOP BIOSCIENCES 1 MISC DEVICES PUSH TO EXIT BUTTON - MISC DEVICES SILENCERS GREY 4000 Paramount Pkwy NOTE: CARD READER AND DOOR CONTACT BY OTHERS. TIE TO BUILDING FIRE ALARM SYSTEM. DOOR TO ALLOW FREE Suite 200 & 300 6" TYP, UNO JAMB: ADJACENT WALL, EGRESS AT ALL TIMES. WHERE APPLICABLE Morrisville, NC 27560 02 - SINGLE LEAF - STORAGE FUNCTION 1/2" TYP SEALANT AT JAMB, BOTH SIDES 41 - DOUBLE LEAF - GLASS, MAGNETIC X HANGING DEVICES BUTT HINGES, BALL BEARING HEAD: CEILING, WHERE APPLICABLE 1 SECURING DEVICES MORTISE LOCKSET, STORAGE FUNCTION 2" 4 SECURING DEVICES 36" BAR PULL 1 CLOSERS DEVICES SURFACE MOUNTED OVERHEAD CLOSER (NON PUBLIC SIDE) HM FRAME 2 SECURING DEVICES ELECTRO-MAGNETIC LOCK 1 STOPS AND HOLDERS FLOOR STOP 2 CLOSERS DEVICES OVERHEAD CONCEALED CLOSER WITH INTEGRAL PIVOT AND MATCHING BOTTOM PIVOT - MISC DEVICES SILENCERS GREY 5/8" DOOR 1 MISC DEVICES REQUEST TO EXIT, MOTION SENSOR 1 MISC DEVICES PUSH TO EXIT BUTTON 03 - SINGLE LEAF - OFFICE/ENTRY FUNCTION NOTE: CARD READER AND DOOR CONTACT BY OTHERS. TIE TO BUILDING FIRE ALARM SYSTEM. DOOR TO ALLOW FREE X HANGING DEVICES BUTT HINGES, BALL BEARING 613 Hillsborough St. Tel 919.239.7828 EGRESS AT ALL TIMES. 1 SECURING DEVICES MORTISE LOCKSET, OFFICE/ENTRY FUNCTION Raleigh, NC 27603 Fax 919.239.7829 1 CLOSERS DEVICES SURFACE MOUNTED OVERHEAD CLOSER (NON PUBLIC SIDE) United States 1 STOPS AND HOLDERS FLOOR STOP - MISC DEVICES SILENCERS GREY 04 - SINGLE LEAF - PRIVACY FUNCTION X HANGING DEVICES BUTT HINGES, BALL BEARING D1 - DEMOUNTABLE SINGLE LEAF - PASSAGE FUNCTION 1 SECURING DEVICES MORTISE LOCKSET, PRIVACY FUNCTION WITH OCCUPANCY INDICATOR 01 DOOR DETAIL - HM HEAD/JAMB ALL HARDWARE PROVIDED BY DEMOUNTABLE PROVIDER, UNLESS NOTED OTHERWISE 1 1 CLOSERS DEVICES STOPS AND HOLDERS SURFACE MOUNTED OVERHEAD CLOSER (NON PUBLIC SIDE) FLOOR STOP SCALE: 3" = 1'-0" X HANGING DEVICES - MISC DEVICES SILENCERS GREY 2 SECURING DEVICES 36" BAR PULL 1 CLOSERS DEVICES CLOSER 1 STOPS AND HOLDERS FLOOR STOP & ANGLE STOP, BY DOOR HARDWARE VENDOR - MISC DEVICES SILENCERS BLACK SCHEDULED PARTITION D2 - DEMOUNTABLE SINGLE LEAF - PASSAGE FUNCTION HEAD: METAL STUD BOX HEADER ALL HARDWARE PROVIDED BY THE DEMOUNTABLE PROVIDER, UNLESS NOTED OTHERWISE 10 - DOUBLE LEAF - CLOSET X HANGING DEVICES JAMB: ADJACENT WALL, X HANGING DEVICES BUTT HINGES, BALL BEARING 6" TYP, UNO 1 SECURING DEVICES PANIC BAR, 36" BAR PULL WHERE APPLICABLE 1 CLOSERS DEVICES CLOSER 2 SECURING DEVICES DUMMY LEVERS (OUTSIDE CLOSET) 1 STOPS AND HOLDERS FLOOR STOP & ANGLE STOP, BY DOOR HARDWARE VENDOR 2 SECURING DEVICES ROLLER LATCH WITH INTEGRAL ANGLE STOP SCHEDULED PARTITION 1 CLOSERS DEVICES SURFACE MOUNTED OVERHEAD CLOSER (NON PUBLIC SIDE) - MISC DEVICES SILENCERS BLACK 2 STOPS AND HOLDERS OVERHEAD STOP HEAD: CEILING, WHERE APPLICABLE 1 1/2" D3 - DEMOUNTABLE SLIDING SINGLE LEAF - PASSAGE FUNCTION 11 - DOUBLE LEAF - PASSAGE ALUMINUM FRAME ALL HARDWARE PROVIDED BY DEMOUNTABLE PROVIDER, UNLESS NOTED OTHERWISE X HANGING DEVICES BUTT HINGES, BALL BEARING X HANGING DEVICES 2 SECURING DEVICES MORTISE LOCKSET, PASSAGE FUNCTION (ACTIVE LEAF) 2 SECURING DEVICES 36" BAR PULL 1 SECURING DEVICES TOP & BOTTOM MANUAL FLUSH BOLTS (INACTIVE LEAF) DOOR OR GLASS 1 STOPS AND HOLDERS INTEGRAL SLIDER TRACK 2 SECURING DEVICES ROLLER LATCH WITH INTEGRAL ANGLE STOP - MISC DEVICES BRUSH GASKETS BLACK 1 CLOSERS DEVICES SURFACE MOUNTED OVERHEAD CLOSER (ACTIVE LEAF, NON PUBLIC SIDE) 2 STOPS AND HOLDERS FLOOR STOP D4 - DEMOUNTABLE SINGLE LEAF - PASSAGE FUNCTION 1 MISC DEVICES DUSTPROOF STRIKE ALL HARDWARE PROVIDED BY DEMOUNTABLE PROVIDER, UNLESS NOTED OTHERWISE 12 - DOUBLE LEAF - EXIT DEVICE - BLANK / ACTIVE FUNCTION X HANGING DEVICES 2 SECURING DEVICES 36" BAR PULL X HANGING DEVICES BUTT HINGES, BALL BEARING 1 CLOSERS DEVICES CLOSER 2 SECURING DEVICES RIM EXIT DEVICE WITH CONCEALED VERTICAL TOP & BOTTOM RODS, BLANK/ACTIVE FUNCTION 1 STOPS AND HOLDERS ANGLE STOP, BY DOOR HARDWARE VENDOR 2 CLOSERS DEVICES SURFACE MOUNTED OVERHEAD CLOSER (NON PUBLIC SIDE) - MISC DEVICES SILENCERS BLACK 2 STOPS AND HOLDERS FLOOR STOP 02 DOOR/GLASS DETAIL - ALUM HEAD/JAMB 2 MISC DEVICES DUSTPROOF STRIKE SCALE: 3" = 1'-0" D5 - DEMOUNTABLE SINGLE LEAF - MAGNETIC ALL HARDWARE PROVIDED BY DEMOUNTABLE PROVIDER, UNLESS NOTED OTHERWISE X HANGING DEVICES 2 SECURING DEVICES 36" BAR PULL 1 CLOSERS DEVICES CLOSER SCHEDULED PARTITION 1 STOPS AND HOLDERS ANGLE STOP, BY DOOR HARDWARE VENDOR - MISC DEVICES SILENCERS BLACK 21 - SINGLE LEAF - ACCESS CONTROL, ELECTRONIC 1 SECURING DEVICES ELECTRO-MAGNETIC LOCK, BY SECURITY VENDOR X HANGING DEVICES BUTT HINGES, BALL BEARING 1 MISC DEVICES REQUEST TO EXIT, MOTION SENSOR 1 HANGING DEVICES ELECTRIC THROUGH-WIRE HINGE 1 MISC DEVICES PUSH TO EXIT BUTTON 1 SECURING DEVICES MORTISE LOCKSET, ELECTRONIC Date Description CEILING, WHERE APPLICABLE NOTE: CARD READER AND DOOR CONTACT BY OTHERS. TIE TO BUILDING FIRE ALARM SYSTEM. DOOR TO ALLOW FREE 1 CLOSERS DEVICES SURFACE MOUNTED OVERHEAD CLOSER (NON PUBLIC SIDE) EGRESS AT ALL TIMES. COORDINATE WITH SECURITY VENDOR. 1 STOPS AND HOLDERS FLOOR STOP 2 2020-04-24 DD PRICING - MISC DEVICES SILENCERS GREY 3 2020-06-19 DD REVISED PRICING METAL STUD BOX HEADER NOTE: CARD READER AND DOOR CONTACT BY OTHERS. TIE TO BUILDING FIRE ALARM SYSTEM. DOOR TO ALLOW FREE EGRESS AT ALL TIMES. DEMOUNTABLE FRAME AND DOOR EQ EQ 31 - DOUBLE LEAF - ACCESS CONTROL, MAGNETIC X HANGING DEVICES BUTT HINGES, BALL BEARING 1 SECURING DEVICES MORTISE LOCKSET, DUMMY (ACTIVE LEAF) 1 SECURING DEVICES MANUAL FLUSH BOLT (INACTIVE LEAF) 03 DEMOUNTABLE HEAD - JAMB SIMILAR 1 2 SECURIING DEVICES CLOSERS DEVICES ELECTRO-MAGNETIC LOCK (ACTIVE LEAF) CONCEALED OVERHEAD CLOSER SCALE: 3" = 1'-0" 1 MISC DEVICES REQUEST TO EXIT, MOTION SENSOR 1 MISC DEVICE PUSH TO EXIT BUTTON NOTE: CARD READER AND DOOR CONTACT BY OTHERS. TIE TO BUILDING FIRE ALARM SYSTEM. MAGLOCK MUST BE FAIL-SAFE. 32 - DOUBLE LEAF - ACCESS CONTROL, MAGNETIC X HANGING DEVICES BUTT HINGES, BALL BEARING 4 SECURING DEVICES 36" BAR PULLS SCHEDULED PARTITION 2 SECURIING DEVICES ELECTRO-MAGNETIC LOCK 2 CLOSERS DEVICES OVERHEAD CONCEALED CLOSER METAL STUD BOX HEADER 1 MISC DEVICES REQUEST TO EXIT, MOTION SENSOR 1 MISC DEVICE PUSH TO EXIT BUTTON NOTE: CARD READER AND DOOR CONTACT BY OTHERS. TIE TO BUILDING FIRE ALARM SYSTEM. MAGLOCK MUST BE FAIL-SAFE. SCHEDULED CEILING DEMOUNTABLE FRAME 33 - DOUBLE LEAF - ACCESS CONTROL, ELECTRONIC X HANGING DEVICES BUTT HINGES, BALL BEARING SLIDING DOOR 1 HANGING DEVICES ELECTRIC THROUGH-WIRE HINGE 2 SECURING DEVICES MORTISE LOCKSET, ELECTRONIC (ACTIVE LEAF) BIM 360://090.0338.100 - UCB Biosciences Workplace Design and Doc/Interiors - 090.0338.000 - _UCB Biosciences.rvt 1 SECURING DEVICES MANUAL FLUSH BOLT (INACTIVE LEAF) OFFICE OR OPEN OFFICE 1 SECURING DEVICES DUSTPROOF STRIKE CONFERENCE OR CORRIDOR 2 CLOSERS DEVICES CONCEALED OVERHEAD CLOSER - MISC DEVICES SILENCERS GREY Seal / Signature ROOM 2 MISC DEVICES MAGNETIC HOLD OPEN DEVICE NOTE: CARD READER AND DOOR CONTACT BY OTHERS. TIE TO BUILDING FIRE ALARM SYSTEM. DOOR TO BE HELD OPEN DURING BUSINESS HOURS, CLOSED AFTER HOURS. AFTER HOURS, DOOR TO BE OPENED BY CARD READER. NOT FOR 04 DOOR DETAIL - DEMOUNTABLE SLIDING HEAD SCALE: 3" = 1'-0" CONSTRUCTION AS SCHEDULED AS SCHEDULED AS SCHEDULED AS SCHEDULED AS SCHEDULED Project Name UCB BIOSCIENCES AS AS AS Project Number SCHEDULED SCHEDULED SCHEDULED DOOR FRAME 090.0338.000 AS SCHEDULED AS SCHEDULED AS SCHEDULED AS SCHEDULED AS SCHEDULED AS SCHEDULED DOOR LEAF AS Description SCHEDULED DOOR, FRAME AND HARDWARE 2' - 10" AFF MIN 2' - 10" AFF MIN 2' - 10" AFF MIN SCHEDULES LOUVER AS SCHEDULED Scale As indicated TYPE G TYPE F TYPE E TYPE B TYPE A DOUBLE FLUSH GLASS DOOR SINGLE FLUSH GLASS DOOR SINGLE FLUSH SLIDING GLASS DOOR DOUBLE FLUSH DOOR SINGLE FLUSH DOOR 6/19/2020 5:18:15 PM W/ RAILS & STILES W/ RAILS & STILES AS SCHEDULED AS SCHEDULED DOOR TYPES G6.02 05 SCALE: 3/8" = 1'-0" © 2020 Gensler