Contents 03 Introduction & Manufacturing 30 Vizulinx 54 Miscellaneous Items Alarm Management Solution 58 Taktis® UL 06 Taktis® Fire Analogue Addressable Control Equipment 32 Sigma CP Conventional Fire Alarm Control Panels Fire Analogue Addressable Control Equipment 08 Taktis® Vision Analogue Addressable Annunciators 34 Sigma CP-A AlarmSense Conventional Fire Alarm ® 60 Taktis® UL/Elite Bridge Functionality 10 Taktis /Syncro Bridge ® 36 Control Panels Sigma For Phased Upgrades Functionality CP System Diagram 61 Taktis® UL For Phased Upgrades 38 Sigma XT Network Diagram 12 Taktis Virtual Resource ® Management Tool Extinguishant Control Panel 62 Elite RS For Fire Detection 39 Sigma XT Network Diagram Analogue Addressable Fire Control Panel UL/FM Approved 14 Loop Explorer 2 (LE2) Configuration Software 40 Sigma ZXT 64 eMatrix Analogue Addressable Fire Repeater Extinguishant Control Panel 16 Taktis ® 42 Sigma XT+ UL/FM Approved Network Diagram Extinguishant Control Panel 65 eView 18 Ockular ® Multi-Area Addressable Analogue Addressable Fire Repeater UL/FM Approved Powerful and sophisticated software solution 44 Syncro XT+ 20 Syncro AS Extinguishant Control Panel 66 Sigma A-CP Conventional Control Panel UL Approved Analogue Addressable 1-2 Loop Multi-Area Addressable Control Panels 45 Syncro XT+ 68 Sigma A-XT 22 Syncro AS Network Diagram Extinguishant Control Panel UL/FM Approved Network Diagram 46 Sigma Si 70 Sigma A-Si 24 Syncro Repeaters Extinguishant Status & Ancillary Units Extinguishant Status & Ancillary Units UL/FM Approved Analogue Addressable 48 Fire Cryer Plus Fire Control Panel Repeaters Voice Sounders 72 Marine & Offshore Analogue Addressable 26 Addressable Ident Analogue Addressable 50 Safe-Point 1-2 Loop Control Panel Syncro ASM Emergency Voice Communication (EVC) Fire Control Panel Repeater 52 Power Supplies (PSU) 74 Custom Engineered Solutions 28 Addressable Matrix Intelligent Fire Alarm Mimic Display System For Fire Detection, Alarm and Fire Protection Systems 2
Introduction Protection of people, building and assets from a conventional, analogue addressable fire detection fire is a paramount concern to any organisation. and extinguishant control panels. Founded in Keeping a site safe is not the only priority but with 1985, Kentec is an end-to-end manufacturer, the risk of physical damage and financial loss with everything sold made in the UK. It employs resulting from a fire, there is also the risk approximately 240 members of staff in its to operational performance and reputation, production facility, head office and research and so a reliable and responsive fire system that can development department. respond rapidly to any situation is required. In addition to design and manufacture, Kentec Early warning fire systems and detection provides technical support specified to the local technology can detect a fire, and in the case of standards and customer requirements of over extinguishant detection, it can also automatically 90 countries worldwide. With a commitment to release a fire suppression agent to eliminate fire meeting the needs of individual national markets, within seconds. Stopping a fire within the first Kentec has achieved a global reputation, few moments can reduce or avoid damage to resulting in its life safety systems being installed equipment and assets and subsequent loss of in numerous prestigious sites across the world. operational productivity. Kentec manufactures products approved Kentec Electronics is one of the world’s to EN54, EN12094, UL, FM, NFPA and marine leading life safety solutions manufacturers of classification societies. 3
Manufacturing For Kentec, being at the cutting edge of technology Our manufacturing capabilities and end to end is all about creating a safe environment. This means process enables full control, accountability and developing solutions that provides protection to traceability of our products made in the UK. people and property for when they need it. Our products and manufacturing facility provide the highest quality, assured and audited by world Our R&D teams based in the UK and USA, work leading certification bodies BRE, BSI, UL and FM. together using pioneering equipment and facilities to develop innovative designs, technologies and Over 52,00sq ft accommodates our design to processes. By utilising international expertise, completed end product manufacturing facility, our unique resource along with the creation of an bespoke engineered solutions department, environment to foster collaboration, cohesion and goods-in, stores, QA, and goods-out. cross-fertilisation of knowledge enables a greater solutions-led approach to technology and thinking. Research and Development Mechanical Dispatch Enginnering Electrical Safety, Electrical Final Test & Engineering Inspection Artwork Metal and Digital Fabrication printing Powder Coat finishing 5
Analogue Fire Detection Taktis® is Kentec’s most powerful and Multiple protocols can be supported on each panel sophisticated analogue addressable fire panel. to give installers and end-users maximum choice An intelligent and technically robust fire alarm, in their systems’ design, and the scalable nature it has enhanced integration and networking of the product provides the highest level of future- capabilities to meet the current and future needs proofing and networking possibilities. of all buildings and installations regardless of size. The modular nature of Taktis allows all field Features Initially configured as a fire detection and alarm wiring to be connected to a passive motherboard Up to 512 programmable Input/Output via optional system, the flexibility of Taktis is such that it can enabling addition, re-configuration or replacement plug-in and serially connected expansion cards be re-configured to realise many other control and of all electronic hardware without the need to Two to eight loop or two to 16 loop versions indication applications, with direct integration disconnect any field wiring. This modularity Multiple protocols supported on a single panel into intelligent buildings. also allows each panel to be customised with (in banks of two loops) addressable loop detection circuits, conventional Network up to 128 panels Available in four and eight slot variants, detection circuits, relay cards, additional sounder 500mA loop current Taktis fire control panel ranges from two to outputs or programmable I/O modules as required. Four programmable sounder circuits each rated 16 detection loops. Taktis can network up to 128 at 2.5A panels, making it ideal for the largest sites such as As a truly open protocol panel it offers installers 5.25A or 10.25A power supply options schools, hospitals, multi-site retail/supermarkets, and their customers maximum flexibility in Enclosure options to suit 26Ah or 45Ah battery options critical infrastructure and major commercial and systems’ design, site-customisation and in the Three programmable inputs industrial facilities. third-party devices that they use. Not only does Five programmable relay outputs Taktis provide solutions to the most technically Hard wired fire and fault routing inputs and outputs challenging applications in life safety, it also Over 4000 sub address points per panel delivers added value, market advantage and a Option to ‘invert’ inputs and outputs competitive edge to your business. Configurable via a USB flash drive or alternatively a PC USB serial connection Optional Media Gateway communications card Compatible with Ockular management solution Approved and compliant with EN54-2, EN54-4. EN54-part 13 pending approval 7
Taktis® Vision Analogue Addressable Annunciators Taktis Vision provides a means of allowing full display and optional control of the Taktis fire alarm control panel from a small and unobtrusive local control station. The large, full colour graphical display with touch screen functionality, delivers information on the status of the fire alarm system to single or multiple locations. Taktis Vision repeaters can be configured to offer full display and control to replicate the functionality of the fire control panel or to operate as a simple, display only device for applications where access to control the fire alarm system would be inappropriate. Taktis Vision may be connected to the fire control panels’ fault tolerant RS485 network using standard, fire rated cable offering flexibility in system wiring. Available in several standard formats, Taktis Vision can be mounted directly onto a wall, be recessed using our quick-fix adaptor frame or fully flush mounted. Special enclosure finishes and colours are also available to match existing decor. 8
Analogue Fire Detection Features Robust, full colour, 7" 800 x 480 touch screen graphical display Full indication of all information displayed at the fire control panel Automatic display brightness adjustment Silenceable internal sounder Connections via: • Control panel network • Option to connect to control panel RS485 bus Low current, 24V DC powered Slim compact construction Configurable functionality Configurable languages 9
Taktis®/Syncro Bridge Functionality For Phased Upgrades Kentec has a unique solution for migrating Syncro This bridge capability enables you to plan and panel networks to the latest Taktis technology develop a fire system in line with fire safety protecting the end user’s long-term investment. requirements to the latest product range, without With the Syncro/Taktis bridge functionality causing budgetary difficulties. Importantly this can customers can upgrade their existing networks be done with minimal disruption to the occupants from legacy Syncro fire panels to the new highly- with less cost, stress and risk for all involved. sophisticated and scalable Taktis control panel. Upgrades can be carried out on a panel-by-panel Taktis Vision repeaters can also be installed on a basis, with reduced capital expenditure and Syncro network using the bridge feature, providing minimising essential system downtime. an easy-to-use, full-colour, touch-screen interface that delivers information on the status of the fire The bridge functionality enables customers to alarm system to single or multiple locations. replace a Syncro panel with Taktis within a Syncro network. On a mixed network Taktis panels will function as a Syncro, but once the network is replaced, the full functionality of the feature-rich Taktis will become available. This also enables customers to expand their network in line with Taktis’ scalable capabilities. 10
Analogue Fire Detection Taktis Fire Analogue Addressable Control Panel Syncro Analogue Addressable Control Panel Syncro Analogue Addressable Control Panel Syncro AS Analogue Addressable Control Panel 11
Taktis® Virtual Resource Management Tool for Fire Detection Virtual Resource is an advanced management tool The remote management features offered by for fire detection which provides system designers, Virtual Resource can result in reduced fault integrators and service companies with the ability call outs, reduction of unwanted alarms and to remotely access and comprehensively manage improved overall service to the end user. any system using intelligent analysis of data collected Gain access to data from all your systems, from their systems. End-users and facilities assess performance, check status and make managers can also greatly benefit from the powerful decisions based on facts, not assumptions. feature set that comes with Virtual Resource. VR Access allows your fire system to periodically report its status to the secure servers to enable you to view the latest status report via any web enabled device. Whether you are a service provider, building owner or facilities manager, Taktis VR can help you reduce costs, add value and improve service integrity by employing the latest communication and analytical technologies. 12
Analogue Fire Detection 13
Loop Explorer 2 (LE2) Configuration Software 14
Analogue Fire Detection Loop Explorer 2 (LE2) is a configuration software Powerful standard templates allow rapid which is easy to use even when producing the most configuration of common fire system configurations complex configurations. for applications such as high-rise buildings or alarm verification from hotel rooms. LE2 is highly configurable, enabling customisation of languages, colour schemes and company logos Cause and effect allows the configuration of large, and allowing exposure to single or multiple detector complex networks with ease. Access to LE2 is via a protocols to be set for each user. secure web server, so users with the appropriate credentials have permanent access to the latest Additional logical operators for NOT and TIME version ensuring that the most recent enhancements functions for use in cause and effects and the are always available. LE2 can be customised by the inclusion of ‘groups’ (collections of devices not user so that language or specific terminology can be necessarily in the same zone) increase the power set as defaults for all systems that are configured and flexibility of LE2 to far beyond what was using LE2. Custom changes are stored on our previously achievable. servers, again ensuring that all authorised users have access to the latest customised version. LE2 can also be used to select, (where applicable) the appropriate detection loop protocol. For added convenience, Taktis Virtual Resource It is possible to run different loop protocols subscribers can store LE2 configuration files on our on individual loop cards. secure servers ensuring that the site configuration Features is always backed up and available to users with the Highly configurable software appropriate access rights. Enables customisation of languages, colour schemes and company logos Powerful standard templates allow rapid configuration Cause and effect allows the configuration of large, complex networks with ease. Taktis Virtual Resource subscribers can store LE2 configuration files 15
Taktis Network Diagram Taktis High Network Integrity Diagram Configurable Network High Integrity Configurable Network Cloud Servers GSM Media Gateway IP Dial-Up Taktis Fire 2-8 Loop Analogue Addressable Control Panel 24V DC Taktis Virtual Resource Taktis Vision VR Access – Access data Configurable Fire Alarm from all your systems Repeater Loop 3-Loop 8 (if fitted) Each bank of 2 loops can be different protocols. Loop 2 Each loop is capable of hosting up to: I/O 126 devices (Apollo) or 240 devices (Argus Vega) or Taktis Fire Loop 1 127 devices (Hochiki). 2-8 Loop Analogue Addressable Control Panel 16
Plug in slots IO Cards K772 K791 K792 K793 16 Channel 8 Way 8 Way Conventional 4 Way I/O Board Relay Board Zone Board Sounder Board Taktis Fire 2-8 Loop Analogue Addressable Control Panel The Taktis system is compatible with Apollo, Argus Vega and Hochiki protocols. Panels of any of the above protocols can be used on the same network. Ockular Vizulinx Up to 128 Panels/ Graphical User Interface Fire Alarm Management Repeaters can be for Fire Detection Solution Forthcoming products added to the network. Taktis Serial Repeater Taktis Voice – Loop 3-Loop 16 Fire and Voice control panel (if fitted) Taktis Voice – Each bank of 2 loops Voice evacuation panel can be different protocols. Building management system interface Loop 2 Taktis Fireman’s Telephone Virtual Resource including I/O Each loop is capable of hosting up to: • VR Vault 126 devices (Apollo) or • VR Service module Loop 1 Taktis Fire 240 devices (Argus Vega) or 2-16 Loop Analogue 127 devices (Hochiki). Taktis Emergency Lighting Addressable Control Panel Taktis Smoke Control System Taktis Disabled Refuge 17
Ockular® A powerful and sophisticated software solution No situation requires a more urgent response than a fire event. On a large public site, especially during busy periods, public safety is paramount. A powerful and sophisticated graphical representation of your sites, Ockular® gives building managers complete monitoring and control over fire detection providing a comprehensive fire risk and incident management system. Where time is of the essence, automated control aids site managers to respond quickly and efficiently to a fire event. Ockular plays a crucial role in safeguarding people, vitally important information and property. 18
Analogue Fire Detection Features Supports dual screens, allowing a dedicated screen for the 2D location images and a separate screen for listing active events, and system management Fully configurable on site using administrator login Reports configuration mismatch errors – ensuring that the graphics system is properly maintained and updated whenever there are any panel configuration revisions Powerful event log filtering and reporting Manage the state of the fire system using a combination of graphical images and system controls Programmable macro buttons to perform panel control operations Full map navigation using configurable buttons or map areas Device analogue value reporting Perform device and zone disablements/enablements 19
Syncro AS Analogue Addressable 1-2 Loop Control Panels 20
Analogue Fire Detection Syncro AS is an analogue addressable fire control panel, available in either one or two detection loops. It combines compact and practical styling with the programming power and connectivity normally associated with much larger systems. With its ease of use and simplicity to install, Syncro AS is straightforward to understand for installers, commissioning engineers and end users alike. Using the latest microprocessor, it provides a flexible control system with high reliability and integrity. Features Expandable from one to two loops* Being a multi-protocol panel, enabling choice to our customers, Syncro AS supports Apollo, Network up to 64 panels* Argus Vega and Hochiki detection, making it ideal for small and medium sites that require Two programmable sounder circuits advanced fire sensing and evacuation options. It can be expanded and networked to become Five programmable inputs part of much larger systems if the need arises, providing a future proof solution for any Three programmable relays size of installation. 3A power supply Up to 512 additional programmable I/O via Syncro AS is also available as a Lite version offering a cost-effective solution for smaller Syncro I/O modules* standalone installations requiring only one detection loop. Powerful, network wide cause and effects* Sensitivity adjustment and Drift Compensation Compatible with View repeaters* Supports Apollo, Argus Vega and Hochiki protocols Stores 500 last events in event log Installer friendly, removable equipment chassis Different language and character set variants available Approved and certified to EN54-2/EN54-4 Please note * These items not available on Syncro AS Lite panel If you require a Printer with a Syncro AS panel please view Datasheet 21
Syncro Syncro AS Network Network Diagram Diagram Supports all Syncro I/O RS485 High Integrity Configurable Network modules. High Integrity Configurable Network K555 Network Card Required RS232 Ockular Fire System Management Platform Syncro AS Analogue Addressable Control panels are supplied Control Panel with 1 or 2 detection loops (if fitted) Loop 2 K555 Network Card Required I/O Loop 1 Syncro AS Analogue Addressable Control Panel Each loop is capable of hosting up to: 126 devices (Apollo) or K555 240 devices (Argus Vega) or Network Card 127 devices (Hochiki) Supports all Required Syncro I/O modules. RS485 RS232 Syncro AS Analogue Addressable Control Panel 22
RS485 K560 K547 K546 K545 16 Channel 8 Way 6 Way 4 Way Conventional I/O Board Relay Board Sounder Board Zone Board 24V DC 24V DC 24V DC 24V DC I/O K555 Network Card Loop 1 Loop 2 Required (if fitted) Syncro View Local LCD Repeater Syncro AS Analogue Addressable 24V DC or Control Panel 230V AC Each loop is capable Up to 64 Panels/ of hosting up to: Repeaters can be 126 devices (Apollo) or added to the network. 240 devices (Argus Vega) or K555 127 devices (Hochiki) Network Card Required Syncro Ident Programmable LED The Syncro system is compatible with Apollo, Indication Panels Argus Vega and Hochiki protocols. Panels of any of the above protocols can be 24V DC or used on the same network. 230V AC Syncro AS Analogue Addressable Control Panel A mixture of up to 32 devices (including Syncro View, Ident and Matrix) can be fitted to each panel on the RS485 serial Syncro Matrix interface. The maximum number of Syncro View Fire Alarm Mimic panels on a single RS485 Display System serial interface is 15. Vizulinx 24V DC or Fire Alarm Management 230V AC Solution 23
Syncro Repeaters Analogue Addressable Fire Control Panel Repeaters Syncro View The Syncro View fire alarm repeater provides a cost effective, simple and convenient method of extending the controls and indications of the Syncro AS fire alarm control panel to other locations. The large, graphic LCD, brightness LED indicators and full set of controls duplicate the indications and controls on the Syncro AS fire alarm control panel at up to 15 additional locations via a (separate to the Syncro AS network) simple, two-wire serial data connection. Ideal for locations where a control and indication point smaller than a full fire alarm control panel is required, the Syncro View is available in either a 24V DC powered option (which can be powered via an additional two cores from the Syncro AS control panel auxiliary 24V DC supply) or a 230V powered option with local battery back up. 24
Analogue Fire Detection Features Up to 15 annunciators can be connected to each Syncro AS fire control panel Large liquid crystal display (240 x 64 pixels) High brightness LED indications Internal sounder Replicates all Syncro panel controls Simple, two-wire serial connection Removable electronics for easy installation 24V DC or 230V AC power options Low power consumption Multi language options Connection monitored by Syncro AS fire control panel 25
Addressable Ident Analogue Addressable Fire Control Panel Repeater 26
Analogue Fire Detection Addressable Ident panels provide a compact and attractive display for multiples of 24 indications from a Syncro AS or Taktis Fire control panel. As with all inputs and outputs on the Syncro AS and Taktis Fire, each indicator is fully programmable to indicate a variety of events as well as being fully programmable via cause and effects to operate in response to logically connected inputs. Each indication defaults to a zonal fire indicator but may be configured via the Loop Explorer configuration utility to operate upon any event type or combination of inputs. Requiring only a low current 24V power supply and a two-core data connection to the fire panel, the addressable Ident panels can be installed quickly and easily to provide supplementary information on the status of the fire alarm system with the minimum of cost and effort. Features Eight and 24 LED versions available as standard Large versions available to special order Up to 16 x 24 way Addressable Ident can be connected to each fire panel Programmable flashing or steady states Red, yellow or green indications/options Common Fire, Fault and Disabled indication Customisable label identification tags Buzzer with silence control and re-sound Lamp test control Low power 24V DC supply Multiple language options 27
Addressable Matrix Intelligent Fire Alarm Mimic Display System The addressable Matrix system uses flexible, fibre optic light guides to illuminate areas on a floor plan, laid over a high-resolution grid. This unique system dispenses completely with wiring and enables indicators to be moved, removed or added on site without the need for any wiring. Ideal for buildings such as hospitals where the building layout may evolve over a period. As the building changes, so too can the Matrix, with very little cost or disruption. The addressable Matrix can be supplied with or without common LEDs and controls. Optional LEDs indicate Power On, Fire, Fault and Disablement and optional controls are for Alarm Silence, Buzzer Silence, Lamp test and Reset. It provides a clear, geographical indication of fire alarm or other system activation enabling speedy identification of the source of an alarm or other events. Where the requirements of the installation exceed the standard range of the Matrix panels, completely bespoke solutions are available. The enclosure size, mimic viewing area, colour and finish can all be tailored for the individual requirements of the site, including the option of surface or flush construction. Up to 32 mimic PCB’s can be connected to a single Syncro AS and Taktis Fire panel giving a total of 504 LED’s that can be individually configured via the standard loop explorer configuration software. To increase the flexibility of this product further, the LED extension boards are available with yellow or green indicators fitted. 28
Analogue Fire Detection Features Up to 504 LEDs can be controlled from any Taktis Fire or Syncro AS panel Full colour printing Available in a range of standard enclosures to suit any applications Bespoke sized units can be made upon request Choice of Red, Green or Yellow LED’s Available with or without controls The addressable Matrix can easily be upgraded on site with minimal cost and effort EN54-4 approved PSU (optional) Configured via standard Loop Explorer Software 29
Vizulinx Alarm Management Solution Vizulinx is a fire alarm management solution which Modbus and BACnet connectivity enables a simple, enables you to monitor your fire systems remotely. low-cost integration into building management systems and the ability to monitor equipment via Highly configurable using an embedded web server 16 switched inputs. Configuration of custom and simple configuration wizard, it can be used to messages allows support for conventional fire and pass fire system events via e-mail, SMS, Modbus and extinguishing systems. BACnet message format using an IP connection. For managers of multiple sites, Vizulinx keeps them Upgrade options to interface with two-way updated on fire alarm activity providing convenience radio systems, ESPA telephone and pager units. and time-saving efficiencies. Speech diallers are available and future connectivity via GSM will be provided for sites where internet This application is ideal for building managers and connectivity is not available. service providers. Event notifications are triggered and processed immediately, and email or mobile phone messages can be routed to any number of recipients based on the Fire Alarm event types. These include fire, pre-alarm, fault, disable, in test, technical alarm and security. As events are sent immediately, this reduces false alarms as it allows alarms to be investigated before sounding to prevent unnecessary evacuation. 30
Analogue Fire Detection 31
Sigma CP Conventional Fire Alarm Control Panels Sigma CP Overview The Sigma CP range of conventional fire control panels are designed for the most demanding of conventional fire detection and alarm system applications. Easy to install, the Sigma CP is available with two, four or eight detection zones in standard or installation saving, ‘two-wire’ versions. The extensive range of configuration features available ensure suitability for new installations or panel replacements on older systems. Configuration options are stored in non-volatile memory and are easily accessed via an intuitive user interface, which enables the configuration data to be viewed and changed efficiently. Sigma CP control panels are compatible with most standard, conventional detectors, call points and sounders and are also compatible with ‘two wire’ detector bases from Apollo and Hochiki. 32
Conventional Fire Detection Powerful Features fail or are disconnected after the panel has The simple and intuitive programming interface been configured to recognise them. on Sigma CP panels allows simple configuration Two-wire versions of Sigma CP can have of many parameters by entering simple codes detectors, call points and standard, polarised which are listed on the inner door look up table sounders connected to the same two core Features and in the operation and maintenance manual. cable, greatly reducing installation time and Two-wire and standard versions in two, four or Configurable options include sounder delays, cost on some installations. eight zones short circuit triggering of zones, non latching Compatible for use on BS5839: Part 1: 2017 zones, silent zones, I.S. barrier compatible These two-wire versions also provide the installations zones and system disablements. capability of zonal sounders which may be Two-wire repeaters and ancillary boards configured as zonal alarm (sounders operate Fully programmable using simple menu options Connectivity only in the zone of activation), common alarm • Adjustable sounder delay time Sigma CP control panels have a dedicated (all sounders in all zones operate) or two-stage • Sounder configuration options ‘two-wire’ serial bus for connection of repeater alarm (sounders are continuous in the zone of • Zonal sounder delay detectors only panels, ancillary relay boards or zonal sounder activation and pulsing in all other zones). • Zonal sounder delay call points only extension boards. Up to seven units may be • Coincidence input selection connected to the serial bus which can be up to Sigma CP panels combine compact and practical • I.S. Barrier selection by zone 1200 metres in length. All units connected to styling with the programming power and • Short circuit fire by zone the serial bus are fully monitored and the connectivity required for the most complex • Non latching zones control panel will announce a fault condition and demanding conventional fire alarm • Silent zones showing the address and type of any units that system installations. • Zone input delay • General panel configuration Simple, single board construction Installer friendly Compatible with wide range of detection devices Two monitored sounder outputs Three Amp power supply Auxiliary power output Fully certified to BS EN54-2 and BS EN54-4 33
Sigma CP-A AlarmSense® Conventional Fire Alarm Control Panels The Sigma CP-A AlarmSense® range consists When sounder or sounder beacon bases are of a series of conventional, two, four and eight selected for local alarm mode, alarms are zone fire alarm control panels. restricted such that only the sounder connected to the activated detector will operate initially. The AlarmSense system enables all detection and The panel will attempt to reset the activated sounder devices in a given zone to be wired to the detector after a time delay and if successful same pair of cables, greatly reducing the cabling no further alarms are sounded. If the detector and installation requirements and hence costs. re-activates after being reset, a general alarm will sound throughout the premises. The AlarmSense range of devices includes smoke and heat detectors, call points, base sounders, Activation of a second detector or a call point base sounder/beacons and relay units – all wired will sound the general alarm immediately. to the same pair of cables. The alarm verification feature of the Sigma CP-A Having sounders and sounder beacons installed control panel greatly reduces the risk of unwanted on the same cabling as detectors and call points alarms or call outs while still providing secure, allows all systems to be configured for common, high quality fire protection throughout the premises. zonal or two-stage alarms by simply setting one of the panels configuration options. All control panels have an integral, 3 Amp mains powered battery charger and power supply capable Selection of the AlarmSense local alarm feature of providing power to the most demanding at sounder or sounder beacon bases invokes the of applications. alarm verification feature. This is particularly useful in Houses of Multiple Occupation such as student accommodation or nursing homes. 34
Conventional Fire Detection Features Allows systems to be installed in accordance with BS5839: Part 6: 2013 installations Two-wire systems, reduces installation cabling Two-wire repeaters and ancillary boards via serial bus Fully programmable using simple menu options Adjustable sounder delay time Sounder configuration options Zonal sounder delay for detectors only Zonal sounder delay for call points only Coincidence output via ancillary board Short circuit fire selectable by zone Non-latching selection by zone Silent zones (common sounder outputs) Zone input delay for sprinkler system connection AlarmSense® local alarm feature supported Simple, single board construction Installer friendly Compatible with all AlarmSense® devices Two conventional monitored sounder outputs 3 Amp power supply Auxiliary power output Fully compliant with BS EN54-2 and BS EN54-4 35
Sigma CP System Diagram Sounder 2 2 Core Power – 24V DC 2 Core Data – RS485 Sounder 1 Zone 2 Zone 1 Sigma CP – EN54-2/4 Approved Control Unit 230V AC 36
Ancillary Board Ancillary Board Sigma CP-R Repeater Panel 24V DC or 230V AC Plant Controls Sigma CP-R Repeater Panel Vizulinx 24V PSU Sounder Board Fire Alarm Management Solution 37
Sigma XT Extinguishant Control Panel The industry leading Sigma XT extinguishant releasing panel, installed extensively in thousands of premises globally, offers outstanding value and performance for all small to medium fixed firefighting installations. With three detection zones as standard, extinguishant release can be configured to activate from any combination of detection zone inputs. Sigma XT panels are both robust and easy to install having all the electronics mounted on a single, easily removable, steel plate. 38
Sigma XT Network Diagram Extinguishant System Control Common Fire-Cryer Plus 1st and 2nd stage voice sounders Manual Release Hold Off Unit Released Pressure Switch Door Interlock Activate Extinguisher Low Pressure Switch Extinguishing Control PCB Sigma XT - EN12094-1 Approved Control Unit Features Vizulinx Any single zone or any combinations of zones can be configured to release Fire alarm management 4 Core (FP200 max. length 1200m) solution Configurable first stage sounder delays Hold Off Unit BMS 2 Core Interface Configurable detection delays Zero time delay upon manual release option 2 Core Door Interlock Compatible with I.S. barriers Non-latching zone input option to receive signals 4 Core Status Unit Ancillary Board from other systems such as aspirating equipment Addressable House Fire Alarm Countdown timer shows time remaining until release Supports up to seven, four-wire status indicators Detection Zone 1 Detection Zone 2 Detection Zone 3 Approved and certified to EN12094-1, EN54-2 Ancillary Board Status Unit Status Unit Status Unit and EN54-4 UL and FM Approved version also available 39
Sigma ZXT Extinguishant Control Panel A development of its proven Sigma XT range, the A sophisticated, dynamic LCD, which supplements Sigma ZXT provides controls and indications for a the LED status indicators, provides detailed single-area extinguishing release system, enabling information on panel status including fault targeted extinguishing that limits damage and conditions, alarm conditions and extinguishing reduces costs. Three conventional detection zones release countdown. If dynamic mode is chosen, provide the alarm ‘trigger’ required to activate the the display changes colour in relation to the panel release of extinguishant, and the system can be status, providing immediate and clear visibility of configured to release the extinguishant on an status conditions. These are as follows: alarm from any single zone or combination of White – Normal condition multiple zones. Red – Fire condition, Released condition Red flashing – During countdown to the released The system, compliant with EN12094-1, can condition also be configured to provide two extinguishing Yellow – Fault condition, Disabled condition outputs, either working together as common and Test condition outputs or as main and reserve outputs. The Green – Access level 2 latter results in the connection to two sets of Turquoise – Access level 3 extinguishing gas cylinders, which enables the customer to return a system to a functional state, While not in dynamic mode, the LCD will be white quickly, following a release. regardless of status. The Sigma ZXT has an event log which records To compliment the Sigma ZXT a range of status event data from the panel such as alarms, faults, indicators which match the look of the Sigma ZXT configuration changes etc. along with a time and panel fascia. Status units can be located at any date stamp. This historical visibility is critical for access point to the risk area notifying approaching diagnostics, identifying the cause of alarms and persons of system status, as well as providing faults, as well as reasons for activations. Up to 1000 optional Auto/Manual key switches and Manual events can be stored within the panel which can be Release pushbuttons. viewed through the LCD or can be downloaded and saved using Kentec’s LE2 software. 40
Extinguishant System Control Features ingle area extinguishing panel S Dual extinguishing outputs Event log Dynamic LCD Display Compatible with I.S. barriers Non-latching zone input option to receive signals from other systems such as aspirating equipment Countdown timer displays time remaining until release Supports up to seven, four-wire status indicators Sigma ZXT status units Compatible with SI status units Larger enclosure option is available Approved and certified to EN12094-1, EN54-2 and EN54-4 41
Sigma XT+ Extinguishant Control Panel Multi-Area Addressable The Sigma XT+ range combines Sigma CP remotely in separate enclosures and connected to conventional fire detection from two to eight zones. Sigma CP panels via this serial interface to provide With highly configurable extinguishing control central fire detection and control with distributed modules, it provides an integrated control extinguishing systems. solution for extinguishing systems with up to four protected areas. Sigma XT+ modules may also be mounted separately from fire detection and control equipment and The fire detection section connects to the activated by addressable output modules or extinguishant control modules via a serial link which volt-free contacts from other systems via two allows secure, bi-directional transfer of data between monitored activation inputs. the two. Sigma XT+ modules may be mounted 42
Extinguishant System Control Features Two, four or eight detection zones One to four extinguishant areas Dual extinguishant outputs for each area (configurable as Main/Reserve) F irst and second stage sounder outputs for each area First and second stage volt-free changeover contacts for each area Released volt-free contact per area Fault volt-free contact per area Programmable extinguishant delays Programmable output duration Countdown indicator shows time until release in seconds Mode select and manual release controls per area Monitored remote manual release input, Abort input & Hold input Approved and certified to EN12094-1, EN54-2 and EN54-4 43
Syncro XT+ Extinguishant Control Panel Multi-Area Addressable Syncro XT+ multi area addressable control panel enables extinguishing systems to use all the features and benefits of the more sophisticated detection techniques provided by addressable fire detectors. It also includes other benefits of analogue addressable systems such as control of loop connected sounders, beacons and input/output modules. With up to 16 zones of addressable detection over one or two loops it ensures every detector can contribute to the extinguishant release. The Syncro XT+ has up to four extinguishing areas and two releasing outputs per area which can be controlled via simple coincidence detection or via more complex cause and effects configured by the Loop Explorer configuration programme. Each extinguishant area has a comprehensive set of inputs and outputs and is configurable via the Loop Explorer configuration programme. All extinguishant areas may have up to seven serially connected Sigma Si status indication and control units, or ancillary relay boards connected via a simple four-core cable. With the addition of a Syncro network card, Syncro XT+ control panels can be networked to provide scalable extinguishing systems for all sizes of installation. 44
Syncro XT+ Network Diagram Extinguishant System Control Typical Extinguishing Area Connections Fire Area Connections Syncro Si Addressable Status Unit & Syncro Common Fire-Cryer Plus Addressable Hold Off A mixture of up to 32 devices Unit on Apollo loop only. (including Syncro View, Ident 1st and 2nd stage and Matrix) can be fitted to each voice sounders Extinguishing Control panel on the RS485 serial interface. PCB The maximum number of Syncro Loop 1 Loop 2 View panels on a single RS485 serial interface is 15. Each loop is capable of hosting Main Release I/O up to: 126 devices (Apollo) or 127 devices (Hochiki) Optional Reserve Release Can be Low Pressure configured Syncro Matrix as 1st stage Fire Alarm Mimic sounders (if fitted) Display System Loop 1 Loop 2 Release Pressure 24V DC or 230V AC Abort Unit Features I/O Syncro Ident Up to four extinguishant areas Programmable LED (custom build options are available) Hold Off Unit Indication Panels Dual extinguishant outputs for each area 24V DC or 230V AC Manual Mode Switch (configurable as main/reserve) K555 Network Card Required Manual Release First and second stage sounder outputs RS485 Syncro View Local LCD Repeater for each area 24V DC or First and second stage volt-free changeover contacts for each area 230V AC K1822 Sigma Si Weatherproof Sigma Si Ancillary PCB Status Unit Status Unit Syncro XT+ K545 Released volt-free contact per area Up to 7 per Up to 7 per Multi Area Addressable Fault volt-free contact per area area. area. Extinguishant Control Panel 4 Way Conventional Zone Board 24V DC Programmable extinguishant delays High K555 K555 Programmable output duration Integrity Network Card Network Card Required Required K546 Countdown indicator shows time until 6 Way Configurable Sounder Board 24V DC Network release in seconds Mode select and manual release controls RS485 K547 8 Way Relay Board 24V DC per area Serial connections for Sigma Si status Control panels are supplied Up to 64 Panels with 1 or 2 detection can be added to Syncro XT+ loops and 16 the network. units and ancillary boards (K588) zone indicators. Multi Area Addressable Extinguishant Control Panel The Syncro XT+ system is compatible K560 Approved and certified to EN12094-1, with Apollo, and Hochiki protocols. Syncro XT+ Syncro XT+ 16 Channel panels of either the above protocols can be networked Multi Area Addressable I/O Board Extinguishant Control Panel 24V DC EN54-2 and EN54-4 together. Vizulinx Fire alarm management solution 45 Addressable Syncro XT+ Multi-Area Extinguishant Control Panels
Sigma Si Extinguishant Status & Ancillary Units Sigma Si is a range of system status indicator units for For systems where local control of the Automatic/Manual use with Kentec Sigma XT, Sigma XT+ and Syncro XT+ mode and or a Manual extinguishant release control are extinguishant releasing control panels. required, units are available with these controls fitted. The Sigma Si range of status indicators provides All models have monitored inputs for the remote detailed status information for Sigma XT and Sigma XT+ connection of Automatic/Manual mode and Hold extinguishant release control equipment. All models switches and are provided with a large, LED display provide high brightness, LED indication of Manual Only, which shows a countdown of the time remaining Automatic and Manual, Hold Operated, Disabled, Imminent until the extinguishant is released in seconds. and Released conditions. Sigma Si 10 lamp version also has zonal fire indicators and a common fault indicator. 46
Extinguishant System Control Hold-Off Units Sigma Si Hold off units are available with red or green actuators (BS 7273-1 recommends white with red button) and are mounted in a single gang, surface mounting enclosure. For flush mounting, the enclosure may be discarded, and the unit mounted to a standard UK single gang electrical back box. The unit has a durable, shrouded push button to prevent accidental operation, and a simple two-wire connection to Sigma XT, Sigma XT+, Syncro XT+ or Sigma Si status units is required. Sigma Si Hold off units are fitted with normally open and normally closed contacts to allow operation with monitored and unmonitored systems. 47
Fire-Cryer Plus Voice Sounders The Fire-Cryer Plus voice sounder and visual indicator It features a sound output of 100dB(A), with exceptionally is an additional accessory for the Sigma XT, Sigma XT+ and low current, averaging at 20 mA. Rocking armature Syncro XT+ extinguishing control panels. An alternative to technology provides highly intelligible speech with the electronic sounders/bells and strobes, when used together Fire-Cryer Plus being industry approved EN 54-3 standards. with the extinguishing controller module it provides a clear and concise message to the building occupants. The Fire-Cryer Plus technology is easily integrated with Kentec’s range of Sigma extinguishing panels via an Four extinguishing system specific messages are provided extinguishing controller PCB. – 1st stage alarm, 2nd stage alarm, gas release imminent, gas release confirmation and hold button activation – thus Compact and easily installed, the voice sounder avoiding potentially confusing electronic sounder and bell functionality brings an added layer of safety to a notifications in critical environments. wide range of applications where spoken announcements are beneficial, for example data centres and communications environments where mission critical systems need to provide zero downtime. 48
Extinguishant System Control Features Fully compatible with the Kentec range of extinguishant control panels Four pre-programmed voice messages Sound output of 100Db(A) max Exceptionally low current, averaging at 20mA Approved to EN 54-3 industry standards 49
Safe-Point Emergency Voice Communication (EVC) An EVC (emergency voice communication) system The Equality Act (2010) ensures that disabled people (commonly known as a Disabled Refuge System) allows are treated equally, this includes responsibility on all firefighters and staff to communicate, with persons businesses to ensure that everyone has access to buildings awaiting safe evacuation in Refuge Areas, during and services. emergency situations. The provision of a safe refuge area enables the person It enables people who seek assistance to have a constant who requires assistance to make their way to the two-way communication with emergency services from closest designated area and await evacuation. a number of points throughout a building or building complex, particularly in a fire emergency situation. There are certain standards that a safe area must adhere to. These are described in building regulations BS9999:2017, BS5839-9:2011 and BS8300:2009. All of these standards ensure that buildings are designed to meet the needs of disabled people. Kentec Electronics Safe-Point EVC provides the communication from the safe refuge area to the emergency services. 50
Emergency Building Evacuation Systems Safe-Point Refuge Call Outstation Outstation Type B can be used as a disabled refuge call point or a Fire Telephone. This is defined is BS 5839 part 9. A call is made by pressing the large momentary push button. This will then illuminate the panel mounted ‘call registered’ red LED and initiate a conventional telephone call tone from the panel loudspeaker. Features Outstation Type B. Hands free unit Full duplex speech Photo luminescent front panel Braille identification Induction Loop Flush mounted Vandal resistant 51
Power Supplies (PSU) For Fire Detection, Alarm and Fire Protection Systems The K25000 range of 24V DC power supplies K25000 power supplies can be fitted with an optional are designed to meet the exacting requirements dual output board to provide redundant power paths of fire detection and alarm systems, and fire for fire alarm applications, and are available in a protection systems. range of enclosures to accommodate different battery sizes. These part numbers are prefixed with KD. All models charge sealed lead acid batteries using sophisticated, temperature compensated charging and monitoring techniques to keep the batteries in the best possible condition. Over depletion of batteries is prevented by a low battery voltage disconnection function which removes the load from the batteries when their terminal voltage reduces to a level which would damage them. A low battery voltage fault warning is given when the batteries reach the minimum terminal voltage recommended by the battery manufacturers. A high series resistance in the battery supply circuit, which would allow the power supply output voltage to fall outside of the specified range, is indicated as a fault condition. 4520
PowerSupplies Power Supplies Onboard LED indicators are provided to indicate the Unboxed or caged power supplies for incorporation status of the unit. An onboard header is available into other equipment are available as follows: to extend status signals to other systems and a volt-free relay contact operates upon any fault S2014 – 2.6A output condition or total power failure. S406 – 5.25A output S408 – 10.25A output Enclosures are designed to match both Sigma and Syncro AS fire panel ranges and are constructed from 1.2mm mild steel and are finished with epoxy powder coating. The K25000 boxed range is available in the following power outputs: K25250 range – 2.5A output and up to 12Ah batteries K25400 range – 5.25A output and up to 26Ah batteries K25800 range – 10.25A output and up to 45Ah batteries 531 4
Sigma DocBox Designed to provide a convenient method of storing system test records, manuals, configuration files, keys and other documents or access arrangements for fire alarm and protection systems, the Sigma DocBox is finished and constructed in a similar manner to Sigma and Syncro fire alarm control equipment. Available as standard, deep or extra deep enclosure versions, and in grey and red colours, DocBoxes are available to suit any Tamper Vision Resistant Window size of installation. The Tamper Resistant Vision Window is perfect for public areas where restricted access is necessary to The DocBox also doubles up as a Key Box prevent damage and unauthorised operation of the providing 7 easily accessible formed key hooks control panel. The cover features a fully welded steel inside the enclosure and is itself lockable using construction and key lockable inner door making it a standard fire control panel key. robust and secure. The Vision Window is available from stock, fully assembled, and can be fitted on site in minutes by simply removing the hinge pins on the existing enclosure and removing the lid before fitting the new Vision Window cover and hinge pins. Control panels can also be supplied pre-fitted with the Vision Window on any M2, H2, M3, and H3 size control panels. 4542
Miscellaneous Items Relay Boards Easy to fit and wire for additional control functions or to expand the capability of existing relay outputs, these simple boards contains either one or four 24V DC relays, which can be used for any extra-low voltage switching applications. Each relay has two changeover contacts, and an LED indicator to show when the coil is energised. The coils of the relays are common to the positive supply and the relays can be operated individually by switching a negative to the numbered coil inputs. The contacts are suitable for switching a maximum of 30V DC and 2 Amps. The current consumption of the unit when operated from a 24V supply is approximately 25mA per relay. 55
Audio Visual A range of indicator units with either red or yellow indicators to provide an audible and visual status of alarms, isolations or other functions. These units are available with a keyswitch to silence the internal buzzer or a keyswitch to illuminate the indicator and buzzer. A volt-free contact is provided when the keyswitch is operated for ancillary control functions. The units are mounted in a durable steel enclosure that has the same plate fixing centres as a standard UK single gang electrical box, enabling the unit to be easily flush mounted if required. Remote Indicator Unit Remote Indicator Units provide an extension for LED indicators on hidden detection devices to allow their status to be observed without having to expose the detection device itself. All units have dual, bright LED indicators with a wide viewing angle that flash alternately to attract attention, and are available mounted to square or round metal plates for fitting to standard electrical back boxes. They are finished in white, durable epoxy powder and printed in red with ‘FIRE ALARM IN CONCEALED SPACE’. Other printing options are available upon request. Remote indicators are compatible with all types of conventional and addressable detectors. 56
Miscellaneous Items Warning Signs Powered by a nominal 24V DC supply, the illuminated warning signs employ the very latest in LED technology to provide a high reliability, high brightness, audio/ visual warning indication unit to supplement mandatory alarm warnings. The brightness of the sign remains constant over its entire operating range of 15 to 30 volts DC due to the unique ‘power boost’ circuitry employed. This ensures that even with a system running on depleted batteries, all signs remain at full intensity. A range of standard text signs are available and fully customised text and languages are easily accommodated. The large display panel is backlit with high intensity white LEDs to provide a high contrast indication in a range of different colours. A split-level function allows the top and bottom halves of the sign to be illuminated independently via separate inputs or by reversing the supply voltage, enabling two-stage messages to be displayed if required. The internal buzzer can be enabled or disabled via configuration switches and it can be silenced via a two-wire remote input. The enclosure is slimline and attractively finished in a durable, neutral epoxy powder coat. 57
Taktis® UL Fire Analogue Addressable Control Equipment Taktis® UL is Kentec’s most powerful and The modular nature of Taktis UL allows all field sophisticated analogue addressable fire panel. wiring to be connected to a passive motherboard Intelligent and technically robust, it has enhanced enabling addition, re-configuration or replacement integration and networking capabilities to meet the of all electronic hardware without the need to current and future needs of small to larger buildings disconnect any field wiring. This modularity and installations. also allows each panel to be customised with addressable loop detection circuits, conventional Initially configured as a fire detection and alarm detection circuits, relaycards, additional sounder system, the flexibility of Taktis UL is such that it can outputs or programmable I/O modules as required. be re-configured to realise many other control and indication applications, with direct integration into As a truly open protocol panel it offers installers intelligent buildings. and their customers maximum flexibility in systems’ design, site-customisation and in the Available in four and eight slot variants, Taktis UL third-party devices that they use. Not only does fire control panel ranges from two to 16 detection Taktis UL provide solutions to the most technically loops. Taktis can network up to 128 panels, challenging applications in life safety, it will also making it ideal for the largest sites such as schools, deliver added value, market advantage and a hospitals, multi-site retail/supermarkets, competitive edge to your business. critical infrastructure and major commercial and industrial facilities. Multiple protocols can be supported on each panel to give installers and end-users maximum choice in their systems’ design, and the scalable nature of the product provides the highest level of future- proofing and networking possibilities. 58