SPEL Ecoceptor - spel.com.au
←
→
Page content transcription
If your browser does not render page correctly, please read the page content below
APPLICATIONS
• Shopping precincts
• Commercial zones
• Recreational grounds
• Light industrial areas
• Beaches and parks
BENEFITS
The SPEL Ecoceptor is delivered to site fully assembled
saving on installation time and crane costs. The SPEL
Ecoceptor fibreglass GPT can be installed in all types
of trafficable zones, including vehicular truck (Class D).
(Subject to the installation of an engineered cast in situ
concrete slab.)
The cylindrical shape of the SPEL Ecoceptor with
The SPEL Ecoceptor is a hydrodynamic in-line Gross its sloped cone-configured base ensures sediment
Pollutant Trap (GPT) that has a unique treatment action accretes at the centre of the Ecoceptor’s base
producing low velocity conditions (and extended dwell facilitating easy and simple cleaning.
times to separate pollutants), resulting in discharge
water quality outcomes complying to statutory The poly/fibreglass construction ensures that oil and
guidelines across Australia. grease are removed without sticking to the sides of the
internal walls.
It separates and captures sediments, silt, total
suspended solids, and oil and grease. Oil & grease rise Flow rates on standard units of up to 2800 LPS and
to the “oil-capture” zone of the treatment chamber and can fit pipe sizes from 150mm to 1800mm (other sizes
are contained in all flow events. available on request).
Areas with a high fraction of impervious
surfaces,including car parks, ports, streetscapes,
roads, subdivisions and industrial estates that require
stormwater treatment are ideal for the SPEL Ecoceptor.
MUSIC node is available on request.
The one-piece, self-contained fibreglass construction,
is lightweight and yet robust in strength making it
simple and cost-effective when performing installations.
2 SPEL EcoceptorCLASS 3 FEATURES
ECOCEPTOR
“Class 3 Ecoceptor” act as gross pollutant traps and at • Unique stainless steel V screen collects gross
the same time improves stormwater quality. pollutants
• Easy access to all parts for desludging and oil
They separate and capture gross pollutants, sediments
removal
and silt. Light liquids (petroleum hydrocarbons) rise to
the top of the lower chamber while sludge settles on • Can handle high flows
the bottom.
• By-pass operation when very heavy rain persists,
preventing “back up’
• Units are factory-made to suit any application
• Fibreglass construction
• Minimum on-site labour costs
• Flow rates up to 2800 LPS
Options:
• Trafficable lid types
• Different pipe configurations and sizes
• Manhole risers
• Larger tanks
Tested Treatment Efficiencies*
Pollutant Efficiency
Gross Pollutants (GP) 95%
Gross Pollutant Traps
Total Suspended Solids (TSS) 71%
“Class 3 Stormceptors” act as gross pollutant traps and at the same time improve stormwater quality.
Total Phosphorus (TP) 69%
They separate and capture gross pollutants, sediments and silt.
Light liquids (petroleum hydrocarbons) rise to the top of the lower chamber
Total while
Nitrogen (TN)sludge settles on 47%
the bottom.
Petroleum Hydrocarbon 93%
Features:
• Unique “V-screen”
*Contact collects
Spel to confirm gross
approved pollutants
performance for the project LGA
Organic/particulate component of the nutrient only.
• Easy access to all parts for desludging and oil removal
• Can handle high flows
• By pass operation when very heavy rain persists,
APPLICATIONS
preventing “back up’
• Units factory-made to suit any application
• Fibreglass construction
• Minimum on-site labour costs
• Flow rates up to 1400 LPS
Options:
• Trafficable
• Car lid types
parks
• Different pipe configurations and sizes
• • risers
Manhole Industrial estates
• Larger tanks
• Town houses
Suitable for:
• Car parks
• Industrial estates
• Town houses
spel.com.au 3
Class 3 StormceptorDRAWINGS
1500 Series
6 5 4 3 2 1
ACCESS MANHOLE
600 x 600 - CLASS 'D' LID
D D
INLET Ø450 OUTLET Ø450
PVC PIPE PVC PIPE
PLAN VIEW
C C
I.D. 1520
FSL. 196.196
E:\Vault Working Folder\Designs\SPEL\PRODUCTS\ECOCEPTOR\1500 Series\E.240-153737.PVC\PROJECT\LAVINGTON FIRE STATION\SP21-EC26330-P.idw
100
150
800
800
700
IL. 195.396
OVERALL HEIGHT 2050
ISOMETRIC VIEW
B B
INLET & OUTLET 1250
1250
ELEVATION VIEW END VIEW
OUTLET
TOLERANCE: All Dimensions to Closest 10 mm & +/- 30 mm ALL INTERCONNECTING PIPEWORK, PITS AND ASSOCIATED DRAINAGE BY OTHERS
CLIENT:
CONFIDENTIAL - The drawings must not be disclosed to any third
Drawn Date PROJECT :
parties without written permission from SPEL STORMWATER .
Unauthorised disclosure may result in prosecution. J.MAKIN 17/06/2021
© SPEL STORMWATER - This drawing is the property of SPEL
STORMWATER ABN: 83 151 832 629 and is subject to return on Check Date TITLE
A demand. It is submitted for the use only in connection with the
proposal and contracts of SPEL STORMWATER with the expressed
A
conditions that it is not to be reproduced or copied in any form. Verified Date SPEL ECOCEPTOR
This data must only be used in accordance with our standard 1500 SERIES - E.240/153737.PVC
terms and conditions.
© Copyright Approved Date
SPEL STORMWATER accepts no responsibility for any loss or
damage resulting from any person acting on this information. SCALE SIZE SHEET REV
The details and dimensions contained in this document may change, A3 1 1
N.T.S
please check with SPEL STORMWATER for confirmation of current Request No.
1 INITIAL RELEASE J.MAKIN 19/08/2020 CUSTOMER CODE : DWG No.
REV DESCRIPTION BY DATE CHECKED BY
specifications.
SP21-EC26330-P
6 5 4 3 2 1
2000 Series
6 5 4 3 2 1
REVISION HISTORY
REV DESCRIPTION DESIGNER CREATION DATE CHECKED BY
2040
1 INITIAL RELEASE J.MAKIN 13/03/2018
D D
INLET Ø600 OUTLET Ø600
RCP COLLAR RCP COLLAR
ACCESS MANHOLE
600 x 600
C PLAN VIEW C
O.D. 1690
I.D. 1520
100
E:\Vault Working Folder\Designs\SPEL\PRODUCTS\ECOCEPTOR\2000 Series\E.240-203737\PROJECT\TONGARIRO PRISON\SP18-EC23000-P.idw
O.I.L. 900
I.I.L. 900
OVERALL HEIGHT 2300
ISOMETRIC VIEW
B B
ELEVATION VIEW SIDE VIEW
TOLERANCE: ALL DIMENSIONS 10mm UNLESS OTHERWISE STATED.
CLIENT: DISTRIBUTOR : CONFIDENTIAL - The drawings must not be disclosed to any third Drawn Date PROJECT :
parties without written permission from SPEL Environmental Sydney.
Unauthorised disclosure may result in prosecution. J.MAKIN 13/08/2018
© SPEL Environmental - This drawing is the property of SPEL
Check Date
A Environmental ABN: 83 151 832 629 and is subject to return on
demand. It is submitted for the use only in connection with the TITLE
SPEL ECOCEPTOR A
proposal and contracts of SPEL Environmental with the expressed
conditions that it is not to be reproduced or copied in any form.
Verified Date 2000 SERIES - E240/203737.RCP
This data must only be used in accordance with our standard GENERAL ARRANGEMENT
terms and conditions.
© Copyright Approved Date
SPEL Environmental accepts no responsibility for any loss or SCALE SIZE SHEET REV
damage resulting from any person acting on this information. N.T.S A3 1
Request No. 1
The details and dimensions contained in this document may change,
please check with SPEL Environmental for confirmation of current RN2218 CUSTOMER CODE : DWG No.
specifications. SP18-EC23000-P
6 5 4 3 2 1
4 SPEL EcoceptorDRAWINGS
4000 Series
6 5 4 3 2 1
REVISION HISTORY
REV DESCRIPTION DESIGNER DATE APPROVED
1 INITIAL RELEASE J.MAKIN 15/07/2021
D D
INLET - 825
RCP PIPE
OUTLET - 825
RCP PIPE
ACCESS MANHOLE
600 x 900 - COVERD
PLAN VIEW CLASS 'D' LID
2310
C 100 C
OIL. 1000
IIL. 1000
100
E:\Vault Working Folder\Designs\SPEL\PRODUCTS\ECOCEPTOR\4000 Series\E.450-404545\PROJECT\ARDEN ANGLICAN SCHOOL\SP19-EC12470-P.idw
900
TANK HEIGHT 3100
TANK HEIGHT 3000
ISOMETRIC VIEW
2100
B B
ELEVATION VIEW ID. 1800
SIDE VIEW
TOLERANCE: ALL DIMENSIONS 10mm UNLESS OTHERWISE STATED.
CLIENT: DISTRIBUTOR : CONFIDENTIAL - The drawings must not be disclosed to any third Drawn Date PROJECT :
parties without written permission from SPEL Environmental Sydney.
Unauthorised disclosure may result in prosecution. J.MAKIN 15/07/2019
© SPEL Environmental - This drawing is the property of SPEL
Environmental ABN: 83 151 832 629 and is subject to return on Check Date
A demand. It is submitted for the use only in connection with the TITLE A
proposal and contracts of SPEL Environmental with the expressed ECOCEPTOR - 4000 SER.
Verified Date
conditions that it is not to be reproduced or copied in any form. E.320/403737.PVC
This data must only be used in accordance with our standard
terms and conditions. GENERAL ARRANGEMENT
© Copyright Approved Date
SPEL Environmental accepts no responsibility for any loss or SCALE SIZE REV
N.T.S SHEET
damage resulting from any person acting on this information.
Request No. A3 1 1
The details and dimensions contained in this document may change,
please check with SPEL Environmental for confirmation of current RN2600 CUSTOMER CODE : DWG No.
specifications. SP19-EC12470-P
6 5 4 3 2 1
6000 Series
6 5 4 3 2 1
REVISION HISTORY
2720 REV DESCRIPTION DESIGNER DATE CHECKED BY
1 INITIAL RELEASE J.MAKIN 11/01/2016
ACCESS MANHOLE
600 x 900
D D
1050 INLET 1050 OUTLET
RCP PIPE RCP COLLAR
PLAN VIEW
O.D. 2300
C I.D. 2200 C
E:\Vault Working Folder\Designs\SPEL\PRODUCTS\ECOCEPTOR\6000 Series\ECOCEPTOR 6000 STANDARD\E.1400-606767\SP16-EC13090-S.idw
O.I.L. 1300
I.I.L. 1300
OVERALL HIEGHT 3400
ISOMETRIC VIEW
B B
ELEVATION VIEW SIDE VIEW
TOLERANCE: ALL DIMENSIONS 10mm UNLESS OTHERWISE STATED.
CLIENT: DISTRIBUTOR : CONFIDENTIAL - The drawings must not be disclosed to any third Drawn Date PROJECT :
parties without written permission from SPEL Environmental Sydney.
Unauthorised disclosure may result in prosecution. J.MAKIN 11/01/2016
© SPEL Environmental - This drawing is the property of SPEL
Environmental ABN: 83 151 832 629 and is subject to return on Check Date
A demand. It is submitted for the use only in connection with the TITLE
SPEL ECOCEPTOR A
proposal and contracts of SPEL Environmental with the expressed
conditions that it is not to be reproduced or copied in any form. Verified Date 6000 SERIES - E.1400/606767.RCP
This data must only be used in accordance with our standard GENERAL ARRANGEMENT
terms and conditions.
© Copyright Approved Date
SPEL Environmental accepts no responsibility for any loss or SCALE SIZE
N.T.S SHEET REV
damage resulting from any person acting on this information.
Request No. A3 1 1
The details and dimensions contained in this document may change,
please check with SPEL Environmental for confirmation of current RN2244 CUSTOMER CODE : DWG No.
specifications. SP16-EC13090-S
6 5 4 3 2 1
spel.com.au 5DRAWINGS
8000 Series
6 5 4 3 2 1
ACCESS MANHOLE
D 600 x 900 - COVERED D
LID - CLASS 'D'
INLET Ø1200 OUTLET Ø1200
RCP COLLAR RCP COLLAR
PLAN VIEW
O.D. 2580
I.D. 2480
100
C C
E:\Vault Working Folder\Designs\SPEL\PRODUCTS\ECOCEPTOR\8000 Series\E.2000-80120120\PROJECTS\ROZELLE INTERCHANGE- GPT1\SP20-EC11430-P1.idw
O.I.L. 1950
I.I.L. 1950
OVERALL HEIGHT 4600
ISOMETRIC VIEW
2650
B B
SIDE VIEW
ELEVATION VIEW
TOLERANCE: All Dimensions to Closest 10 mm & +/- 30 mm ALL INTERCONNECTING PIPEWORK, PITS AND ASSOCIATED DRAINAGE BY OTHERS
CLIENT: CONFIDENTIAL - The drawings must not be disclosed to any third Drawn Date PROJECT :
parties without written permission from SPEL STORMWATER .
Unauthorised disclosure may result in prosecution. J.MAKIN 24/03/2020
© SPEL STORMWATER - This drawing is the property of SPEL
STORMWATER ABN: 83 151 832 629 and is subject to return on Check Date TITLE
A demand. It is submitted for the use only in connection with the
proposal and contracts of SPEL STORMWATER with the expressed
SPEL ECOCEPTOR - SERIES 8000 A
conditions that it is not to be reproduced or copied in any form. Verified Date E.2000/80120120.RCP
This data must only be used in accordance with our standard GENERAL ARRANGEMENT
terms and conditions.
© Copyright Approved Date
SPEL STORMWATER accepts no responsibility for any loss or
damage resulting from any person acting on this information. SCALE SIZE SHEET REV
A3 1 1
24/03/2020 J.MAKIN INITIAL RELEASE The details and dimensions contained in this document may change, N.T.S
please check with SPEL STORMWATER for confirmation of current Request No.
1
CUSTOMER CODE : DWG No.
REV DATE BY DESCRIPTION CHK specifications. RN2254 SP20-EC11430-P1
6 5 4 3 2 1
10000 Series
6 5 4 3 2 1
REVISION HISTORY
3820 REV DESCRIPTION DESIGNER CREATION DATE CHECKED BY
1 INITIAL RELEASE J.MAKIN 3/06/2020
ACCESS MANHOLE
600 x 900
D D
INLET Ø1800 OUTLET Ø1800
RCP COLLAR RCP COLLAR
I.D. 3000
PLAN VIEW 625
625
100
C C
E:\Vault Working Folder\Designs\SPEL\PRODUCTS\ECOCEPTOR\10000 Series\STANDARD\E.2400-100180180\PROJECTS\PAUL PROJECT6032020\SP20-SF12720-P.idw
O.I.L. 2700
I.I.L. 2700
OVERALL HEIGHT 6000
ISOMETRIC VIEW
B B
INLET 3300
ELEVATION VIEW SIDE VIEW
TOLERANCE: ALL DIMENSIONS TO CLOSEST 10mm +/- 30mm UNLESS OTHERWISE STATED.
CLIENT: DISTRIBUTOR : CONFIDENTIAL - The drawings must not be disclosed to any third Drawn Date PROJECT :
parties without written permission from SPEL Environmental Sydney.
Unauthorised disclosure may result in prosecution. J.MAKIN 3/06/2020
© SPEL Environmental - This drawing is the property of SPEL
Check Date
A Environmental ABN: 83 151 832 629 and is subject to return on
demand. It is submitted for the use only in connection with the TITLE
SPEL ECOCEPTOR A
proposal and contracts of SPEL Environmental with the expressed
conditions that it is not to be reproduced or copied in any form.
Verified Date SERIES 10000 - E.2400/100180180.RCP
This data must only be used in accordance with our standard CONSTRUCTION DRAWING DETAILS
terms and conditions.
© Copyright Approved Date
SPEL Environmental accepts no responsibility for any loss or SCALE SIZE SHEET REV
damage resulting from any person acting on this information. N.T.S A3 1
Request No. 1
The details and dimensions contained in this document may change,
please check with SPEL Environmental for confirmation of current CUSTOMER CODE : DWG No.
specifications. SP20-SF12720-P
6 5 4 3 2 1
6 SPEL EcoceptorSPEL Ecoceptor
In-line Gross Pollutant Trap (GPT)
NSW HEAD OFFICE QLD MAIN OFFICE VIC & TAS OFFICE
100 Silverwater Rd, Silverwater NSW 2128 130 Sandstone Pl, Parkinson QLD 4115 897 Wellington Rd Rowville VIC 3178
PO Box 7138, Silverwater NSW 1811 P: +61 7 3271 6960 P: +61 3 5274 1336
P: +61 2 8705 0255 P: 1300 773 500 | E: qld.sales@spel.com.au P: 1800 810 139 | E: sales@spel.com.au
P: 1300 773 500 E: nsw.sales@spel.com.au
QLD SUNSHINE COAST BRANCH VIC GEELONG BRANCH
19‑27 Fred Chaplin Circuit, Bells Creek, QLD 4551 70 Technology Close, Corio,
P: 1300 773 500 | E: qld.sales@spel.com.au P: +61 3 5274 1336
P: 1800 810 139 | E: sales@spel.com.au
SA OFFICE WA OFFICE NZ OFFICE AUCKLAND
9 Hampden Road, Mount Barker SA 5251 2 Modal Crescent Canning Vale WA 6155 100 Montgomerie Road Airport Oaks
P: 1300 773 500 E: sales@spel.com.au P: +61 8 9350 1000 P: +64 9 276 9045
P: 1800 335 550 E: sales@spel.com.au E: sales@spel.com.au
NZ OFFICE WANGANUI NZ OFFICE WELLINGTON PHILIPPINES OFFICE METRO MANILA
43 Heads Road Wanganu New Zealand 41 Raiha St Porirua Wellington New Zealand Unit 2210 Lumiere Residences
P: +64 6 349 0088 | E: sales@spel.com.au P: +64 4 239 6006 | E: sales@spel.com.au Pasig Boulevard, Pasig City
P: +61 2 8705 0255
P: 1300 773 500 E: sales@spel.com.au
SINGAPORE OFFICE UK OFFICE UNITED KINGDOM USA OFFICE CLEVELAND
512 Chai Chee Lane, #06-04 Bedok Lancaster Rd Shrewsbury SY1 3NQ UK 4548 Industrial Parkway Cleveland,
Industrial Estate, Singapore 469028 P: +44 (0)1743 445200 | E: sales@spel.com.au Ohio 44135
P: +61 2 8705 0255 P: +61 2 8705 0255
P: 1300 773 500 | E: sales@spel.com.au P: 1300 773 500 E: sales@spel.com.au
We believe clean water is a
right not a privilege and we
work to ensure a joy in water
experience for you with your
children and grandchildren.
100 Silverwater Rd, Silverwater NSW 2128 Australia
Phone: (02) 8705 0255
Email: sales@spel.com.au
spel.com.au
SPEL Stormwater accepts no responsibility for any loss or damage resulting from any
person acting on this information. The details and dimensions contained in this document
may change, please check with SPEL Stormwater for confirmation of current specifications.