Comfort takes Contents on new Product Line Up meaning with 4 Inverter Technologies 7 the power of Cleaning-Free Pipe technology Reuse Technology 9 Advanced Technology Our technologically advanced Mr. Slim for High Efficiency 10 Power Inverter systems improve comfort, operate with significantly less noise, Wi-Fi Controller 11 ... and provide increased energy savings. MA Wall Controller 12 Zone Controller 14 System Controls 16 Function List 25 Specifications 27 02 03
Product Line-up 1- & 3-phase 1- & 3-phase 1- & 3-phase 1- & 3-phase See 1-phase 2.5kW 1-phase 3.5kW 1-phase 5.0kW 1-phase 6.0kW 1-phase 7.1kW 3-phase 20.0kW 3-phase 25.0kW Remote Controller 10.0kW 12.5kW 14.0kW 17.0kW Page PLA Series 20 Wide Power optional optional optional 4-Way Cassette PLA-M71EA-A PLA-M100EA-A PLA-M125EA-A PLA-M140EA-A Ceiling Cassette SLZ 18 Series optional optional optional SLZ-KF25VA3 SLZ-KF35VA3 SLZ-KF50VA3 SLZ-KF60VA3 Compact SEZ 19 Bulkhead Series SEZ-KD25VAQ(L) SEZ-KD35VAQ(L) SEZ-KD50VAQ(L) SEZ-KD60VAQ(L) SEZ-KD71VAQ(L)* standard for optional SEZ-VAL PEAD 21 Series PEAD-M71JAAD PEAD-M100JAAD PEAD-M125JAAD PEAD-M140JAAD standard optional optional optional Ceiling- Concealed PEA 22 Series optional optional optional PEA-M100GAA PEA-M125GAA PEA-M140GAA PEA-RP170WJA PEA-RP200WJA PEA-RP250WHA Ceiling- PCA-KA 23 Suspended Series optional optional optional PCA-M50KA PCA-M60KA PCA-M71KA PCA-M100KA PCA-M125KA PCA-M140KA Wall- PKA 24 mounted Series standard optional optional PKA-M71KAL PKA-M100KAL R410A P Series S Series SUZ-KA25VAD2 SUZ-KA35VAD2 SUZ-KA50VAD2 SUZ-KA60VAD2 SUZ-KA71VAD2 PUZ-RP170V(Y)KA PUZ-RP200YKA PUHZ-RP250YKM Outdoor Unit R32 P Series PUZ-ZM71VHA-A PUZ-ZM100V(Y)KA PUZ-ZM125V(Y)KA PUZ-ZM140V(Y)KA *SEZ/SLZ indoor units should be connected to an SUZ outdoor unit. *PKA-M71KAL only available with PUZ-ZM7VHA. 04 05
Limited power Limited energy savings Insufficient power Inverter Technologies Electricity is wasted when needed Mitsubishi Electric inverters ensure a high level of performance, including the optimum control of operation frequency. As a result, optimum power is applied in all heating/cooling ranges, Heat Compressor and maximum comfort is achieved while consuming minimal energy. Fast, comfortable exchanger operation and low running cost - that’s the Mitsubishi Electric promise. Power Heat receiver exchanger How Do Inverters Work? Inverters electronically control theLEV1 LEV2 electrical voltage, current and frequency of electrical devices such as the compressor motor in an air conditioner. They receive information from sensors monitoring operating conditions and adjust the revolution speed of the compressor, which directly regulates air conditioner output. Optimum control of operation frequency results in eliminating the consumption of excessive electricity and providing the most comfortable room environment. Grooved Economic Operation piping Impressively low operating cost is a key advantage of inverter air conditioners. We’ve combined advanced inverter technologies with cutting-edge electronics and mechanical technologies to achieve a synergistic effect that enables improvements in heating/cooling performance efficiency. Better performance and lower energy consumption are the results. True Comfort Below is a simple comparison of air conditioner operation control with and without an inverter. Pipe image Cross-sectional Inverter view Operation Comparison On/Off operation of compressor Optimum control of frequency Non-inverter air conditioner Inverter air conditioner keeps room temperature keeps preset room temperature Change in room temperature Full power Change in room temperature Minimum power temperature consumption temperature Preset Preset ON OFF ON OFF ON getting too hot getting too cool Constant room temperature Compressor operation Time Compressor operation Time The compressors of air conditioners without an inverter start and stop repeatedly to maintain the preset room temperature. This repetitive on/ off operation uses excessive electricity and compromises room comfort. The compressors of air conditioners equipped with an inverter run continuously; the inverter quickly optimises the operating frequency according to changes in room temperature. This ensures energy-efficient operation and a more comfortable room. KEY TECHNOLOGIES Rotary Compressor Scroll Compressor Our rotary compressors use our original “Poki-Poki Motor” Our scroll compressors are equipped with an advanced and “Heat Caulking Fixing Method” to realise downsizing frame compliance mechanism that allows self-adjustment of and higher efficiency, and are designed to match various the position of the orbiting scroll according to pressure load usage scenes in residential to commercial applications. and the accuracy of the fixed scroll position. This minimises Additionally, the development of an innovative production gas leakage in the scroll compression chamber, maintains method known as “Divisible Middle Plate” realises further cooling capacity and reduces power loss. size/weight reductions and increased capacity while also answering energy-efficiency needs. 06 07
MORE ADVANTAGES WITH MITSUBISHI ELECTRIC Joint Lap DC Motor Vector-Wave Eco Inverter Cleaning-Free* Pipe Reuse Technology Mitsubishi Electric has developed a unique This inverter monitors the varying compressor motor frequency motor, called the “Poki-Poki Motor” in Japan, and creates the most efficient waveform for the motor speed. which is manufactured using a joint lapping As a result, operating efficiency in all speed ranges is improved, technique. This innovative motor operates based less power is used, and annual electricity cost is reduced. on a high-density, high-magnetic force, leading to extremely high efficiency and reliability. Smooth wave patternSmooth Wave Pattern Sine-wave drive soft PWM R32 | R410A REFRIGERANT Inverter size has beenInverter size hasusing reduced been reduced insert- using insert moulding, where intothe molding, where the circuit pattern is molded Ability to Use Existing Piping Reduces Pipe Waste and Replacement Time circuit pattern is moulded into Magnetic Flux Vector Sine Wave Drive the synthetic resin. To ensure quiet operation, the synthetic resin. To ensure No need to clean* at the time of system renewal. soft PWM control is quiet This drive device is actually a microprocessor that converts usedoperation, to preventsoft thePWM metallic the compressor motor’s electrical current waveform fromwhine a associated with conventional control is used toinverters. prevent the Chloride residue builds up in existing pipes and becomes a source of trouble. In addition, the iron particles and slime produced as a result conventional waveform to a sine wave (180°conductance) to metallic whine associated with of compressor failure lead to problems. To counter this, various original Mitsubishi Electric technologies have been combined to enable the achieve higher efficiency by raising the motor winding utilisation conventional inverters. introduction of “cleaning-free pipe reuse”. ratio and reducing energy loss. This feature is available in the PUZ-ZM71-200. PAM (Pulse Amplitude Modulation) Reluctance DC Rotary Compressor PAM is a technology that controls the current waveform so that it Powerful neodymium magnets are used in the rotor of the resembles the supply voltage wave, thereby reducing loss and realising more efficient use of electricity. Using PAM control, 98% Why Can’t Existing Piping Be Used? reluctance DC motor. More efficient operation is realised by strong of the input power supply is used effectively. R22 Refrigerant 1 2 R32 | R410A Refrigerant magnetic and reluctance torques produced by the magnets. Without PAM control With PAM control Without PAM Without control PAM control With With PAM PAM control control Problem Problem Result Supply DC compressor Neodymium Supply Supply voltage voltage motor (rotor) magnets voltage At time of renewal Chloride residue Current Time Time High heat generated Accelerated deterioration Current Time Time during operation of refrigerant oil Current Time Increased chloride Time At time of residue PAM adjusts the form of the current wave so that it becomes close to that of the supply compressor failure Refrigerant circuit PAM adjusts voltage wave.the form High of the current harmonics wave soand are reduced that98% it becomes close to is of the electricity that of the supply utilized. Iron particles and slime malfunctions and voltage wave. High harmonics are reduced and 98% of the electricity is utilized. causes failure Magnetic torque PAM adjusts the form of the current wave so that it becomes close to that of the supply + voltage wave. High harmonics are reduced and 98% of the electricity is utilized. Reluctance torque Merits of PAM Control Merits of PAM Control Power increased Power increased Efficient voltage increase Efficientincreased realises voltage increase power Cleaning pipe or replacing with new pipe is required Highly Efficient DC Scroll Compressor Significant energy savings Merits of PAM Control realises increased power PAM Significant Remarkable energy savings reduction in power Power increased Without PAM control PAM With PAM control Higher efficiency has been achieved by adding Remarkable loss reduction in power Supply saves electricity Cleaning pipe or replacing with new pipe is required loss saves electricity Efficient voltage voltageConventional increase a frame compliance mechanism to the DC scroll realises increasedConventional inverter power inverter compressor. The mechanism allows movement Significant energy savings Current Time PAM Remarkable reduction in power Time in the axial direction of the frame supporting the Limited power cradle scroll, thereby greatly reducing leakage loss saves electricity Limited energy savings Limited power Insufficient power Conventional Mitsubishi Electric’s Original Replacement Technologies and friction loss, and ensuring extremely high Limited energy Electricity savings is wasted Insufficient whenPAM adjusts power needed inverter the form of the current wave so that it becomes close to that of the supply Countermeasure for Problem 1 Countermeasure for Problem 2 Electricity is wasted when needed efficiency at all speeds. voltage wave. High harmonics are reduced and 98% of the electricity is utilized. Technology 1: Technology 2: Power Receiver and Twin LEV Control Limited Merits of PAMpower Control Power increased Original High-Quality Filtration Friction Reduction (moving parts in compressor) Limited energy savings Insufficient power Efficient voltage increase Fixed scroll Leakage loss (minimum) Mitsubishi Electric has developed a power receiver and twin realises increased power Our original high-quality filtration device called the “Wide Strainer” Friction inside the compressor is reduced by using an original Electricity is wasted when needed linear expansion valves (LEVs) circuit thatSignificant optimisesenergy savings compressor Remarkable reduction in power PAM is equipped inside the refrigerant inlet and outlet pipe. The “Wide Mitsubishi Electric technology called the “Heat Caulking Frame can move in direction Thrust gas power (minimum) performance. This technology ensures optimumloss saves control electricity in Conventional Strainer” traps iron particles and provides cleaning-free pipe reuse. Fixing Method” or coating the edge of the blade in the scroll of axis response to Heat Compressor operating waveform and outdoor temperature. inverter In addition, improvements to the metal used in the bearings of our compressor, thereby suppressing the increase in temperature Heat exchanger Compressor Thrust friction loss (minimum) Operating efficiency has been enhanced by tailoring the system exchanger Limited power new scroll compressors provide more robust units. that causes refrigerant oil deterioration. to the characteristics of R410A refrigerant. Limited energy savings Insufficient power Power Technology 1 ElectricityHeat is wasted when needed Secondary back-pressure chamber Wide Strainer Substantial reduction in leakage minimises thrust friction loss Power receiver Original Heat exchanger High-quality Filtration “Wide strainer” receiver exchanger and friction loss LEV1 LEV2 Our original high-quality filtration device Primary back-chamber minimises LEV1 LEV2 called the “Wide strainer” is equipped inside leakage loss Heat Compressor the refrigerant inlet and outlet pipe. The Frame Cradle scroll exchanger “Wide strainer” traps iron particles and Existing piping can be used without cleaning* provide Heat cleaning-free Compressor pipe reuse. In exchanger Grooved Powerpiping addition, improvements to the metal used in Heat Grooved piping receiver the bearings of our new scroll compressors exchanger Power Heat Heat Caulking Fixing Method provide more robust units. receiver exchanger To fix internal parts in place, a “Heat Caulking LEV1 LEV2 LEV1 LEV2 Fixing Method” is used, replacing the former arc spot welding method. Distortion of internal Cautions when using existing piping parts is reduced, realising higher efficiency. Pipe image • When removing an old air conditioning unit, please make sure to perform the pump-down process and recover the refrigerant and refrigerant oil. Grooved Piping Cross-sectional view Pipe image Grooved piping • Check to ensure that the piping diameter meets Mitsubishi Electric specifications and piping thickness meets Australian standards. Cross-sectional view High-performance grooved piping Grooved piping • Check to ensure that the flare is compatible with R410A/R32. isNon-inverter used in heat exchangers air conditioner tooperation of compressor On/Off Inverter air conditioner Optimum control of frequency increase the heat exchange keeps area. room temperature keeps preset room temperature On/Off operation of compressor Optimum control of frequency*Cleaning-Free Pipe Reuse Technology specifically applies to piping which is contaminated with chlorine residue, iron particles and slime. Non-inverter air conditioner Inverter air conditioner keeps preset room temperature DC Fan Motor Change in room temperature keeps room temperature Full power Pipe image Change in room These contaminants are typically found in piping in which the previous system utilised R22 refrigerant. Cleaning-Free Pipe Reuse Technology cannot be Change in room Cross-sectional view temperature A highly efficient DC motor drives the fan of the outdoor unit. temperature Full power Change in room Minimum power used to clean pipes which contain foreign matter other than what can be generated from an operating air conditioner. temperature temperature consumption Efficiency is much higher than an equivalent AC motor. temperature Minimum power temperature consumption Preset Optimum control of frequency temperature On/Off operation of compressor 08 Non-inverter air conditioner Inverter air conditioner Preset ON OFF ON OFF ON keeps room temperature keeps preset room temperature 09 Preset Pipe image Preset Change in room ON OFF ON OFF ON temperature Full power Constant room temperature Change in room getting too hot getting too cool Cross-sectional viewgetting too hot temperature Minimum power erature cool getting too Time Constant room temperature consumption rature Compressor operation Compressor operation Time et
Advanced Technology for High Efficiency Econo Cool Energy-Saving Feature Demand Function (Onsite Adjustment) Control Your Comfort “Econo Cool” is an intelligent temperature control feature that adjusts the amount of air directed towards the body based on The demand function can be activated when the unit is equipped with a commercially available timer or an On/Off switch is added to the CNDM Anywhere, Anytime the air-outlet temperature. The setting temperature can be raised connector (option) on the control board of the outdoor unit. Energy by as much as 2°C without any loss in comfort, thereby realising consumption can be reduced up to 100% of the normal consumption a 20% gain in energy efficiency. (Function only available during according to the signal input from outside. manual cooling operation.) [Example: Power Inverter Series] Limit energy consumption by changing the settings of SW7-1, SW2 and Conventional Econo Cool SW3 on the control board of the outdoor unit. The following settings are possible. Ambient Temperature 35°C 35°C Set Temperature 25°C 27°C SW7-1 SW2 SW3 Energy Consumption CONTROL * Perceived Temperature 30°C 29.3°C OFF OFF 100% ON OFF 75% Econo Cool Mode ON Controls A comfortable room environment is maintained even when ON ON 50% setting the temperature 2°C higher than the conventional cooling mode. OFF ON 0% (Stop) *PUZ outdoor only Demand Response Capable Superior Customisation Wi-Fi CONTROL*1 Based on the connection of a demand response enabling device This innovative technology places multiple functions of your (DRED), Demand Response Mode is activated in response to signals Wi-Fi Control unlocks the door to sent from the electric power company at times when it is necessary to air conditioner at your fingertips. smarter heating or cooling, for total Turning the unit On/Off, adjusting reduce peak demand. home comfort wherever you are. set temperature, changing mode, fan speed and airflow direction are all possible. This innovative technology connects AIR QUALITY your Mitsubishi Electric air conditioner Fresh-air Intake Long-life Filter to your smartphone, tablet or online Indoor air quality is enhanced by the direct intake of fresh A special process for the entrapment surface improves the account, giving you the freedom to Develop Operating Rules Tailor your system to always exterior air. filtering effect, making the maintenance cycle longer than that of fully control each unit on-the-go via an units equipped with conventional filters. meet your needs. Unlock internet connection from anywhere the full potential of your air High-efficiency Filter Filter Check Signal in the world. conditioner, program your system This high-performance filter has a much finer mesh compared to to automatically turn On/Off at standard filters and is capable of capturing minute particulates Air conditioner operating time is monitored, and the user is specific times, change settings, floating in the air that were not previously caught. notified when filter maintenance is necessary. and develop temperature rules to *1 Optional upgrade adapter required per unit. ensure superior comfort AIR DISTRIBUTION Requires an Internet connection and the App downloaded from the App Store or GooglePlay Store on your smartphone day after day. or tablet with the latest Operating System available. Auto Fan Speed Mode High Ceiling Mode *2 To use Amazon Alexa to control your air conditioner, you will NEW Wi-Fi Voice Control need an Amazon Echo device. *3 To use Google Assistant to control your air conditioner, you will with Amazon Alexa and The airflow speed mode adjusts the fan speed of the indoor unit In the case of rooms with high ceilings, the outlet-air volume can be need a Google Home smart speaker. Google Assistant automatically according to the present room conditions. increased to ensure that air is circulated all the way to the floor. Mitsubishi Electric air conditioning systems connected with Wi-Fi Horizontal Vane Wi-Fi FEATURES Low Ceiling Mode Control*1 are now also Amazon The air outlet vane swings up and down so that the airflow is Alexa*2 and Google Assistant*3 spread evenly throughout the room. If the room has a low ceiling, the airflow volume can be reduced enabled! This means you can for less draft. »» View & control from anywhere in the world enjoy hands-free control. Vertical Vane »» Enhance energy savings »» Set up 7 day weekly schedule The air outlet fin swings from side to side so that the airflow »» Wireless connection using WPS reaches every part of the room. 10 11
MA Wall Controller Weekly Timer Set up to 8 patterns per day including temperature control Setting Example (Restaurant in summer time) 26 Preparation 1 Busy Off-peak Set to higher temperature PAR-40MAA Weekly schedule timer can save two different settings which hours Set to lower temperature hours can be easily switched according to different seasons. 25 7 8 Closing time Temperature setting (°C) In addition, it offers eight different pattern setting per day. Opening User-friendly remote contoller with excellent operability and visibility. (On, Off and temperature setting). time 24 2 4 6 *Weekly Timer cannot be used when on/off Timer is in use. Lunch time Dinner time 23 3 5 Alternate Background Display Night Setback 8-pattern setting 22 The screen background colour can set to black Keep desired room temperatures automatically to suit the atmosphere of the living environment. This function monitors the room temperature and automatically 0 10 12 14 16 18 20 22 24 (Time) activates the heating mode when the temperature drops below Necessary to change temperature settings for cooling/heating times. *Joint research conducted by Mitsubishi Electric. the preset minimal temperature setting. It has the same function for cooling, automatically activating the cooling mode when the Full Dot Liquid-crystal Display Adopted temperature rises above the preset maximum temperature setting. Rotation, Back-up and 2nd Stage Cut-in Functions* (PAR-40MAA) PUZ-M71–200 Easier to read thanks to the use of a full dot liquid-crystal display with backlight, and easier to use owing to adopting a menu format Temperature Range Restriction (1) Rotation and Back-up Functions Operation Pattern that has reduced the number of operating buttons. Function Outline (Back-up Function Only) Prevents Overcooling/Overheating Error occurs on main unit. Using a temperature that is 1°C lower/higher for cooling/heating • Main and Sub units take turns operating according to a Start operation Main Sub Display Example (Operation Mode) results in a 10% reduction in power consumption.* Temperature rotation interval setting. Main Using aRestriction temperaturelimits that the is 1°C lower/higher for heating/cooling unit Run Abnormal condition Range maximum and minimum temperature • If one unit malfunctions, the other unit automatically begins I/U-1 Full Dot LCD results in a 10% reduction in power consumption.* Temperature operation (Back-up Function). settings, contributing to the prevention of overcooling/overheating. Range Restriction limits the maximum and minimum temperature settings,oncontributing to the prevention of overheating/overcooling. Sub *Based Mitsubishi Electric laboratory tests in controlled conditions System Image unit Stop Run *Based on Mitsubishi Electric laboratory tests in controlled conditions System Image I/U-2 Cooling/Dry (Setting example of minimum temp. in 25˚C) O/U-1 O/U-2 19˚C 30˚C (Rotation Function) & (Back-up Function) Main Sub Possible temperature range setting unit unit Error occurs on main unit. Start operation Main Sub Sub Main Main Sub 25˚C 30˚C I/U-1 I/U-2 Main PAR-40MAA Lower temperature limit unit Run Stop Run Abnormal condition I/U-1 Lower temperatures cannot To prevent excessive cooling be selected Energy Efficiency Schedule Sub O/U : Outdoor Unit unit Stop Run Stop Run Precise control of power consumption Recommended for: I/U : Indoor Unit R/C I/U-2 PUZ-M71-200 Offices and Restaurants R/C : Wired Remote Controller 1–28 days 1–28 days The amount of power consumed in each time period is managed so (When the (When the request request codecode "313", is “313”, each each unit operates unit operates alternatively alternately in daily cycle) in daily cycle.) (2) 2ndFunction Stage Cut-in Function that the demand value is not exceeded. The demand control function Auto-Return (2) 2nd Stage Cut-in Function Outline can be set to start and finish in 5-minute units. Additionally, the level Prevents wasteful operation by automatically returning to the Function Outline Operation Pattern (When Cooling) • Number of units operating is based on room tem- can be adjusted to 0, 50, 60, 70, 80 or 90% of maximum capacity, preset temperature after specified operating time • Number of unitsperature operating andispredetermined based on room temperature settings. 2nd Stage Cut-in Function and up to 4 patterns can be set per day. Air conditioning operation and predetermined After adjusting the temperature for initial cooling on a hot summer • Whensettings. room temperature rises above the desired > Set point is automatically controlled to ensure that electricity in excess of the Room temp. = Room temp. > = Set point –4°C day or heating in winter, it is easy to forget to return the temperature setting, therises • When room temperature standby unitthe above starts (2-unitsetting, desired operation). Start operation Sub unit starts operation Sub unit stops contracted volume is not consumed. • When the(2-unit room temperature setting to its original value. The Auto-Return function automatically the standby unit starts operation). falls 4°C below the pre- Main resets the temperature back to the original setting after a specified determined setting, the standby unit stops (1-unit unit Run Setting pattern example • When the room operation). temperature falls 4°C below the I/U-1 period of time, thereby preventing overcooling/overheating. predetermined setting, the standby unit stops (1-unit Start time Finish time Adjusted capacity level System Constraint The Auto-Return activation time can be set in 10-minute units, operation). Sub 8:15 12:00 80% in a range between 30 and 120 minutes. • This function is only available for rotation operation unit Stop Run Stop and when the back-up function is in cooling mode. I/U-2 *Auto-Return cannot be used when Temperature Range Restrictions is in use. System Constraint 12:00 13:00 50% • This function is only available for rotation operation and 13:00 17:00 90% when the back-up function is in cooling mode. Auto-Off Timer 17:00 21:00 50% Turns cooling/heating off automatically after preset time elapses *Applicable to PKA, PCA, PLA and PEAD indoor units only. When using Auto-Off Timer, even if one forgets to turn off the unit, operation stops automatically after the preset time elapses, thereby Easy Maintenance Function Operation Lock PUZ-ZM71–200 preventing wasteful operation. Auto-Off Timer can be set in 10-minute Fixed temperature setting promotes energy efficiency units, in a range between 30 minutes and 4 hours, eliminating all • Monitor operation data of the indoor and outdoor units via the remote controller. In addition to operation start/stop, the operation mode, temperature anxiety about forgetting to turn off the unit. Remote controller also lets you set the operating frequency, allowing easier inspection. setting and airflow direction can be locked. Unwanted adjustment of Recommended for: temperature settings is prevented, and an appropriate temperature Compressor Outdoor Unit Indoor Unit Meeting Rooms and Changing Rooms is constantly maintained, leading to energy efficiency. This feature is 1. Accumulated operating time (×10hr) 4. Heat exchanger temperature (°C) 7. Intake-air temperature (°C) also useful in preventing erroneous operation or tampering. Recommended for: 2. Number of on/off times (×100 times) 5. Discharge temperature (°C) 8. Heat exchanger temperature (°C) Offices, Schools, Public Halls, Hospitals, Computer Server Facilities 3. Operating current (A) 6. Outdoor-air temperature (°C) 9. Filter operating time* (hr) 12 *The filter operating time is the time elapsed since the filter button was reset. 13
Zone Controller Easy to See and Use • A large, full-dot liquid-crystal screen is incorporated, simplifying touch panel operation. PAC-ZC40/80L-E, PAC-ZC40/80H-E • The backlight makes operation in dark rooms possible. Main Screen Zone Control Screen Operation of up to 8 dampers. Occupancy and brightness sensors provide greater comfort while improving energy-saving performance. Control Operation of up to 8 Dampers By controlling the operation of up to eight dampers, excessive power consumption to condition unoccupied areas and areas where air conditioning is not needed can be prevented. Detailed control makes it possible to set operation to suit the user’s needs. Actual size 120x140x25mm (HxWxD) Oven WIP Kitchen Living Occupancy and Brightness Sensors PEAD/ PEA Veranda Occupancy sensors equipped with the controller can detect when you leave the room. By then automatically switching into energy-saving mode the Zone Controller turns the air conditioner Media off, leading to potential energy savings. Dining Brightness sensors detect when a room changes between light and dark and energy-saving with amode can beandenabled accordingly. Air Air Porch Entry Robe Bed 4 The controller Dayused that are is equipped and time settings combined to determine occupancy if the roomwithisthe brightness brightness occupied. sensors sensors When can is no one Intake Outlet WR Robe in theberoom, used operation to automatically turn the switches air conditioner off to energy-saving when Excellent mode. lights Oven Robe for ensuring that off. are switched the air conditioning gets turned off, and thereby WIP Kitchen Living contributing to further energy savings. Bed 3 When “Zone Control” mode is selected among the energy-saving mode settings PEAD/ Master suite Home theater Bed 2 PEA Veranda shown below. The damper is closed. Media LED Indicator Dining The LED indicator in the lower part of the controller clearly shows The LED indicator in the lower part of the controller clearly shows the operation mode. Easily confirm if the air conditioning is On or Off fromthe operation mode. Easily confirm if the air conditioning is on or off a distance. *Setfrom a distance. Robe Bed 4 to all green *Set to display before shipping. all green display before shipping. Robe Brightness Robe sensor: If room light is on, energy-saving control is deactivated. me theater Bed 2 Occupancy Bed 3 Sensor: Judges whether or not someone is in the room by detecting human motion. If the room is unoccupied, air conditioning is switched to energy-saving mode. Touch panel with backlight: A 4.3-inch touch-panel liquid-crystal screen with a backlight has been incorporated. Occupancy Sensor Temperature sensor: Monitors the temperature near the remote controller. PAR-ZC01M-E Remote Controller Wall 10m LED indicator: Indicates the operation mode or room temperature using colours. PAR-ZC01M-E *Setting is required. Remote Controller 110˚ 10m 10m 11˚ 20˚ 31˚ Wi-Fi Compatibility Schedule Setting Can be operated from tablet, smartphone, etc. • Built-in weekly schedule function can control turning the 110˚ Floor Zone Controller air conditioner on and off, and the opening and closing of each Detection distance, right/left detection angle Up/Down detection angle damper. Up to eight patterns can be set for each week, enabling PAC-ZC 40H-E 240 Volt AC 4 zones (max.) operation suitable for each time zone to be set. Energy Saving Mode PAC-ZC 80H-E 240 Volt AC 8 zones (max.) • Night setback function is incorporated. If the room temperature Energy-Saving Mode settings can be selected (see table below) PAC-ZC 40L-E 24 Volt AC 4 zones (max.) is outside of the temperature range setting, heating or cooling PAC-ZC 80L-E 24 Volt AC 8 zones (max.) operation starts automatically. This can prevent condensation or Deactivate Even if no one is detected, Energy Saving Mode is not set excessive temperature rise in the room. Temperature The slide to set desired temperature from presently setting slide set temperature Optional Parts Reduce Airflow Set airflow to "Low" Wi-Fi Control Interface MAC-568IF-E Operation/Stop Stop operation Remote Sensor PAC-SE4ITS-E Zone control Turn off target zone settings Zone Remote Controller PAR-ZC01M-E 14 15
SYSTEM CONTROLS (SUZ and Mr. Slim Power Inverter only) SYSTEM CONTROLS (SUZ and Mr. Slim Power Inverter only) Versatile system controls can be realised by using optional parts, relay circuits, control panels, etc. Versatile system controls can be realised by using optional parts, relay circuits, control panels, etc. MAJOR SYSTEM CONTROL FOR P SERIES AND S SERIES INDOOR UNITS System Examples System Examples Major Optional Indoor Unit S Series & P Series Major Optional Wired Wireless Details Indoor Unit P Series Indoor Unit Details Parts Required Parts Required Remote Controller Remote Controller Outdoor Unit Controller S Series & MXZ Series Outdoor P Series Outdoor A A • Wired Remote Controller 2 Remote PAR-40MAA, PAC-YT52CRA • Up to two remote controllers can be (for PKA, PAC-SH29TC-E is required) PAR-40MAA Controller Control connected to one group. • PAR-40MAA-J PAR-SL97A-E Control Standard equipment With two remote (Wired remote controller) • Wireless Remote Controller (for indoor units compatible controllers, control PAC-YT52CRA • PAC-YT52CRA PAR-40MAA-J PAR-40MAA-J • Both wired and wireless remote PAR-SL97A-E (for SEZ and PLA-RP) with wired remote controllers) can be performed PAC-YT52CRA (Wired remote controller) PAC-YT52CRA controllers can be used in Control PAR-40MAA-J locally and remotely combination. PAC-YT52CRA * When using wired and wireless from two locations. * Set "Main" and "Sub" remote controllers • Wireless Remote Controller Kit for remote controllers. PCA PAR-SL948-E (Example of Simultaneous Twin) B (Example of 1 : 1 system) • One remote controller can control plural air conditioners S Series Outdoor Unit B • MAC-334IF-E/MAC-397IF-E with the same settings (Interface) Relay box (to be purchased locally) Relay box (to be purchased locally) Operation Control • Operation other than On/Off • Adapter for remote On/Off simultaneously. PAC-SE55RA-E by Level Signal Adapter for Adapter for remote e.g. adjustment of temperature, remote fan speed, and airflow) can be • PAR-40MAA On/Off On/Off • One remote controller can Air conditioner can be performed even when remote (Wired remote controller) • Relay box MAC-397IF-E control up to 16 refrigerant started/stopped remotely. controller operation is prohibited. MAC-333IF-E (to be purchased locally) systems (when connected to an In addition, On/Off System Remote Remote MXZ unit, MAC-397IF-E is counted operation by the local control control Group as one system). • PAC-YT52CRA remote controller can be panel Wired remote panel PAR-SL97A-E • Timer control is possible with an • Remote control panel PAR-40MAA-J PAR-40MAA-J (Wired remote controller) controller external timer. Control prohibited/permitted. (to be purchased locally) PAC-YT52CRA PAC-YT52CRA (Example of 1 : 1 system x 2) (Example of 1 : 1 system x 2) • Up to two remote controllers can be connected. P Series Outdoor Unit • PAR-40MAA-J (Wired remote controller) C • PAR-SL100A cannot be used Relay box (to be purchased locally) Relay box (to be purchased locally) • Connector cable for remote display when connected through the PAC-SA88HA-E/PAC-725AD C MAC-397IF-E, or when group Connector cable for Connector cable for • The pulse signal can be turned (10 pcs. x PAC-SA88HA-E) control is used. remote remote On/Off. Operation Control display display • Relay box by Pulse Signal (to be purchased locally) Remote Remote • Operation/emergency signal can be control control received at a remote location. panel Wired remote panel PAR-SL97A-E controller • Remote control panel Outdoor Outdoor (Example of 1 : 1 system x 2) (Example of 1 : 1 system x 2) (to be purchased locally) unit unit S Series Outdoor Unit Indoor Indoor • MAC-334IF-E unit unit • MELANS System controller Indoor unit Indoor unit • PAC-SC51KUA D Remote operation adapter/ Remote operation adapter/ • Remote display panel City Multi PAR-40MAA-J PAR-40MAA-J Connector cable for remote display + indoor unit (power supply unit) Connector cable for remote display + (to be purchased locally) PAC-YT52CRA PAC-YT52CRA Relay box Relay box • Operation/emergency signal can be Group of air conditioners can be PAR-40MAA-J PAR-40MAA-J PAR-40MAA-J PAR-40MAA-J received at a remote location (when M-NET Connections PAC-YT52CRA PAC-YT52CRA PAC-YT52CRA PAC-YT52CRA controlled by MELANS system P Series Outdoor Unit Remote Display of • Connector cable for remote display controller (M-NET). •P AC-SJ95MA-E (M-NET channeled through the Operating Status PAC-SA88HA-E/ PAC-725AD MAC-333IF-E converter) (10 pcs. x PAC-SA88HA-E) MELANS Operating status can PAC-SF40RM No-voltage signal, system controller MELANS M-NET adapter • MELANS System controller AE-200E system controller PAC-SF81MA-E be displayed at when channeled through the •P AC-SC51KUA (power supply • Relay box (to be purchased locally) AE-200E a remote location. unit) Remote Remote • Remote operation adapter display display panel panel PAC-SA88HA-E 12V DC signal). PAC-SF40RM PAC- PAR-40MAA-J PAR-SL97A-E YT52CRA *Unable to use with wireless remote controller. (Example of 1 : 1 system) (Example of Simultaneous Twin) E • Weekly Timer: On/Off and up to 8 pattern temperatures can be set for each calendar day. (Initial setting) Timer Operation: • On/Off Timer: On/Off can be set once each within 72hr. in intervals Allows On/Off of 5-minute units. operation with timer - Standard functions of PAR-40MAA *For control by an external PAR-40MAA-J • Auto-Off Timer: Operation will be timer, refer to B: Operation Control by Level Signal. switched off after a certain time elapse. Set time can be changed (Example of 1 : 1 system) from 30 min. to 4 hr. at 10 min. intervals. *Simple Timer and Auto-off Timer cannot be used at the same time. 16 17
SLZ Series SEZ Series 4-WAY CEILING CASSETTE COMPACT BULKHEAD SLZ-KF25/35/50/60VA3 SEZ-KD25/35/50/60/71VAQ(L) Provides a smart solution to comfort and efficient air conditioning. Our ultra-compact design saves installation space and provides a flexible solution. New Design Compact Ceiling-concealed Units Impressively Quiet The straight-line form introduced has resulted in a beautiful Detects occupants Only the intake-air grille and outlet vents are visible when S Series units offer quiet operation at a hushed noise level square design. Its high affinity ensures the ability to blend in 3D i-see Sensor detects the occupancy of people in the room using this ceiling-concealed indoor unit. The rest of the unit is of 23dB (SEZ-KD25/35), ensuring a calm and comfortable seamlessly with any interior. The indoor unit is an ideal match for and sets the air conditioning settings accordingly. This makes conveniently hidden in the ceiling cavity, essentially leaving the environment. office or store use. Of course, design matched 2x2 (600mm x automatic power-saving operation possible in places where the ceiling and walls free of bulky looking devices and maintaining They’re so quiet that you may find yourself checking to see if 600mm)600 mm ceiling 600 mm construction specifications. number of people entering and exiting is large. Additionally, a high-class interior décor. The compact units require minimal they’re on. when the area is continuously unoccupied, the system switches space and can be installed in buildings with lowered ceilings, where exposed units were the rule in the past. Noise Level to a more enhanced power-saving mode. Depending on the 600 mm 600 mm setting, it will save additional capacity or stop operation together. A Air inlet Quiet Sound Human Train Passenger Library B Air outlet of Rustling Hearing Limits Interior Car Interior Interior Detects people's position Leaves (Extremely Quiet) C Access door (40km/h) Once the position of a person is detected, the duct angle of D Ceiling surface E Canvas duct the vane is automatically adjusted in that direction. Each vane F Air filter can be independently set to "Indirect Airflow" or "Direct Airflow" G Inlet grille 80dB 60dB 40dB 23dB 20dB 10dB according to taste. 245 mm Horizontal Airflow Detects number Drain Pump (Optional) of people The new airflow control completely eliminates that uncomfortable * As of Aug 2015. Among compact 4-way cassettes The PAC-KE07DM-E drain pump is now available as an option. drafty-feeling with for system ceiling. (Anthe introduction incompany of a horizontal airflow that spreads investigation.) 245 mm With the pump, a drain hose length of up to 550mm can be used, across the ceiling - the ideal airflow for offices and restaurants. Detects people’s adding to increased installation possibilities. Airflow distribution* position SLZ-KF60VA * As of Aug 2015. |Among Flowcompact angle,4-way cooling at 20°C cassettes (ceiling height 2.7m) Horizontal for system ceiling. (An incompany investigation.) Ceiling height : 2.7 m (m/s) Detects position 2.7 2.0 (m/s) 2.0 and number of people 360° 1.0 1.0 Cold wind Detection 0.5 0.5 does not Detects floor 2 temperature bother. 2.7m Height (m) Horizontal 7.2m Ceiling height : 2.7 m 8 sensors 2.71 Horizontal Horizontal (m/s) 1.1m 2.0 2.0 0.5 1.0 airflow airflow 1.0 0.5 Cold wind 12m 8 7 6 4 53 2 1 1 2 3 4 5 6 7 8 does not 2 bother. Height (m) 0 Floor surface *In case of a 2.7m ceiling 4 3 2 1 0 1 2 3 4 Horizontal(m) Floor distribution Floor distance Horizontal (m) *Vane angle: Horizontal 1 18 airflow airflow 19 0 4 3 2 1 0 1 2 3 4 Floor distance (m)
PLA Series PEAD Series 4-WAY CEILING CASSETTE CEILING-CONCEALED PLA-M71/100/125/140EA PEAD-M71/100/125/140JAAD The thin, ceiling-concealed indoor units of the PEAD series is the Advancements in PLA Series improve style and performance for indoor comfort. answer for the air conditioning requirements of buildings with minimum ceiling installation space and wide-ranging external static pressure. Automatic Grille Lowering Function (Optional) Energy-saving efficiency has been improved, thereby reducing Detects occupants An automatic grille lowering function is electricity consumption and contributing to a further reduction in available for easy filter maintenance. 3D i-see Sensor detects the occupancy of people in the room Special wired and wireless remote Detects number operating cost. and sets the air conditioning settings accordingly. This makes of people controllers can be used to lower the intake 1.2m automatic power-saving operation possible in places where the grille for maintenance. 1.6m number of people entering and exiting is large. Additionally, Lighter Weight Wide Selection of Fan Speeds and External when the area is continuously unoccupied, the system switches Grille Elevation Remote Controller (comes with the 2.0m Compared to the previous PEA-RP·EAQ (7.1kW-14.0kW) Static Pressure to a more enhanced power-saving mode. Depending on the automatic elevation panel) Detects people’s models, the unit weight has been reduced by an average of Five-stage external static pressure conversions and three fan speed setting, it will save additional capacity or stop operation together. position 2.4m 27kg. This significant weight reduction allows for increased selections are available. Capable of being set to a maximum of ease of installation. 125Pa, units are applicable to a wide range of building types. Detects people's position 2.8m Once the position of a person is detected, the duct angle of 3.2m the vane is automatically adjusted in that direction. Each vane Drainage Pump Installed as Standard High Energy-Saving Efficiency can be independently set to "Indirect Airflow" or "Direct Airflow" Detects position 3.6m 360° The drainage pump can lift water up to 700mm from the Compared to the previous PEA-RP·EAQ (7.1kW-14.0kW) models, according to taste. and number of people 4.0m Detection lower surface of the indoor unit's main body. PEAD-RP models achieve enhanced energy efficiency through Detects floor adopting a highly efficient DC fan motor. This contributes to a Wired remote controller Wireless remote controller temperature 2.7m (PAR-40MAA) (PAR-SL100A-E) reduction in electricity consumption. Detects number 7.2m of people 8 sensors Automatic elevation to four meters 1.1m Horizontal Airflow 491mm Capacity Rated Previous PEA-RP PEAD-M EER/COP 12m Max. Detects people’s The new airflow control removes that uncomfortable drafty 700mm Rated EER 2.86 3.50 22% UP 8 position 8 7 6 4 53 2 1 1 2 3 4 5 6 7 feeling with the introduction of a horizontal airflow that spreads 7.1 kW across the ceiling - the ideal airflow for offices and restaurants. 209mm Rated COP 3.35 4.00 19% UP Floor surface *In case of a 2.7m ceiling Airflow distribution* Rated EER 3.28 3.61 10% UP Detects position 10.0 kW 360° Rated COP 3.54 4.12 16% UP and number of people Detection PLA-M140EA | Cooling at ceiling height of 3.2m Detects floor temperature 2.7m Indoor Unit Rated EER 2.95 3.33 13% UP (m/s) 7.2m 3.2 3.0 12.5 kW 2.0 8 sensors 3 1.0 Rated COP 3.64 4.00 10% UP 1.1m 0.5 Rated EER 2.90 3.32 14% UP 12m 14.0kW 8 7 6 4 53 2 1 1 2 3 4 5 6 7 8 2 Height (m) Rated COP 3.74 3.96 6% UP Floor surface *In case of a 2.7m ceiling 1 0 1 2 3 4 5 20 Floor distance (m) 21
PEA Series PCA Series CEILING-CONCEALED CEILING-SUSPENDED PEA-M100/125/140GAA, PEA-RP170/200WJA/250WHA PCA-M50/60/71/100/125/140KA In addition to the conventional 4-speed setting, units are now A stylish indoor unit design and airflow settings for both high For elegance and style, the PEA Series compliments the room with aesthetically equipped with an automatic air-speed adjustment mode. This set- and low ceiling interiors expand installation possibilities. ting automatically adjusts the air-speed to conditions that match pleasing ceiling installation and a vast line-up of performance functions. t h e Stylish Indoor Unit Design room environment. At the start of heating/cooling Drain Pump operation, Installation the Possible Freedom in Installation Flexible Duct Design Enables Use of High-pressure Versatile and easy installation is possible; for example, it is possi- A stylish square-like design is adopted for the indoor units of all airflow is set to high-speed to quickly heat/coolDrainage the room. When Static Fan Optional Drain Pump for outlet bleVersatile andthe to adjust easy installation distance is possible; between for example, the air-intake it isair-outlet and possible models. As a result, the units blend in better with the ceiling. Thethe room height pumping tempera-of the optional drain can be 600mm to adjust the distance between the air-intake vents to create the optimal airflow configuration. and air-outlet vents to A flexible duct design and 150Pa external static high-pressure are Full-Capacity ture reaches the de- Models above ceiling create the optimal airflow configuration. A flexible duct design and 150Pa external incorporated. static The increased high-pressure variation are in airflow options ensures pump has The been pumping increased height of from the 400mm optional surface sired setting, the incorporated. The increased variation operation in airflow that best matches virtually options ensures all room layouts. to 600mm, expanding drain pump has been airflow speed is de- flexibility in choos- increased from Ceiling surface operation that best ing unit location 400mm toduring 600mm,installation work. expanding flexibility creased automatical- in choosing unit location during matches virtually all PCA-GA PCA-KA ly for installation stable comfort- work. Outside Air-Intake Characteristics room layouts. 50 Static pressure (Pa) L-shaped room Long Long � rectangular rectangular room room Room � Room with fixed with fixed ceiling � L-shaped room Equipped with Automatic Air-Speed Adjustment Fresh Outside-Air Intake 0 –50 ceiling fixtures fixtures –100 In addition to the conventional 4-speed setting, units are now Units Units are equipped withwith are equipped a knock- a –150 PCA-RP100–140KA –200 PCA-RP60/71KA equipped with an automatic air-speed adjustment mode. out hole that enables the knock-out hole that enablesinduc- –250 PCA-RP50KA Easier Handling This setting automatically adjusts the air-speed to conditions tion ofthe fresh outside-air. induction of fresh outside-air. –300 0 1 2 3 4 Airflow volume (m 3/min) The new ducted fan coil unit (PEA-RP170/200/250) now has a that match the room environment. At the start of the cooling/ two-piece construction. This allows separation of the indoor unit heating operation, the airflow is set to high-speed to quickly heat exchanger and the fan deck assembly for easier handling in cool/heat the room. Equipped with High/Low Ceiling Modes the roof space. Units are equipped with high and low ceiling operation modes that When the room temperature reaches the desired setting, the make it possible to switch the airflow volume to match room height. unit airflow speed is decreased automatically for stable comfortable The ability to choose the optimum airflow volume makes it possible has cooling/heating operation. Computerised Dehumidification to optimise the breezy sensation felt throughout the room. his Must be reassembled and installed prior to using the system. The fan speed is controlled electronically in dry mode, increasing oor the range and efficiency of dehumidification. Capacity High Ceiling Standard Ceiling Low Ceiling the Strong Gentle 50 3.5m 2.7m 2.5m sier 60 3.5m 2.7m 2.5m . 71 3.5m 2.7m 2.5m 100 4.2m 3.0m 2.6m Start of cooling/heating… After room temperature is stabilized… 125 4.2m 3.0m 2.6m 140 4.2m 3.0m 2.6m 22 23
PKA Series Function List WALL-MOUNTED Standard Optional - Not Available Combination P Series PEA-M100/ PEA- PLA- PEAD- PEA- PKA-M71/ PCA-M50/60/ Indoor Unit 125/140 RP170/ M71/100/125/140EA M71/100/125/140JAAD RP250WHA 100KAL 71/125/140KA GAA 200WJA Category SUZ- Outdoor Unit SUZ-KA PUZ-ZM SUZ-KA PUZ-ZM PUZ-ZM PUZ-RP PUHZ-RP PUZ-ZM PUZ-ZM KA DC Inverter Joint Lap DC Motor 71 71 71 - - 71 71 Magnetic Flux Vector Sine Wave Drive - - - - Reluctance DC Rotary Compressor 71 71 71 - - 71 71 Highly Efficient DC Scroll Compressor - 100-140 - 100-140 100-140 100 - 100-140 Technology Heating Caulking (Compressor) 71 71 - - - 71 71 DC Fan Motor Vector-Wave Eco Inverter - - - PAM (Pulse Amplitude Modulation) - - Power Receiver and Twin LEV Control - - - - - Grooved Piping Felt Temperature Control (3D i-see Sensor) - - - - - - - - i-See Sensor AREA Temperature Monitor - - - - - - - - PKA-M71/100KAL Energy Demand Function - - - Saving Demand Response Capable Elegant design and compact dimensions are ideal for Fresh-Air Intake - - - - - - Air High-Efficiency Filter - - - - - - offices and stores. Quality Long-Life Filter - - - - Filter Check Signal - - - Horizontal Vane (Auto Swing) - - - - - Flat Panel & Pure White Finish Wired Remote Controller Available (Optional) Auto Vane - - - - - A flat panel layout has been adopted for all models. Pursuing a A optional wired remote controller and a terminal block are available Air High Ceiling Mode - - - - - - Distribution design that harmonizes with virtually any interior, the unit colour has to suit various installation sites. Low Ceiling Mode - - - - - - been changed from white to pure white. Auto Fan Speed Mode - - - Installation Drainof Pump the drainOption pump enables Available with a All drain outlet as high as Models On/Off Operation Timer Auto Change Over Quick Clean Grille 800mm Installation above the of thebase of the drain pump indoor enables unit. a drain Drain outlet as highwater as can be Auto Restart The intake grille filter can easily slide out completely. This allows easy discharged800mm easily above even the baseifofthe surface the indoor where unit. Drain waterthe can wall-mounted be The intake grille filter can easily slide out completely, allowing easy Convenience Low-Temperature Cooling cleaning without any special tools (can be washed in water). discharged easily even if the surface where the wall-mounted unit unit does not have direct access outside, increasing the degree cleaning without any special tools making it easy to clean in minutes, washing Low-Noise Operation (Outdoor Unit) - - - in water. does not have direct access outside, increasing the degree of Ampere Limit Adjustment - - - - - - - - - - of freedom for for freedom installation. installation. Operation Lock - - - - - - - - - - PAR-40MAA-J Control *1 PAC-YT52CRA Control *1 Drain Pump System Centraliesd On/Off Control *1 Indoor Unit Control System Group Control *1 800mm Front Grille M-NET Connection *1 Cleaning-free Pipe Reuse Filter Reuse of Existing Wiring - - - Wiring/Piping Correction Function - - - - - - - - - - Installation Drain Pump - - - Pump Down Switch - - - Flare Connection Self-Diagnosis Function (Check Code Display) Maintenance Failure Recall Function *1 Please refer to "System .Control" on pages 16 and 17 for details. * If a numerical figure is listed, the feature is only available with the outdoor unit of that capacity. 24 25
SPECIFICATIONS SPECIFICATIONS 4-way Ceiling Cassette (PLA Series) Ceiling-Concealed (PEAD Series) Indoor Unit PLA-M71EA-A PLA-M100EA-A PLA-M125EA-A PLA-M140EA-A Indoor Unit PEAD-M71JAAD PEAD-M100JAAD PEAD-M125JAAD PEAD-M140JAAD Outdoor Unit SUZ-KA71VAD2 PUZ-ZM71VHA-A PUZ-ZM100VKA-A PUZ-ZM100YKA-A PUZ-ZM125VKA-A PUZ-ZM125YKA-A PUZ-ZM140VKA-A PUZ-ZM140YKA-A Outdoor Unit SUZ-KA71VAD2 PUZ-ZM71VHA-A PUZ-ZM100VKA PUZ-ZM100YKA PUZ-ZM125VKA PUZ-ZM125YKA PUZ-ZM140VKA PUZ-ZM140YKA Refrigerant R410A R32 Refrigerant R410A R32 Power Supply V: 230V, Single-phase, 50Hz Y: 400V, Three-phase, 50Hz Power Supply V: 230V, Single-phase, 50Hz Y: 400V, Three-phase, 50Hz Capacity [Min-Rated-Max] (kW) 2.8 - 7.1 - 8.1 3.3 - 7.1 - 8.1 4.9 - 10.0 - 11.4 4.9 - 10.0 - 11.4 5.5 - 12.5 - 14.0 5.5 - 12.5 - 14.0 6.2 - 13.5 - 15.3 6.2 - 13.5 - 15.3 Capacity [Min-Rated-Max] (kW) 2.8 - 7.1 - 8.1 3.3 - 7.1 - 8.1 4.9 - 10.0 - 11.4 4.9 - 10.0 - 11.4 5.5 - 12.5 - 14.0 5.5 - 12.5 - 14.0 6.2 - 14.0 - 15.3 6.2 - 14.0 - 15.3 Total Input [Rated] (kW) 2.07 1.78 2.43 3.06 3.55 3.55 3.93 3.93 Total Input [Rated] (kW) 2.10 1.85 2.67 3.13 3.66 3.66 4.37 4.37 AEER/EER 3.39 / 3.43 3.77 / 3.98 3.95 / 4.11 3.11 / 3.26 3.42 / 3.52 3.37 / 3.52 3.34 / 3.43 3.30 / 3.43 AEER/EER 3.34 / 3.38 3.63 / 3.83 3.60 / 3.74 3.04 / 3.19 3.32 / 3.41 3.28 / 3.41 3.13 / 3.20 3.09 / 3.20 AEER [Part-load %] *1 - - - 4.40 - - - - AEER [Part-load %] *1 - - - 4.23 - - 4.20 4.09 Cooling Cooling Running Current [Rated] A 9.28 8.10 11.10 5.10 16.60 5.50 18.07 6.40 Running Current [Rated] A 10.49 10.33 12.20 5.20 16.70 6.40 19.77 7.40 Sound In (Lo-Mid-Hi) 28 - 30 - 32 - 34 28 - 30 - 32 - 34 31 - 34 - 37 - 40 31 - 34 - 37 - 40 33 - 37 - 41 - 44 33 - 37 - 41 - 44 36 - 39 - 42 - 44 36 - 39 - 42 - 44 Sound In (Lo-Mid-Hi) 30 - 34 - 39 33 - 38 - 42 36 - 40 - 44 40 - 44 - 49 Pressure dB(A) Pressure dB(A) Level *3 Out (PWL) 55 (69) 47 (67) 49 (69) 50 (70) 50 (70) 50 (70) 50 (70) 50 (70) Level *3 Out (PWL) 55 (69) 47 (67) 49 (69) 50 (70) 50 (70) 50 (70) 50 (70) 50 (70) Air Volume (In) Lo-Mid-Hi L/S 267-283-317-350 267-283-317-350 317-383-433-483 317-383-433-483 350-417-467-517 350-417-467-517 400-433-483-533 400-433-483-533 Air Volume (In) Lo-Mid-Hi L/S 292 - 350 - 417 400 - 483 - 567 492 - 592 - 700 533 - 650 - 767 Capacity [Min-Rated-Max] (kW) 2.6 - 8.0 - 10.2 3.5 - 8.0 - 10.2 4.5 - 11.2 - 14.0 4.5 - 11.2 - 14.0 5.0 - 14.0 - 16.0 5.0 - 14.0 - 16.0 5.7 - 16.0 - 18.0 5.7 - 16.0 - 18.0 Capacity [Min-Rated-Max] (kW) 2.6 - 8.0 - 10.2 3.5 - 8.0 - 10.2 4.5 - 11.2 - 14.0 4.5 - 11.2 - 14.0 5.10 - 14.0 -16.0 5.10 - 14.0 - 16.0 5.7 - 16.0 - 18.0 5.7 - 16.0 - 18.0 Total Input [Rated] (kW) 2.19 2.03 2.94 3.05 3.58 3.58 4.48 4.48 Total Input [Rated] (kW) 2.04 1.93 2.80 3.06 3.52 3.52 4.18 4.18 ACOP/COP 3.61 / 3.65 3.75 / 3.94 3.68 / 3.80 3.50 / 3.67 3.80 / 3.91 3.75 / 3.91 3.49 / 3.57 3.45 / 3.57 ACOP/COP 3.87 / 3.92 3.93 / 4.14 3.86 / 4.00 3.49 / 3.66 3.86 / 3.97 3.81 / 3.97 3.73 / 3.82 3.69 / 3.82 ACOP [Part-load %] *1 - - - - - - - - ACOP [Part-load %] *1 - - - - - - - - Heating Heating Running Current [Rated] (mm) 9.82 9.89 14.02 5.10 16.30 5.90 21.14 7.20 Running Current [Rated] (mm) 10.08 8.80 12.70 5.10 16.00 6.20 18.80 7.10 Sound In (Lo-Mid-Hi) dB(A) 28 - 30 - 32 - 34 28 - 30 - 32 - 34 31 - 34 - 37 - 40 31 - 34 - 37 - 40 33 - 37 - 41 - 44 33 - 37 - 41 - 44 36 - 39 - 42 - 44 36 - 39 - 42 - 44 Sound In (Lo-Mid-Hi) dB(A) 30 - 34 - 39 33 - 38 - 42 36 - 40 - 44 40 - 44 - 49 Pressure Pressure Level *3 Out (PWL) dB(A) 55 (68) 51 (70) 51 (69) 52 (70) 52 (70) 52 (70) 52 (71) 52 (71) Level *3 Out (PWL) dB(A) 55 (68) 51 (70) 51 (69) 52 (70) 52 (70) 52 (70) 52 (71) 52 (71) Air Volume (In) Lo-Mid-Hi 267-283-317-350 267-283-317-350 317-838-433-483 317-383-433-483 350-417-467-517 350-417-467-517 400-433-483-533 400-433-483-533 Air Volume (In) Lo-Mid-Hi 292 - 350 - 417 400 - 483 - 567 492 - 592 - 700 533 - 650 - 767 Max. Running Current A 16.00 19.27 27.96 11.96 28.16 12.16 29.16 12.16 Max. Running Current A 16.00 20.28 29.18 13.18 29.90 13.90 31.10 14.10 Input [Rated] kW 0.04 0.04 0.07 0.07 0.10 0.10 0.10 0.10 Input [Rated] kW 0.17 / 0.15 0.25 / 0.23 0.36 / 0.34 0.39 / 0.37 Dimensions [HxWxD] mm 258 x 840 x 840 298 x 840 x 840 Dimensions [HxWxD] mm 250 X 1100 X 732 250 X 1400 X 732 250 X 1400 X 732 250 X 1600 X 732 Indoor Indoor Unit Unit Panel [HxWxD] mm 40 x 950 x 950 Weight kg 30 29 40 44 Weight [Panel] kg 21 (5) 24 (5) 27 (5) Static Pressure Pa 35 / 50 / 70 / 100 / 125 Dimensions [HxWxD] mm 880 x 840 x 330 943x950x300(+25) 1338 x 1050 x 330 (+40) 943 x 950 x 300 Dimensions [HxWxD] mm 880 x 840 x 330 1338 x 1050 x 330 (+40) (+25) Outdoor Weight kg 54 70 113 114 113 114 113 114 Outdoor Unit Weight kg 54 70 111 112 111 112 111 112 Unit Breaker Size A 20 25 32 16 32 16 40 16 Breaker Size A 20 25 32 16 32 16 40 16 Diameter [Gas/Liquid] mm 15.88 / 9.52 Ext. Diameter [Gas/Liquid] mm 15.88 / 9.52 Piping Ext. Max. Length/Height m 30 / 30 50 / 30 75 / 30 Piping Max. Length/Height m 30 / 30 50 / 30 75 / 30 Cooling *2 °C -15 ~ 52 -5 (-15) ~ 52 Guaranteed Operating Cooling *2 °C -15 ~ 52 -5 (-15) ~ 52 Range [Outdoor] Guaranteed Operating Heating °C -15 ~ 24 -20 ~ 21 Range [Outdoor] Heating °C -15 ~ 24 -20 ~ 21 *1 M EPS compliant at part load. (Rating Conditons) *2 With the optional air protection guide, the operation at -15°C outdoor temperature is possible. Cooling: Indoor 27°C, D.B./19°C, W.B. *3 Sound pressure level measured in anechoic room at 1m. Outdoor 35°C, D.B./24°C, W.B. *1 MEPS compliant at part load. (Rating Conditons) Heating: Indoor 20°C, D.B./15°C, W.B. *2 With the optional air protection guide, the operation at -15°C outdoor temperature is possible. Cooling: Indoor 27°C, D.B./19°C, W.B. Outdoor 7°C, D.B./6°C, W.B. *3 Sound pressure level measured in anechoic room at 1m. Outdoor 35°C, D.B./24°C, W.B. Heating: Indoor 20°C, D.B./15°C, W.B. Outdoor 7°C, D.B./6°C, W.B. 26 27