NVR - IRWIN PROPERTY PLANNED UNIT DEVELOPMENT - REGULATING PATTERN BOOK - Rutherford County Government
←
→
Page content transcription
If your browser does not render page correctly, please read the page content below
NVR - IRWIN PROPERTY PLANNED UNIT DEVELOPMENT - REGULATING PATTERN BOOK - Submission Date: • December 15th, 2020 Revision Date: • January 28th, 2021 • March 25th, 2021 • July 13th, 2021 • August 6th, 2021 © Copyright 2021, PVE Engineering, LLC
Applicant Information Company Name: NVR, INC Attn: Davis Lamb Email: dlamb@nvrinc.com Mail Address: 302 Innovation Drive, Franklin TN, 37067 Suite 200 Engineer Information Company Name: PVE, LLC Attn: Grant Shiring Phone: (724)-444-1100 Email: Gshiring@pve-llc.com Mail Address: 2000 Georgetown Drive, Sewickley PA, 15143 Suite 101 Table of Contents • Cover Page (1) • Table of Contents / Applicant Information (2) • Regional Site Context (3) • Zoning Analysis (4) • Major Thoroughfare Plan (5) • Structural / Use Analysis (6) • Hydrological Analysis (7) • Existing Conditions / Survey (8-9) • Concept Plan / Development Standards (10-11) • Lot Type / Sidewalk Exhibit (12-13) • Phasing Exhibit (14-15) • Open Space Exhibit (16-17) • Architectural Characteristics (18-19) PROLOGUE TABLE OF CONTENTS 2.
Data Source: Google Maps Central Valley Rd US-231 1 Crusade R US-23 d N REGIONAL SITE CONTEXT Not to Scale • Address: 4871 Lebanon Pike Subject Property Murfreesboro • Parcel ID: 047-073.00-000 Boundary City Limits The subject property is situated within the County of Rutherford; North of the City of Murfreesboro, just outside the regulatory limits of the City. Specifically located along US-231, the 57.0 Acre site shall be subject to the most-recent regulations set forth by The Rutherford County Zoning Ordinance. The Planned Unit Development shall consist of 137 single-family dwellings, for a proposed gross density of 2.40 dwelling units per acre. PROLOGUE 3. PROJECT SYNOPSIS
Data Source: Rutherford County Public Information App & City of Murfressboro Public GIS Mapping MURFREESBORO MUNICIPAL LIMIT N ZONING ANALYSIS Not to Scale Rutherford County Zoning Classification Subject Property Boundary Murfreesboro Municipal Boundary City of Murfreesboro Zoning Classification PRD RS-10 Located just outside the Municipal Boundary of the City of Murfreesboro, the site is surrounded by predominately residential land uses / zoning classifications. The subject site area is currently classified as (RM) Medium Density Residential, which should create optimal conditions for the proposed PUD development and ensure minimal conflicts with existing character within the area. EXISTING CONDITIONS ZONING ANALYSIS 4.
Data Source: Rutherford County Public Information App N LONG-RANGE TRANSPORTATION PLAN Not to Scale Safety Improvement Two Lanes with Shoulders Subject Property Boundary Three Lanes Five Lanes EXISTING CONDITIONS 5. MAJOR THOROUGHFARE PLAN
Data Source: Rutherford County Public Information App 2 3 4 5 1 13 7 6 11 12 10 8 9 N STRUCTURAL / USE ANALYSIS Not to Scale Existing Building Use ID Symbol Adjoining Property and/or Structure (See table below) within 200’ of site Subject Property X Boundary Lot No. Existing Structures Identified Use 1. (3) Structures 6000 - Farm-Use 2. (4) Structures 6000 - Farm-Use 3. Unknown 6000 - Farm-Use 4. Unknown 9100 - Cemetery 5. Unknown 1000 - Res Assess 6. (1) Structure 1000 - Res Assess 7. (2) Structures 1000 - Res Assess 8. Unknown 6000 - Farm-Use 9. (1) Structure 7000 - Farm-Market 10. Unknown 1000 - Res Assess 11. (2) Structures 1000 - Res Assess 12. (2) Structures 1000 - Res Assess 13. Unknown 7000 - Farm-Market EXISTING CONDITIONS STRUCTURAL / USE ANALYSIS 6.
Data Source: Rutherford County Public Information App ZONE X N HYDROLOGICAL ANALYSIS Not to Scale Subject Property nuary 25, 2021 Boundary Flow Direction U P D N Current Flood Hazard Zone: Zone X (Area of Minimal Flood Hazard) The graphic above demonstrates that the site is located within (Zone X), or Area of Minimal Flood Hazard Zone. No portion of this development is situated within any areas of FEMA Floodplain. EXISTING CONDITIONS 7. HYDROLOGICAL ANALYSIS
75’ WIDE LEBANON PIKE UTILITY EASEMENT (US-231) APPROX. LOCATION OF SEWER FORCE MAIN (CONDITION UNKNOWN) 50’ WIDE ACCESS EASEMENT 20’ WIDE EASEMENT (Use Unknown) EXISTING OVERHEAD UTILITIES EXISTING OVERHEAD UTILITIES HARLEY WAY Existing Overhead Electrical Line Existing Underground Sanitary Line Existing Easement Total Site Area: Subject Property 57.01 Acres Boundary EXISTING CONDITIONS EXISTING CONDITIONS SURVEY 9.
SEE LANDSCAPE BUFFER NOTE TRAIL SYSTEM FUTURE ROAD ACTIVE OPEN CONNECTION ter SPACE m way 2 r t StoFacili SEE LANDSCAPE BUFFER NOTE FUTURE ROAD CONNECTION FUTURE ROAD ROAD 1 CONNECTION C ROAD 1 C Stormwater ACTIVE OPEN C ACTIVE OPEN Facility 1 SPACE RO SPACE ROAD 1 AD C C C 2 RO C ACTIVE OPEN AD SPACE & PARK EXCLUSIVE 3 50’ CUD ACCESS EASEMENT STEP SYSTEM (APPROX.) 31 US-2 TRAIL St SYSTEM o SEE LANDSCAPE Fa rm BUFFER NOTE cil wa ity te 3 r STEP SYSTEM (APPROX.) SEE LANDSCAPE BUFFER NOTE C Way ley Har Crusade Road Landscape Buffer Note: Preserve existing vegetation in all areas where possible to satisfy the bufferyard requirements specified in Rutherford County Zoning Code. A certified Arborist shall perform a site visit and TYP. CORNER LOT TYPE 1 LOT TYPE 2 LOT SINGLE-FAMILY UNIT verify any potential locations where supplemental vegetation may be necessary. SIDEYARD SETBACK EXHIBIT LOT CONFIGURATION DETAIL LOT CONFIGURATION DETAIL TYPICAL UNIT DETAIL PROPOSED PLANNED UNIT DEVELOPMENT CONCEPT SITE PLAN 10.
PUD Established Development Standards: Current Zoning: RM - (Medium Density Residential) Proposed Zoning: PUD - (Intended for Residential Development) Intended Development Type: Dwelling, Single Family Gross Property Acreage: 57.01 Acres (±2,483,361 SF) Development Standards Type 1 Lot Type 2 Lot • Proposed Lot Totals: 52 Lots 85 Lots • Typ. Unit Footprint: ±1,440 SF (See SFU Detail) ±1,440 SF (See SFU Detail) • Max. Gross Floor Area per Unit: ±2,500 SF ±2,500 SF • Min. Lot Area: 6,270 SF (57’ x 110’) 7,125 SF (57’ x 125’) • Min. Lot Width: 57.0' 57.0' • Max. Lot Coverage: 40% 40% • Min. Front Yard Setback: 35.0’ 35.0’ • Min. Rear Yard Setback: 20.0’ 20.0’ • Min. Side Yard Setback: 15.0' Total (5' Min.) 15.0' Total (5' Min.) 1. Parking for residential units will comply with Rutherford County requirements 2. Each Single Family Dwelling shall contain Three to Four bedrooms 3. Each Single Family Dwelling shall provide parking as follows: (Two Garage Parking Spaces & Four Driveway Parking Spaces - Total of Six) 4. All proposed streets will be designated as public ROW 5. All streets have been designed to comply with Rutherford County Subdivision regulations 6. All mail service shall be provided via CBU (See page 14-15) 7. All on-site utilities shall be installed underground 8. HVAC units shall be located to the rear or sides of each dwelling unit 9. Sanitary Sewer shall be handled via STEP System 10. All home owners will be required to join a Home Owners Association (HOA) 11. All common areas / amenity spaces shall be owned and maintained by HOA 12. The HOA shall be responsible for the continued maintenance of all common open spaces and governing the use of facilities within. Details to be included within a Covenants & Restrictions document to be submitted at a later date. Existing Zoning Comparison: Permitted Lots under (RM) Classification • Min. Lot Area for (RM) district = 15,000 SF • Total Site Area / Min. lot area for RM district = Max. allowable lots if 100% of site is developed • 2,483,361 / 15,000 = 165.55 Permitted Lots • 165.55 Permitted Lots / 57.01 Acres = 2.9 Allowed Gross DU/AC Proposed Lots under (PUD) Classification • Total Proposed Units = 137 Single-Family Dwellings • Total Proposed Units / Total Site Area, in acres • 137 Units / 57.01 Acres = 2.40 Proposed Gross DU/AC Exclusive Residential Net Density Calculation • Total Open Space Required = 6.54 AC • Total Provided STEP Area = 13.39 AC • 57.01 - (13.39 + 6.54) = 37.07 Acres 137 DU / 37.07 = 3.7 DU/AC PROPOSED PLANNED UNIT DEVELOPMENT 11. 9. DEVELOPMENT STANDARDS
N PHASE 1 PHASE 2 PHASE 1 PHASE 2 PROPOSED PLANNED UNIT DEVELOPMENT LOT TYPE / SIDEWALK EXHIBIT 10. 12.
SYMBOL LEGEND Type 1 Lot (52 Total Units) Type 2 Lot (85 Total Units) Provided (5’) Sidewalk (Provided as Shown) As shown in the Lot Type / Sidewalk exhibit, a total of 137 dwelling units have been proposed with- in the subject (PUD). A five (5.0’) sidewalk has been provided as shown across the site to promote walkabillity and alternate forms of access to the amenities areas. TYPICAL STREET SECTION TYPICAL STREET 4' 5' 2' 2' TYPICAL CARTWAY WIDTH: 24' 2' 11' FRONT SETBACK: 35' TYP. RIGHT OF WAY: 50' FRONT SETBACK: 35' TYP. PROPOSED PLANNED UNIT DEVELOPMENT 13. 11. LOT TYPE / SIDEWALK EXHIBIT
N PHASE 1 PHASE 2 PHASE 1 PHASE 2 PROPOSED PLANNED UNIT DEVELOPMENT PHASING EXHIBIT 12. 14.
SYMBOL LEGEND Open Space Total Provided: ±8.45 Acres Usable Open Space Total Provided: ±2.52 Acres S.T.E.P. System Area Total Provided: ±13.39 Acres PHASING SUMMARY PHASE 1 REQUIRED PROVIDED • Est. Date of Construction: (N/A) (Winter / Spring 2022) • Phase Area: (N/A) (±1,255,247 SF) or (28.8 AC) • Proposed Units: (N/A) (61 Total Units) • Lot Density: (N/A) (2.11 Gross DU/AC) Additional provisions included in this phase include: - 1 Stormwater Facility - Active / Passive Open Space - Cluster Mailbox Units (and 3 Provided Parking Spaces) PHASE 2 REQUIRED PROVIDED • Date of Construction: (N/A) (Summer / Fall 2022) • Phase Area: (N/A) (±1,235,934 SF) or (28.3 AC) • Proposed Units: (N/A) (76 Total Units) • Lot Density: (N/A) (2.68 Gross DU/AC) Additional provisions included in this phase include: - 2 Stormwater Facilities - Passive & Active Open Space - Trail System - Cluster Mailbox Units (and 3 Provided Parking Spaces) PROPOSED PLANNED UNIT DEVELOPMENT 13. 15. PHASING EXHIBIT
* LOCATION AND GRADE LIMESTONE WOOD CHIP SURFACE TO LIMESTONE OF WOOD CHIP TRAIL TO BE SELECTED BY OWNER BE FINALIZED IN FIELD BY CONTRACTOR. 5.0' OPEN SPACE EXHIBIT 6" MIN. FILTER CLOTH REQUIRED LIMESTONE TRAIL DETAIL 5 WOOD CHIP TRAIL DETAIL PHASE 2 PHASE 1 NOT TO SCALE 1 5 PROPOSED PLANNED UNIT DEVELOPMENT 4 2 2 1 6 3 3 7 16. 14. 5 5 1 6 PHASE 2 PHASE 1 5 N
OPEN SPACE SYMBOL LEGEND "Any land or area within the boundaries of a development, the preservation of which in its present use would: Conserve & enhance natural or scenic resources; Protect streams or water supply; Open Space Promote the conservation of soils, wetlands or other environmentally sensitive areas; Enhance the value to the public of abutting or neighboring parks, forests, wildlife preserves, nature reservations or sanctuaries; or Enhance recreation opportunities" (§902.k.2.a) "An area or areas within the boundaries of a development that are designed, set aside, Usable Open Space and maintained for either passive or active recreation, and are available for the use of all residents of the development" (§902.k.2.b) OPEN SPACE SUMMARY REQUIRED PROVIDED • Open Space: (190,006 SF) or (4.36 AC) (± 368,182 SF) or (± 8.45 AC) • Usable Open Space: (95,003 SF) or (2.18 AC) (± 109,820 SF) or (± 2.52 AC) Required Open Space Calculation: ([Gross Project Area] - [STEP System Area] x [10%] = Required Open Space) ([2,483,361] - [583,293] = [1,900,068] x [0.10] = [190,006 SF] or [4.36 AC]) Required Usable Open Space Calculation: ([Required Open Space] x [50%] = Required Usable Open Space) ([190,006] x [0.50] = [95,003 SF] or [2.18 AC]) AMENITIES SYMBOL LEGEND 1 Stormwater Facility 2 Cluster Mailbox Unit & Provided Parallel Parking (3 Spaces) 3 Park / Open Lawn 4 Playground (Commercial Grade) 5 Provided Bufferyard (See Page 10 for more information) 6 5' Wide Limestone Trail System 7 50' Wide Exclusive CUD STEP Access Simply Ryan Communities are ideally setup using Cluster Boxes (CBU’s) for mail delivery. Improved street and community appeal Mail Security Required By USPS in many “Urban” designated areas Reduced cost per Home vs Individual Mailboxes Site Plans should incorporate CBU loca- tions and take a planned approach prior to install. Multiple CBU locations will be common and preferred in Simply Ryan communi- ties based on convenience and commu- nity layout. Simply Ryan jobs often do not have the required open space area needed to install multiple units on a cen- Example of Playground tral site. Example of CBU Example of Limestone Trail PROPOSED PLANNED UNIT DEVELOPMENT 15. 17. OPEN SPACE EXHIBIT
*Example of Typical Single-Family Dwelling Floorplan *Provided graphic demonstrates an example of one housing option proposed within this development. Alternative housing options and layouts shall be made available to prospective buyers. Upper Level Main Level PROPOSED PLANNED UNIT DEVELOPMENT ARCHITECTURAL CHARACTERISTICS 16. 18.
Architectural Characteristics • Building Heights shall comply with the requirements set forth for (RM) Zoning of (35’ Max.) • All proposed dwellings shall be maximum of two stories • All proposed dwellings shall contain a minimum of three; and a maximum of four bedrooms • Typical Unit Footprint: (See Page 11) • Maximum Lot Coverage: (See Page 11) • Typical Dwelling Size: (See Page 11) Material Characteristics Proposed Building Materials may differ dependent on the housing option chosen by the prospective tenants. All units shall utilize a mixture of the following materials to create a cohesive neighborhood character: ~ Hardi Siding & Vinyl Accents ~ Stone Water Table *Architectural Renderings Monument Entry Sign PROPOSED PLANNED UNIT DEVELOPMENT 17. 19. ARCHITECTURAL CHARACTERISTICS
NVR - IRWIN PROPERTY PLANNED UNIT DEVELOPMENT - REGULATING PATTERN BOOK - Submission Date: • December 15th, 2020 Revision Date: • January 28th, 2021 • March 25th, 2021 • July 13th, 2021 • August 6th, 2021 © Copyright 2021, PVE Engineering, LLC
You can also read