Daikin Slim Ducted type Slim Ducted - SK Sales
←
→
Page content transcription
If your browser does not render page correctly, please read the page content below
J.02 Air conditioning and heatpumps Slim Ducted Daikin Slim Ducted FDXM-F9 Indoor Unit R32 Sky-Air Daikin Slim Ducted type Slim Ducted F-Gas Certified To be able to purchase this product we must hold a copy of your company F-Gas Certification on your account. Links to accepted certification REFCOM F-Gas Brand ¾ Daikin Product ¾ Slim Ducted - Sky-Air - Indoor Unit Application ¾ Cooling or Heating Advantage ¾ Compact concealed ceiling unit, with a height of only 200mm ¾ Invisible unit as the unit is concealed in the ceiling: only the suction and discharge grilles are visible ¾ Compact dimensions, can easily be mounted in a ceiling void of only 240mm ¾ Medium external static pressure up to 40Pa facilitates unit use with flexible ducts of varying lengths ¾ Unified indoor unit range for R-32 and R-410A ¾ Auto cleaning filter option ensures maximum efficiency, comfort and reliability by regular filter cleaning ¾ Multi zoning kit allows multiple individually-controlled climate zones to be served by one indoor unit ¾ Daikin Residential controller: control your indoor from any location with an app, via your local network or internet. ¾ Voice command via Amazon Alexa or Google Assistant to control main functions such as set point, operation mode, fan speed, etc ¾ Low energy consumption thanks to DC fan motor Refrigerant ¾ R32 Features ¾ Daikin Residential Controller Control your indoor climate from any location via smartphone or tablet ¾ Fan only The unit can be used as fan, blowing air without heating or cooling. ¾ Fan speed steps (3 steps) Allows to select up to the given number of fan speed. ¾ Dry programme Allows humidity levels to be reduced without variations in room temperature. ¾ Air filter J.02 Slim Ducted 1/4 - 2021/9/3 - UK-EN WWW.SKSALES.CO.UK
J.02 Air conditioning and heatpumps Removes airborne dust particles to ensure a steady supply of clean air. ¾ Weekly timer Can be set to start heating or cooling anytime on a daily or weekly basis. ¾ 24 hour timer Can be set to start operation anytime during a 24 hour period ¾ Infrared remote control Starts, stops and regulates the air conditioner from a distance. ¾ Wired remote control Starts, stops and regulates the air conditioner. ¾ Centralised control Starts, stops and regulates several air conditioners from one central point. ¾ Auto-restart The unit restarts automatically at the original settings after power failure. ¾ Self diagnosis Simplifies maintenance by indicating system faults or operating anomalies. ¾ Multi model application Up to 5 indoor units can be connected to a single outdoor unit, even if they have different capacities. All indoor units can individually be operated within the same heating or cooling mode. ¾ Auto-cleaning filter The filter automatically cleans itself. Simplicity of upkeep means optimum energy efficiency and maximum comfort without the need for expensive or time-consuming maintenance. ¾ Multi zoning Allows up to 6 individual climate zones with one indoor unit Applicable outdoor units ¾ Type RZAG 71/100 NV1/NY1 ¾ Type RZASG 71/100 MV1 ¾ Type RZASG 100 MY1 ¾ Type RZAG 35/50/60 A ¾ Type RXM 25/35/50/60 R ¾ Type RZA 200/250 D (Twin/Triple/Quad only) V1 = 1PH & Y1 = 3PH Multi Series ¾ Type MXM-M / M9 / N Applicable controller Indoor unit has Daikin P1/P2 & F1/F2 connectivity. BRC1E53A - Hard wired controller BRC1H519W7 - Madoka controller in White BRC1H519S7 - Madoka controller in Silver BRC1H519K7 - Madoka controller in Black BRC4C65 - Wireless remote controller BRP069A81 - Wifi adaptor for connection to on-line controller Accessories KLIC-DI - KNX Interface for Sky Air and VRV systems KRCS01-4 - Remote room mounted temperature sensor KRP1B57 - Adaptor PCB for Interlock to fresh air fan KRP4A53 - Unit/group adaptor PCB for remote on/off, status indication and temperature setting K.RSS - Wireless room mounted temperature sensor and receiver RS-SE - Service and configuration tool for K.RSS RTD-10 - Enhanced function PCB for Sky Air and VRV. Duty rotation, Lead Lag control and heating interlock RTD-20 - Energy control PCB for Sky Air and VRV RTD-NET - Modbus interface PCB for Sky Air and VRV UK.FB2 - Mounting Box UK.RAC5 - Return Air Plenum for FDXM25/35F9 UK.RAC7 - Return Air Plenum for FDXM50F9 and FDXM60F9 UK.SAF5 - Supply Air Plenum for FDXM25/35F9 UK.SAF7 - Supply Air Plenum for FDXM50F9 and FDXM60F9 J.02 Slim Ducted 2/4 - 2021/9/3 - UK-EN WWW.SKSALES.CO.UK
J.02 Air conditioning and heatpumps Specifications FDXM25F9 FDXM35F9 FDXM50F9 FDXM60F9 Power input Cooling Nom. kW 0.036 0.036 0.060 0.060 Heating Nom. kW 0.036 0.036 0.060 0.060 Dimensions Unit Height mm 200 200 200 200 Width mm 750 750 1,150 1,150 Depth mm 620 620 620 620 Packed unit Height mm 266 266 266 266 Width mm 922 922 1,322 1,322 Depth mm 768 768 768 768 Weight Unit kg 21 21 28 28 Packed unit kg 24 24 31 31 Heat exchanger Length mm 500 500 900 900 Rows Quantity 3 3 2 2 Fin pitch mm 1.50 1.50 1.50 1.50 Stages Quantity 12 12 12 12 Passes Quantity 2.0 2.0 5.0 5.0 Tube type ø7 Hi-XD ø7 Hi-XD ø7 Hi-XD ø7 Hi-XD Fin Type Multi slit fin Multi slit fin Multi slit fin Multi slit fin Fan Type Sirocco fan Sirocco fan Sirocco fan Sirocco fan Air flow rate Cooling High m³/min 8.7 8.7 15.8 16.0 High cfm 307 307 558 565 Medium m³/min 8.0 8.0 14.6 14.8 Medium cfm 282 282 516 523 Low m³/min 7.3 7.3 13.3 13.5 Low cfm 258 258 467 477 Heating High m³/min 8.7 8.7 15.8 16.0 High cfm 307 307 558 565 Medium m³/min 8.0 8.0 14.6 14.8 Medium cfm 282 282 516 523 Low m³/min 7.3 7.3 13.3 13.5 Low cfm 258 258 467 477 External static pressure Nom. Pa 30 30 40 40 Fan motor Model KFD-280-44-8A KFD-280-44-8A KFD-280-65-8A KFD-280-65-8A Speed Steps 3 3 3 3 Cooling High rpm 1,270 1,270 1,270 1,280 Medium rpm 1,180 1,180 1,150 1,160 Low rpm 1,090 1,090 1,030 1,040 Heating High rpm 1,270 1,270 1,270 1,280 Medium rpm 1,180 1,180 1,150 1,160 Low rpm 1,090 1,090 1,030 1,040 Sound power level Cooling dBA 53.0 53.0 55.0 56.0 Heating dBA 53.0 53.0 55.0 56.0 Sound pressure level Cooling High dBA 35.0 35.0 38.0 38.0 Medium dBA 33.0 33.0 35.0 35.0 Low dBA 27.0 27.0 30.0 30.0 Heating High dBA 35.0 35.0 38.0 38.0 Medium dBA 33.0 33.0 35.0 35.0 Low dBA 27.0 27.0 30.0 30.0 Class IP-X0 IP-X0 IP-X0 IP-X0 Refrigerant Type R-32, R-410A R-32, R-410A R-32, R-410A R-32, R-410A Piping connections Liquid OD mm 6.35 6.35 6.35 6.35 Gas OD mm 9.50 9.50 12.70 12.70 Drain VP20 (I.D. 20/O.D. 26) VP20 (I.D. 20/O.D. 26) VP20 (I.D. 20/O.D. 26) VP20 (I.D. 20/O.D. 26) Heat insulation Both liquid and gas pipes Both liquid and gas pipes Both liquid and gas pipes Both liquid and gas pipes Air filter Type Removable / washable Removable / washable Removable / washable Removable / washable Temperature control Microcomputer control Microcomputer control Microcomputer control Microcomputer control Power supply Phase 1~ 1~ 1~ 1~ Frequency Hz 50 50 50 50 Voltage V 220-240 220-240 220-240 220-240 Dimensions J.02 Slim Ducted 3/4 - 2021/9/3 - UK-EN WWW.SKSALES.CO.UK
J.02 Air conditioning and heatpumps Dimensions Installation J.02 Slim Ducted 4/4 - 2021/9/3 - UK-EN WWW.SKSALES.CO.UK
You can also read