SURNA CASSETTE FAN COIL - ISOSTREAM
←
→
Page content transcription
If your browser does not render page correctly, please read the page content below
ISOSTREAM® SURNA CASSETTE FAN COIL COOLING/OPTIONAL HEAT MODELS SCFC-08-X-X-AECM-X-X X This Surna fan coil is another addition to our full The unit uses an electronically commutated line of purpose-built fan coil products providing (EC) fan motor and modulating valves can be a wide range of choices for both ducted and integrated to allow for maximum output at ductless applications for small to large commercial minimum energy consumption. The EC fan motor indoor cannabis cultivation facilities. also provides extremely quiet operation. This ceiling cassette ductless fan coil can be For simple maintenance, the air filter is easily mounted in any comfort or process room where removable and washable and is made from self- wall mounting or remote ducting are not desired extinguishing acrylic with an efficiency class Merv taking up no extra floor or wall space. 2-4. This unit is available in many different sizes. These fan coils provide maximum flexibility and application specific options, ensuring a precise solution for your unique application. FEATURES AND BENEFITS Ductless Versatile Heating Options Ductless application for chilled Available in multiple sizes and Surna’s cassette fan coils offer water makes installation and can be mounted in any drop an electric heat kit or 4-pipe cleaning simple. ceiling or ceiling recess. hot water re-heat options for providing cooling and heating options for any space.
SPECIFICATIONS Custom configurations and sizes may be available upon request SCFC-08-V-X-AECM-X SCFC-08-V-X-AECM-X-EH SCFC-08-P-X-AECM-X PHYSICAL 2-Pipe, Cooling Only 2-Pipe with Electric Heat 4-Pipe with Hot Water Reheat Length 22-5/8 in (575 mm) Width 22-5/8 in (575 mm) Height 11-7/16 in (291 mm) Weight 66.1 lbs (30 kg) 67.5 lbs (30.6 kg) 66.1 lbs (30 kg) Water Inlet 3/4 in (19 mm) NPT Water Outlet 3/4 in (19 mm) NPT Condensate Drainage Outside Diameter: 1 in (25 mm) / Inside Diameter: 13/16 in (21 mm) Connection Number of Fan Blowers Single ELECTRICAL Power Supply (V/Ph/Hz) 220/1/60 Power Input in Cooling Mode 47 W Power Input in Heating Mode N/A 42W Fan Motor Running Current 0.43 A @220V Min.Circuit Ampacity (MCA) 0.27 A 11.6 A 0.27 A Max. Overcurrent Protection 15 A (MOP) Full Load Amps (FLA) 0.21 A 9.3 A 0.43 A CHILLED WATER COIL PERFORMANCE Total Airflow 476 CFM (808.7 m3/h) Cooling Capacity 15342 BTU/Hr (4.5 kW) 12852 BTU/Hr (3.91 kW) Sensible Cooling Capacity 10239 BTU/Hr (3 kW) 8794 BTU/Hr (2.81 kW) Cooling Water Flow Rate 3 GPM (681.4 L/h) 2.5 GPM (567.8 L/h) Cooling Water Pressure Drop 10.6 Ft/Head (31.8 kPa) 5.6 Ft/Head (16.8 kPa) Heating Water Flow Rate N/A 0.7 GPM (159 L/h) Heating Water Pressure Drop N/A 0.3 Ft/Head (0.9 kPa) ELECTRIC HEAT PERFORMANCE Max. Heating Capacity N/A 2 kW N/A REHEAT COIL PERFORMANCE Hydronic Heating Capacity N/A 8794 BTU/hr (2.81 kW) (EWT 1400F/60°C) CERTIFICATIONS ETL Note: a. Assumes entering water b. Data is based on fan running c. Data assumes specified GPM d. All dimensions are temperature (EWT) of 450 F at maximum speed @ 220V approximate within 1/16 of an (7.220 C) inch of those indicated P 303.993.5271 August 2021 surna.com E info@surna.com All data subject to change without notice
ISOSTREAM® SURNA CASSETTE FAN COIL COOLING/OPTIONAL HEAT MODELS SCFC-16-X-X-AECM-X-X X This Surna fan coil is another addition to our full The unit uses an electronically commutated line of purpose-built fan coil products providing (EC) fan motor and modulating valves can be a wide range of choices for both ducted and integrated to allow for maximum output at ductless applications for small to large commercial minimum energy consumption. The EC fan motor indoor cannabis cultivation facilities. also provides extremely quiet operation. This ceiling cassette ductless fan coil can be For simple maintenance, the air filter is easily mounted in any comfort or process room where removable and washable and is made from self- wall mounting or remote ducting are not desired extinguishing acrylic with an efficiency class Merv taking up no extra floor or wall space. 2-4. This unit is available in many different sizes. These fan coils provide maximum flexibility and application specific options, ensuring a precise solution for your unique application. FEATURES AND BENEFITS Ductless Versatile Heating Options Ductless application for chilled Available in multiple sizes and Surna’s cassette fan coils offer water makes installation and can be mounted in any drop an electric heat kit or 4-pipe cleaning simple. ceiling or ceiling recess. hot water re-heat options for providing cooling and heating options for any space.
SPECIFICATIONS Custom configurations and sizes may be available upon request SCFC-16-V-X-AECM-X SCFC-16-V-X-AECM-X-EH SCFC-16-P-X-AECM-X PHYSICAL 2-Pipe, Cooling Only 2-Pipe with Electric Heat 4-Pipe with Hot Water Reheat Length 44-7/8 in (1140 mm) Width 22-13/16 in (579 mm) Height 11-7/16 in (291 mm) Weight 115 lbs (52.2 kg) 120 lbs (54.4 kg) 115 lbs (52.2 kg) Water Inlet 3/4 in (19 mm) NPT Water Outlet 3/4 in (19 mm) NPT Condensate Drainage Outside Diameter: 1 in (25 mm) / Inside Diameter: 13/16 in (21 mm) Connection Number of Fan Blowers Twin ELECTRICAL Power Supply (V/Ph/Hz) 220/1/60 Power Input in Cooling Mode 89 W Power Input in Heating Mode N/A 84 W Fan Motor Running Current 0.81 A @220V Min.Circuit Ampacity (MCA) 0.51 A 17.6 A 0.51 A Max. Overcurrent Protection 15 A 20 A 15 A (MOP) Full Load Amps (FLA) 0.4 A 14.04 0.4 A CHILLED WATER COIL PERFORMANCE Total Airflow 853 CFM (1449.3 m3/h) Cooling Capacity 28497 BTU/Hr (8.4 kW) 16078 BTU/Hr (4.71 kW) Sensible Cooling Capacity 19128 BTU/Hr (5.6 kW) 11280 BTU/Hr (3.31 kW) Cooling Water Flow Rate 5.6 GPM (1271.9 L/h) 3.2 GPM (726.8 L/h) Cooling Water Pressure Drop 12.8 Ft/Head (38.3 kPa) 4.5 Ft/Head (13.4 kPa) Heating Water Flow Rate N/A 1.3 GPM (295.3 L/h) Heating Water Pressure Drop N/A 0.5 Ft/Head (1.5 kPa) ELECTRIC HEAT PERFORMANCE Max. Heating Capacity N/A 3 kW N/A REHEAT COIL PERFORMANCE Hydronic Heating Capacity N/A 25172 BTU/Hr (7.38 kW) (EWT 1400F/60°C) CERTIFICATIONS ETL Note: a. Assumes entering water b. Data is based on fan running c. Data assumes specified GPM d. All dimensions are temperature (EWT) of 450 F at maximum speed @ 220V approximate within 1/16 of an (7.220 C) inch of those indicated P 303.993.5271 August 2021 surna.com E info@surna.com All data subject to change without notice
ISOSTREAM® SURNA CASSETTE FAN COIL COOLING/OPTIONAL HEAT MODELS SCFC-20-X-X-AECM-X-X X This Surna fan coil is another addition to our full The unit uses an electronically commutated line of purpose-built fan coil products providing (EC) fan motor and modulating valves can be a wide range of choices for both ducted and integrated to allow for maximum output at ductless applications for small to large commercial minimum energy consumption. The EC fan motor indoor cannabis cultivation facilities. also provides extremely quiet operation. This ceiling cassette ductless fan coil can be For simple maintenance, the air filter is easily mounted in any comfort or process room where removable and washable and is made from self- wall mounting or remote ducting are not desired extinguishing acrylic with an efficiency class Merv taking up no extra floor or wall space. 2-4. This unit is available in many different sizes. These fan coils provide maximum flexibility and application specific options, ensuring a precise solution for your unique application. FEATURES AND BENEFITS Ductless Versatile Heating Options Ductless application for chilled Available in multiple sizes and Surna’s cassette fan coils offer water makes installation and can be mounted in any drop an electric heat kit or 4-pipe cleaning simple. ceiling or ceiling recess. hot water re-heat options for providing cooling and heating options for any space.
SPECIFICATIONS Custom configurations and sizes may be available upon request SCFC-20-V-X-AECM-X SCFC-20-V-X-AECM-X-EH SCFC-20-P-X-AECM-X PHYSICAL 2-Pipe, Cooling Only 2-Pipe with Electric Heat 4-Pipe with Hot Water Reheat Length 32-11/16 in (830 mm) Width 32-11/16 in (830 mm) Height 11-7/16 in (291 mm) Weight 110 lbs (49.9 kg) 110.5 ibs (50.1 kg) 110 lbs (49.9 kg) Water Inlet 3/4 in (19 mm) NPT Water Outlet 3/4 in (19 mm) NPT Condensate Drainage Outside Diameter: 1 in (25 mm) / Inside Diameter: 13/16 in (21 mm) Connection Number of Fan Blowers Single ELECTRICAL Power Supply (V/Ph/Hz) 220/1/60 Power Input in Cooling Mode 224 W Power Input in Heating Mode N/A 219 W Fan Motor Running Current 2.04 A @220V Min.Circuit Ampacity (MCA) 1.27 A 2.4 A 1.27 A Max. Overcurrent Protection 15 A 25 A 15 A (MOP) Full Load Amps (FLA) 1.02 A 19.2 A 2.04 A CHILLED WATER COIL PERFORMANCE Total Airflow 1300 CFM (2208.7 m3/h) Cooling Capacity 32423 BTU/Hr (9.5 kW) 22318 BTU/Hr (6.54 kW) Sensible Cooling Capacity 23166 BTU/Hr (6.8 kW) 15307 BTU/Hr (4.49kW) Cooling Water Flow Rate 6.4 GPM (1453.6 L/h) 4.4 GPM (999.3 L/h) Cooling Water Pressure Drop 8.8 Ft/Head (26.4 kPA) 6.8 Ft/Head (20.3 kPa) Heating Water Flow Rate N/A 1.6 GPM (363.4 L/h) Heating Water Pressure Drop N/A 0.7 Ft/Head (2.1 kPa) ELECTRIC HEAT PERFORMANCE Max. Heating Capacity N/A 4 kW N/A REHEAT COIL PERFORMANCE Hydronic Heating Capacity N/A 31509 BTU/Hr (9.23 kW) (EWT 1400F/60°C) CERTIFICATIONS ETL Note: a. Assumes entering water b. Data is based on fan running c. Data assumes specified GPM d. All dimensions are temperature (EWT) of 450 F at maximum speed @ 220V approximate within 1/16 of an (7.220 C) inch of those indicated P 303.993.5271 August 2021 surna.com E info@surna.com All data subject to change without notice