2        Case Study    Canberra MRT Station                     Canberra MRT Station       Case Study   3

The Project
The Canberra station (NS12) is an elevated Mass Rapid
Transit (MRT) station on the North South Line located
along Canberra Link in Sembawang, Singapore. The
station will be linked to Canberra Plaza via an elevated
sheltered footbridge built across Canberra Link. It
is estimated that approximately 17,000 households
will benefit from the station due to the upcoming                                  Aesthetics
Housing and Development Board (HDB) public housing
developments, private condominiums as well as landed
properties (Sembawang Springs Estate) located near the
station. RSP Architects approached Kingspan to design
and develop an aesthetic and functional roof system for
the station.

Sector                Public Transport and Infrastructure

Location              Singapore

Client                Land Transport Authority (LTA)

Architects            RSP Architects, Singapore

Main Contractor       China State Construction Engineering
                      Corporation (Singapore)

Product and System    KingZip Linea 400 1.2mm thk
                      Aluminium, 2 coat PVDF painted,
                      precurved sheets: 8,000m2
                      Kingspan WA200 Structural Liner with in
                      0.47mm thick GI steel: 8,000m2
Canberra MRT Station, Sembawang, Singapore Case Study
Canberra MRT Station   5

The Design                                                                                                                       “KingZip Linea with its 65mm tall ribs and
                                                                                                                                 manufactured from Aluminium Alloy Grade 3004
                                                                                                                                 is certified for use down to a 1.5 degree incline had
The Architect’s design brief and specifications required the roof covering to be in a single length sheet, without end laps.
                                                                                                                                 adequate flexibility to achieve the required curvatures
Thermal transmittance values and acoustic performance of the roof relating to airborne sound transmission and rain impact
were also stipulated. The project specification required Thermal Transmittance Value (U value) no higher than 0.5W/m2K and
                                                                                                                                 of the barrel vault roof design of the project.“
a Sound Transmission Class (STC) of at least 38dB. Kingspan was able to exceed both these requirements with our proposed         Chong Park Cheong
roof build-up. In addition to the acoustic and thermal performance requirements, as the structure being a public transport       General Manager - South East Asia
facility, the lining material had to meet Class O of the Building Standards, and must pass BS476 Part 6 & 7. The KingZip Linea
                                                                                                                                 Kingspan Insulated Panels
roof layer and the steel decking layer meet these requirements exactly and is also accredited Class 1 Roof Panel as per FM
Approvals Standard FM4471.

                                                                             Build Ease                                                              Fire
Canberra MRT Station, Sembawang, Singapore Case Study
6        Case Study            Canberra MRT Station                                                                              Canberra MRT Station   Case Study   7

The Construction
Due to the fact that the station was being built on a live and operational track, LTA and SMRT implemented several measures
to improve safety such as limiting major works to non-service hours, sheltering the tracks with a temporary enclosure during
the construction of the roof and creating a full-scale mock-up of the station structure and roof to determine the safest
process of construction. In order to meet the safety requirements, the production of KingZip Linea Aluminium Standing Seam
roofing was carried out on-site after service hours of the live MRT track. Kingspan portable rollfromers and curving equipment
were fitted into shipping containers and mounted on a Kingspan trailer which allowed onsite manufacturing and smooth
curving of KingZip to the required radii. Manufactured KingZip Linea sheets were hoisted to the roof at early hours of the
morning and late evenings. This process eliminated the logistical burden of transporting 45 tons of aluminium roofing sheets
to the site by long trailers.
Canberra MRT Station, Sembawang, Singapore Case Study
Contact details

Middle East, Africa,                                               Americas                                Australia
Turkey & Central Asia
                                                                   Morin Corporation                       Kingspan Insulated Panels Australia
Kingspan Insulated Panels                                          685 Middle Street | Bristol CT          38-52 Dunheved Circuit
Manufacturing LLC                                                  06010 | U.S.A.                          St Marys | NSW 2760
PO Box 60493
Dubai Investment Park Gate 1                                       T: +1 (860) 584-0900                    T: +61 (02) 8889 3000
Dubai l UAE                                                        E: kingzip@kingspan.com                 E: info@kingspanpanels.com.au
                                                                   www.kingspanpanels.com                  www.kingspanpanels.com.au
T: +971 4 8854232
E: info@kingspanpanels.ae
www.kingspanpanels.ae
                                                                   South East Asia                         India
                                                                   Kingspan Insulated Panels Pty Limited   Kingspan Jindal Pvt. Ltd.
UK & Europe                                                        1 Commonwealth Lane #07-26              Old Manesar Road | Narsinghpur
                                                                   Singapore 149544                        Gurgaon - 122001 | Haryana | India
Kingspan Limited
Greenfield Business Park 2                                         T: +65 6264 5942                        T: +91 124 4393 200
Bagillt Road | Holywell                                            E: infosea@kingspan.com                 E: sales@kingspanjindal.com
CH8 7GJ | UK                                                       www.kingspanpanels.sg                   www.kingspanjindal.com

T: +44 (0) 1352 716 100
E: kingzip@kingspan.com
www.kingspanpanels.co.uk

  For the product offering in other markets please contact your local sales representative
  or visit www.kingspanpanels.com

  Care has been taken to ensure that the contents of this publication are accurate, but
  Kingspan Limited and its subsidiary companies do not accept responsibility for errors
  or for information that is found to be misleading. Suggestions for, or description of, the
  end use or application of products or methods of working are for information only and
  Kingspan Limited and its subsidiaries accept no liability in respect thereof.

  07/2020
Canberra MRT Station, Sembawang, Singapore Case Study
You can also read