XNX Universal Transmitter
←
→
Page content transcription
If your browser does not render page correctly, please read the page content below
XNX Universal Transmitter A universal transmitter for toxic and combustible gas detection that merges Honeywell’s industry-leading gas sensing technology on a single platform DASTEC S.R.L. Hipólito Yrigoyen 850. Piso 3 Of. 335 C1086AAN Buenos Aires - Argentina TE: (54-11) 4343-6200 // 4331-2288 Fax: (54-11) 4334-3120 Email: dastecsrl@dastecsrl.com.ar Web: www.dastecsrl.com.ar
XNX Universal Transmitter – I = IR Description Transmitter for use with Searchpoint Optima Plus, Searchpoint Excel infrared gas detectors from Honeywell Analytics. Modular system enabling connectivity to a wide variety of system architectures including 4-20mA/HART and optional integral relays or serial communications (Foundation Fieldbus or Modbus). Optional local IS HART port for Hand Held Interface (HHI). XNX Universal Transmitter – L = mV Description Transmitter for use with conventional mV flammable gas detectors from Honeywell Analytics and new Multi-Purpose Detector (MPD) providing field serviceable CB flammable and IR Slug flammable and CO2 detectors. Modular system enabling connectivity to a wide variety of system architectures including 4-20mA/HART and optional integral relays or serial communications (Foundation Fieldbus or Modbus). Optional local IS HART port for Hand Held Interface (HHI). XNX Universal Transmitter – T = ECC; - R -= Remote ECC Description Transmitter for use with conventional toxic gas detectors from Honeywell Analytics. Remote connection to these sensors. Modular system enabling connectivity to a wide variety of system architectures including 4-20mA/HART and optional integral relays or serial communications (Foundation Fieldbus or Modbus). Optional local IS HART port for Hand Held Interface (HHI). Environmental Operating Temperature -40°C to +65°C Operating Humidity 0% to 99% rH (non-condensing) Environmental Protection IP 66 and IP 67 Construction Material Painted LM25 Aluminum or painted 316L Stainless Steel Entries 5 x M25 or ¾ NPT for sensor and cabling connections Performance Refer to individual product specifications for Searchpoint Optima Plus, Searchline Excel, Searchline Horizon and conventional catalytic bead/electrochemical devices. Electrical Supply Voltage 18V to 32V (24V nominal) HA Approvals Hazardous Area ATEX: Ex II 2 G D, EEx d IIC T5 (Tamb -40°C to +65°C) / UL: Class 1, Div 1, Groups B, C, and D / Class 1, Zone 1 AEx d IIC T5 (Tamb -40°C to +65°C) / CSA: Class 1, Div 1, Groups B, C, and D T5 (Tamb -40°C to +65°C) Performance EU – ATEX, EN45544, EN50104, EN50270, EN50271, EN13980, EN60079 NA – UL 913, UL 1203, CSA 22.2 No. 152 Other – IEC61508 (SIL Assessment, SIL 2), IECEx OD 005 DASTEC S.R.L. Hipólito Yrigoyen 850. Piso 3 Of. 335 C1086AAN Buenos Aires - Argentina TE: (54-11) 4343-6200 // 4331-2288 Fax: (54-11) 4334-3120 Email: dastecsrl@dastecsrl.com.ar Web: www.dastecsrl.com.ar
Display Module & User Interface (Standard Supply) Display Type Backlit LCD Information Displayed Base Information: Gas Reading Gas Name and Units of measurement Fault and Alarm Status Other Information: Set up & configuration of field devices e.g. Alignment, calibration, alarm settings etc Refer to Optima Plus/Excel/SHC1 product manuals for information Interface Magnetic wand with terminal screwdriver (supplied each unit) 4-20mA & HART (Standard Supply) Description Fully configurable isolated 4-20mA & HART output module providing current sink, current source and isolated modes of operation. Configurable with or without HART data superimposed on the 4-20mA signal output. Multi- drop enabled where 4-20mA analogue signal is not required. Non-intrusive Interface Optional local IS port to enable HOT connection of a HART handheld configurator Operating Modes Current sink / Current source / Isolated current sink /Conventional or with HART data Output Range 0 to 22mA 4-20mA Signal Accuracy +/- 1% FS Max loop resistance 600 Ohms at 24Vdc loop supply Functions Supported via Gas Reading HART Gas Name and Units of measurement Fault and Alarm Status 4-20mA signal level General/Device Information Detailed Sensor Information Including: Optical Signal Level Dynamic Reserve (Excel Only) Raw reading 24V supply voltage Temperature RTC (Excel Only) Calibration and Configuration status Detailed Fault and Warning Information Fault and Alarm History Installation Configuration Calibration Forcing of 4-20mA output Local IS HART Port (Optional) Description Provides externally accessible IS connections to the XNX Universal transmitter to enable HOT connection of HC275/375 HART or equivalent hand held configurator Installation Fitted to one of the cable entries on the XNX Universal transmitter. Environmental Protection Terminals protected by cover to IP 66 and IP 67 when not in use DASTEC S.R.L. Hipólito Yrigoyen 850. Piso 3 Of. 335 C1086AAN Buenos Aires - Argentina TE: (54-11) 4343-6200 // 4331-2288 Fax: (54-11) 4334-3120 Email: dastecsrl@dastecsrl.com.ar Web: www.dastecsrl.com.ar
Relay Module (Optional) Description Provides three fully user configurable relay outputs that can be switched based on the current gas level and/or status of the transmitter. Provides 2 x SPCO alarm and 1 x SPCO fault relays Installation Fitted into XNX by qualified service engineer. Rating Maximum: 240VAC, 5A (non inductive load) Minimum: 5V, 10mA (non inductive load) Electrical Connections Fault: Common, Normally Open, Normally Closed Alarm 1: Common, Normally Open, Normally Closed Alarm 2: Common, Normally Open, Normally Closed Configuration Default Configurable Options Fault Relay: Fault Relay: Normally energized Normally energized / normally de-energized Non latching None Signal inhibit as fault Enable/disable Alarm 1 / 2 Relays: A1 / A2 Relays: Normally de-energized Normally energized / de-energized Non latching Latching / non latching Alarm rising on gas reading Alarm on rising / falling Alarm level 20% and 40% of scale Alarm level 10% to 90% of full scale Hysteresis of 2% of scale Re-setting of Latched Relays Easily accessible interface on display (if used) or via HART interface (local or remote) Note Use of the Relay Module or ‘Other’ Communications Module (E.g. Foundation Fieldbus) is mutually exclusive. However, relay function may be used in conjunction with standard communication output i.e. 4- 20mA with HART. Relay Specific Functions via HART Relay status information / Reset of latched conditions / Configuration of relays Interface Forcing of relay state Foundation Fieldbus Module (Optional) Description Foundation Fieldbus compliant digital communications interface enables connection of the XNX Universal transmitter to a multi-drop Foundation Fieldbus H1 network. Installation Fitted into housing base either at the factory or in the field by qualified service engineer. Connections Sig+, Sig- and Screen Physical Layer Conforms to IEC 1158-2 and ISA 50.02, 31.25Kbits/s Maximum No. of Nodes 32 Functions Supported Gas Reading Gas Name and Units of measurement Instrument status (OK, warning, fault, over-range) General/Device Information Remote zero and span calibration (detector dependent) Detailed Sensor Information Including: Optical Signal Level Dynamic Reserve (Excel Only) Raw reading 24V supply voltage Temperature RTC (Excel Only) Calibration and Configuration status Detailed Fault and Warning Information Fault and Alarm History Zero Calibration Modbus RTU Module (Optional) Description The Modbus output module provides an Isolated RS485 output to enable the connection of the XNX Universal transmitter to a multi-drop Modbus network Installation Fitted into housing base either at the factory or in the field by qualified service engineer. Connections RS485+, RS485-, Drain Physical Layer Isolated RS485, 1200 to 19.2K Baud Maximum No. of Nodes 254 XNX Universal compatible transmitters only Protocol Modbus RTU Functions Supported via Modbus Gas Reading Gas Name and Units of measurement Instrument status (OK, warning, fault, over-range) General/Device Information Remote zero and span calibration (detector dependent) Detailed Sensor Information Including: Optical Signal Level Dynamic Reserve (Excel Only) Raw reading 24V supply voltage Temperature RTC (Excel Only) Calibration and Configuration status Detailed Fault and Warning Information Fault and Alarm History Zero Calibration DASTEC S.R.L. Hipólito Yrigoyen 850. Piso 3 Of. 335 C1086AAN Buenos Aires - Argentina TE: (54-11) 4343-6200 // 4331-2288 Fax: (54-11) 4334-3120 Email: dastecsrl@dastecsrl.com.ar Web: www.dastecsrl.com.ar
Honeywell Analytics Lines of Business Commercial Industrial Portables Vulcain-brand gas detection from stand- Renowned Sieger and Manning gas Single or multi-gas Lumidor and other alone units to fully engineered, multi- detection systems with advanced premium detectors with compact, point systems, all offering cost-effective electrochemical, infrared and open path lightweight designs ranging from regulatory compliance sensing technologies simple alarm only units to advanced, » Applications: parking structures, » Applications: oil and gas, cold storage, fully configurable and serviceable chillers, mechanical rooms, office water/wastewater treatment, instruments towers, commercial buildings, chemicals, engine rooms, plastics » Applications: underground utility shopping centers, swimming pools, and fibers, agriculture, printing and and electricity ducts, boiler rooms, golf courses, schools and universities, light industrial post-fire sites, sewers, industrial laboratories plants, industrial hygiene, first responder teams, remote fleets High Tech/Government Technical Services Find out more A complete portfolio of gas and chemical 24/7 global network includes www.honeywellanalytics.com detection instrumentation including in- post-sales service and Systems frared spectroscopy (MST) with no cross Integration teams interference to Chemcassette paper- » Emergency call out, service Contact Honeywell Analytics: based solutions (MDA Scientific) offering contracts, on/off-site repair, training detection down to parts per billion and commissioning Americas » Applications: semiconductor » Complete range of spares, Honeywell Analytics Distribution, Inc. manufacturing and nanotechnology, consumables and accessories 405 Barclay Blvd. aerospace propulsion and safety, Lincolnshire, IL 60069 specialty chemicals industry USA Tel: +1 847 955 8200 Toll free: +1 800 538 0363 Europe, Middle East, Africa Asia Pacific Fax: +1 847 955 8208 Life Safety Distribution AG Honeywell Analytics Asia Pacific detectgas@honeywell.com Wilstrasse 11-U31 #508, Kolon Science Valley (1) CH-8610 Uster 187-10 Guro-Dong, Guro-Gu Switzerland Seoul, 152-050, Technical Services Tel: +41 (0)44 943 4300 Korea ha.global.service@honeywell.com Fax: +41 (0)44 943 4398 Tel: +82 (0)2 2025 0307 gasdetection@honeywell.com Fax: +82 (0)2 2025 0329 www.honeywell.com analytics.ap@honeywell.com 12791007 Please Note: While every effort has been made to ensure accuracy in this publication, no responsibility can be accepted for errors or omissions. Data may change, as well as legislation, and you are strongly advised to obtain copies of the most recently issued regulations, standards, and guidelines. This publication is not intended to form the basis of a contract. H_X5_DS01060_V1 10/07 © 2007 Honeywell Analytics DASTEC S.R.L. Hipólito Yrigoyen 850. Piso 3 Of. 335 C1086AAN Buenos Aires - Argentina TE: (54-11) 4343-6200 // 4331-2288 Fax: (54-11) 4334-3120 Email: dastecsrl@dastecsrl.com.ar Web: www.dastecsrl.com.ar
You can also read