Operation Manual VITOWELL EASY P1 - VITOWELL EASY P1

Page created by Antonio Dominguez
 
CONTINUE READING
Operation
Manual

VITOWELL EASY P1
Instant Water Heater

VITOWELL EASY P1

                       117 mm
Parts Identification

       5                               1    11                        14

       6                                    12

                                            13

       7                                                              21
                            *          2
                        4
                                                                      17
       8
                                            15                        18
                                       3
       9                                    22                        19

                                            16

                                       4                              4

       10                              22                             20

1.     Front Cover                   12.    Thermostat
2.     LED Indicators                13.    Heater Tank
3.     Temperature Control Knob      14.    Terminal Block
4.     Stop Valve                    15.    Main PCB Board
5.     Rail Support / Wall Bracket   16.    Water Outlet Connection
6.     Handshower                    17.    TRIAC
7.     Adjustable Shower Holder      18.    Water Inlet Connection
8.     Slider Rail                   19.    Flow Sensor
9.     PVC Hose                      20.    Mesh Filter
10.    Soap Tray                     21.    LED Board
11.    Heater Base                   22.    Thermistor
Important Safety Information

     Products manufactured by us are            In times of lightning/thunder, switch
safe provided they are installed, used      off the electric supply to the instant
and maintained in good working order        water heater in advance to protect the
in accordance with our instructions and     instant water heater against possible
recommendations. Always refer to this       damage.
manual if you have any doubt.                   Metallic/chrome hose and conduc-
     The appliance must be earthed.         tive control valve shall not be used.
Improper grounding could cause              (Malaysia only)
electric shock.                             Note: When removing the instant water
     If any of the following conditions     heater from package, small amount of
occur, immediately switch off the mains     water may be found inside. This is
and contact the sales agent for repair.     normal as the unit is tested during
Never attempt to repair the unit            manufacturing process.
yourself.                                            Installation must be carried
 -If the heater begins to make an odd            out by a qualified personnel and
noise, smell or smoke.                           in compliance to the local
 -Water temperature can not be                   authority regulations.
controlled.                                          This instant water heater
 -If the instant water heater shows signs        must be permanently connected
of a distinct change in performance.             to the direct main current supply.
 -If found water leakage from inside.            The use of a plug and socket is
     The appliance is not intended for           not recommended.
use by person (including children) with               For the correct size of wire
reduced physical, sensory or mental              conductor corresponding to
capabilities, or lack of experience and          different electrical loading,
knowledge, unless they have been                 please refer to the Electrical
given supervision responsible for their          Loading Table.
safety.Children should be supervised at               This instant water heater
all times when using the unit to ensure          operates at a minimum water
that they do not play with the appliance.        flow rate of 2.0 L/min and
                                                 maximum working pressure of 6
User is advised to test and adjust               bars. For direct connection to the
the water temperature before                     water tank, the heater must have
showering.                                       a minimum distance of 1.0m
                                                 below the water tank.
                                                      This instant water heater will
                                                 not function if there is insufficient
                                                 water flow (min 2.0 L/min) to
                                                 trigger the flow switch.
                                                      The thermostat will automati-
                                                 cally cut off the power supply if it
                                                 has sensed an abnormal rise in
                                                 water outlet temperature.
Heater Unit Installation

                                                           *

                                                                        260 mm

                                                      *         *
                                                       137 mm
                                             Rubber                 Rubber
                                             Washe                  Washe
                                                      Screw A

   Select a suitable position in the          Insert the Shower Holder and Soap
bathroom.                                  Tray into the Slider Rail.
    Pull out the Temperature Control          Mount the Slider Rail to the Rail
Knob and then remove the Screw A at        Bracket.
the bottom of the unit.                       Remove the cap from the Rail
    Remove the Front Cover from the        Bracket and screw the Bracket to
bottom and then lift up the Front Cover.   marked position. Replace the cap.
    Mark 3 Screw points of the Heater
Base on the wall. (Refer * marking)
    The Instant Water Heater position
should be1.5m above the bathroom
floor.
    Mark 2 screw points of the Slider
Rail beside the heater. It is recom-
mended that the top of the portion is in
level with the top of Instant Water
Heater.
    Use 6mm diameter drill and make
the wall plug holes in depth of 34mm.
    Insert the wall plugs and mount the
Instant Water Heater firmly in position
with the screws provided.
Plumbing Procedure

  This Instant Water Heater is a           THE WATER INLET AND
  single point system and the            OUTLET MUST BE INSTALLED
  “Water Outlet” can only                CORRECTLY , OTHERWISE IT
  be fitted to the PVC Hose and           MAY CAUSE A DAMAGE TO
  Handshower set provided. NO            THE HEATING ELEMENT.
  CONTROL VALVE OR                         DO NOT APPLY PLUMBING
  FITTING CAN BE FITTED TO               CEMENT ON CONNECTION.
                                         WHENEVER NECESSARY, USE
  THE WATER OUTLET.
                                         ONLY THREAD OR SEALING
      Connect the Stop Valve to the
                                         TAPE.
  Water Inlet with washer. Use
  correct tools to tighten the
  connection and be careful not to
  over tighten and damage the
  plastic nut.
      Connect the incoming water
  piping to the Stop Valve (1/2”
  BSP). Make sure to put the Mesh
  Filter between Stop Valve and
  incoming water piping.
      If in any case, the Stop Valve
  is not used or omitted, make
  sure to put the Mesh Filter
  between the heater unit inlet pipe
  and incoming water pipe.
      Turn on the water mains to
  drain out all plumbing dirts, at the
  same time fill up the heater tank.
  THE HEATER TANK MUST BE
  FILLED UP WITH WATER
  BEFORE TURNING ON THE
  ELECTRICITY SUPPLY TO
  PREVENT ANY DRY BURNT
  DAMAGE TO THE HEATING
  ELEMENT.
      Connect the PVC Hose and
  Handshower to the outlet of the
  Instant Water Heater, be sure to
  put in the Washer.
      Hook the Handshower to the
  Sliding Rail Shower Holder and
  adjust to your ideal position.
      Check if any water leakage.
      Do not use white tape during
  piping installation.
Electrical Installation
                                                            B

                          Fuse Distributor Board                   A
         FUSE             Miniature Circuit Breaker (MCB)
                          Double PVC cable over 2.5mm²
       ON/OFF ON/OFF Double Pole Switch

                           Cable                                         Position
                                                                          At Off

  NOTE:
  Refer to Table 1. for
  electrical loading
  and correct size of
  wire conductor.

 BROWN           — LIVE (L)
 or RED
 BLUE or BLACK   — NEUTRAL (N)
 GREEN            — EARTH (    )            Position
 or GREEN/YELLOW                             At Off

PROCEDURE:

Insert the cable through ‘A’ for side
entry or ‘B’ for wall embedded cable by
cutting a hole through the source cord
rubber holder.                                              This appliance must be
Connect the cable to Terminal Block                         EARTHED. Improper grounding
and fully tighten them as follow                            could cause electrical shock.
BROWN or RED — LIVE (L)                                     Remember to SWITCH OFF at
BLUE or BLACK — NEUTRAL (N)                                 mains before carrying out any
GREEN/YELLOW — EARTH (                  )                   electrical work.
When replace back the Front Cover,                          Refer to the Electrical Loading
please take note the below procedure:                       Table for the correct cable size.
   To ensure the correct position, turn                     Use double coated flexible cable
the Temperature VR Knob insert to                           having nominal cross-sectional
OFF position as shown in Fig A. (at the                     area 2.5mm².
Heater Base)                                                Lead the power cable from the
   To install the Front Cover, turn the                     MCB to a “ON/OFF” double pole
Temperature Control Knob to OFF                             linked switch having a contact
position to align with the VR Knob                          separation of at least 3mm in all
connect the LED display cable from                          poles outside the bathroom, then
front cover to the Main Control PCB.                        lead a cable connected to
Clamp the cable to the correct position.                    Terminal block inside the unit.
CHECK IF THE WIRING CONNEC-
TION IS CORRECT and replace the
cover.
   Fix back the Screw A.
Electrical Loading Table

 Voltage    Power             Current     Minimum Conductor Size (csa)        On/Off    Fuse /
  (AC)       (kW)               (A)     mm²   Conduit Cable   Flexible Cable Switch (A) MCB (A)
 240~
50/60Hz    (Malaysia Modal)

 230~
50/60Hz

 220~
50/60Hz

  Test Run

    Turn on the water supply and Stop Valve, the water will flow through the
Handshower.
    Switch on the electrical supply.
Turn the Temperature Control Knob to ‘ON’, the Red Indicator light (Power)
will turn on, hot water will flow out within a few seconds. The more Temperature
Control Knob being turned in clockwise direction, the hotter the shower is.
     The shower might not be hot enought even at ‘MAX’ position if incoming water
supply from the mains is too cold or pressure water is too high. In this case, you
may adjust the Stop Valve to reduce the water inflow in order to get the desired
showering temperature.
     Switch OFF the electricity supply after shower.
Handshower Spray Action

This innovative adjustable
Handshower has 5 different spray
actions (STANDARD, SOOTHE,
JUMBO, MIX, MASSAGE). The
actions are described as above.
      Clean the Handshower Head
      holes by using the soft brush
      from time to time.
      Recommended once a week.
      Note: Take care not to
      damage the holes of the
      Handshower Head during
      cleaning.
Maintainance

                           FLOW REGULATOR
                         OPEN   CLOSE           FILTER UNIT
                                                CLEANING

              INTERNAL
              STRAINER

            BUILT-IN FILTER OPEN        CLOSE

               MESH FILTER

Read the section ‘IMPORTANT
SAFETY INFORMATION’ first.
     CLEANING PRECAUTION!
Do not use thinner, alcohol, petrol or
any other organic solution to clean the
set, use only a damp cloth with mild
detergent.
     CLEAN THE FILTER REGULARLY.
There are two filters located at the stop
valve, one is Mesh Filter (installed at
the incoming water supply), another
one is the built-in filter as shown.
     Clean the Mesh Filter regularly to
prevent blockage. Remove the built-in
filter by turn it anti-clockwise as shown .
Take out the Filter and flush it with
water to remove any trapped sendi-
ments.
Troubleshooting

Problem/Symptom            Cause                        Action/Cure
Electric Water     Interrupted power        Check the wire connection and main power
Heater fail to     supply.                  supply. If it still fail to operate, contact
operate, no power.                          Viessmann Customer Service Call Centre.
                    Electric Water Heater   Check other appliances are having same
                    malfunction.            phenomenal and contact local Electricity Supply
                                            Company. If it still fail to operate, contact
                                            Viessmann Customer Service Call Centre.
Water too hot.      Not enough water        Increase flow rate via water flow controler or 3
                    flowing through the     in 1 Stop valve.
                    shower.                 Blocked of shower head - clean or replace.

                    Blockage in water       Check if 3 in 1 stop valve are fully turns on.
                    supply.                 Cleaning Mesh Filter and Built In Filter.

                    Incoming water          Reduce the setting temperature via
                    temperature too high.   temperature adjuster.

Water hot after     Water temperature     Avoid shower with water output during that
close and reopen    higher than set       period. Let the water flow few seconds before
of 3 in 1 Stop      temperature when 3 in continue bathing.
Valve or Water      1 Stop Valve or Water
Tap.                Tap is OFF a while
                    and reopen again.

Water too cool or   Too much water flow.    Reduce flow rate via water flow controller or 3
cold.                                       in 1 Stop Valve.
                    Water pressure below    Check water supply from mains or tank fed. If
                    minimum required and    tank fed, replumb to mains water supply and
                    water heater not        check if the water pressure is enough. If mains
                    function.               fed, make sure that mains 3 in 1stop valve is
                                            fully turns on and that there are no other
                                            restrictions in the water supply while water
                                            heater is in use.
Troubleshooting

Problem/Symptom                     Cause                                               Action/Cure
 Electric Water   Incoming water                              Adjust the 3 in 1 Stop valve.
 Heater no power. flow too low.

                         Electrical malfunction               Contact Viessmann Customer Service
                         of Electric Water                    Call Centre.
                         Heater.
                         Safety Thermostat                    Safety Thermostat cut-out operated.
                         cut-out operated.                    Contact Viessmann Customer Service
                                                              Call Centre.
 Water flow too          3 in 1 Stop Valve                    Clean the filter.
 low.                    Filter/Mesh Filter
                         blocked.
                         3 in 1 Stop Valve not                Open 3 in 1 Stop Valve to desire flow
                         fully open.                          rate.
                         Water supply                          Check house water supply.
                         insufficent.

NOTES
It is advised all electrical maintenance/                  Heater failure other than detailed in the
repairs to the shower should be carried                    fault finding page, please contact
out by a suitably qualified person.                        Viessmann Customer Service Call
In the unlikely event of Electric Water                    Centre for advice.

 Wiring Diagram

               E     N               L

                                                                                           Led Board
                                                           Led Board

                                            Manual Reset
                                                               L1
                                            Thermal
                                            Cut-Out
                                            & Thermostat       T2
                                         TRIAC                  G
                                                                       Power ON/OFF
                                                               N1
                                                                       Temp. Control

                                                                         TR FS

                                                                                                 Inlet
                           Heater                                          Turbine Flow Switch
                                                                                                 Outlet
                                                                           Thermistor

                                              Manual Reset (90 C Thermostat)
                                              For Models rated 4.5kW and below,
                                              thermostat is manually resetable.
Electrical Specification

                                  3.3kW 230Va.c. 50/60Hz

                                  2

      Min. INLET WATER PRESSURE   0.1 Bar (10kPa)

     Max. INLET WATER PRESSURE    6 Bar (0.6MPa)

                                  210 x 343 x 87 mm

                                  1.6 Kg (No Pump)
#04-01/02
You can also read