MSC THE FIRST PORTABLE APP BASED SYSTEM - CALIBRATION AND MEASUREMENT MULTIFUNCTION SMART CALIBRATOR - Dynatime SA
←
→
Page content transcription
If your browser does not render page correctly, please read the page content below
THE FIRST PORTABLE CALIBRATION AND MEASUREMENT APP‐BASED SYSTEM MSC MULTIFUNCTION SMART CALIBRATOR Low Energy e & Designed ad M in 100% Italy www.seneca.it/msc
MSC - Multifunction Smart Calibrator Handheld Bluetooth universal calibrator MSC (Multifunction Smart Calibrator) is a flexible device for maintenance and testing of sensors and process meters. With best-in-class accuracy at 0.05% for each type of input / output, MSC offers measurement, generation and simulation of analog and digital signals, temperature sensors and load cells. Data visualization and parameters setting are provided by Bluetooth 4.1 connection through the mobile app (MSC by SENECA) multilingual and available for iOS and Android devices. MSC includes programmable ramp generation functions, datalogging with data export in .csv format thanks to MSC tool software and the possible use as a Automatic Testing System through LabVIEW libraries. Equipped with a rechargeable lithium polymer battery, MSC can power external devices and sensors and can be used without continuous power supply with 20 hours battery life. The calibrator, with a reading capacity up to 100,000 measurements, is suitable for professional and industrial use for PLC programmers, maintenance technicians, technical assistance, measurement laboratories, control -and calibration, industry (laboratories, workshops and production), quality control. HIGHLIGHTS SIGNAL SIGNAL GENERATOR RAMPS FUNCTION DATALOGGER MEASUREMENT / SIMULATOR Single / Loop, max 9 segments 100.000 readings Csv data format Sampling time > 500 ms UNIVERSAL SIGNALS MULTILANGUAGE BLUETOOTH LOW LABVIEW LIBRARIES APP FOR INTERFACE ENERGY AND MICRO FOR AUTOMATIC TEST AND CONTROL USB CONNECTIONS EQUIPMENTS V, mV, mA, TC, RTD, load cell, pulse, frequency DIAGNOSTIC AND ACCURACY ELECTRICITY NETWORK LOOP POWER CALIBRATION AND BATTERY POWER SUPPLY SUPPLY For PLCs, sensors, regulators, valve, industrial devices of 0,05% From battery: 3.400 mAh @24 V every kind and brand (max lifetime 20 hours) MULTI-DEVICE DATA SIGNALLING MULTI-FUNCTION AND COSTS REDUCTION VISUALIZATION PROFESSIONAL USE Power-on, communication fail, Universal instrument BT pairing, datalogger on, Multiple configurations battery status leds, buzzer Real-time measurements overload reading / writing / visualization
-EX -SN +SN +EX-EX -SN +SN -EX -SN +EX +SN +EX -EX -SN +SN +EX mA mA °C °C DIAGRAMS SIGNAL FIGURA M1: MEASUREMENT FIGURA M1: FIGURA M2: SIGNAL FIGURA M2: MEASUREMENT SIGNAL FIGURA M3: MEASUREMENT FIGURA M3: FIGURA M4: SIGNAL FIGURA M4: MEASUREMENT MISURATORE MISURATORE DI CORRENTE PASSIVO DIMISURATORE CORRENTE TEMP. PASSIVO MISURATORE TEMP. CON TERMOCOPPIA CON TERMOCOPPIA PASSIVE (trasmettitore aCURRENT 4 fili) (4 WIRES) (trasmettitore a 4 fili) THERMOCOUPLE ACTIVE MISURATORE FIGURA M5: CURRENT DI CORRENTE (trasmettitore a 2 fili) (2 M5: MISURATORE ATTIVO FIGURA WIRES) DIMISURATORE (trasmettitore a 2 fili) CORRENTE FIGURA M6: ATTIVO THERMORESISTANCE MISURATORE FIGURA M6: DI TERMORESISTENZA DI TERMORESISTENZA MISURATORE MISURATORE DI TENSIONE HiRange DI TENSIONE HiRange MISURATORE MISURATORE CELLA DI CARICO CELLA DI CARICO + + EXCITATION + EXCITATION + EXCITATION - EXCITATION - 3W 2W 2W 4W 3W 2W 2W 4W SENSE + SENSE + SENSE - SENSE - SIGNAL - SIGNAL - SIGNAL + SIGNAL + -EX -SN +SN +EX -EX -SN +SN +EX-EX -SN -EX +SN -SN +EX +SN +EX-EX -SN +SN +EX -EX -SN +SN +EX -EX -SN +SN -SN -EX +EX +SN +EX -EX -SN +SN -EX +EX -SN +SN -EX -SN+EX +SN +EX -EX -SN +SN +EX mA mA °C °C mA mA °C °C V V Kg Kg FIGURA M3: FIGURA M3: FIGURA M4: FIGURA M4: FIGURA M5: DIMEASUREMENT SIGNAL SIGNAL FIGURA M6: MEASUREMENT MISURATORE DIFIGURA TENSIONE SIGNAL FIGURA M8: MEASUREMENT MISURATORE MISURATORE CORRENTE ATTIVOM5: DI FIGURA MISURATOREM6: ATTIVO CORRENTE MISURATORE DI TERMORESISTENZA DI TERMORESISTENZA FIGURA (trasmettitore FIGURA M7: M7: FIGURA M8: (trasmettitore MISURATORE a 2 fili) DI TENSIONE HiRange a 2 fili)MISURATORE CELLA DI CARICO HIGH RANGE VOLTAGE MISURATORE DI TENSIONE HiRange LOAD MISURATORE CELLACELL DI CARICO LOW MISURATORE FIGURA G1: RANGEMISURATORE DI TENSIONE G1: DIFIGURA LowRange FIGURA TENSIONE G2: LowRange MISURATORE FREQUENCY MISURATORE / PULSE G2: DI FREQUENZA/IMPULSI DI FREQUENZA/IMPULSI FIGURA GENERATORE DI CORRENTE PASSIVO DISIMULATORE GENERATORE CORRENTE TERMOCOPPIA PASSIVO SIMULATORE TERMOCOPPIA + + + + + +3 W + EXCITATION - EXCITATION EXCITATION + EXCITATION - 2W 2W 4W 3W 2W 2W 4W °C °C SENSE + SENSE - SIGNAL - SENSE + SENSE - SIGNAL - mA mA SIGNAL + SIGNAL + -EX -SN +SN +EX -EX -SN -EX +SN -SN +EX +SN +EX -EX -SN +SN +EX -EX -SN +SN +EX -EX -SN +SN +EX -EX -SN +SN -EX +EX -SN +SN -EX -SN+EX +SN -EX +EX -SN +SN +EX -EX -SN +SN +EX -EX -SN +SN +EX -EX -SN +SN +EX -EX -SN -EX +SN -SN+EX +SN +EX -EX -SN +SN +EX mA mA °C °C V V Kg Kg mV mV Hz Hz FIGURA M7: FIGURA M7: FIGURA M8: FIGURA M8: MISURATORE FIGURA G1: DI TENSIONE SIGNAL GENERATOR LowRange FIGURA MISURATORE G1: FIGURA MISURATORE DI G2: LowRange TENSIONE SIGNAL FIGURA G2: DISIMULATOR DI FREQUENZA/IMPULSI MISURATORE FREQUENZA/IMPULSI SIGNAL GENERATOR SIGNAL SIMULATOR SIMULATORE FIGURA G3: FIGURA G3: FIGURA G4: FIGURA G4: GENERATORE DI CORRENTE GENERATORE PASSIVO DI PASSIVO SIMULATORE TERMOCOPPIA CORRENTETERMOCOPPIA PASSIVE CURRENT+ + + THERMOCOUPLE+ ACTIVE GENERATORE FIGURA G5: CURRENT FIGURA DI CORRENTE G5: DIFIGURA GENERATORE ATTIVO CORRENTE G6: ATTIVO SIMULATORE THERMORESISTANCE FIGURA G6: DI TERMORESISTENZA DI TERMORESISTENZA SIMULATORE GENERATORE GENERATORE DI TENSIONE HiRange DISIMULATORE TENSIONE HiRange SIMULATORE CELLA DI CARICO CELLA DI CARICO °C °C °C °F °C °F mA mA V mA V mA 3W Kg 4W 3W Kg 4W 2W 2W 2W 2W -EX -SN +SN +EX -EX -SN -EX +SN -SN +EX +SN +EX -EX -SN +SN +EX -EX -SN +SN +EX-EX -SN -EX -SN +EX +SN +SN +EX -EX -SN +SN +EX -EX -SN+EX +SN +EX -EX -SN +SN +EX -EX -SN +SN +EX -EX -SN +SN -EX -SN +SN +EX-EX -SN +SN -EX -SN +EX +SN +EX -EX -SN +SN +EX mV mV Hz Hz + + FIGURA G3: FIGURA G3: FIGURA G4: FIGURA G4: SIGNAL FIGURA G5: DI GENERATOR GENERATORE CORRENTE GENERATORE ATTIVO FIGURA G5: DI CORRENTE SIMULATORE FIGURA ATTIVO G6: DI SIGNAL TERMORESISTENZA SIMULATORE FIGURA SIMULATOR G6: DI TERMORESISTENZA SIGNAL FIGURA G7: GENERATOR FIGURA G7: FIGURA G8: SIGNAL FIGURA G8: GENERATOR GENERATORE DI TENSIONE GENERATORE HiRange DISIMULATORE TENSIONE HiRange CELLA DI CARICO SIMULATORE CELLA DI CARICO GENERATORE LowRange DIGENERATORE TENSIONE LowRange GENERATORE FREQUENZA/IMPULSI HIGH RANGE VOLTAGE LOAD CELL LOW RANGE GENERATORE VOLTAGE DI TENSIONE FREQUENCY FREQUENZA/IMPULSI / PULSE °C °F °C °F V mA V mA3 W Kg Kg mV mV Hz Hz UTILIZZO DELLA APP DA MOBILE 4W 3W 4W 2W 2W 2W 2W Per utilizzare il calibratore MSC è necessario installare sul proprio dispositivo smartphone o tablet l’APP gratuita “MSC by Seneca” disponibile per dispositivi -EX -SNiOs e Android +SN e registrare +EX-EX i propri dati. -SN -EX +SN -SN +EX +SN +EX-EX -SN +SN +EX Verificare che il tablet -EX e/o -SN smartphone+SN sia dotato +EX-EX di bluetooth -SN 4.1+SNo -EX -SN +EX +SN +EX -EX -SN +SN +EX -SN +SN +EX-EX -SN -EX +SN -SN +EX +EX-EX +EX superiore. -EX -SN +SN +SN Per l’installazione della App su smartphone o tablet scansionare il QR Code riportato e inserire i dati richiesti nella pagina di iscrizio- ne. All’avvio dell’applicazione selezionare + il comando “Search” e, + + + nell’elenco di dispositivi disponibili, selezionare il dispositivo desi- derato per avviare la sincronizzazione con il proprio smartphone. Per garantire un corretto funzionamento del calibratore assicurarsi di aver selezionato il dispositivo corretto. FIGURA G7: FIGURA G7: FIGURA G8: FIGURA G8: MSC by SENECA - CALIBRATOR MANAGEMENT APP GENERATORE DI TENSIONE GENERATORE LowRange DIGENERATORE TENSIONE LowRangeFREQUENZA/IMPULSI GENERATORE FREQUENZA/IMPULSI mV mV Hz Hz -EX -SN +SN +EX-EX -SN -EX +SN -SN +EX +SN +EX-EX -SN +SN +EX In order to use the MSC calibrator you need to install on your own mobile device the 40 +free APP “MSC MI004960-I + MSC by Seneca” available for iOs and Android devices. Then you need to verify that the tablet and / or smartphone is equipped with bluetooth 4.1 or higher. For the installation of the App on smartphone or tablet you have to scan the QR Code. Start screen Signal measurement Signal generation / simulation screen example (1) Navigation menu screen example (2) Search
MSC - Multifunction Smart Calibrator FEATURE DIAGRAM 1 -EX -SN +SN +EX 2 4 1. Thermocouple measurement / 3 5 generation socket 2. Measurement / Generation bushing -EX 3. Measurement / Generation bushing -SN 4. Measurement / generating bushing + SN 5. Measuremet / generating bushing + EX 6. Power on / off button TECHNICAL DATA 7. Bluetooth RESET button GENERAL DATA 8. Power On Led From electricity network 230 Vac through USB standard battery 9. Bind connection on Led Power supply charge 10. Battery status indicator Led Battery power 1 batterie Lithium Polymer (LiPo) 3400 mAh; lifetime 8 hours (min @ 11. Bluetooth / USB communication Led max load), 20 hours (max) 6 7 12. Recording data Led Protection degree IP20 Operating temperature -20..50°C (non charging), 0..45°C (during charging) 8 9 13. Error signal Led Warehouse temperature 0..35°C 10 11 14. Micro USB connector for power / Humidity 30..90 % non condensing 12 13 communication Isolation Battery powered device, intrinsically isolated. No isolation towards USB port. 15. RESET button Overvoltage protection 230 Vac max senza danni permanenti 14 16. Battery charge warning Led 16 Rejection 50/60 Hz 15 Sampling frequency 10 Hz Operating mode Signal Meter, Signal Generator, Datalogger MSC 9 Dimension 147 x 88 x 25 mm Weight 330 g Bundle Connection cables (4 pcs), battery charger 14 Calibration certificate Approval On demand CE SUPPLIED CAVI CABLES IN DOTAZIONE Norms EN61326-1; EN61010-1 SIGNAL MEASUREMENT ACCURACY CAVO cable NERO CON with SPINA blackDA 4mmlead NERA UTILIZZO DEL CALIBRATORE Black 4mm Accuracy 0,03% (basic), 0,04% (current) -EX Resolution 1 µA; 1 mV; 5 µV; 0,1°C; 0,1uV/V SIGNAL GENERATION ACCURACY Accuracy 0,03% (basic), 0,04% (current) White CAVO cable BIANCOwith CONblack SPINA4mm lead DA 4mm NERA -SN Resolution 1 µA; 1 mV; 5µV; 0,1°C; 0,02 Ohm; 0,1 uV/V; INTERFACES AND SIGNALING MI004960-I Buttons On / Off - Pairing Power Communication CAVO BIANCO White CONred cable with SPINA 4mmDA 4mm leadROSSA +SN LED Error Pairing BT Datalogger on Red CAVOcable ROSSOwith CONred 4mm SPINA DAlead 4mm ROSSA Battery status +EX Buzzer Overload signaling / impossible simulating Standard input socket Nr.4 4mm input sockets Thermocouple socket Mini plug (7,9 mm) for TC measurement and simulation Power Supply Micro USB Micro USB Firmware update or ModBUS communication (Virtual COM) MSC Wireless communication Bluetooth Low Energy 4.1 verso Smart phone e Tablet Android o Ios SIGNAL MEASUREMENT FUNCTIONS Current 0..24 mA active / passive; protection ± 28 V SIGNAL RANGE Voltage (V) 0..27 V Voltage (mV) -10..+90 mV SIGNAL TYPE U.M. SIGNAL GENERATION SIGNAL MEASUREMENT Thermocouple Type J,K ,T, E, N, R, S, B, L Voltage (hi range) [dc V] 0..27 V 0..27 V Thermoresistance (2,3,4 wires) Pt100, Pt500, Pt1000, Cu50, Cu100, Ni100, Ni120 Load cell 350 Ohm; -0,2..+2,4mV/V Voltage (low range) [dc mV] -10..+90 mV -10..+90 mV Pulse Max counting 1.000 Hz Active current [dc mA] 0,1..+24 mA 0..+24 mA Frequency 0,1..1.000 Hz Passive current [dc mA] 0,1..+24 mA (3..29 V) 0..+24 mA SIGNAL GENERATION FUNCTIONS Pt100 [°C] -200..+859°C -200..+850°C Current 0,1..24 mA active / passive; protection ± 28 V Voltage (V) 0,1..24 V Pt500 [°C] -200..+859°C -200..+850°C Voltage (mV) -10..90 mV PT1000 [°C] -200..+859°C -200..+850°C Thermocouple Type J,K ,T, E, N, R,S, B, L Cu50 / Cu100 [°C] -180..+200°C -180..+200°C Thermoresistance (2 wires) Pt100, Pt500, Pt1000, Cu50, Cu100, Ni100, Ni120 Load cell 350 Ohm; -0,2..+2,4mV/V Ni100 / Ni120 [°C] -80..+260°C -60..+250°C Pulse Min 0,5 ms (1..24V) settable number of pulses Thermocouple J [°C] -210..+1200°C -210..+1200°C Frequency 0,1..1.000 Hz Thermocouple K [°C] -270..+1372°C -200..+1372°C DATALOGGER Thermocouple T [°C] -270..+400°C -200..+400°C Datalogger Yes Thermocouple E [°C] -270..+1000°C -200..+1000°C Sampling time >500 ms RAMP FUNCTION Thermocouple N [°C] -270..+1300°C -200..+1300°C Signal Current / Voltage / TC / RTD / Load cell Thermocouple R [°C] -50..+1768°C -50..+1768°C Functions Single / Loop Thermocouple S [°C] -50..+1768°C -50..+1768°C Type Max 9 segments, ramp resolution 100ms, min ramp duration 1 s Thermocouple B [°C] 0..+1820°C 250..+1820°C CALIBRATOR MANAGEMENT APP Publication MSC_1811EN – November 2018 Thermocouple L [°C] -200..+800°C -200..+800°C Available language Italian, English, German, French, Spanish Load Cell 350 Ohm [mV/V] -0,2..+2,4 mV/V -0,2..+2,4 mV/V O.S / Store IoS 10.3 or later (App Store) / Android 4.0.3 or later (Play Store) Functions menu General setup (operating mode, signal type, language selection) Pulse / Frequency [Hz] 0,1..1000 Hz (1..24 V) 0,1..1000 Hz (3..24 Vdc) Signal measurement (Voltage / current / passive current / thermocouple / thermoresistance / load cell / pulse; average-min-max value, reset contatore, meter pause; value sharing; change of scale ORDER CODES selection) Signal generation (Voltage / current / passive current / thermocouple / Code Description thermoresistance / load cell / pulse; on-off; change fo scale selection) MSC Multifunction Smart Calibrator - Signal meter / generator, Error signaling Out of scale - Overload generation Bluetooth app-based calibrator Low battery - Internal error MSC TOOL Windows software for firmware update and csv format data export Via Austria, 26 • 35127 Padova - (I) - Tel. +39 049 87.05.359 Fax +39 049 87.06.287 • www.seneca.it • info@seneca.it The material in this document is for information only and is subject to change without notice. While reasonable efforts have been made in the preparation of this document to assure its accuracy, SENECA assumes no liability resulting from errors or omissions, or from the use of the information contained herein.
You can also read