Position Paper
Light Commercial Refrigeration
  Refrigerants Outlook for United States and Canada
                       2020

                  www.embraco.com
Light Commercial Refrigeration - Position Paper 2020 - Refrigeration Club
Introduction   With the Kigali Amendment to                    GWP of the refrigerants in use
               Montreal     Protocol,        the    global     without compromising the indirect
               community made another important                CO2 emissions during the lifetime
               step     towards        preserving       our    of the equipment. Canada is headed
               planet for future generations by                in the same direction with recently
               reducing CO2 emissions due to                   published new HFC rules imposing
               human activities. The global phase-             bans on high-GWP refrigerants for
               down of HFCs in the refrigeration               specific applications. In Europe
               sector represents an important                  F-gas regulations have imposed
               contribution to international climate           progressive bans on certain high-
               change     mitigation         efforts.   For    GWP     refrigerants   for   common
               many years, Embraco has been                    refrigeration    applications,      as
               actively investing in this direction            well as a “quota system” limiting
               by     developing       and     promoting       the available quantities of HFC
               hermetic compressors for use with               refrigerants on the market. In
               low-atmospheric impact refrigerants             addition to the natural refrigerants
               on all continents. In addition to               mentioned        before,       several
               isobutane (R600a) in household                  alternative synthetic refrigerants
               appliances, significant progress has            have   been     developed     by   the
               also been made integrating propane              chemical industry and more are
               (R290) into light commercial plug-              coming. Embraco has performed
               in systems as well in the use of                extensive tests to assess the
               carbon dioxide in the supermarket               capacity of these alternatives to
               sector. In the US, even though EPA              replace    high-GWP        refrigerants
               rules on the subject have been                  presently in use. The most difficulty
               suspended by the US courts for                  was found in trying to replace
               the time being, California and two              R404A. This paper will summarize
               other states have recently adopted              current testing for R404A and
               HFC     regulations       limiting       high   R134a replacements, with a focus
               global warming potential (GWP)                  reliability and performances as well
               substances in air conditioning and              as the evolution of related safety
               commercial refrigeration. All these             legislation.
               developments point in a similar
               direction: the need to lower the

                                   2
Embraco Policy   ●   Embraco will encourage the      ●   Embraco will continue to
Statement            use of low GWP refrigerants         develop products for both
                     to support global effort to         natural and synthetic
                     mitigate climate change.            low-GWP refrigerants that
                                                         exceed present and future
                 ●   Embraco will continue to
                                                         energy efficiency standards
                     provide solutions to improve
                                                         in order to assure the
                     the energy efficiency of
                                                         competitiveness of our
                     refrigeration equipment with
                                                         products and expectations
                     low-GWP refrigerants.
                                                         of our end users.
                 ●   Embraco will support the
                                                     ●   Embraco will continue to work
                     proactive use of natural
                                                         with international legislative
                     refrigerants without
                                                         bodies on the safe use of
                     compromising appliance safety
                                                         low-GWP refrigerant options.
                     or technician training.

                                  3
Canada HFC Rules

On October 18, 2017, the Canadian govenment announced amendments to its existing Ozone-depleting Substances
and Halocarbon Alternatives Regulations. The changes include a phase-down in bulk HFCs as well as prohibitions
on HFCs in certain types of equipment as shown in Table 1.

Table 1 Canada HFC Rules and Effective Dates

                                                                  GWP LIMIT                   DATE

       REFRIGERATION – CENTRALIZED SYSTEMS
                                                                     2200                     2020
                  (MT/LT RACKS)

         REFRIGERATION – CONDENSING UNITS                            2200                     2020

           REFRIGERATION – LT STAND-ALONE                            1500                     2020

          REFRIGERATION – MT STAND-ALONE                             1400                     2020

                MOBILE REFRIGERATION                                 2200                     2025

                        CHILLERS                                      750                     2025

                                                      4
California HFC Rules

California is driving aggressive regulation at a state level by adopting vacated EPA Rules 20 and 21 and delisting
high-GWP refrigerants with a bill approved in August 2018 (Table 2). Several other states in the US Climate Alliance
(24 states representing 50% of the US population and 57% of the country’s GDP) have either already adopted
(Washington and Vermont) or are expected to adopt similar legislation very soon (New York, Maryland, Connecticut).

Table 2 California Delisted Refrigerants

  DELISTED REFRIGERANT                        APPLICATION                            EFFECTIVE DATE

                                           Supermarket Systems                       January 1, 2019

                                      Remote Condensing Units                        January 1, 2019
         R404A*
       UNACCEPTABLE
                                 Stand-alone Retail Units Low Temp                   January 1, 2020

                                  Refrigerated Food Processing and
                                                                                     January 1, 2021
                                        Dispensing Equipment

                                      Stand-alone Retail Units
                                                                                     January 1, 2019
                                    Medium Temp
EU F-Gas Regulation

The European Union was          From January 1, 2020
the pioneer in F-gas phase-    - Hermetically sealed systems that
down with the introduction     contain HFCs with GWP of 2500
of regulations (517/2014)      or more (e.g. R404A, R507A) will
                               be banned in refrigerators and
limiting the use of
                               freezers used for storage, display or
refrigerants with high GWP
                               distribution of products in retail and
values. Current EU deadlines   food service (commercial use).
for refrigerant use in new
equipment include:             From January 1, 2022
                               - Hermetically sealed systems
                               that contains HFCs with GWP of
                               150 or more (e.g. R134a R407F,
                               R407C, R410A) will be banned in
                               refrigerators and freezers used for
                               storage, display or distribution of
                               products in retail and food service
                               (commercial use).

                               From January 1, 2020
                               - Stationary refrigeration equipment
                               that contains, or that relies upon for
                               its functioning, HFCs with GWP of
                               2500 or more (except equipment
                               intended for application design
                               to cool products to temperatures
                               below -50°C) will be banned.

                                                 6
Alternative Refrigerants
for Commercial Refrigeration
Embraco is working on products           that should allow the industry to    have to wait until current safety
for    the     light   commercial        convert their products portfolio     standards and codes (under
refrigeration segment that comply        into low-GWP alternatives in the     development) have been updated.
with present and future F-gas            future. For the time being, only     Every appliance producer has a
regulations, focusing mainly on          hydrocarbons can be considered       choice to make: go natural within
products that meet final target          a future-proof solution in self-     the present charge limitations or
limit (
Final Target Limit Hydrocarbons
PROPANE (R290)                                                                     OTHER HYDROCARBONS:
                                                                                   ISOBUTANE (R600a)
Embraco offers a full product line    At a global level, the new IEC               R600a - isobutane - represents
of HC compressors that conform        standard (IEC60335-2-89), published          a   valid      alternative       solution
to the final limits set by current    in June 2019 allows up to 500 g              for small appliances. It offers
F-gas regulations. R290 is already    (17.7 oz) of propane charge and              benefits in terms of efficiency
widely used in several commercial     1.2 kg (2.64 lb) of A2L class                but has significant limitations in
applications and most of existing     refrigerants        for    self-contained    terms of cooling capacity. Due to
light   commercial    applications    commercial          applications      such   its low specific cooling capacity,
can be converted to use those         as   ice    makers,        with   specific   it requires bigger compressor
refrigerants. In the case of larger   additional mitigation measures               displacement compared to other
applications, due to the general      to maintain the same risk level as           refrigerants     and     consequently,
charge limit of 5.3 oz., multi-       per the 150 g limit.                         a larger and heavier compressor
circuit configuration is a feasible   In   most      of    the     world,   this   frame.      Isobutane’s      properties
option and already applied in         new standard can already be                  can also limit the evaporating
some systems. An important step       applied (e.g., Brazil) but in the            temperature range.
will be modifying safety standards    US and Europe it still must                  Embraco’s      catalog      features   a
to allow wider use of A3 class        be firstly adopted by region/                full range of products utilizing
refrigerants. Present EPA SNAP        country     as      part    of    existing   isobutane      for    LBP    and    HBP
listings allow for 5.3 oz (150 g)     safety     standards        and    codes.    applications,        including     small
of R290 or R600a charge for           Though activity is in progress, the          chest freezers, bottle coolers and
hermetically sealed applications      conclusion is still unclear.                 wine coolers.
in light commercial refrigeration.

                                                            8
Next Generation HFCs

R404A ALTERNATIVES
In the long term, the industry                up to 22R. Tables 4 and 5 list some                 One important step toward allowing
under the AHRI’s AREP (Alternative            long-term alternatives to R404A                     wider use of A2L class refrigerants
Refrigerant Evaluation Program)               that Embraco is testing for the light               is the safety standards updates (the
has tested a series of new mixtures           commercial segment. It is important                 same applies to A3 safety class
with GWP of less than 150. All these          for the refrigeration industry to avoid             mentioned before).
candidates are slightly flammable             refrigerant proliferation. Hopefully
and belong to the A2/A2L                      market forces will help speed the
classification with temperature glide         adoption of a global standard.

Table 4 Alternative Blends Physical Data

                                         R 404A                       R455A                        R454C
           TYPE                        HFC blend                   HFC blend                    HFC blend
      SAFETY CLASS                          A1                           A2L                         A2L
 BOILING TEMP @ 1atm                      -53°F                        -51°F                       -49°F
     CRITICAL TEMP                       162°F                        181°F                        180°F
 BUBBLE-DEW @14.5 PSIA                    1.4R                        22.3R                        14.7R

Table 5 Embraco Evaluation Summary

                                         R 404A                       R455A                        R454C
            GWP                           3920                           146                        146
         CAPACITY                          Ref                         Same                        Lower
       EFFICIENCY                          Ref                        Better                       Better
        RELIABILITY                        Ref                           NA                          NA
        LUBRICANT                          POE                           POE                        POE
       MOTOR TEMP                          Ref                        Higher                       Higher
    DISCHARGE TEMP                         Ref                        Higher                       Higher

                      (*) due to safety requirements for electrical components, UD under development, NA not available

                                                                     9
Next Generation HFCs

R134a ALTERNATIVES
R1234yf is a valid alternative for         commercial systems because of
R134a appliances, so Embraco               its low specific cooling capacity.
offers some compressor models              Its use would require a completely
with this refrigerant in its catalog.      new product line that, at this
R1234ze is not considered a valid          stage, does not seem to be a
alternative to R134a for light             solution for this market segment.

Table 6 Alternative Blends Physical Data

                                                 R 134a                           R1234yf                         R1234ze (E)
                TYPE                               HFC                               HFC                                HFC
          SAFETY CLASS                              A1                                A2L                               A2L
     BOILING TEMP @ 1atm                          -15°F                             -22°F                            -2.15°F
         CRITICAL TEMP                           214°F                              203°F                              230°F
     BUBBLE-DEW @14.5 PSIA                          0R                                0R                                 0R

Table 7 Embraco Evaluation Summary

                                                 R 134a                           R1234yf                         R1234ze (E)
                GWP                               1430                             Below 1                           Below 1
             CAPACITY                              Ref                         Slightly lower                     Much Lower
            EFFICIENCY                             Ref                              Lower                              Lower
           RELIABILITY                             Ref                              Same                                 NA
            LUBRICANT                              POE                               POE                                 NA
           MOTOR TEMP                              Ref                              Same                                 NA
        DISCHARGE TEMP                             Ref                              Same                                 NA
                                             (*) due to safety requirements for electrical components, UD under development, NA not available

                                                               10
HFC Transitional Solutions

R404A REPLACEMENT
To ease the transition to                  They are all in safety class A1
refrigerants that comply with               (non-toxic, non-flammable) and
target final GWP limits, the               are    all    characterized   by
chemical industry offers several           considerably higher temperature
alternatives to existing high-GWP          glide than R404A. Tables 8 and 9
HFC refrigerant blends. The most           outline Embraco’s evaluation of
notable intermediate refrigerant           the main physical proprieties of
candidates are HFC blends like             these blends.
R448A, R449A and R452A.

Table 8 Alternative Blends Physical Data

                                    R 404A                R448A                R449A       R452A
           TYPE                    HFC blend             HFC blend            HFC blend   HFC blend
      SAFETY CLASS                     A1                      A1                A1          A1
 BOILING TEMP @ 1atm                 -53°F                 -49°F                -51°F       -53°F
     CRITICAL TEMP                   162°F                 183°F               180 °F      167°F
 BUBBLE-DEW @14.5 PSIA                1.4R                 11.3R                11R         6.8R

Table 9 Embraco Evaluation Summary

                                    R 404A                R448A                R449A       R452A
            GWP                      3920                  1386                 1397        2140
         CAPACITY                     Ref                 Better               Better       Same
       EFFICIENCY                     Ref                 Better               Better       Same
        RELIABILITY                   Ref                  Lower               Lower        Same
        LUBRICANT                     POE                      POE              POE         POE
       MOTOR TEMP                     Ref                 Higher               Higher       Same
    DISCHARGE TEMP                    Ref                 Higher               Higher       Same

                                                          11
HFC Transitional Solutions

Both R448A and R449A were              If an application is using an Embraco   R452A presented the same or
approved as an alternative             R404A compressor outside of             lower thermal profile when
refrigerant to R404A for the NE/       this above mentioned restricted         compared with R404A. R452A
NT/NJ compressor series (ECN           envelope, please contact Technical      can be considered as an
R449A 2018 and ECN R448A               Support for further instructions on     alternative for the Embraco
2019), but with a more restricted      how to adjust the thermal level of      R404A product line (ECN
operating envelope than R404A          the compressor eg.by reducing           R452A 2016) with same
due to the higher internal             return gas temperature.                 operating envelope of R404A,
thermal level of the compressor.                                               but because of EPA SNAP
The restricted envelope for                                                    listings, its use in the US is
R448A/R449A is presented in                                                    limited to remote systems and
Figure 1.                                                                      refrigerated transport.

Tc

150
                                                                                  Operation Condition
140
                                                                                  Transient Condition
130
                                                                               Tc Condensing Temperature °F
120

                                                                               Te Evaporating Temperature °F
110

100

 90

 80

                                                                      Te
      0       10        20       30        40        50          60

      Fig.1 Restricted R448A/R449A Envelope (max. return 68°F)

In addition, customers always          and relative system design              during the transition period just
have the option of converting          adjustment.                             by changing compressor models
systems from R404A to R134a            In addition, customers always           and relative system design
during the transition period just      have the option of converting           adjustment.
by changing compressor models          systems from R404A to R134a

                                                          12
HFC Transitional Solutions

R134a REPLACEMENT
Both proposed alternative blends        GWP replacement refrigerant for
mentioned below (R450A and              R134a systems (see ECN R513A
R513A) can be considered at this        R450A 2017 and ECN CR/2966/
stage as an acceptable lower            en–18/10).

Table 10 Alternative Blends Physical Data

                                             R134a                 R450A       R513A
               TYPE                           HFC                 HFC blend   HFC blend
          SAFETY CLASS                         A1                    A1          A1
     BOILING TEMP @ 1atm                      -15°F                 -11°F      -20°F
          CRITICAL TEMP                      214°F                 223°F       208°F
     BUBBLE-DEW @14.5 PSIA                     0R                   0,9R        1.4R

Table 11 Embraco Evaluation Summary

                                             R134a                 R450A       R513A
                GWP                           1430                  547         573
             CAPACITY                          Ref                  Lower       Same
            EFFICIENCY                         Ref                  Same        Same
            RELIABILITY                        Ref                  Same        Same
            LUBRICANT                         POE                   POE         POE
           MOTOR TEMP                          Ref                  Same        Same
        DISCHARGE TEMP                         Ref                  Same        Same

                                                      13
Warning   Warning Statement About Use
          of Flammable Refrigerants (A2L,
          A3) with Embraco Compressors,
          approved for A1 Safety Class
          Refrigerants (R134a, R404A, etc.)
          Embraco is currently producing
          hermetic compressors for use
          with A3 and A2L refrigerants to
          replace high-GWP HFCs. However,
          it is important to note that:

          1.                                      4.
          Embraco compressors designed            Embraco offers a full portfolio of
          and approved for non-flammable          compressor models for R290, the
          refrigerants (A1 class), cannot be      refrigerant considered the best
          used with any type of flammable         option for both systems with a 5.3
          refrigerants, including both A3         oz (150g) charge limit as well as
          and A2L class refrigerants.             those where new charge limits are
                                                  already in force.
          2.
          Until new charge limits are adopted     5.
          under    the    relevant   standards,   Embraco declines any responsibility
          present regulations allow the use       for compressors used without
          of up to 5.3 oz (150 g) of A3 safety    approved refrigerants, and warns
          class flammable refrigerant per         that potential reliability issues,
          refrigeration circuit.                  such as motor overheating and
                                                  electrical component malfunction,
          3
                                                  could occur with the use of
          Given the above-mentioned charge
                                                  unauthorized refrigerants.
          limitations and considering that
          all flammable refrigerants require
          the same design, manufacturing,
          and maintenance precautions, we
          strongly recommend the use of an
          HC solutions wherever technically
          possible.

                            14
Performance    It is important to consider that      system operating conditions; a
  Evaluation   refrigerants    with    significant   mid-point approach should be
               glide   have    to     be   treated   used. How to define mid-point
               differently than in the past. A       temperature is illustrated Figure
               dew point pressure approach           2 below.
               cannot be used to define actual

                  Fig.2 Mid-point Temperature Chart and Formulas

                               15
Conclusions   Hydrocarbons (isobutane-R600a         R513A and R450A are approved
                                     and propane-R290) represent           as alternatives to R134a for use
                                     the best long-term solution for       during the transition period in
                                     both low and medium pressure          specific Embraco R134a series
                                     light commercial self-contained       (see ECN R513A R450A 2017
                                     applications. Expected safety         and ECN CR/2966/en/18/10).
                                     legislation changes will remove       R1234yf is also an acceptable
                                     some of the existing roadblocks       alternative for R134a also for
                                     related to charge limits for          the long term, but due to its
                                     flammable refrigerants.               flammability, can be used only
                                     As for the transition period, R448A   with specifically designed models.
                                     and R449A mixtures can be used
                                     on specific Embraco R404A
                                     series with restricted envelope
                                     (see ECN R448A 2019 and ECN
                                     R449A 2018). R452A can also be
                                     considered as an alternative (see
                                     ECN R452A 2016) but only for
                                     transport and remote applications
                                     in the US.

                                          CURRENT                TEMPORARY                   FINAL
                                        REFRIGERANT               SOLUTION                 SOLUTION

                                            R404A                  R452A**                   R290*
■ Embraco Approved Refrigerant
                                             R507                   R407C                    R455A
■ Under Approval Process
                                                                  R448A***                   R454C
■ Not Approved
                                                                  R449A***                    R744
                                                                    R134a*                    R744
* different displacement

**only remote and transport
***with restricted envelope
                                            R134a                   R134a                   R1234yf
                                                                    R513A                    R600a*
                                                                    R450A                    R290*
                                                                                              R744

                                                     16
General Trends

   Light Commercial
       Segment from
Embraco’s Prospective

                                       LIGHT COMMERCIAL REFRIGERATION
                                   WATT                    150 - 5000
                               REGION/YEAR       TODAY       2022       2025

                                 AMERICA
                                  EUROPE

                HC                JAPAN
                                  CHINA
                             REST OF THE WORLD

                                 AMERICA
                                  EUROPE
          HIGH GWP                JAPAN
            HFC’s                 CHINA
                             REST OF THE WORLD

                                 AMERICA
                                  EUROPE
           LOW GWP                JAPAN
             HFC’s                CHINA
                             REST OF THE WORLD

                                 AMERICA
                                  EUROPE

               CO2                JAPAN
                                  CHINA

                             REST OF THE WORLD

        ■ MAIN REFRIGERANT

        ■ REGULAR USE

        ■ NICHE USE

        ■ NO CLEAR