Modular Metering, Single, and Horizontal Metering - ELECTRIFICATION - SMART BUILDINGS | 1TQC134200E0001 PPT REV.A December 21, 2021 All rights ...
←
→
Page content transcription
If your browser does not render page correctly, please read the page content below
— EXTERNAL —ELECTRIFICATION – SMART BUILDINGS | 1TQC134200E0001 PPT REV.A Modular Metering, Single, and Horizontal Metering December 21, 2021 Slide 1 All rights reserved
— — Proprietary Statement This presentation and any of its contents, including but not limited to images, information, communications, know-how, etc., is the sole property of ABB and/or its Affiliates ("ABB") and are not to be used by you other than to evaluate ABB's products/services. This presentation and any of its contents are not to be disseminated, distributed or otherwise conveyed throughout your organization to employees without the need for this information or to any third parties without the express written permission of ABB. November Slide 2 10, 2021 All rights reserved
— Modular Metering Modular metering product overview This presentation contains confidential and proprietary information intended for sole use by ABB or its representatives. ABB reserves all rights in this January 4, 2022 Slide 3 document and in the subject matter and the illustrations contained therein. Any reproduction, disclosure to a third party, or utilization of its contents—in whole or in part—is forbidden without prior written consent from ABB.
— Modular Metering Mini Mod metering – Maximum of 6 meter sockets. – No upstream main disconnect. – Usage is based on the Six Handle Rule which states that you must be able to throw no more than six handles into the off position to disconnect electrical service. – Up to 600A incoming and 240V. – Sockets 125A and 200A. – Single Phase. – Applications include condo’s, apartment buildings. – Non-expandable. This presentation contains confidential and proprietary information intended for sole use by ABB or its representatives. ABB reserves all rights in this January 4, 2022 Slide 4 document and in the subject matter and the illustrations contained therein. Any reproduction, disclosure to a third party, or utilization of its contents—in whole or in part—is forbidden without prior written consent from ABB.
— Modular Metering Mini Mod III – Layout No male or female end for expansion This presentation contains confidential and proprietary information intended for sole use by ABB or its representatives. ABB reserves all rights in this January 4, 2022 Slide 5 document and in the subject matter and the illustrations contained therein. Any reproduction, disclosure to a third party, or utilization of its contents—in whole or in part—is forbidden without prior written consent from ABB.
— Modular Metering Mini Mod III – Nomenclature Product number guide for Mini Mod III – Product number for illustrative purposes only T MM 6 6 20 R F GE identification Special MEG approved Type Enclosures MM = Mini ModTM ring type R = Type 3R Rainproof MMR = Mini ModTM Ringless Socket rating Horizontal bus rating 12 = 125A 2 = 200A 20 = 200A 4 = 400A 6 = 600A Socket positions 1-6 This presentation contains confidential and proprietary information intended for sole use by ABB or its representatives. ABB reserves all rights in this January 4, 2022 Slide 6 document and in the subject matter and the illustrations contained therein. Any reproduction, disclosure to a third party, or utilization of its contents—in whole or in part—is forbidden without prior written consent from ABB.
— Modular Metering Mini Mod III – Breaker chart 10K 22K 42K 65K 100K Socket size Breaker Breaker Breaker Breaker Breaker 125A THQL THHQL TMQL Use 200A Use 200A sockets sockets 200A TQD (100A to 200A). THQD (100A to 200A). Use 100K Use 100K TMQV1 Use 125A socket for Use 125A socket for under 100A under 100A This presentation contains confidential and proprietary information intended for sole use by ABB or its representatives. ABB reserves all rights in this January 4, 2022 Slide 7 document and in the subject matter and the illustrations contained therein. Any reproduction, disclosure to a third party, or utilization of its contents—in whole or in part—is forbidden without prior written consent from ABB.
— Modular Metering Meter Mod Comprised of: – A main disconnect or service main (main module) – One or more meter stack modules – Tenant Breakers Main service module provides a utility service termination point. Can be main breaker, main fusible switch or main terminal box (MLO – Main Lug Only). Expandable – any number of meter stacks can be ganged together to meet application needs. Each meter socket has provision for a tenant branch breaker. This presentation contains confidential and proprietary information intended for sole use by ABB or its representatives. ABB reserves all rights in this January 4, 2022 Slide 8 document and in the subject matter and the illustrations contained therein. Any reproduction, disclosure to a third party, or utilization of its contents—in whole or in part—is forbidden without prior written consent from ABB.
— Modular Metering Meter Mod layout example (23 Gang) Tenant Main Module Breaker Female end to Male end to expand expand to left to right Meter Stack Modules Three parts 1. Main Module 2. Meter Stack Modules 3. Tenant Breakers (inside meter modules) This presentation contains confidential and proprietary information intended for sole use by ABB or its representatives. ABB reserves all rights in this January 4, 2022 Slide 9 document and in the subject matter and the illustrations contained therein. Any reproduction, disclosure to a third party, or utilization of its contents—in whole or in part—is forbidden without prior written consent from ABB.
— Modular Metering Main breaker module NEC requires a main disconnect and overcurrent protection device ahead of meters when 6 or more branch circuits are used. – A main breaker is a point of disconnect and overcurrent device. – 1-Phase and 3-phase. – 400A, 600A, 800A, 1000A, 1200A, 1400A, 1600A, 2000A. – Single phase has a neutral, A-phase, B-phase, and ground. – Single-phase may be connected to 3-phase bus stacks. – Most popular main disconnect solution. – New NEC 240.87 requires arc reduction means for >=1200A MCB applications Add “AR” to end of Part #. This presentation contains confidential and proprietary information intended for sole use by ABB or its representatives. ABB reserves all rights in this January 4, 2022 Slide 10 document and in the subject matter and the illustrations contained therein. Any reproduction, disclosure to a third party, or utilization of its contents—in whole or in part—is forbidden without prior written consent from ABB.
— Modular Metering Meter Mod III – Nomenclature main modules T MP 3 SB 8 R AR GE identification Additional features AR= Arc Reduction (For >= 1200A main Type breakers only) MP = Meter Mod III CRIS = Copper, Riser Insert for 3-Phase Enclosures Type R = Type 3R Rainproof SB = Main breaker, top/ bottom feed CLL = Compression Lug Landing kit included (400-1200A) ST = Shunt Trip, factory installed SHB = Main breaker, High interrupting, Maximum ampere rating top/ bottom feed (400-1200A) 4 = 400A BB = Main breaker, bottom feed (1400-2000A) 6 = 600A BT = Main breaker, top feed (1400-2000A) 8 = 800A BU = Main breaker with integral pull box – EUSERC 10 = 1000A FT = Main switch, top feed 12 = 1200A FB = Main switch, bottom feed 14 = 1400A L = Main Lug 16 = 1600A U = Main pull box 20 = 2000A This presentation contains confidential and proprietary information intended for sole use by ABB or its representatives. ABB reserves all rights in this January 4, 2022 Slide 11 document and in the subject matter and the illustrations contained therein. Any reproduction, disclosure to a third party, or utilization of its contents—in whole or in part—is forbidden without prior written consent from ABB.
— Modular Metering Meter Mod III – 1PH Main breaker chart Socket size Amperage AIC range Breaker type TMPSB4R 400A 10K – 42K SGH 2P TMPSHB4R 400A >42K – 100K SGL 2P TMPSB6R 600A 10K – 42K SGH 2P TMPSHB6R 600A >42K – 100K SGL 2P TMPSB8R 800A 10K – 65K SKH 2P TMPSB10R 1000A 10K – 65K SKH 2P TMPSB12R 1200A 10K – 65K SKH 2P TMPBB14R (AR), TMPBT14R, 1400A, 10K – 100K RG 2P (Sourced) TMPBB16R (ST or AR), TMPBT16R (ST 1600A or 2000A or AR), TMPBT20R, TMPBB20R (AR) AR suffix = Arc Reduction (meets NEC 240.87) ST suffix = Factory installed shunt trip This presentation contains confidential and proprietary information intended for sole use by ABB or its representatives. ABB reserves all rights in this January 4, 2022 Slide 12 document and in the subject matter and the illustrations contained therein. Any reproduction, disclosure to a third party, or utilization of its contents—in whole or in part—is forbidden without prior written consent from ABB.
— Modular Metering Meter Mod III – 3PH Main breaker chart Socket size Amp rating AIC range Breaker type TMP3SB4R 400A 10K – 42K SGH 3P TMP3SHB4R 400A >42K – 100K SGL 3P TMP3SB6R 600A 10K – 42K SGH 3P TMP3SHB6R 600A >42K – 100K SGL 3P TMP3SB8R 800A 10K – 65K SKH 3P TMP3SB10R 1000A 10K – 65K SKH 3P TMP3SB12R 1200A 10K – 65K SKH 3P TMP3BB14R (AR), TMP3BT14R (AR), 1400A, 10K – 100K RG 3P (Sourced) TMP3BB16R (CLL, AR or ST) 1600A or 2000A TMP3BT16R (ST or AR), TMP3BT20R (ST or AR), TMP3BB20R (CLL, AR or ST) AR suffix = Arc Reduction (meets NEC 240.87) CLL suffix = EUSERC rated unit ST suffix = Factory installed shunt trip This presentation contains confidential and proprietary information intended for sole use by ABB or its representatives. ABB reserves all rights in this January 4, 2022 Slide 13 document and in the subject matter and the illustrations contained therein. Any reproduction, disclosure to a third party, or utilization of its contents—in whole or in part—is forbidden without prior written consent from ABB.
— Modular Metering Main modules – Center feeding SUITABLE FOR CENTER-FEED APPLICATIONS ONLY* *Example of rating label for 1200A meter modules: Horizontal bus is rated 1200 amps maximum. The load on the horizontal bus may not exceed 1200 amps in either direction from the point of connection of the main circuit breaker. Overall load is limited to the rating of the main circuit breaker. For applications where the main module ampere is greater than that of the meter stack horizontal bus, the main module must be placed in the middle of the lineup (Figure A, next slide). The engineer of record must provide calculations showing that the horizontal bussing will not be overloaded on either side. This situation (called “Center-Feeding”) can happen in either 800A or 1200A horizontal bus meter stack applications, depending on the main ampere rating. Refer to the chart (next slide) for amperage and bus information. Note: Figures B & C (next slide) show examples of incorrect meter stack configurations. This presentation contains confidential and proprietary information intended for sole use by ABB or its representatives. ABB reserves all rights in this January 4, 2022 Slide 14 document and in the subject matter and the illustrations contained therein. Any reproduction, disclosure to a third party, or utilization of its contents—in whole or in part—is forbidden without prior written consent from ABB.
— Modular Metering Main modules – Center feeding (Cont.) Does my application require me to center-feed my main module? Amps of main breaker, lug or switch 800A horizontal bus 1200 horizontal bus 400A – 800A No No 1000A Yes No 1200A Yes No 1400A Yes Yes 1600A Yes Yes 2000A Yes Yes Main Main Main Correct Incorrect Incorrect This configuration is centered and This configuration will overload the This configuration will overload the will balance the load between left and left-side horizontal bus that leaves the right-side horizontal bus that leaves the right-side horizontal bus leaving the main section main section main section Figure A Figure B Figure C This presentation contains confidential and proprietary information intended for sole use by ABB or its representatives. ABB reserves all rights in this January 4, 2022 Slide 15 document and in the subject matter and the illustrations contained therein. Any reproduction, disclosure to a third party, or utilization of its contents—in whole or in part—is forbidden without prior written consent from ABB.
— Modular Metering Main modules Fusible switch NEC requires a main disconnect and overcurrent protection device ahead of meters when 6 or more branch circuits are used. – A fusible main switch is a point of disconnect and overcurrent device. – 1-Phase and 3-phase. – 400A, 600A, 800A, 1200A, 1600A, 2000A. – Single phase has a neutral, A-phase, B-phase, and ground. – Single-phase may be connected to 3-phase bus stacks. – Fuses not included. This presentation contains confidential and proprietary information intended for sole use by ABB or its representatives. ABB reserves all rights in this January 4, 2022 Slide 16 document and in the subject matter and the illustrations contained therein. Any reproduction, disclosure to a third party, or utilization of its contents—in whole or in part—is forbidden without prior written consent from ABB.
— Modular Metering Main modules Terminal box (Main lug) – 1-phase and 3-phase. – 400A, 600A, 800A, 1200A, 1600A. – Lugs included. – Also have feed-thru lug options for 1200A & 1600A (add CRIS to part #). This presentation contains confidential and proprietary information intended for sole use by ABB or its representatives. ABB reserves all rights in this January 4, 2022 Slide 17 document and in the subject matter and the illustrations contained therein. Any reproduction, disclosure to a third party, or utilization of its contents—in whole or in part—is forbidden without prior written consent from ABB.
— Modular Metering Main modules Pull box A main pull box provides an Electrical Utility with a place to terminate incoming cables without having to access and work inside a customer main disconnect. – 1-phase and 3-phase. – 400A, 800A, 1200A. – Lugs included. – No cross bus. This presentation contains confidential and proprietary information intended for sole use by ABB or its representatives. ABB reserves all rights in this January 4, 2022 Slide 18 document and in the subject matter and the illustrations contained therein. Any reproduction, disclosure to a third party, or utilization of its contents—in whole or in part—is forbidden without prior written consent from ABB.
— Modular Metering Meter Mod III – Nomenclature meter stacks Product number guide for meter stack modules – (Product number for illustrative purposes only) T MP 3 8 6 20 T R F GE identification Special MEG approved Type Enclosures MP = Meter ModTM ring type R = Type 3R Rainproof MPR = Meter ModTM Ringless MPK = Meter Mod K-Base socket Insert for tenant breakers Socket rating 12 = 125A Insert for 3-Phase 20 = 200A 22 = 225A 40 = 400A Horizontal bus rating 8 = 800A Socket Positions 12 = 1200A 1-6 This presentation contains confidential and proprietary information intended for sole use by ABB or its representatives. ABB reserves all rights in this January 4, 2022 Slide 19 document and in the subject matter and the illustrations contained therein. Any reproduction, disclosure to a third party, or utilization of its contents—in whole or in part—is forbidden without prior written consent from ABB.
— Modular Metering Residential meter stack/ module (125 & 200A) 1. Solid Meter Barrier accomplished for the AC and BC phases by moving Barrel-shaped 8 Meter socket and main tenant breaker/ wireway sections are and Z-shaped phase connectors on two-thirds of the other meter separated by solid meter barrier to protect against power theft and stacks 1 improve safety 8. Raintight Cap 2. Tenant Breakers Shipped for each meter stack module and main device. 2 Reliable connection directly to the bus bars. 125A 13 9. Knockouts modules allow plug-in breakers (15-125A). 200A Included in the bottom endwall modules allow bolt-on breakers 60-200A 10 10. Meter Socket 6 3. Neutral Assembly Meter socket base installed without any fasteners which reduces hot A convenient termination for neutral conductors that is in the spots, makes it easily replaceable and improves connections to wireway of each meter stack module vertical bussing 4. Enclosed Horizontal Bus 11. Bus Connection Non-removable barrier encloses the 800A or 1200A horizontal bus 7 3 Mains and Meter Modules slip together quickly and smoothly with passing through tenant breaker section. This provides added front-accessible captive bolts securing 4 security and protection the two sections without removing interiors or 5. Equipment Ground Bar bus access plates. Main bus joint bolts torque to 25 ft. lbs. 11 Factory installed in the side gutter which is a standard feature that is 12. Separate Wireway Cover moveable to top or bottom of the gutter Separate covers allow easy access to tenant breaker and wireway 6. Superior Finish sections permitting work on breakers or in wireway without Rush inhibiting phosphate primer and gray baked enable are disturbing the meters or meter covers (not shown) standard on the modules. All outdoor enclosures have galvanized 13. Vertical Bus Bar steel construction to improve rigidity One-piece vertical bus bar from phase balancing joints to meter 7. Moveable Phase Balancing Connectors socket eliminating any change of hot spots Four-wire horizontal bussing allows you to use any residential 5 module for 1PH or 3PH incoming service. Shipped with A & B phase connection from factory, field phase balancing can be easily 9 This presentation contains confidential and proprietary information intended for sole use by ABB or its representatives. ABB reserves all rights in this January 4, 2022 Slide 20 document and in the subject matter and the illustrations contained therein. Any reproduction, disclosure to a third party, or utilization of its contents—in whole or in part—is forbidden without prior written consent from ABB.
— Modular Metering Commercial meter stack/ module (225A) 1. End Walls 7. Neutral Assembly Top cap is removable and does not contain knockouts so Located in the wireway of each module, the assembly permits 10 contractors can position and punch holes where needed. Numerous convenient termination of the neutral conductors KO’s in the back and bottom are included for flexibility 8. Enclosed Horizontal Bus 2. Meter Socket Non-removable metal barrier encloses 1200A horizontal bus when 9 The 5-Jaw and 7-jaw meter sockets include a built-in lever bypass passing through tenant breaker section which adds security and jaw release. The ground wire is factory connected. 9. Tenant Breaker Range 3. Ground Bars All modules accept 15-225A bolt-on breakers up to 100K interrupting 4 The factory-installed equipment ground bars are provided in both rating. The breakers are UL listed for series rating with the breakers top and bottom gutters in GE load centers and panels 4. Barrier 10. Indoor/ Outdoor Construction 7 A solid metal barrier separates the meter socket section from tenant Raintight caps, meter covers and lockable raintight tenant breaker breaker in wireway section. The unmetered vertical bus is enclosed covers make it convenient for you to use any of our meter modules to guard against power theft for N1 or N3R applications 2 12 5. Separate Wireway Cover 11. Nameplate and Ratings If work on breakers or cables is needed, it can be accomplished Nameplate gives you full rating data: 8 without disturbing meters or meter covers. The wireway cover 208Y/120, 3PH4W; 240/120V 3PH4W; 120/240V 3PH4W delta (high allows easy access to the module’s tenant breaker and wireway leg on B phase); and 120/240V 1PH (not shown) section (not shown) 12. Mains and Modules 6. Mounting Rail Connect together quickly and smoothly with front-accessible bolts Rear mounting rail and wall hanger speed and simplify installation securing them without removing socket interiors or bus access (not shown) plates. Main bus joint bolts torque to 25 ft. lbs. 3 1 This presentation contains confidential and proprietary information intended for sole use by ABB or its representatives. ABB reserves all rights in this January 4, 2022 Slide 21 document and in the subject matter and the illustrations contained therein. Any reproduction, disclosure to a third party, or utilization of its contents—in whole or in part—is forbidden without prior written consent from ABB.
— Modular Metering Commercial meter stack/ module (400A) Rain cover 16 gauge Spectra SG breaker Meter socket 400A Wired seventh jaw can be moved to3 o’clock position 1200A aluminum bus (bus cap not provided) Rating plug Knockouts Not a removable plate Includes (1) SGH breaker (1 High Stacks) Includes (2) SGH breakers (2 High Stacks) Lever bypass handle Only Lever Bypass option This presentation contains confidential and proprietary information intended for sole use by ABB or its representatives. ABB reserves all rights in this January 4, 2022 Slide 22 document and in the subject matter and the illustrations contained therein. Any reproduction, disclosure to a third party, or utilization of its contents—in whole or in part—is forbidden without prior written consent from ABB.
— Modular Metering Socket types for meter stacks/ modules Standard socket (non-bypass) Horns Lever bypass socket Horn bypass socket Allows you to bypass the meter with Allows you to bypass the meter with a lever. Safest option to achieve a jumper. Not as safe as lever bypass bypass but more expensive but less expensive in most cases Local utility will decide the socket standard they want to use for your area This presentation contains confidential and proprietary information intended for sole use by ABB or its representatives. ABB reserves all rights in this January 4, 2022 Slide 23 document and in the subject matter and the illustrations contained therein. Any reproduction, disclosure to a third party, or utilization of its contents—in whole or in part—is forbidden without prior written consent from ABB.
— Mebane LIVE 2021 Modular Metering Meter stack/ Module phase balancing All three-phase meter stack modules come 125A stacks Figure A Figure B factory connected to phase A and B, per figure “Barrel” shaped “Barrel” shaped A. When connected to a 208Y/120 Vac phase connector phase connector 3-phase, 4-wire system, field phase balancing of two out of every three stacks is required. Factory 125A A-C phasing Field 125A C-B phasing One of every three stacks should be phased Remove “Z” phase connector Remove “Barrel” phase AC, per figure B, and one of every three stacks from “B” phase horizontal bus connector from “A” phase should be phased CB, per figure C. Replace with “Barrel” phase Horizontal bus Examples: connector supplied with Reattached at “C” phase – 9 Total positions – Use (3) 3-position meter stack and attach to “C” horizontal bus as shown. stacks and phase one per figure B phase bus as shown. Torque to 60 lb in (A-C phasing) and one per figure “Z” shaped “Barrel” shaped Torque to 60 lb-in (6.78 N-M) “Barrel” shaped “Z” shaped (6.78 N-M) C (C-B) phasing phase connector phase connector Retain “Z” phase connector phase connector phase connector – 16 Total positions – Use (2) 5-position and for future use. (2) 3-position stacks. Phase balance Factory 125A A-B phasing (1) 5-position per figure B (A-C phasing) and (1) 5-position per figure C (C-B phasing) 200A stacks – 19 Total positions – Where 4 position “Barrel” shaped “Barrel” shaped maximum height is allowed by utility, phase connector phase connector use(1) 4-position and (5) 3-position stacks. Phase balance (2) 3-position Factory 200A A-C phasing Factory 200A C-B phasing stacks per figure B (A-C phasing and Remove “Z” phase connector Remove “Barrel” phase (2) e-position stacks per figure C from “B” phase connector from “A” phase (C-B)phasing Horizontal bus Horizontal bus Reattached at “C” phase Reattached at “C” phase horizontal bus as shown horizontal bus as shown. Torque to 60 lb-in (6.78 N-M) Torque to 60 lb in (6.78 N-M) “Z” shaped phase connector “Z” shaped “Barrel” shaped “Z” shaped “Z” shaped “Barrel” shaped phase Factory 200A A-B phasing phase connector phase connector phase connector phase connector connector “Z” shaped and “Barrel” shaped phase connectors Only required for3PH incoming to 1PH outgoing applications This presentation contains confidential and proprietary information intended for sole use by ABB or its representatives. ABB reserves all rights in this January 4, 2022 Slide 24 document and in the subject matter and the illustrations contained therein. Any reproduction, disclosure to a third party, or utilization of its contents—in whole or in part—is forbidden without prior written consent from ABB.
— Modular Metering Meter Mod III – Tenant breaker chart 10K 22K 42K 65K 100K Socket size breaker breaker breaker breaker breaker Use 200A Use 200A 125A THQL THHQL TMQL sockets sockets 200A TQD THQD Use 100K Use 100K TMQV1 TEB (15-90A); THQD 225A TQD (100-200A); (100-200A); TMQV1 Use 100K Use 100K TMQV1 TMQV1 (225A) (225A) SGH breaker SGH breaker SGH breaker SGH breaker 400A included included included included No current option w/ stack w/ stack w/ stack w/ stack This presentation contains confidential and proprietary information intended for sole use by ABB or its representatives. ABB reserves all rights in this January 4, 2022 Slide 25 document and in the subject matter and the illustrations contained therein. Any reproduction, disclosure to a third party, or utilization of its contents—in whole or in part—is forbidden without prior written consent from ABB.
— Modular Metering Value added resources for modular metering – New multi-family brochures (DET-843 & DET-838) – New application and stock selection guides (DET-860, DET-848, DET-856) – BIM files available on publication library (end of Sept 2016) for all meter stacks and mains. Helps with consultants/ end users This presentation contains confidential and proprietary information intended for sole use by ABB or its representatives. ABB reserves all rights in this January 4, 2022 Slide 26 document and in the subject matter and the illustrations contained therein. Any reproduction, disclosure to a third party, or utilization of its contents—in whole or in part—is forbidden without prior written consent from ABB.
— Single Socket Metering Single socket metering overview Features Picture Single meter socket with enclosure (600V rated) So far complete product solutions for 4 major utilities (more to come) 1. Kansas City Power & Light (KCP&L) – Kansas City metro area 2. Detroit Edison (DTE) – Michigan area 3. Meter Equipment Group (MEG) – FL, OK, NC, SC, OH, KY and IN 4. American Electric Power (AEP) – AR,IN,KY,LA,MI,OH,OK,TN,TX,VA & WV Amp ratings from 20A – 320A Picture This presentation contains confidential and proprietary information intended for sole use by ABB or its representatives. ABB reserves all rights in this January 4, 2022 Slide 27 document and in the subject matter and the illustrations contained therein. Any reproduction, disclosure to a third party, or utilization of its contents—in whole or in part—is forbidden without prior written consent from ABB.
— Horizontal Metering Horizontal metering overview Features Picture 2-6 meter sockets in one horizontal enclosure (600V rated) 4 major utilities completed (more to come) 1. Kansas City Power & Light (KCP&L) – Kansas City metro area 2. Detroit Edison (DTE) – Michigan area 3. Meter Equipment Group (MEG) – FL, OK, NC, SC, OH, KY and IN 4. American Electric Power (AEP) – AR,IN,KY,LA,MI,OH,OK,TN,TX,VA & WV Amp ratings from 100A - 200A per socket This presentation contains confidential and proprietary information intended for sole use by ABB or its representatives. ABB reserves all rights in this January 4, 2022 Slide 28 document and in the subject matter and the illustrations contained therein. Any reproduction, disclosure to a third party, or utilization of its contents—in whole or in part—is forbidden without prior written consent from ABB.
Thanks for your business. January 4, 2022 Slide 29
— Find out more at electrification.us.abb.com This presentation contains confidential and proprietary information intended for sole use by ABB or its representatives. ABB reserves all rights in this January 4, 2022 Slide 30 document and in the subject matter and the illustrations contained therein. Any reproduction, disclosure to a third party, or utilization of its contents—in whole or in part—is forbidden without prior written consent from ABB.