COLUM EC DESIGN AIR CURTAIN - INDIVIDUAL INNOVATIVE ENERGY-SAVING
←
→
Page content transcription
If your browser does not render page correctly, please read the page content below
COLUM EC COLUM EC COLUM EC COLUM EC COLUM EC COLUM EC DESIGN AIR CURTAIN INDIVIDUAL INNOVATIVE ENERGY-SAVING
COLUM EC + Aluminium profile discharge fins (drop form) for optimum airflow DESIGN AIR CURTAIN + Elegant steel-composite design high-quality powder coated or with stainless steel housing + Attractive intake grille with micro-intake grille behind it Applications With its suspended and standing versions, Colum EC is Powder coated intake grille in the same colours as the unit or particularly suited to the visible parts of modern entry areas and, stainless steel version, consisting of a perforated plate with thanks to its rounded design and low maintenance operation, micro grille behind it for easy maintenance application. will satisfy architects, planners, clients and operators. The floor Aluminium discharge grille for an infinitely adjustable, mounted vertical unit is particularly suited to revolving doors, unidirectional air stream Invisible energy connections for the since the heated airflow is discharged directly all the way down floor mounted vertical unit (discreetly bolted in place via holes in to the floor level without losing heat, thus preventing the the floor plate). formation of a "cold patch". The choice of standard RAL powder coatings or the stainless steel housing fit superbly in Heating media existing entry areas. Colum EC is used in hotels, banks, flagship Heat exchangers for different heating media stores, shopping malls, airports and public buildings. LPHW: for normal temperature LPHW 70/50 °C and low-temperature Special design LPHW 60/40 °C, other temperatures available on request. Colum EC is available in variable housing lengths up to 3 m. It is DX: DX register soldered under nitrogen for operation with simple to retrofit the floor mounted vertical unit in existing door heat pumps (only heating modus possible). High-quality heat systems. exchanger made from copper tubes, with pressed-on, extra-strong aluminium fins. The housing ELECTRO: 3-stage heat exchanger 400V, spiral form, corrosion Self-supporting steel-composite construction in a cylindrical resistant, with thermal overheating protection and switch-off shape with split sheet steel or stainless steel housing (polished delay. to grain size 240) in a round-rolled design. Screws and rivets are not visible. 2
Advantages at a glance + Made in Germany + ErP conform / EC fans + Certified by TÜV-Süd + Individual colours standard RAL colours available alternatively as stainless steel version + Individual unit lengths up to 3000 mm + Service-friendly thanks to filterless micro-intake grille + Aluminium (drop form) profile discharge fins for optimum airflow + Large throw distance, low noise, optimum shielding + Different heating media possible + Simple to install EC fans Maintenance The efficiency of the EC fans used by TEKADOOR is > 90% under Easy to clean (micro grille) without opening the unit by simply vacuuming partial load operation. This is 30–35% higher than for conven- the intake grille. The intake grille must be removed tional AC fans. This does not just increase the efficiency, but also before the revision panel can be opened. reduces the operating costs. The individually-driven EC fans with To do this, a cross-headed screw at the upper end of the intake grille integrated motor protection can intake air in both directions. They must be removed. Then the intake grille can be taken out of the lower have vibration-free bearings and are controlled using a PWM signal frame. (pulse width modulation) – and with 0-10 V for the DX. They do not just comply with Directive ErP, but actually exceed this standard. Control Electronic TEKADOOR GTC EC control unit, multifunctional with Mounting touch display, including an optional ModBus interface Floor mounted vertical unit: Problem-free mounting via holes in the A GTC 1 EC control unit is used as standard for models with LPHW floor plate directly on the finished flooring. The floor plate has ap- heating. A GTC E EC control unit is used for models with electrical propriate recesses for invisible energy supply from below. Optional: heating. The units come with 20 m preassembled and shielded data Power supply is also possible from above. cable. The GTC 1 EC 5-stage control unit includes the ability to switch Suspended version: simple mounting thanks to the M8 rivet nuts from manual to automatic and from summer mode to winter mode as incorporated on the upper side of the unit as well as standard. A solenoid valve of up to 2.5 A can be connected as an option optionally-available assembly materials. for the winter mode. With the standard GTC E EC control unit, the airflow can be selected manually in 5 stages and the heating capacity – depending on the fan level – can be selected manually in 3 stages. Each control unit includes a manual to automatic mode switch and a poten- tial-free contact for enabling via any on-site BMS or BEMS. A choice of 5-stage or stepless fan operation is offered as standard. A maximum of 10 units can be connected in parallel. 3
COLUM EC DETAILS Connections Connection box Floor mounted vertical unit Heating connections – flow and return – for easy connection to Simple electrical connection of the power supply 230 V/50 Hz the on-site heating system. thanks to the internal connection box. - Connections for the floor mounted vertical unit: either from Exception: below or above, invisible within the door air curtain. Electrical units with a heating capacity greater than 22.5 kW. - for the suspended version: on the upper side of the unit (or optionally from the side) 4
Data cable connection/interface Discharge fins Standard connection options for the data cable and an optional Discharge grille with aluminium fins (drop profile), depending solenoid valve or thermo-electric shut-off valve within the unit. on the model available in designs with double or multiple fins, Simple plug and play of the data cable. for an infinitely adjustable, unidirectional air stream. During the heating period, the fins should be tilted outwards by 10 to 15 Control: degrees to prevent cold air coming in from the outside. Input for the data cable to the control unit. In contrast, during operation in the summer, the fins are tilted inwards, so that the cooled indoor air cannot escape. Auxiliary: Output for parallel operation with other units. 5
FLOOR MOUNTED SUSPENDED UNIT stehende Geräte hängende Geräte VERTICAL UNIT stehende Geräte 80 hängende Geräte 40 J 80 40 J F F D D A A A A AUßEN TÜRE AUßEN RL VL VL RL TÜRE RL VL VL RL F E INNEN GEBÄUDE INNEN D F E stehend LINKS GEBÄUDE stehend RECHTS Modell D Zeichenerklärung A D E F J stehend LINKS stehend RECHTS Technische Änderungen vorbehalten Modell Zeichenerklärung ACHTUNG gezeichnet/signet Name Datum geändert/revision ma 21.03.2011 Technische Änderungen Maßstab vorb A D E F J Werkstoff 2000 400 80 230 150 ACHTUNG gezeichnet/signet Name Datum geändert/revision ma 21.03.2011 Pos. von Gruppe Teile 3000 400 80 230 150 Werkstoff 2000 400 80 230 Montage 150 nur auf dem Längen- variabel Kundenzeichnung Nr.: 4000 600 110 320 200 Erstelldatum Pos. von Gruppe Teile 3000 400 80 230 150 5000 600 110 320 200 fertigen Fussboden! Montage nur auf dem Benennung maß Colum 110321 Längen- Albert-Einstein-Str. 11 variabel Kundenzeichnung Nr.: 4000 600 110 320 200 Name Erstelldatum D-40764 Langenfeld 6000 600 110 320 200 Tel.: 049 (0)2173 20766-0 Kunde Blatt 5000 600 110 320 200 fertigen Fussboden! Benennung maß Fax: 049 (0)2173 20766-111 Albert-Einstein-Str. 11 Name Colum 110321 1 von 1 D-40764 Langenfeld 6000 600 110 320 200 Tel.: 049 (0)2173 20766-0 Kunde Fax: 049 (0)2173 20766-111 A = VARIABLE UNIT LENGTH * WE RESERVE THE RIGHT TO MAKE TECHNICAL CHANGES LUM Connection-ready, free-hanging door air curtain unit for visible installation above the door or as a floor mounted vertical unit. The ambient air intake for the suspended version is from above and from the side for the floor mounted vertical unit. 7
88 88 25 25 Fixing DOOR SIDE OUT IN 30 30 50 50 50 E. Connection 147 Fixing 238 ø 400 24 168 Fixing Floor 10 INSTALLATION ON THE LEFT 54 88 88 25 25 Fixing IN OUT 50 30 30 50 * WE RESERVE THE RIGHT TO MAKE TECHNICAL CHANGES 50 COL 147 E. Connection Floor plate with all relevant dimensions for a floor mounted vertical unit. Shown here installed on the left. Fixing ø 400 238 24 168 Fixing Floor 10 54 8
147 Fixing 238 ø 400 24 168 Fixing Floor 10 54 88 88 25 25 Fixing DOOR SIDE IN OUT 50 30 30 50 50 147 E. Connection Fixing ø 400 238 24 168 Fixing Floor 10 INSTALLATION ON THE RIGHT 54 * WE RESERVE THE RIGHT TO MAKE TECHNICAL CHANGES LUM Floor plate with all relevant dimensions for a floor mounted vertical unit. Shown here installed on the right. 9
COLUM EC STANDARD CIRCUIT DIAGRAM FOR LPHW ModBus interface Fr 21.09.2018 Room Temp 07:52 10°C Room temperature. Sensor installed Heat level Fan level 0/0 Automatic 0/0 Timer (optional) Hand off 1 2 3 Magnetic valve (OPTIONAL) 1 ON to input (CONTROL) next PCB M MOD Bus Address 1-9 1 2 3 4 Standard suppled L N PE 8 shielded datacable 8 (20 m) with next RJ-45 connectors Fan RJ 45 4 AUXILIAR CONTROL L2 N PE Magnetventil 230V / 50Hz L1 (OPTIONAL) L2 N PE N zum Steuerteil (CONTROL) AUX MON intern PE Adresse 1-9 Standard weiss/white imp. Anschlusskabel gelb/yellow Y 0-10 V 8 8 (20 m) mit blau/blue 0V RJ-45 Stecker PCB EC rot/red +10 V CPU AUXILIAR CONTROL 901 78 2 3 F 16 AT 45 6 Address switch AUX MON 0 = MASTER 1 - 9 = SLAVE 1 11 2 12 3 13 4 14 5 15 6 16 7 17 8 9 10 18 19 20 L N PE Connecting box Plati Frost protection thermostat Roomtemp. sensor BMS On/Off ext. Contact nicht belegt Main switch and fuses Operation CPU not used not used to be installed by third fault parties must comply q to all applicable rules and 901 3 requirements! 78 2 3 45 6 optional optional optional 230V/ 50Hz Adress Schalter 0 TECHNICAL * WE RESERVE THE RIGHT TO MAKE = MASTER CHANGES 1 - 9 = SLAVE Technical changes reserved Name Datum CONTROL UNIT GTC 1 EC gezeichnet/signet la 02.01.2019 Multilingual, menu-driven electronic control unit for TEKADOOR 1 11 2 air12curtains 3 13with 4 LPHW 14 5 heating 15 6 and16 7 17 8 Werkstoff Maßstab Frostschutzthermostat energy-saving EC fans. A standard feature of the control unit with touch display is a choice between 5-stage or stageless Pos. fan control, von which canTbe Gruppe eile selected individually by the operator. The relevant ext. Signalgeber DDC- Freigabe operatingNr.: Kundenzeichnung modes and symbols are arranged clearly on the colour display. The date, time and room Erstelldatum temperature are shown as standard. The room temperature is monitored via an internal temperature nicht belegt nicht belegt nicht belegt nicht belegt sensor inGTC I EC unit as190102 Benennung Name Kunde the control standard. Blatt 1 von 1 An easy-to-navigate menu offers a selection of different operating modes: Hand – manual operation Auto AS – automatic operation via cool down protection Auto RT – automatic operation via room temperature Auto TK – automatic operation via door contact Auto Kombi – option to combine all individual automatic modes optional optional optional An enabling contact and potential-free operation and malfunction signals are provided for control via an on-site BMS or BEMS. Errors and faults are displayed with a red „warning“ sign. By coding the control boards differently, up to 10 door air curtains can also be operated in parallel with 1 control unit, using the Master/Slave principle. The control board is preinstalled in the door air curtain unit and 20 m of preassembled data cable (connection between the door air curtainName and control unit) Datum are included as gezeichnet/signet la 07.03.2017 standard. 10 Werkstoff
COLUM EC CIRCUIT DIAGRAM FOR ELECTRICAL HEAT EXCHANGER Fr 21.09.2018 Room Temp ModBus Room temperature. Sensor installed interface 07:52 10°C Heat level Fan level (optional) 0/0 0/0 Automatic Timer Hand off K1 K2 K3 1 2 3 1 to input M ON Standard supplied q MOD Bus CONTROL shielded datacable S 60° next PCB (20 m) 1 2 3 4 K1 8 1:1 straight wired next RJ-45 Stecker K1 Fan q q q RJ 45 8 S 80° S 45° S 50° 4 AUXILIAR CONTROL L2 N PE Magnetventil 230V / 50Hz L1 (OPTIONAL) L2 N PE N zum PE Steuerteil (CONTROL) AUX MON intern Adresse 1-9 weiss/white imp. Standard Anschlusskabel 8 gelb/yellow YPWM blau/blue 0V 8 (20 m) mit rot/red +10 V RJ-45 Stecker CPU F 16 AT 901 PCB EC 78 2 3 45 6 AUXILIAR CONTROL Adress switch 0 = MASTER 1 - 9 = SLAVE q S 100° AUX MON 1 11 2 12 3 13 4 14 5 15 6 16 7 17 8 9 10 18 19 20 Blow out Temp sensor 1 2 3 L N PE K0 Room Temp sensor Frost thermostat BMS On/Off Connecting box Plati ext. Signal Operation Failure free free q q K3 K2 4 3 CPU 3~400V/ 50Hz optional optional optional 230V/ 50Hz 901 78 2 3 Mains switch and fuses 45 6 to be installed by third step 2 step 1 parties must comply step 3 = step 1 + step 2 to all applicable rules and Adress requirements! Schalter * WE RESERVE THE RIGHT TO 0 MAKE = TECHNICAL MASTER CHANGES Technical changes reserved 1 - 9 = SLAVE Name Datum gezeichnet/signet Sa 02.01.2019 CONTROL UNIT GTC E EC Werkstoff 1 11 2 air Maßstab Multilingual, menu-driven electronic control unit for TEKADOOR 12curtains 3 13 with 4 LPHW 14 5 heating 15 6 and16 7 17 8 Frostschutzthermostat energy-saving Pos. EC fans. 5-stage von fan operation Gruppe or stageless fan control – easy to adjust on the control unit Teile using the touch Kundenzeichnung Nr.: display. The electric heater can be activated in 3 stages.The relevant operating modes Erstelldatum ext. Signalgeber DDC- Freigabe and symbols are arranged clearly on the colour display. The date, time and room temperature are shown Benennung as GTC standard. The E EC room UK 190201 temperature is monitored via an internal temperature sensor in the control unit as nicht belegt nicht belegt nicht belegt nicht belegt Name Kunde Blatt standard. 1 von 1 An easy-to-navigate menu offers a selection of different operating modes: Hand – manual operation Auto AS – automatic operation via cool down protection Auto RT – automatic operation via room temperature Auto TK – automatic operation via door contact Auto AT – automatic operation via constant discharge temperature Auto Kombi – option to combine all individual automatic modes optional optional optional An enabling contact and potential-free operation and malfunction signals are provided for control via an on-site BMS or BEMS. A constant discharge temperature can be set via an optional cable temperature sensor. This enables optimisation of the shielding performance. A week timer is incorporated as standard, enabling up to 12 different switching times to be programmed per week. Errors and faults are displayed with a red „warning“ sign. By coding the control boards differently, up to 10 door air curtains can also be operated in parallel with 1 control unit, using the Master/Slave principle.The Name control board is preinstalled in Datum gezeichnet/signet la 07.03.2017 the door air curtain unit and 20 m of preassembled data cable (connection between the door air curtain and control unit) are included as standard. 11 Werkstoff
COLUM EC OPTIONAL ACCESSORIES Thermostatic Solenoid valve Thermo-electric Ceiling attachment straight-way valve shut-off valve set (Setting range + 20 °C to + 35 °C) Opens or closes the warm water 230 V / 50 Hz, normally closed. limits the discharge temperature circuit in the summer/winter On-site installation in the For problem-free, vibration free (constant supply air temperature setting of the control unit, in order heating flow. Actuated by ceiling attachment, consisting limitation). Also available as a to close the heating water circuit the summer/ winter circuit. of M8 or M10 threaded rods, 3-way valve. and save energy during summer Summer function – closed. Winter up to 1000 mm length, vibration operation or when the air curtain function – opened. dampers, turnbuckles and coun- is not working (normally closed). ter nuts. Caution: If solenoid valves are used, it is expressly recommend- ed to install a frost protection thermostat (automatically actuat- ed) and a strainer. 12
Frost protection Control unit Electronic Door contact thermostat GTC 2 EC control valve solenoid switch For monitoring LPHW heat Possibility of combination of Electronic valve with 0-10V im- In automatic mode switches on exchangers exposed to the risk various automatic operations. pulse and blow-out temperature the door air curtain in the of frost. As soon as the temper- A constant discharge tempera- sensor completely installed and preselected stage ature falls below +7 °C, the fans ture can be set via an optional wired. In combi- are switched off and an optional electronic control valve, and a nation with the GTC 2 control, a solenoid valve is opened. week timer is incorporated as preselected blow-out tempera- standard, enabling up to 12 ture is kept constant. different switching times to be programmed per week. 13
COLUM EC 2000 TECHNICAL DATA Design based on: recommended operating point intake temperature tLE = +20 °C discharge temperature tLA = +34 °C throw distance = up to 2.50 m COLUM EC 2000 2001 2001.5 2002 2002.5 2003 Air quantity max. m3/h 1800 2700 3600 4500 5400 Heating capacity rated1 LPHW 70 / 50 °C kW 8.5 12.7 17.0 21.2 25.5 LPHW 60 / 40 °C kW 8.5 12.7 17.0 21.2 25.5 Flow rate LPHW 70 / 50 °C m3/h 0.37 0.56 0.75 0.93 1.30 LPHW 60 / 40 °C m3/h 0.37 0.55 0.74 0.92 1.29 Water resistance LPHW 70 / 50 °C kPa 0.5 5.7 2.4 3.2 4.1 LPHW 60 / 40 °C kPa 3.8 7.0 4.5 3.2 4.2 Nominal connection Internal thread Inches 2 x 3/4" 2 x 3/4" 2 x 3/4" 2 x 3/4" 2 x 3/4" sizes Flow/return DN 20 20 20 20 20 EC fans Voltage V 230 / 1 / N / PE Frequency Hz 50 Current consumption A 2.1 3.1 4.1 5.1 7.2 Motor power kW 0.3 0.5 0.6 0.8 0.9 Electric heater Voltage V 400 / 3 / N / PE 3-stage Frequency Hz 50 Heating capacity kW 3/6/9 4/8/12 6/12/18 6/12/18 10/20/30 Sound pressure level2 Highest setting dB(A) 58 59 60 61 62 Drawing dimension Unit height/width (A) mm 1000 1500 2000 2500 3000 Diameter mm 400 400 400 400 400 Weight kg 50 70 90 100 134 * WE RESERVE THE RIGHT TO MAKE TECHNICAL CHANGES 1. Rated operation based on operating point (see above), discharge temperature control recommended. 2. Measured at a lateral distance of 3 m. Sound pressure level may very depending on surrounding conditions. A well-balanced pressure ratio is one of the prerequisites for perfect function. 14
COLUM EC 3000 TECHNICAL DATA Design based on: recommended operating point intake temperature tLE = +20 °C discharge temperature tLA = +34 °C discharge height = up to 2.80 m COLUM EC 3000 3001 3001.5 3002 3002.5 3003 Air quantity max. m3/h 2700 3600 5400 6300 7200 Heating capacity rated1 LPHW 70 / 50 °C kW 12.7 17.0 25.5 29.7 34.0 LPHW 60 / 40 °C kW 12.7 17.0 25.5 29.7 34.0 Flow rate LPHW 70 / 50 °C m3/h 0.56 0.75 1.11 1.31 1.49 LPHW 60 / 40 °C m3/h 0.55 0.74 1.11 1.29 1.48 Water resistance LPHW 70 / 50 °C kPa 0.8 2.8 3.7 5.2 7.2 LPHW 60 / 40 °C kPa 1.7 3.7 4.2 6.1 7.2 Nominal connection Internal thread Inches 2 x 3/4" 2 x 3/4" 2 x 3/4" 2 x 3/4" 2 x 3/4" sizes Flow/return DN 20 20 20 20 20 EC fans Voltage V 230 / 1 / N / PE Frequency Hz 50 Current consumption A 3.1 4.1 6.2 7.2 8.2 Motor power kW 0.5 0.6 0.9 1.1 1.2 Electric heater Voltage V 400 / 3 / N / PE 3-stage Frequency Hz 50 Heating capacity kW 5/10/15 7.5/15/22.5 10/20/30 10.7/21.4/32 10.7/21.4/32 Sound pressure level2 Highest setting dB(A) 60 61 62 63 64 Drawing dimension Unit height/width (A) mm 1000 1500 2000 2500 3000 Diameter mm 400 400 400 400 400 Weight kg 62 77 103 135 145 * WE RESERVE THE RIGHT TO MAKE TECHNICAL CHANGES 1. Rated operation based on operating point (see above), discharge temperature control recommended. 2. Measured at a lateral distance of 3 m. Sound pressure level may very depending on surrounding conditions. A well-balanced pressure ratio is one of the prerequisites for perfect function. 15
COLUM EC 4000 TECHNICAL DATA Design based on: recommended operating point intake temperature tLE = +20 °C discharge temperature tLA = +34 °C throw distance = up to 3.20 m COLUM EC 4000 4001 4001.5 4002 4002.5 4003 Air quantity max. m3/h 4500 5100 7300 9800 12000 Heating capacity rated1 LPHW 70 / 50 °C kW 21.2 24.0 34.4 46.2 56.6 LPHW 60 / 40 °C kW 21.2 24.0 34.4 46.2 56.6 Flow rate LPHW 70 / 50 °C m3/h 0.93 1.05 4.51 2.02 2.48 LPHW 60 / 40 °C m3/h 0.92 1.05 1.50 2.01 2.47 Water resistance LPHW 70 / 50 °C kPa 4.5 4.1 9.1 4.4 6.9 LPHW 60 / 40 °C kPa 3.2 4.1 3.7 4.5 7.0 Nominal connection Internal thread Inches 2 x 1" 2 x 1" 2 x 1" 2 x 1" 2 x 1" sizes Flow/return DN 25 25 25 25 25 EC fans Voltage V 230 / 1 / N / PE Frequency Hz 50 Current consumption A 6.0 6.5 9.1 12.1 15.0 Motor power kW 1.1 1.4 2.1 2.7 3.5 Electric heater Voltage V 400 / 3 / N / PE 3-stage Frequency Hz 50 Heating capacity kW On request Sound pressure level2 Highest setting dB(A) 64 64 64 65 67 Drawing dimension Unit height/width (A) mm 1000 1500 2000 2500 3000 Diameter mm 600 600 600 600 600 Weight kg 85 120 160 200 240 * WE RESERVE THE RIGHT TO MAKE TECHNICAL CHANGES 1. Rated operation based on operating point (see above), discharge temperature control recommended. 2. Measured at a lateral distance of 3 m. Sound pressure level may very depending on surrounding conditions. A well-balanced pressure ratio is one of the prerequisites for perfect function. 16
COLUM EC 5000 TECHNICAL DATA Design based on: recommended operating point intake temperature tLE = +20 °C discharge temperature tLA = +34 °C discharge height = up to 3.60 m COLUM EC 5000 5001 5001.5 5002 5002.5 5003 Air quantity max. m3/h 4900 7300 9800 12000 14200 Heating capacity rated1 LPHW 70 / 50 °C kW 23.1 34.4 46.2 56.6 67.0 LPHW 60 / 40 °C kW 23.1 34.4 46.2 56.6 67.0 Flow rate LPHW 70 / 50 °C m3/h 1.01 1.51 2.02 4.48 2.93 LPHW 60 / 40 °C m3/h 1.01 1.50 2.01 4.45 2.92 Water resistance LPHW 70 / 50 °C kPa 1.3 2.9 7.9 7.8 9.6 LPHW 60 / 40 °C kPa 3.8 2.4 4.7 7.8 9.7 Nominal connection Internal thread Inches 2 x 1 1/4" 2 x 1 1/4" 2 x 1 1/4" 2 x 1 1/4" 2 x 1 1/4" sizes Flow/return DN 32 32 32 32 32 EC fans Voltage V 230 / 1 / N / PE Frequency Hz 50 Current consumption A 6.1 9.1 12.1 15.2 18.2 Motor power kW 1.4 2.1 2.8 3.5 4.1 Electric heater Voltage V 400 / 3 / N / PE 3-stage Frequency Hz 50 Heating capacity kW On request Sound pressure level2 Highest setting dB(A) 63 64 65 66 68 Drawing dimension Unit height/width (A) mm 1000 1500 2000 2500 3000 Diameter mm 600 600 600 600 600 Weight kg 120 155 200 235 265 * WE RESERVE THE RIGHT TO MAKE TECHNICAL CHANGES 1. Rated operation based on operating point (see above), discharge temperature control recommended. 2. Measured at a lateral distance of 3 m. Sound pressure level may very depending on surrounding conditions. A well-balanced pressure ratio is one of the prerequisites for perfect function. 17
COLUM 2000 DX-H EC TECHNICAL DATA ONLY HEATING MODE POSSIBLE Design based on: recommended operating point intake temperature tLE = +20 °C discharge temperature tLA = +34 °C throw distance = up to 2.50 m heating gas temperature = 70° C condensation temperature = 50 °C condensate exit temp. = 45 °C operating pressure = max. 45 bar COLUM 2000 DX-H EC 2001 2001.5 2002 2002.5 Air quantity max. m3/h 1800 2700 3600 4500 Power1 DX heating capacity kW 8.1 12.5 16.9 21.3 Delivery and intake line Connections mm 10/16 10/16 10/18 10/22 EC fans3 Voltage V 230 / 1 / N / PE Frequency Hz 50 Max. current consumption A 2.4 3.6 4.7 5.9 Max. motor power kW 0.3 0.5 0.7 0.8 Sound pressure level2 Highest setting dB(A) 58 59 60 61 Drawing dimension Unit height/width (A) mm 1000 1500 2000 2500 Diameter mm 500 500 500 500 Weight kg 50 70 90 100 * WE RESERVE THE RIGHT TO MAKE TECHNICAL CHANGES 1. Rated operation based on operating point (see above). 2. Measured at a lateral distance of 3 m. Sound pressure level may very depending on surrounding conditions. 3. Control voltage 0-10 V. A well-balanced pressure ratio is one of the prerequisites for perfect function. 18
COLUM 3000 DX-H EC TECHNICAL DATA ONLY HEATING MODE POSSIBLE Design based on: recommended operating point intake temperature tLE = +20 °C discharge temperature tLA = +34 °C throw distance = up to 2.80 m heating gas temperature = 70° C condensation temperature = 50 °C condensate exit temp. = 45 °C operating pressure = max. 45 bar COLUM 3000 DX-H EC 3001 3001.5 3002 3002.5 Air quantity max. m3/h 2700 3600 5400 6300 Power1 DX heating capacity kW 12.7 17.0 25.7 29.6 Delivery and intake line Connections mm 10/16 10/18 10/22 10/22 EC fans3 Voltage V 230 / 1 / N / PE Frequency Hz 50 Current consumption A 3.5 4,7 7.1 8.2 Motor power kW 0.5 0.7 1.0 1.2 Sound pressure level2 Highest setting dB(A) 60 61 62 63 Drawing dimension Unit height/width (A) mm 1000 1500 2000 2500 Diameter mm 500 500 500 500 Weight kg 62 77 103 135 * WE RESERVE THE RIGHT TO MAKE TECHNICAL CHANGES 1. Rated operation based on operating point (see above). 2. Measured at a lateral distance of 3 m. Sound pressure level may very depending on surrounding conditions. 3. Control voltage 0-10 V. A well-balanced pressure ratio is one of the prerequisites for perfect function. 19
www.TEKADOOR.de German headquarters TEKADOOR GmbH Albert-Einstein-Str. 11 D-40764 Langenfeld T. +49 (0) 2173 - 20766-0 F. +49 (0) 2173 - 20766-111 E. info@tekadoor.de A = 01.07.2019