Jammu and Kashmir Notice Inviting Tender Fabrication , Supply , Carriage and Installation of Prefabricated Dormitories at Lower Holy Cave 02 ...

Page created by Jeanette Hoffman
 
CONTINUE READING
Jammu and Kashmir Notice Inviting Tender Fabrication , Supply , Carriage and Installation of Prefabricated Dormitories at Lower Holy Cave 02 ...
Jammu and Kashmir
              Notice Inviting Tender
      Fabrication , Supply , Carriage and
  Installation of Prefabricated Dormitories at
         Lower Holy Cave (02 Nos.) and
               Brarimarg(01 No.)
                       for
                   Yatra - 2021
                                  Sd/-
                            Addl. Chief Executive Officer,
                             Shri Amarnathji Shrine Board

Dated 15.03.2021

                                                         Page 1
TENDER DOCUMENT FOR THE WORK OF FABRICATION, SUPPLY , CARRIAGE AND
    INSTALLATION OF DORMITORIES AT LOWER HOLY CAVE(02 Nos.) AND
                       BRARIMARG (01 No.) FOR
                           YATRA - 2021.

                 DETAILED NOTICE INVITING TENDER (DNIT)

     (issued under no. SASB/NIT/W/2021/1289/24      dated 15.03.2021)

 #                           CONTENT                          PAGE(S)

 1    Notice Inviting Tender (NIT) for advertisement               3

 2    Eligibility Criteria                                         4

 3    Documents Establishing Bidder’s Eligibility                  4

 4    Instructions to Bidders                                     5-7

 5    Job Description                                             8-11

 6    Conditions of Contract                                     12-20

 7    Schedule – A (Technical Bid)                               21-24

      Annexure-A - Performance Statement Form                      25

      Annexure-B - Compliance Statement of                         26
                   Specifications

 8    Schedule – B (Financial Bid)                               27-40

 9    Drawing                                                      41

                                                                         Page 2
SHRI AMARNATHJI SHRINE BOARD
                                 (Established under an Act of J&K State Legislature)
                                   Chaitanya Ashram, Talab Tillo, Jammu (Nov-April)
                                      Tele: 0191-2569910, Telefax: 0191-2503399
                                        NOTICE INVITING TENDER
                  FABRICATION, SUPPLY, CARRIAGE AND INSTALLATION OF DORMITORIES AT
                          LOWER HOLY CAVE AND BRARIMARG FOR YATRA - 2021

     For and on behalf of Chairman, Shri Amarnathji Shrine Board, sealed tenders in two-bid format are
     invited from reputed and experienced SSI Unit holders / Micro Small & Medium Entrepreneurs
     having valid Registration from District Industries Centre, for the below mentioned works. The Bids
     shall be received in the Office of General Manager (Works), Shri Amarnathji Shrine Board,
     Chaitanya Ashram, Talab Tillo, Jammu on or before 05.04.2021 upto 1400 hours.
       S.    Name of work                      Estimated Cost            of      Earnest       Last    date
       No                                      Cost          Tender            Money/ Bid for
                                               (in Lakhs) Document               Security      Submission
                                                             (in Rs)          (in Rs)          of Bids
       1.    i)   Fabrication,       Supply,      40.48      Rs.4000/-        80960.00
             Carriage and Installation of
             02 Nos. Dormitories at
             Lower Holy Cave for Yatra -
             2021.
             ii)  Annual      Maintenance                                                      05.04.2021
             Contract for a period of 05            -                                          Upto1400
             years post warranty period                                                        hours.
             of one year.
       2.    i)   Fabrication,       Supply,      19.90      Rs.2000/-        39800.00
             Carriage and Installation of
             01    No.     Dormitory       at
             Brarimarg for Yatra - 2021.
             ii)  Annual      Maintenance            -
             Contract for a period of 05
             years post warranty period
             of one year.
2.   DNIT can be obtained from the Office of FA/ Chief Accounts Officer, Shri Amarnathji Shrine Board,
     (address mentioned above) from 15.03.2021 to 01.04.2021 on any working day during office hours
     on payment shown against each work, in cash or in the shape of Demand Draft in favour of FA/
     Chief Accounts Officer, Shri Amarnathji Shrine Board (SASB), Jammu. Alternatively, the DNIT can
     be downloaded from SASB website www.shriamarnathjishrine.com,
3.   The Tenders, duly completed, along with Earnest Money Deposit must reach the office of General
     Manager (Works) latest by 05.04.2021 (1400 hours.) The bidder, in his own interest, is advised to
     deliver the bids personally to General Manger (Works), Shri Amarnathji Shrine Board, Chaitanya
     Ashram, Talab Tillo, Jammu. Alternatively, he may send the same through Speed Post/
     Registered Post. The Board will not be responsible for any delay, wrong delivery or non-delivery of
     the bids due to any reasons thereof.
4.   In case the last date of receipt of bid happens to be a holiday, the bid shall be received on the next
     working day up to 1400 hours.
5.   The Technical bids shall be opened on 05.04.2021 at 1500 hours in the office of Additional Chief
     Executive Officer, (at Jammu Office; address mentioned above) in presence of the bidders who may
     wish to be present on the occasion.
6.   All subsequent information/ Corrigendum/ Addendum/ Updates shall be uploaded on SASB website
     only, therefore, the bidders are requested to visit the website regularly for latest updates.
7.   The successful bidder is bound to enter into an agreement with SASB, within fifteen days from the
     date of the receipt of Letter of Intent.
 No: SASB/NIT/W/2021/1289/24                                                        Sd/-
 Dated: 15.03.2021                                                        Addl. Chief Executive Officer
                                                                            Shri Amarnathji Shrine Board

                                                                                                              Page 3
2.     ELIGIBILITY REQUIREMENT

2.1 The Bidder must be a registered Micro, Small or Medium Enterprise,
    with Government of Jammu and Kashmir, District Industries Centre.

2.2     Consortium or a Joint Venture in any form shall not be eligible for bidding.

2.3     Average annual turnover during the last three years, ending 31st March of the
       previous financial year (i.e. 2017-18, 2018-19, 2019-20), should be equal to 30%
       of the estimated amount of the work.

2.4 The Company/ Society/ Firm should have an experience of having successfully
    completed during the past seven years (design, fabrication, supply, testing and
    installation of prefab huts) ending last day of month previous to the one in which
    applications are invited should be either of the following:-

       a. Three similar completed works costing not less than the amount equal to 40% of
          the estimated cost of each work.
                                              Or
        b. Two similar completed works costing not less than the amount equal to 50% of
            the estimated cost of each work.
                                              Or
       c. One similar completed work costing not less than the amount equal to 80% of the
          estimated cost.

 2.5 The Bidder should not have been blacklisted on previous occasion by any of the
 Central/ Union Territory Government Organizations, Statutory Central/ U.T.
 Autonomous Bodies, Central/ U.T. Public Sector Undertakings, Central/ U.T.
 Government owned Hospitals or Local Bodies/ Municipalities.

     3. DOCUMENTS ESTABLISHING BIDDER’S ELIGIBILITY

3.1    Registration Certificate from any District Industries Centre of Jammu and
       Kashmir.
3.2    List of present Directors/ Owners/ Executive Council Members/ Board Members,
     as applicable.
3.3 Certified copies of:

         a)    Income tax returns of 2017-18, 2018-19, 2019-20. Bidder shall also submit
              proof of PAN

         b)   Audited Balance Sheet 2017-18, 2018-19, 2019-20.

         b) Audited Income and Expenditure Statement 2017-18, 2018-19, 2019-20.

                                                                                       Page 4
3.4            Certified documents like Letter of Award, Work Order, Certificate of
         Completion etc. indicating experience and successful execution of similar works, for
         fulfilling the eligibility criteria.

   3.5 Certified copy of PAN Card.
   3.6 Certified Copy of GSTIN.
   3.7 General Power of Attorney/ Board of Directors Resolution/ Deed of Authority
executed in favour of person(s) authorized to sign the Tender Document and the Contract
and all correspondences/ documents thereof.
   3.8 General information/ Profile of the Bidder.

  3.9 An affidavit by the Bidder, on Rs. 100 e-stamp paper, stating that every information
      furnished in the Tender Document is correct and to the best of his knowledge and
      that no criminal/ income tax/ blacklisting case is pending against him. If any
      information is found to be incorrect at any time, the Security Deposit is liable to be
      forfeited without any notice.
4 INSTRUCTIONS TO BIDDERS:
         Sealed Bids in Two-Bid Format are hereby invited from original Equipment
         Manufacturers for the Fabrication,Supply, Carriage and Installation of Dormitories at
         Lower Holy Cave and Brarimarg for Yatra - 2021 (for details of these locations,
         please read Scope of Work).

    4.1 Detailed NIT (DNIT) can be obtained from the office of FA/ Chief Accounts Officer,
        Shri Amarnathji Shrine Board, Chaitanya Ashram, Talab Tillo, Jammu from
        15.03.2021 to 01.04.2021 on any working day (Monday-Friday) during office hours
        on payment shown in the DNIT against the work in cash or in the shape of Demand
        Draft in favour of FA/ CAO, Shri Amarnathji Shrine Board (SASB), Jammu.
        Alternatively, the DNIT can be downloaded from SASB website
        www.shriamarnathjishrine.com, in which case the cost of DNIT shall be payable.

    4.2 The Tenderers are required to submit two separate Bids i.e. – Technical and
        Financial, as per format given in Schedule A and Schedule B of the DNIT
        respectively. The two Bids should be submitted in two separately sealed envelopes
        super-scribed “Technical Bid for ___________________________________”
        and “Financial Bid for fabrication __________________________________”.
        Both the sealed envelopes should be put in a third envelop, sealed and super-
        scribed “Tender for _________________________________________________
        – Yatra 2021”. The bids shall be submitted as per format prescribed in Schedule
        A and Schedule B only.
    4.3 The bids, duly completed, along with Earnest Money Deposit must be dropped in
        the Tender Box kept in the office chamber of General Manager (Works), Shri
        Amarnathji Shrine Board, Chaitanya Ashram, Talab Tillo, Jammu or sent by
        Registered Speed Post to General Manager (Works), SASB at the aforesaid
        address, so as to reach latest by 05.04.2021 (1400 hours). Bids received after the
        aforesaid date and time will not be considered. The Shrine Board shall not be
        responsible for any delay/ loss of documents or correspondence sent by speed
        post.

                                                                                      Page 5
4.4 The Bidder shall bear all costs associated with the preparation and submission of
    his bid and the SASB will, under in no case, be responsible for those costs,
    regardless of the conduct or outcome of the bidding process.
4.5 The Bidder is expected to examine all Instructions, Schedules, Formats, Terms and
    Conditions, Scope of Work mentioned in the DNIT. Failure to furnish all relevant
    information as prescribed in the Tender Document or submission of Tender not
    substantially responsive to the Tender Document in every respect will be at Bidder’s
    risk and may result in the rejection of the bid.
4.6 All entries in the Technical/ Financial Bids should be legible and should be free from
    corrections/ erasures/ overwriting/ cuttings. Bids with corrections/ erasures/
    overwriting/ cuttings shall be out rightly rejected. Amounts shall be indicated in
    words as well as in figures. In case of any variation between amount in figures and
    words, amount quoted in words shall be taken as authentic.
4.7 The rate quoted should be inclusive of all taxes including GSTIN.
4.8 The rate quoted by the Contractor in item tenders shall be on correct basis and not
    the amount worked out by them. The rate quoted in words will be correct basis and
    not the rate shown in figures in case of discrepancy between them.
4.9 Any tender which stipulates any alteration to any of the conditions laid down or
    which proposes any other condition of any description whatsoever is liable to be
    rejected.
4.10 The Bidder must satisfy himself that it fulfils all the prescribed eligibility conditions
    to avoid rejection of its bid.

4.11 Each paper of the Tender document shall be completed in all respects, page
     numbered, and duly signed in long hand, executed in ink and stamped at the
     bottom right hand corner by an authorized/ empowered representative of the
     Bidder. The Bidder must also sign and stamp all pages of this DNIT as acceptance
     of all conditions contained therein and for the purpose of identifications. Financial
     Bid received in the format other than specified in Schedule B (Financial Bid) is
     liable to be rejected.

4.12 Bids must be received at the address specified above not later than the date and
     time stipulated in this DNIT. The CEO, SASB may, at his discretion, extend the
     deadline for submission of bids. Any bid received after the deadline for submission
     of bids, as stipulated above, shall not be considered and will be returned.

4.13 The Bidder shall quote relevant National/ International Code of the parts, along
     with manufacturer’s Name, Trade Mark or Patent No., if any, used in construction
     of prefab huts.

4.14 Clarifications on DNIT, if any, may be sought by the bidders so as to reach CEO/
     Addl. CEO at least seven days before last date prescribed for submission of bids.
     Except for any written clarification by CEO/ Addl. CEO, SASB which is expressly
     stated to be an addendum to the DNIT, no written or oral communication,
     presentation or explanation by any other employee of the SASB shall be taken to
     bind or fetter the Shrine Board under the Contract. All corrigenda, addenda,
     amendments and clarifications to the DNIT will be hosted on our webpage

                                                                                      Page 6
(www.shriamarnathjishrine.com) and NOT in the newspaper. Bidders shall keep
     themselves updated on this account.
4.15 The Technical Bid shall be opened on 05.04.2021 at 1500 hours in the office of
     the Additional Chief Executive Officer, SASB, Chaitanya Ashram Talab Tillo,
     Jammu in the presence of the authorized representatives of the firms who may
     wish to be present at that time. Bidders whose Technical Bids have been accepted
     shall be informed about the date and time for opening of the Financial Bids.
4.16 The CEO, SASB is not bound to accept the lowest or any bid and may, at any time
     by notice in writing to the bidders, terminate the tender process without assigning
     any reason whatsoever.
4.17 The Tender shall remain valid and open for acceptance for a period of 60 days
     from the last date of receipt of tender.
4.18 The CEO/ Addl. CEO, SASB shall award the Contract to the successful bidder
     whose bid has been found to be responsive and who is eligible and qualified to
     perform the Contract satisfactorily as per Terms and Conditions incorporated in
     the DNIT. The CEO/ Addl. CEO, SASB will communicate the successful bidder
     through Registered Post that his bid has been accepted. This letter (hereinafter
     referred to as the ‘Letter of Intent’) shall prescribe the amount which the Shrine
     Board will pay to the Contractor in consideration of work/ services to be executed
     by the Contractor as prescribed in the Contract.
4.19 The successful Bidder shall be required to furnish a Performance Security Deposit
     within ten days of receipt of ‘Letter of Intent’ equal to 5% of the total value of the
     Contract, in the form of CDR/ FDR in favour of FA & Chief Accounts Officer,
     SASB. In case the eligible Bidder fails to submit the Performance Security
     Deposit of the requisite amount within the stipulated period, the ‘Letter of Intent’ is
     liable to be withdrawn and the EMD (if deposited) is liable to be forfeited, at the
     discretion of the CEO,Shri Amarnathji Shrine Board.
4.20 The eligible bidder after furnishing the prescribed Performance Security Deposit
     (PSD) will have to enter into an Agreement with the Shrine Board as per the
     Terms and Conditions mentioned in the DNIT or such other terms that may be
     prescribed, within a period of fifteen days from the date of receipt of ‘Letter of
     Intent’.
4.21 The Chief Executive Officer, SASB reserves the right to reject all or any Tender in
     whole, or in part, without assigning any reason. Any enquiry after the submission
     of Bid will not be entertained.

4.22 A pre-bid Conference will be held on 26.03.2021 at 1100 hours in the office
     chamber of Addl. CEO, SASB. The prospective bidders may contact the office of
     General Manager (Works) on 0191 - 2555662 to register themselves for the pre-
     bid Conference up to 24.03.2021.

                                                                   Sd/-
                                                             Addl. Chief Executive Officer,
                                                               Shri Amarnathji Shrine Board

                                                                                    Page 7
5. Job Description
(i) Fabrication, Supply, Carriage and Installation of Dormitories of size18.00 meter x
5.30with Verandah 3.00mx1.50m at:
a) (02 Nos) at Lower Holy Cave
b) (01 No.) at Brarimarg.
(ii) The specifications of the 01 No. Dormitory would be as given below:

S.No Component       Approximate Quantity             Specifications/Description
01    Structural     i.    Column                     The structural members shall be designed for the
      Steel                post:100x100x4.0mm     =   below given conditions:
                           1116.70 Kg                    (a) Seismic – Zone V
                     ii. Truss:80x40x4.0mm=              (b) Wind speed – 55 m/s (As per IS-
                           1422.79 Kg                                        875)
                     iii. Purlins                        (c) Snow Load – 1 meter standing on
                           :49.5x49.5x3.6mm=                  roof
                           946.56 Kg                     (c) Temperature Range (-) 25 degree
                     Total= 3486.00 Kg                                       C to (+) 30 degree C.
                     i. U-Channel(3mm                 The min requirement of various structural
                           thick):80x50x3mm=          members are as under mentioned
                           507.61 Kg                     (a)    Truss. Eight trusses , made of
                     ii. Base Plate and Top Plate              rectangular tubular steel sections of size
                           with      Gusset   Plate            80 mm x 40 mm, 4.0 mm conforming to
                           :200x200x12.00mm       =            IS 4923:1997 shall be provided. Base
                           241.28 Kg                           plate welded to the truss on either side of
                          :150x150x10.00mm        =            min size 150 mm x150 mm. 10 mm thick
                           164.50 Kg                           with 04 pre drilled holes of appropriate
                     iii. M.S                Cleats            sizes to accommodate heavy duty G.I
                           :100x60x5.0mm=                      bolts of appropriate dimensions with nuts
                           30.24 Kg                            with GI and bitumen Washer with each
                     iv. Foundation           Bolts            truss.
                           :20x450mm =                   (b) Purlins. Purlins made of square tubular
                           204.00 Kg                           steel sections of size 49.5 mm x 49.5
                     v. Other Nuts & Bolts(L.S)                mm, 3.6 mm thick weighing 4.93 kg/m
                           = 50.00 Kg                          conforming to IS 4923:1997 alongwith 02
                     Total                        =            Nos. cleats of MS cleat of min size 80
                     1198.00 Kg                                mmx120mm, 5 mm thick continuously
                                                               welded on both ends of the Purlin duly
                                                               drilled of 02 holes for bolts of appropriate
                                                               dimensions for fixing of purlin with truss.
                                                         (c) Columns. Column shall be made of
                                                               tubular section of size 100x100x4mm,
                                                               both ends welded with M.S plate of size
                                                               200x200x12 mm at bottom and
                                                               150x150x10mm at top. M.S plates shall
                                                               have 04 No of pre drilled holes for fixing
                                                               with truss using fasteners of appropriate
                                                               size. Foundation bolts shall be min dia 20
                                                               mm and length 45 cm and foundation bolt
                                                               plate of size 200x200x12mm with 04 No.
                                                               predrilled holes at appropriate place.

                                                                                                   Page 8
02   Walling   &         186.47 Sqm              The wall panels shall be 80 mm thick made up of
     Gable                                       79 mm thick polyurethane foam (PUF) as
                                                 insulation sandwiched between 0.5 mm thick
                                                 grey/cream colored Pre-Painted Galvanized Iron
                                                 (PPGI) sheets (ribbed type for all panels, joints
                                                 angles, tracks,-design of ribbing shall be
                                                 manufacture’s own). PUF used shall be CFC free
                                                 and of density 40 kg+/-2 kg/cum and shall conform
                                                 to IS 12436/19889 reaffirmed 2011. The wall PUF
                                                 panel will be provided with tongue and groove
                                                 arrangement/shall be interlocked using cam locks
                                                 system. Gable ends will also be covered with
                                                 same panels as of wall. All materials required for
                                                 the manufacture of shelter will be new and shall
                                                 comply with relevant Bureau of Indian Standards
                                                 Specifications. The PUF insulation material in the
                                                 panel will have fire retarding and self extinguishing
                                                 properties as per international standard B2 DIN
                                                 410part/BS-4735 Self Ext. The wall panel at the
                                                 top and bottom corners will be joined by U-channel
                                                 80x50x3mm. Since all the flashings are of PPGI no
                                                 welding will be allowed. The PPGI angle and
                                                 flashings are to be bended or /& riveted to from the
                                                 desired shape and size.
                                                 Make: Jindal Mectec/E Pack Polymer/Modern
                                                 Prefab Systems
03   Roofing and      a) Roofing-131.22 sqm      The roof shall be provided with 30/70mm thick
     its              b) Ridges plain (500 -     PUF panel (polyurethane foam conforming to IS
     Accessories         600mm) – 18.30 Rm       12436:1988 and PPGI sheet conforming to IS
                      c) Bird Cover (300 mm) -   14246:2013 for yield strength and IS 277:2018 for
                         36.60Rm                 zinc coating , sheet shall have 5-7 micron epoxy
                      d) Eaves                   primer on both sides and polyester top coat of 15-
                         Boarding/Barge          18 micron .Also, sheet shall have guard film of 25
                         Board(upto 300mm)-      micron to avoid scratches during transportation)
                         37.80Rm                 over frame structure of mild steel tubular trusses
                      e) Flashings/              and purlins using STSD (Self Tapping Self Drilling)
                         Corners.(Upto    200    screws having suitable washers. The Roof PUF
                         mm)- 135.70Rm           junction will be covered using 0.50 mm thick PPGI
                                                 ridge covering of same colour. The roof will have a
                                                 minimum projection of 300 mm from the eaves wall
                                                 and 300 mm at the both ends.

                                                 Make: Jindal Mectec/E Pack Polymer/Modern
                                                 Prefab Systems

04   Doors         01 No of size                 1. Main Door: Aluminum PUF Doors with double
                   1500x2100 mm                     leaf shutter of size 1500x2100mm will be
                                                    provided in each shelter. Doorframe will be
                                                    made up of suitable aluminum profile sections.
                                                    Main shutter will be of PUF panel fixed with
                                                    aluminium lipping all around .PUF panel shall
                                                    be made of (0.5 mm thick on both side) PPGI
                                                    steel ribbed sheet (pattern of ribs can be of
                                                    manufacturers design) cladding on both side
                                                    with a layer of rigid CFC free polyurethane foam
                                                    of density 40 kg+/-2kg /cum as insulation in
                                                    between. The thickness of PU foam layer in
                                                    door panel shall be 79 mm. Total thickness of

                                                                                              Page 9
PUF panel in door will thus be 80mm. The door
                                                         shall be fitted with following.
                                                               a. 03 x stainless steel tower bolts of 200
                                                                     mm long size and 01xstainless steel
                                                                     bow handle 150 mm from inside.
                                                               b. 01xstainless steel sliding bolt 300 m
                                                                     long and 01xbow handle 150mm size
                                                                     in the outside.
                                                      2. Store Room Door: Aluminium flush door with
                                                         shutter of size 900x2100mm will be provided.
                                                         Door frame will be made up of suitable
                                                         aluminium profile sections. Shutter will be of
                       01 No of size                     PUF panel fixed with aluminium lippping all
                       900x2100 mm                       around. PUF panel shall be made of (0.5mm
                                                         thick on both side) PPGI steel ribbed sheet
                                                         (pattern of ribs can be of manufacturers own
                                                         design)cladding on both side with a layer of
                                                         rigid CFC free polyurethane foam of density 40
                                                         kg+/-2kg/cum as insulation in between. The
                                                         thickness of PU foam layer shall be 79 mm.
                                                         Total thickness of PUF panel will thus be 80
                                                         mm. The door shall be fitted with following:
                                                               a. 02 x stainless steel tower bolts of 200
                                                                     mm long size and 01xstainless steel
                                                                     bow handle 150 mm from inside.
                                                               b. 01xstainless steel Aldrop 300 mm long
                                                                     and 01xbow handle 150mm size in the
                                                                     outside.
05   Windows       &   Window of size                 Windows.
     Ventilators       1200x1200 mm – 02 Nos           a. Two way sliding Window 1200x1200mm.
                                                             The window frame and window shutter will
                                                             be manufactured using suitable aluminium
                                                             profile sections. The window shutter will be
                                                             two sliding leaves both shall be provided
                                                             with 6 mm thick multi wall polycarbonate
                                                             sheet using stainless steel mesh of 1.5mm
                                                             aperture on outer side. All the shutters will
                                                             have aluminium protective grills of
                                                             appropriate design
                       Window of size600x1200mm-       b. Window 600x1200mm. The window frame
                       11 Nos                                and window shutter will be manufactured
                                                             using suitable aluminium profile sections.
                                                             The window shutter will be of single leaf be
                                                             provided with 6 mm thick multi wall
                                                             polycarbonate sheet using stainless steel
                                                             mesh of 1.5mm aperture on outer side. The
                                                             shutter will have aluminium protective grills
                                                             of appropriate design.
                                                      Ventilator
                       Ventilator of size 750x450mm    a. 750x450mm. The window frame and window
                       02 Nos                                shutter will be manufactured using suitable
                                                             aluminium profile sections. The window
                                                             shutter will be two sliding leaves both shall
                                                             be provided with 6 mm thick multi wall
                                                             polycarbonate sheet using stainless steel
                                                             mesh of 1.5mm aperture on outer side. All
                                                             the shutters will have aluminum protective
                                                             grills of appropriate design

                                                                                                Page 10
06   Finishing         ----------------    All steel members will be given two coats of Epoxy
                                           paint (two or more coats) at all locations prepared
                                           and applied as per manufacturer’s specifications
                                           including appropriate priming coat, preparation of
                                           surface, etc complete . Supply shall include all
                                           consumables for this purpose. All paint materials
                                           used shall be of reputed makes namely Make-
                                           Asian Paints /ICI/Nerolac/Dulux

07   Fasteners and     -----------------   Fasteners and fittings of Galvanised iron of sizes
     Fittings                              be used unless and otherwise specified

08   Electrification   ---------------     (Make: Havells/Crompton/Anchor)-as per CPWD
                                           Book of specifications.

                                           One 10W LED Light in each cabin and two No. in
                                           store cum reception. Total 10W LED = 35 (Inside
                                           and outside).
                                           6 Amp 3 Pin sockets = 4 No. in each cabin. Total =
                                           55 Nos. complete with gangue boxes of 8 Module
                                           with 1.00 mm² and 1.50 mm² wiring including
                                           flexible pipe/channels of appropriate size and
                                           off/on switches including cost and carriage of all
                                           material for completion of job.Main switch board: 4
                                           way gangue box with 16 Amp MCB = 2 Nos and
                                           32 Amp TPN = 01 No.
                                           Service wire 4.00 mm² = 30 m

                                                                                    Page 11
6 Terms and Conditions of Contract:
 6.1   Execution of work: The Contractor shall complete the work strictly and in
       accordance with the scope of work given in the DNIT (and as modified in the
       ‘Letter of Award’) to the total satisfaction of the Engineer-in-charge i.e. General
       Manager (Works) or any other Engineer appointed by CEO/ Addl. CEO, SASB).
       The Contractor must keep in daily contact with Engineer-in-charge to receive
       instructions regarding work. In the case of an item for which specification are not
       available in the said Specification, relevant BIS specifications applicable as on the
       date of Tender shall be followed or, alternatively, the specifications may be
       decided by the Engineer-In-Charge. Though it is not the intent to specify
       completely herein all aspects of design and constructional features of a prefab hut
       and details of work to be carried out, the work shall include all incidental and
       contingent work which, although not specifically mentioned in Scope of Work, are
       necessary for completion of work in a sound manner with good workmanship and
       should be acceptable to the Engineer-in-Charge, who will interpret the meaning of
       the specifications and drawings and shall have the right to reject or accept any
       work or material, which in his assessment is not complete to meet the
       requirements of the specifications and or applicable Standards and Codes
       mentioned elsewhere in the specifications.

 6.2 Role of Engineer-in-charge: The Engineer-in-charge shall carry out general
     supervision of the work. The work shall be subject to the approval of Engineer-in-
     charge from time to time for purposes of determination of the question whether
     the work is executed by the Contractor in accordance with the contract. He has
     authority to stop the work, whenever he considers such stoppage necessary to
     ensure the proper execution of the work. The Engineer-in-charge may issue
     instructions to the Contractor from time to time during the execution of work for
     the purpose of proper and adequate executions and maintenance of works and
     the Contractor shall carry out and be bound by the same. He shall also have
     authority to inspect and reject all works and materials, which do not conform to
     the specifications. No claim whatsoever on aforesaid account shall be
     entertained. In case of any clarification the Contractor may appeal to the General
     Manager (Works) whose decision shall be final and binding on the Contractor.
     The above inspection shall, however, not relieve the Contractor of his
     responsibilities in regard to defective materials or workmanship and the necessity
     for rectifying or replacing the same.

 6.3 Manner of Notice: Any notice required or permitted by the Contract shall be in
     English language and may be delivered personally or may be sent by fax/
     registered (pre-paid) mail/ email, addressed to the last known address of the
     Contractor/ Shrine Board.

                                                                                    Page 12
6.4 Contractor Superintendence, Supervision, Technical Staff & Employees:
    i. The Contractor shall be solely responsible for the manner and the method of
    executing the work and provide experienced and qualified supervisors and other
    manpower for continuous and efficient supervision of works and names, and
    names of such persons shall be intimated to the Engineer-in-charge during
    execution of the work and as long thereafter as may be necessary for proper
    fulfilling the obligations under the Contract. The Engineer-in-charge may direct
    the Contractor to remove or replace any workman whom he (Engineer-in-charge)
    considers incompetent or unsuitable. The Engineer-in-charge’s opinion as to the
    competence and suitability of any workmen engaged by the Contractor shall be
    final and binding on the Contractor.
      ii. The agency shall be solely responsible for Workmen's Compensation Act,
      1923 for payment of compensation to workmen and their dependants in case of
      injury and accident (including certain occupational disease) arising out of and in
      the course of employment and resulting in disablement or death.
6.5 Information to be supplied by Contractor after award of work: The Contractor
    after issue of Letter of Award of work, shall submit within five days of a Time
    schedule for fabrication, supply and installation at Lower Holy Cave/ Brarimarg for
    erection and handing over (completion) for approval of Engineer-in-charge. Any
    change suggested by Engineer-in-charge shall be incorporated and the work on
    the contract shall be executed according to the approved schedule as aforesaid.
    The schedule should be co-related with the date of commencement of Shri
    Amarnathji Yatra- 2021 (dates to be intimated later). The structures complete in
    all respects, but in knock-down condition should reach to the site of installation
    upto 20th May, 2021.
6.6 Commencement of work and completion of drawings: The Contractor shall
    be provided with one set of drawings containing details of construction layout,
    critical sectional details, piping routes along with dimensions with the Tender
    Document. These drawings shall be;
    a) All general arrangement drawings.
    b) Details along with drawings of various assembled equipment as may be
         needed generally by Shrine Board for purpose of dismantling/ re-erection/
         repair/ modification of structures.
6.7   Time Extension: If the Contractor shall desire an extension of the time limit for
      completion of the work on the grounds of his having been unavoidably hindered in
      its execution or on any other ground he shall apply in writing to the Engineer-in-
      Charge within one day of the date of the hindrance on account of which he
      desires such extensions and Engineer-in-Charge, if in his opinion (which shall be
      final) reasonable grounds as shown thereof, authorized such extension of time if
      any, as may, in his opinion be necessary or proper.

                                                                                Page 13
6.8     Inspection of Work:

 (i)     All work under or in course of execution or executed in pursuance of the
         contract shall at all times be open to the inspection and supervision of Engineer-
         in-charge or his subordinate in-charge of the work.

 (ii) The Contractor shall provide and pay for all necessary tools, instruments gadgets
       and testing equipments required for conducting various tests. Any defects in
       material and / or in workmanship detected during initial testing shall be rectified
       by the Contractor at his own cost. The testing shall be carried out in the
       presence of Engineer-In-Charge or his representative to his entire satisfaction.
       The Contractor will produce before the Engineer-in-charge a Test Certificate
       specifying that the material required for work conforms to ISI standards before it
       is incorporated in the work.

 (iii) Final inspection will be carried out at the installation site by the Engineer-in-
       Charge. Whenever preliminary inspection, if any, is carried out at Contractor’s
       works the same shall be subjected to final inspection after complete installation
       of structures at site (respective sites) and the decision of Engineer-in-charge
       shall be final.

 (iv)     The material rejected by Engineer-in-charge must be removed by Contractor
         within seven days of rejection, failing which the Board reserves the right to get
         the rejected material removed at the risk and cost of the Contractor.
6.9      Guarantee and Defect Liability Period: The work covered by this contract
         shall be guaranteed by the contractor against faulty material and workmanship
         for a period of 12 months from the date of issue of Completion Certificate
         by the Engineer-in-Charge. Any part found defective shall be replaced free of all
         costs by the Contractor. During the guarantee & defect liability, the Contractor
         shall provide, at no extra cost, necessary material and personnel to carry out the
         repairs and routine maintenance of the structures. If performance of assigned
         work during guarantee period is not found satisfactory, the guarantee period will
         be extended till satisfactory performance is established for further period of
         reasonable time decided by competent authority of SASB. The services of the
         contractor’s personnel, if requisitioned during the defect liability period, shall be
         made available free of any cost to SASB. If the defects noticed during the
         guarantee period are not removed within a reasonable time SASB shall have the
         right to restore/rectify the defects at the contractor’s risk & cost.
6.10 Performance Guarantee: (i) The work shall be executed according to the
     schedule approved by Engineer-in-charge. Delay in completion of job for a max
     period of 5 days shall attract a penalty @ 2% of Contract value. After 5 days
     delay, the General Manager (Works) reserves the right to get the work
     completed through alternate agency at the risk and cost of the Contractor. The
     CEO/ Addl. CEO, SASB, on a representation from the Contractor may reduce

                                                                                     Page 14
the amount of penalty and the decision of the competent authority shall be final
       and binding.

(ii) In the event of any loss being caused to the Shrine Board as a result of any
     lapse on the part of Contractor or personnel engaged by him, duly established
     after an enquiry conducted by the SASB, the said loss will be recovered from
     the Contractor upto twice the value of the loss. In such matters, the decision of
     CEO, SASB shall be final and binding on the Contractor.

(iii) In case, the Contractor fails to submit the Time Schedule as prescribed in
      Clause 6.5 above, he shall be liable to pay a sum equivalent to 1% of the value
      of the work subject or as may be fixed by the CEO, SASB and in this respect ,
      the decision of the CEO, SASB shall be final and binding on the Contractor .

(iv) If it shall appear to Engineer-in-charge, that any part of work has not been
    executed or executed with unsound, imperfect or unskilful workmanship or with
    materials of any inferior description or that any materials or articles provided by
    him for the execution of the work are unsound or of a quality inferior to the
    contracted for, or otherwise not in accordance with the contract specifications,
    the Contractor shall, on demand in writing from the Engineer-in-charge
    specifying the work materials, articles complained or not with-standing that the
    same have been inadvertently passed, certified and paid for, forthwith rectify or
    remove and reconstruct the work so specified in whole or in part as the case
    may require, or as the case, remove the materials or articles so specified and
    provide other and suitable materials or articles so specified at his own cost and
    in the event of his failing to do so within a period to be specified by the
    Engineer-in-charge, then the Contractor shall be liable to pay compensation at
    the rate of 1% on the amount of the estimate for every day not exceeding ten
    days and after completion of ten days the Engineer-in-Charge may rectify or
    remove, and re-execute the work or remove and replace with other materials or
    articles complained of, as the case may be at the risk and expenses in all
    respects of the Contractor. The Engineer-in-charge may reduce the rates at
    which payments are to be made if the quality of work, although acceptable, is
    not upto required standard, set forth in the DNIT (as modified by Letter of
    Award).

(iv)     Any deviation/ non-compliance with conditions prescribed in the contract shall
         invoke penalty as decided by CEO/ Addl. CEO, SASB.

                                                                               Page 15
6.11 On-Site Support during erection of structures: As a part of the support, the
      Contractor will provide qualified engineers and other works to execute the
      aforesaid works.
6.12 Conformity with Statutory Acts, Rules, Standards and Codes: The
     construction and installation shall be carried out in conformity with applicable
     Acts, Rules, Standards and Codes. Adherence of compliance shall be the sole
     responsibility of the Contractor to the above Acts, Rules, Standards and Codes
     applicable in Jammu and Kashmir to the said work.
6.13 Safety codes and regulations: The contractor shall at his own expenses
     arrange for the safety provisions as per statutory regulations wherever
     applicable.
6.14 Provision of utilities / tools etc: Power supply, water supply and other utilities,
     if required, at site of work during execution under this Contract shall be arranged
     by the Contractor at his own cost. The contractor shall be responsible for supply
     and transportation of water to work site in required quantities both for
     construction works and drinking purpose of his workers. The contractor shall be
     responsible for provision and transport of adequate and right type of tools/
     accessories, manpower etc in time for efficient execution of work and as may be
     suggested by Engineer-in-Charge in this regard.
6.15 Storage of materials and safe custody: The contractor shall be responsible
     for watch & ward and safe custody of his equipment and installation till they are
     formally taken over by SASB. Non-availability of lockable storage space due to
     any reasons shall not relieve the contractor of his contractual obligations in any
     manner.

6.16 Liability:

  i)    Except as otherwise expressly provided, neither the Board nor its employees,
        agents or nominees, shall have any liability or responsibility whatsoever to
        whomsoever (including the owner) for loss or damage to the equipment and or
        loss or damage to the property of Contractor .

  ii)   Neither the Board nor its employees, agents, nominees, assignees, shall have
        any liability or responsibility whatsoever for injury to, illness, or death of any
        employee of the Contractor irrespective of how such injury, illness or death is
        caused.

6.17 Patents and other Industrial Property Rights: The prices stated in the
     present Contract shall be deemed to include all amounts payable for the use of
     patents, copyrights, registered charges, trademarks and payments for any other
     industrial property rights. The seller shall indemnify the buyer against all claims
     from a third party at any time on account of the infringement of any or all the
     rights mentioned in the previous paragraphs, whether such claims arise in
     respect of manufacture or use. The seller shall be responsible for the

                                                                                  Page 16
completion of the supplies including spares, tools, technical literature and
       training aggregates irrespective of the fact of infringement of the supplies,
       irrespective of the fact of infringement of any or all the rights mentioned above.

6.18 Terms of payment: Contractor is to submit the bills in triplicate along with
     delivery challans to the Engineer-in-charge for works executed by him duly
     certified by the Engineer-in-charge. 85% Payment to the agency shall be made
     after supply and assembling/ erection at the respective site and the balance
     15% shall be made;

   a) 5% of the contract Value after completion of warranty period of one year.
   b) 5% of the contract Value after on-site support as per clause 6.11 is satisfactorily
       provided by the Contractor.
   c) 5% of the contract Value after successful maintenance period ending culmination
       of Yatra 2026.

6.19 The Contractor shall have no claim against the Shrine Board in respect of any
      work which may be withdrawn, but only for work actually completed under this
      contract. The SASB reserves the right to cancel the Agreement at any time
      upon full payment of work done and the value of the materials collected by the
      Contractor for permanent incorporation in the work under this Contract upto the
      date of cancellation of the Contract. The valuation of the work done and the
      materials collected shall be estimated by the Board’s Engineer in the presence
      of the Contractor. The Contractor shall have no claim to any further payment
      whatsoever. The valuation would be carried out ex-party if Contractor fails to
      turn up despite reasonable notice, which will be binding on the Contractor.
6.20 Contractor to be liable for all taxes / statutory levies: The rates specified in
      the tender shall be for finished work including installation at site and inclusive of
      all taxes as applicable.
6.21. Income Tax and GSTIN: i) Deduction on account of Income Tax, GST any
      other tax in vogue          shall be made at the rate prescribed by the
      relevant authority from time to time from the gross payments due to the
      contractor in accordance with the statutory provisions.

6.22 Termination and Consequences thereof:

  i)  The Contract shall be deemed to be automatically terminated on the expiry of
      duration of the Contract (or extension), if any, thereof.
  ii) In the event that the Contractor at any time during the term of the Contract,
      becomes insolvent or makes a voluntary assignment of its assets for the benefit
      of creditors or is adjudged bankrupt, then the Company shall, by a notice in
      writing have the right to terminate the Contract and all the Contractor’s rights
      and privileges hereunder, shall stand terminated forthwith.
  iii) If the SASB considers that, the performance of the Contractor is unsatisfactory,
        or not upto the expected standard, the SASB shall notify the Contractor in

                                                                                   Page 17
writing and specify in details the cause of the dissatisfaction. The Board shall
      have the option to terminate the Contract by giving seven (07) days notice in
      writing to the Contractor, if the Contractor fails to comply with the requisitions
      contained in the said written notice issued by the Board.
  iv) In case the Contractor’s rights and/ or obligations under the Contract and/ or the
      Contractor’s rights, title and interest to the equipment/ material, are transferred
      or assigned without the Board’s consent, the Board may at its absolute
      discretion, terminate the Contract.

  6.23   Consequences of Termination:

   (i) In all cases of termination herein set forth, the relative obligations of the parties
        to the Contract shall be limited to the period upto the date of termination.
        Notwithstanding the termination of the Contract, the parties shall continue to be
        bound by the provisions of the Contract that reasonably require some action or
        forbearance after such termination.
  (ii) If at any time during the term of the Contract, breakdown of Contractor’s
        equipment results in Contractor’s being unable to perform their obligation
        hereunder for a period of 7 successive days (not including Force Majeure
        delay), the Board at its opinion, may terminate the Contract in its entirety without
        any further right or obligation on the part of the Company, except for the
        payment of money then due. No notice shall be served by the Board under the
        condition stated above.
  (iii) Upon termination of the Contract, Contractor shall return to the Board all of the
        Board’s assets, which are in Contractor’s possession at the time.
  (iv) Notwithstanding any provisions herein to the contrary, the Contract may be
        terminated at any time by the Board on giving 7 (seven) days written notice to
        the Contractor and in the event of such termination, the Board shall not be liable
        to pay any cost or damage to the Contractor except for payment for service
        charges and other charges as per the Contract upto the date of termination.
  (v)      In the event of termination of Contract, the Board will issue Notice of
           Termination to the Contractor with date or event after which the Contract will
           be terminated. The Contract shall then stand terminated and the Contractor
           shall demobilize their personnel and materials.

6.24 Force Majeure: If at any time during the currency of the Contract, either party is
     subject to force majeure, like civil disturbance, riots, strikes, land disputes etc
     and acts of Gods, which may prevent either party to discharge the obligations as
     per the Contract, the affected party shall immediately notify the other party about
     happening of such an event. Neither party by reason of occurrence of such
     event be entitled to terminate the Contract in respect of performance of their
     obligations under the Contract. The performance of obligations under the
     Contract shall be resumed as soon as practically possible after the event has
     come to an end or ceased to exist.

                                                                                   Page 18
6.25 Annual Maintenance Contract:
        1) A 05 (five) year comprehensive Annual Maintenance contract for the items
        defined in the BOQ shall be entered into by the Bidder with SASB at the time of
        agreement of contract. The AMC shall be valid for a period of five years from the
        date of expiry of defect liability period of one year.
           1.1) The Contractor shall be responsible for the safe custody of all the
            dismantled material and cost & carriage of materials required for completion
            of job including machinery as may be required for the general maintenance of
            the structure during Yatra period.
           1.2) The work shall be carried out as per the specifications in the tender
            document. In case of any clarification about the specification to be
            followed/adopted for a particular item, the decision of the Engineer-in-charge
            shall be final and binding.
            1.3) The Contractor shall not assign the work further to sub-contractor. If the
            contractor does so, the contract shall be terminated without any notice and
            the job got done at the risk and cost of the contractor and the dues shall be
            debited to the security deposit of the contractor.
        2) The Bidder shall indicate a separate price for the Annual Maintenance
        Contract in his Bid on the prescribed format (BOQ) for AMC enclosed with
        Financial Bid.
       3) The AMC charges quoted in price schedule format shall be inclusive of all the
        charges of Transport, Lodging, Boarding, all insurances including third party
        insurance and all other incidental charges etc.
       4) The AMC charges shall be inclusive of all taxes including GST as applicable
        from time to time.
        5) The payment for the Annual Maintenance Contract charges shall be 100%
        after successful completion of job after the conclusion of Yatra every year.
        6) The contract shall be extendable for further 03 years subject to :-
            (i) Good performance & conduct by the Agency during maintenance period of
                05 years.
            (ii)The agency shall have to apply for such extension within two months of
                 culmination of Yatra 2026.
            (iii) Approval of Chief Executive Officer SASB.
            (iv)In case of approval, Earnest Money of tender shall be retained till
                 culmination of Yatra 2029.
   (v)      LoI shall be issued for drawl of agreement and after drawl of agreement,
            Letter of Award shall be issued.
6.26 The lowest Bidder shall be considered on the basis of sum total of
       (i) Supply and erection of Dormitory and (ii) Annual Maintenance Contract
     charges for a period of 5 years and not on the basis of Fabrication, Supply,
     Carriage and Installation of Dormitory only.

                                                                                   Page 19
6.27 Arbitration: Except where otherwise provided in the contract, all questions and
     disputes relating to the meaning of the specifications, designs, drawings and
     instructions here in before mentioned and as to the quality of workmanship or
     materials used on the work or as to any other question, claim, right, matter or
     thing whatsoever, in any arising out of or relating to the contract, designs,
     drawings, specifications, estimates, instructions, orders or these conditions or
     otherwise concerning the works, or the execution or failure to execute the same
     whether arising during the progress of the work or after the completion or
     abandonment thereof shall be resolved through joint discussions between CEO,
     SASB, or his representative and the Contractor. However, in the event of
     disputes not being resolved by joint discussions, the matter will be referred to a
     sole Arbitrator to be nominated by the Chairman, Shri Amarnathji Shrine Board,
     whose decision shall be final and binding on all the parties. The cost of
     Arbitration shall be borne by the respective parties in equal proportions. During
     the pendency of the arbitration proceedings and currency of Contract, neither
     party shall be entitled to suspend the work/ service to which the dispute relates
     or any other obligation under the Contract on account of arbitration and payment
     shall continue to be made as per terms of the Contract. The arbitration
     proceedings will be held at Srinagar only. It is also a term of this contract that
     no person other than a person appointed by the Chairman, SASB as aforesaid
     shall act as arbitrator. In all cases where the amount of the claim in dispute is
     Rs.50000/- (Rs. Fifty thousand only) or above, the arbitrator shall give reasons
     for the award. It is also a term of the contract that while invoking arbitration the
     party invoking arbitration shall specify the dispute or disputes to be referred to
     arbitration under this clause together with the amount or amounts claimed in
     respect of each such dispute. It is also a term of the contract that if a party does
     not make any demand for arbitration in respect of any claim(s) in writing within
     90 days of receiving the intimation from the Engineer-in-charge that the bill is
     ready for payment, the claim if any, shall be deemed to have been waived and
     absolutely barred and the owner shall be discharged and released of all
     liabilities under the contract in respect of these claims. The arbitration
     proceedings shall be governed by the provisions of the J&K Conciliation and
     Arbitration Act, 1997, as amended from time to time.
6.28 Jurisdiction: Notwithstanding any other courts having jurisdiction to decide the
     questions forming subject matter of a suit any and all actions and proceedings
     arising out of or relative to this contract (including any arbitration in terms
     thereof) shall lie only in the court of competent Civil jurisdiction in this behalf at
     Jammu and Kashmir, where this contract is to be signed on behalf of SASB and
     only the said court shall have jurisdiction to try any such actions and/or
     proceedings to the exclusion of all other courts.
                                                                 Sd/-
                                                              Addl. Chief Executive Officer,
                                                               Shri Amarnathji Shrine Board

                                                                                   Page 20
SCHEDULE – A (TECHNICAL BID)
     Part – A (Basic Details)

   S.                     Item                                         Details
   No.
   1     Name of Agency

   2     Legal Status of the Agency (whether a
         Company/ Society/ Firm)

   3     Address of the Agency (along with
         phone and email ID)

   4     Name, Address, Phone numbers Name:
         (Landline and Mobile) and email ID of
         the authorized person of the Agency
         with whom to deal
                                               Address:

                                                    Phone:

                                                    Email:

   5     PAN No. (please enclose an attested
         copy)
   6     GSTIN. (please enclose an attested
         copy)
   7     Details of Banker and Bank Account
         No.
   8     Availability of credit facility duly
         certified by the Bankers
          (not more than three months)
   9     Registration details:                      Registration No:
         Registration No. / other documents of
         the Agency                                 Date of Issue:
         (attach a certified copy of Registration
                                                    Date of Expiry:
         Certificate/ other documents; please
         see DNIT – ‘Documents Establishing         Authority with whom registered
         Bidder’s Eligibility’                      and their address:

                                                                                     Page 21
10   Name and address (along with phone S. Name                         Address
     numbers and Email) of Directors/ no.
     Owners/ Executive Council Members,
     as applicable (Add separate sheet, if
     necessary)
11   Amount and details of Tender Fee paid Rs. (in words):

                                               Receipt No./Cheque No:

                                               Date:

12   Bid Security Declaration                  Dated:

                                               Bid No.

                                               Name of Notary
13   Whether General Power of Attorney/
     Board of Directors Resolution/ Deed of
     Authority executed in favour of
     person(s) authorized to sign the
     Tender Document, and the Contract,
     and all correspondence Documents
     thereof attached (Please attach a
     certified  copy of the         relevant
     documents)
     (YES/ NO)?
14   Whether an Affidavit on Rs.100/-
     Stamp paper stating that every
     information furnished by the Tenderer
     is correct and to the best of his
     knowledge and that no criminal/
     income tax/ blacklisting case is
     pending against him attached
     (YES/ NO)?
     (Please attach the affidavit)

                                                                   Signature of Bidder
                                                                            (with seal)

                                                                                  Page 22
PART- B:   RELEVANT EXPERIENCE IN THE PAST SEVEN YEARS

           The Bidder is required to furnish the following information (please attach separate
           sheets where necessary):

    1.     (i)    Organizational Structure.

           (ii)   Range of services provided with specific details.

                                                                         _______________
                                                                         Signature of Bidder
                                                                                 (with seal)

    2.     Relevant experience in past seven years, (ending last day of month previous to the
           one in which applications are invited), as per format given in Annexure-A. The
           Bidder must furnish certified documents like Letter of Award, Work Order, Certificate
           of Completion etc. indicating experience and satisfactory execution of similar works
           for fulfilling the eligibility criteria and also furnish information in following format
           (please add rows as necessary for other sectors, if applicable):.

    3.     Description of specification along with Compliance Statement of specifications as
           per format given in Annexure-B.

PART- C:   DETAILS OF TURNOVER

           The Bidder must furnish certified copies of (a) Audited Balance Sheet of last three
           years, (b) Audited Income and Expenditure Statement of last three years, (c) Audit
           Report of last three years, and (d) Audited Profit and Loss Account of last three
           years and furnish the information in following format (please add rows as necessary).

            S.          Financial Year                            Turnover (Rs.)
            No.

            1.

            2.

            3.

                                                                            _______________
                                                                            Signature of Bidder
                                                                                       (with seal)

                                                                                          Page 23
PART- D:      DECLARATION CERTIFICATE

              I_____________________________________________,                     working
as___________________________ in this organization and authorized to issue this certificate,
certify that:

        (a) We have gone through the contents of the NIT dated          ______________ and
            the related Tender Documents and fulfil the prescribed eligibility criteria as per the
            Tender Document.
        (b) All relevant documents are enclosed with our Technical Bid.

        (c) The contents of our Technical Bid have been duly authenticated and are based on
            actual work carried out by our Agency, as per record.

        (a) We have understood that in case it is found that our agency does not fulfil any of the
            conditions, or relevant details/ supporting documents are not found to be enclosed,
            we may not be given any opportunity for any clarifications and our Technical Bid
            may be evaluated based on available documents in the Technical Bid.

                                                               ___________________________
                                                                Signature of the Bidder (with seal)

                                                                  Date:____________________

                                                                  Name:___________________

                                                                  Address:_________________

                                                                 Designation:

                                                                  ________________________

                                                                                            Page 24
ANNEXURE – A

                                     PERFORMANCE STATEMENT FORM
                                      (For a period of last seven years)
             Name of the Firm __________________________________________________

Order          Order   Description Price    Date of       Remarks      Have the               Contact
placed by      no.     and quality (Rs in   completion    indicating   fabricated items       person along
(full          and     of ordered lakh)     of delivery   reason       been                   with Tel. No.,
address of     date    works.               as per        for late     satisfactorily         Fax No. &
purchaser)                                  Contract/     delivery,    fabricated and         email address
                                            Actual        if any       supplied?              of the
                                                                       (Attach a              Purchaser/
                                                                       certificate from       Consignee
                                                                       the Purchaser/
                                                                       Consignee)
    1            2         3          4         5             6                7                    8

                                                                                           ______________
                                                                                          Signature of Bidder
                                                                                                (with seal)

                                                                                                     Page 25
ANNEXURE – B

      FORMAT OF COMPLIANCE STATEMENT OF SPECIFICATIONS

S. No. Name of             Specifications Compliance      Deviation, if any,   Whether the
       Specifications/     of quoted      whether         to be indicated in   compliance
       Part/ Accessories   Model/ Item    ‘YES’ or ‘NO’   unambiguous          deviation is clearly
       of Tender Enquiry                                  terms                mentioned in
                                                                               technical leaflet/
                                                                               literature
  1            2                 3              4                 5                       6

                                                                               _______________
                                                                               Signature of Bidder
                                                                                         (with seal)

                                                                                          Page 26
SCHEDULE –B(Format of Financial Bid) Part-I

        (Note: The bidders are requested to invariably quote rates(inclusive of all
        taxes and statutory levies) in both figures and words failing which the bid is
        liable to be rejected).

                                 Rate List/ Quantity Schedule
        Name of the Work :- Fabrication, Supply, Carriage and Installation of 02 No Dormitories
        (18.00mx5.30m each) at Lower Holy Cave before the commencement of Yatra-2021
     S.No: 01                                                 Adv. Amount:- Rs 40.48 Lakh

S. No      Item of work (Quantities worked out for 01 No.           Total      Unit   Rate to be      Amount
                                                                    Quantity          quoted by       (in Rs.)
           Dormitory).                                                                Bidder (in
                                                                                      Rs.
                                                                                      inclusive of
                                                                                      all taxes)
I.         STRUCTURAL STEEL                                         97.65      Sqm

             The min requirement of various structural members
             are as under mentioned

             (a)     Truss. Eight trusses , made of rectangular
                    tubular steel sections of size 80 mm x 40
                    mm, 4.0 mm conforming to IS 4923:1997
                    shall be provided. Base plate welded to the
                    truss on either side of min size 150 mm x150
                    mm. 10 mm thick with 04 pre drilled holes of
                    appropriate sizes to accommodate heavy
                    duty G.I bolts of appropriate dimensions with
                    nuts with GI and bitumen Washer with each
                    truss.
             (b) Purlins. Purlins made of square tubular steel
                    sections of size 49.5 mm x 49.5 mm, 3.6 mm
                    thick weighing 4.93 kg/m conforming to IS
                    4923:1997 alongwith 02 Nos. cleats of MS
                    cleat of min size 80 mmx120mm, 5 mm thick
                    continuously welded on both ends of the
                    Purlin duly drilled of 02 holes for bolts of
                    appropriate dimensions for fixing of purlin
                    with truss.
              Columns. Column shall be made of tubular section
              of size 100x100x4mm, both ends welded with M.S
              plate of size 200x200x12 mm at bottom and
              150x150x10mm at top. M.S plates shall have 04
              No of pre drilled holes for fixing with truss using

                                                                                                     Page 27
fasteners of appropriate size. Foundation bolts
   shall be min dia 20 mm and length 45 cm and
   foundation bolt plate of size 200x200x12mm with
   04 No. predrilled holes at appropriate place.

    WALLING AND GABLE
The wall panels shall be 80 mm thick made up of 79
mm thick polyurethane foam (PUF) as insulation
sandwiched between 0.5 mm thick grey/cream
colored Pre-Painted Galvanized Iron (PPGI) sheets
(ribbed type for all panels, joints angles, tracks,-
design of ribbing shall be manufacture’s own). PUF
used shall be CFC free and of density 40 kg+/-2
kg/cum and shall conform to IS 12436/19889
reaffirmed 2011. The wall PUF panel will be provided
with tongue and groove arrangement/shall be
interlocked using cam locks system. Gable ends will
also be covered with same panels as of wall. All
materials required for the manufacture of shelter will
be new and shall comply with relevant Bureau of
Indian Standards Specifications. The PUF insulation
material in the panel will have fire retarding and self
extinguishing properties as per international standard
B2 DIN 410part/BS-4735 Self Ext. The wall panel at
the top and bottom corners will be joined by U-
channel 80x50x3mm. Since all the flashings are of
PPGI no welding will be allowed. The PPGI angle and
flashings are to be bended or /& riveted to from the
desired shape and size.

   Make: Jindal Mectec/E Pack Polymer/Modern
   Prefab Systems

    ROOFING AND ITS ACCESSORIES
The roof shall be provided with 30/70mm thick PUF
panel (polyurethane foam conforming to IS
12436:1988 and PPGI         sheet conforming to IS
14246:2013 for yield strength and IS 277:2018 for
zinc coating , sheet shall have 5-7 micron epoxy
primer on both sides and polyester top coat of 15-18
micron .Also, sheet shall have guard film of 25 micron
to avoid scratches during transportation) over frame
structure of mild steel tubular trusses and purlins
using STSD (Self Tapping Self Drilling) screws having
suitable washers. The Roof PUF junction will be
covered using 0.50 mm thick PPGI ridge covering of

                                                          Page 28