Self-powered intelligent Thermostatic Radiator Valve (iTRV) - MVA-005 With local set point
←
→
Page content transcription
If your browser does not render page correctly, please read the page content below
MVA-005 Self-powered intelligent Thermostatic Radiator Valve (iTRV) battery-free, wireless, maintenance-free Ne W ! it h lo c a l set point W adjustment Energy harvesting
Product Self-powered intelligent Thermostatic Radiator Valve (iTRV) MVA 005 Functions • Local +/- setpoint adjustment on the drive. • The integrated thermogenerator converts heat into electrical energy that powers the actuator. • Works completely maintenance-free 365 days a year. • Configurable via Remote Management/Commissioning (ReMan/ReCom). • Operation in valve position (%) or self-regulation (°C) • Adjustable radio communication interval • Transmission of the flow temperature • Stand-by operation for unheated rooms • Status feedback on energy management, radio quality, radio failure, motor status. * Summer mode max. Source: Metrological Data, German Weather Service min. Jan 13 Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec 13
Temperature difference in buildings 50 45 40 Radiator inlet temperature 35 30 Temperature in °C 25 20 15 Room temperature 10 5 0 00.00 02.00 04.00 06.00 08.00 10.00 12.00 14.00 16.00 18.00 20.00 22.00 Energy-budget 3,0 Excess energy: Energy will be stored for operation during 2,5 transition periods and summer period. 2,0 1,5 Output power 1,0 thermogenerator 0,5 Joule Power requirement iTRV operation 0 00.00 02.00 04.00 06.00 08.00 10.00 12.00 14.00 16.00 18.00 20.00 22.00 Charge level of internal energy storage More energy is generated than consumed. The excess energy charges the internal storage The excess energy stored during winter time is used to power the system through the warmer months. The system works continuously throughout the year. Jan 14 Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec 14
Application Individual room temperature control by wireless and battery-free sensors and iTRV Benefits & Features • Energy-savings! • Maintenance-free system, deploy and forget. The iTRV operates without batteries open-plan office 21 °C day temp. and wires! 16 °C night temp. • Retro-fit installation • On demand heating control for individual rooms. • Compatible with building automation systems through EnOcean radio standard. office 21 °C day 16 °C night
Compliant w h EN1 5232 it mance Energy perfor of bu ild in gs Exemplary installation Arb B Arb B Arb B Arb B eit tte eit tte eit tte eit tte a a a a et rie et rie et rie et rie oh n oh n oh n oh n ne ne ne ne Window Presence Room sensor iTRV sensor sensor Room controller Building Field-bus Gateway management (KNX, LON, BACnet, modBus…) Individual room temperature control in office space: each room is heated indiviually according to demand. kitchen 21°C comms room office office conference room lab 21 °C day 21 °C day 21 °C day 21°C constant temp. 16 °C night 16 °C night 16 °C night (24/7)
Technology Energy Harvesting with Thermogenerator Thermoelectric principle • Thermogenerator converts temperature difference between radiator intake and ambient air into electricity. • Energy Harvesting enables battery-free, maintenance-free and wireless operation by using radiator heat. • Perfect for wireless sensor and actuator equipment for building automation applications. Power Energy generator Thermo- Management storage Valve Gearbox control Motor Radio
MVA 005 Technical Details Technical details MVA 005: Valve type: M30 x 1,5 Adapters: availabe for standard valve bodies Ambient temperature, environment: 0 – 40 °C, max. 70% rH Inlet temperature max.: 75°C max. Temperature, transport and storage: –10 – +45 °C, max. 70% rH Calibration range: > 5 mm Operating range (0 – 100%): 2.5 mm typical Step width min.: 1%-steps (> 3 % change to last position) Travel speed: 0.95 mm/sec typical Force in normal operation: 100 N typical Radio interval, normal operation: Default: automatic or according to EEP A5-20-06 Radio interval after start-up: every 2 mins during 30 mins Ambient temperature: Effective temperature value in the nearfield of the drive. After 30 minutes approximated temperature value. Freeze protection: < 6 °C valve on 95 % (< 0 °C for setpoint setting = 0°C) Window-open detection: yes Radio failure: Internal controller with last setpoint tempera- ture °C transmitted, otherwise default = 21°C EnOcean EEP: A5-20-06 (valve position %, target temperature °C) EnOcean ReMan/ReCom: Yes, see datasheet Status and maintenance functions: Yes, see EEP Local adjustment: +/– 5 °C (+/– 5 relative at valve position) Temperature sensor accuracy: +/– 0,5 ºC Energy storage: Designed for 365 days operation. Energy production min.: 90 standard heating days flow > 40°C Frequency: 868.3 MHz Dimensions: 55 x 95 mm (Ø x T) Maximum radiated power: +1,4 dBm (EN 300220-2:V3.1.1) Receiver: Category 2 (EN 300 220-1 V3.1.1) Conformity: CE
Micropelt – a brand of EH4 GmbH Am Gansacker 10a D-79224 Umkirch, Germany pho: +49 (0)7665 93 21 83-0 e-mail: info@micropelt.com www.micropelt.com 02.2019