VENTILUX THE EMERGENCY LIGHTING SPECIALISTS MANUFACTURING WORLD-CLASS EMERGENCY LIGHTING SOLUTIONS IN IRELAND FOR OVER 30 YEARS 1 2019 Edition
Background The Head Office in Bray, Co.Wicklow, Ireland, is the centre of the Ventilux operation, with over 35,000 sq. ft. of state-of-the-art production facilities, research and development laboratories, in-house training centre and global distribution warehouse. Liverpool is the UK base for distribution, sales order processing and in-house conversions. Ventilux designs, manufactures and offers an extensive range of safety system products and services, including Emergency Lighting, Central Battery Systems, Luminaire Conversion Equipment, Nurse Call, Emergency Lighting Commissioning, Service and Maintenance. Ventilux was founded in 1986, and has since grown steadily to become one of the largest Independent Emergency Lighting Manufacturers in Europe & the Middle East. Ventilux operate, and are certified to, ISO 9001:2015. Modern manufacturing technology combined with stringent quality control ensures that Ventilux products provide the customer with top quality and excellent value for money. In Ventilux we have a highly experienced and talented R&D Department who are consistently designing products that reduce contractors’ project costs and also reduce our clients’ day-to-day costs. Failure Rate (Currently 1 in 1,000 luminaires) Since our founding in 1986, Ventilux has believed that quality of product and service is the most important aspect of our business. We recognise the value of having the ability to demonstrate our commitment to quality, both to existing and potential customers. The responsibilities of the Ventilux Quality Team, include, amongst other things retention of the ISO 9001 certification through annual audits with NSAI (National Standards Authority Of Ireland). The team plays an integral part in monitoring returns of all Ventilux products which currently runs a rate of 1 in 1,000 fittings manufactured. BSI Kitemark The BSI Kitemark is a registered certificate mark owned and operated by the British Standards Institute (BSI). It is one of the most recognised symbols of quality and safety in the world and offers true value to customers, business and procurement practices. Ventilux were audited before they were awarded a Kitemark licence, then our production facilities are re-audited twice annually to maintain our Kitemark licences. In addition our emergency lighting products are re-audited twice annually to ensure that they maintain the same quality, safety and compliance to EN60598-2-22. Combined with the world renowned and independent backing of the British Standards Institute – a UKAS accredited organisation no other certification mark carries the same weight or significance as the BSI Kitemark. As the BSI Kitemark is a voluntary certification system it shows Ventilux’s commitment to delivery of safe, reliable and compliant emergency lighting products to the end user. Because of this, you will know from the start that your emergency lighting products will consistently deliver the highest standards of Kitemark quality. When a lighting product attains the BSI Kitemark, it sends out a clear message to consultants and electrical contractors that the highest standards of quality, safety and compliance are consistently being achieved. ISO 9001:2015 Ventilux was awarded ISO standard in 1993. This standard, which was designed and is updated at regular intervals by industry experts is an extremely effective way for businesses to ensure that all controls required to guarantee consistency of quality are in place, and regularly reviewed. The Ventilux Quality Team are available to deal with, and bring to a swift resolution, any customer queries or problems. Customer satisfaction is of paramount importance to all Ventilux Employees, and is our commitment to the customer, which we believe has contributed to our success and longevity. Quality Policy It is the policy of Ventilux Limited to operate a Quality Management System that will meet applicable requirements. Our Quality Management System will be appropriate to the purpose and context of the organisation, and support its strategic direction. Ventilux Limited will strive to create a quality philosophy of “Getting it right first time” through achieving and reviewing quality objectives, where all employees play an integral part in continuous improvement of the effectiveness of the Quality Management System. The quality policy, mission statement, and the requirements of the Quality Manual are issued on the authority of Senior Management and their implementation is mandatory. Ventilux Warranty Policy For up to date warranty terms and conditions please contact Ventilux sales office. sal-103-03 “Our Mission is to become a World Class Supplier of Emergency Lighting and Associated Testing System. By involving all employees in exceeding our customers expectations, we will provide the highest quality of products, service and delivery at a competitive price, thereby ensuring the profitable long term growth of the company.” Brendan Walsh Brendan Walsh MAI, MSc, CEng 2 Chairman 3
design & systems NE TCOM5 BAT TERY PAGE 6 Lighting design & SELF CONTAINED self TEST DALI NETCOM 5 XP CENTRAL Bespoke Project testimonials PAGE 10 PAGE 11 PAGE 12-13 PAGE 14-15 BATTERY SYSTEMS products PAGE 16-21 support PAGE 8-9 PAGE 74 PAGE 75 escape Routes PAGE 22 OPTILENS OPTILENS HALO HALO IP65 OPTIC OPTIc EYECON DELTA VISOR 120 PAGE 26 PAGE 28 PAGE 29 PAGE 32 PAGE 33 PAGE 34 SURFACE MOUNT recessed SURFACE MOUNT PAGE 27 PAGE 30 PAGE 31 WEATHERPROOF HI-LITE SKYLUX SCOUT I-LUX COMPACT TWINLUX COMPACT TWINLUX WEATHERPROOF WEATHERPROOF PAGE 35 PAGE 36 PAGE 37 PAGE 38 PAGE 39 PAGE 41 TWINLUX LED led TWINLUX PAGE 40 PAGE 42 PAGE 43 ETS IP65 TWINSPOT LED SIRIUS NOVA APOLLO evolux 3w visor mains lighting evolux 5w vega PAGE 44 PAGE 45 PAGE 46 PAGE 47 PAGE 48 PAGE 48 PAGE 49 PAGE 49 conversion service PAGE 50 exit signage PAGE 54 MULTILUX BLADE MULTILUX ATLANTIC ATLANTIC EB VASARI VANGUARD STYLUX RECESSSED STYLUX vista PAGE 58 PAGE 59 PAGE 60 PAGE 61 PAGE 62 PAGE 63 PAGE 64 PAGE 65 PAGE 66 Vista ds EXLUX EXLUX PLUS EXLUX IP67 VISOR DS IP65 FUSION VELA eb VISOR EXIT PAGE 67 PAGE 68 PAGE 69 PAGE 70 PAGE 71 PAGE 73 4 PAGE 72 PAGE 72 PAGE 73 5
systems & LIGHTING DESIGN SYSTEM EMERGENCY LIGHTING DESIGN P-08 Overview Design standards Level of competence Method of approach Site Installation SELF CONTAINED SYSTEMS P-10 Overview ELT Central test unit specification SELF TEST SYSTEMS P-11 Overview Benefits of Self test Luminaires Self test diagnostic indicators DALI SYSTEMS P-12 Overview Benefits of DALI DALI power supply DALI controller NETCOM 5 SYSTEMS P-14 Overview Benefits of Netcom 5XP Why Netcom 5XP Netcom 5XP Control module CENTRAL BATTERY SYSTEMS P-16 Overview System operation description Selecting a static inverter Battery analysis care systems (BACS) 6 7
STANDARDS LIGHTING DESIGNS Lighting design LIGHTING DESIGN OVERVIEW PROJECTS VENTILUX prides itself on its flexible Engineering Design Department. This department consists of technical expert Ventilux have undertaken many emergency lighting projects across Europe and the Middle East, and are able to engineers, all highly trained & dedicated to developing cost effective Emergency Lighting designs. Our design experts supply our products globally. plan, budget and design for client specific requirements. Our design team utilise various state-of-the-art design software packages to ensure quality and compliance in our Emergency Lighting designs. design standards central battery systems Ventilux provides designs to markets all across the world and ensure that the designs created are meeting the required This state-of-the-art entertainment venue, which is one of the most advanced arenas in the world is situated in the heart of Dublin’s standards, for example: docklands. Ventilux supplied the central battery system for the emergency lighting, along with conversions of the emergency luminaires. • Irish Standards (NSAI-I.S 3217.2013 + A1:2017). • British Standards (BS 5266) • Qatar Civil Defence (QCD) • UAE Standards (NFPA 101) level of competence Netcom 5xp site installation All Ventilux lighting design engineers have completed the QQI Level 6 certificate training in Emergency Lighting Liverpool One is a major development in the heart of Liverpool city centre. It comprises 30 major new buildings including 2 Design and Commissioning. department stores, banks, hotels, restaurants and luxury residential accommodation in 42 acres between Liverpool City Centre and the Albert Dock. Ventilux has the ability to project manage small, medium and large projects, from design phase to commissioning and In what is believed to be the largest emergency lighting installation in Europe with centralised monitoring and testing facilities, handover. We have specialist engineers to provide technical Ventilux supplied emergency luminaires, central battery supplies and a central test and monitoring system, for the Paradise Project assistance at all times to ensure complete peace of mind. in Liverpool. method of approach Dali site installation Ventilux utilises state-of-the-art design software platforms like CAD/Dialux to provide efficient and compliant lighting Facebook has expanded its international headquarters in Dublin.The company moved to a new 120,000sq.ft office space in Grand designs. The client would be provided with a dialux report which enables them to get a clear indication of various light Canal Square. The Ventilux Optic LED was selected as the Escape Route Lighting to be used in the offices. The discreet and aesthetic intensity and lux level requirements. The designs are modelled in Dialux platform (2D & 3D) and then regenerated in look accompanied with high efficient LED’s, reliable product quality and product value, were some of the criteria used in the Auto CAD (2D). Ventilux can also offer a pre-design walk on site (If required). selection process by our client. The Exit Sign selected was our hugely popular Glade LED. Engineered with ease of installation and cost effectiveness as a focus, the Glade LED achieves its goals while offering an exciting aesthetic to rival any edge lit sign on the market. 8 9
systems systems SELF CONTAINED - elt central test unit self-test overview overview For Self-Contained (Single Point) and Central Battery Systems The Ventilux Self-Test feature is a stand-alone integral testing self test diagnostics INDICATOR self test diagnostics INDICATOR Emergency Lighting Luminaires. In order to comply with solution for small to medium size installations. The Self-Test EN50172 an emergency lighting installation must be tested colour time sequence Status module is able to perform a test sequence and report the periodically by simulating failure of the normal supply. A permanent green - HEALTHY health of the battery, lamp or charger via a Tri-Colour LED. facility to simulate this failure must be provided. Under IS Preprogrammed to the testing requirements of EN50172 the 3217 this facility must not interrupt the normal or switched flashing green (0.1 SECOND ON/OFF) FUNCTIONAL TEST Self-Test module offers a cost competitive solution and peace supply to the area concerned, i.e. only the permanent supply slow flashing green (1 SECOND ON/OFF) DURATION TEST of mind where automated testing is concerned. may be interrupted and the test facility must automatically restore this supply at the end of a specified test period. The permanent red - LAMP FAILURE Key benefits of self-test Ventilux Central Test Unit allows the supply to be interrupted slow flashing red (1 SECOND ON/OFF) BATTERY FAILURE and then restored automatically, and so enhances system reliability. fast flashing red (0.5 SECOND ON/OFF) CHARGER FAILURE • Intelligent testing module, which can monitor and test self-contained emergency luminaries. SPECIFICATION • Supports fluorescent, incandescent and L.E.D self- contained fittings. • On/Off key-switch to prevent unauthorised use. • Ideal for small installations. • Power On Indication. • Compact size allows ease of installation. • Accurate crystal controlled timer/Digital display of • Provides easy to interpret visible fault and diagnostic elapsed time. indicators. • Test periods of 40min/1 hour/3 hours. (Other periods on • Low cost automated testing solution. request). • Offers long term cost saving on future maintenance costs. • Test in progress indication & Test completed indication. • Fully compliant to BS5266 and EN62034. • Audible warning on start of test and final 10 minutes of emergency lighting tester (elt) specification • Peace of mind that your system is fully compliant with test. order code elt/1 elt/2 elt/10 national standards. • Automatic restoration of supply on completion of test. input voltage 230v +/- 10% 50/60 hz • The Self-Test also provides a solution where a CTU is not • 10A multi-pole contactors. test duration 40 minutes. / 3 hours available. • Multi-zone versions available with individual zone select ip rating ip40 timings. dimensions (mm) 311 x 227 x 88 311 x 227 x 88 311 x 227 x 88 • 220V/240V 50/60Hz, 20VA (Other voltages available). no. of contractor 2 nc (normally 4 nc (normally 10 volt free connections closed) closed) contacts cable entry rear 20mm conduit entries weight 3.44 kg 3.44 kg 3.44 kg environment 0° C to +30° C, Up to 80% Relative Humidity housing material powder-coated mild steel warranty 3 years 3 years 3 years interface unit (ifu) specification order code ifu6 ifu12 ifu18 ip rating ip40 dimensions (mm) 325 x 227 x 85 365 x 280 x 68 465 x 280 x 68 no. of contractor 6 nc (normally 12 nc (normally 18 nc (normally connections closed) closed) closed) cable entry 2x 20mm conduit entries on top and rear surfaces SELF TEST DIAGNOSTIC INDICATOR weight 2.8 kg 5.1 kg 5.3 kg manual Push test button environment 0° C to +30° C, Up to 80% Relative Humidity housing material powder-coated mild steel 10 warranty 3 years 3 years 3 years 11
dali systems systems Dali addressable testing SYSTEM Dali power supply Dali controller overview overview overview DALI (Digital Addressable Lighting Interface) is an intelligent addressable The Ventilux DALI power supply controller is used for The Ventilux DALI controller combines safety with convenience emergency lighting testing solution. It allows an installation to be FULL DALI SYSTEM DEMO VIDEO supplying power to DALI devices without their own power and flexibility. With a larger screen and higher resolution, up to supervised, tested and monitored from a central location. It negates FIND US AT: VENTILUX EMERGENCY LIGHTING supplies and is suitable for mounting in switching cabinets. 120 emergency light control units can now be managed even the necessity for a maintenance engineer to physically/visually check all more conveniently. The 7” touch screen displays emergency emergency luminaires on a weekly basis as is currently required under SPECIFICATION light systems clearly and concisely. If a fault occurs somewhere EN50172 legislation. It also allows the site to be tested in non-working in the system, this is displayed on the touch panel in an easily dali system characteristics hours. Remote access and monitoring is now easier via the intranet and • For supplying 240 mA for DALI devices or control understandable and clearly visible way. Access to each individual Internet – less disruption to working environment, hence saving the end position code modules without their own power supplies component is with the touch of a finger, and a simple navigation user money. Modular design allows both small and large installations to max number of control modules 28 • For installation in switching cabinets system guides users reliably through control and management. be competitively specified. OPEN PROTOCOL allows other DALI emergency • 3 year guarantee lighting products to be used on the system. Considerable cost saving max luminaires per control module 120 SPECIFICATION against evergrowing maintenance costs. max luminaires per dali system 3,360 DALI POWER SUPPLY max cable distance from last luminaire to control module 300 meters why dali? system mode dali power supply • Background lighting with RGB LEDs. max cable distance from control module to central hub 2 kilometers part number vent / dali / psu • With DALI system functions of addressing and grouping. • Up to 120 luminaires per control module. weight (kg) 0.03 Up/downloading of the emergency lighting test report and • Provides a variety of feedback from each fixture including luminaire rated supply voltage mains adapter 230-240 v firmware via USB or Ethernet. status, LED health, battery health and more. dali luminaire diagnostics • Ability to add sensors. mains frequency mains adapter 50 / 60 hz • For small and medium emergency lighting systems with up • Provides a centralised location to allow you to control each individual diagnostics reported power 5w to 120 DALI emergency lighting units (60 for each DALI line). luminaire, reducing the cost of maintenance. communication fault yes • 2 addresses for external status controls. Ambient temperature 0....+50c • Interoperability offered allows use of products from a variety of manufacturers. battery fault yes max output current, dali 240 ma • Individual labeling of groups and devices. lamp fault yes type of protection ip20 • Calendar-controlled function and duration test. charger fault yes • Interconnection of up to 25 panels for bigger installations key benefits of dali possible. • Control Panel provides the end user with increased control and visibility. • OPEN PROTOCOL modules- customer flexibility. • An Ethernet backbone provides greater flexibility for increased distances in the system design and layout. • Remote access and monitoring is now easier via the Internet • CAD package floor plan integration with Ventilux CP. DALI CONTROLLER • Email reporting to key personnel with Ventilux CP. system mode dali controller • Testing can be programmed for non-working hours hence less disruption to work environment. part number vent / dali / cp • Allows up to 120 luminaires to run up to 300 meters using standard mains 1.5mm cable. 2 weight (kg) 1 • Ethernet bus can run up to 2000 meters using fiber cable. rated supply voltage mains adapter 230-240 v • Mid term cost savings on maintenance costs for an installation over conventional testing. mains frequency mains adapter 50 / 60 hz rated supply voltage 24-48 v dc Dali SYSTEM wiring schematic power 10w number of dali. circuits 2 current consumption of each dali line 2 ma Ambient temperature ta 0....+50c Emergency Emergency DALI DALI Emergency Emergency Luminaire Luminaire PSU PSU Luminaire Luminaire touchscreen size 7” touchscreen pixel 800 x 480 interface usb. ethernet dimensions l x w x h 200 x 150 x 20mm distance between mounting holes (d) 155mm MAINS FEED 24-48 V DC + max output current, dali 240 ma Permenant Live (Pl) DALI COMMUNICATION 10 VA - Earth (E) DALI A type of protection ip20 Neutral (N) DALI DALI B 12 CONTROLLER 13
dali NE TCOM5 systems systems NETCOM 5XP addressable testing SYSTEM N5XP CONTROL panel N5XP Control module overview overview overview netcom 5 xp system characteristics The N5XP system is based on the use of intelligent nodes built into position info The N5XP Control Panel (CP) is a PC-based software application The Control Module is the interface between the individual each emergency luminaire. It is a new approach to automatic testing of that controls, tests, and monitors the entire emergency lighting nodes and the Control Panel. The Control Module contains a max number of control modules 100 emergency lighting installations. Compatible with both self contained installation. The N5XP Control Panel communicates with the N5XP CAN Controller to communicate with the nodes and a CAN/ and central battery systems, it has become one of the market leaders in max luminaires per control module 253 Control Modules over an Ethernet network. Ethernet gateway that allows it to communicate with the Control the field of automated testing of emergency lighting installations. Each max luminaires per n5xp system 25,300 Panel and other Control Modules via an Ethernet network. intelligent luminaire has at its core, a stand-alone intelligent testing A maximum of 253 Control Modules can be connected to the The Control Module polls the nodes for status information, max cable distance from last luminaire to control module 1 kilometer module (referred to as the “node”), which tests the functionality of the N5XP Control Panel. The N5XP Control Panel software can be conducts tests on the nodes, and records the results from luminaire before reporting back to a central control panel via a localised max cable distance from control module to central hub 2 kilometers installed on any standard Microsoft Windows Operating System. the tests. A maximum of 100 nodes can be connected to control module. The node communicates with the control module via Windows 7 and above is the recommended platform. each Control Module. Standard Ethernet hubs are used to a proprietary CAN (Controller Area Network) protocol and the control interconnect the Control Modules to the Control Panel. module communicates to the control panel via industry standard n5xp luminaire diagnostics It is recommended that a dedicated PC is used for the N5XP ETHERNET. The testing system functions on an ethernet backbone and can application. With the latest interactive graphics program, the user SPECIFICATION diagnostics reported be easily integrated into an existing Local Area Network (LAN). The nodes can interface with an AUTO-CAD floor plan to establish the health test and measure the status of each luminaire and report back to Control communication fault yes of their emergency lighting installation. Site configurations are • No. of Nodes 100 Modules, which in turn report back to a central Control Panel over an easily uploaded and downloaded, allowing ease of site set up/ • Input Voltage 230V +/–10% 50/60 Hz battery fault yes Ethernet network. commissioning and troubleshooting. • Monitors lamp fault yes • Power On Green LED key benefits of netcom 5 xp charger fault yes The default N5XP system tests the emergency installation, daily, • Status Flashing Amber LED monthly and annually in accordance with current EN50172 • Isolated Amber LED • A PC based Control Panel provides the end user with increased control and visibility. legislation. A custom test regime is also available for user settings. • In Test Green LED With the options for EMAIL and SMS texting reporting, single • Comms Fault Red LED • An Ethernet backbone provides greater flexibility for increased distances in the system design and layout. or multi users, AUTO-CAD graphics package – the N5XP testing • Node Fault Red LED • Remote access and monitoring is now easier via the Internet. systems offers a cutting edge product, and peace of mind to the • Degree of Protection IP40 • Mutli-user access via the internet and intranet. client. • Overall Dimensions (mm) 215mm x 150mm x 70mm • CAD package floor plan integration. • Power rating 16 VA • Data cable CAN side - Belden 8719,9316,1030A • Alarm setting and reporting to key personnel. • Ethernet side industry standard CAT 5/CAT 6 cable • Testing can be programmed for non-working hours hence less disruption to work environment. • Cable Entry 3 x 20 mm Conduit Entries • Allows both CBU and Self-contained luminaires on the one system. on the bottom of the module • Weight 1.3 kg • Can be integrated into most mains and emergency luminaires, not just Ventilux luminaires. • Standards EN55015; EN61000; EN50082-2 • Global support from a Dublin based design centre. • Environment 0ºC to 30ºC Temperature Range: Up to 80% Relative Humidity • Housing construction White Powder Coated Sheet Steel n5xp SYSTEM network diagram NETCOM 5 XP CHANNELS CH1 CH2 CH3 CH n n5xp control panel n5xp control module NODE 100 NODE 100 NODE 100 NODE 100 System mode Part number System mode Part number n5xp testing system - control panel n5/cp n5xp testing system - control module n5xp/cm100 CAN BUS (MAX=1KM) CAN BUS (MAX=1KM) CAN BUS (MAX=1KM) Please note * The software should be installed on an IBM compatible PC with Please note * Each Control Module has the following Light Emitting Diodes CAN BUS (MAX=1KM) NODE 2 NODE 2 NODE 2 NODE 2 the following minimum system requirements: (LEDs) mounted on the exterior housing which are referred to as Control Module Status Indicators: Intel Core i5 Processor Power: Green - indicates that the regulated power is present NODE 1 Quad core NODE 1 NODE 1 NODE 1 Status: Flashing Green - indicates that the module is running correctly 4GB RAM DDR4 SDRAM Isolated: Yellow - indicates that one or more nodes are isolated. 500 GB Hard Drive, SATA 6Gb/s @ 7200rpm Can Can Can Can In Test: Yellow - indicates that one or more nodes are in emergency test or Controller Controller Controller Controller VGA,DVI graphics card commissioning Can/Ethernet Can/Ethernet Can/Ethernet Can/Ethernet 10/100 Base – T Ethernet Card Comms Fault: Red - indicates there is a fault with the CAN communications. Control Control gateway Control gateway Control gateway gateway Module Module Module Module 19” VGA LCD Monitor Node Fault: Red - indicates that there is a fault with one or more nodes. Ethernet - 10/100 Ethernet - 10/100 BaseT (max = 80M) Keyboard and Mouse BaseT (max = 80M) 14 Repeater Panel Ethernet (max = 2Km) Hub Control Panel 15 Hub
CENTRAL BATTERY SYSTEMS BAT TERY BA W OVERVIEW C AR ’S R systems systems EX A N The Ventilux Emergency Lighting (VES) series of Static Inverters are designed specifically for the TE T N YT most challenging of emergency lighting applications and are fully in compliance with EN50171, DS O EN50272-2, BS5266, IS3217 and ICEL1009. Providing capacity up to 160kVA, the Ventilux range of TH 5 Inverters is designed to provide a Static Inverter with all the flexibility and adaptability you need for E YE BA A the modern built environment. The Static Inverters are renowned for consistent reliability, ease of TT RS installation and maintenance. With options for either no break in supply, or transfer times less than ER Y 0.5s, the Ventilux Static Inverter range have solutions available for all with a wide choice of power ratings, accessories and Automatic Testing Solutions. With multiple ways to control lights within an application, the below descriptions and drawings show the various ways the lighting load may be features controlled. • MODBUS / PROFIBUS / LONBUS / SNMP/BACnet compatible Maintained output • Indicators to alert battery problems internal bypass • Individual voltage regulation through the equalizing process Static inverters provide continuous • Avoids overcharging and undercharging power to the emergency luminaires • Increased battery capacity and battery life expectancy during normal operation and during • Software provided power failure. rectifier battery analysis care system (bacs) inverter static switch OVERVIEW BACS is the most advanced product of its kind on the market today. Switch maintained An Ethernet integrated battery monitoring and management system, local switch BACS uses web management technology to monitor the temperature, internal resistance and voltage of every single battery in a given system. • During normal operation emergency central lights switch maintained mfr In an Emergency Lighting critical standby application, the battery is by • Emergency lights operate during and large an integral part of the system, and can also be an unpredictable mains failure Emergency luminaires element of the design. Battery condition can be invisible and not • Some lighting circuits left as determined from its appearance, making early diagnosis hard, maintained especially if problems have been experienced in transit, storage, • Emergency lights operate if local installation, poor site conditions or misuse, causing failure of switch is OFF during mains failure incoming Distribution board mains just one cell which can lead to open-circuit of a complete battery. non-maintained output The analysis part is the continuous checking of the internal resistance, temperature and voltage of every single battery block. The internal bypass care part is an equalization process that corrects the charging voltage for each battery block, as well as constant monitoring and controlling. In addition, it can manage environmental measurements such as temperature, humidity etc., as well as Static inverter output and emergency the Static Inverter system. luminaires are off during normal operation. During power failure the BACS effectively mitigates the possibility of overcharging the batteries, helping to prevent gassing and drying, as well as Static Inverter output is activated and alleviating the possibility of undercharging, preventing sulfation. Through the equalization process, the batteries are kept at an the luminaires turn on to illuminate output optimal charging voltage and therefore, in an optimal state of health. By managing the batteries charging voltages, BACS vastly the exit routes. rectifier static contractor improves the durability and reliability of the system. The web browser interface of the system is designed for easy configuration, inverter switch displaying all system values and events and alarms through a flexible event manager. The BACS WebManager acts as the central control unit by gathering, evaluating and storing all information on its internal flash memory. This can log all system data for a duration of at least 6 months up to 3 years dependent on the size of the system. phase failure monitoring l1 All data can be downloaded and archived over an ethernet network in order to free-up storage capacity for further data logging and analysis using the BACS Viewer software or other graphical programmes. Ventilux’s BACS system monitors key battery parameters • During normal operation emergency l2 and sets thresholds, therefore allowing advanced warnings, via audio, video and network messages, of a system event that requires lights non-maintained incoming attention. • Emergency lights operate during mains l3 mains failure • Emergency lights operate if any other Emergency luminaires EXTENDED BATTERY LIFE incoming phase fails The service life of a battery string depends on the weakest cell of the weakest battery in a string. The BACS equalising process Distribution board allows each of the batteries within a string to be maintained at Charge End Voltage rch arge optimal voltage levels, eliminating the ill effects of improper ove charging. The constant care provided by the equalising process e sub-circuit monitoring has been shown to increase service life by more than 30%. undercharg battery 3 • During normal operation emergency Battery 1 is ideal. lights non-maintained. battery 1 • Emergency lights operate during Battery 2 has low impedance which results in under mains failure battery 2 voltage condition and so this battery is boosted by BACS. • Emergency lights operate if any Emergency luminaires • sub-circuit breaker on non-emergency Battery 3 has high impedance which results in over voltage so lighting trips the battery is prevented from over charging by BACS. incoming 16 mains Distribution board 17
ECOLUX SERIES - 1/1 VES-mod SERIES ORDER CODES ORDER CODES features features systems systems model VA / W model KVA / KW VES-1005XA 500 / 400 • 3KVA Power Cabinet, built up of 500VA Power Modules. • 24kVA Power Cabinet, built up of 4kVA Power Modules. VES-MOD 4 4 / 3.6 VES-1012XA 1250 / 1000 • 1/1 Configuration via display. • 1/1 & 3/1 Configuration via display. VES-MOD 8 8 / 7.2 • Systems and battery Test Function. • Hot-Swap Power Module. VES-1030XA 3000 / 2400 VES-MOD 12 12 / 10.8 • True sinewave & PWM microprocessor controlled • True Sinewave Output. VES-MOD 16 16 / 14.4 technology. • Front access for all maintenance and repair. • Recharged batteries up to 80% within 12 hours. • Output configurable to 3 modes of operation VES-MOD 20 20 / 18 • LCD user information panel providing accurate, detailed • (Changeover/ Inverter/ Non-Maintained) VES-MOD 24 24 / 21.6 information about load, batteries, system diagnostics and • No break Load Transfer for use with Discharge Lamps. audible alarm. • Deep Discharge Protection. • Fast changeover to battery mode. • Reverse Battery Polarity Protection. • Built in Distribution (6 Circuit as Standard). • Each module automatically shares the input and output • RS232, and dry contacts for communication and remote current. monitoring. • All inverter modules share the same battery. • TCPIP / KNX / Netcom 5XP options supported. • Battery Short Circuit Protection. • Reduced mean time to repair to modular design. • Battery discharge management, auto-transfer between floating and equal charging, temperature compensation. • Multiple communication options RS232, RS485, drycontacts, TCI/IP adapter for local and remote communication. INPUTt ves ves ves ves ves ves Nominal Voltage 230 VAC ( 1Ph + N + PE ) model mod 4 mod 8 mod 12 mod 16 mod 20 mod 24 Voltage Range 184 V - 285 V Power rating kVA / kW 4 /3.6 8 / 7.2 12 / 10.8 16 / 14.4 20 / 18 24 / 21.6 Frequency Range 50 Hz ± 5% output output Nominal Voltage 220 / 230 / 240 Vac (1Ph + N + PE) Nominal Voltage 230 Vac AC Voltage Regulation ±1% AC Voltage Regulation ±3% Frequency Range ±4%, (±0.2% battery supply) Frequency Range Power Factor 0.9 ±1% Power Factor 0.8 Crest Factor 3:1 Crest Factor 3:1 Harmonic Distribution
VES-300dsp series 3/3 BSI KITEMARKED EXTERNAL MAINTENANCE BY-PASS SWITCH ORDER CODES Control (If external contactor systems OVERVIEW systems features model KVA / KW fitted). The External Range of Maintenance bypass Switches are available in 100A VES-310 dsp 10 / 9 • 160kVA Power Cabinet, built up of • Deep Discharge Protection. versions. VES-320 dsp 20 /18 10kVA Power Modules. • External Test Facility included. The BYPMBB11-100 is configured for 1 phase input and 1 phase output. • Unique inverter design to suit The BYPMBB33-100 is configured for 3 phase input and 3 phase output. • 3/3 Configuration via display. VES-330 dsp 30 / 27 high inrush lighting loads. The BYPMBB range is provided with the following features: • Recharges batteries up to 80% VES-340 dsp 40 / 36 • User selectable Inverter or • Electronic Interlock to Static Inverter within 12 hours. • Make Before Break Bypass Switch VES-360 dsp 60 / 54 • True Sinewave output & PWM Changeover Mode • UK engineers socket with CB protection VES-380 dsp 80 / 72 microprocessor controlled • DC short circuit protection • Safety cover for protection of miss-use VES-3100 dsp 100 / 90 technology. • LCD panel providing accurate • Inspection cover- allowing easy access for measurements to be completed. VES-3120 dsp 120 / 108 • Front access for all maintenance detailed information about • Mounting holes for easy installation. and repair. load, batteries and inverter with VES-3160 dsp 160 / 144 • FAR Controls including 48Vdc advanced diagnostics. VCOM/230V CHANGE OVER MODULE supply for Fire Alarm Panel. • RS232 and dry contacts for • Selectable Non-Maintained/ communication and remote OVERVIEW Maintained Mode with External monitoring. The Ventilux VCOM Static Inverter Change Over Module allows for change over from a VES VES VES VES VES VES VES VES VES switched mains supply to a static inverter emergency supply in the event of a mains failure. model 310 320 330 340 360 380 3100 3120 3160 Pre-programmed with a 500 mili-second delay the module can also be used with dimming DSP DSP DSP DSP DSP DSP DSP DSP DSP systems such as DALI and ensures that the high frequency ballast has been reset prior to Power rating kVA / kW 10 / 9 20 / 18 30 / 27 40 / 36 60 / 54 80 / 72 100 / 90 120 / 108 160 / 144 supplying static inverter power ensuring full illuminance during the emergency period. Rated to switch 480V, the VCOM is easy to use and install. The module can be used either within a input luminaire for individual luminaire control or mounted in a remote enclosure to control and Nominal Voltage 380 / 400 / 415 VAC (3PH + N + PE) switch an entire circuit load up to 1250VA. The module is also supplied with an optional Voltage Range 115% blue LED indicator which indicates when the static inverter supply has been switched in an Power Factor 0.99 @ Full load emergency condition. This blue LED indicator can be used as an additional safety indicator Harmonic Distortion
Types of escape route luminaire’s recessed Overview Considerations Recessed type fittings are one of the most • Ceiling cut out size. common escape route luminaires which • Ceiling void size. are a usually a single LED lamp head and a “Remote pack” which is inserted through a hole cut into a false ceiling or ceiling void. R Surface Surface mount mount Overview Considerations Surface mounted fittings are enclosures or • Mounting holes positions housings containing all the necessary luminaire i.e besa box. control gear internally, mounting directly • Cable entry points. to the ceiling, besa box or conduit pipe. SM bulkhead Overview Considerations Very similar in application and design to • Diffuser type. surface mount luminaires, they generally • Cable entry points. have a larger form factor and lumen output. Bulkheads distinguish themselves by having LED’S covered by a diffuser to better help BH light dispersal. Examples of common diffuser types are prismatic, fresnel and opal. Twin spot Overview Considerations A twin spot is a dual lamp luminaire, usually • Lamp type e.g LED, halogen led, halogen or tungsten filament. A common or tungsten filament. design characteristic of a twin spot is the ability • IP Rating. ESCAPE ROUTE LUMINAIRES to independently rotate and angle each of the lamp heads making it ideal for achieving efficient TS light spread in large open area applications. R OPTILENS P-26 SM OPTILENS SURFACE MOUNT P-27 R HALO P-28 R HALO IP65 P-29 R OPTIC RECESSED P-30 SM OPTIC SURFACE MOUNT P-31 Spacing tables for escape route luminaire’s SM EYECON P-32 R DELTA P-33 BH VISOR 120 P-34 BH WEATHERPROOF P-35 MOUNTING HEIGHT DISTANCE WALL TO LUMINAIRE DISTANCE LUMINAIRE TO LUMINAIRE R HI-LITE P-36 BH SKYLUX 9W HIGH BAY P-37 TS SCOUT LED P-38 TS I-LUX P-39 TS COMPACT TWIN LUX LED P-40 TS COMPACT TWIN LUX HALOGEN P-41 TS WEATHERPROOF TWIN LAMP LED IP67 P-42 TS WEATHERPROOF TWIN LAMP HALOGEN P-43 TS ETS IP65 TWINSPOT LED P-44 Overview Overview Overview BH SIRIUS P-45 BH NOVA LED RANGE P-46 The mounting height of the luminaire The distance from the luminaire The distance from the luminaire BH APOLLO IP65 P-47 from the ground to the ceiling. This to the nearest wall. to the next luminaire. R EVOLUX 3W P-48 will also factor into the distance of the light spread of the luminaire. All BH VISOR IP65 P-48 luminaires have an optimum mounting R EVOLUX 5W P-49 height which will allow it to achieve R VEGA P-49 its greatest light dispersion distance. CONVERSIONS SERVICE P-50 22 23
OPTILENS OPTILENS SURFACE MOUNT 24 25
ESCAPE ROUTE LIGHTING ESCAPE ROUTE LIGHTING OPTILENS OPTILENS surface mount overview DETAIL A overview The OptiLens utilises the latest lens development to provide The OptiLens Surface mount utilises the latest lens market leading uniform light distribution for both escape development to provide market leading uniform light route and open area emergency lighting applications, distribution for both escape route and open area emergency reducing the number of required emergency luminaires and lighting applications, reducing the number of required radically reducing the overall electrical power consumption. emergency luminaires and radically reducing the overall Supplied with both the escape route lens (asymmetrical light electrical power consumption. Supplied with both the escape pattern) and open plan lens (symmetrical light pattern) as route lens (asymmetrical light pattern) and open plan lens standard, the OptiLens offers the client ease of order DETAIL B (symmetrical light pattern) as standard, the OptiLens Surface processing and on site installation. Mount is a discreet and aesthetically pleasing fitting. SPECIFICATION SPECIFICATION • Suitable for recessed ceiling mounting. • Small discreet surface mounted luminaire. • Suitable for temp range – 0°C to 30°C. • Easy to install and maintain. • 3 way shrouded plug/socket mains connection. FEATURES FINISHES • First fix fitting. • 220mm ceiling void compatible. IP RATING ip40 MATERIAL FINISH • Supplied with both escape route & open plan lens for • Ceiling cutout - 38mm (Standard Self-Contained). FINISHES FEATURES polycarbonate WHITE flexibility on site during installation. PLASTIC RAL 9016 • Ceiling cutout - 50mm (N5XP/ DALI/ Self Test Versions). MATERIAL FINISH IP RATING ip20 polycarbonate BLACK • Dimensions of self contained remote pack – 30mm dia x Plastic RAL 9017 ABS WHITE 480mm (Other variants may differ). PLASTIC RAL 9016 • Supplied with both asymmetrical and symmetrical lens. ABS BLACK spacing table: ESCAPE ROUTE product code optilens sm: olnm3/led3w/sm Plastic RAL 9017 • Detail A- Standard Self Contained dimension. MOUNTING HEIGHT distance WALL TO LUMINAIRE DISTANCE LUMINAIRE TO system operation wattage lumens warranty (METERS) (METERS) LUMINAIRE (METERS) • Detail B- N5XP, DALI & SelfTest dimensions. spacing table: ESCAPE ROUTE Self Contained ... n-m 3w 120 6 yrs 2 5.2 12.2 • Remotely located charge LED, up to 32 metres available MOUNTING HEIGHT distance WALL TO LUMINAIRE DISTANCE LUMINAIRE TO Self test /at n-m 3w 120 3 yrs 2.5 5.2 14.0 (METERS) (METERS) LUMINAIRE (METERS) on request for this fitting, for Hospitals and Nursing Home DALI /dali n-m 3w 120 3 yrs 3 2..4 14.8 2 6.2 13.8 applications. Netcom 5 /n5xp n-m 3w 120 6 yrs 4 1.2 7.5 2.5 7.1 16.1 Central Battery /cbs 230v slave 3w 120 3 yrs 6 - 1.0 3 7.7 18.1 4 4.9 21.4 spacing table: OPEN PLAN 6 1.7 10.8 MOUNTING HEIGHT distance WALL TO LUMINAIRE DISTANCE LUMINAIRE TO (METERS) (METERS) LUMINAIRE (METERS) product code optilens: olnm3/led3W spacing table: OPEN PLAN 2 2.7 7.1 MOUNTING HEIGHT distance WALL TO LUMINAIRE DISTANCE LUMINAIRE TO 2.5 2.9 7.4 system operation wattage lumens warranty (METERS) (METERS) LUMINAIRE (METERS) 3 2.9 7.7 Self Contained ... n-m 3w 180 6 yrs 2 3.3 9.7 4 - 8.3 Self test /at n-m 3w 180 3 yrs 2.5 3.4 10.1 6 - - DALI /dali n-m 3w 180 3 yrs 3 3.5 10.3 Netcom 5 /n5xp n-m 3w 180 6 yrs 4 3.7 11.o Central Battery /cbs 230v slave 3w 180 3 yrs 6 - 12.2 26 27
ESCAPE ROUTE LIGHTING ESCAPE ROUTE LIGHTING halo halo ip65 overview DETAIL A overview The HALO 3 WATT is a discreet, recessed fitting which is The HALO IP65 3 WATT is a discreet, recessed fitting which is specifically designed to meet the needs of consultants, specifically designed for high IP rated environments to meet contractors and end-users. Purpose designed for interior use, the needs of consultants, contractors and end-users. the HALO 3 WATT luminaire is designed to fit into a hole of Purpose designed for exterior use, the HALO 3 WATT IP65 38mm, and comes in two parts, giving the installer more luminaire is designed to fit into a 44mm cut out and comes flexibility and ease of installation. Designed for indoor in two parts for ease of installation. Designed for exterior installation in a range of public locations. Incorporating the installation in a range of public locations the HALO IP65 3 latest CREE LED technology, the HALO 3 WATT offers the WATT is an ideal cost effective solution where the emphasis client long term operational and maintenance cost savings. is on discreet and aesthetic appearance. Incorporating the latest CREE LED technology, the HALO IP65 3 WATT offers SPECIFICATION the client long term operational and maintenance cost DETAIL B savings. • Suitable for ceiling mounting. SPECIFICATION • Ceiling cutout - 38mm (Standard Self-Contained). • Ceiling cutout - 65mm (N5XP/ DALI/ Self Test Versions). FEATURES FINISHES • Remote pack dimensions - 35mm dia X 450mm. • 220mm ceiling void compatible. IP RATING ip65 • Ceiling cutout - 44mm. • 3 way shrouded plug/socket mains connection. MATERIAL FINISH • 220mm ceiling void compatible. • Dimensions of lamp head - 45mm dia. ABS WHITE PLASTIC RAL 9016 • Dimensions of Lamp head - 52mm dia. • Dimensions of remote pack - 35mm dia x 450mm. ABS BLACK • Remotely located charge LED, up to 32 metres available on Plastic RAL 9017 request for Hospital and Nursing Home applications. FINISHES FEATURES spacing table product code: HANM3/LED/3W/IP65 MATERIAL FINISH IP RATING ip40 MOUNTING HEIGHT distance WALL TO LUMINAIRE DISTANCE LUMINAIRE TO system operation wattage lumens warranty (METERS) (METERS) LUMINAIRE (METERS) painted WHITE Self Contained ... n-m 3W 180 6 YRS 2 3.1 7.2 aluminium RAL 9016 Self test /at n-m 3W 180 3 YRS 2.5 3.5 8.3 painted BLACK aluminium RAL 9017 DALI /dali n-m 3W 180 3 YRS 3 3.6 9.1 Netcom 5 /n5xp n-m 3W 180 6 YRS 4 3.7 10 6 3.1 10.5 Central Battery /cbs 230v slave - 180 3 yrs product code: HANM3/LED3W spacing table MOUNTING HEIGHT distance WALL TO LUMINAIRE DISTANCE LUMINAIRE TO system operation wattage lumens warranty (METERS) (METERS) LUMINAIRE (METERS) Self Contained ... n-m 3w 180 6 yrs 2 3.0 6.9 Self test /at n-m 3w 180 3 yrs 2.5 3.2 7.9 DALI /dali n-m 3w 180 3 yrs 3 3.3 8.6 Netcom 5 /n5xp n-m 3w 180 6 yrs 4 3.3 9.2 Central Battery /cbs 230v slave - 180 3 yrs 6 2.2 9.3 28 29
ESCAPE ROUTE LIGHTING ESCAPE ROUTE LIGHTING optic recessed OPTIC SURFACE MOUNT overview overview The OPTIC LED is specifically designed to offer a cohesive The OPTIC LED is specifically designed to offer a cohesive escape route and open plan emergency lighting solution escape route and open plan emergency lighting solution within a specific project, maximising emergency light within a specific project, maximising emergency light distribution and offering long term cost savings to the client. distribution and offering long term cost savings to the client. Designed to seamlessly integrate into the interior aesthetic Designed to seamlessly integrate into the interior aesthetic of prestigious modern developments, and produced from the of prestigious modern developments and produced from the highest quality materials, the OPTIC LED range will appeal to highest quality materials, the OPTIC LED range will appeal to architects and consultants alike who require a flexible, innovative architects and consultants alike who require a flexible, innovative and discreet approach to emergency lighting. and discreet approach to emergency lighting. OPTIC available as a Recessed or Surface Mounted luminaire see below codes. SPECIFICATION Specification • Remote pack dimensions - 65mm dia x 700mm. • Attractive white powder coated sheet steel housing • Ceiling cutout - 85mm. and flame retardant ABS plastic lamp head designed to FINISHES FEATURES FEATURES FINISHES • 220mm ceiling void compatible. optimise light distribution for unique escape route and open MATERIAL FINISH IP RATING IP20 IP RATING IP20 • Remotely located charge LED, up to 32 metres MATERIAL FINISH plan applications. WHITE available on request for this fitting, for Hospitals ABS PLASTIC RAL 9016 ABS PLASTIC HEAD/ WHITE • 20mm conduit entries at each end of housing and BESA box STEEL HOUSING RAL 9016 and Nursing Home applications. BLACK entry in rear ABS Plastic ABS Plastic HEAD/ BLACK RAL 9017 STEEL HOUSING RAL 9017 • Maximum dimensions 200mm L x 200mm D x 70mm H. product code: OPNM3/LED/ES (ESCAPE ROUTE) spacing spacing table: table: ESCAPE ESCAPE ROUTE ROUTE spacing spacing table: table: ESCAPE ESCAPE ROUTE ROUTE product code: OPNM3/LED/ES/SM (ESCAPE ROUTE) OPNM3/LED/OP (OPEN PLAN) MOUNTING HEIGHT MOUNTING HEIGHT distance WALL TO LUMINAIRE distance WALL TO LUMINAIRE DISTANCE LUMINAIRE TO DISTANCE LUMINAIRE TO MOUNTING HEIGHT MOUNTING HEIGHT distance WALL TO LUMINAIRE distance WALL TO LUMINAIRE DISTANCE LUMINAIRE TO DISTANCE LUMINAIRE TO OPNM3/LED/OP/SM (OPEN PLAN) (METERS) (METERS) LUMINAIRE (METERS) (METERS) (METERS) LUMINAIRE (METERS) (METERS) (METERS) LUMINAIRE (METERS) (METERS) (METERS) LUMINAIRE (METERS) system operation wattage lumens warranty system operation wattage lumens warranty 2 3.9 9.6 2 3.9 9.6 2 3.9 9.6 2 3.9 9.6 Self Contained ... n-m 3W 300 6 YRS Self Contained ... n-m 3W 300 6 YRS 2.5 4.2 10.4 2.5 4.2 10.4 2.5 4.2 10.4 2.5 4.2 10.4 Self test /at n-m 3W 300 3 YRS Self test /at n-m 3W 300 3 YRS 3 4.5 11.1 3 4.5 11.1 3 4.5 11.1 3 4.5 11.1 DALI /dali n-m 3W 300 3 YRS DALI /dali n-m 3W 300 3 YRS 4 4.9 12.4 4 4.9 12.4 4 4.9 12.4 4 4.9 12.4 Netcom 5 /n5xp n-m 3W 300 6 YRS Netcom 5 /n5xp n-m 3W 300 6 YRS 6 5.2 14.2 6 5.2 14.2 6 5.2 14.2 6 5.2 14.2 Central Battery /cbs 230v slave - 300 3 YRS Central Battery /cbs 230v slave - 300 3 YRS spacing table: OPEN PLAN spacing table: OPEN PLAN MOUNTING HEIGHT distance WALL TO LUMINAIRE DISTANCE LUMINAIRE TO MOUNTING HEIGHT distance WALL TO LUMINAIRE DISTANCE LUMINAIRE TO (METERS) (METERS) LUMINAIRE (METERS) (METERS) (METERS) LUMINAIRE (METERS) 2 3.7 8.6 2 3.7 8.6 2.5 4.1 9.8 2.5 4.1 9.8 3 4.4 10.9 3 4.4 10.9 4 4.7 12.2 4 4.7 12.2 6 5.1 13.3 6 5.1 13.3 21 30 31
ESCAPE ROUTE LIGHTING ESCAPE ROUTE LIGHTING eyecon delta overview overview The EYECON LED is specifically designed to offer a cohesive The DELTA 3 WATT is a discreet, recessed fitting which is surface mounted escape route and open plan emergency specifically designed to meet the needs of consultants, lighting solution within a specific project, maximising contractors and end-users. Purpose-designed for interior use, emergency light distribution and offering long term cost the DELTA 3 WATT luminaire is designed to fit into a cutout savings to the client. Designed to seamlessly integrate into hole of 44mm, and comes in two parts, giving the installer the interior aesthetic of prestigious modern developments more flexibility and ease of installation. and produced from the highest quality materials, the EYECON LED range will appeal to architects and consultants alike who SPECIFICATION require a flexible, innovative and discreet approach to emergency lighting. • Dimensions of battery housing -196mm x 33mm x 25mm. SPECIFICATION • Dimensions of module housing -196mm x 33mm x 25mm. • Ceiling cutout - 44mm. • Surface mount discreet interior escape route and open • 220mm ceiling void compatible. plan emergency luminaire for non-maintained self • Shrouded plug/socket DALI/mains connection. contained applications. FINISHES FEATURES FEATURES FINISHES • Designed to optimise light distribution for escape route MATERIAL FINISH IP RATING IP20 IP RATING IP20 MATERIAL FINISH and open plan applications. polycarbonate WHITE ABS WHITE PLASTIC RAL 9016 PLASTIC RAL 9016 • 20mm cable entry point on the rear of the product. polycarbonate BLACK ABS BLACK Plastic RAL 9017 PLASTIC RAL 9017 product code: EYNM3/LED spacing table spacing table: product code: DENM3/LED3W/ system operation wattage lumens warranty MOUNTING HEIGHT dISTANCE WALL TO LUMINAIRE DISTANCE LUMINAIRE TO MOUNTING HEIGHT dISTANCE WALL TO LUMINAIRE DISTANCE LUMINAIRE TO system operation wattage lumens warranty (METERS) (METERS) LUMINAIRE (METERS) (METERS) (METERS) LUMINAIRE (METERS) Self Contained ... n-m 1W 120 6 YRS Self test /at n-m 3W 150 3 YRS 2 2.8 6.7 2 3.1 6.6 Central Battery /cbs 230v slave - 120 3 YRS DALI /dali n-m 3W 150 3 YRS 2.5 2.9 7.5 2.5 3.1 7.2 3 3.0 8.0 3 3 7.4 4 2.9 8.5 4 2.7 7.6 6 1.0 8.1 6 - - 32 33
CO LD ESCAPE ROUTE LIGHTING RO ESCAPE ROUTE LIGHTING O M V ER SI O N AV A IL A BL E visor 120 weatherproof overview overview Designed for indoor and outdoor installations in a range The robust and durable design of the WEATHERPROOF (WP) of commercial and industrial locations, the compact VISOR LED 3 watt bulkhead luminaire, makes it ideal for a range of LED luminaire offers a high level of specification offering exterior and selected interior locations. Operators of leisure 120 lumens in emergency, ease of installation and excellent centers, car parks, sports facilities, factories and underground value for money. Ease of installation, provided by a hinged walkways will benefit from its tough, vandal resistant mounted gear tray and a choice of cable entries, as well as construction and ease of installation. Supplied as standard with a lens design which maximises light distribution, are key a vandal resistant polycarbonate body and a choice of opal or factors which make the VISOR LED one of the most exciting clear polycarbonate prismatic diffuser complete with vandal and popular luminaires available from Ventilux. resistant fixings, it makes the luminaire suitable for the most challenging locations. SPECIFICATION SPECIFICATION • Competitively priced, IP65 LED bulkhead. • Easy to install and maintain. FINISHES FEATURES FEATURES FINISHES • High powered LED bulkhead. IP RATING IP65 IP RATING IP65 • Slimline stylish appearance. MATERIAL FINISH MATERIAL FINISH • Vandal resistant design. TAMPER ABS WHITE PROTECTION PROOF ABS WHITE • Easy to install and maintain. PLASTIC RAL 9016 PLASTIC RAL 9016 • Supplied with 3X1 watt CREE LED Lamp. ABS BLACK ABS BLACK Plastic RAL 9017 PLASTIC RAL 9017 • Suitable for temp range - 20°C to 0°C (Coldroom version). product code: VINM3/LED/120 spacing table spacing table: WPNM3/LED3W product code weatherproof: wpnm3/led3w system operation wattage lumens warranty MOUNTING HEIGHT dISTANCE WALL TO LUMINAIRE DISTANCE LUMINAIRE TO MOUNTING HEIGHT distance WALL TO LUMINAIRE DISTANCE LUMINAIRE TO system operation wattage lumens warranty (METERS) (METERS) LUMINAIRE (METERS) (METERS) (METERS) LUMINAIRE (METERS) Self Contained ... n-m 1W 120 6 YRS Self Contained ... n-m/M 3W 300 6 YRS 2 2.3 7.1 2 3.5 9.2 Self test /At n-m 1W 120 3 YRS Self test /at N-m/M 3W 300 3 YRS 2.5 1.8 6.9 2..5 3.6 9.7 DALI /dali n-m 1W 120 3 YRS DALI /dali n-m 3W 300 3 YRS 3 1.4 6.3 3 3.7 10 Netcom 5 /n5xp n-m 1W 120 6 YRS Netcom 5 /n5xp N-m/M 3W 300 6 YRS 4 - 4.2 4 3.5 10.3 Central Battery /cbs 230v slave 1W 120 3 YRS Central Battery /cbs 230v slave - 300 3 yRS 6 - - 6 2.2 9.8 spacing table: WPM3/LED/3W/CR product code COLD-ROOM weatherproof: MOUNTING HEIGHT distance WALL TO LUMINAIRE DISTANCE LUMINAIRE TO wpm3/led/3w/CR (METERS) (METERS) LUMINAIRE (METERS) system operation wattage lumens warranty 2 3.3 8.4 Self Contained ... m 3W 240 6 YRS 2.5 2.8 9.1 Self test /at m 3W 240 3 YRS 3 2.9 9.1 DALI /dali m 3W 240 3 YRS 4 2.7 8.2 Netcom 5 /n5xp m 3W 240 6 YRS 6 0.2 7.1 Central Battery /cbs 230v slave - 300 3 yRS 34 35
e ir a ESCAPE ROUTE LIGHTING in ESCAPE ROUTE LIGHTING m lu a re a sk ri h g hi hi-lite skylux 9w HIGH BAY overview overview The HI-LITE 3 WATT is a discreet, recessed fitting which is Designed specifically for high ceiling commercial and specifically designed to illuminate fire call points, first aid points industrial applications, the compact SKYLUX 9 WATT LED etc to the required 5 lux vertical illumination. Purpose designed emergency luminaire offers a high level of specification, ease of for interior use, the HI-LITE 3 WATT luminaire is designed to fit installation and excellent value for money. Operators of leisure into a cut out hole of 45mm, and comes in two parts, giving the centers, car parks, sports facilities and high ceiling factories will installer more flexibility and ease of installation. A minimum of benefit from its tough, vandal resistant construction and ease a 5 lux wall wash is achieved from ceiling heights of up to 10 of installation. Offering 6 high powered 1.5 watt LEDs giving meters, making it the ideal fitting for illuminating: an impressive 900 lumens in emergency, this product offers a technically superior alternative to the conventional twin spots • Call points/Break glass units in high bay applications, offering an impressive 20 metre 1.0 lux • High risk areas spacing at a 10 metre ceiling height. • Disabled refuge points • Distribution boards SPECIFICATION SPECIFICATION • Flame Retardant ABS body FINISHES FEATURES FINISHES FEATURES • Tamper Proof Luminaire • Purposed designed 30 degree focused lens. MATERIAL FINISH IP RATING IP40 MATERIAL FINISH IP RATING IP65 • IP65 Rating • Adjustable gimbal to focus light on specific points of mounting TAMPER emphasis. ALUMINUM WHITE RAL heights up to 10 5 lux ABS WHITE PROTECTION PROOF 9016 PLASTIC RAL 9016 meters • Remote pack dimensions - 35mm dia x 450mm. BLACK RAL ABS BLACK ALUMINUM • Ceiling cutout - 45mm. 9017 PLASTIC RAL 9017 • 220mm ceiling void compatible. • Remotely located charge LED, up to 32 metres product code: spacing table: product code skylux: sknm3/led9w available on request for this fitting, for Hospital system operation wattage lumens warranty MOUNTING HEIGHT dISTANCE WALL TO LUMINAIRE DISTANCE LUMINAIRE TO system operation wattage lumens warranty (METERS) (METERS) LUMINAIRE (METERS) and Nursing Home applications. Self Contained ... n-m 3w 180 6 yrs Self Contained ... n-m 9W 900 6 YRS 6 6.7 22.4 Self test /at n-m 3w 180 3 yrs Self test /at n-m 9W 900 3 YRS 8 7.3 18.6 DALI /dali n-m 3w 180 3 yrs Netcom 5 /n5xp n-m 9W 900 6 YRS 10 6.7 20.4 Netcom 5 /n5xp n-m 3w 180 6 yrs Central Battery /cbs 230v slave 9W 900 3 YRS 12 6.1 20.4 Central Battery /cbs 230v slave - 180 3 yrs 14 4.7 19.1 24 36 25 37