WICLINE 115 AFS Composite window system - Venetian blinds 03.2019 Instructions for use and maintenance - wictip

Page created by Laurie Reyes
 
CONTINUE READING
WICLINE 115 AFS
Composite window system

Venetian blinds 03.2019
Instructions for use and maintenance
Die in dieser Dokumentation enthaltenen Daten und             The data and instructions contained in this documenta-
Hinweise entsprechen den uns bekannten Informa-               tion correspond to the information known to us at the
tionen zum Zeitpunkt der Drucklegung. Eine Haftung            time of printing. There is no liability on our part for the
für die hier enthaltenen Informationen ist ausgeschlos-       information contained herein, unless the errors are de-
sen, es sei denn, die Fehler beruhen auf Vorsatz oder         liberate on our part or attributable to gross negligence
grober Fahrlässigkeit seitens unseres Unternehmens.           by our company.

Die in den Unterlagen dargestellten und beschrie-             The products and applications shown and de-
benen Produkte und Anwendungen sind für Fachun-               scribed in these documents are designed for spe-
ternehmen ausgelegt. Sämtliche Beschreibungen                 cialist companies. All descriptions are provided as
erfolgen als Serviceleistung ohne Anerkennung                 a service, without admitting legal responsibility, and
von Rechtspflichten und entbinden nicht von ei-               do not release the user from the need to check that
gener Prüfung bei der Verwendung für Zwecke                   a product or application is suitable for the particu-
des Anwenders. Branchenübliche Fachkenntnisse                 lar purpose envisaged. Specialist knowledge cus-
sowie Kenntnis des aktuellen gültigen Standes der             tomary in this branch of business and awareness
Technik, werden als bekannt vorausgesetzt und da-             of the latest technology are assumed and conse-
her nicht gesondert beschrieben oder erläutert.               quently are not separately described or explained.

Die Benutzung des Markenzeichens WICONA® ist nur              Use of the trademark WICONA® is permitted only
zulässig, sofern ausschließlich die in den jeweils gültigen   if the structural parts included in the applicable
WICONA-Profilprogrammen aufgenommenen Konstruk-               WICONA profile programmes (profiles, accessories
tionsteile (Profile, Zubehöre und Beschläge) verwendet        and fittings) are exclusively used. The genuineness of
werden. Die Echtheit der Artikel bzw. Teile und die Einheit   the items or parts and the uniformity of the design is
der Konstruktion ist erkennbar durch die entsprechende        identifiable by the corresponding markings on these
Kennzeichnung bei diesen Teilen. Von Hydro Building           parts. WICONA systems developed and tested by
Systems Germany entwickelte und geprüfte WICONA-              Hydro Building Systems Germany for facades, windows
Systeme für Fassaden, Fenster und Türen erhalten mit          and doors are ultimately qualified by the appropriate
entsprechenden Prüfungen und Prüfzeugnissen durch an-         tests and test certificates from recognised institutes.
erkannte Institute ihre endgültige Bestätigung. Für jeden     Each processing company is subject to these test cer-
verarbeitenden Fachbetrieb sind diese Prüfzeugnisse und       tificates and documentation as mandatory work guide-
Dokumentationen verpflichtende Arbeitsrichtlinien. Bei        line specifications. Hydro Building Systems Germany is
festgestellten Mängeln, die an WICONA-Fassaden, -Fen-         not liable for any defects visible on WICONA facades,
stern und -Türen sichtbar werden, weil systemfremde Teile     windows and doors and attributable to the use of parts
verwendet wurden, wird in diesen Fällen jede Haftung          not belonging to the system. The corresponding test
durch Hydro Building Systems Germany ausgeschlossen.          certificates also lose their validity for these items.
Des Weiteren verlieren die attestierten Prüfzeugnisse für     Please also note the ”Important indications“ in the
diese Elemente ihre Gültigkeit.                               opening sections of our profile programmes and pro-
Bitte beachten Sie auch die „Wichtigen Hinweise“ im           cessing guideline specifications.
Vorspann unserer Profilprogramme und Verarbeitungs-           All our sales are subject to these standard terms of
richtlinien.                                                  sale and to any particular and specific conditions
Alle unsere Verkäufe unterliegen diesen allgemeinen           mentioned in our price lists in force and invoices.
Verkaufsbedingungen und allen besonderen und
spezifischen Bedingungen, die in unseren gültigen
Preislisten und Rechnungen aufgeführt sind.

Hydro Building Systems Germany GmbH                           Hydro Building Systems Germany GmbH

® = eingetragene Marke der                                   ® = registered trademark of
    Hydro Building Systems Germany GmbH                          Hydro Building Systems Germany GmbH
WICLINE 115 AFS                                                          Technical Information
Integral sun blind
Operation and maintenance instructions

                                                                                          [int]

           Operation and maintenance instruction

                                             These instructions must be read
                                             before operation and assembly!

 Composite window Venetian
 blind VB 25 mm

      Operating instructions
      Assembly instructions

WICONA® doc-0001149850_c        12.03.2019
                                                     1
2
WICLINE 115 AFS                                                    Technical Information
Integral sun blind
Operation and maintenance instructions

                                                                                    [int]

Content
Page
          Operation and maintenance instructions
              Preliminary remarks Composite window Venetian blind VB 25 mm                 5
              General instructions                                                         6
              CE marking                                                                   7
              Safety instructions                                                          8
              Intended use                                                             12
              Care, maintenance and repair                                             13
              Care, maintenance and repair                                             14
              Operating instructions                                                   15
              Before the installation                                                  16
              Installation in the composite window                                     17
              Electrical connection                                                    18
              Wiring diagram                                                           19
              Test adjustment device for composite window Venetian blinds              21
              Dimensions for ordering Venetian blinds VB 25                            24
              Enquiry and order form for WICONA composite window Venetian blind        25
              Transport recommendation                                                 26
              Control guidelines for electrical systems                                28
              Control guidelines for blind motors                                      29
              Commissioning / functional check                                         30
              Dismantling in general                                                   31
              Handover protocol (for the installer)                                    32
              Handover protocol (for the user)                                         33
          Non-fault catalogue composite Venetian blind VB 25
           1. Standards and guidelines                                                 36
              1.1 Composite window Venetian blinds                                     37
              1.2 Width-height ratio indoor Venetian blind                             38
           2. Surface treatment                                                        39
              2.1 Anodizing                                                            39
              2.2 Powder coating                                                       41
              2.3 Filiform corrosion                                                   44
           3. Test                                                                     45

WICONA® doc-0001149850_c        12.03.2019
                                                     3
4
WICLINE 115 AFS                                                            Technical Information
Integral sun blind
Operation and maintenance instructions

                                                                                                  [int]

Preliminary remarks Composite window
Venetian blind VB 25 mm
By aquiring this WICONA product, you have opted for a top quality product with the most up-to-
date technology, though simple to assemble and to operate. In this manual, we describe the basic
assembly, commissioning and the operation.

• For authorized professional staff

• For the customer (enduser)

The following symbols will support you during assembly or operation and remind you to carry out
safely all the tasks:

            C
             aution!
            This symbol indicates hints which, if not followed, will possibly endanger the user

            Caution!
            This symbol indicates hints which, if not followed, will possibly cause damages to the
            product.

           This symbol indicates application hints or useful information

           This symbol prompts you to an activity.

           C
            aution!
           This symbol indicates risks of injuries or death caused by electrocution.

           T
            his symbol indicates areas on the product to which you will find important information in
           these assembly instructions.

            T
             his symbol indicates the cleaning of the product.

            This symbol indicates the maintenance and repair of the product.

WICONA® doc-0001149850_c        12.03.2019
                                                     5
WICLINE 115 AFS                                                       Technical Information
Integral sun blind
Operation and maintenance instructions

                                                                                                [int]

General instructions

ÂÂQuestions
Should you have further questions regarding the assembly or operation of your product, please
contact your authorized specialist shop.

ÂÂSpare parts / repairs
Available from WICONA. Only spare parts approved by WICONA may be used.

ÂÂLiability
In case of non-compliance with the instructions and information given in this manual, of improper
operation or when used outside the intended purpose, the manufacturer declines liability for dam-
ages to the product. Liability for consequential damage to elements of all types or persons is
excluded.

ÂÂLegal information
The graphics and textual parts of this manual have been produced with care. No liability is assumed
for possible errors and their effects! Technical modifications to the product as well as to these
instructions are reserved! The manual contains copyrighted information. All rights are reserved! The
product or brand names listed are protected trademarks.

WICONA® doc-0001149850_c      12.03.2019
                                                 6
WICLINE 115 AFS                                                         Technical Information
Integral sun blind
Operation and maintenance instructions

                                                                                                  [int]

CE marking

The WICONA composite window Venetian blinds VB 25 mm are declared in conformity with the
Machinery Directive or the directive on electromagnetic compatibility and fullfil the basic require-
ments of the harmonized standard EN 13120 when used as intended. The corresponding declara-
tion is deposited with the manufacturer.

The CE marking is valid for the condition of the product as delivered. When installed, the product
only fullfils the requirements of the mentioned standard if

ÂÂthe instructions and advice given in this manual have been followed during the installation.

ÂÂthe product has been installed with the recommended type and quantity of fixings.

Outside the instructions described in this manual, the product may not be modified, converted or
extended. Each modifcation, convertion or devices added on to this product, invalidates the dis-
played CE marking.

WICONA® doc-0001149850_c       12.03.2019
                                                  7
WICLINE 115 AFS                                                           Technical Information
Integral sun blind
Operation and maintenance instructions

                                                                                                     [int]

Safety instructions

             The installation instructions refer to finished elements made 100% out of our defined
             components, otherwise any type of liability will be declined!

             Before installation and operation, the safety instructions and information must be care-
             fully read. In case of non-compliance with the instructions and information given in this
             manual, of improper operation or when used outside the intended purpose, the manu-
             facturer declines liability for damages to the product. Liability for consequential damage
             to elements of all types or persons is excluded.

             • K eep to the described installation sequence and to recommendations and instruc-
                tions.
             • Please keep these instructions in a safe place.
             • All installation and dismantling as well as maintenance and repair activities are to be
                exclusively carried out by authorized or qualified professionals.
             • When using switching, automatic or radio control devices for the operation of the
                blinds, please follow the enclosed, relevant instructions of the manufacturer.
             • During operation, do not put your hand on or into moving parts.
             • Please make sure to avoid pieces of cloth or limbs getting trapped in the equipment.
             • Please be aware of the accident prevention instructions issued by the professional
                association!
             • Before operating the blind, please check it for any visible damages. Do not use a
                damaged blind and contact immediately authorized professionals.
             • Risk of injuries and accidents caused by the weight of the product!
             • Take safety measures against pinching risks, especially when using a setup with
                automatic devices.

              sun protection with an electric drive can not be retracted without electric current.
             A
             Therefore, especially for areas with frequent power failures, we recommend the preven-
             tive measure of fitting an emergency power supply.

              AUTION!
             C
             A closed sun protection is for children / adults no protection for a fall through the
             window!

WICONA® doc-0001149850_c         12.03.2019
                                                    8
WICLINE 115 AFS                                                          Technical Information
Integral sun blind
Operation and maintenance instructions

                                                                                                  [int]

Safety instructions

            Caution! Risk of injuries or death caused by electrocution!
            • Installation, testing, commissioning and troubleshooting of the system may only be
               carried out by an authorized or suitably qualified professional (acc. to VDE 0100).
            • When working on the system, make sure to switch off the power supply on all
               connecting leads! There is a risk of death! Take safety precautions against unin-
               tended switching on!
            • Check the electrical leads regularly for damages. Do not use the system any longer if
               any damage has been detected.
            • Our electrically driven systems comply with the requirements for power systems acc.
               to VDE 0100. We can not guarantee the operational safety of the system if unauthor-
               ized changes have been made.
            • Please follow the installation instructions enclosed with the supplied electrical appli-
               ances.

               Systems with motorized drive:
                The drives used run on 24 V direct current supply. Make sure to check the power
                supply of your network provider before connecting the system. A wrong voltage can
                destroy the the drives.

               CAUTION! Risk of strangulation:
               Children, in particular small children, can get entangled in the loops of strings or
               chains and strings for the operation of the system hanging inside and get strangled.
               There is a risk that strings or chains get rolled around the neck.
               To avoid this, make sure strings or chains are kept out of reach of children. Beds and
               pieces of furniture should not be located near the strings or chains.

               Strings may not be knotted together. Please ensure that strings do not get entangled
               and form a loop.

               Further, please make sure that suitable or enclosed holders are installed properly.

WICONA® doc-0001149850_c        12.03.2019
                                                   9
WICLINE 115 AFS                                                    Technical Information
Integral sun blind
Operation and maintenance instructions

                                                                                            [int]

Safety instructions

                            Travel range of the blind:
                            Please check that no obstacles are obstructing the travel range of
                            the blind.

                             Wrong operation:
                             Never push the blades up and do not pull them down, this could
                             cause malfunctions. Do not reach between moving parts.

                            Use outside the intended purpose:
                            Use the system exclusively for the intended purpose. A use outside
                            of this application can endanger the user and lead to damages to
                            the produkt. For example, do not put additional weights onto the
                            blind. With a use outside the intended purpose, the warranty claim
                            becomes invalid.

WICONA® doc-0001149850_c    12.03.2019
                                              10
WICLINE 115 AFS                                                      Technical Information
Integral sun blind
Operation and maintenance instructions

                                                                                               [int]
                            Access to operating devices:
                            Place the operating switch within sight of the system, however not in
                            the direct vicinity of the moving system parts. Do not let children play
                            with the operating units such as: remote control, switch or automatic
                            devices. There is a pinching risk especially when the system is oper-
                            ated with automatic devices.

                            Pay attention to the motor running time:
                            The motors used are not suitable for permanent running.

WICONA® doc-0001149850_c    12.03.2019
                                               11
WICLINE 115 AFS                               Technical Information
Integral sun blind
Operation and maintenance instructions

                                                               [int]

Intended use

• Sun protection

• Heat protection

• Privacy

• Anti-glare

WICONA® doc-0001149850_c    12.03.2019
                                         12
WICLINE 115 AFS                                                  Technical Information
Integral sun blind
Operation and maintenance instructions

                                                                                           [int]

Care, maintenance and repair

                                         Motor driven systems can be started unintentionally.
                                         During cleaning and maintenance work, the auto-
                                         matic control must be switched off and the power
                                         supply disconnected.

                                         Cleaning:
                                         Your systems may become dirty over time. The ser-
                                         viceability is not affected by this. The powder coated
                                         parts remain attractive for a longer time if they are
                                         regularly rubbed with a soft woollen cloth.

                                         Do not use solvents, alcohol (spirits) and abrasive
                                         cleaning agents. Wash away dirt from fingerprints,
                                         light grease or oil stains with a mild household
                                         detergent and a soft cloth. Rinse with clean water
                                         and dry with a soft cloth. Let it air dry!

                                         Never press too hard on the slats, otherwise they
                                         could be bent. Never use a high pressure washer.
                                         There is a risk that the surface of the slats may be
                                         damaged by pressure and heat.

WICONA® doc-0001149850_c    12.03.2019
                                          13
WICLINE 115 AFS                                                  Technical Information
Integral sun blind
Operation and maintenance instructions

                                                                                          [int]

Care, maintenance and repair

                                         Maintenance:
                                         Periodically inspect the system and controls for
                                         signs of wear and damage and the product for sta-
                                         bility.
                                         All inspection and maintenance work may only be
                                         carried out by a specialist company.
                                         Regularly check the electrical wiring of electrically
                                         powered systems for damage. Check the mechani-
                                         cal parts of your system for visible damage. Do not
                                         use the system if any damage is detected.

                                         Repair:
                                         Improper repairs can lead to danger to persons or
                                         damage to the system.

                                         Repairs may only be carried out by a corresponding
                                         specialist company.
                                         Only install original spare parts.

WICONA® doc-0001149850_c    12.03.2019
                                          14
WICLINE 115 AFS                                                  Technical Information
Integral sun blind
Operation and maintenance instructions

                                                                                           [int]

Operating instructions

                                         Motorized drive system
                                         By operating a switch, a remote control or an auto-
                                         matic device, the blind moves up or down. The end
                                         points of the drive are set at the factory. If a change
                                         is necessary, please refer to the enclosed instruc-
                                         tions of the motor manufacturer. By releasing a
                                         press switch, or by pressing the reverse or stop but-
                                         ton at a latching switch, the blind stops.

WICONA® doc-0001149850_c    12.03.2019
                                          15
WICLINE 115 AFS                                                               Technical Information
Integral sun blind
Operation and maintenance instructions

                                                                                                         [int]

Before the installation

                     Check the goods immediately for possible transport damage and for compliance
                     with the delivery note.

                     If any parts are missing or damaged, please contact WICONA immediately.

                     The packaging box should not be exposed to moisture. When transporting it
                     should be protected by foil to protect it against precipitation.

                     A moving of the blind system along the slat direction due to vibrations during
                     transport must be prevented.
                     The blind systems must be run to the upper end position for transport in order to
                     prevent the components from striking the glazing.

                     Carefully remove the packaging material, especially if using a knife make sure that
                     the contents of the packaging are not damaged!

                     Dispose of the packaging materials by recycling.

                     Warning!
                     Incorrect installation can lead to serious injuries. Please refer to the installation
                     instructions. Secure the installation location.

WICONA® doc-0001149850_c           12.03.2019
                                                       16
WICLINE 115 AFS                                                          Technical Information
Integral sun blind
Operation and maintenance instructions

                                                                                                [int]

Installation in the composite window

                   Installation of the blind
                   1. Raise the blind to the installation position.
                      Check the recess of the rebate insulation for cable loop.

                   2. Adjust the cable length of the cable transition.

                   3. Glaze in, align slats. Install glazing bead at side and bottom.
                   4. Connect the terminal to the cable end.
                      Make sure that no bare spots are visible on the cable end, which could lead to
                      short circuits. Electrical cables must be insulated when they come into contact
                      with conductive material. If necessary use shrink tubing.
                   5. Carefully handle the blind during mounting/cable connection in the composite
                      system. Ensure proper insertion of the upper rail.
                   6. Pull in the glazing bead all the way around!
                   7. After installing the blind, check function at the factory:
                      - Connect the test and adjustment device and make the blind run 1x down
                        and completely up.
                       - at cable transition 6081361 / 6081362 check if the window contact
                         functions.
                   8. At the construction site, after installing the windows and laying the cables,
                      remove the spacers between the upper rail and the slat. Afterwards it is recom-
                      mended to perform a functional acceptance test!

WICONA® doc-0001149850_c        12.03.2019
                                                   17
WICLINE 115 AFS                                                           Technical Information
Integral sun blind
Operation and maintenance instructions

                                                                                                       [int]

Electrical connection

The drive has three connections. Pin 1 and Pin 2 for the supply voltage. Pin 3 is used for the pro-
gramming of the drive.

The direction of rotation results from the application of the + voltage to Pin 1 or Pin 2. The drive
moves as long as the voltage is applied to the set upper or lower end position or to the external
switching sensor if no upper end position is set.

            De-energize the product and cables before connecting.

                                     For plug housing

                           Up                 Down
       Pin 1           +24 V            0 V (GND)
      Pin 2          0 V (GND)            +24 V

                                                                                       Pin 1 (red)
                                                                                       Pin 2 (black)
                                                                                       Programming pin
                                                                                       (green)

WICONA® doc-0001149850_c         12.03.2019
                                                        18
WICLINE 115 AFS                                                                            Technical Information
Integral sun blind
Operation and maintenance instructions

                                                                                                                [int]

Wiring diagram

            Note

The green wire (3) of the recommended cable (7) is only required for programming the end posi-
tions. In normal operation, the wire is not required and must therefore not be connected to the
motor control units.
• Insulate the green wire (3) against short circuits with an additional terminal or other measures!

       Wire assignment

                                                                   ① red (motor +)
                                                                   ② brown (motor -)
                               ⑦
                                                                   ③ green (programming pin)
                                            WICLINE 115              blue
                                                                   ④ AFS                     Technische Information
                                                                                                 Technical Information
                                               ① Sonnenschutz
                                            Integral sun protection⑤ yellow
                                            Integralem

                                                  ②
                                                                   ⑥ white
                                                   ③
                                                                   ⑦ 6081362
                                                 ④
                                                ⑤
                                            ⑥                  Cable transition 6081362 /
                                                                                6081361

    ① Terminal 1 = motor +
    ② Terminal 2 = motor -
    ③ Terminal 3 = Programming pin                                                               ⑩

    ④-⑥ Reserve cable
    ⑦ 6081362                                                                         ⑨    ⑪⑫
    ⑧ Plug                                                               ⑧
    ⑨ Mating plug                                                                           ⑬

    ⑩ Motor cable                                              ①②        12
                                                                              3
                                                        ⑦
    ⑪ Terminal 11 = motor + (red)                                                 ③
    ⑫ Terminal 12 = motor - (black)
                                                                          ④⑤⑥
    ⑬ Terminal 13 = Programming pin (green)

CAUTION

              Product damage through use of unsuitable motor control units or power supplies!
              •       Only use suitable power supplies and controllers!

                                            WICONA   1500807    REV. A        29.09.2017

WICONA® doc-0001149850_c       12.03.2019
                                                        19
WICLINE 115
WICLINE 115 AFS
            AFS                                                                  Technical
                                                                                  TechnischeInformation
                                                                                              Information
                                                                                      Technical Information
 Integral sun blind
Integralem    Sonnenschutz
 Operation
Integral      and maintenance instructions
         sun protection

                                                                                                         [int]

                                                  6081441                                 Cable end

                          4040106
                                                             Place cable loop!

                                    M

                                                                                               6081279

                                                                                               6081431

                                                                                               6081361/6081362

WICONA® 1500794
WICONA   doc-0001149850_cREV. A      12.03.2019
                                    29.09.2017
                                                            20
WICLINE 115 AFS                                                        Technical Information
Integral sun blind
Operation and maintenance instructions

                                                                                                 [int]

Test adjustment device for composite window Venetian blinds

1. General
With the test adjustment device for Venetian blind 4040106, in addition to the procedure in the UP or
DOWN direction, it is possible to set the end positions easily and to restore the factory settings. By
means of the buttons short command sequences are sent to the drive which are indicated by LEDs,
The test adjustment device is designed for the optional operation of the DC drives of the Venetian
blind 4040106 with 12 V or 24 V nominal voltage.

2. Normal operation
Using the UP or DOWN keys, the drives can be moved in the corresponding direction. The drives
move in each direction of rotation at creep speed for about 3 s and then go into fast speed. With the
transition to fast speed, the movement commands are stored. Stop by pressing the UP or DOWN
button again.

3. Assembly and connection

                                     to the drive

                                                         Run button UP

 LEDs for                                                Run button DOWN
 Status indicators
                                                         Programming button upper end position
                                                         Programming button lower end position
                                                         Restore factory settings

                     DC power supply 12V or 24V

WICONA® doc-0001149850_c       12.03.2019
                                                    21
WICLINE 115 AFS                                                       Technical Information
Integral sun blind
Operation and maintenance instructions

                                                                                                [int]
                              4. Restoring the factory setting
                              By pressing shortly the button „Default settings“ the factory settings
                              will be restored.

                              For the drive fitted to the blind, it is recommended, prior to restoring
                              the factory settings, to run the blind to its lower end position. After
                              restoring the factory settings, a position learning run can again be
                              started (see Pt. 5).

                              5. Commissioning
                              Upon delivery, the drive is in factory settings condition; the posi-
                              tion corresponds to the lower end position.

                              • Install the drive in the blind when it is let down.
                              • For the position teach-in run execute an up command, the
                                 drive can only be moved in the up direction.
                              • The drive goes into latching after 3 seconds.
                              • Run the drive until the mushroom button. After pressing the
                                 mushroom button, commissioning is completed.

                              After this position teach run, the upper end position (corresponding
                              to the mushroom button) and the lower end position are set. Fur-
                              ther adjustments are only necessary if deviating upper or lower end
                              positions are desired.

                              Warning: The drive determines the distance between the lower
                              end position and the actuation of the mushroom button during the
                              position teach run. In normal operation, if the mushroom button is
                              manually actuated, for example, before the actual end position of
                              the mushroom is reached, the drive stops. If the mushroom end
                              switch is no longer actuated, the run can be continued in the up
                              direction until the actual mushroom end position. If the run is con-
                              tinued in the down direction from the position at which the mush-
                              room button was manually operated, the drive runs the full distance
                              that it has determined during the position teach run; In this case,
                              the lower end position can be overrun. In a subsequent run in
                              the up direction, the drive in any case runs to the end of the mush-
                              room end switch and then has the correct distance back to the
                              lower end position.

WICONA® doc-0001149850_c    12.03.2019
                                               22
WICLINE 115 AFS                                                      Technical Information
Integral sun blind
Operation and maintenance instructions

                                                                                                [int]
                              6.  Setting the upper end position
                              •  The curtain must be below the upper end position
                              •  Press the programming key for the upper end position
                              •  The LEDs "UP" and "Position up" are lit.
                              •  Run until the upper end position via the control button "UP"; jog
                                  mode is possible.
                              • After reaching the desired upper end position, press the
                                  programming key "upper end position"; the adjustment process
                                  is completed.

                              Warning: The latching of the run commands is not active during
                              the setting the upper or lower end position.

                              7. Setting the lower end position
                              •  The curtain must be above the lower end position
                              •  Press the programming button for the lower end position
                              •  The LEDs "DOWN" and "Position down" are lit.
                              •  Run to the desired lower end position via the control button
                                “DOWN"; Jog mode is possible
                              • After reaching the desired lower end position, press the
                                 programming button "lower end position"; the adjustment
                                 process is completed.

                              Warning: The latching of the run commands is not active when
                              setting the upper or lower end position.

WICONA® doc-0001149850_c    12.03.2019
                                               23
WICLINE 115 AFS                                    Technical Information
Integral sun blind
Operation and maintenance instructions
Dimensions for ordering Venetian blinds VB 25                       [int]

            Designations

   FAB       Sash outer width
   FAH       Sash outer height
   XB        Order dimension width
   XH        Order dimension height
   PH        Pack height

WICONA® doc-0001149850_c         12.03.2019
                                              24
WICLINE 115 AFS                                                               Technical Information
Integral sun blind
Operation and maintenance instructions

Enquiry and order form for WICONA composite window Venetian blind                                    [int]

For the composite window WICLINE 115 AFS use preferably the tested and approved
WICONA Venetian blind VB 25. The ordering dimensions for width and height of the blind are
dictated by the clearance widths of the composite sash. See calculation formulas below.

XB     Blind order dimension width = FAB - 142 mm                See page „Ordering dimensions“ in the
XH     Blind order dimension height = FAH - 127 mm               „Technical Information“

Project                                                  Date / Company stamp

Project nr.

 Position Number Order dimension blind                Venetian blind:
                  Width XB    Height XH
                                                            4040106
                    (mm)        (mm)

Colour slat and bottom rail                    0609 (white) *                    �
                                               0717 (silver) *                   �
Colour head profile                            standard black coated similar C35

* to be checked regarding maximum admissible operating temperature

WICONA® doc-0001149850_c          12.03.2019
                                                       25
WICLINE 115 AFS                                                          Technical Information
Integral sun blind
Operation and maintenance instructions

                                                                                                   [int]

Transport recommendation

In this leaflet you will find our recommendations, hints and tips for the safe handling of our products.
The aim is to prevent accidents and injuries. Always wear the recommended personal protective
equipment (PPE).
Always remember safety!

For safe and professional transport and storage of the elements, use only suitable and designated
transport racks.

Safety notice:
• The transport racks must not be overloaded! Observe the maximum permissible payload. The
   individual elements must not exceed the depth of the support surface.
• The element is placed on the racks with a slight inclination on the transport units. If the angle of
   inclination is too small, the element can fall over without additional external influence.
• Racks must be secured against unintentional rolling away!
• Never store racks in traffic zones.

For compound windows with integral blinds, the following must be observed:
• Run the blind completely upwards
• Slide in spacers between the top rail of the plate pack and the uppermost slats for securing all
   ladder cords.

Transport and storage of the units:
• Upright element transport if possible.
• In the case of high elements, they can be transported lying vertically.
• Transport frame and leaf separately.
• If the frame and sash are transported together, distance blocks must be inserted between the
   frame and sash to relieve the load on the hardware.
• Please pay attention to proper shimming of the glass panes
• The elements must be stored in such a way that they cannot fall over.
• The supports and the anti-tilt device must not cause any damage to the element and must be
   arranged parallel to the surface of the element.
• Stacked elements must be protected with suitable intermediate layers.
• If possible, window elements must be stored in dry, well-ventilated and weatherproof rooms.
• For temporary storage in the open air and on construction sites, the element must be covered;
   e. g. by means of suitable tarpaulins or hoods.
• Window elements must also be protected against direct sunlight and moisture before installa-
   tion.
• This applies in particular to window elements that are glazed with coated or dyed glasses, orna-
   mental, cast and wire-reinforced glasses, as heat cracks can occur more frequently.

WICONA® doc-0001149850_c        12.03.2019
                                                   26
WICLINE 115 AFS                                                            Technical Information
Integral sun blind
Operation and maintenance instructions

                                                                                                     [int]
Professional transport of the racks by forklift or crane
• Make sure that the racks are only lifted at the designated places!
• If elements are transported above head height, helmets must be worn!

General information:
• The transport of heavy window units must be carried out in such a way that the element is not
   transported over the glass panes.
• Temporary lifting of the glazing unit on only one pane for manipulation and insertion is possible,
   but should be kept to a minimum.
• For transports with large differences in height (mountain passes, air freight) it is necessary to use
   a pressure compensating valve for multi-pane insulating glass due to the difference in air pres-
   sure from the interspace between the panes and the climate. The manufacturer of the insulating
   glass must be informed in advance!

Caution:
• Since a wide variety of high-quality products are used in windows, special attention must be paid to
   these. For example, you should request transport instructions / recommendations for the individual
   products, e. g. :
• Transport regulations of the blind manufacturers
• Transport regulations of the glass manufacturers

Recommendations on the correct handling of ready-to-install windows and external doors
can also be found in the VFF Leaflet TLE. 01 (October 2015)
Always remember safety!
Follow the recommendations and do not put yourself or third parties in danger.

WICONA® doc-0001149850_c        12.03.2019
                                                    27
WICLINE 115 AFS                                                           Technical Information
Integral sun blind
Operation and maintenance instructions

                                                                                                    [int]

Control guidelines for electrical systems

             The built-in motors are drives with integrated planetary gear, brake, top and bottom end
             switch and thermal protection switch, so they are not just electric motors, rather a com-
             plete drive system.

             In some respects the drives used DO NOT correspond to other commercial electrical
             consumers. It is therefore essential to observe the following notes and the safety instruc-
             tions.

             Installation, testing, commissioning and troubleshooting of the electrical system may only
             be carried out by a qualified electrician (according to VDE 0100). Improper connection
             can cause considerable danger for the user.

             •   Refer to the wiring diagram!
             •   We accept no liability for damages that could result from improper installation.
             •   Never run motors simultaneously with UP and DOWN signal!
             •   Keep switching pauses between UP and DOWN commands of approx. 0.5 sec-
                 onds (often neglected on Instabus EIB systems).

             Radio interference suppression
             The drives are suppressed according to valid VDE standards and EC directives. When
             operating with other devices containing sources of interference, the installer must ensure
             that the entire system complies with the applicable regulations due to the radio interfer-
             ence suppression requirement.

             Operation in wet areas
             The drives are splash proof, for use in wet areas, the VDE regulations among others
             0100/ part 701, 702 must be observed and complied with and also those of the local
             power supply company and TÜV.

             In addition to the instructions and notes documented in this manual, the instruc-
             tions and notes of the respective instruction manuals supplied by the drive
             manufacturers must be observed.

WICONA® doc-0001149850_c         12.03.2019
                                                    28
WICLINE 115 AFS                                                         Technical Information
Integral sun blind
Operation and maintenance instructions

                                                                                                 [int]

Control guidelines for blind motors

           Never connect more than one motor to a single pole switch!
           Only with group controls can several motors be operated with one switch.
           Switches for blind motors must be electrically and mechanically locked.

           Warning: If the above instructions are not followed, if the connections are not compliant
           with the standards or if the recognized regulations of technology are disregarded, neither
           the drive manufacturer nor WICONA shall be liable for any material or personal injury.
           Have the electrician confirm that the electrical connection has been carried out in accord-
           ance with the wiring diagrams (see instructions of drive manufacturer), the general
           instructions, the safety instructions and the control guidelines!

Electrical connection for blind motors

            Please refer to the chapters "Control guidelines for blind motors" and the "Safety
           instructions"!

                                                       Inis DC is suitable for
                                                       mounting in a ø60 mm flush
                                                       mounted switch box or in a
                                                       suitable surface mounted
                                                       cap.

                                            Legend

                                            ① Junction box

                                            ② Mains 230V / 50Hz

                                            ③ Drive

WICONA® doc-0001149850_c       12.03.2019
                                                  29
WICLINE 115 AFS                                                             Technical Information
Integral sun blind
Operation and maintenance instructions

                                                                                                      [int]

Commissioning / functional check

             Run the system up and down completely at least once. During extension, nobody should
             be in the travel range or under the system.

             After installing and setting up the composite windows in the façade, the blinds must be
             checked for damage and free running and can be adjusted if necessary.

             In the case of systems with a motor drive, automatic controls or switches must never be
             used for test runs where direct visual contact with the system is not guaranteed

             We recommend the use of a test cable for temporary motor operation.

             Check all settings.
             Check all connections for stability.
             Check again the fixing of the blind support on the mounting surface.

             Warning!
             Inadequate attachment of the stainless steel brackets can cause the system to crash;
             there is a risk of injury or death!

             Clean elements (see care tips).

             Hand over this manual to the user, as well as any instructions from the motor, switch and
             control manufacturers.
             Instruct the user, whereby you fully explain the safety and usage instructions for the system.
             Please confirm in writing the correct execution of the system, as well as the installation
             and instruction regarding the safety instructions (see handover protocol).

WICONA® doc-0001149850_c          12.03.2019
                                                     30
WICLINE 115 AFS                                                             Technical Information
Integral sun blind
Operation and maintenance instructions

                                                                                             [int]

Dismantling in general

           De-energize the system and secure it against being switched on again.

           Dismantling is carried out in the reverse order of the first installation.

WICONA® doc-0001149850_c        12.03.2019
                                                    31
WICLINE 115 AFS                                                       Technical Information
Integral sun blind
Operation and maintenance instructions

                                                                                          [int]

Handover protocol (for the installer)

Dear customer,
We are pleased that you have chosen a WICONA brand product. Our systems are manufactured
with the greatest care and with many years of experience.

                                           Your product
                           Composite window Venetian blind VB 25 mm
                              is manufactured according to EN 13120
                                               and

on the ………………………………………………………………………..………..

The operation and maintenance instructions have been handed over and must be read before using
the product.
Instruction has been provided.
The safety instructions, especially regarding child safety, were pointed out.

 The customer refuses installation in accordance with EN 13120 (child safety).
   (Please tick if necessary)

 Specialist company                               Customer

                                                  Surname                     Name

                                                  Street                      Number
 Name                        Date                 Postal code                 Place

 Place                       Signature            Date                        Signature

WICONA® doc-0001149850_c       12.03.2019
                                                 32
WICLINE 115 AFS                                                      Technical Information
Integral sun blind
Operation and maintenance instructions

                                                                                         [int]

Handover protocol (for the user)

Dear customer,
We are pleased that you have chosen a WICONA brand product. Our systems are manufactured
with the greatest care and with many years of experience.

                                           Your product
                           Composite window Venetian blind VB 25 mm
                              is manufactured according to EN 13120
                                               and

on the ………………………………………………………………………..………..

The operation and maintenance instructions have been handed over and must be read before using
the product.
Instruction has been provided.
The safety instructions, especially regarding child safety, were pointed out.

  he customer refuses installation in accordance with EN 13120 (child safety).
T
 (Please tick if necessary)

 Specialist company                              Customer

                                                 Surname                     Name

                                                 Street                      Number
 Name                        Date                Postal code                 Place

 Place                       Signature           Date                        Signature

WICONA® doc-0001149850_c       12.03.2019
                                                33
34
WICLINE 115 AFS                                                        Technical Information
Integral sun blind
Non-fault catalogue composite Venetian blind VB 25

                                                                                                [int]

Non-fault catalogue composite Venetian blind VB 25

This document is intended to provide assistance in assessing complaints.
The bases for the assessment are the guidelines and standards, if they exist.
If the documentation is used further, the source references must be given!

Note: Tolerances refer to the maximums of systems approved in the standard!

Blind height-width ratio
If the height-width ratios of 1:4 or hanging widths
WICLINE 115 AFS                                                        Technical Information
Integral sun blind
Non-fault catalogue composite Venetian blind VB 25

                                                                                                 [int]

1. Standards and guidelines

Guideline for the evaluation of the product characteristics of external Venetian blinds (ITRS)
Guidelines for evaluating the product properties of roller shutters - BUNDESVERBAND ROLLLADEN
+ SONNENSCHUTZ e.V.
Technical guideline for roller shutters - BUNDESVERBAND ROLLLADEN + SONNENSCHUTZ e.V.
Guidelines for the assessment of prefabricated awning fabrics - Bundesverband Konfektion Tech-
nischer Textilien e.V.

Leaflet "Visual assessment of anodized surfaces on aluminium" - Verband der Fenster- und Fas-
sadenhersteller e.V.
Leaflet "Visual assessment of organic coated (painted) surfaces on aluminium" - Verband der Fen-
ster- und Fassadenhersteller e.V.
Leaflet "Filiform corrosion - Avoidance in coated aluminium components" - Verband der Fenster- und
Fassadenhersteller e.V.

DIN EN 13120 Inner terminations - Performance and safety requirements
DIN EN 13561 Awnings - Performance and safety requirements
DIN EN 13144 Metallic and other inorganic coatings - Method for quantitative measurement of ten-
sile strength by tensile test
DIN 18073 Shutters, awnings, roller shutters and other closures in construction - terms, require-
ments
DIN 18202 Tolerances in building construction - Structures
DIN 17611 Anodized aluminium and wrought aluminium alloys - Technical delivery conditions
EN ISO 4623-2 Coating materials - Determination of resistance to filiform corrosion - Part 2: Alumin-
ium as a substrate

WICONA® doc-0001149850_c       12.03.2019
                                                  36
WICLINE 115 AFS                                                                                   Technical Information
Integral sun blind
Non-fault catalogue composite Venetian blind VB 25

                                                                                                                               [int]

1.1 Composite window Venetian blinds

This section deals with features of complaints regarding indoor blinds.
Features that affect all products, such as coating, etc. are covered in a separate section.

  Complaint - character-                                  Description                                           Tolerance
          istic
System heights                     up to 2000 mm                                                   +/- 5 mm
                                   over 2000 mm                                                    +/- 8 mm

                                   Permanent dimensional accuracy                                  +/- 3%
System width                       up to 2000 mm                                                   +/- 2 mm
                                   up to 4000 mm                                                   +/- 4 mm
                                   over 4000 mm                                                    +/- 6 mm

                                   Permanent dimensional accuracy                                  +/- 0.5%
Packaging height                                                                                   +/- 10 mm
Parallelism package                over system width                                               see chapter 1.2
Slat closure                       Slats must cover each other when closed (horizontal
                                   view)
Angular position of slats                                                                          +/- 5°
Angle difference of the slats to                                                                   Max. 10°
each other
Slat rotation                      Angular deviation between one end of the slat and the           Max. 2 mm per metre or for
                                   other end.                                                      lengths less than 2 metres ->
                                                                                                   max. 4 mm

Slat curvature / bulge             Deviation of a slat edge C with a length L from the             C = 1/2 L²
                                   straight line, if this lies on a flat surface. C in mm, L in
                                   metres

Bending of closed slats            up to 1500 mm                                                   Max. 5 mm
                                   up to 2500 mm                                                   Max. 10 mm
                                   up to 3500 mm                                                   Max. 15 mm
                                   over 3500 mm                                                    Max. 20 mm
Noise transmission                 Slight noise and vibration transmission to the structure
                                   is permitted and is the current state of technology.

WICONA® doc-0001149850_c               12.03.2019
                                                                  37
WICLINE 115 AFS                                                                             Technical Information
Integral sun blind
Non-fault catalogue composite Venetian blind VB 25

                                                                                                                            [int]

Slanting of the bottom rail (with   Deviation from horizontal;                               Max. 15 mm
parallel slat package)              Deviation from vertical;
                                    (for each point between the fully retracted and
                                    extended position); for systems 1.5 and the width is >600 mm, we guarantee a maximum skew of 15 mm/m of curtain height,
based on the ITRS definition. For width
WICLINE 115 AFS                                                          Technical Information
Integral sun blind
Non-fault catalogue composite Venetian blind VB 25

                                                                                                   [int]

2. Surface treatment

2.1 Anodizing

The guideline is based on the leaflet "Visual assessment of anodized surfaces on aluminium". This
guideline was published by the Association of Windows and Façade Manufacturers - Issue October
2007.
This guideline applies to products in ready to install or installed state.

The anodically produced surface must comply with DIN 17611 or the standards cited there and the
Qualanod regulations.

Test

When checking for characteristics, the visual plan view of the visible surface is decisive. The test
is usually performed on external surfaces at a distance of 5 metres and on internal surfaces at a
distance of 3 metres.

Exterior surfaces should be inspected with diffused exterior light, inside surfaces with normal illumi-
nation, at a viewing angle perpendicular to the surface.

Requirement

The abnormalities of the characteristics are strongly influenced by the gloss level of the surface. The
higher the gloss level, the more noticeable the characteristics appear.

Explanation of the table:

●●●    Surface with high demand
●●     Surface with usual demand
●      Surface with little or no demand

X      Characteristic is permitted
Φ      Characteristic is conditionally permitted
-      Characteristic is not permitted

WICONA® doc-0001149850_c        12.03.2019
                                                   39
WICLINE 115 AFS                                                                            Technical Information
Integral sun blind
Non-fault catalogue composite Venetian blind VB 25

                                                                                                                            [int]

                                                                            MINIMUM REQUIREMENTS

              Assessment criteria,                                                  Anodized
            characteristics and level
3.1   Silicon excretions                 •••     -
                                         ••      -
                                         •       X
3.2   Bridge marks, coarse grain         •••     Φ   permitted if pickling treatment E0/E6 according to DIN 17611 is present
                                                     or if not conspicuous in other pretreatment processes (respect viewing
                                         ••      Φ   distances according to point 2)
                                         •       X
3.3   Pre-corrosion                      •••     Φ   permitted, if not conspicuous for pickling treatment E0/E6 according to
                                                     DIN 17611
                                         ••      Φ
                                         •       X
3.4   Gloss differences                  •••     Φ
                                         ••      Φ
                                         •       X
                                                     In the case of technical measurement evaluations by reflection measure-
                                                     ment according to EN 12373-11 (85° measuring geometry), maximum
                                                     differences between the assembled parts of 20 units usually apply.
                                                     In this case, only profiles and sheets can be compared with each other,
                                                     which are natural or anodized in a one and two stage process.
3.5   Colour variations                  ••• Φ       permitted, if not conspicuous (respect viewing distances according to
                                                     point 2). In weld seams unavoidable.
                                         •• Φ
                                         •   X
                                                     Only profiles and sheets can be compared with each other under consid-
                                                     eration of the rolling/pressing direction. Possibly limiting samples between
                                                     contracting parties must be agreed separately according to the type of
                                                     semi-finished product.
3.6   Welds with grinding marks or       •••     Φ   permitted, except if decorative sanding is expressly agreed
      dents
                                         ••      X
                                         •       X
3.7   Semi-finished bumps (dents),       •••     X
      pull marks, longitudinal welds,
      impressions, structures
                                         ••      X
                                         •       X
3.8   Production related mechanical      •••     Φ   permitted, if not conspicuous (respect viewing distances according to
      damage (e.g. dents, bumps,                     point 2)
      scratches)
                                         ••      Φ

                                         •       X
3.9   Compaction coating (iridescent     •••     X   Not avoidable especially with dark colours.
      layer formation)                               (can be eliminated by abrasive thorough cleaning).
                                         ••      X
                                         •       X

WICONA® doc-0001149850_c                12.03.2019
                                                               40
WICLINE 115 AFS                                                          Technical Information
Integral sun blind
Non-fault catalogue composite Venetian blind VB 25

                                                                                                   [int]

2.2 Powder coating

The guideline is based on the leaflet "Visual assessment of organically coated (painted) surfaces on
aluminium". This guideline was published by the Association of Windows and Façade Manufactur-
ers - Issue October 2007.
This guideline applies to products in ready to install or installed state.

The coated surface must comply with the international quality guidelines for coated surfaces of alu-
minium components GSB - AL631 or Qualicoat.

Test

When checking for characteristics, the visual plan view of the visible surface is decisive. The test
is usually performed on external surfaces at a distance of 5 metres and on internal surfaces at a
distance of 3 metres.

Exterior surfaces should be inspected with diffused exterior light, inside surfaces with normal illumi-
nation, at a viewing angle perpendicular to the surface.

Requirement

The abnormalities of the characteristics are strongly influenced by the gloss level of the surface. The
higher the gloss level, the more noticeable the characteristics appear.

Explanation of the table:

●●●    Surface with high demand
●●     Surface with usual demand
●      Surface with little or no demand

X      Characteristic is permitted
Φ      Characteristic is conditionally permitted
-      Characteristic is not permitted

WICONA® doc-0001149850_c        12.03.2019
                                                   41
WICLINE 115 AFS                                                                           Technical Information
Integral sun blind
Non-fault catalogue composite Venetian blind VB 25

                                                                                                                           [int]

                                                                           MINIMUM REQUIREMENTS

             Assessment criteria,
                                                                                  Industrially
            Characteristics and level                                               coated
3.1   Craters, blisters                 ••• Φ        Permitted, if not conspicuous, Ø
WICLINE 115 AFS                                                                                Technical Information
Integral sun blind
Non-fault catalogue composite Venetian blind VB 25

                                                                                                                                [int]

3.7    Colour variations                   ••• Φ          permitted, if not conspicuous (respect viewing distances according to
                                                          point 2)
                                           •• Φ
                                           •   X
                                                          In the case of arbitration, a measuring assessment in accordance with
                                                          ISO 7724 with 45°/0° or 0°/45° measurement geometry according to DIN
                                                          6174 for single colour, smooth coatings of a coater and coating system
                                                          can be carried out.
                                                          The numerical value of colour deviations within an original painting of
                                                          immediately adjacent parts should not exceed ΔE ab according to the
                                                          table. These deviations do not apply to colour cards, as they are coated
                                                          with other coating systems, but describe the uniformity of the colour of
                                                          two adjacent components. An absolute colour deviation can only be
                                                          determined for an agreed sample sheet.
                                                           Colour group       Maximum colour difference
                                                                              ΔE from up to max. 1 year after
                                                                              installation
                                                           A L value > 85                    0.8
                                                           A L value 60-85                   1.0
                                                           A L value < 60                    1.3
                                                           B                                 1.8
                                                           C                                 2.3
                                                           D                                 3.0

                                                          In the case of a spatial separation of the component surfaces through
                                                          beads, trim strips, cavities, etc., this tolerance may be increased by 0.2.
                                                          For components coated by different coaters using the same coating
                                                          system, this tolerance should be increased by 0.6.
                                                          Thermally curing lacquer systems are repaired after mechanical damage
                                                          with reaction hardening liquid lacquers (2-K polyurethane). Due to dif-
                                                          ferent weathering behaviour (especially UV radiation), colour differences
                                                          may occur over time. This can not be avoided according to the current
                                                          state of technology.
3.8    Welds with grinding marks or        •••        Φ   permitted, except if decorative sanding is expressly agreed
       dents
                                           ••         X
                                           •          X
3.9    Semi-finished bumps (dents),        •••        X
       pull marks, longitudinal welds,
       impressions, structures
                                           ••         X
                                           •          X
3.10   Production related mechanical       •••        Φ   permitted, if not conspicuous (respect viewing distances according to
       damage (e.g. dents, bumps,                         point 2)
       scratches)
                                           ••         Φ
                                           •          X

WICONA® doc-0001149850_c                 12.03.2019
                                                                   43
WICLINE 115 AFS                                                          Technical Information
Integral sun blind
Non-fault catalogue composite Venetian blind VB 25

                                                                                                  [int]

2.3 Filiform corrosion

The guideline is based on the leaflet "Filiform corrosion - prevention of coated aluminium compo-
nents". This guideline was published by the Association of Windows and Façade Manufacturers -
Issue March 2009.

Introduction

This form of corrosion occurs when chloride containing constituents of the atmosphere act on
coated steel or coated aluminium. This type of corrosion differs from other forms of corrosion by the
typical thread-like course.

Filiform corrosion is observed for example on offshore islands as well as coastal areas, in some
types of swimming pools and occasionally due to direct salt gritting contamination.
The risk area decreases with increasing distance from coastal areas - up to 30 km.

Influencing factors

• T he main criterion is the presence of chlorides, which in connection with humidity leads to the
   formation of electrolytes
• Current pretreatment processes (chromate coating according to EN 12487) can not prevent the
   occurrence of filiform corrosion with absolute certainty
• All standard paint systems can exhibit filiform corrosion after appropriate weathering time, if they
   are provided with a pretreatment based on yellow or green chromate coating or chromium free
   systems
• Filiform corrosion occurs mainly at processing areas such as cut edges, drainage openings,
   mechanical damage (scratches), rarely at defects of the pretreatment and the paint film
• With appropriate regular cleaning the development of filiform corrosion can be delayed
• Filiform corrosion can occur with all aluminium alloys used

WICONA® doc-0001149850_c       12.03.2019
                                                  44
WICLINE 115 AFS                                                         Technical Information
Integral sun blind
Non-fault catalogue composite Venetian blind VB 25

                                                                                                 [int]

3. Test

The filiform corrosion resistance of the applied coating can be determined by a test according to EN
ISO 4623-2.
Resistant systems show no substantial infiltration of the paint film during the test after 1000 hours.

Pretreatment

According to the current state of knowledge, filiform corrosion in areas at risk can be avoided with
certainty only by pre-anodization instead of a chromate pretreatment.
In contrast to normal anodization, the process is performed at significantly higher electrolyte tem-
peratures and high current densities in a sulphuric acid bath.

Repair of damaged components

For the renovation, the damaged area is locally sanded down to the base material and additionally
provided with a zinc primer. After that, the top coat is applied.

visible surfaces of slats

WICONA® doc-0001149850_c       12.03.2019
                                                  45
Austria                        Hungary                                                           Slovenia
5201 Seekirchen                1031 Budapest                                                     2201 Zg. Kungota
   +43 6212 2000                  +36 (1) 4533457                                                    +386 26 20 99 70
   info@wicona.at                 info@wicona.hu                                                     info@wicona.de

Benelux                        Ireland                                                           Sweden
3400 Landen                    Dublin D22 X286                                                   574 81 Vetlanda
   +32 11 690316                    +353 1 4105766                                                   +46 470 78 74 00
   info@wicona.be                   info@wicona.ie                                                   wicona@wicona.se
   info@wicona.nl

Croatia                        Italia                                                            Switzerland
43000 Bjelovar                 20063 Cernusco sul Naviglio MI                                    5506 Mägenwil
   +385 43 22 25 46                 +39 02 924291                                                   +41 62 88741-41
   info@wicona.de                   info@wicona.it                                                   info@wicona.ch

Czech Republic                 Lithuania / Latvia                                                United Kingdom
619 00 Brno                    02244 Vilnius                                                     Wakefield WF5 9TG
    +420 602 745 407               +370 5 2102587                                                    +44 1924 232323
    info@wicona.cz                 info@wicona.lt                                                    info.wiconauk@wicona.com

Denmark                        Norway
8240 Risskov                   2007 Kjeller
   +45 7020 2048                  +47 22 42 22 00
   wicona@wicona.dk               wicona@wicona.no

España                         Poland                                                            China
08195 Sant Cugat del Vallès    93-428 Łódź                                                       Beijing 100005, P.R.C
Barcelona                          +48 42 683 63 73                                                   +86 10 6059 5686 ext. 805
    +34 93 573 77 76               info@wicona.pl                                                     contact.wicona.international@wicona.com
    wicona.es@wicona.com

Estonia / Latvia               Romania                                                           Singapore
75312 Rae vald Harjumaa        031041 Bucharest                                                  608831 Singapore
    +37 2657 6635                 +40 21 3260045                                                     +65 6513 2126
    info@wicona.ee                info@wicona.de                                                     contact.wicona.international@wicona.com

France                         Serbia                                                            United Arab Emirates
02200 Courmelles               11070 Beograd                                                     Dubai
    +33 3 23598200                 +381 11 312 18 35                                                 +971 4 887 00 96
    info@wicona.fr                 info@wicona.de                                                    contact.wicona.international@wicona.com

Germany                        Slovakia                                                          Other countries
89077 Ulm                      82105 Bratislava                                                  31037 Toulouse
   +49 731 3984-0                  +421 918 725 098                                                 +33 5 61312626
   info@wicona.de                  info@wicona.sk                                                   contact.wicona.international@wicona.com

All contacts: www.wicona.com   Note: Not all presented products are available in all countries
T E C H N I K   F Ü R   I D E E N

www.wicona.com
You can also read