LOOP® TYPE 3
INSTALLATION MANUAL
GENERAL INFORMATION

GENERAL INFORMATION                                                                GUIDELINES                                                         Building expansion joints and tolerances
                                                                                                                                                      customary in building construction must
This assembly manual addresses all metal                                           These installation instructions have been                          be taken into account accordingly.
ceilings manufactured by durlum. The dif-                                          structured in accordance with the require-
ferent sections describe the related/rel-                                          ment of EN 13964:2007 and describe a                               durlum metal ceilings must always be as-
evant products.                                                                    proper assembly.                                                   sembled by expert dry building companies
                                                                                                                                                      who are capable of assessing the overall
durlum is a leading German manufacturer                                            The description does not exempt the user                           situation in the building, the metal ceil-
of metal ceilings and cladding elements,                                           from examining the structural conditions,                          ing, the cladding surface, as well as the
mainly made of galvanised sheet steel,                                             implementing the building code regula-                             structural conditions and are able to take
aluminium and expanded metal.                                                      tions and observing the information given                          suitable precautions for ensuring proper
                                                                                   in the building permit prior to starting as-                       assembly.
                                                                                   sembly. They have priority, but could not
                                                                                   be included here.                                                  If parts from different manufacturers are
                                                                                                                                                      used to assemble the ceiling, the relevant
              CERTIFICATE                                                          It is advisable always to draw up assembly
                                                                                   diagrams/drawings, to establish the loca-
                                                                                                                                                      mounting company must provide the cer-
                                                                                                                                                      tificates required by EN 13964:2007 and
                              The Certification Body
                      of TÜV SÜD Management Service GmbH                           tion where assembly is to begin and to es-                         must obtain suitable certificates of con-
                                       certifies that
                                                                                   tablish the required suspension points for                         formity itself.
                                                                                   the relevant ceiling system prior to starting
                                 durlum GmbH                                       assembly.                                                          Liability for proper selection of the products
                                  An der Wiese 5
                                 79650 Schopfheim
                                     Germany
                                                                                                                                                      and system conformity can only be as-
                                has established and applies                                                                                           sumed for the systems delivered by durlum.
                                                                                   STRUCTURAL PRECONDITIONS
               a Quality, Environmental and Energy Management System
                          for the following scope of application:

                Planning, development, manufacturing and sales of
                 metal ceilings, functional ceilings, wall claddings,
                    luminaries, lighting and daylight systems.
                                                                                                                                                      To prevent the parts from becoming dirty,
                     Performance of audits (Order No. 70014435)
                                                                                   Metal ceilings may usually be installed as                         gloves must be worn during assembly. If
                    has furnished proof that the requirements under:

                                 ISO 9001:2015
                                                                                   soon as the building is swept clean, but                           the ceiling products are delivered laminat-
                                ISO 14001:2015
                                ISO 50001:2018
                                                                                   at least when all wet work in the interior                         ed with a protective film, they must be pro-
                                       are fulfilled.                              has been completed and the building has                            tected from exposure to UV radiation [sun-
                The certificate is valid from 2020-05-30 until 2023-04-05.
                Certificate Registration No.: 12 100/104/340 25601 TMS.            been closed.                                                       light], the film must likewise be removed
                                                                                                                                                      from the goods no later than 4 weeks af-
                                Product Compliance Management
                                                                                   Prior to starting assembly, the suspension                         ter delivery, and the storage temperature
                                      Munich, 2020-04-15

                                                                                   points must be checked for their usabil-                           must not exceed 30°, since otherwise the
                                                                                   ity, and load introduction into the building                       adhesive on the panel may become hard-
                                                                                   must be guaranteed.                                                ened, and the protective film can no long-
The relevant products are described in the                                                                                                            er be removed.
marketing and sales documents. They are                                            When using wall mounting points, such as
both acoustically effective, and can also                                          brackets or wall anchors, the load-carrying
be used as design elements only. Specifi-                                          capacity of the wall in question must be                           STORAGE
cally, these products are:                                                         checked.
• Acoustic ceilings                                                                                                                                   durlum metal ceilings are usually delivered
• Chilled ceilings                                                                 If ceiling elements rest on brackets, pos-                         on pallets. It is advisable to leave the metal
• CHARACTER products                                                               sible wall movements must be taken into                            panels on the pallets as long as possible. If
                                                                                   account.                                                           the pallets need to be opened, the durlum
durlum differentiates between a wide                                                                                                                  POLYLAM ® should always be placed on its
range of ceiling systems, for example S1.                                          Only anchors for which a general building                          underside.
“S1” stands for system 1 clamping. In this                                         supervisory approval is available may be
system, there are different nomenclatures                                          used, and their minimum extraction force                           Storage must be carried out such that
that allow a further subdivision of the sys-                                       must be greater than 100 kg. The anchors                           damage is excluded.
tems.                                                                              must be mounted as specified by the
                                                                                   relevant anchors manufacturer. We rec-                             The assembly of the ceiling panels must
All durlum systems are systems of modular                                          ommend performing regular tensile stress                           not start until all dust-producing work has
design. This applies not only to the sub-                                          tests, to verify that anchors have been set                        been completed [swept clean].
structure but also the ceiling parts that are                                      correctly.
suspended, locked into place or placed                                                                                                                durlum products are certified according
on the substructure.                                                               durlum metal ceilings are dimensioned                              to ISO 9001 for development, production,
                                                                                   such that they carry their own weight of                           sales and also for service. Nevertheless, it is
durlum metal ceilings comply with the                                              the system construction plus a surface                             recommended to always subject the metal
standard EN 13964:2007 and are CE-cer-                                             load amounting to 40 N/m². Higher loads                            ceilings immediately to an inspection and
tified.                                                                            must be taken into account or suspended                            to report any complaints right away [usu-
                                                                                   separately in the construction, and the                            ally immediately following delivery or within
Appropriate static certificates are avail-                                         measures must be adapted to the situa-                             3 days]. Visible damage must be noted on
able for special systems marketed by us                                            tion at hand. Usually, built-in components                         the delivery note.
and for which no general approvals are                                             and loads must be suspended separately.
available, and appropriate designs com-
pliant with EN 13964 have been construct-                                          For ceiling systems that do not allow any                          STANDARDS AND REGULATIONS
ed. durlum lamps comply with standard                                              tolerance compensation within a module,
EN 60598-1 and are CE-certified.                                                   suitable material expansions must be tak-                          The relevant regulations applicable at the
                                                                                   en into account.                                                   installation site must be determined by

 2                                                                           © durlum GmbH | www.durlum.com | Subject to changes of dimensions and design. Errors reserved. All rights reserved. | Issued: 09.03.2021
GENERAL INFORMATION

the assembly company in question. The                                    such as the M6 threaded rod or the
ceilings marketed by durlum conform to                                   nonius hanger to the intended length
EN 13964. This standard also governs fire                                or order the correct length and mount
behaviour in accordance with EN 13501.                                   it on the raw ceiling.

                                                                   8.    Usually, the panel layout should be
APPLICATION                                                              started from the centre of the room,
                                                                         in order to be able to compensate
The application of durlum metal ceilings is                              the tolerance of the room and cut the
restricted, unless agreed upon otherwise, to                             panels in half, if necessary. The precise
interiors, so that, pursuant to EN 13964, class                          arrangement must always be done on
of use 1, corrosion protection class A, has                              the basis of the ceiling layout plan.
been defined here as standard. The use of
durlum lighting is restricted to interiors. The                    9.    durlum metal ceilings are usually pro-
lighting complies with protection class IP 20,                           vided with a cross support [primary
protection class 1 according to EN 60598-1.                              profile].

Should it become necessary to adjust the                           10. Use the layout plan to determine in
metal ceiling panels to the building by cut-                           which direction the cross reinforce-
ting, we recommend protecting the cut-                                 ment profiles are laid, either in parallel
ting edges from corrosion by means of a                                to the façade [usually] or vertically to
paint, to maintain the corrosion protection                            the façade. The cross reinforcement
class A.                                                               profiles should be mounted via a wall
                                                                       anchor or via a diagonal anchoring to
                                                                       prevent an axial movement. The corre-
QUALITY STANDARD                                                       sponding primary profiles are mount-
                                                                       ed at right angles to the secondary
For material properties, dimensions, toler-                            profiles. To this end, the system-specific
ances, colour deviations, the TAIM Direc-                              connecting elements are used, see
tives [Technical Association of Industrial                             system descriptions. The position of the
Metal Ceiling Manufacturers] applies.                                  primary profiles is established in the re-
                                                                       flected ceiling plan.

MOUNTING SEQUENCE                                                  11. The metal ceiling panels are often pro-
                                                                       vided with a joint tape [9x3mm], to
1.    Prepare ceiling and lighting installa-                           make for easier tolerance compensa-
      tion plan or adopt architect's plan.                             tion. Should a joint tape be used, the
                                                                       joints must also be re-aligned from
2.    Check ceiling lighting installation plan                         time to time, since the joint tape also
      versus structural conditions.                                    has tolerances. However, owing to the
                                                                       high production precision, it is also
3.    Prepare a bill of materials, including a                         possible to connect the panels without
      suitable work plan and retrieval/order                           a joint tape by using butt joints or pro-
      of the materials required.                                       vide them with rubber spacer naps. Al-
                                                                       ways ensure that the joints are aligned.
4.    Determine the required suspension
      points in accordance with the classes                        12. If the panels are placed on a perim-
      of use of EN 13964. The correspond-                              eter trim, we recommend our F-bracket
      ing suspension distances for the dif-                            as bracket or as stepped F-bracket. The
      ferent systems can be taken from the                             bracket secures the panel and protects
      detailed descriptions of the individual                          it against lifting. The ceiling panel is cut
      ceiling systems.                                                 with electric sheet shears [i.e. Treco
                                                                       shears] and adapted to the prevailing
5.    Establish which generally approved                               room dimensions. When calculating the
      anchor is suitable. Check the raw ceil-                          minimum support area [10mm], the
      ing and the walls. Mark the anchor                               dimensions of possible wall movement
      mounting holes and drill them. Mount                             should be taken into account.
      the anchors as specified by the an-
      chor manufacturer and carry out ex-                          13. Attachments or other loads are to be
      traction tests using the device recom-                           mounted separately. For logical rea-
      mended by the anchor manufacturer,                               sons these parts are integrated during
      if necessary.                                                    the mounting process.

6.    Use the same procedure when mount-                           14. After completion and pre-acceptance
      ing the wall brackets, mounting dis-                             of the ceiling, the sequence of joints
      tance about 400–625 mm, check the                                should be re-aligned. Soiled ceiling
      introduction of force into the wall.                             panels should be cleaned to give a
                                                                       perfect result for assembly.
7.    Shorten intended fastening elements,

© durlum GmbH | www.durlum.com | Subject to changes of dimensions and design. Errors reserved. All rights reserved. | Issued: 09.03.2021   3
LOOP ® TYPE 3 INSTALLATION MANUAL

                                                                                                                                                                                                     2

                                                              1

                                                                                                                                                                                  AP
                                                                                                                                                                           il e
                                                                                                                                                                        of
                  Se
                                                                                                                                                                  y   pr
                       co                                                                                                                                    ar
                            nd                                                                                                                          im
                                 ar
                                      yp                                                                                                           Pr
                                           ro
                                              fi   le
                                                        AS

1
                 U 1040
                                                                                                                                                   Modulgröße · Module size · Tailles du module = 966 x 1115.44 mm

    W2053-ST V

                   LOOP ® steel element                                                                                                                                     80,5                60
                                                                                                                                                                                                                           10
                                                                                                          LOOP® = 1004,25 x 1124,23 mm

                                                                                                                                                                                       139,43

                                                             Magnet
                                                                                                                                                                                                                                2

2

                                                                            U1042

                                                                              W2053-ST
                                                                                                                                                     Magnet · Magnet · Magnétique

                                                                                                                                         Langfeldplatte · Rectangular metal panels · Panneaux rectangulaires = 956 x 1.115 mm
                                                                  Screw connection

4                                                             © durlum GmbH | www.durlum.com | Subject to changes of dimensions and design. Errors reserved. All rights reserved. | Issued: 09.03.2021
INSTALLATION MANUAL LOOP ® TYPE 3

ABBREVIATIONS                                                      4.    When assembling the LOOP ® elements,                          if the instructions given below are not fol-
                                                                         the safety rope is screwed to the LOOP ®                      lowed or the luminaire is used improperly.
AH: Distance of the suspension hangers in                                element by means of a wing nut.
    axial direction of the primary profile                                                                                             1.   Unscrew the round          PUNTEO ® -J60
AP: Distance of primary profiles U 1040                                                                                                     mounting adapter.
AS: Distance of secondary profiles W 2053-
    ST

ASSEMBLY OF THE FALSE CEILING

Note:
Please take the S7 KS System Assembly in-
structions into account. With the following
exceptions:                                                        5.    Measure the position of the LOOP ® el-
                                                                         ement exactly using the laser [longi-
Distannce of the primary profile: ≤800 mm                                tudinal and transverse rows]. Hold the                        2.   Guide the screw component through
                                                                         LOOP ® element with the rear magnet                                the corresponding perforation of the
Assembly of the suspension                                               [20 pieces per standard element] from                              LOOP ® element and screw it on the op-
                                                                         below horizontally against the ceiling                             posite side using the nut.
Items 1-19 acc. to assembly instructions.                                S7 KS [friction force by magnet]. For
                                                                         the arrangement of the magnets, see
Item 20                                                                  below. To simplify assembly/disassem-
Cut the rail channel W 2053-ST to the re-                                bly, the magnets can be glued to the
quired length.                                                           LOOP ® element [e.g. LOCTITE].

                                                                                                 966
Item 21
                                                                                                                                                                            LOOP®
At the crossing points to the primary profile,
                                                                                                                                                           Ø 60
the rail channel W 2053-ST is screwed to the
L-shaped primary carrier U 1040 using a
self-securing screw connection M6.
                                                                                                                       1115,44

Item 22
The joint formation of the rail channel is
performed using the rail channel connec-                                                                                               3.   Now clip the PUNTEO® -J60 luminaire
tor W 2053-ST V.                                                                                                                            with the two lateral Clip springs into the
                                                                                                                                            upper part.
Items 23 and 24 are withdrawn.                                               Beispielanordnung Magnete Standardelemente
                                                                   6.    The installation is then performed with
                                                                         further elements similar to a puzzle.
ASSEMBLY OF LOOP® ELEMENTS                                               The elements are to be aligned by slid-
                                                                         ing them. To do so, the joints of the
1.    Wear clean cotton gloves.                                          LOOP ® ceiling are aligned horizontally
2.    Preassemble the safety ropes [min.                                 by pushing or pulling the adjacent ele-
      2 pieces per standard element] as                                  ment. Check the joint between the ele-
      shown on the drawing. Run rope                                     ments for flatness and uniform width.
      through the damper disc and safety                           7.    For connection to the wall, the elements
      rope anchor disc and secure it in the                              can be simply adapted to the room,
      armature disc by bending the web.                                  using a jigsaw. The cutting edge is cov-
                                                                         ered with a bracket or a plasterboard
                                                                         frieze. In the area of the glass wall, the
                                                                         cut is not covered. Ensure clean cut.

                                                                   MOUNTING OF LUMINAIRES

                                                                   Note: Installation and electrical connec-
                                                                   tion of the luminaire must be performed by
                                                                   an authorised skilled electrician [e.g. elec-
                                                                   tric installer] in accordance with VDE 0100,
                                                                   taking into account the technical informa-
                                                                   tion and the legal regulations in force in
                                                                   your country.

3.    Then run the preassembled rope                               Safe operation of the luminaire is only guar-
      through an elongated hole [in the                            anteed if these instructions are observed.
      area of the later fastening points of the                    This is why the Installation manual should
      safety rope] in the rail channel out of                      be kept in a safe place. The manufacturer
      the ceiling void downwards.                                  cannot assume any liability whatsoever

© durlum GmbH | www.durlum.com | Subject to changes of dimensions and design. Errors reserved. All rights reserved. | Issued: 09.03.2021                                            5
LOOP ® TYPE 3 INSTALLATION MANUAL

4.   If necessary, create a cutout with a
     diameter of 100 mm in the S7 ceiling
     on site.
5.   Mount ballasts/drivers in the ceiling
     void, possibly on U 1040.
6.   Perform electrical connection of the
     driver.
7.   Prior to acceptance, align the ele-
     ments precisely, if they have been
     moved by other trades.

Note:
The lumininaire must not be coat-
ed with a heat-insulating material.

The components are fitted with
electronic components, which can
become damaged in case of elec-
trostatic discharge. When handling the
components, ensure good earthing of the
environment.

DISASSEMBBLY OF THE CEILING
PANELS

1.   Wear clean cotton gloves.
2.   Pull LOOP ® elements, including
     PUNTEO® -J60, downwards to overcome
     their friction force.
3.   LOOP® elements, including PUNTEO®-J60,
     will fall into the safety ropes, but must al-
     ways be held.
4.   Release the safety ropes and set down
     the elements.
5.   Open S7 false ceiling in accordance
     with the S7 KS Installation manual.