BI-FOLDING DOORS ECOLINE | HIGHLINE - Ecohaus Internorm

Page created by Ernest Wolfe
 
CONTINUE READING
BI-FOLDING DOORS ECOLINE | HIGHLINE - Ecohaus Internorm
BI-FOLDING DOORS
ECOLINE | HIGHLINE
BI-FOLDING DOORS ECOLINE | HIGHLINE - Ecohaus Internorm
BI-FOLDING DOORS
ECOLINE | HIGHLINE

RUNNER ASSEMBLY
··Stainless steel runner assembly with
double-row deep-groove ball bearings
··Ease of operation, smooth running and quiet
··Optimum load transfer
··Wear-free and extremely low maintenance

                                                LOCKING
                                                ··RC2 burglar protection
                                                optional
                                                ··24 mm espagnolette throw
                                                at top and bottom of frame
                                                ··Optional linking to
                                                security system
                                                ··Concealed cable routing

                                                "COMFORT SNAP" PANEL
                                                CATCHES
                                                ··Maximum user-friendliness
                                                for correct locking sequence
                                                ··Catch function allows
                                                controlled opening and
                                                closing of the panels
SOLARLUX BI-FOLDING DOORS      ECOLINE | HIGHLINE

"EASY CLEAN"                                         3S TRACK GUARD
REMOVABLE HINGE PIN                                  ··High quality clip-on
··Easy cleaning even with high                       aluminium track guard
floor-to-ceiling dimensions                          ··Well-designed locking
··New integral locking tech-                         channel cover
nology with error device                             ··Additionally protects
··Captive hinge pin which                            from ingress of dirt
cannot drop out accidentally

ADJUSTMENT PROFILE                                   FRAME COVER
··Simple adjustment for                              ··Tasteful, flush cover of
panel tolerances                                     subframe fixing screw heads
··Adjustment of panels                               ··Concealed cable routing
from one single profile                              between bottom of profile
··No break to seal                                   and cover possible

                                                     "TWINX" CONCEALED PANEL
                                                     CENTRING MECHANISM
                                                     ··Elegant slimline panel design
                                                     throughout with even joints
                                                     ··No break to sealing face
                                                     ··Constant sealing pressure
BI-FOLDING DOORS
ECOLINE | HIGHLINE

                     The centre piece of the
                99
                     bi-folding door system

                     The new bi-folding door system is     bionicTURTLE®, a multi-functio-
                     available in two versions: Ecoline    nal thermal-break which combines
                     and Highline. Despite their differ-   various design aspects. The design
                     ence in unit thicknesses of 67 and    of this profile form provides the
                     84 mm, the new bi-folding system      basis for the stability of the slen-
                     with its 99 mm sight line offers an   der upright profiles. In addition,
                     unusual elegant slender appear-       it accommodates provisions for
                     ance throughout. What makes this      locking mechanism as well as door
                     possible is its centre piece: the     furniture and guarantees perfect

Configuration
Examples
SOLARLUX BI-FOLDING DOORS   ECOLINE | HIGHLINE

Floor Track Versions

                                                                        *

··floor track suitable for living accommodation     ··recessed floor track
··with upstand                                      ··without upstand for wheelchair access
                                                     outwards opening
                                  inwards opening

··floor track suitable for living accommodation     ··floor track suitable for living accommodation
··for wheelchair access with 14 mm upstand          ··for wheelchair access with 14 mm upstand

     *                                                                  *

··mini floor track (29 mm wide)                     ··mini floor track (29 mm wide)
··for wheelchair access with 14 mm upstand          ··for wheelchair access with level threshold
BI-FOLDING DOORS
ECOLINE | HIGHLINE
System Features

PROFILE SYSTEM                                                     outside sealing face
··Highly thermally insulated modular aluminium profile             ··Optimised design of the stainless steel runner track together
system available in two unit thicknesses:                          with the hourglass-shaped runners allow for an unguided
··67 mm Ecoline and 84 mm Highline                                 runner assembly
··Floor mounted. Therefore little load bearing capacity            ··Quiet runner mechanisms with extremely long life stainless
of lintel required                                                 steel ball bearings and bearing surfaces
··Angular profile design                                           ··Easy, smooth and wear-resistant runner assemblies with
··Minimum sight lines of 99 mm at the panel joints                 double row deep groove ball bearings and integrated
··"bionicTURTLE®", a GFR Polyamid single piece,                    anti-prying guard
multi-functional thermal break profile                             ··High-grade stainless steel Solarlux designer handles
··Loose shear bond in insuling web compensating                    ··Lockable one-hand-operation by means of special
for thermal loads                                                  gearing with 24 mm throw
··Controlled drainage                                              ··Entry/exit panel can be supplied with lever-handle-operated
··Runner and guide tracks integrated into the system               multi-point locking system and profile cylinder lock
··Separate levels for runners and locking                          ··Captive hinge pins
··Floor tracks (for wheelchair access and living                   ··"Easy Clean" removable hinge pins with convenient release
accommodation) available                                           mechanism and operating error prevention device for
··Concealed cable routing can be integrated                        cleaning the outside of panels which open to the inside
                                                                   of folding glass door units.
SEALING SYSTEM                                                     ··Specific locking points at spaced intervals allow the use of
··Sealing by two wrap-around lines of defence with constant        the removable hinge pin on paired as well as non-paried
gap size and even sealing pressure between panels                  folding glass doors
··Sealing faces are not broken by door furniture                   ··Lock monitoring by means of Reed contacts and
··Skinned foam seals with excellent sliding properties             concealed cabling
··Air infiltration barrier seal for enhanced U values as option    ··Patented "Comfort Snap" panel catches with specified
··Up to three lines of defence against ingress possible            locking sequence
                                                                   ··Installation of the subframe profiles and the floor track
CONFIGURATION OPTIONS                                              on load-transferring plates with centering grooves and
··Panels are inward or outward folding and can be designed         sealing cushions is optional
to slide to the right or left                                      ··Additional covering of the fixing screws in the frame rebate
··Floor tracks without upstand to DIN 18040
(for wheelchair access)                                            ENVIRONMENT
··For level thresholds, mini floor tracks are possible             ··Sustainable manufacturing
··RC2-/RC2N burglar protection optional                            ··Certified waste disposal to DIN EN ISO 14001: 2009
··If folding panel pair is hinged on frame side, tilt and turn
panels can be integrated with concealed door                       MANUFACTURING FACILITY
··Folding, tilting, tilt and turn or fixed units can be combined   ··Internal production inspection
in one single frame with continuous floor track by means of        ··Tested to DIN EN 1090 execution class EXEC1 and EXEC2
an integrating profile and modular design.                         ··Certified to DIN EN ISO 9001
··Single frame installation for mounting of folding system
on parapet even with transom windows now

DOOR FURNITURE
··No protruding runner and guide tracks
··Concealed door furniture for one-handed operation
··For increased wind loads additional concealed panel centring
facility "TwinX" can be integrated
··System hinges for increased panel weights available
··Integrated system adjustment in subframe rebate

*applies only to Highline
SOLARLUX BI-FOLDING DOORS                                            ECOLINE | HIGHLINE

Ecoline Features                                                                                                     Highline Features

                                Resistance to wind load                                                                                                Resistance to wind load
                                                                                                   B4                                                                                                                   B4
                                to DIN EN 12210                                                                                                        to DIN EN 12210

                                Protection against driving rain                                                                                        Protection against driving rain to
                                                                                                   8A                                                                                                                   9A
                                to DIN EN 12208                                                                                                        DIN en12208

                                Air permeability                                                                                                       Air permeability
                                                                                                    3                                                                                                                    3
                                to DIN EN 12207                                                                                                        to DIN EN 12207

                                Mechanical durability                                                                                                  Mechanical durability
                                                                                                    2                                                                                                                    2
                                to DIN EN 1191/12400                                                                                                   to DIN EN 1191/12400

                                Burglar resistance                                               RC2/                                                  Burglar resistance                                             RC2/
                                to DIN EN 1627-1630                                              RC2N                                                  to DIN EN 1627-1630                                            RC2N

                                Sound insulation class                                          R´w up                                                 Sound insulation class                                        R´w up
                                to DIN EN ISO 140-1                                            to 40 dB                                                to DIN EN ISO 140-1                                          to 45 dB

                                Thermal performance of                                                                                                 Thermal performance of
                                                                                                Uw ≥ 1,1                                                                                                            Uw ≥ 0,8
                                windows, doors and shutters                                                                                            windows, doors and shutters
                                                                                                W/m2K                                                                                                                W/m2K
                                to DIN EN ISO 10077-1                                                                                                  to DIN EN ISO 10077-1

Note: Details depend on version and glass                                                                            Note: Details depend on version and glass

Ecoline Panel Sizes                                                                                                  Highline Panel Sizes
          panel width (mm)                                                                                                        panel width (mm)
 3600                                                                                                                3600

 3500
                                                                         applies to infill panels / glass of up to   3500
                                                                                                                                                                                              applies to infill panels / glass of up to
                                                                         25 kg/m2                                                                                                             25 kg/m2
 3400                                                                                                                3400

 3300                                                                                                                3300
                                                                         applies to infill panels / glass of up to                                                                            applies to infill panels / glass of up to
 3200
                                                                         35 kg/m2                                    3200
                                                                                                                                                                                              35 kg/m2

 3100                                                                                                                3100

                                                                         applies to infill panels / glass of up to                                                                            applies to infill panels / glass of up to
 3000                                                                                                                3000
                                                                         45 kg/m2                                                                                                             45 kg/m2
 2900                                                                                                                2900

 2800                                                                                                                2800

 2700                                                                                                                2700

 2600                                                                                                                2600

 2500                                                                    VISIBLE PROFILE THICKNESSES                 2500                                                                     VISIBLE PROFILE THICKNESSES
                                                                         ·· frame 0 – 72 mm                                                                                                   ·· frame0 – 72 mm
 2400                                                                                                                2400
                                                                         ·· panel 66 mm                                                                                                       ·· panel 66 mm
 2300                                                                    ·· panel joint 99 mm                        2300                                                                     ·· panel joint 99 mm
                                                     panel height (mm)

                                                                                                                                                                          panel height (mm)

                                                                         ·· frame thickness 67 mm                                                                                             ·· frame thickness 84 mm
 2200                                                                                                                2200
                                                                         ·· panel thickness67 mm                                                                                              ·· panel thickness84 mm
 2100                                                                    ·· mini floor track29 mm                    2100
                                                                                                                                                                                              ·· mini floor track29 mm

 2000                                                                                                                2000
                                                                         GLAZING                                                                                                              GLAZING
 1000                                                                    ·· glass thicknesses of                     1000
                                                                                                                                                                                              ·· glass thicknesses of
        600   700   800   900   1000   1100   1200                       5 – 36 mm can be used                              600    700   800   900   1000   1100   1200                       22 – 60 mm can be used
                                                                         ·· dry glazing                                                                                                       ·· dry glazing

Note:
                                                                                                                     Note:
·· Dimensions include frame portion
                                                                                                                     ·· Dimensions include frame portion
·· Recommend horizontal division bars for system heights ≥ 2550 mm
                                                                                                                     ·· Recommend horizontal division bars for system heights ≥ 2550 mm
·· Max. panel weight 90 kg
                                                                                                                     ·· Max. panel weight 110 kg
·· Min. panel width 700 mm for paired versions
                                                                                                                     ·· Min. panel width 900 mm for paired versions
·· Max. installation height for systems with opening panel 2700 mm
                                                                                                                     ·· Max. installation height for systems with opening panel 2700 mm
·· Wind and impact loads may limit the panel size
                                                                                                                     ·· Wind and impact loads may limit the panel size
·· Special sizes on request
                                                                                                                     ·· Special sizes on request
56-702-1223-900 / 04.2017 / Subject to technical alterations

                                                 geprüft & zertifiziert

                                                         91040001      NT
                                                 IISSOO

                                                                    ME
                                                        NA
                                                                 GE
                 PEFC/04-31-1592                            MA
                                                    LT

solarlux.com
                                                       WE

                                                              2 0104
                                                    UM
                                                                 0501

                                       
                                                            ISO
               Promoting Sustainable
                Forest Management
                                                 QUALITÄTSMANAGEMENT
                   www.pefc.org
                                             UMWELTMANAGEMENT
You can also read