Chemical Analysis Biodiesel Analyzers A family of Comprehensive Solutions Gas Chromatography think forward
Bruker GC Biodiesel Analyzers Biodiesel is one of the most promising alternative fuel sources available today. Unlike conventional diesel fuel derived from crude oil, biodiesel comes from vegetable oils and animal fats. Compared to its fossil fuel based counterpart, biodiesel is safe, renewable, biodegradable, cleaner burning and is compatible with today’s diesel engines. However, like its petroleum based counterpart, biodiesel can present a significant analysis challenge. Extremely powerful, easy to use A broad range of application optimized analysis solutions. Bruker’s flexible consumables columns specifically 450-GC or single channel 430-GC designed for biodiesel analysis and GalaxieTM Chromatography Data and long life time. All consumables Handling Software, combined with included in these biodiesel analysis a broad range of application optimized solutions have been carefully selected columns and comsumables provides to ensure both high performance and the analytical power needed to reliability. Furthermore, a range of perform all biodiesel analysis methods high performance capillary columns and ensures that conducting them is has been developed specifically for simple and straightforward. biodiesel applications, including the SelectTM Biodiesel Glycerides A complete range of GC based metal column which provides superior biodiesel solutions. Bruker offers separation performance, extremely low comprehensive solutions for phase bleed performance and the analysis of biodiesel by gas unequalled column lifetime. chromatography based on ‘standard’ methods. These include: EN-14105 Single vendor analysis solutions. (free and total glycerol, mono, di and Bruker is proud of its ability to provide tri-glycerides content), EN-14103 (total a complete solution. All hardware, FAME and linolenic acid methyl software, application optimization, esters), EN14106 (free glycerol), documentation, installation and EN-14110 (residual methanol) and performance verification are provided ASTM D6584 (free and total glycerin). and supported by Bruker, or a trained and authorized Bruker dealer. Outstanding multi-channel flexibility of the 450-GC. Depending on your analysis and throughput requirements, two or more standard methods can be acommodated with a single 450-GC system. Both an automated liquid and headspace sampler can be installed on a single 450-GC. It is therefore possible to conduct more than one standard GC analysis The 450-GC and GalaxieTM method, on a single system chromatography workstation without the need for any hardware team to provide a powerful reconfiguration or lengthy start up/ analysis platform for biodiesel equilibration times. analysis by GC.
Key Benefits Standard Method Analytes Injector Type Recom- mended GC Time per Analysis ASTM Free & total On- 450-GC 32 mins D 6584 Glycerine Column EN-14103 Ester & linoleic Split / 450-GC or 30 mins acid methl esters Splitless 430-GC EN-14105 Free and total On- 450-GC 35 mins Glycerine & Mono, Column Introduction Di & Tri-glycerides There are a variety of ways to determine EN-14106 Free Glycerol Split / 450-GC or 10 mins Splitless 430-GC biodiesel composition and quality. Both ASTM (American Standard and Testing EN-14110 Methanol Headspace 450-GC or 10 mins with Split / 430-GC Methods) and CEN (Comite Europeen Splitless de Normalisation) have implemented methods to characterize biodiesel and ensure it conforms to their standard specifications: EN-14214 or ASTM with these particular methods is D6751. Of all biodiesel standard methods stress placed on the capillary column in use today, those employing GC are the as it is subjected to repetitive high most commonly used. These methods temperature thermal cycling of the are listed and summerized: oven. If conventional fused silica capillary columns are used for either Analysis of Free Glycerine and Total of these methods, a severe reduction Glycerol; EN-14105, ASTM D6584 in useful column lifetime results. This The analysis of glycerine in biodiesel is is due to structural failure of the fused extremely important because excessive silica column coating itself leading to amounts can make long term storage ‘shattering’. To combat this problem, problematic, or cause the formation of Bruker is using a new specifically unwanted deposits, leading to injector designed capillary column (SelectTM fouling and accelerated engine wear. Biodiesel). The column is constructed of The analysis of free glycerine and total high tensile strength metal, eliminating glycerol requires the use of on-column the possibility of column failiure. injection with a high resolution capillary Furthermore, the column is extremely column operated at a very high easy to install because it has the temperature (>350 °C). retention gap pre-coupled and thoroughly Although there are several factors which leak tested at the factory. can negatively impact the performance of a GC, the most significant associated Methanol Quality Methyl Purification Catalyst Recovery Control Ester Catalyst Mixing Methanol Pharmaceutical Grade Glycerine Recycled Methanol Vegetable Oil, Crude Cooking Oils, Transesterification Glycerine Biodiesel Animal Fats Purification Neutralizing Neutraliza- Phase Reneutra- Methanol Crude Acid tion Separation lization Recovery Glycerine
Bruker GC Biodiesel 1150000.0 400 C 18:0 C 18:1 C 18:2 C 16:0 350 Analyzers 1050000.0 300 C 20:0 C 20:1 950000.0 250 850000.0 200 C 24:0 C 24:1 Select Biodiesel ‘Glycerides’ column TM 4 C 22:0 C 22:1 750000.0 150 for robust, superior performance 650000.0 3 The structural integrity of the column at 2 100 very high temperatures is not the only 550000.0 1 3 3 5 6 50 measure of operational robustness. The column must also provide reproducible 450000.0 0.0 5.0 10.0 15.0 20.0 25.0 30.0 0 35.0 Time (min) results (see Figure 1). Select Biodiesel Glycerides columns have been specially Chromatogram of B-100 biodiesel obtained via EN-14105 method. decactivated using a proprietary process, and coated with an ultra stable stationary phase. They are optimized specifically 0.044 for the analysis of the glycerol and 0.043 0.042 Glycerol Avg. 0.0394 % (m/m) RSD 0.070 % glycerides content of biodiesel according 0.041 0.040 % (m/m) 0.039 to ASTM D6584 (15 M column) and 0.038 0.037 EN-14105 (10 M column length). 0.036 0.035 Figure 1 shows the results of a study 0.950 0.900 where the bleed of the Select Biodiesel 0.850 Monoglycerides Avg. 0.790 % (m/m) RSD 0.65 % Glycerides column was compared to an % (m/m) 0.800 0.750 available ‘high performance/low bleed’ 0.700 fused silica capillary column. It is also 0.650 important to note that due to thermal 0.170 0.165 Diglycerides cycling in the GC oven, the coating on 0.160 Avg. 0.155 % (m/m) RSD 1.58 % % (m/m) the fused silica column deteriorated after 0.155 0.150 52 hours, leading to catastrophic failiure, 0.145 while the Select column was producing 0.140 consistent high performance after nearly 0.640 0.590 Triglycerides 700 hours of continuous operation. Avg. 0.520 % (m/m) RSD 0.86 % % (m/m) 0.540 0.490 0.440 0.390 1 2 3 4 5 6 7 8 9 10 11 12 13 Injection Number Typical repeatability results of 13 sequential injections of a spiked B-100 biodiesel sample, using the Select Biodiesel Glycerides column. Red lines represent the maximum allowed variation per standard method EN-14105. 30,0 Bleedlevel [pA] 25,0 Bleedlevel 20,0 [pA] Fused silica column disintegrated after 15,0 52 hrs at 400°C 10,0 Biodiesel for Glycerides column (Ultimetal) at 400°C: 5,0 very stable and reliable (n=3) Phase bleed comparison between Select 0,0 0 100 200 300 400 500 600 700 Biodiesel Glycerides column and conventional Time @ 400°C [hrs] ‘ultra low bleed’ fused silica column.
C17:0 C18:1 Bruker GC Biodiesel C16:0 C18:0 C18:2 C18:3 Analyzers C20:1 C20:0 C14:0 C22:0 C22:1 C24 isomers 0 5 10 15 20 25 Min. 30 450-GC with with automated headspace sampler for the analysis of Chromatogram of B-100 biodiesel using SelectTM Biodiesel for methanol via EN 14110. FAME column according to EN-14103. Description ASTM D 6584 EN-14103 EN-14105 EN-14106 EN-14110 Free and total Ester and Free and total glyc- Free Glycerol Methanol glycerine Linoleic acid erine and Mono, Di methyl esters and Tri-glycerides GC Columns Select™ Biodiesel for Glycerides UltiMetal™, 15 m x 0.32 mm x 0.1 µm + 2 m x 0.53 mm ID CP9078 retention gap Select™ Biodiesel for Glycerides UltiMetal™, 15 m x 0.32 mm x 0.1 µm CP9079 Select™ Biodiesel for Glycerides UltiMetal™, 10 m x 0.32 mm x 0.1µm + 2 m x 0.53 mm ID CP9076 retention gap Select™ Biodiesel for Glycerides UltiMetal™, 10 m x 0.32 mm x 0.1µm CP9077 Select™ Biodiesel for FAME Fused Silica, 30 m x 0.32 mm x 0.25 µm CP9080 Select™ Biodiesel for Methanol Fused Silica, 30 m x 0.32 mm x 3.0 µm CP9083 CP-PoraPLOT® Q, 10 m x 0.32 mm x 10 µm CP7550 UltiMetal Column Accessories UltiMetal™ retention gap methyl deactivated, 2 m x 0.53 mm ID CP6530 CP6530 UltiMetal™ tube cutter CP8099 CP8099 Replacement blade for UltiMetal™ tube cutter CP736832 CP736832 End straightener for UltiMetal™ tubing CP8098 CP8098 Column Connectors for Retention Gap / Pre-column High temperature column connector ID = 0.5 mm CP4795 CP4795 Ferrules for HT column connector graphite for tube size = 0.5 mm OD (0.32 mm ID) 10 st CP4733 CP4733 Ferrules for HT column connector graphite for tube size = 0.8 mm OD (0.53 mm ID) CP4734 CP4734 Siltite ferrules for GC Injector / Detector 0.32 mm ID SG073301 SG073301 Siltite ferrules for GC Injector / Detector 0.53 mm ID SG073302 SG073302 Other Column Accessories Tungsten carbide glass knife CP22674 CP22674 CP22674 Column cage support 393305701 393305701 393305701 393305701 393305701 Filters and Gas Management Helium leak detector (American version 110 V) CP87610 CP87610 CP87610 CP87610 CP87610 Helium leak detector (British version 240 V) CP83610 CP83610 CP83610 CP83610 CP83610 Helium leak detector (European version 230 V) CP80610 CP80610 CP80610 CP80610 CP80610 Connecting unit for 2 filters 1 / 8 in. CP738407 CP738407 CP738407 CP738407 CP738407 Connecting unit for 4 filters 1 / 8 in. CP736520 CP736520 CP736520 CP736520 CP736520 Gas Clean Oxygen Filter CP17970 CP17970 CP17970 CP17970 CP17970 Gas Clean Moisture Filter CP17971 CP17971 CP17971 CP17971 CP17971 Gas Clean Charcoal Filter CP17972 CP17972 CP17972 CP17972 CP17972 Injector / Detector Accessories Graphite ferrule for FID burner tip (10 / pk) CR211200 CR211200 BTO Septa (50 / pk) CR298777 CR298777 CR298777 CR298777 CR298777 Metal capillary nut for use with Bruker GCs CP959468 394955100 CP959468 394955100 394955100 Recommended columns and consumables for biodiesel analysis.
Chemical Analysis Solutions GC quadrupole mass spectrometers The Bruker 300-MS series GC/MS systems stand at the pinnacle of versatility for quadrupole mass spectrometer systems. Both the 300-MS and 320-MS are configurable as either single-quadrupole, or triple-quadrupole systems. The 300-MS delivers the performance you‘ve come to expect from an industry leader in quadrupole innovation. It features an 800 Da mass range, superior negative ion sensitivity, and unmatched robustness in its performance class. The 320-MS delivers femtogram sensitivity, 2000 Da mass range, and a wide array of chromatographic and ionization configurations to uniquely match your needs - all in less than 72 cm. (28 in.) of linear bench space! In minutes, our 300-MS series systems can be changed from EI to CI modes of operation. Easily, our 300-MS and 320-MS are the most sensitive, robust, and flexible quadrupole GC/MS systems currently available. ICP mass spectrometers Choosing an ICP-MS for your elemental analysis needs has never been easier with the Bruker 800-MS Series. The 810-MS is the instrument of choice for routine analysis with industry leading sensitivity and intuitive Web-integrated ICP-MS Expert software. The 820-MS features Bruker‘s novel collision reaction interface (CRI), providing interference-free analysis and allowing you to tackle any application with ease. With a vast Bruker Daltonics is continually improving its products and reserves the right range of accessories, Bruker has the solution to to change specifications without notice. © BDAL 06-2010, #CA-270352 all your ICP-MS application requirements. For research use only. Not for use in diagnostic procedures. Bruker Daltonik GmbH Bruker Daltonics Inc. Bremen · Germany Billerica, MA · USA Phone +49 (421) 2205-0 Phone +1 (978) 663-3660 Fax +49 (421) 2205-103 Fax +1 (978) 667-5993 sales@bdal.de ms-sales@bdal.com www.bruker.com/chemicalanalysis