Phase II Environmental Site Assessment - 85 York Road West, Yorkton, Saskatchewan

Page created by Virginia Bailey
 
CONTINUE READING
Phase II Environmental Site Assessment - 85 York Road West, Yorkton, Saskatchewan
Phase II Environmental Site
Assessment
85 York Road West,
Yorkton, Saskatchewan

                        Prepared for:

                        Alvarez & Marsal Canada
                        Inc., in its capacity as Monitor
                        of Contour Realty Inc.

                        Suite 1110, 250 6th Avenue SW
                        Calgary, Alberta T2P 3H7
                        January 8, 2021

                        Pinchin File: 284505.001

                                                   © 2021 Pinchin Ltd.
Phase II Environmental Site Assessment - 85 York Road West, Yorkton, Saskatchewan
---                  phase ll Environmental site Assessment                                                   January 8, 2021
/ Pl NC H lN      '    85 York Road West, , Yorkton, Saskatchewan                                       Pinchin File: 284505.001
\-/                    Alvarez & Marsat Canada lnc., in iG capacity as Monitor of Contour Reatty lnc.

         lssued To:                           Alvarez & Marsal Canada lne., in its capacity as Monitor of
                                              Contour Realty lnc.
         lssued On:                           January 8,2021
         Pinchin File:                        284505.001
         lssuing Office:                      Regina, SK

        Author:                             Cody Leask, Dipl. Env., EP
                                            Project Coordinator
                                            306.500.3022
                                            cleask@pinchin.com

        Reviewer:                           Reese Giraudier, Dipl" (ENV), A.Sc,T.
                                            Project Manager
                                            639.739.0114
                                            rqiraudier@pinchin.com

                                                 l2-                             J./-PJ>

        Reviewer:                           Timothy J. Jaques, B. Sc.,          . Geo.
                                            Senior Technical Advisor
                                            403.543.1945
                                            tjaques@pinchin.com
Phase II Environmental Site Assessment - 85 York Road West, Yorkton, Saskatchewan
Phase II Environmental Site Assessment                                                     January 8, 2021
             85 York Road West, Yorkton, Saskatchewan                                           Pinchin File: 284505.001
             Alvarez & Marsal Canada Inc., in its capacity as Monitor of Contour Realty Inc.

EXECUTIVE SUMMARY

Pinchin Ltd. (Pinchin) was retained through an Authorization to Proceed, Limitation of Liability and Terms
of Engagement signed by Alvarez & Marsal Canada Inc., in its capacity as Monitor of 101098672
Saskatchewan Ltd., Morris Industries Lt., Morris Sales and Service Ltd., Contour Realty Inc., and Morris
Industries (US) Inc., and not its personal or corporate capacity (Client) to conduct a Phase II
Environmental Site Assessment (ESA) of the property located at 85 York Road West, in Yorkton,
Saskatchewan (hereafter referred to as the Site).

The Site is developed with a single-storey industrial building with a second-storey office space, a
materials/storage yard and employee parking areas, occupied by Morris Industries Ltd.

The purpose of this Phase II ESA was to address potential issues of environmental concern identified
during a 2004 Phase II ESA and 2019 Phase I ESA Update completed by P. Machibroda Engineering Ltd.
(PMEL) to facilitate the potential divestiture of the Site.

Pinchin reviewed the PMEL reports which identified the following area of potential environmental concern
(APEC):

         •            A fueling station, equipped with underground and aboveground storage tanks and a
                      pump island, were historically located approximately 30 metres east of the Site on the
                      adjacent former Dairy Producers Co-operative Ltd. property located at 41 York Road
                      West. To evaluate this APEC, the 2004 PMEL Phase II ESA involved the drilling and
                      installation of a borehole/monitoring well on-Site to determine if the off-Site fueling station
                      had affected soil and groundwater quality at the Site. Although the soil and groundwater
                      analytical results were found to be compliant with the regulatory guidelines in place at the
                      time of the assessment, the 2019 PMEL Phase I ESA Update indicated that
                      concentrations of benzene in a groundwater sample collected from the monitoring well
                      exceeded the present day Saskatchewan Ministry of Environment (MOE), Saskatchewan
                      Environmental Quality Standards, dated June 2015, specifically those standards for
                      industrial land use and a fine-grained soil profile (hereafter referred to as the Tier 1
                      SEQS).

Based on the above-mentioned finding, Pinchin recommended that a Phase II ESA be conducted at the
Site to determine if the above-noted APEC had affected Site soil or groundwater quality.

The Phase II ESA was completed at the Site by Pinchin between December 10 and 14, 2020, and
consisted of the advancement of two boreholes, both of which were completed as groundwater
monitoring wells.

© 2021 Pinchin Ltd.                                                                                              Page ii
Phase II Environmental Site Assessment - 85 York Road West, Yorkton, Saskatchewan
Phase II Environmental Site Assessment                                                    January 8, 2021
             85 York Road West, Yorkton, Saskatchewan                                          Pinchin File: 284505.001
             Alvarez & Marsal Canada Inc., in its capacity as Monitor of Contour Realty Inc.

Select “worst case” soil samples collected during the borehole drilling program were submitted for
laboratory analysis of benzene, toluene, ethylbenzene and xylenes (collectively referred to as BTEX),
petroleum hydrocarbons in the F1 to F4 fraction ranges (PHC F1 to F4), volatile organic compounds
(VOCs), polycyclic aromatic hydrocarbons (PAHs) and total lead. Groundwater samples collected from
the newly installed monitoring wells were submitted for laboratory analysis of BTEX, PHC F1 and F2,
VOCs, PAHs and total lead.

A review of available water well records did not identify any potable water wells located within 500 m of
the Site and the Site and surrounding properties are located within city limits and supplied with treated
potable water supplied by the City of Yorkton. There were also no surface water bodies identified within
500 metres of the Site. Based on this information, Site and surrounding land use, and underlying fine-
grained soil profile, the soil and groundwater quality at the Site were assessed based on the MOE Tier 2
SEQS, specifically those standards for industrial land use and a fine-grained soil profile, with freshwater
aquatic life and potable groundwater excluded from consideration as applicable exposure pathways
(hereafter referred to as the Tier 2 SEQS).

The reported concentrations of BTEX, PHC F1 to F4, VOCs, PAHs and total lead in the soil samples
submitted for analysis were all compliant with the Tier 2 SEQS. The reported concentrations of BTEX,
PHC F1 and F2, VOCs, PAHs and total lead in the groundwater samples submitted for analysis were also
found to be compliant with the Tier 2 SEQS.

Based on the findings of this Phase II ESA, it is Pinchin’s opinion that no further subsurface investigation
is required for the Site in relation to the findings of the previous investigations at this time.

It should be noted that benzene and/or toluene concentrations in the groundwater samples submitted for
laboratory analysis exceeded the MOE Discharge and Discovery Reporting Standards, dated October 1,
2017 (DDRS) and as stated in the DDRS, any concentrations exceeding these limits will need to be
reported to the MOE.

Pinchin will submit a historical discovery report to the MOE under separate cover. Pinchin recommends
that the adjacent property owner to the east be notified of the MOE DDRS exceedances which appear to
have resulted from the former fueling station that was located on this property.

 This Executive Summary is subject to the same standard limitations as contained in the report and must be read in
 conjunction with the entire report.

© 2021 Pinchin Ltd.                                                                                            Page iii
Phase II Environmental Site Assessment                                                                                   January 8, 2021
               85 York Road West, Yorkton, Saskatchewan                                                                         Pinchin File: 284505.001
               Alvarez & Marsal Canada Inc., in its capacity as Monitor of Contour Realty Inc.

TABLE OF CONTENTS

1.0      INTRODUCTION.............................................................................................................................. 1
         1.1        Background........................................................................................................................... 1
         1.2        Scope of Work ...................................................................................................................... 2
2.0      METHODOLOGY ............................................................................................................................. 3
         2.1        Borehole Investigation .......................................................................................................... 3
         2.2        Monitoring Well Installation................................................................................................... 3
         2.3        Groundwater Monitoring ....................................................................................................... 4
         2.4        Sampling and Laboratory Analysis ....................................................................................... 4
                    2.4.1    Soil ......................................................................................................................... 4
                    2.4.2    Groundwater .......................................................................................................... 4
                    2.4.3    Analytical Laboratory ............................................................................................. 5
         2.5        QA/QC Protocols .................................................................................................................. 5
         2.6        Regulatory Criteria ................................................................................................................ 6
3.0      RESULTS ......................................................................................................................................... 8
         3.1        Site Geology and Hydrogeology ........................................................................................... 8
         3.2        Soil Headspace Vapour Concentrations .............................................................................. 8
         3.3        Field Observations ................................................................................................................ 9
         3.4        Analytical .............................................................................................................................. 9
                    3.4.1    Soil ......................................................................................................................... 9
                    3.4.2    Groundwater .......................................................................................................... 9
4.0      FINDINGS AND CONCLUSIONS .................................................................................................... 9
5.0      TERMS AND LIMITATIONS .......................................................................................................... 11

© 2021 Pinchin Ltd.                                                                                                                                  Page iv
Phase II Environmental Site Assessment                                                    January 8, 2021
             85 York Road West, Yorkton, Saskatchewan                                          Pinchin File: 284505.001
             Alvarez & Marsal Canada Inc., in its capacity as Monitor of Contour Realty Inc.

APPENDICES

APPENDIX I                   Figures
APPENDIX II                  Borehole Logs
APPENDIX III                 Summary Tables
APPENDIX IV                  Laboratory Certificates of Analysis
APPENDIX V                   Water Well Reports

FIGURES

Figure 1 - Key Map
Figure 2 - Site Plan with New Monitoring Well Locations
Figure 3 – Borehole and Monitoring Well Location Plan

TABLES

Table 1 - Monitoring Well Construction and Groundwater Monitoring Details
Table 2 - Samples Submitted for Laboratory Analysis and Particle Size Analysis
Table 3 - BTEX, Petroleum Hydrocarbon and Total Lead Analysis for Soil
Table 4 - Volatile Organic Compound Analysis for Soil
Table 5 - Polycyclic Aromatic Hydrocarbon Analysis for Soil
Table 6 - Landfill Characterization for Soil
Table 7 - BTEX, Petroleum Hydrocarbon and Total Lead Analysis for Groundwater
Table 8 - Volatile Organic Compound Analysis for Groundwater
Table 9 - Polycyclic Aromatic Hydrocarbon Analysis for Groundwater

© 2021 Pinchin Ltd.                                                                                             Page v
Phase II Environmental Site Assessment                                                    January 8, 2021
             85 York Road West, Yorkton, Saskatchewan                                          Pinchin File: 284505.001
             Alvarez & Marsal Canada Inc., in its capacity as Monitor of Contour Realty Inc.

1.0      INTRODUCTION

Pinchin Ltd. (Pinchin) was retained through an Authorization to Proceed, Limitation of Liability and Terms
of Engagement signed by Alvarez & Marsal Canada Inc., in its capacity as Monitor of 101098672
Saskatchewan Ltd., Morris Industries Lt., Morris Sales and Service Ltd., Contour Realty Inc., and Morris
Industries (US) Inc., and not its personal or corporate capacity (Client) to conduct a Phase II
Environmental Site Assessment (ESA) of the property located at 85 York Road West, in Yorkton,
Saskatchewan (hereafter referred to as the Site).

The Site is developed with a single-storey industrial building with a second-storey office space, a
materials/storage yard and employee parking areas, occupied by Morris Industries Ltd.

The purpose of this Phase II ESA was to address potential issues of environmental concern identified
during 2004 Phase II ESA and 2019 Phase I ESA Update reports prepared by P. Machibroda Engineering
Ltd. (PMEL) to facilitate the potential divestiture of the Site.

This Phase II ESA was completed in general accordance with the Canadian Standards Association
document entitled Phase II Environmental Site Assessment, CSA Standard Z769-00 (R2018), dated 2000
and reaffirmed in 2018.

1.1      Background

Pinchin reviewed the following documents that were provided to Pinchin by the Client:

         •            Phase II Environmental Site Assessment, Morris Industries Ltd, Main Manufacturing
                      Plant, 85 York Road, Yorkton, Saskatchewan, prepared by PMEL for Morris Industries
                      Ltd. and dated March 31, 2004 (2004 PMEL Phase II ESA Report); and

         •            Phase I Environmental Site Assessment – Update, 85 York Road, Yorkton,
                      Saskatchewan, completed by PMEL for Morris Industries and dated August 21, 2019
                      (2019 PMEL Phase I ESA Update Report).

Based on Pinchin’s review of the above-referenced reports, the following area of potential environmental
concern (APECs) was identified that could give rise to potential subsurface impacts in connection with the
Site:

         •            A fueling station equipped with underground and aboveground storage tanks and a pump
                      island was historically located approximately 30 m east of the Site on the adjacent former
                      Dairy Producers Co-operative Ltd. property located at 41 York Road West. To evaluate
                      this APEC, the 2004 PMEL Phase II ESA involved the drilling and installation of a
                      borehole/monitoring well on-Site to determine if the off-Site fueling station had affected

© 2021 Pinchin Ltd.                                                                                       Page 1 of 12
Phase II Environmental Site Assessment                                                     January 8, 2021
             85 York Road West, Yorkton, Saskatchewan                                           Pinchin File: 284505.001
             Alvarez & Marsal Canada Inc., in its capacity as Monitor of Contour Realty Inc.

                      soil and groundwater quality at the Site. Although the soil and groundwater analytical
                      results were found to be compliant with the regulatory guidelines in place at the time of
                      the assessment, the 2019 PMEL Phase I ESA Update indicated that concentrations of
                      benzene in a groundwater sample collected from the monitoring well exceeded the
                      present day Saskatchewan Ministry of Environment (MOE), Saskatchewan
                      Environmental Quality Standards, dated June 2015, specifically those standards for
                      industrial land use and a fine-grained soil profile (hereafter referred to as the Tier 1
                      SEQS); and

         •            It should be noted that the appendices, including drawings, borehole logs and the
                      laboratory report from the 2004 PMEL Phase II ESA Report were not provided for
                      Pinchin’s review.

Based on the findings noted above, Pinchin recommended that a Phase II ESA be completed at the Site
to determine if the above-noted APEC had affected Site soil and/or groundwater quality.

1.2      Scope of Work

The scope of work completed by Pinchin, as outlined in the Pinchin proposal entitled Proposal for Phase
II Environmental Site Assessment, 85 Yorkton Road West, Yorkton, Saskatchewan, submitted to the
Client on November 24, 2020, included the following tasks:

         •            Advancement of two boreholes following the clearance of underground services, both of
                      which were instrumented with a monitoring well;

         •            Submission of select “worst case” soil samples for laboratory analysis of benzene,
                      toluene, ethylbenzene and xylenes (collectively referred to as BTEX), petroleum
                      hydrocarbons in the F1 to F4 fraction ranges (PHC F1 to F4), volatile organic compounds
                      (VOCs), polycyclic aromatic hydrocarbons (PAHs) and/or lead;

         •            Collection of groundwater samples from each of the newly installed monitoring wells,
                      following well development and purging, for laboratory analysis of BTEX, PHC F1 and F2,
                      VOCs, PAHs and/or total lead;

         •            Comparison of the soil and groundwater laboratory analytical results to the applicable
                      regulatory criteria; and

         •            Preparation of a factual report detailing the findings of the Phase II ESA complete with
                      recommendations.

© 2021 Pinchin Ltd.                                                                                        Page 2 of 12
Phase II Environmental Site Assessment                                                    January 8, 2021
             85 York Road West, Yorkton, Saskatchewan                                          Pinchin File: 284505.001
             Alvarez & Marsal Canada Inc., in its capacity as Monitor of Contour Realty Inc.

2.0      METHODOLOGY

The investigation methodology was conducted in general accordance with Pinchin standard operating
procedures (SOPs).

2.1      Borehole Investigation

Pinchin retained Maple Leaf Drilling Ltd. to complete the borehole drilling program at the Site on
December 10, 2020 following the clearance of underground services in the vicinity of the work area by
public utility locators and a private utility locator retained by Pinchin.

The boreholes MW20-01 and MW20-02 were advanced to a maximum depth of 6.10 metres below
ground surface (mbgs) using a track-mounted drill rig. Soil samples were collected at regular 0.75 m
intervals from the auger flights. Discrete soil samples were collected from the auger flights and
containerized in laboratory-supplied containers with preservatives added where required.

Subsurface soil conditions were logged on-Site by Pinchin personnel at the time of drilling. Soil samples
were examined for visual and olfactory evidence of impact and a portion of each sample was field-
screened for VOC and PHC-derived vapour concentrations in soil headspace using a RKI Eagle II field
detector equipped with photoionization and combustible vapour detection capabilities calibrated to
isobutylene and hexane standards respectively with the methane elimination switch enabled.

The locations of the boreholes are shown on Figures 2 and 3, and a description of the soil profile
encountered during the drilling program is documented in the borehole logs included in Appendix II.

2.2      Monitoring Well Installation

Groundwater monitoring wells were installed in boreholes MW20-01 and MW20-02 to enable groundwater
monitoring and sampling. The monitoring wells were constructed with 5.08 centimetre (cm) (2 inch) inner
diameter (ID) flush-threaded Schedule 40 polyvinyl chloride (PVC) risers, followed by a length of 5.08 cm
ID No. 10 slot PVC screen that intersected the suspected static groundwater level.

Each well screen was sealed at the bottom using a threaded cap and each riser was sealed at the top
with a lockable J-plug cap. Silica sand was placed around and above the screened interval to form a filter
pack around the well screen. A layer of bentonite was placed above the silica sand and was extended to
the ground surface. Protective aboveground monument casings were installed at the ground surface over
riser pipes and tamped in place.

The locations of the monitoring wells are shown on Figures 2 and 3. The monitoring well construction
details are shown on the borehole logs included in Appendix II and on Table 1 in Appendix III (all Tables
are provided within Appendix III).

© 2021 Pinchin Ltd.                                                                                       Page 3 of 12
Phase II Environmental Site Assessment                                                    January 8, 2021
             85 York Road West, Yorkton, Saskatchewan                                          Pinchin File: 284505.001
             Alvarez & Marsal Canada Inc., in its capacity as Monitor of Contour Realty Inc.

2.3      Groundwater Monitoring

The water levels within the monitoring wells were measured on December 14, 2020 using an interface
probe. The presence/absence of non-aqueous phase liquid (NAPL) was also assessed during
groundwater monitoring using the interface probe.

2.4      Sampling and Laboratory Analysis

2.4.1    Soil

The most apparent “worst case” soil sample from each borehole (two samples total), based on vapour
concentrations as well as visual and/or olfactory considerations, groundwater depths and contaminant
characteristics, were submitted for laboratory analysis of BTEX, PHC F1 to F4, VOCs, PAHs and/or total
lead.

In addition, representative soil samples were submitted for particle size analysis (PSA) for regulatory
classification purposes. A composite sample of the excess soil generated by the borehole drilling program
was also submitted for landfill characterization analysis (leachable benzene, total toluene, ethylbenzene
and xylenes, leachable metals, paint filter, pH and flashpoint) in accordance with Transport Canada’s
Transportation of Dangerous Goods Act, 1992, current to December 2020, (hereafter referred to as the
TDG) to characterize the soil cuttings for possible off-Site disposal purposes.

The borehole locations are shown on Figures 2 and 3.

2.4.2    Groundwater

On December 11, 2020, the newly installed groundwater monitoring well (MW20-02) was developed by
purging groundwater until dry in accordance with Pinchin SOPs. Pinchin notes the other newly installed
groundwater monitoring well (MW20-01) had insufficient groundwater volume to develop, and therefore
could not be developed on December 11, 2020.

As a result of slow groundwater recovery and Client time restrictions, on December 14, 2020, the
groundwater monitoring wells MW20-01 and MW20-02 were sampled prior to purging until dry, and
submitted for laboratory analysis of BTEX, PHC F1 and F2, VOCs, PAHs and/or total lead.

All monitoring well development, purging and sampling activities were conducted using dedicated inertial
pumps comprised of Waterra polyethylene tubing and foot valves to draw groundwater to the surface.

The monitoring well locations are shown on Figure 2 and 3. Table 2 provides a summary of the
groundwater samples submitted for laboratory analysis.

© 2021 Pinchin Ltd.                                                                                       Page 4 of 12
Phase II Environmental Site Assessment                                                    January 8, 2021
             85 York Road West, Yorkton, Saskatchewan                                          Pinchin File: 284505.001
             Alvarez & Marsal Canada Inc., in its capacity as Monitor of Contour Realty Inc.

2.4.3    Analytical Laboratory

Selected soil and groundwater were delivered to Bureau Veritas Laboratories (BV Labs) in Calgary,
Alberta for analysis. BV Labs is an independent laboratory accredited by the Standards Council of
Canada and the Canadian Association for Laboratory Accreditation. Formal chain of custody records of
the sample submissions were maintained between Pinchin and BV Labs.

2.5      QA/QC Protocols

Various quality assurance/quality control (QA/QC) protocols were followed during the Phase II ESA to
ensure that representative samples were obtained and that representative analytical data was reported by
the laboratory.

Field QA/QC protocols that were employed by Pinchin included the following:

         •            Care was exercised not to obtain soil samples that were in direct contact with the drilling
                      equipment or that had been smeared along the edge of the borehole;

         •            Soil and groundwater samples were placed in laboratory-supplied containers with
                      preservatives added where required;

         •            The monitoring wells were developed, when possible, following installation. Dedicated
                      purging and sampling equipment was used for monitoring well development and
                      sampling to minimize the potential for cross-contamination;

         •            Soil and groundwater samples were placed in ice chilled coolers ice immediately upon
                      collection, with appropriate sample temperatures maintained prior to submission to the
                      laboratory;

         •            Dedicated and disposable nitrile gloves were used for sample handling;

         •            Non-dedicated monitoring and sampling equipment (e.g. interface probe, putty knife, etc.)
                      was cleaned before initial use and between uses to minimize the potential for cross-
                      contamination by washing with an Alconox™/potable water mixture followed by a
                      deionized water rinse; and

         •            Sample collection and handling procedures were performed in general accordance with
                      Pinchin SOPs utilized for Phase II ESAs.

BV Labs’ internal laboratory QA/QC consisted of the analysis of laboratory duplicate, method blank,
matrix spike and spiked blank samples, an evaluation of relative percent difference calculations for
laboratory duplicate samples, and an evaluation of surrogate recoveries.

© 2021 Pinchin Ltd.                                                                                       Page 5 of 12
Phase II Environmental Site Assessment                                                    January 8, 2021
             85 York Road West, Yorkton, Saskatchewan                                          Pinchin File: 284505.001
             Alvarez & Marsal Canada Inc., in its capacity as Monitor of Contour Realty Inc.

2.6      Regulatory Criteria

Environmental matters pertaining to contaminated sites in Saskatchewan fall under the jurisdiction of the
Saskatchewan Ministry of Environment (MOE). Therefore, the Site is subject to the MOE Saskatchewan
Environmental Quality Standards, dated 2015 (SEQS). In order to assess sites in Saskatchewan, the
MOE utilizes tiered endpoints, which are intended to be protective of human health and the environment.

The Tier 1 SEQS represent the lowest criteria value for any given constituent of concern with all receptors
and exposure pathways applicable to the Site and surrounding land use taken into consideration.
Consequently, the generic Tier 1 SEQS are applicable for all sites.

The Tier 2 SEQS is specific to intended exposure scenarios and includes the exclusion of specific
receptors and exposure pathways deemed inapplicable to Site and surrounding land use while the Tier 3
SEQS includes risk assessment or the development of site-specific guidelines.

For landfill waste characterization purposes, analytical results were compared to the TDG. Although the
TDG has been repealed and amended, the waste characterization limits specific to the 2002 version of
the TDG remain in use for Saskatchewan-based disposal facilities in determining the acceptance of waste
soils.

A land use and exposure pathway assessment was completed for the Site in order to utilize the most
appropriate regulatory criteria. This assessment included an evaluation of land use for the Site and
surrounding properties, receptors at risk, exposure pathways and soil texture. The following table
summarizes the results of the land use assessment:

 Background Information               Description
 Registered Owner                     Contour Realty Inc.

 Site Description                     Civic Address: 85 York Road West, Yorkton, Saskatchewan.
                                      Legal Land Location: Blk/Par Z-Plan 67Y09629 Ext 0, Lots 15 and 16-
                                      Blk/Par 9-Plan 00Y00664 Ext 0.
                                      Area: 4.6 hectares (11.37 acres).
 On-site Infrastructure               A large single-storey industrial building with a second-storey office
                                      space.
 Land Use and Zoning                  Industrial.
 Surrounding Land Use                 North – Railway line/spur lines and vacant land followed by light
 (within 30 metres of all             industrial development.
 property lines of Site)              South – York Road West followed by residential development.
                                      West – Industrial Avenue followed by light industrial development.
                                      East – Vacant industrial.

© 2021 Pinchin Ltd.                                                                                       Page 6 of 12
Phase II Environmental Site Assessment                                                    January 8, 2021
             85 York Road West, Yorkton, Saskatchewan                                          Pinchin File: 284505.001
             Alvarez & Marsal Canada Inc., in its capacity as Monitor of Contour Realty Inc.

 Background Information               Description
 Subsurface Materials                 PSA analysis on two soil samples from the Site indicated that the soil
                                      profile at the Site is predominantly fine-grained.

 Surface Water                        Not applicable: The nearest surface water body is a large pond located
                                      approximately 900 metres southwest of the Site. As there are no surface
                                      water bodies located within 500 metres of the Site, the freshwater
                                      aquatic life exposure pathway can be excluded.

 Groundwater                          Not applicable: According to the Water Security Agency’s (WSA) online
                                      database, there are no groundwater wells used for domestic potable use
                                      within 500 m of the Site. In addition, the Site and surrounding properties
                                      are located within city limits with potable water supplied by the City of
                                      Yorkton via the municipal water service. A water well registered for
                                      “domestic withdrawal” is located approximately 450 m west of the Site;
                                      however, based on a telephone conservation with an employee at the
                                      commercial property (McMunn & Yates Building Supplies) where the
                                      water well is located, groundwater from the well is not used for domestic
                                      uses, rather the well is used to lower the water level in a nearby dugout
                                      and the surrounding groundwater table to mitigate surficial wet/soft soil
                                      conditions on the property. The recovered groundwater is transferred for
                                      discharge into the municipal sewer service. The WSA database search
                                      also provided record of a water test hole that was not completed as a
                                      well. Copies of the water well reports are included in Appendix V.

 Vapour Inhalation Potential          Applicable: Potential vapour migration through potential future building
                                      slabs.

 Ecological Soil Contact              Applicable: In the event of excavation activities on-Site and potential off-
                                      Site migration of soil and/or dust.

 Soil Ingestion                       Applicable: In the event of excavation activities on-Site.

 Dermal Contact                       Applicable: In the event of excavation activities on-Site.

 Off-Site Migration Potential         Applicable: Impacts appear to have migrated on-Site from the
                                      neighboring property to the east.

 Other Environmental                  Not applicable.
 Considerations

 Future Land Use                      Unchanged based on zoning.

Two soil samples collected from different borehole locations and depths of 3.81 and 5.33 mbgs were
submitted for PSA. The PSA results indicated that between 43% and 1.1% of the soil by weight was
retained on a 75 micron sieve, indicating the soil profile encountered on-Site was predominantly fine-
grained.

© 2021 Pinchin Ltd.                                                                                       Page 7 of 12
Phase II Environmental Site Assessment                                                    January 8, 2021
             85 York Road West, Yorkton, Saskatchewan                                          Pinchin File: 284505.001
             Alvarez & Marsal Canada Inc., in its capacity as Monitor of Contour Realty Inc.

Soil and groundwater at the Site was evaluated from a Tier 2 SEQS perspective, where each receptor
and exposure pathway was evaluated to determine their applicability/inapplicability to the Site and off-Site
property. As there are no water bodies or suspected domestic/municipal water wells within 500 m of the
Site, the Site and surrounding area are within the municipal boundaries of Yorkton and are supplied with
treated drinking water supplied by the municipal water service, the freshwater aquatic life and potable
groundwater exposure pathways were determined to be inapplicable to the Site.

Based on the Site and surrounding land use, proximity to water bodies, nearby water well use and
underlying fine-grained soil profile, the soil and groundwater quality at the Site was compared to the Tier
2 SEQS, specifically those standards for industrial land use and a fine-grained soil profile, with freshwater
aquatic life and potable groundwater excluded from consideration as applicable exposure pathways
(hereafter referred to as the Tier 2 SEQS).

3.0      RESULTS

3.1      Site Geology and Hydrogeology

Based on the soil samples recovered during the borehole drilling program, the soil profile at the drilling
locations generally consists of topsoil to depths of approximately 0.38 and 0.46 mbgs, followed by native
silt, clay, silty clay and silty clay till that extended to the maximum borehole completion depth of 6.10
mbgs. Wet soil conditions were generally observed between 1.8 and 4.6 mbgs.

A detailed description of the soil profile encountered during borehole advancement is documented in the
borehole logs located in Appendix II.

The water level information obtained during groundwater monitoring is presented in Table 1 and on the
borehole logs in Appendix II. On December 14, 2020, the depth to groundwater measured within the
monitoring wells ranged from 3.85 mbgs at monitoring well MW20-02 to 4.06 mbgs at monitoring well
MW20-01.

Pinchin notes that two previously installed monitoring wells installed by PMEL were observed to be
damaged and were not viable to collect groundwater samples from. The locations of the pre-existing
monitoring wells are shown in Figure 3.

A large pond is located approximately 900 m southwest of the Site. Based on this observation, Pinchin
infers that groundwater flow at the Site is towards the southwest.

3.2      Soil Headspace Vapour Concentrations

The vapour concentrations measured in the headspace of soil samples collected and field-screened
during the drilling investigation are presented on the borehole logs in Appendix II. The VOC derived

© 2021 Pinchin Ltd.                                                                                       Page 8 of 12
Phase II Environmental Site Assessment                                                    January 8, 2021
             85 York Road West, Yorkton, Saskatchewan                                          Pinchin File: 284505.001
             Alvarez & Marsal Canada Inc., in its capacity as Monitor of Contour Realty Inc.

concentration were all 0 parts per million by volume (ppmv). The PHC derived vapour concentrations
ranged from a minimum concentration of 25 ppmv in soil sample MW20-02 @ 5, collected from borehole
MW20-02 at a depth of 1.52 mbgs to a maximum concentration of 990 ppmv measured in soil sample
MW20-01 @ 12.5 collected from borehole MW20-01 at a depth of 3.81 mbgs.

3.3      Field Observations

No odours or staining were observed in the soil samples collected during the borehole drilling program.

No odours or evidence of NAPL were observed during groundwater monitoring and sampling.

3.4      Analytical

3.4.1    Soil

As indicated in Tables 3 through 5, the reported concentrations of BTEX, PHC F1 to F4, VOCs, PAHs
and total lead in the soil samples submitted for analysis were compliant with the Tier 2 SEQS.

The analytical results of the sample analyzed for landfill characterisation parameters are summarised in
Table 6. The parameters were below the applicable regulatory criteria and the soil cuttings were classified
as non-hazardous and suitable for transport and disposal at a Class II landfill facility.

The laboratory Certificate of Analysis for the soil samples is provided in Appendix IV.

3.4.2    Groundwater

As indicated in Tables 7 through 9, the reported concentrations of BTEX, PHC F1 and F2, VOCs, PAHs
and total lead in the groundwater samples submitted for analysis were compliant with the Tier 2 SEQS.

It should be noted that benzene and/or toluene concentrations in the groundwater samples submitted for
laboratory analysis exceeded the MOE Discharge and Discovery Reporting Standards, dated October 1,
2017 (DDRS) and as stated in the DDRS, any concentrations exceeding these limits will need to be
reported to the MOE.

The laboratory Certificate of Analysis for the groundwater samples is provided in Appendix IV.

4.0      FINDINGS AND CONCLUSIONS

Based on the work completed, the following is a summary of the activities and findings of this Phase II
ESA:

         •            Pinchin retained Maple Leaf Drilling Ltd. to advance two boreholes (MW20-01 and
                      MW20-02) at the Site on December 10, 2020. The boreholes were advanced to a

© 2021 Pinchin Ltd.                                                                                       Page 9 of 12
Phase II Environmental Site Assessment                                                      January 8, 2021
             85 York Road West, Yorkton, Saskatchewan                                            Pinchin File: 284505.001
             Alvarez & Marsal Canada Inc., in its capacity as Monitor of Contour Realty Inc.

                      maximum depth of 6.10 mbgs using a track-mounted drill rig. Both of the boreholes were
                      instrumented with monitoring wells to enable groundwater monitoring and sampling.

         •            The soil profile at the drilling locations generally consists of topsoil to depths of
                      approximately 0.38 and 0.46 mbgs, followed by native silt, clay, silty clay and silty clay till
                      that extended to the maximum borehole completion depth of 6.10 mbgs. Wet soil
                      conditions were generally observed between 1.8 and 4.6 mbgs.

         •            On December 14, 2020, the depth to groundwater measured within the monitoring wells
                      ranged from 3.85 mbgs at monitoring well MW20-02 to 4.06 mbgs at monitoring well
                      MW20-01. A large pond is located approximately 900 m southwest of the Site. Based on
                      this observation, Pinchin infers that groundwater flow at the Site is towards the
                      southwest.

         •            The “worst case” soil samples collected from each borehole were submitted for laboratory
                      analysis BTEX, PHC F1 to F4, VOCs, PAHs and/or total lead. Groundwater samples
                      collected from the newly installed monitoring wells were submitted for laboratory analysis
                      of BTEX, PHC F1 and F2, VOCs, PAHs and/or total lead.

         •            Based on the Site and surrounding land use, proximity to water bodies, nearby water well
                      use and underlying fine-grained soil profile, the soil and groundwater quality at the Site
                      was compared to the Tier 2 SEQS, specifically those standards for industrial land use
                      and a fine-grained soil profile, with freshwater aquatic life and potable groundwater
                      excluded from consideration as applicable exposure pathways (hereafter referred to as
                      the Tier 2 SEQS).

         •            The reported concentrations of BTEX, PHC F1 to F4, VOCs, PAHs and total lead in the
                      soil samples submitted for analysis were all compliant with the Tier 2 SEQS. The
                      reported concentrations of BTEX, PHC F1 and F2, VOCs, PAHs and total lead in the
                      groundwater samples submitted for analysis were also found to be compliant with the
                      Tier 2 SEQS.

Based on the findings of this Phase II ESA, it is Pinchin’s opinion that no further subsurface investigation
is required for the Site in relation to the findings of the previous investigations at this time.

It should be noted that benzene and/or toluene concentrations in the groundwater samples submitted for
laboratory analysis exceeded the MOE DDRS and as stated in the DDRS, any concentrations exceeding
these limits will need to be reported to the MOE.

© 2021 Pinchin Ltd.                                                                                        Page 10 of 12
Phase II Environmental Site Assessment                                                    January 8, 2021
             85 York Road West, Yorkton, Saskatchewan                                          Pinchin File: 284505.001
             Alvarez & Marsal Canada Inc., in its capacity as Monitor of Contour Realty Inc.

Pinchin will submit a historical discovery report to the MOE under separate cover. Pinchin recommends
that the adjacent property owner to the east be notified of the MOE DDRS exceedances which appear to
have resulted from the former fueling station that was located on this property.

5.0      TERMS AND LIMITATIONS

This Phase II ESA was performed for Alvarez & Marsal Canada Inc., in its capacity as Monitor of
101098672 Saskatchewan Ltd., Morris Industries Lt., Morris Sales and Service Ltd., Contour Realty Inc.,
and Morris Industries (US) Inc., and not its personal or corporate capacity (Client) in order to investigate
potential environmental impacts at 85 York Road West, in Yorkton, Saskatchewan (Site). The term
recognized environmental condition means the presence or likely presence of any hazardous substance
on a property under conditions that indicate an existing release, past release, or a material threat of a
release of a hazardous substance into structures on the property or into the ground, groundwater, or
surface water of the property. This Phase II ESA does not quantify the extent of the current and/or
recognized environmental condition or the cost of any remediation.

Conclusions derived are specific to the immediate area of study and cannot be extrapolated extensively
away from sample locations. Samples have been analyzed for a limited number of contaminants that are
expected to be present at the Site, and the absence of information relating to a specific contaminant does
not indicate that it is not present.

No environmental site assessment can wholly eliminate uncertainty regarding the potential for recognized
environmental conditions on a property. Performance of this Phase II ESA to the standards established
by Pinchin is intended to reduce, but not eliminate, uncertainty regarding the potential for recognized
environmental conditions on the Site and recognizes reasonable limits on time and cost.

This Phase II ESA was performed in general compliance with currently acceptable practices for
environmental site investigations, and specific Client requests, as applicable to this Site. The scope of
work completed by Pinchin, as part of this Phase II ESA, is not sufficient (in and of itself) to meet the
provincial requirements for a Phase II ESA. If the report is expected to be sent to the MOE, or is sent to
the MOE through any other means, further consultation and/or work will be required.

This report was prepared for the exclusive use of the Client, subject to the terms, conditions and
limitations contained within the duly authorized proposal for this project. Any use which a third party
makes of this report, or any reliance on or decisions to be made based on it, is the sole responsibility of
such third parties. Pinchin accepts no responsibility for damages suffered by any third party as a result of
decisions made or actions conducted.

© 2021 Pinchin Ltd.                                                                                      Page 11 of 12
Phase II Environmental Site Assessment                                                                                   January 8, 2021
                 85 York Road West, Yorkton, Saskatchewan                                                                         Pinchin File: 284505.001
                 Alvarez & Marsal Canada Inc., in its capacity as Monitor of Contour Realty Inc.

If additional parties require reliance on this report, written authorization from Pinchin will be required.
Pinchin disclaims responsibility of consequential financial effects on transactions or property values, or
requirements for follow-up actions and costs. No other warranties are implied or expressed. Furthermore,
this report should not be construed as legal advice. Pinchin will not provide results or information to any
party unless disclosure by Pinchin is required by law.

Pinchin makes no other representations whatsoever, including those concerning the legal significance of
its findings, or as to other legal matters touched on in this report, including, but not limited to, ownership
of any property, or the application of any law to the facts set forth herein. With respect to regulatory
compliance issues, regulatory statutes are subject to interpretation and these interpretations may change
over time.
\\fsrmd\job\284000s\0284505.000 Alvarez&Marsal;85YorkRd,Yorkton;EDR;PhI\0284505.001 Alvarez&Marsal;85YorkRd,Yorkton;EDR,PhII\Deliverables\284505.001 Phase II
ESA Report 85 York Rd West Yorkton SK_A&M_January 8, 2021.docx

Template: Master Report for Phase II ESA - Stage 2 PSI, EDR, August 20, 2020

© 2021 Pinchin Ltd.                                                                                                                            Page 12 of 12
APPENDIX I
   Figures
´

                                               0     1
                                                     00       2
                                                              00   3
                                                                   00   4
                                                                        00   5
                                                                             00   6
                                                                                  00   7
                                                                                       00   8
                                                                                            00

                                                                        m
P
R O
  JECTN
      AME
        :
                                  P
                                  H A
                                    SEIIE
                                        N V
                                          IRON
                                             M E
                                               N T
                                                 A LS
                                                    ITEA
                                                       SSE
                                                         SSME
                                                            N T
C
LIE
  N TN
     AME
       :
                                         ALVAREZ & MARSAL CANADA INC.
P
R O
  JECTL
      O C
        ATIO
           N:
                                8
                                5YOR
                                   KROA
                                      DWE
                                        ST,Y
                                           O R
                                             KTON
                                                ,SA
                                                  SKA
                                                    TCH
                                                      EWA
                                                        N
F
IGU
  REN
    AME
      :                                                                             F
                                                                                    IGU
                                                                                      REN
                                                                                        UMB
                                                                                          ER
                                                    K
                                                    EYM
                                                      AP
P
R O
  JECTN
      UMB
        ER:     S
                C A
                  LE:           D
                                RAWNB
                                    Y:             R
                                                   EVIE
                                                      W E
                                                        DBY
                                                          :         D
                                                                    ATE:                       1
    2
    845
      05.0
         01             1
                        :20
                          ,00
                            0            E
                                         K                C
                                                          L             J
                                                                        A N
                                                                          UARY2
                                                                              021
N
                                                                                                                            LEGEND

                                                                                                                                     SITE BOUNDARY

                                                                                                                                     SITE BUILDING

                                                                                                                                     MONITORING WELL

                                                                                                                                     AREA OF POTENTIAL
                                                                                                                                     ENVIRONMENTAL CONCERN (APEC)
              LIGHT
           INDUSTRIAL                                                                                                                RAILWAY LINE

                            INDUSTRIAL AVENUE

                                                                       MW20-01

                                                                       MW20-02
                                                                                           OLD
                                                                                         FUELING
                                                                                          AREA
                                                                                                                VACANT
                                                                                                              INDUSTRIAL
             LIGHT
          INDUSTRIAL

                                                                                                                            LEGEND IS COLOUR DEPENDENT
                                                                                                                            NON-COLOUR COPIES SHOULD NOT BE
                                                                                                                            USED FOR INTERPRETATION

                                                                                                                            PROJECT NAME:

                                                                                                                                    PHASE II ENVIRONMENTAL
                                                                                                                                       SITE ASSESSMENT

                                                                                                                            CLIENT NAME:

                                                      YORK ROAD WEST    YORK ROAD WEST                                                  ALVAREZ & MARSAL
                                                                                                                                           CANADA INC.

                                                                                                                            PROJECT LOCATION:

                                                                                                                                  85 YORK ROAD WEST
                                                                                                                                YORKTON, SASKATCHEWAN

                                                                                                                            FIGURE NAME:

                                                                                                                                  SITE PLAN WITH NEW
                                                RES                                                     RES                   MONITORING WELL LOCATIONS

                                                                                                                            PROJECT NUMBER:          SCALE:
                                                                                                                                284505.001             AS SHOWN
                                                                                                                            DRAWN BY:                REVIEWED BY:

                                                                        INFERRED                                            E.KOURNOSSOV                 C.LEASK
                                                                                          0        20    40           80m
                                                                        GROUNDWATER                                         DATE:                    FIGURE NUMBER:
©Google Maps contributors                                               FLOW DIRECTION
                                                                                                                              JANUARY 2021                    2
N
                                                                            LEGEND

                                                                                     SITE BOUNDARY

                                                                                     DAMAGED MONITORING WELL

                                                                                     MONITORING WELL

                                                                                     AREA OF POTENTIAL
                                                                                     ENVIRONMENTAL CONCERN (APEC)

                                                                                     RAILWAY LINE

                            MW20-01

                            MW20-02

                                      OLD FUELING
                                         AREA

                                                      VACANT
                                                    INDUSTRIAL

                                                                            LEGEND IS COLOUR DEPENDENT
                                                                            NON-COLOUR COPIES SHOULD NOT BE
                                                                            USED FOR INTERPRETATION

                                                                            PROJECT NAME:

                                                                                    PHASE II ENVIRONMENTAL
                                                                                       SITE ASSESSMENT

                                                                            CLIENT NAME:

                                                                                        ALVAREZ & MARSAL
                                                                                           CANADA INC.

                                                                            PROJECT LOCATION:

                                                                                  85 YORK ROAD WEST
                                                                                YORKTON, SASKATCHEWAN

                                                                            FIGURE NAME:

                                                                               BOREHOLE AND MONITORING
                                                                                  WELL LOCATION PLAN

                                                                            PROJECT NUMBER:         SCALE:
                                                                                284505.001            AS SHOWN
                                                                            DRAWN BY:               REVIEWED BY:
                                                                            E.KOURNOSSOV                C.LEASK
                                                       0   5     10   20m
                                                                            DATE:                   FIGURE NUMBER:
©Google Maps contributors                                                     JANUARY 2021                   3
APPENDIX II
Borehole Logs
Log of Borehole: MW20-01
                                                                Proj ect #: 284505.001                                                                               Logged By: Cody Leask
                                                                Proj ect: Phase II Environmental Site Assessment
                                                                Client: Alvarez & Marsal Canada Inc.
                                                                Location: 85 York Road West, Yorkton, Saskatchewan
                                                                Drill Date: December 10, 2020
                                  SUBSURFACE PROFILE                                                                                                                  SAMPLE

                                                                                                                                                                       Concentration
                                                                                                                                        Recovery (%)
                                                                                                   Well Details

                                                                                                                                                                       Soil Vapour

                                                                                                                                                                                           Laboratory
                                                                                                                                                         Sample ID
                                                                                                   Monitoring
                                                                         Depth (m)
                                                                         Measured
                                          Description

                                                                                                                                                                       CGI/PID

                                                                                                                                                                                           Analysis
                 Symbol
     Depth

                                                                                                                                                                       (ppm)
 ft m

                                                                                                                  Protective Stick-Up
                                                                                     Silica Sand
                                        Ground Surface                   0.00
0            0
                          Topsoil
1                         Light Black TOPSOIL, some organics,            0.46
2                         moist, firm
                                                                                                                                        100                               35/0
3                         Silt
                                                                                     Bentonite

             1
4                         Brown SILT, trace clay, moist, firm
                          @ 1.15 mbgs - some clay, very moist,
                                                                                                                  Riser
5                         soft                                                                                                          100                               30/0
                                                                         1.83
6
             2            Clay
7                         Brown CLAY, some silt, trace coal,                                                                            100                               40/0
                                                                                     Silica Sand

 8                        slightly wet, soft
                                                                         2.74
 9
                          Silty Clay
10           3                                                                                                                          100                               30/0
                          Brown SILTY CLAY (TILL) trace coal,
11                        oxides and pebbles, slightly wet, firm
12                        @ 3.05 mbgs - moist                                                                                                                                          BTEX, PHC F1
                                                                                                                                                       MW20-01
                                                                                     Screen

                                                                                                                                        100                              990/0          to F4, VOCs
13           4                                                                                                                                         @ 12.5
                          @ 3.96 to 4.57 mbgs - sand and                                                                                                                               and Total Lead
14                        pebble lenses, wet
                                                                                                                  Water Level

15                                                                                                                                      100                               35/0
                          @ 4.57 mbgs - grey, hard
16
             5
17
                                                                                                                                        100                              540/0
18
                                                                                     Bentonite

19
             6                                                           6.10                                                           100                              310/0
20
                                       End of Borehole
21
22                        Soil vapour concentrations measured using
                          a RKI Eagle 2 equipped with a
23           7            photoionization detector (PID) and a
                          combustible gas indicator (CGI).
24

     Contractor: Maple Leaf Drilling                                                                          Grade Elevation: N/A

     Drilling Method: Solid Stem                                                                              Top of Casing Elevation: N/A

     Well Casing Size: 5.08 cm                                                                                Sheet: 1 of 1
Log of Borehole: MW20-02
                                                                Proj ect #: 284505.001                                                                               Logged By: Cody Leask
                                                                Proj ect: Phase II Environmental Site Assessment
                                                                Client: Alvarez & Marsal Canada Inc.
                                                                Location: 85 York Road West, Yorkton, Saskatchewan
                                                                Drill Date: December 10, 2020
                                  SUBSURFACE PROFILE                                                                                                                  SAMPLE

                                                                                                                                                                       Concentration
                                                                                                                                        Recovery (%)
                                                                                                   Well Details

                                                                                                                                                                       Soil Vapour

                                                                                                                                                                                           Laboratory
                                                                                                                                                         Sample ID
                                                                                                   Monitoring
                                                                         Depth (m)
                                                                         Measured
                                          Description

                                                                                                                                                                       CGI/PID

                                                                                                                                                                                           Analysis
                 Symbol
     Depth

                                                                                                                                                                       (ppm)
 ft m

                                                                                                                  Protective Stick-Up
                                                                                     Silica Sand
                                        Ground Surface                   0.00
 0           0
                          TopSoil                                        0.38
 1                        Light Black TOPSOIL, some organics,
 2                        moist, firm
                                                                                                                                        100                               45/0
 3           1            Silt
                                                                                     Bentonite

 4                        Brown SILT, trace clay, coal and
 5                        oxides, grey mottling, moist, firm                                                                            100                               25/0
                          @ 1.14 mbgs - some clay, trace
                                                                                                                  Riser

 6
             2            pebbles
 7                        @ 1.67 mbgs - no trace pebbles                                                                                100                              115/0
 8                        @ 2.43 mbgs - very moist, soft
 9
                                                                                     Silica Sand

                                                                                                                  Screen

10           3                                                                                                                          100                               60/0
11
                                                                         3.66
12
                          Silty Clay                                                                                                    100                              370/0
13           4
                                                                                                                  Water Level

                          Brown SILTY CLAY, trace sand, coal
14                        and pebbles, very moist, soft
15                        @ 3.96 mbgs - sand lenses, wet                                                                                100                              145/0
                          @ 4.42 mbgs - light brown, trace               4.88
16                                                                                                                                                                                     BTEX, PHC F1
             5            oxides, very moist, firm, no trace coal
17                        and pebbles                                                                                                                  MW20-02                          to F4, PAHs,
                                                                                                                                        100                              480/0
18                                                                                                                                                     @ 17.5                          VOCs and Total
                          Silty Clay                                                                                                                                                        Lead
19                        Brown SILTY CLAY, grey mottling,
             6                                                           6.10                                                           100                              130/0
                                                                                                                  Bentonite

20                        moist, stiff
21                        @ 5.48 mbgs - hard
22                                     End of Borehole
23           7
                          Soil vapour concentrations measured using
24                        a RKI Eagle 2 equipped with a
25                        photoionization detector (PID) and a
                          combustible gas indicator (CGI).
26           8

     Contractor: Maple Leaf Drilling                                                                          Grade Elevation: N/A

     Drilling Method: Solid Stem                                                                              Top of Casing Elevation: N/A

     Well Casing Size: 5.08 cm                                                                                Sheet: 1 of 1
APPENDIX III
Summary Tables
TABLE 1
                           MONITORING WELL CONSTRUCTION AND GROUNDWATER MONITORING DETAILS
                                                 Alvarez & Marsal Canada Inc.
                                          85 York Road West, Yorkton, Saskatchewan
  0.848
                                                                                                                   Distance
                                                                                                                   Between
                                             Date Groundwater           NAPL Level             Water Level          Ground      Total Depth                  Depth to
                                                Monitoring             Measurement            Measurement         Surface and   of Well from   Length of   Groundwater
                        Date Drilled            Completed                from TOC               from TOC             TOC a          TOC         Screen     Below-Grade
   Well Number        (dd-mmm-yyyy)           (dd-mmm-yyyy)                 (m)                    (m)                (m)           (m)           (m)        (mbgs)

         MW20-01         10-Dec-20                14-Dec-20                   ND                    5.08             -1.02         5.870         3.05          4.06
         MW20-02         10-Dec-20                14-Dec-20                   ND                    4.77             -0.92         6.045         3.05          3.85

Notes:
             NAPL   Non-Aqueous Phase Liquid
             TOC    Top of casing
              m     Metres
             mbgs   Metres below ground surface
               a    Positive number indicate a TOC below-grade, and negative numbers indicate a TOC above-grade
              ND    Not detected

                                                                                                                                                   Pinchin File: 284505.001
TABLE 2
         SAMPLES SUBMITTED FOR LABORATORY ANALYSIS AND PARTICLE SIZE ANALYSIS
                                Alvarez & Marsal Canada Inc.
                         85 York Road West, Yorkton, Saskatchewan

                  Samples                                                                                                     Parameters

                                                                                                                              Class II Landfill
                                                                     PHCs (F1-F4) &

                                                                                                                                                                        PHCs (F1-F2) &

                                                                                                                                                                                                                                          Sieve - #200
                                                                                                                                                                                                                                          (>0.075mm)
                                     Sample

                                                                                                                                                  GROUNDWATER SAMPLES

                                                                                                                                                                                                                                                         Grain Size
                                                                                                    Total Lead

                                                                                                                                                                                                       Total Lead
                                                                                                                 Grain Size
 Borehole /                           Depth

                                                                                                                 Analysis

                                                                                                                                                                                                                    SOIL TEXTURE (PSA)
 Monitoring                          Range

                                                                                      VOCs

                                                                                                                                                                                         VOCs
                                                                     BTEX

                                                                                                                                                                        BTEX
                                                                                             PAHs

                                                                                                                                                                                                PAHs
                                                      SOIL SAMPLES
  Well ID         Sample ID          (mbgs)
                   MW20-01               NA                                                                                                                                ● ●                         ●
   MW20-01
                MW20-01 @ 12.5          3.81                            ●             ● ● ● ●                                                                                                                                               43            F

                   MW20-02               NA                                                                                                                                ● ● ● ●
   MW20-02
                MW20-02 @ 17.5          5.33                            ●             ●             ● ●                                                                                                                                     1.1           F

         N/A        Landfill        Composite                                                                                 ●
Notes:
                       ●         Sample was submitted for laboratory analysis of the indicated parameter
                  PHCs (F1-F4)   Petroleum hydrocarbon fractions: F1 (C6 – C10), F2 (C>10 – C16), F3 (C>16 – C34), and F4 (C>34)
                  PHCs (F1-F2)   Petroleum hydrocarbon fractions: F1 (C6 – C10), F2 (C>10 – C16)
                     BTEX        Benzene, Toluene, Ethylbenzene, and Xylenes
                     VOCs        Volatile Organic Compounds
                     PAHs        Polycyclic Aromatic Hydrocarbons
                     mbgs        Metres below ground surface
                      NA         Not applicable

                                                                                                                                                                                                                                         Pinchin File: 284505.001
TABLE 3
               BTEX, PETROLEUM HYDROCARBON AND TOTAL LEAD ANALYSIS FOR SOIL
                                   Alvarez & Marsal Canada ULC
                           85 York Road West, Saskatoon, Saskatchewan

                                                                                                             Sample Designation
                                                                                                     Sample Collection Date (dd-mm-yyyy)
                                                                                                           Sample Depth (mbgs) a
          Parameter                        Tier 2 SEQS a                     DDRS
                                                                                                   MW20-01 @ 12.5                MW20-02 @ 17.5
                                                                                                     10-Dec-20                     10-Dec-20
                                                                                                        3.81                          5.33

Benzene                                           11                          0.046
TABLE 4
                             VOLATILE ORGANIC COMPOUND ANALYSIS FOR SOIL
                                        Alvarez & Marsal Canada Inc.
                                 85 York Road West, Yorkton, Saskatchewan

                                                                                                      Sample Designation
                                                                                               Sample Collection Date (dd/mmm/yy)
             Parameter                     Tier 2 SEQS                    DDRS                       Sample Depth (mbgs)
                                                                                               MW20-01 @ 12.5     MW20-02 @ 17.5
                                                                                                 10-Dec-20            10-Dec-20
                                                                                                    3.81                 5.33

Bromodichloromethane                              NS                          NS
TABLE 5
                       POLYCYCLIC AROMATIC HYDROCARBON ANALYSIS FOR SOIL
                                     Alvarez & Marsal Canada Inc.
                              85 York Road West, Yorkton, Saskatchewan

                                                                                                          Sample Designation
                                                                                                  Sample Collection Date (dd-mmm-yy)
                                                                                                         Sample Depth (mbgs)
            Parameter                            Tier 2 SEQS                   DDRS
                                                                                                               MW20-01 @ 12.5
                                                                                                                 10-Dec-20
                                                                                                                    3.81

NON-CARCINOGENIC PAHs
Acenaphthene                                         75000                       NS
TABLE 6
                       LANDFILL CHARACTERIZATION FOR SOIL
                              Alvarez & Marsal Canada Inc.
                       85 York Road West, Yorkton, Saskatchewan

                                                                            Sample Designation
                                                                     Sample Collection Date (dd-mmm-yy)
           Parameter                         Criteria a
                                                                                         Landfill
                                                                                        10-Dec-20

LEACHABLE METALS
Antimony                                         NS
TABLE 7
         BTEX, PETROLEUM HYDROCARBON AND TOTAL LEAD ANALYSIS FOR GROUNDWATER
                                  Alvarez & Marsal Canada Inc.
                           85 York Road West, Yorkton, Saskatchewan

                                                                                                            Sample Designation
                                                                                                     Sample Collection Date (dd-mmm-yy)
            Parameter                         Tier 2 SEQS                     DDRS
                                                                                                        MW20-01                     MW20-02
                                                                                                        14-Dec-20                   14-Dec-20

Benzene                                              19                        0.005                        0.019
TABLE 8
                     VOLATILE ORGANIC COMPOUND ANALYSIS FOR GROUNDWATER
                                      Alvarez & Marsal Canada Inc.
                               85 York Road West, Yorkton, Saskatchewan

                                                                                                       Sample Designation
             Parameter                     Tier 2 SEQS                     DDRS                 Sample Collection Date (dd/mmm/yy)
                                                                                                   MW20-01             MW20-02
                                                                                                   14-Dec-20          14-Dec-20

Total Trihalomethanes                             NS                         NS
TABLE 9
           POLYCYCLIC AROMATIC HYDROCARBON ANALYSIS FOR GROUNDWATER
                              Alvarez & Marsal Canada Inc.
                       85 York Road West, Yorkton, Saskatchewan

                                                                                                          Sample Designation
                                                                                                   Sample Collection Date (dd-mmm-yy)
               Parameter                             Tier 2 SEQS                DDRS
                                                                                                                   MW20-02
                                                                                                                   14-Dec-20

NON-CARCINOGENIC PAH
Acenaphthene                                               NS                      NS
APPENDIX IV
Laboratory Certificates of Analysis
Your Project #: 284505.001
                                                                                                                     Site Location: 85 YORK ROAD WEST, YORKTON, SK
                                                                                                                     Your C.O.C. #: M036933
                  Attention: CODY LEASK
                  Pinchin Ltd.
                  210 CARDINAL CRESCENT
                  SASKATOON, SK
                  CANADA       S7L 6H8
                                                                                                                                                             Report Date: 2020/12/22
                                                                                                                                                                  Report #: R2970232
                                                                                                                                                                     Version: 1 - Final

                                                                      CERTIFICATE OF ANALYSIS
BV LABS JOB #: C092325
Received: 2020/12/14, 10:14
Sample Matrix: Soil
# Samples Received: 3
                                                                                               Date               Date
Analyses                                                                        Quantity       Extracted          Analyzed         Laboratory Method      Analytical Method
BTEX/F1 by HS GC/MS/FID (MeOH extract) (1)                                         3           N/A                2020/12/16       AB SOP-00039           CCME CWS/EPA 8260d m
F1-BTEX                                                                            3           N/A                2020/12/17                              Auto Calc
BTEX in Leachates by HS GC/MS/FID (2)                                              1           2020/12/18         2020/12/19       AB SOP-00039           EPA 8260d m
CCME Hydrocarbons (F2-F4 in soil) (3)                                              2           2020/12/17         2020/12/17       AB SOP-00036           CCME PHC-CWS m
Flash Point                                                                        1           N/A                2020/12/16       AB SOP-00062           ASTM D3828-16a/ A m
ICPMS Metals on TCLP Leachate (2)                                                  1           2020/12/17         2020/12/18       AB SOP-00043           EPA 6020b R2 m
Moisture                                                                           3           N/A                2020/12/17       AB SOP-00002           CCME PHC-CWS m
Index of Additive Cancer Risk (4)                                                  1           N/A                2020/12/18                              Auto Calc
Benzo[a]pyrene Equivalency                                                         1           N/A                2020/12/18                              Auto Calc
PAH in Soil by GC/MS                                                               1           2020/12/17         2020/12/18       AB SOP-00036 / AB SOP- EPA 3540C/8270E m
                                                                                                                                   00003
Free Liquid (Paint filter)                                                            1        N/A        2020/12/16               AB SOP-00047           EPA 9095B R2 m
Lead                                                                                  2        2020/12/21 2020/12/21               AB SOP-00001 / AB SOP- EPA 6020b R2 m
                                                                                                                                   00043
TCLP pH Measurements                                                                  1        2020/12/17 2020/12/18               AB SOP-00006           SM 23 4500 H+B m
pH @25C (1:1 extract, solid waste)                                                    1        2020/12/18 2020/12/18               AB SOP-00033 / AB SOP- SM 23 4500 H+B m
                                                                                                                                   00006
Particle Size by Sieve (75 micron)                                                    2        N/A                2020/12/18                              Auto Calc
Particle Size by Sieve                                                                2        N/A                2020/12/18       AB SOP-00022           ASTM D6913-17 m
VOCs in Soil by HS GC/MS (Std List) (1)                                               2        N/A                2020/12/16       AB SOP-00056           EPA 5021a/8260d m

Remarks:
Bureau Veritas Laboratories are accredited to ISO/IEC 17025 for specific parameters on scopes of accreditation. Unless otherwise noted, procedures used
by BV Labs are based upon recognized Provincial, Federal or US method compendia such as CCME, MELCC, EPA, APHA.

All work recorded herein has been done in accordance with procedures and practices ordinarily exercised by professionals in BV Labs profession using
accepted testing methodologies, quality assurance and quality control procedures (except where otherwise agreed by the client and BV Labs in writing). All
data is in statistical control and has met quality control and method performance criteria unless otherwise noted. All method blanks are reported; unless
indicated otherwise, associated sample data are not blank corrected. Where applicable, unless otherwise noted, Measurement Uncertainty has not been
accounted for when stating conformity to the referenced standard.

BV Labs liability is limited to the actual cost of the requested analyses, unless otherwise agreed in writing. There is no other warranty expressed or implied.
BV Labs has been retained to provide analysis of samples provided by the Client using the testing methodology referenced in this report. Interpretation and
use of test results are the sole responsibility of the Client and are not within the scope of services provided by BV Labs, unless otherwise agreed in writing.

                                                                                          Page 1 of 24
                                      Bureau Veritas Laboratories Calgary: 2021 - 41st Avenue N.E. T2E 6P2   Telephone (403) 291-3077   Fax (403) 291-9468
Your Project #: 284505.001
                                                                                                                          Site Location: 85 YORK ROAD WEST, YORKTON, SK
                                                                                                                          Your C.O.C. #: M036933
                  Attention: CODY LEASK
                  Pinchin Ltd.
                  210 CARDINAL CRESCENT
                  SASKATOON, SK
                  CANADA       S7L 6H8
                                                                                                                                                                  Report Date: 2020/12/22
                                                                                                                                                                       Report #: R2970232
                                                                                                                                                                          Version: 1 - Final

                                                                           CERTIFICATE OF ANALYSIS
BV LABS JOB #: C092325
Received: 2020/12/14, 10:14
BV Labs is not responsible for the accuracy or any data impacts, that result from the information provided by the customer or their agent.

Solid sample results, except biota, are based on dry weight unless otherwise indicated. Organic analyses are not recovery corrected except for isotope
dilution methods.
Results relate to samples tested. When sampling is not conducted by BV Labs, results relate to the supplied samples tested.
This Certificate shall not be reproduced except in full, without the written approval of the laboratory.
Reference Method suffix “m” indicates test methods incorporate validated modifications from specific reference methods to improve performance.
* RPDs calculated using raw data. The rounding of final results may result in the apparent difference.
(1) No lab extraction date is given for F1BTEX & VOC samples that are field preserved with methanol. Extraction date is date sampled unless otherwise stated.
(2) Samples were extracted as per EPA 1311 unless otherwise noted in the report.
(3) All CCME results met required criteria unless otherwise stated in the report. The CWS PHC methods employed by Bureau Veritas Laboratories conform to all prescribed elements
of the reference method and performance based elements have been validated. All modifications have been validated and proven equivalent following Alberta Environment’s
Interpretation of the Reference Method for the Canada-Wide Standard for Petroleum Hydrocarbons in Soil, Validation of Performance-Based Alternative Methods September 2003.
Documentation is available upon request. Modifications from Reference Method for the Canada-wide Standard for Petroleum Hydrocarbons in Soil-Tier 1 Method: F2/F3/F4 data
reported using validated cold solvent extraction instead of Soxhlet extraction.
(4) Index of Additive Cancer Risk,     (C) denotes coarse,    (F) denotes fine.

Encryption Key

Please direct all questions regarding this Certificate of Analysis to your Project Manager.
Carmen McKay, Key Account Specialist
Email: Carmen.MCKAY@bvlabs.com
Phone# (403)219-3683
====================================================================
This report has been generated and distributed using a secure automated process.
BV Labs has procedures in place to guard against improper use of the electronic signature and have the required "signatories", as per ISO/IEC 17025, signing the reports. For
Service Group specific validation please refer to the Validation Signature Page.

                                                                                        Total Cover Pages : 2
                                                                                            Page 2 of 24
                                           Bureau Veritas Laboratories Calgary: 2021 - 41st Avenue N.E. T2E 6P2   Telephone (403) 291-3077   Fax (403) 291-9468
You can also read