Insulated Panels New Zealand Kingspan Lo-Pitch/Curved Roof Panel Product Data Sheet KS1000 LP/KS1000 CR Roof Panel
2 Insulated Panel KS1000 LP/CR Lo-Pitch/Curved Roof Panel Systems Product Data Sheet Kingspan Lo-Pitch/Curved Roof Panel KS1000 LP/CR Product Data Sheet Kingspan roofs present a superior system compared to conventional multi-part site assembled systems. They are quicker to install, require less manual labour and provide guaranteed thermal performance. Lo-Pitch: Ideal for all applications where the roof Curved: Ideal for curved roofs with a minimum pitch is 2° or more after deflections radius of 150m Applications The Lo-Pitch (KS1000 LP) roof panel is suitable as a roof product on all building applications, and can be used on roof slopes of 2º and above. The Curved (KS1000 CR) roof panel is suitable as a roof product on all building applications, and can be used on curved roofs with a minimum radius of 150m. The hidden fixing and concealed side joint provides a robust and modern roofing profile. Manufacture Available Lengths Panels are manufactured in a Kingspan owned facility in the UK. Lead times vary depending on the colour and coating chosen. Standard lengths are from 2m to 11.8m including endlap/gutter Please check with Kingspan at time of ordering for current lead cutback. (Eg. 11.725m + 0.075m end lap). times. Factory made cutbacks are available in 0.075m or flush. Panel Performance A - Core Thickness (mm) 45 60 80 100 B - Overall Dimension (mm) 80 95 115 135 R Value (m2.K/W) 2.17 3.23 4.00 5.00 Weight kg/m2 0.5/0.4 steel 9.70 10.30 11.10 11.90 1000mm Cover Width External weather sheet 52.5 62.3 52.5 51.3 52.5 36.5 B A Internal liner sheet Kingspan Ltd, 97 Montreal Street, Christchurch Tel +64 3 260 5530 | 0800 12 12 80 Email info@kingspanpanels.co.nz New Zealand Web www.kingspanpanels.co.nz Q2 2021
KS1000 LP/CR Lo-Pitch/Curved Roof Panel Insulated Panel 3 Product Data Sheet Systems NZBC Compliance Fire Performance The KS1000 LP/CR panel has been used around New Zealand, on The KS1000 LP/CR panel has been rigorously tested to both many building types for in excess of 15 years. NZ and international building standards and the standards expected of the insurance industry. The KS1000 LP/CR panel is compliant with the following clauses of the NZBC, when Kingspan standard details are utilised: Internal Surface Finish (NZBC C.4.17.1) B1 Structure B2 Durability C Fire Standard Details Firewall Details E2 External Water H1 Energy Efficiency Group 1S N/A Materials Insurance Exterior Weather Sheet: Kingspan KS1000 LP panels are approved by FM Global to the – 0.5mm thick S220GD + ZA hot dip zinc/aluminium Galfan following Approval Standards: steel to BS EN10346: 2009 – FM4880 - Class 1 Internal wall and ceiling – Colours as per the Kingspan UK Spectrum Colour Collection panels without height restriction www.kingspanpanels.co.nz – FM4471 - Class 1 Roof panel systems Insulation Core: – Polyisocyanurate (PIR) with zero Ozone Depletion Potential Kingspan KS1000 LP/CR panels are LPCB Certificated PIR (Zero ODP). – PIR foam is a thermosetting material. It does not melt, flow – LPS 1181 Part 1: Issue 1, series of fire growth or drip when exposed to fire. It will form a strong char that tests for LPCB approval and is certified to LPS helps protect the foam core and prevent flame spread within 1181 Grade EXT-B the panels. 007 Internal Liner Sheet: – 0.4mm thick hot dip zinc steel coated to BS EN 10346:2009 Sprinkler Code NZS 4541:2013 – Rib Profile – Colour - Bright White with an easily cleaned surface The Sprinkler Standard NZS 4541:2013 contains levels of sprinkler protection required for buildings constructed with “Approved” – other colours available on extended lead time and price and “Not Approved” panels - refer to section 213 and Appendix – AQUAsafe 55 (White) stocked in limited quantities for K. High Humidity Environments Kingspan KS1000 LP PIR-cored panels are classed as “Approved” Fabrication: as they have FM Global approval. Kingspan also provides cover caps (all side caps have a factory applied anti condensation tape), profiled foam closers, butyl tapes, insulated gutters, and other fabrication items. Environmental Kingspan Insulated Panels produced in the UK are certified to BES 6001 (Framework Standard for the Responsible Sourcing of Acoustic Performance Construction Products) ‘Very Good’. Kingspan Insulated Panels For sound transmission reduction, Kingspan panels typically directly contribute to BREEAM/LEED credits. have a single figure weighted sound reduction index (SRI) of Rw=24dB. For New Zealand specific acoustic solutions contact Kingspan Technical Services. Frequency (Hz) 63 125 250 500 1000 2000 4000 8000 Rw SRI (dB) 20 18 20 24 20 29 39 47 25 Te Wharekura School Invercargill, NZ New build • Roof: KS1000 LP Kingspan Ltd, 97 Montreal Street, Christchurch Tel +64 3 260 5530 | 0800 12 12 80 Email info@kingspanpanels.co.nz New Zealand Web www.kingspanpanels.co.nz Q2 2021
4 Insulated Panel KS1000 LP/CR Lo-Pitch/Curved Roof Panel Systems Product Data Sheet Product Selection Assistance Quality and Durability Sales representatives are available nationwide to answer KS1000 LP/CR insulated roof panels are manufactured from queries on product options, assist with detailing, spans, colour the highest quality materials, using state of the art production swatches and other queries. They can also provide early stage equipment to rigorous quality control standards, complying budget estimates and co-ordinate the provision of project with BS EN ISO 9001 Standard, ensuring long term reliability specifications. and service life. The panels are also being manufactured under Environmental Management System Certification BS EN ISO 14001. Compliant to BS OHSAS 18001 Occupational Health and Technical Assistance Safety. Our technical team is available to provide specific advice on The KS1000LP roof panels are CE marked to BS EN panel spans, product specifications, standard and bespoke 14509: 2013. detailing, panel optimisation, fire wall options, project specific acoustic solutions, panel guarantees, thermal condensation risk calculations along with general building science cladding Product Tolerance advice. Cut to Length -5mm +10mm Kingspan Technical Services can provide ‘side by side’ assistance with regard to project detailing, attending design meetings, Liner Sheet Length -5mm +10mm providing training and undertaking site visits when required. Cover Width -0mm +3mm Thickness -2mm +2mm End Square -3mm +3mm Guarantees Kingspan will provide product guarantees on an individual project basis. Delivery & Packing Guarantees are typically up to 15 years in a non marine/ Standard Packing geothermal environment. All guarantees are subject to a maintenance regime. Specialist coatings are available for Protective film is applied to the external face. marine and other more corrosive areas. Kingspan roof panels are stacked horizontally. The number of panels in each pack depends on panel thickness. Biological Delivery Kingspan panels are normally immune to attack from mould, All deliveries (unless indicated otherwise) are by road transport fungi, mildew, and vermin. No urea or formaldehyde is used in to project site by flat bed truck for off loading by crane or fork the construction, and the panels are not considered deleterious hoist. to health. Off loading is the responsibility of the installer. Handling guidelines are available from Kingspan Technical Services. Site Installation Procedure A site assembly instruction brochure is available from Kingspan Technical Services. Yealands Estate Winery, Marlborough, New Zealand New build • Roof: KS1000 CR • Wall: KS1000 AWP • Interior Wall: KS1100 CS Kingspan Ltd, 97 Montreal Street, Christchurch Tel +64 3 260 5530 | 0800 12 12 80 Email info@kingspanpanels.co.nz New Zealand Web www.kingspanpanels.co.nz Q2 2021
KS1000 LP/CR Lo-Pitch/Curved Roof Panel Insulated Panel 5 Product Data Sheet Systems Kingspan Lo-Pitch Roof Panel KS1000 LP Installation P4 P2 2 No. Main Fasteners per P3 purlin at sides of panel P1 (minimum) 18mm x 4mm U section butyl rubber sealant Kingspan Curved Roof Panel KS1000 CR Installation P3 P4 P5 P7 P2 Stitching screw (or sealed Snap on cover cap P6 rivet) at eaves and P1 through capping end lap Anti-condensation tapes (factory-applied) Concealed through fastener Kingspan Ltd, 97 Montreal Street, Christchurch Tel +64 3 260 5530 | 0800 12 12 80 Email info@kingspanpanels.co.nz New Zealand Web www.kingspanpanels.co.nz Q2 2021
6 Insulated Panel KS1000 LP/CR Lo-Pitch/Curved Roof Panel Systems Product Data Sheet Kingspan Lo-Pitch Roof Panel KS1000 LP Span Tables Outer Sheet 0.5mm (Steel), Inner Sheet 0.4mm (Steel) Single Span Condition L Span L in metres Panel Load Thickness 1.4 1.8 2.2 2.6 3.0 3.4 3.8 Type (mm) Uniformly distributed loads kN/m2 Ultimate Limit State (ULS) Pressure 4.68 3.31 2.41 1.81 1.41 45 Suction 5.67 4.09 2.73 1.95 1.48 Pressure 6.30 4.63 3.49 2.68 2.10 1.68 60 Suction 7.78 5.22 3.48 2.49 1.89 1.48 Pressure 8.23 6.30 4.87 3.82 3.04 2.46 2.02 80 Suction 10.42 6.88 4.59 3.28 2.49 1.95 1.57 Pressure 9.84 7.75 6.13 4.90 3.96 3.24 2.68 100 Suction 12.72 8.56 5.70 4.09 3.09 2.41 1.96 Serviceability Limit State (SLS) Pressure 3.76 2.02 1.14 0.65 0.31 45 Suction 5.40 3.14 1.96 1.30 0.90 Pressure 5.12 2.96 1.79 1.11 0.69 0.41 60 Suction 7.37 4.55 2.99 2.05 1.46 1.07 Pressure 6.74 4.15 2.67 1.76 1.18 0.79 0.53 80 Suction 9.74 6.35 4.37 3.12 2.29 1.72 1.33 Pressure 8.07 5.18 3.48 2.40 1.68 1.18 0.84 100 Suction 11.68 7.91 5.63 4.15 3.13 2.41 1.89 Double Span Condition L L Span L in metres Panel Load Thickness 1.4 1.8 2.2 2.6 3.0 3.4 3.8 Type (mm) Uniformly distributed loads kN/m2 Ultimate Limit State (ULS) Pressure 4.68 3.31 2.41 1.81 1.41 1.11 0.88 45 Suction 5.67 4.09 2.73 1.95 1.48 1.17 0.96 Pressure 6.30 4.63 3.49 2.68 2.10 1.68 1.36 60 Suction 7.78 5.22 3.48 2.49 1.89 1.48 1.21 Pressure 8.23 6.30 4.87 3.82 3.04 2.46 2.02 80 Suction 10.42 6.88 4.59 3.28 2.49 1.95 1.57 Pressure 9.84 7.75 6.13 4.90 3.96 3.24 2.68 100 Suction 12.72 8.56 5.70 4.09 3.09 2.41 1.96 Serviceability Limit State (SLS) Pressure 2.06 1.37 0.99 0.75 0.58 0.46 0.37 45 Suction 1.59 1.15 0.91 0.76 0.65 0.58 0.52 Pressure 2.31 1.56 1.14 0.87 0.68 0.55 0.44 60 Suction 1.67 1.21 0.96 0.81 0.71 0.63 0.57 Pressure 2.58 1.76 1.29 0.99 0.78 0.63 0.52 80 Suction 1.72 1.24 0.99 0.84 0.73 0.66 0.60 Pressure 2.80 1.92 1.41 1.09 0.86 0.70 0.58 100 Suction 1.72 1.24 0.99 0.84 0.73 0.66 0.61 Notes: 1. Values have been calculated in accordance with AS/NZS 1170.0, and also take into account the methods described in EN 14509:2006 titled ‘Self-supporting double skin metal face insulating panels (Light coloured) - Factory made products - Specifications’, taking imposed loads (excluding snow), temperature and creep into account. 2. The serviceability limit state is defined by local buckling, bending or crushing failure at an intermediate support or the exceedance of a specified deflection limit. 3. Deflection limit for pressure loading is L/200 and suction loading is L/150. 4. The allowable steelwork tolerance between bearing panels of adjacent supports is +/- 5mm or L/600, whichever is the least. 5. The actual wind suction load resisted by the panel is dependant on the number of fasteners used and the support width as well as the fastener material. This table is based on a support width of 60mm. 6. For FM approved applications, a maximum span of 1800mm applies. 7. The fastener calculation should be carried out in accordance with the appropriate standards. For further advice please contact Kingspan Technical Services. 8. Load span tables for the panel specification not shown are available from Kingspan Technical Services. Kingspan Ltd, 97 Montreal Street, Christchurch Tel +64 3 260 5530 | 0800 12 12 80 Email info@kingspanpanels.co.nz New Zealand Web www.kingspanpanels.co.nz Q2 2021
KS1000 LP/CR Lo-Pitch/Curved Roof Panel Insulated Panel 7 Product Data Sheet Systems Kingspan Curved Roof Panel KS1000 CR Span Tables Outer Sheet 0.5mm (Steel), Inner Sheet 0.4mm (Steel) Single Span Condition L Span L in metres Panel Load Thickness 1.0 1.2 1.4 1.6 1.8 Type (mm) Uniformly distributed loads kN/m2 Ultimate Limit State (ULS) Pressure 4.61 3.78 2.96 2.29 1.62 45 Suction 4.67 4.04 3.42 3.03 2.64 Pressure 5.70 4.80 3.91 3.11 2.30 60 Suction 5.83 5.16 4.50 4.05 3.59 Pressure 7.27 6.17 5.08 4.13 3.17 80 Suction 7.29 6.58 5.88 5.36 4.83 Pressure 8.24 7.16 6.09 5.02 3.94 100 Suction 8.59 7.89 7.14 6.57 5.99 Double/Multi Span Condition L L Span L in metres Panel Load Thickness 1.0 1.2 1.4 1.6 1.8 Type (mm) Uniformly distributed loads kN/m2 Ultimate Limit State (ULS) Pressure 3.18 2.49 1.81 1.50 1.18 45 Suction 3.33 2.67 2.01 1.72 1.43 Pressure 3.50 2.76 2.02 1.68 1.34 60 Suction 3.67 2.96 2.26 1.94 1.65 Pressure 3.86 3.06 2.27 1.90 1.52 80 Suction 4.08 3.32 2.56 2.21 1.85 Pressure 4.15 3.31 2.48 2.08 1.67 100 Suction 4.43 3.62 2.82 2.44 2.05 * Servicability Limit State (SLS) does not apply to KS1000 CR Notes: 1. Values have been calculated in accordance with AS/NZS 1170.0, and also take into account the methods described in EN 14509:2006 titled ‘Self-supporting double skin metal face insulating panels (Light coloured) - Factory made products - Specifications’, taking imposed loads (excluding snow), temperature and creep into account. 2. The serviceability limit state is defined by local buckling, bending or crushing failure at an intermediate support or the exceedance of a specified deflection limit. 3. Deflection limit for pressure loading is L/200 and suction loading is L/150. 4. The allowable steelwork tolerance between bearing panels of adjacent supports is +/- 5mm or L/600, whichever is the least. 5. The actual wind suction load resisted by the panel is dependant on the number of fasteners used and the support width as well as the fastener material. This table is based on a support width of 60mm. 6. For FM approved applications, a maximum span of 1800mm applies. 7. The fastener calculation should be carried out in accordance with the appropriate standards. For further advice please contact Kingspan Technical Services. 8. Load span tables for the panel specification not shown are available from Kingspan Technical Services. Kingspan Ltd, 97 Montreal Street, Christchurch Tel +64 3 260 5530 | 0800 12 12 80 Email info@kingspanpanels.co.nz New Zealand Web www.kingspanpanels.co.nz Q2 2021
New Zealand Kingspan Limited 97 Montreal Street, Christchurch 8023 Tel: 0800 12 12 80 | +64 (0) 3 260 5530 info@kingspanpanels.co.nz www.kingspanpanels.co.nz For the product offering in other markets please contact your local sales representative or visit www.kingspanpanels.com Care has been taken to ensure that the contents of this publication are accurate, but Kingspan Limited and its subsidiary companies do not accept responsibility for errors or for information that is found to be misleading. Suggestions for, or description of, the end use or application of products or methods of working are for information only and Kingspan Limited and its subsidiaries accept no liability in respect thereof. Q2 2021