IMEX in Frankfurt 2020 Technical Guidelines

Page created by Wayne Guzman
 
CONTINUE READING
IMEX in Frankfurt 2020 Technical Guidelines
IMEX in Frankfurt 2020
Technical Guidelines
Last Updated: January 2020
Contents

                                                     Page                                                             Page
1.       Preliminary remarks                             1        4.9.2    Restrictions applying to stand superstructures,
1.1      House Rules                                     2                 safety clearances and the heights of stand
1.2      Opening hours                                   3                              interiors                       31
1.2.1    Set-up and dismantling periods                  3        4.9.3    Live loads/design loads                      31
1.2.2    Opening hours during trade fairs/exhibitions             4.9.4    Escape routes / stairways                    31
                                                         3        4.9.5    Building materials                           31
2.       Traffic on the exhibition grounds, rescue routes,        4.9.6    Top floors                                   31
         safety equipment                                4        5.       Operational safety, technical safety provisions,
2.1      Traffic regulations                             4                 technical regulations and utilities          34
2.2      Rescue routes                                   4        5.1      General regulations                          34
2.2.1    Fire department maneuvering areas, fire hydrants         5.1.1    Damage                                       34
                                                         4        5.2      Employment of tools and other equipment 34
2.2.2    Emergency exits, emergency escape hatches,               5.3      Electrical installations                     34
         exhibition hall aisles                          4        5.3.1    Electrical outlets                           34
2.3      Safety equipment                                5        5.3.2    Electrical installations on stands           34
2.4      Stand numbering                                 5        5.3.3    Installation and operating regulations       34
2.5      Guard services                                  5        5.3.4    Safety precautions                           35
2.6      Evacuation in an emergency                      6        5.3.5    Emergency lighting                           35
3.       Technical data on, and equipment of, the                 5.4      Water and drain installations                35
         exhibition halls and outdoor exhibition areas            5.5      Compressed air/gas installation              35
                                                         7        5.5.1    Compressed air installations                 35
3.1      Hall data                                       7        5.5.2    Gas installations                            36
3.1.1    General lighting, types of electrical supplies, supply   5.6      Machinery, pressure vessels, exhaust systems
         voltages                                        7                                                              36
3.1.2    Compressed air, electrical and water supplies            5.6.1    Noise generated by machinery                 36
                                                         7        5.6.2    Product safety                               36
3.1.3    Communications facilities                       7        5.6.3    Pressure vessels                             37
3.1.4    Sprinkler systems                               7        5.6.4    Exhaust gases and vapours                    38
3.1.5    Heating, ventilation and air-conditioning       7        5.6.5    Exhaust systems                              38
3.1.6    Outages                                         7        5.7      Employment of compressed gases, liquefied gases
3.1.7    Stand air-conditioning                          7                 and combustible liquids                      38
3.2      Outdoor exhibition areas                        8        5.7.1    Compressed gas and liquefied gas systems 38
3.3      Designation of clear gate heights               8        5.7.2    Combustible Liquids                          39
4.       Stand construction regulations                  9        5.7.3    Combustible pastes and other fuels           39
4.1      Stand safety                                    9        5.8      Asbestos and other hazardous materials       40
4.2      Stand construction permits, project approval             5.9      Movie and TV screenings, slide shows and other
                                                         9                 presentations, stages                        40
4.2.1    Stand construction permits                      9        5.10     Radiation protection                         40
4.2.2    Vehicles and containers                         10       5.10.1   Radioactive materials                        40
4.2.3    Alterations to stand structures not in compliance        5.10.2    X-ray systems and sources of broadcast
         with regulations                                10                interference                                 40
4.2.4.   Limits of liability                             10       5.10.3   Laser systems                                41
4.2.5    Stand Construction Regulations                  10       5.10.4   LED                                          41
4.3      Construction heights                            16       5.11     High-frequency equipment, radio systems,
4.4      Fire protection and safety regulations          16                electromagnetic compatibility and harmonics
4.4.1    Fire protection regulations                     16                                                             41
4.4.2    Stand ceilings                                  24       5.12      Cranes, forklifts, and empty packings       42
4.4.3    Glass and acrylic glass                         24       5.13     Musical reproduction                         42
4.4.4    “Trapped rooms” / occupied rooms                24       5.14     Beverage dispensing systems                  43
4.5      Exits, escape routes, doors                     25       5.15     Food inspections                             43
4.5.1     Exits, escape routes                           25       5.16     Vehicle and driving demonstrations           43
4.5.2     Doors                                          25       6.       Environmental protection                     44
4.6      Platforms, ladders, stairs, landings            25       6.1      Waste                                        44
4.7      Stand Design                                    27       6.1.1     Waste disposal                              44
4.7.1    Stand appearance                                27       6.1.2    Hazardous waste                              44
4.7.2    Verification of rented areas                    27       6.1.3    Waste brought onto the exhibition grounds 45
4.7.3     Interventions in the structures and equipment           6.2      Water, waste water, soil protection          45
         of buildings                                    27       6.2.1    Oil/grease traps                             45
4.7.4    Exhibition hall floors                          27       6.2.2    Stand cleaning/cleaning agents               45
4.7.5    Suspension points/installation of trusses/               6.3      Environmental pollution                      45
         fasteners                                       28       6.3.1    Packaging materials                          45
4.7.6     Stand bounding walls                           29       6.3.2    Kitchen waste                                45
4.7.7    Advertising media/presentations                 29       6.3.3    Manufacturing wastes                         46
4.7.8    Barrier-free construction                       30       6.3.4     Stand components                            46
4.7.9     Foundations, pits                              30       7.       General information                          47
4.8      Outdoor exhibition areas                        30       7.1      Liability                                    47
4.9      Two-storey structures                           31
4.9.1     Requests for approval                          31
Technical Guidelines

1.      Preliminary remarks

Messe Frankfurt and Regent          conventional sense in the           the event will be sent to
Exhibitions Ltd. have issued        Technical Guidelines, it does       exhibitors if applicable.
guidelines for trade fairs and      not refer to a physicalstructure
other events in order that all      in the sense of the German          The trade fair companies
exhibitors/event organisers will    Federal Building Code (BauGB).      - Deutsche Messe AG Hannover
have optimum opportunities to       In legal terms, trade fair stand    - Leipziger Messe GmbH
present their exhibits and          constructions are considered to     - Messe Berlin GmbH
attract attendees and               be “facilities” in the venue.       - Messe Düsseldorf GmbH
interested parties to visit their   In the interest of all              - Messe Frankfurt Venue GmbH
stands.                             participants, Messe Frankfurt       - Messe München GmbH
These guidelines are binding        and/or Regent Exhibitions Ltd.      - Kölnmesse GmbH
upon all exhibitors and event       can prohibit the holding of an      - NürnbergMesse GmbH
organisers. They also               event and/or the opening of an      - Landesmesse Stuttgart GmbH
incorporate safety regulations      exhibition stand if defects         have compiled these Technical
that are intended to provide        previously found have not           Guidelines with a uniform
high degrees of safety in           been remedied by the start of       classification system.
relation to technical and stand     the exhibition.
equipment in the interest of        Messe Frankfurt and Regent          Building codes are issued by
protecting our exhibitors and       Exhibitions Ltd. retain the right   the governments of the
visitors. The building              to issue further safety             respective German states.
provisions, fire protection         regulations and stand               The respective event
regulations and other safety        construction standards at any       regulations may therefore
regulations involved have been      time. Messe Frankfurt and           differ from exhibition site to
coordinated with the                Regent Exhibitions Ltd. also        exhibition site due to differing
responsible agencies of the City    reserve the right to permit         local building codes and
of Frankfurt am Main.               exceptions to these regulations     differing construction
Messe Frankfurt and Regent          in individual cases.                conditions at the various
Exhibitions Ltd. reserve the        The documents required to           exhibition sites.
right to verify compliance with     order services will be sent in      Messe Frankfurt and/or Regent
these regulations.                  due time before the event.          Exhibitions Ltd. also reserve
Furthermore, the applicable         These Technical Guidelines          the right to modify these
legal regulations, as amended       must be forwarded to all of the     Technical Guidelines and other
from time to time, shall be         exhibitor’s contracting             regulations at any time.
observed at all times.              partners.                           The German version alone shall
Insofar as the term “stand          Further information on details      be binding.
construction” is used in its        of preparation and staging of

                                                   1
Technical Guidelines

1.1     House Rules

These Site Regulations apply        observed. Vehicles are subject     orders or the conducting of
throughout the premises of          to a 30 km/h speed limit. E-       surveys, if such activities take
Messe Frankfurt Venue GmbH          scooters, e-boards and other       place outside exhibition stands.
(hereinafter “Messe                 similar vehicles may not be        7. No commercial activities
Frankfurt”), including all          used in buildings or in out-door   are permitted on the exhibition
buildings, the Rebstock multi-      event areas during events.         grounds unless they are being
storey car park, Kap Europa         3. Messe Frankfurt shall be        conducted on behalf of Messe
convention centre and all           entitled to search the boots       Frankfurt or an organizer,
outdoor areas in the Rebstock       and cargo areas of vehicles and    exhibitor, lessee, service
area that are used by Messe         bags or personal items of          provider or other contracting
Frankfurt (hereinafter:             individuals at any time            party that has entered into an
“Exhibition Grounds”). Messe        regardless of whether there is     agreement with Messe
Frankfurt and the event             any suspicion of wrongdoing.       Frankfurt. Messe Frankfurt
organizer each have the right       Should anyone refuse               reserves the right to permit or
to enforce the Site Rules and       permission, Messe Frankfurt        prohibit the activities of third
Regulations. Any additional         reserves the right to expel        parties acting on behalf of
agreements reached with             them from the exhibition           contracting parties and to
exhibitors, service partners etc.   grounds.                           specify the type, scope and
remain unaffected.                  4. Messe Frankfurt has the         conditions of their activities.
                                    right to issue restrictions on     8. Over-the-counter sales, cash
1. Entrance to the exhibition       the admission of visitors and to   sales, or the acceptance of
grounds on foot or in vehicles      prohibit the transport of          exhibited goods during trade
is only permitted with proper       animals or items onto the          fairs and exhibitions is
and valid authorization             exhibition grounds; it may         prohibited. If goods are given
(employee IDs, service partner      either issue general provisions    away free as samples, the
IDs, event-specific admission       or make such restrictions          exhibitor must provide the
tickets, set-up and dismantling     dependent on the satisfaction      third party with a
passes) at predefined times         of specific requirements in        corresponding declaration of
and in the predefined areas of      individual cases. Children and     transfer (receipt). Third parties
the exhibition buildings and        young people under the age of      must demand a receipt from
grounds. Messe Frankfurt            14 may only enter the              the exhibitor and must produce
reserves the right to conduct       exhibition grounds in the          this on request. Should any
spot checks of individuals to       company of an official guardian    such third party be found
ensure that they are                of suitable chaperone.             without a receipt, Messe
authorized to be on the             5. Messe Frankfurt accepts no      Frankfurt reserves the right to
exhibition grounds, regardless      liability whatsoever for any       impound the goods without
of whether they are suspected       personal injury, property          compensation and expel the
of wrongdoing.                      damage or financial loss that      third party from the exhibition
                                    might occur at the exhibition      grounds.
2. The provision of the German      grounds.                           9. Devices that can be used to
Road Traffic Regulations (StVO)     6. Unless Messe Frankfurt has      produce photos or film are
are applicable for everyone o       given express permission, it       prohibited throughout the
the exhibition grounds. All         does not allow advertising of      exhibition grounds. Filming,
signs regulating vehicular and      any kind, neither does it permit   taking pictures and making
pedestrian traffic on the           the offer of goods or services     sketches of exhibited goods on
exhibition grounds must be          of any kind, the acceptance of     the exhibition grounds in the

                                                   2
Technical Guidelines

exhibition halls is only            video surveillance for security     confiscate their access
permissible in exceptional          reasons.                            documents without
cases with the written consent      11. Instructions given by           compensation, and to have any
of Messe Frankfurt. If there is     Messe Frankfurt security staff      vehicles removed from the
reasonable suspicion, Messe         and stewards must be followed       premises at the expense and
Frankfurt is entitled to            at all times.                       risk of the owner or operator.
confiscate any sketches,            12. In the event that the Site      13. A limited road and walkway
photographs or other film           Rules and Regulations are           clearance service is provided
materials that have been made       violated, access documentation      during the winter months. This
and have these destroyed            is misused or forged, or there is   applies for both restricted and
without providing                   other disruptive behavior,          the publicly accessible areas of
compensation. This also applies     Messe Frankfurt reserves the        the Messe Frankfurt exhibition
if other film or photographic       right to expel those responsible    grounds.
material will be destroyed as a     from the exhibition buildings
result.                             and grounds and to issue a          As at: October 2019
10. It should be noted that the     temporary or permanent ban
exhibition grounds are under        on their return, as well as to

____________________________________________________________________________________________
1.2 Opening hours

1.2.1 Set-up and dismantling        into stands, shall have been        termination of dismantling
periods                             concluded and the exhibition        periods.
In general, stand building and      hall vacated no later than the      In the interest of general
deliveries of exhibited goods       second calendar day following       safety, all exhibition halls and
may commence four (4)               the close of the event involved.    the exhibition grounds shall
calendar days prior to the          The exhibitor and any stand         remain closed outside official
opening of the event involved.      construction companies they         set-up and dismantling periods
During the general set-up and       work with should report to the      and event opening hours.
dismantling periods, work in        service office responsible for
the exhibition halls and on the     the hall both at the start of       1.2.2 Opening hours during
outdoor exhibition areas may        stand set-up and at the end of      trade fairs/exhibitions
proceed around the clock, that      dismantling. Stand areas shall      Exhibition halls shall be opened
is, 24 hours per day (normally      be swept and returned in a          one hour prior to the official
no work may be performed            clean condition.                    opening of the trade fair and
after 3 p.m. on the final days of   In special cases, Regent            shall be closed one hour after it
set-up periods, however),           Exhibitions Ltd. may grant          closes, on every day the event
unless other hours and a            extensions of set-up and/or         involved is officially open.
schedule of working hours           dismantling periods.                Exhibitors who, in special
have been announced for a           Exhibition halls are neither        cases, have valid grounds for
particular event.                   heated nor air-conditioned          working on their stands
In general, dismantling of stand    prior to the official               outside said opening hours
equipment and furnishings,          commencement of set-up              shall require special written
including exhibitors’ own stand     periods or following the official   permits issued by Regent
structures and structures built                                         Exhibitions Ltd.

                                                    3
Technical Guidelines

         4
Technical Guidelines

____________________________________________________________________________________________
2.     Traffic on the exhibition grounds, rescue routes, safety equipment

2.1 Traffic regulations, parking permits

All rules directing and
regulating traffic, such as those      Engines must be turned off         Driving any type of vehicle on
described in the Traffic               during loading/unloading.          the exhibition grounds requires
Regulations, and all                   Before entering/exiting            a permit from Messe Frankfurt,
instructions given by the              exhibition halls, drivers must     is at drivers’ own risk, and is
personnel deployed by Messe            come to a full stop and ensure     prohibited at all times during
Frankfurt for this purpose, shall      that gates offer sufficient        events. There is a limited
be observed at all times.              overhead clearance. Parking        number of car parking spaces
The exhibition grounds are the         vehicles in the exhibition halls   available for exhibitors on the
private property of Messe              is prohibited.                     exhibition grounds. In
Frankfurt. The provisions of the       Caravans/campers may not be        accordance with the number of
StVO (German road traffic              used on the exhibition             spaces available, parking
regulations) apply throughout          grounds.                           permits can only be ordered
the exhibition grounds and             Illegally parked vehicles,         for the entire duration of the
on/in Messe Frankfurt’s                trailers, containers, and goods    event using the corresponding
parking facilities. The speed          of any kind may be removed by      form (please also see the
limit on the exhibition grounds        authorized towing companies        Transport Guidelines).
is 30 km/h.                            working under contract to
If called for by traffic               Messe Frankfurt at their
conditions, vehicles must not          owners’ or operators’ expense
exceed walking speed.                  and risk.

2.2 Rescue routes

2.2.1 Fire department                  2.2.2 Emergency exits,             Escape and rescue routes in
manoeuvrings areas, fire               emergency escape hatches,          exhibition halls shall not be
hydrants                               exhibition hall aisles             constricted by objects
The necessary fire-department          Escape and rescue routes shall     deposited therein or extending
entry routes and manoeuvring           be kept clear at all times. It     into them at any time. In the
areas designated by “no-               must be possible to easily open    event that these rules are not
parking” signs must be kept            the doors along escape and         complied with, Messe
clear at all times. Vehicles or        rescue routes from the inside      Frankfurt shall be entitled to
objects parked/deposited in            to their fully open position.      remedy the situation at the
rescue routes or on safety             Escape and rescue routes, exit     expense and risk of the
areas shall be removed at their        doors, emergency exits and         responsible party.
owners’ expense and risk. Fire         their identifying signs or         Materials required for
hydrants in the exhibition halls       markings must not be               constructing stands or exhibits
and on outdoor exhibition              obstructed, obscured, have         delivered for immediate
areas shall not be obstructed          anything built over them, be       installation at the stand area
or rendered unrecognisable or          blocked, have anything hung        may be deposited in the escape
inaccessible.                          on them or otherwise be            and rescue routes for a short
                                       rendered unrecognisable.           period of time during the setup

                                                      5
Technical Guidelines

and dismantling phases as long     aisle is used to deposit items.   their entire width must be kept
as the aisle widths required for   Regardless of the width of the    clear at all times. Hall aisles
safety reasons are maintained      hall aisle and the items          may not be used for assembly
and logistical concerns are        deposited there, it is            or to set up machines (e.g.
sufficiently taken into            mandatory to maintain an          woodworking equipment,
consideration.                     unblocked passageway of no        workbenches etc.).
This will be considered to be      less than 1.2 m in width. Areas   Regent Exhibitions Ltd. may
fulfilled if a strip of no more    in front of emergency exits and   (also) request the immediate
than 0.9 m in width between        areas where hall aisles           clearing of the hall aisles for
the stand border and the hall      intersect are the exception:      logistical reasons.

2.3. Safety equipment

Sprinkler systems, fire alarms,    and other items of safety         remain visible and accessible at
fire extinguishers, smoke          equipment, their signs or         all times, and shall not be
detectors, mechanisms for          markings, and green               obstructed or enclosed.
closing exhibition hall doors      emergency exit signs shall

2.4. Stand numbering

All shell scheme stands will be    number. Stand numbers can         can arrange this on the
marked with stand numbers by       be ordered via Messe Frankfurt    exhibitor’s behalf and charge
Regent Exhibitions Ltd. All        Serviceshop. If the exhibitor     him afterwards.
space only stands need to          has not provided stand
provide their own stand            numbering the show organiser

2.5. Guard services

Messe Frankfurt, Messe             Exhibitors are expressly          Messe Frankfurt or its
Frankfurt’s external service       informed that exhibited           contractual service partner(s).
partners and Regent                materials and other objects       Exhibitors may order stand
Exhibitions Ltd. monitor the       brought by the exhibitors are     guards no later than six weeks
exhibition halls and outside       subject to greater risk during    before the start of the event
areas during the set-up and        set-up and dismantling periods.   with the corresponding order
dismantling phases, as well as     Valuable and easily moveable      form (please go to Messe
while events are underway.         objects should always be          Frankfurt Serviceshop online).
However, Messe Frankfurt and       locked away at night.             Ordering stand guards involves
Regent Exhibitions Ltd. accept     Security for the stand and the    submitting a fully completed,
no responsibility for property     objects brought by the            preprinted order form for the
and objects brought or             exhibitor must be arranged by     event involved.
delivered by exhibitors and        the exhibitor where necessary.    Oral or telephone orders for
third parties acting under         As a general rule, stand guards   stand guarding must be
Messe Frankfurt’s or Regent        may only be posted between        confirmed in writing by
Exhibitions Ltd’s instructions.    6:00 p.m. and 8:00 a.m. by        applicants. All orders for stand

                                                  6
Technical Guidelines

guarding must be signed by         brought onto the exhibition
applicants. Messe Frankfurt        grounds, even for guarding
service personnel is not           purposes.
authorised to assume
responsibility for monitoring
for third-party property.

Dogs shall be kept on a leash at
all times. Weapons may not be

2.6. Evacuation in an emergency

Messe Frankfurt may order to
evacuate a building and/or
rooms inside for safety
reasons.

                                                 7
Technical Guidelines

____________________________________________________________________________________________
3.     Technical data on, and equipment of, the exhibition halls and outdoor exhibition areas

3.1 Hall data

Since the technical data on the      3.1.3 Communications                can be made using the access
various exhibition halls differ      facilities                          point configuration menu. Any
from hall to hall, they have         Stands located in exhibition        transmitters other than WiFi
been listed in a separate            halls are supplied with             transmitters are prohibited, as
document (cf. the document           telephone, fax, data and            they can cause massive
entitled “Technical Data on the      antenna lines via existing          disruption to signals. In the
Exhibition Halls of Messe            installation channels and           event that exhibits require
Frankfurt”).                         connection points in hall floors.   different transmitters, please
                                     On exhibition hall floors having    contact us in advance.
3.1.1 General lighting, types        supporting columns,                 Naturally the aforementioned
of electrical supplies, supply       connection points are also          rules and regulations are also
voltages                             available at terminal boxes         applicable for WiFi transmitters
The general lighting in the          mounted on these supporting         in exhibits. The operation of
exhibition halls differs from hall   columns.                            WiFi networks that cause
to hall, and ranges from around      Guidelines for the operation of     interference or disruption is
300 lux to around 400 lux,           exhibitors’ own WiFi networks       prohibited. Messe Frankfurt
measured one meter above             at Messe Frankfurt: Exhibitors’     reserves the right to shut down
floor level. The electrical          own WiFi transmitters may           these networks. Forms for
supplies and supply voltages         only transmit in the 2.4 GHz        registering your own access
avail- able on the exhibition        band in accordance with             point are available at
grounds are as follows:              currently applicable standards      www.messefrankfurt.com.
Network type: TN-C-S                 (802.11 b/g/n); transmission in     Exhibitors’ own WiFi
Supply voltage: 230 V / 400 V        the 5 GHz band is prohibited!       transmitters must be
Tolerances as per DIN EN             The 5 GHz band is reserved          registered in good time before
50160                                exclusively for Messe Frankfurt     a trade fair in order to ensure
                                     in order to allow for the           that these rules are complied
                                     provision of exhibitor-specific     with by all exhibitors.
3.1.2 Compressed air,                solutions. As a result, WiFi
electrical and water supplies        transmitters may only transmit
The compressed air, electrical       on channels 1, 6 or 11, and         3.1.4 Sprinkler systems
and water supplies on stands         cannot be configured for            Exhibition halls are equipped
located in exhibition halls are      automatic channel search.           with sprinkler systems. Exhibits
routed through existing              Channel bonding is not              and decorations must be
installation channels to             permitted, and the maximum          situated at least 1.0 m from
connection points in hall floors.    channel bandwidth is 20 MHz.        sprinkler heads. Distances
On exhibition hall floors having     The maximum transmission            between lamps/ spotlights and
supporting columns, electrical       power of the exhibitor’s            sprinkler heads should be
sup- plies are also available at     transmitter may not exceed -80      chosen so as to preclude false
terminal boxes mounted on            dBm at the edge of the stand.       triggerings of fire extinguishing
these supporting columns.            The SSID, i.e. your access point    devices through the heat
                                     ID, must begin with your stand      generated by the lighting.
                                     number (e.g. H4.0 B42). All of
                                     the aforementioned settings

                                                    8
Technical Guidelines

3.1.5 Heating, ventilation               notified immediately in the       3.1.7 Stand air-conditioning
and air-conditioning                     event of any outages of           It is possible to individually air-
All halls are equipped with              utilities, such as electricity,   condition stand areas. Messe
heating, ventilation and air-            water, compressed air, heating,   Frankfurt’s Exhibitor Service
conditioning systems. These              ventilation or                    would be happy to provide you
systems will be operational as           telecommunications systems,       with an individual offer. It is
required throughout events.              etc. Messe Frankfurt and          not permitted to use drinking
                                         Regent Exhibitions Ltd. assume    water to flow-cool stands.
3.1.6 Outages                            no liability for any losses or
Messe Frankfurt and or Regent            damage due to such outages.
Exhibitions Ltd. should be

3.2. Outdoor exhibition areas

Outdoor exhibition areas are
paved with asphalt or stones.
The grounds have general road
and walkway lighting systems
that will be activated at the
onset of darkness during event
opening hours. Necessary
utilities connections are spaced
at irregular intervals.

3.3. Designation of clear gate heights

Gates having clear heights less
than 4.00 m are designated by
signs.

                                                       9
Technical Guidelines

____________________________________________________________________________________________
4. Stand construction regulations

4.1 Stand safety                      high decorative elements)         Messe Frankfurt on request
Exhibition stands – including         which might tip over must be      (see Item 4.2.1). Deviations are
furnishings, exhibits and             designed to withstand the         possible in justified exceptional
advertising media – must be           following equivalent              cases and require detailed
structurally stable to ensure         distributed lateral loads qh:     documentation. Bracing stands
that there is no threat to public     qh1 = 0.125 kN/m² up to 4 m in    against neighbouring stands or
safety and order, and in              height measured from the top      existing building structures is
particular that there is no           of the floor                      prohibited.
danger to life or health. The         qh2 = 0.063 kN/m² for all areas   In justified cases, Messe
exhibitor is responsible for the      more than 4 m high measured       Frankfurt reserves the right to
structural safety of their            from the top of the floor         engage a structural engineer to
stands, and may be required to        The reference area is the         conduct a chargeable
submit proof of same. Standing        respective surface area.          verification of stand stability on
constructional elements or            Verifiable/verified proof of      site.
special constructions (e.g. free-     compliance is to be compiled in
standing walls, high exhibits,        advance and presented to

4.2 Stand construction permits, project permission
                                                                        veranstaltungstechnik@messefran
Permits are not required for          Special constructions include:    kfurt.com
the following:                        – Stand structures and            After the stand plans have
For single-storey stands                exhibits that are more than     been inspected, one copy will
- that are not considered to            4 metres in height              be stamped as having received
     be special constructions         – Closed ceilings                 permission and returned to the
- whose stand area is less            – Platforms and stages higher     exhibitor / stand constructor if
     than 100m²                         than 0.20 m                     accepted. Stand construction
- whose height does not               – Glass constructions             may not commence until the
     exceed 4.00m                     – Moving components               plans have stamped as having
it is not necessary to submit         – Floor/ceiling connections       received permission. In order
planning documents.                                                     to receive permission for the
                                      4.2.1 Inspection and              following:
Permits are required for the          permission for structures         - Special constructions
following:                            requiring a permit                - Two-storey Structures
Exhibition stands larger than         Dimensioned stand plans           - Stands in outdoor areas
100m² in area, stands located         drawn to a suitable scale (e.g.   - Temporary structures
in outdoor areas, temporary           1:100), labelled in English or    - Stages and platforms
structures, mobile stands, two-       German, accompanied by floor      The following documentation
storey stands, special                plans (as well as sectioned       must be submitted in digital
structures and special                views and perspective views if    form (PDF) in German or
constructions require consent         appropriate), shall be            English by no later than six
and inspection, and are subject       submitted digital form (PDF)      weeks before the start of set-
to additional cost. Any cost          for approval by no later than     up:
incurred will be invoiced to the      six weeks before the start of     a) Structural calculations
exhibitor / stand constructor.        setup to:                         complying with German
                                                                        building standards which are
                                                     10
Technical Guidelines

checkable or have been                  The firm of engineering            have been concluded by the
checked by a second                     consultants will contact the       appointed time, Regent
independent structural                  stand construction manager at      Exhibitions Ltd. shall be
engineer                                a specified time / after           entitled to make the required
b) A building description               consultation to provide            alterations at exhibitors’
specifying the materials used           assistance and examine             expense.
(including certificates in              structural characteristics, and
German or English where                 to inspect the structure for a     4.2.4. Limits of liability
applicable)                             fee. Due to the additional work    Regent Exhibitions Ltd. shall
c) Stand construction drawings          entailed, the absence of           not be held liable for theft or
to a suitable scale, e.g. 1:100         structural calculations results    deterioration of, or damage to,
(floor plans, perspective views,        in additional costs for the        drawings, models, or other
sectioned views) as well as a           exhibitor / stand constructor.     items of documentation
ceiling plan with dimensions of                                            submitted, regardless of any
the closed ceiling(s)                   4.2.2 Vehicles and containers      legal grounds that might apply.
d) Escape route plan including          Vehicles and containers            In the event that the exhibitor
lengths and widths of                   scheduled to be employed as        or his subcontractor fails to
emergency escape route(s).              exhibition stands in exhibition    comply with the stand
e) Submission of a type                 halls require approval.            construction regulations, the
certification / certification book                                         exhibitor shall assume full
renders item a) superfluous.            4.2.3 Alterations to stand         liability for any damage arising
In the event that structural            structures not in compliance       as a consequence of his
calculations examined by a              with regulations                   violation of these stand
second, independent structural          Stand structures that have not     construction regulations.
engineer are not submitted,             been approved or fail to           Furthermore, the exhibitor
Messe Frankfurt will                    comply with these Technical        shall indemnify Regent
commission a firm of                    Guidelines or the state of the     Exhibitions Ltd. from any third-
engineering consultants to              art shall be altered or removed    party claims asserted with
check the plans and separately          from the premises.                 respect to the violation of the
invoice the exhibitor / stand           In the event that said             aforementioned stand
constructor for their services.         alterations or removal shall not   construction regulations.

4.2.5. Stand Construction Regulations

Please DO NOT                           • cut any metals or wood in the      on the carpets of the
• damage any pillars in the Hall          Hall as these produce              neighbouring stands.
  – any damage, i.e. painted or           flammable sparks.                • use gas stoves as open flames
  chipped pillars, will be              • cover any open facing stand        or gas-cartridge are not
  charged to you after the                sides (sides facing the            allowed in the exhibition hall.
  show.                                   perimeter) by more than          • welding, oxyacentylene
• damage Shell Scheme Walls               30%.                               cutting, soldering/brazing and
  with sticker/tape traces.             • exceed the stand height of         grinding/cutting without any
  Damaged walls will be                   8m.                                permission of Messe
  charged to you at €50 per             • block the aisles with your         Frankfurt.
  wall after the show.                    stand building material or
                                          deposit your building material   Please note that you MUST

                                                      11
Technical Guidelines

• go outdoors to cut any metal      Please see section 4.2.5.24 for     or more people must be
  or wood.                          more detailed information on        located towards the centre of
• finish the back of any back       closed ceilings.                    the stand and clearly shown on
  facing walls that are                                                 stand drawings. If any
  overlooking other stands in       4.2.5.3.1. Installation of a Fire   presentation/demonstration
  white and on an even surface.     Alarm System                        causes obstruction within the
• use sprinkler-compatible          Approval for construction of        gangway and/or nuisance to
  fabrics with a mesh width of      completely or partially closed      any other Exhibitor, the
  2mm x 4mm or 3mm x 3mm            ceilings may be given in            Organisers reserve the right to
  to cover ceilings otherwise       accordance with the Messe           cancel the presentation/
  you will have to install a        Frankfurt restrictions. Stands      demonstration or restrict the
  smoke detector and/or other       with more that 30sqm ceiling        frequency. Amplification is
  additional equipment              space will need to install a fire   generally not necessary for
• fix a stand number to your        alarm system. For details of        presentations. The Organisers
  stand design.                     regulations required please see     reserve the right to stop
• keep all main access aisles       the tables under section 4.4 in     without warning any
  clear at all times (you will      the IMEX Technical Guidelines.      presentation or performance
  receive a floor plan with the     The exhibitor can ask Messe         judged by them to be at
  access aisles marked closer to    Frankfurt for detailed              excessive sound levels.
  the exhibition).                  regulations with regard to the
For more details regarding          construction of partially closed    4.2.5.7. Lighting
build-up and breakdown please       ceilings. Please contact Anette     Where illuminated fascia
contact the IMEX Organisers.        Berz: Tel: +49 69 75 75 57 86,      boards are used on stands, the
                                    Fax: +49 69 75 75 63 87,            lighting of them must be of
4.2.5.1 Enclosed Areas              anette.berz@messefrankfurt.c        sufficient power to light the
The inclusion of large enclosed     om.                                 fascia board only, and must not
areas within a stand can only                                           cause any spill of light onto
be permitted with the               4.2.5.4. Removal/Alteration         neighbouring stands. No
Organisers’ prior written           The organisers may, at the          flashing lights will be
permission.                         expense of the Exhibitor,           permitted. The Organisers
                                    remove or alter anything in or      reserve the right to disconnect
4.2.5.2. Suspensions                forming part of any stand, if, in   the electrical supply to any
Suspension points in Hall 8 are     their opinion, it is desirable to   illuminated fascia which, in our
not readily available and ceiling   do so in the interests of the       opinion, is causing a nuisance
trussing may have to be fitted      Exhibition.                         to any other Exhibitor.
to your suspension point. This
may have high cost                  4.2.5.5. Stand Perimeters           4.2.5.8. Exhibition Premises
implications. For more              Each stand wall facing an aisle     Nothing may be attached to
information on suspensions          must remain at least 70% open.      the floor or to any other part of
and alternatives to these           Runs of walls beyond 2 meters       the Exhibition premises
please view the suspensions         in length are prohibited along      without the written consent of
order form in the Messe             open perimeters of stands.          the Landlords. It is essential to
Frankfurt Serviceshop.                                                  use a recognised adhesive tape
                                    4.2.5.6.                            when fixing any carpet directly
4.2.5.3. Construction of            Presentation/Demonstration          to the hall floors, all carpet
ceilings on Exhibition Stands       Any                                 tape must be removed at the
                                    presentation/demonstration          end of the Exhibition. Any
                                    likely to interest groups of 10     charges incurred by the

                                                   12
Technical Guidelines

Organisers as a result of failure   cleaning to be carried out at no     than 8 weeks prior to the
to remove carpet/carpet tape        charge to the exhibitor. This        show. For more information
will be passed on to the            does not apply to the second         please refer to the Registration
Exhibitor.                          storey stands where a charge         section under Stand
                                    will be made. The basic stand        Constructor Details in the
4.2.5.9. Mobile Units               cleaning will include vacuuming      Messe Frankfurt Serviceshop.
Mobile Exhibition units,            and emptying of waste bins
caravans or similar vehicles are    and will be carried out after the
not permitted without our           show closes. Additional rubbish      4.2.5.15. Stand Design
prior written consent.              should be placed in sealed           Stand Coordinators are
                                    rubbish bags and should be           responsible for their own stand
4.2.5.10. Platforms                 placed in the aisle after 17:30      design and construction. A
Static certifications for           for overnight collection. Glass      drawing or plan of the
platforms over 20cm shall be        is to be placed in separate bags     proposed stand installation,
submitted; the inspection and       which should be left open for        showing the ground plan with
approval of these special           recycling purposes. Please           highlighted ceiling areas,
constructions may generate          notify Messe Frankfurt Venue         elevation and electrical must
additional costs for the            GmbH & Co. KG in case of toxic       be submitted in duplicate to
exhibitor/constructor.              waste. As is usual, the cleaning     the Organisers for examination
                                    of exhibits will remain your         and approval 6 weeks prior to
4.2.5.11. Details of Contractors    responsibility as will any special   the show. Please e-mail your
In order to achieve a smooth        services that may be required        stand plan to
preparation to the Exhibition,      such as the removal of bulk          Organising@imexexhibitions.co
all Exhibitors should provide us    rubbish. Please note: Exhibitors     m.
with details of their selected      should use, whenever possible,       All interior stand fittings must
contractors. Build-up and           recyclable materials for stand       be contained within the stand
Breakdown passes must be            structure and decoration.            area and should not extend
ordered in advance. Please                                               into the aisle area. All stand
refer to the Registration           4.2.5.13. Space Only Stands          plans will be subject to
section under Stand                 Exhibitors are responsible for       approval of both the
Constructor Details for more        their own stand design and           Organisers and the Landlord
details and how to order            construction.                        and must fully comply with the
passes.                             No stand fitting, walling or         Landlord’s regulations. The
                                    floor covering is provided by        Organisers reserve the right to
4.2.5.12. Stand Cleaning            the Organiser on SPACE ONLY          prevent work being carried out
During build-up and                 STANDS.                              by or on behalf of any stand
breakdown every exhibitor is                                             Coordinator who has not
responsible for removal of all      Stand Construction                   submitted stand design
waste and refuse from their         Company Details and Stand            drawings in accordance with
stands. Stand building              Design Approval                      this regulation.
contractors are responsible for
leaving individual stands in a      4.2.5.14. Stand Construction         4.2.5.16. Stand Height
clean and tidy condition for        Company Details                      The overall height of stand
exhibitors. It is your              Stand Coordinators are               fitting for single storey stands
responsibility to maintain your     responsible for registering their    should not exceed 8.00m
stand in a clean condition at all   Stand Construction company           above floor level.
times. We have made                 via the IMEX website. Please
arrangements for basic stand        register your company no later       4.2.5.17. Stand Number

                                                   13
Technical Guidelines

All stands must be clearly           Storey structures may be built     routes / stairways) all in the
marked with their allocated          to a maximum height of 8.0m        IMEX Technical Guidelines.
stand number. Stand                  (including any name sign or        APPROVAL CANNOT BE GIVEN
numbering will be provided for       trade mark). Any other             TO PLANS VIA FACSIMILE. The
shell scheme stands only.            construction element must          Organisers reserve the right to
Space only stands must ensure        comply with standard height        prevent work being carried out
their stand number is clearly        regulations. In the interest of    by, or on behalf of, any
displayed. Space only stands         the Exhibition as a whole the      Exhibitor who has not
will not automatically receive a     Organisers reserve the right to    submitted stand design
stand number by the                  determine the position of any      drawings in accordance with
Organisers. Please include the       two-storey structure within a      these regulations.
stand number on your stand           stand.
drawing.                             Two-storey stand structures        4.2.5.19 Messe Frankfurt
To order a stand number from         (1) Upon request, Messe            Structural Regulation
the organisers, please find an       Frankfurt, Event Engineering       The stand approval for all
order form in Messe Frankfurt        Department, can give               structures with walls over 4m
Serviceshop under Stand              permission for a Two-storey        in height, platforms higher
Information - Event                  construction. At its discretion,   than 20cm, moving
Information - Stand                  Messe Frankfurt reserves the       components, closed ceilings
Construction.                        right to refuse permission for     and/or glass constructions
The Organisers reserve the           Two-storey constructions in        (please also see IMEX Technical
right to affix stand numbers or      the interests of the overall       Guidelines point 4.2) will be
directional signs on any stand       appearance of the exhibition       conducted by a Messe
in any position.                     hall or for safety reasons.        Frankfurt structural engineer.
                                     (2) An appropriate application     Depending on the structural
4.2.5.18. Two-Storey Stands          for planning permission,           complexity the approval charge
Written application for              including the necessary            will be in excess of EUR 330
permission to design stands of       documents (layout, ground-         (+German VAT). Please make
two storeys must be made to          plan and sectional sketches,       sure to always have the
the Organisers no later than 6       building specifications and        structural calculations on the
weeks prior to the Exhibition.       checked static calculations),      stand. If you cannot provide
Please include stand drawings.       must be send no later than 6       these to the Messe Frankfurt
The stand drawings must show         weeks prior to the exhibition to   engineer on demand the
the form and dimension of            Organising@imexexhibitions.co      engineer will do the structural
every structural member with         m.                                 calculation which will incur
appropriate general                  For regulations on two storey      additional charges.
arrangement plan, sections and       stand structures please            Please also pay careful
elevations, including full details   especially see points 4.2.1.       attention to the new sections
of stairways. All second storeys     (Inspection and approval of        regarding suspension points
should be used for                   structures requiring               and chain hoists in section
entertainment purposes only          construction permits), 4.9.2.      4.7.6 of the IMEX Technical
and not for exhibition display       (Restrictions applying to stand    Guidelines.
purposes. All drawings must be       superstructures, safety
to scale. All two storey stands      clearances and the heights of
must fully comply with the           interior rooms), 4.9.3. (Traffic
Landlord’s regulations as            loadings/load-bearing
outlined in the enclosed IMEX        capacities) and 4.9.4. (Escape
Technical Guidelines. Two-

                                                   14
Technical Guidelines

HEALTH AND SAFETY                 Please see 4.4.1.1 in the IMEX     compliance must be kept at the
REGULATIONS                       Technical Guidelines for further   stand.
                                  details.                           Please note materials such as
4.2.5.20. Divided Sites /                                            rigid polystyrene foam
Finishing back of stands          4.2.5.22. Open Ceilings            (styrofoam), PVC,
On divided sites, where two or    To ensure that sprinkler           Polycarbonate or similar that
more stands are positioned        protection is not impaired, all    are readily Inflammable, drip
directly adjacent to one          stands must always be open at      while burning or form toxic
another, exhibitors are           the top.                           gases shall not be used! The
responsible for erecting and      Ceilings are to be considered      corresponding certificate(s)
decorating adjoining walls to a   open if no more than 50% per       must be available on site if
minimum height of 2.5m.           each m² of the roofed area is      needed by a representative of
Elements above this height,       covered, i.e. of each individual   Messe Frankfurt or other
which directly overlook a         sqm is closed. Sprinkler-          legible authorities.
neighbouring exhibit, must be     compatible ceiling materials
finished in plain and even        with a mesh size of at least       4.2.5.24. Closed Ceilings
white to a high standard or set   2x4mm or 3x3mm are                 Up to 30sqm of contiguous
back within the stand by 1m. In   permissible. Tarpaulins are to     ceiling area may be covered for
the event that the exhibitor      be hung horizontally and only      one stand without any
fails to erect decorate such      in one layer. Tarpaulins should    additional measures being
walls to the Organisers’          not be allowed to sag.             necessary, however this should
satisfaction, the Organisers                                         not exceed 50% of the stand
reserve the right to remedy                                          area. In order to ensure that
such walls at the expense of                                         multiple ceiling areas together
the Exhibitor. The minimum                                           do not exceed the maximum
height for dividing walls is                                         size of 30sqm, a distance of at
2.5m. THE MAXIMUM HEIGHT                                             least 1.50m from the edge of
FOR DIVIDING WALLS OF                                                the stand is to be maintained
SINGLE STOREY STANDS IS                                              at all times. It is also possible to
6.0m.                                                                have multiple ceiling areas of
                                                                     up to 30sqm within a single
4.2.5.21. Inflammable                                                exhibition stand, as long as a
Material / Roof Materials                                            minimum distance of 3.00m is
All material used on the                                             maintained between each
construction of any stand,                                           ceiling area.
interior fittings and drapes                                         If multiple ceiling areas are
must be hardly-inflammable        4.2.5.23. Requirements for         placed next to one another
according to DIN 4102 (B1) or     ceiling materials                  (including across multiple
EN 13501-1 in German or           All stand ceiling materials must   stands), resulting in a total area
English language. All stand       comply with construction           of larger than 30sqm, suitable
construction material, displays   materials class B1 of DIN 4102,    compensatory measures are
and furniture must be installed   and/or class C of EN 13501-1 in    required. Please see the IMEX
to the satisfaction of the        German or English language,        Technical Guidelines section
authorities. Please note that     i.e. they must be flame-           4.4.1, Table 1 for full details.
the venue does NOT allow the      retardant and must not drip        If the necessary requirements
display of cardboard furniture    while burning or generate toxic    are not met the installation of
on stands.                        gases. A copy of proof of          corresponding compensatory
                                                                     facilities (e.g. fire alarm system,

                                                 15
Technical Guidelines

wall hydrant, visual/acoustic      than 6 weeks before the            60327 Frankfurt am Main,
alarm, automated smoke             exhibition to                      Germany
extraction system, sprinkler       organising@imexexhibitions.com.    Birgit Schoenberg
system) is to be performed by
                                                                      Tel: + 49 69 75 75-61 18
Messe Frankfurt contractors        4.2.5.26. Shell Scheme Stands
and entails a fee charged to the                                      Fax: + 49 69 75 75-65 28
                                                                      imex-fairconstruction@messefrankfurt.com
exhibitor.                         To find out how you can
                                                                      www.fairconstruction.com
For stands with a closed ceiling   customise your Shell Scheme
exceeding 30sqm a special                                             Technical Data of Exhibition
                                   Stand, please refer to the Shell
permit is required.                                                   Hall 8 as well as Full Technical
                                   Scheme Customisation
All requirements relating to the                                      Guidelines are available to
                                   Opportunities Brochure.
installation of closed ceilings                                       download from Messe
can be found from item 4 in        To place your order for items
                                                                      Frankfurt Serviceshop - Stand
Tables 1 and 2, of the IMEX        such as wall graphics, coloured
                                                                      Information - Event
Technical Guidelines section.      carpet, fascia board with your
                                                                      Information - Stand
                                   company logo and others,
                                                                      Construction
                                   please use the Stand
                                   Configurator by clicking here:
4.2.5.25. Stand plan approval                                         For further information please
                                   https://www.fairconstruction.c
process                                                               contact:
In order to receive building       om/messeffmstorefront/ffm/e
permission, all stand drawings -   n/leistungsauswahl/page
                                                                      Messe Frankfurt Venue GmbH
including the necessary
documentation of layout,                                              Anette Berz
                                   The official shell scheme
ground plan, dimensions,                                              Telephone +49 69 75 75-57 86
                                   contractor is:
building and material                                                 Fax +49 69 75 75-63 87
specifications, statistic                                             anette.berz@messefrankfurt.c
calculation, sectional sketches,   Messe Frankfurt Medien und
                                                                      om
all double-storey stands,          Service GmbH
ceilings above 30m² and            Ludwig-Erhard-Anlage 1
platforms >20cm - need to be
submitted for approval no later

                                                 16
Technical Guidelines

4.3. Construction heights

The maximum construction              may be special restrictions in    rear sides of stands adjacent to
heights for stands, rigging and       particular halls. All             neighbouring stands must be
advertising can be found at           measurements must be              kept smooth and be white in
www.messefrankfurt.com.               checked on site and Messe         colour from a height of 2.50 m.
Advertising media, logos, etc.,       Frankfurt assumes no liability    Deviations are only possible
must be positioned at least 1         for figures being correct. The    with the agreement of
metre from the border with            clear height of inside areas      neighbouring stands.
the neighbouring stand. There         must be at least 2.30 m. The

4.4 Fire protection and safety regulations

4.4.1 Fire protection                 Should the operation of these     Frankfurt Venue GmbH’s
regulations                           fire protection systems be        technical Project Management.
The use of open fires and             impaired by stand construction    Please consult the following
flames is prohibited.                 work (e.g. by closed ceilings),   Tables 1 and 2 for the
Exhibition halls are equipped         exhibitors must undertake         necessary measures. Closed
with fire alarms and fire             additional measures in            ceilings are not permitted in
extinguishing systems.                agreement with Messe              foyers.

                                                     17
Technical Guidelines

Table 1: Fire protection programme for one-storey exhibition stands with closed GF ceilings and two-
storey exhibition stands with open TF ceilings (GF = ground floor, TF = top floor)

Ceiling area             0 - 30 m²             31 - 100 m²           101 - 200 m²                      201 - 400 m²                      401 - 1000 m²

Fire protection measures
Stand construction-      Minimum B1,           Minimum B1,           Minimum B1,                       Minimum B1,                       Minimum B1,
materials incl. ceilings flame retardant       flame retardant       flame retardant                   flame retardant                   flame retardant

Stairs                   Minimum B1,           Minimum B1,           Minimum B1,                       Minimum B1,                       Minimum B1,
                         flame retardant       flame retardant       flame retardant                   flame retardant                   flame retardant

Emergency escape         GF:                   GF:                   GF:                               GF:                               GF:
route length             max 20 m to aisle     max 20 m to aisle     max 20 m to aisle                 max 20 m to aisle                 max 20 m to aisle
                         TF:                   TF:                   TF:                               TF:                               TF:
                         max 20 m to aisle     max 20 m to aisle     max 20 m to aisle                 max 20 m to aisle                 max 20 m to aisle

Exits from exhibition    GF: one; 0.9 m        GF: one; 0.9 m        GF: Two, opposite one an-         GF: Two, opposite one an-         GF: Two, opposite one an-
stands or from rooms     TF: one flight of     TF: one flight of     other,                            other,                            other,
located on stands        stairs; 0.9 m         stairs; 0.9 m         < 200 m2: 0.9 m                   < 200 m2: 0.9 m                   < 200 m2: 0.9 m
(minimum width)                                                      > 200 pers: min. 1.2 m + 0.6 m    > 200 pers: min. 1.2 m + 0.6 m    > 200 pers: min. 1.2 m + 0.6 m
                                                                     for each additional 100 pers.     for each additional 100 pers.     for each additional 100 pers.
                                                                     TF: Two flights of stairs oppo-   TF: Two flights of stairs oppo-   TF: Two flights of stairs oppo-
                                                                     site one another, each < 200      site one another, each < 200      site one another, each < 200
                                                                     m2: 0.9 m                         m2: 0.9 m                         m2: 0.9 m
                                                                     > 200 pers: min 1.2 m + 0.6 m     > 200 pers: min 1.2 m + 0.6 m     > 200 pers: min 1.2 m + 0.6 m
                                                                     for each additional 100 pers.     for each additional 100 pers.     for each additional 100 pers.

Emergency escape         Yes                   Yes                   Yes                               Yes                               Yes
route signage                                  Escape sign lights    Emergency lighting                Emergency lighting                Emergency lighting

Fire extinguishers       GF: Yes               GF: Yes               GF: Yes                           GF: Yes                           GF: Yes
                         TF: Yes 1+1 p. stairs TF: Yes 1+1 p. stairs TF: Yes 1 + 1 per stairs          TF: Yes 1 + 1 per stairs          TF: Yes 1 + 1 per stairs

Fire alarm system        GF: No                GF: Yes               GF: Yes                           GF: Yes                           GF: Yes
                         TF: No                TF: No                TF: No                            TF: No                            TF: No

Acoustic/visual alarm    GF: No                GF: No                GF: No                            GF: No                            GF: Yes
                         TF: No                TF: Yes               TF: Yes                           TF: Yes                           TF: Yes

Wall hydrant ”S“         GF: No                GF: No                GF: Yes, one                      GF: Yes, two                      GF: Yes, three
at stand                 TF: No                TF: No                TF: No                            TF: No                            OG: Yes, three

Smoke removal            GF: No                GF: No                GF: No                            GF: Yes                           GF: Yes
                         TF: No                TF: No                TF: No                            TF: No                            TF: No
Sprinkling               GF: No                GF: No                GF: No                            GF: No                            GF: Yes
                         TF: No                TF: No                TF: No                            TF: No                            TF: No

Please note: If there is no top storey used by people, the corresponding requirements for the top storey do not apply.

                                                                          18
Technical Guidelines

Table 2: Fire protection programme for two-storey exhibition stands with closed GF ceilings and closed TF
ceilings (GF = ground floor, TF = top floor)

Ceiling area               0 - 30 m²             31 - 100 m²           101 - 200 m²                      201 - 400 m²                      401 - 1000 m²

Fire protection measures
Stand construction-        Minimum B1,           Minimum B1,           Minimum B1,                       Minimum B1,                       Minimum B1,
materials incl. ceilings   flame retardant       flame retardant       flame retardant                   flame retardant                   flame retardant

Stairs                     Minimum B1,           Minimum B1,           Minimum B1,                       Minimum B1,                       Minimum B1,
                           flame retardant       flame retardant       flame retardant                   flame retardant                   flame retardant

Emergency escape           GF:                   GF:                   GF:                               GF:                               GF:
route length               max 20 m to aisle     max 20 m to aisle     max 20 m to aisle                 max 20 m to aisle                 max 20 m to aisle
                           TF:                   TF:                   TF:                               TF:                               TF:
                           max 20 m to aisle     max 20 m to aisle     max 20 m to aisle                 max 20 m to aisle                 max 20 m to aisle

Exits from exhibition      GF: one; 0.9 m        GF: one; 0.9 m        GF: Two, opposite one an-         GF: Two, opposite one an-         GF: Two, opposite one an-
stands or from rooms       TF: one flight of     TF: one flight of     other,                            other,                            other,
located on stands          stairs; 0.9 m         stairs; 0.9 m         < 200 m2: 0.9 m                   < 200 m2: 0.9 m                   < 200 m2: 0.9 m
(minimum width)                                                        > 200 pers: min. 1.2 m + 0.6 m    > 200 pers: min. 1.2 m + 0.6 m    > 200 pers: min. 1.2 m + 0.6 m
                                                                       for each additional 100 pers.     for each additional 100 pers.     for each additional 100 pers.
                                                                       TF: Two flights of stairs oppo-   TF: Two flights of stairs oppo-   TF: Two flights of stairs oppo-
                                                                       site one another, each < 200      site one another, each < 200      site one another, each < 200
                                                                       m2: 0.9 m                         m2: 0.9 m                         m2: 0.9 m
                                                                       > 200 pers: min 1.2 m + 0.6 m     > 200 pers: min 1.2 m + 0.6 m     > 200 pers: min 1.2 m + 0.6 m
                                                                       for each additional 100 pers.     for each additional 100 pers.     for each additional 100 pers.

Emergency escape           Yes                   Yes                   Yes                               Yes                               Yes
route signage                                    Escape sign lights    Emergency lighting                Emergency lighting                Emergency lighting

Fire extinguishers         GF: Yes               GF: Yes               GF: Yes                           GF: Yes                           GF: Yes
                           TF: Yes 1+1 p. stairs TF: Yes 1+1 p. stairs TF: Yes 1 + 1 per stairs          TF: Yes 1 + 1 per stairs          TF: Yes 1 + 1 per stairs

Fire alarm system          GF: No                GF: Yes               GF: Yes                           GF: Yes                           GF: Yes
                           TF: No                TF: Yes               TF: Yes                           TF: Yes                           TF: Yes

Acoustic/visual alarm      GF: No                GF: No                GF: No                            GF: No                            GF: Yes
                           TF: No                TF: Yes               TF: Yes                           TF: Yes                           TF: Yes

Wall hydrant ”S“           GF: No                GF: No                GF: Yes, one                      GF: Yes, two                      GF: Yes, three
at stand                   TF: No                TF: No                TF: Yes, one                      TF: Yes, two                      TF: Yes, three
Smoke removal              GF: No                GF: No                GF: No                            GF: Yes                           GF: Yes
                           TF: No                TF: No                TF: No                            TF: Yes                           TF: Yes

Sprinkling                 GF: No
                           TF: No                GF: No                GF: No                            GF: No                            GF: Yes
                                                 TF: No                TF: No                            TF: No                            TF: Yes

                                                                            19
Technical Guidelines

Explanations for Table 1 and 2

General remarks / Area data           reduce the effectiveness of      be billed to those who caused
Two-storey structures and the         the sprinkler system in the      them, including expenses for
installation of closed ceilings       exhibition hall. It is also      the affected neighbouring
are only possible with the            possible to have multiple        stand.
consent of Messe Frankfurt            ceiling areas of up to 30 m²     The top storey must always be
Venue GmbH’s Technical                within a single exhibition       left open to ensure that the
Project Management.                   stand, as long as a              effectiveness of sprinkler
Area data in m2 refers in each        minimum distance of 3.00 m       systems is not impaired. If the
case to the closed ceiling area       is maintained between each       ceilings of top storeys are
per storey; a rating in sections      ceiling area. In order to        closed, the additional
may be necessary. For stands          ensure that multiple ceiling     requirements set out in Table 2
with closed ceilings measuring        areas taken together do not      shall apply. Please also see
1,000 m2 or over, an individual       exceed the maxi- mum size        item 4.4.2. Closed ceilings are
fire protection concept based         of 30 m², a distance of at       not permitted in foyers.
on the Messe Frankfurt                least 1.50 m from the edge
Technical Guidelines must be          of the stand is to be            Further general explanations:
prepared and submitted to             maintained at all times.
Messe Frankfurt for its consent.   - Closed ceiling areas up to        Stand construction materials,
                                      100 m² in size require an        stairs
Closed ceilings                       automatic fire alarm             All stand construction and
The effectiveness of the              system.                          decorative materials must
sprinkler system (in the           - Closed ceiling areas that are     comply at least with building
exhibition hall) must not be          larger than 100 m² in size       materials class B1 of DIN 4102
reduced by covered or multi-          also require the installation    and/or class B/C s1 d0 of EN
storey exhibition stands.             of wall hydrants for             13501-1, i.e. must be flame
Ceilings are considered to be         immediate fire-fighting          retardant and neither form
open:                                 measures                         toxic gases nor drip while
- if no more than 50% per          - Closed ceiling areas that are     burning. In particular cases,
    each m² of the roofed area        larger than 400 m² require a     special requirements can be
    is covered                        sprinkler system for the area    prescribed for load-bearing
- if sprinkler-compatible             beneath the closed ceiling. It   structural parts on safety
    fabrics with a minimum            is not permissible to place      grounds. All stairways shall
    mesh width of 2 mm x              multiple ceiling next to         comply with DIN 18065.
    4 mm or 3 mm x 3 mm are           areas of up to 400 m² one
    used (no Smoke Out).              another without a sprinkler      Emergency escape routes
    Tarpaulins are to be hung         system. A minimum                The routing and dimensioning
    horizontally and only in one      distance of 5 m (straight        of emergency escape routes
    layer.                            line) must be maintained         are governed by the
Fire protection measures:             between the ceiling areas.       requirements of the H-VStättR
- Up to 30 m² of ceiling area      Should a larger ceiling area        (Hessian guidelines on public
    of each stand may be           result from not observing the       meeting places). Distances
    covered without any            minimum distance, including         within exhibition stands shall
    additional measures being      across multiple stands, the         be measured according to
    necessary, as long as this     expenses incurred for               walking distance.
    does not exceed 50% of the     compensatory measures
    stand area, as this does not   according to Table 1 or 2 will

                                                  20