GENERAL INFORMATION

GENERAL INFORMATION                                                                STRUCTURAL PRECONDITIONS                            To prevent the parts from becoming dirty,
                                                                                                                                       gloves must be worn during assembly. If the
This assembly manual addresses all metal                                           Metal ceilings may usually be installed as          ceiling products are delivered wrapped in a
ceilings manufactured by durlum. The dif-                                          soon as the building is swept clean and at          protective film, they must be protected from
ferent sections describe the corresponding                                         the latest after all wet work in the interior       exposure to UV radiation [sunlight], the film
products.                                                                          has been completed and the building has             must likewise have been removed from the
                                                                                   been closed.                                        goods no later than 4 weeks after delivery.
durlum is a leading German manufacturer                                                                                                The storage temperature must not exceed
of metal ceilings and cladding elements,                                           Prior to starting assembly, the suspension          30° C, since otherwise the adhesive on the
mainly made of aluminium.                                                          points must be checked for their usabil-            panel may become hardened, and the pro-
                                                                                   ity, and load introduction into the building        tective film can no longer be removed.
                                                                                   must be guaranteed.

                                                                                   When using wall mounting points, such as            STORAGE
                                                                                   brackets or wall anchors, the load-carrying
                                                                                   capacity of the wall in question must be            durlum metal ceilings are usually delivered
                   CERTIFICATE                                                     checked.                                            on pallets. It is advisable to leave the metal
                                    The Certification Body
                                                                                                                                       panels on the pallets as long as possible. If
                                                                                   If ceiling elements rest on brackets, pos-          the pallets have to be opened, the durlum
                            of TÜV SÜD Management Service GmbH
                                             certifies that

                                                                                   sible wall movements must be taken into             metal panel should always be positioned
                                                                                   account.                                            on the long side, it can then be placed
                                       durlum GmbH
                                        An der Wiese 5
                                       79650 Schopfheim
                                                                                                                                       carefully against the wall, do not store flat.
                                           Germany
                                                                                   Only dowels for which a general building
                                                                                   supervisory approval is available may be            Storage must be carried out such that
                                      has established and applies
                     an Energy, Quality and Environmental Management System
                                for the following scope of application:

                       Planning, development, manufacturing and sales of
                                                                                   used, and their minimum extraction force            damage is excluded. During storage,
                          metal ceilings, functional ceilings, luminaries,
                                  lighting and daylight systems.                   must be greater than 100 kg. The dowels             durlum ceiling panels have to be protect-
                           Performance of audits (Report No. 70014435)
                          has furnished proof that the requirements under:
                                                                                   must be mounted as specified by the rele-           ed from all weather influences. They have
                                      ISO 50001:2011                               vant dowel manufacturer. We recommend               to be stored at a constant temperature of
                                       ISO 9001:2015
                                      ISO 14001:2015                               performing regular tensile stress tests, to         between at least 10°C and at most 40°C.
                                             are fulfilled.                        verify that dowels have been set correctly.
                      The certificate is valid from 2017-04-06 until 2020-04-05.
                      Certificate Registration No.: 12 340/100/104 25601 TMS.                                                          The assembly of the ceiling panels must
                                                                                   durlum metal ceilings are dimensioned               not start until all dust-producing work has
                                      Product Compliance Management
                                            Munich, 2017-04-06
                                                                                   such that they carry their own weight of            been completed [swept clean].
                                                                                   the system construction plus a surface              durlum products are certified according to
                                                                                   load amounting to 40 N/m². Higher loads             ISO 9001 for development, production, sales
                                                                                   must be taken into account or suspended             and also for service. Nonetheless, it is recom-
                                                                                   separately in the construction, and the             mended as a matter of principle to inspect
All durlum systems are systems of modu-                                            measures must be adapted to the situa-              the delivered metal ceilings immediately and
lar design. This applies not only to the                                           tion at hand. Usually, built-in components          to report complaints immediately [as a rule
substructure but also to the ceiling parts                                         and loads must be suspended separately.             immediately after delivery or within 3 days].
that are suspended, locked into place or
placed on the substructure.                                                        For ceiling systems that do not allow any
                                                                                   tolerance compensation within a module,             STANDARDS AND REGULATIONS
durlum metal ceilings comply with the                                              suitable material expansions must be tak-
standard EN 13964:2007 and are CE-cer-                                             en into account.                                    The relevant regulations applicable at the
tified.                                                                                                                                installation site must be determined by the
                                                                                   Building expansion joints and tolerances            assembly company in question. The ceilings
                                                                                   customary in building construction must             marketed by durlum comply with EN 13964.
GUIDELINES                                                                         be taken into account accordingly.                  This standard also regulates the classifica-
                                                                                                                                       tion of fire protection.
These installation instructions have been                                          durlum metal ceilings are, as a matter of
structured in accordance with the require-                                         principle, to be assembled by professional
ment of EN 13964:2007. They describe a                                             dry construction companies who are ca-              APPLICATION
proper installation.                                                               pable of assessing the overall conditions
                                                                                   of the building, the metal ceiling and clad-        The application of durlum metal ceilings is
The description does not exempt the user                                           ding, and can take the necessary precau-            restricted, unless agreed upon otherwise,
from examining the structural conditions,                                          tions for correct, safe static mounting.            to interiors, so that, pursuant to EN 13964,
implementing the building code regula-                                                                                                 class of use 1, corrosion protection class A,
tions and observing the information given                                          If parts from different manufacturers are           has been defined here as standard.
in the building permit prior to starting as-                                       used to assemble the ceiling, the relevant
sembly. They have priority, but could not                                          mounting company must provide the cer-
be included here.                                                                  tificates required by EN 13964:2007 and             QUALITY STANDARD
                                                                                   must obtain suitable certificates of con-
It is advisable always to draw up assembly                                         formity itself.                                     For material properties, dimensions, toler-
diagrams/drawings, to establish the loca-                                                                                              ances, colour deviations, the TAIM Direc-
tion where assembly is to begin and to es-                                         Liability for proper selection of the products      tives [Technischer Arbeitskreis Industrieller
tablish the required suspension points for                                         and system conformity can only be as-               Metalldeckenhersteller e.V.] (Technical As-
the relevant ceiling system prior to starting                                      sumed for the systems delivered by durlum.          sociation of Industrial Metal Ceiling Manu-
assembly.                                                                                                                              facturers) applies.

© durlum GmbH | durlum.com | Subject to changes of dimensions and design. Errors reserved. All rights reserved. | Issued: 15.07.2020                                               2
OPEN-CELL CEILINGS INSTALLATION MANUAL

MOUNTING SEQUENCE                                                         The position of the primary profiles is
                                                                          defined in the reflected ceiling plan.
1.    Create a ceiling layout plan or use the
      one from the architect.                                       11. If the panels are placed on a perime-
                                                                        ter trim, we recommend our F-bracket
2.    Cross-check the ceiling layout plan                               as bracket or as stepped F-bracket.
      against the on-site situation.                                    The bracket secures the panel and
                                                                        protects it against lifting. The ceiling
3.    Prepare a bill of materials, including a                          panel is cut with electric sheet shears
      suitable work plan and retrieval/order                            [i.e. Treco shears] and adapted to the
      of the materials required.                                        prevailing room dimensions.

4.    Determine the required suspension                             12. Attachments or other loads are to be
      points in accordance with the classes                             mounted separately. For logical rea-
      of use of EN 13964. The correspond-                               sons these parts are integrated during
      ing suspension distances for the dif-                             the mounting process.
      ferent systems can be taken from the
      detailed descriptions of the individual                       13. After completion and pre-acceptance
      ceiling systems.                                                  of the ceiling, the sequence of joints
                                                                        should be re-aligned. Soiled ceiling
5.    Define which generally approved dow-                              panels should be cleaned to give a
      el is suitable. Check the raw ceiling                             perfect result for assembly.
      and the walls.

      Mark the dowel mounting holes and
      drill them.

      Mount the dowels as specified by the
      dowel manufacturer and carry out ex-
      traction tests using the device recom-
      mended by the dowel manufacturer, if
      necessary.

6.    Follow the same procedure when
      mounting the perimeter trim, mounting
      interval approx. 400-625 mm, check
      transmission of force into wall.

7.    Shorten the provided fastening ele-
      ments, such as the M6/M8 threaded
      rod to the intended length or order the
      correct length and mount it on the raw
      ceiling.

8.    As a rule, arrangement of the panels
      should be from the centre of the room
      to compensate or halve the tolerances
      of the room/panels. The precise ar-
      rangement must always be done on
      the basis of the ceiling layout plan.

9.    As a rule, durlum metal ceilings are
      provided with cross grids [primary pro-
      file].

10. Use the layout plan to determine in
    which direction the cross-bracing pro-
    files are laid, either in parallel to the
    façade [usually] or vertically to the fa-
    çade. The cross bracing profiles should
    be mounted via a wall bracket or via a
    diagonal anchoring to prevent shifting
    in transverse direction.

      The respective primary profiles are
      mounted at a right angle to the sec-
      ondary profiles. To this end, the sys-
      tem-specific connecting elements are
      used, see system descriptions.

© durlum GmbH | durlum.com | Subject to changes of dimensions and design. Errors reserved. All rights reserved. | Issued: 15.07.2020   3
OPEN-CELL CEILINGS INSTALLATION MANUAL

                                                                                                                                          Panel with recessed U 94 for
                                                                                                                                          edge mounting

                 Threaded rod M6 max.
                 1500 mm

       U 1041    U 1040 max. 1200 mm
                                                                     Panel in waiting position

                                           U 94

                                                                                                 Panel folded down

  U 94                                                                       U 1040                                                    V 94

  U 1041                                                                     C 94                                                      Dismounting tool

© durlum GmbH | durlum.com | Subject to changes of dimensions and design. Errors reserved. All rights reserved. | Issued: 15.07.2020                                     4
OPEN-CELL CEILINGS INSTALLATION MANUAL

                                                                                                           ≤ 1200 mm

                                                                                                                                Screw + nut M6

                                                             Threaded rod M6                                           Spring panel hanger C94

                                                             L-shaped primary carrier U1040                                           Carrier U 94
     min. 138 mm

                                                                                                                                                                               30 mm
                   133 mm

                                                                                                                                                                                       96 mm
                                                                                                                                             37 mm

                                                                                                                                                                               66 mm
                                                                                                                                     56 mm

                                                                                                                                                                       42 mm
                                                          Secondary blades
                                                                                                                                                               15 mm

                                                           Secondary blade pitch                                                                     ½ Pitch
                                                                                                                       Main blades
                                                                                    STARLAM panel length

INSTALLATION OF THE COMPONENTS U 1040 UND U 94

1                                                                                                                  2

                                                         Lock U 1041 on both
                                                         sides with M6 nuts

       Connect U 1041
       at the joint with M6
       bolts and nuts

                                                                                                                        Connect U 94
                                                                                                                        to installed U 1040

3

    Connect V 94 to installed U 1040

© durlum GmbH | durlum.com | Subject to changes of dimensions and design. Errors reserved. All rights reserved. | Issued: 15.07.2020                                                           5
OPEN-CELL CEILINGS INSTALLATION MANUAL

INSTALLATION OF THE PANELS

                                                                                                                                       Place spring        Press panel on the
                                                                   Mount spring C 94 to the baffle                                     hooks crosswise     narrow side upwards
                                                                                                                                       and slide them      to the final position,
                                                                                                                                       through the long    allowing the punched
                                                                                                                                       hole of the U 94    slots of the baffle
                                                                                                                                       upwards to bring    to engage with the
                                                                                                                                       the panel into a    punched slots of the
                                                                                                                                       waiting position.   U 94.

DISMOUNTING THE PANELS
                                                                                                                        1

                                                                                                                        2

                                                                                                                        3

    For disassembly, always use the dismounting tool and pull the panel
    always downwards at the retaining spring C 94.

© durlum GmbH | durlum.com | Subject to changes of dimensions and design. Errors reserved. All rights reserved. | Issued: 15.07.2020                                            6
OPEN-CELL CEILINGS INSTALLATION MANUAL

ABBREVIATIONS                                                       2.    Outline the upper edge of the perimeter trim.                Installation of the secondary profile [U 94]:
                                                                    3.    Mark the drill hole.                                         19. Outline the predefined axis grid for the
AP: Distance of primary profiles U 1040                             4.    Drill a hole for the dowel.                                      secondary profiles at the L-shaped pri-
AS: Distance of secondary profiles U 94                             5.    Secure the perimeter trim with a dowel.                          mary carriers.
AH: Distance of the suspension hangers in                           6.    Cleanly mitre cut the edges of the pe-                       20. Cut U 94 carrier to the required length.
    axial direction of the primary profile                                rimeter trim profiles.                                       21. Align U 94 and connect it to the U 1040
                                                                                                                                           primary grid using the M6 screw kit.
                                                                    Installation of the primary profile [U 1040]:                      22. Centre the longitudinal connector V 94
DISTANCE OF THE SUSPENSIONS ETC.                                    7. Outline the axis grid for the primary                               above the joint of the U 94 profile and
                                                                        and secondary profiles.                                            secure it with the M6 screw kit. Required
Distance of the primary profiles AP                                 8. Define the suspension points.                                       longitudinal connections should be ar-
according to EN 13964:                                                  8.1. The suspension hangers of the                                 ranged in an offset manner.
• Class 1: