More efficiency in hotels - with HVAC, lighting and security
←
→
Page content transcription
If your browser does not render page correctly, please read the page content below
The worldwide standard for home and building control More efficiency in hotels – with HVAC, lighting and security Simply comfortable: Higher energy efficiency and more flexibility thanks to Synco HVAC controllers and GAMMA building control Answers for infrastructure.
Saving energy and staying flexible in every season Thanks to intelligent energy saving functions, Synco™ heating, ventilation and air conditioning controllers in connection with GAMMA building control lower the energy consumption in hotels – and thus their operating costs. The individual system components offer ease of use, ensure reliable operation and optimize the room climate in hotel rooms, lobbies, restaurants and spa areas. This provides for optimal comfort and the right ambience in any location. In addition, your investments are protected because Synco HVAC controllers and GAMMA building control components are highly flexible and can easily be adapted to new room configurations, changed occupancy schedules or building extensions. 2
Intelligent technology for energy-efficient hotels Well-prepared for any eventuality focus their attention on the seminar they Highlights Modern hotels need to satisfy a number are attending. Another benefit is the of requirements: Perfect comfort, highest straightforward operation of all systems – ■■ nergy and cost savings E security and straightforward operation at be it in the hotel room by individual guests thanks to automated control minimum cost and maximum energy effi- or centrally for the entire building by the and energy saving functions ciency. With Synco and GAMMA, Siemens facility manager. ■■ ptimal room climate in every O offers the right building technology to area of the hotel easily satisfy these complex individual Green efficiency for your hotel ■■ lexible adaptation to new F requirements – today and tomorrow. Cut your operating costs and attain requirements based on KNX energy class A with state-of-the-art build- ■■ oordinated building tech- C Fluctuating room occupancy, presence ing technology from Siemens: Synco and nology for maximum comfort detection using hotel card switches or GAMMA prevent the waste of energy and energy cost savings conference areas with flexible room con- caused by unnecessary lighting, air con- ■■ reen image thanks to a high G figuration: not a problem. Thanks to the ditioning and heat losses. This allows you level of energy efficiency internationally recognized KNX communi- to reduce energy costs, contribute to cation standard for home and building environmental protection and give the ■■ eliable, expandable products R from a single source control, functions can be extended easily hotel a green image. and flexibly without having to run new wires. In addition, electrical, heating, Reliable, future-proof products ventilation, air conditioning and media from a single source devices from different vendors can com- As a single-source provider of building municate with each other, thus allowing technology, Siemens offers you a com- new functions to be added at a later stage. prehensive solution – from the production of heating and cooling energy to the Intelligent comfort and distribution of thermal and electrical straightforward operation energy – tailored to the specific needs of Whether it is a pleasant room temperature, hotels. Thanks to its modular concept and good air quality or atmospheric lighting, open communication, this solution can Synco and GAMMA make it easy to create be modified or extended at any time, the right ambience at the right time. This ensuring that you will be on the safe side allows guests to relax in comfort or to in the future as well. 3
Lower energy costs and optimal comfort Up to 20 percent energy savings through time- and presence-dependent temperature control – Daily, weekly and seasonal programs based on occupancy schedules – Occupancy-dependent temperature control with presence detection via presence detectors, hotel card switches or connectivity to the reservation system 20 to 70 percent energy savings through demand-controlled ventilation – The ideal amount of fresh air at the right temperature – at any time – Optimal air quality and humidity – Ideal working conditions Up to 30 percent energy savings through individual room control and automatic data exchange with the heating/cooling plant – Temperature can be individually adjusted for every room – Automatic data exchange eliminates unnecessary heating or cooling – Window contacts, hotel card switches and presence detectors prevent the waste of energy
Up to 45 percent energy savings through time-, presence- and daylight-dependent lighting control – Automatic control of lighting – Optimal lighting conditions at all times – Only as much artificial light as needed thanks to constant light control – Extensive lighting control through straightforward integration of DALI (Digital Addressable Lighting Interface) Up to 30 percent energy savings through time- and daylight-dependent shading control – Automatic control of shading – Scene control, e.g. for video projector presentations Straightforward operation and monitoring of energy efficiency – Energy indicator reports unfavorable settings via e-mail or HomeControl app – Easy internet-based operation by facility manager or service personnel from any location
The right user interface for every type Intelligent control of application: From simple pushbuttons Typically, basic lighting requires only a to multifunctional touch panels and subset of the existing lamps. Rotation central display of all essential building switching ensures that all lamps are utilized information. equally by alternating between all lamps for basic lighting. This distributes usage across all lamps, prevents uneven wear and eliminates constant lamp replacements. Since the operating hours of each lamp are recorded, the maintenance staff knows exactly when a specific lamp needs to be replaced. Siemens brings safety and security Automatic safety functions Safety and security thanks to Highlights If there is a fire alarm, electrical consumers remote monitoring are immediately shut down and escape Web-based visualization on a PC or con- ■■ igher security level with no H route lighting is switched on. In addition, trol panel displays all important building need for extra personnel thanks to automatic security air dampers are shut and fans are turned information, including alarm and status functions off. If smoke occurs, air dampers are messages such as lamp failures or lamp opened and fans are turned on to ensure brightness. The energy indicator monitors ■■ L ower risk of accidents thanks that escape routes are free of smoke defined settings for heating, ventilation to efficient corridor, pathway and escape route lighting and evacuation is easier. and air conditioning, shows limit viola- tions and reports them periodically via ■■ aster intervention through F Safe lighting e-mail or app. In addition, water detectors notification via e-mail or text messaging (SMS) Presence-dependent corridor lighting sense burst pipes and flooding early on. ensures the right light level at the right time. Outdoor and pathway lighting can This ensures quick response, prevents or be switched depending on brightness, reduces damage and guarantees reliable motion or time. Should a power failure and efficient operation. There is no need occur, safety is guaranteed at any time to install special alarm devices: When the thanks to emergency lighting. system is in monitoring mode, an alarm message is triggered every time a lamp is switched on or a window or an exterior door is opened. These messages can then be forwarded via text messaging (SMS) or e-mail. 6
Everything for efficiency, flexibility, safety and security General The different areas Energy efficiency, economy and comfort Hotel rooms Time- and presence-dependent temperature control Presence detection using hotel card switches Individual temperature control for every room Presence-dependent and/or reservation system-controlled Demand-controlled heating or cooling for every room temperature control Individual room control Demand-controlled ventilation Automatic deactivation of unneeded consumers such as TVs and lights Economy mode when window is open Intuitive operating controls Energy indicator and HomeControl app Lobby/reception Automatic deactivation of unneeded consumers Adjustment of room temperature upon check-in/check-out Lighting control: – Control via time programs Monitoring of room occupancy and settings – Presence-dependent control Demand-controlled ventilation – Constant light control Automatic lighting control – Light color control and light effects with DALI Receipt of alarm messages from guests and alerts Rotation switching and maintenance based on operating hours Straightforward visualization of all relevant areas on a PC, Straightforward operation of all devices by guest or staff tablet or smart phone Safety and security Restaurant and spa areas Automatic response in the event of fire alarm Individual room control (control of fire protection dampers) Demand-controlled ventilation Comprehensive visualization of building information, e.g. location of hazard Air quality and humidity control Secure building operating state during the night Automatic lighting control Display of operating states and malfunctions Water detectors Monitoring without special alarm system Consumption data acquisition Alarming via text messaging (SMS) or e-mail Parking garage Presence-dependent corridor lighting Time- and presence-dependent lighting control Brightness-, motion- and/or time-dependent outdoor and pathway lighting Rotation switching for more even lamp wear Emergency lighting in case of a power failure Maintenance based on operating hours 7
Siemens Switzerland Ltd Infrastructure & Cities Sector Building Technologies Division International Headquarters Gubelstrasse 22 6301 Zug Switzerland Tel +41 41 724 24 24 Siemens Building Technologies Infrastructure & Cities Sector Brunel House Sir William Siemens Square, Frimley Camberley Surrey, GU16 8QD United Kingdom Tel +44 1276 696000 Siemens Ltd Infrastructure & Cities Sector Building Technologies Division 22/F, AIA Kowloon Tower, Landmark East 100 How Ming Street Kwun Tong, Hong Kong Tel +852 2870 7888 The information in this document contains general descriptions of technical options available, which do not always have to be present in individual cases. The required features should therefore be specified in each individual case at the time of closing the contract. © Siemens Switzerland Ltd, 2013 • BT_0030_EN Answers for infrastructure. Our world is undergoing changes that force us to think “We are the trusted technology partner for in new ways: demographic change, urbanization, global energy-efficient, safe and secure buildings and warming and resource shortages. Maximum efficiency infrastructure.” has top priority – and not only where energy is concerned. In addition, we need to increase comfort for the well-being of users. Also, our need for safety and security is constantly growing. For our customers, success is defined by how well they manage these challenges. Siemens has the answers. www.siemens.com/synco www.siemens.com/gamma
You can also read