About eu.bac Über eu.bac Market outlook, business and politics Markt, Wirtschaft und Politik eu.bac System-Auditor training: DIAL is the first ...
←
→
Page content transcription
If your browser does not render page correctly, please read the page content below
About eu.bac Über eu.bac Market outlook, business and politics Markt,Wirtschaft und Politik eu.bac System-Auditor training: Best practice DIAL is the first training centre in Germany Referenzen Products Produkte Trends Trends 3.2015
About eu.bac eu.bac is the European Building Automation and Controls Association. We represent 29 European manufacturers of products for home and building automation. This corresponds to an annual market of approximately € 4,4 billion. With this economic potential, we are Europe’s largest platform dedicated to energy efficiency in buildings. Our Vision “A world where energy efficiency and sustainability in every building is achieved through the optimal application of home and building controls, automation systems and services.” Members of eu.bac zzARAMARK Ireland zzBELIMO Automation AG zzBROEN A/S zzComap SA zzDanfoss A/S zzDelta Dore SA zzDistech Controls zzFrese zzGFR – Gesellschaft für Regelungstechnik und Energieeinsparung m.b.H. zzHAGER CONTROLS SAS zzHERZ Armaturen GmbH Österreich (Zentrale) zzHoneywell Technologies S.à.r.l. zzIMI Hydronic Engineering zzJohnson Controls, Inc. zzKieback&Peter GmbH & Co. KG zzLOYTEC electronics GmbH zzMeibes System Technik GmbH zzOventrop GmbH & Co. KG zzPriva B.V. zzSaia-Burgess Controls AG zzFr. Sauter AG zzSchneider Electric Buildings AB zzSiemens Building Technologies Ltd. zzSonder Regulación, S.A. zzTheben AG zzThermozyklus GmbH & Co. KG zzTrend Control Systems Ltd. zzTridium Europe Ltd. zzWAGO
Content Inhalt 2 Members of eu.bac 2 eu.bac Mitglieder 4 Editorial 4 Editorial About eu.bac Über eu.bac 5 eu.bac System-Auditor Training: DIAL is the First 7 eu.bac System-Auditoren Training: DIAL ist erstes Training Center in Germany Trainingscenter in Deutschland 8 Advocacy in favour of Building Automation 9 Interessenvertretung für Gebäudeautomation & Controls Market outlook, business and politics Markt,Wirtschaft und Politik 10 Systems Automation and Control in the Context 12 Automation und Steuerung von Systemen im of Connected and Intelligent (“Smart”) Buildings: Kontext vernetzter und intelligenter („Smart") Why is 2016 Important? Buildings: Warum ist 2016 wichtig? 14 High Quality System Components in Demand – 16 Hochwertige Systemkomponenten gefragt – Efficient Control Engineering Supports the ErP- Effiziente Regelungstechnik unterstützt gutes label ErP-Labeling Best practice Referenzen 18 WAGO: The Own Business Building in a New 19 WAGO: Das eigene Bürogebäude aus neuem Point of View Blickwinkel 20 Saarland University to become a Model 22 Die Universität des Saarlandes wird zum Energy Campus Energie-Mustercampus 24 HVAC Upgrades with 2,342 QCV Zone Valves in 26 HLK-Modernisierung mit 2.342 Zonenventilen the GENO-Haus Building in Stuttgart QCV im GENO-Haus/Stuttgart Products Produkte 28 Distech Controls Smart Room Control Solution with 29 Distech Controls smarte Raumautomations-Lösung the AllureTM EC-Smart-Comfort Communicating mit dem busfähigen Raumfühler AllureTM Sensor EC-Smart-Comfort 30 New Room Controller for more Comfort and Energy 30 Neuer Raumcontroller für mehr Komfort und Efficiency Energieeffizienz Trends Trends 31 2015 Energy Performance Contracting (EPC) 32 Markttrends 2015 für Energie-Performace- Market Trends in Europe Contracting (EPC) in Europa 33 eu.bac Product Certification – a have to in France 33 eu.bac Produktzertifizierung – In Frankreich ein Muss 34 Imprint 34 Impressum The next issue will be published on 26/02/2016 Die nächste Ausgabe erscheint am 26.02.2016 Insight 3.2015 3
Jean Daniel Napar Editorial Editorial Liebe Leserin, lieber Leser, eu.bac und ACR Association zur interclima + elec Dear reader, Vom 2. bis 6. November wird sich eu.bac wieder auf eu.bac and ACR Association about interclima + elec der internationalen Messe Mondial du Bâtiment, mit BATIMAT, interclima + elec und Idéobain in Paris präsen- From the 2nd until the 6th of November, the eu.bac will be tieren. Sie finden eu.bac und unseren Partner, die ACR present at the international fair Mondial du Bâtiment, with Association, auf einem Gemeinschaftsstand in Halle 3, BATIMAT, interclima + elec and Idéobain, in Paris. You will Stand F45. be able to find the eu.bac and our partner, the ACR Asso- ciation, at a joint stand in exhibit hall 3, booth F45. Rund um das Thema „Gebäude“ ist viel Bewegung. Neue Gesetze, Technologie, Ökologie und Energie, europäische Currently there is a lot of activity around the topic “build- und nationale Richtlinien, Kommunikationstechnologien, ing”. New laws, technologies, ecology and energy, Europe- die Verbreitung erneuerbarer Energien, das Ziel der Ver- an and national guide lines, communication technologies, ringerung der Treibhausgase stellen neue Herausforde- the dissemination of renewable energies and the objective rungen. to reduce the greenhouse gases, provide new challenges. Die Fragen sind auch für die Unternehmen und die Bran- These questions provide, especially for the companies and che, die von der eu.bac vertreten werden, eine Herausfor- sectors the eu.bac represents, a challenge. Both for new derung, sowohl beim Neubau (1% der Gebäude in Frank- buildings (1% of the buildings in France and the EU) and reich und in der EU) als auch bei der Gebäudesanierung. the building refurbishment. Offene standardisierte Kommunikationsprotokolle sind Outspoken and standardized communication protocols are hier die Antwort. Sie vernetzen die unterschiedlichen the answer. They link different devices and systems and Geräte und Anlagen im Gebäude und ermöglichen so enable applications, which will make the building much Anwendungen, die Gebäude effizienter und komfortabler more efficient and comfortable as well as more economic und ihren Betrieb wirtschaftlicher und umweltfreundli- and environmentally friendly. cher machen. It is important, to rapidly develop and spread these appli- Wichtig ist es, diese Anwendungen schnell weiter zu cations, so that they can get to a standard in the building entwickeln und zu verbreiteten, damit sie im Bereich Ge- sector. eu.bac and ACR contribute in this. bäude allgemein zum Standard werden. eu.bac und ACR leisten dabei ihren Beitrag. Yours sincerely, Ihr Jean Daniel Napar Jean Daniel Napar eu.bac President eu.bac Präsident 4 Insight 3.2015
Interior view of the DIAL building Innenansicht DIAL-Gebäude About eu.bac eu.bac System-Auditor Training: DIAL is the First Training Center in Germany How can you run an energy efficient building over a whole building into one energy model, rather it cate- the long term? More and more building owners gorizes each and every room and zone individually. The and operators are asking this question because efficiency classes suffice from F to AA and are rated on enhanced energy efficiency has become one of the a scale from 0 to 100 points relatively. The audit will be most important matters. Thanks to the EN 15232 done by certified “eu.bac system auditors”. norm “energy efficiency from buildings – influ- ence of building management systems and facil- In two days to an eu.bac system-auditor ity management”, building owners can make sure that from implementation, that a building has an Currently DIAL training centers can be found throughout efficient building automation technology system. Germany and are the only educational establishments But is this enough for a long term energy efficient which offer this type of training. Within two days of operation? Can you assess the value of all rooms practical oriented study, the participants learn how to use in the same manner? eu.bac methods. That’s exactly the point where the eu.bac system inter- After the seminar, participants are able to carry out their venes. Different to the EN 15232 norm, the eu.bac sys- first audit as a “junior-auditor”. As soon as the first audi- tem operates on its own process; it does not categorize ting is successfully finished, the “junior-auditor” can then Insight 3.2015 5
be registered as a certificated “eu.bac system-auditor”. Background information about DIAL Therefore the “eu.bac-system-auditor” can secure the energy efficiency usage of a building automation system DIAL was founded in 1989 with a focus on light and from the beginning and throughout the complete life cycle smart building technology. In accordance with their mot- of the system. to, “better architecture through light and automation”, the company works as a multi-vendor knowledge agent, Of course the DIAL office building is eu.bac certificated planner and service provider as well as a software house. and is the only office building throughout Germany which The performance portfolio includes internationally lea- is classified with an AA energy efficiency rating. The re- ding software-tools for light planning such as DIALux and ason for the high energy efficiency rating is the high-tech LUMsearch. Additionally, light measurements for lights building equipment which was planned and used throug- will be made in accredited laboratories, as well as tests hout DIAL’s construction. from BACnet, DALI and KNX products. At the same time, DIAL passes on the knowledge which was acquired from The advantages of training at a DIAL facility are perfectly planning, consulting and scientific research. obvious. Only practically orientated trainers work at DIAL, and are able to pass on this specialized knowledge at Kerstin Niedernüvemann any time. In addition to that, is the eu.bac training, which DIAL GmbH just like any other training at DIAL, is independent and Bahnhofsallee 18 multi-vendor. In addition to advanced training in building D-58507 Lüdenscheid certification, DIAL also instructs in light and smart buil- niedernuevemann@dial.de ding technology. www.dial.de eu.bac training at DIAL eu.bac Training bei DIAL 6 Insight 3.2015
About eu.bac eu.bac System-Auditoren Training: DIAL ist erstes Trainingscenter in Deutschland Wie kann ein Gebäude dauerhaft energieeffizient lage für die hohe Energieeffizienz des Gebäudes ist die betrieben werden? Diese Frage stellen sich immer hochkomplexe technische Gebäudeausrüstung, die auf mehr Gebäudeeigentümer und Betreiber: Denn Basis des Gebäude-System-Design Prozesses von DIAL verbesserte Energieeffizienz in Gebäuden steht geplant und umgesetzt wurde. mehr und mehr im Fokus. Mit Hilfe der Norm EN 15232 „Energieeffizienz von Gebäuden – Einfluss Die Vorteile einer Schulung bei DIAL liegen also auf der von Gebäudeautomation und Gebäudemanage- Hand. Bei DIAL arbeiten ausschließlich praxiserfahrene ment“ können Bauherren bereits sicherstellen, Trainer, die sofort anwendbares Fachwissen vermitteln. dass ein gesamtes Gebäude bei Inbetriebnahme Außerdem ist das eu.bac Training, wie auch alle andere über effiziente Gebäudeautomationstechnologien Schulungen bei DIAL, herstellerneutral und unabhängig. verfügt. Aber reicht dies für den langfristigen Neben Weiterbildungen im Bereich der Gebäudezertifizie- energieeffizienten Betrieb? Und kann man alle rung ist DIAL auch in der Ausbildung von Fachleuten für Räume eines Gebäudes gleichermaßen bewerten? Licht und Smart Building tätig. Genau hier setzt das eu.bac System an. Denn anders als Hintergrundinformationen zu DIAL die EN 15232 basiert das eu.bac System auf einem ge- wichteten Verfahren: Nicht das ganze Gebäude wird ener- DIAL wurde 1989 gegründet und beschäftigt sich getisch klassifiziert, sondern seine einzelnen Räume und schwerpunktmäßig mit Licht und intelligenten Gebäu- Zonen. Die Effizienzklassen der Automatisierung reichen den. Gemäß dem Leitspruch „Bessere Architektur durch von F bis AA und werden über eine Skala von 0 – 100 Licht und Automation“ ist das Unternehmen als herstel- Punkten relativ bewertet. Das Audit wird von zertifizierten lerneutraler Wissensvermittler, Planer, Dienstleister und „eu.bac System-Auditoren“ durchgeführt. Softwarehaus tätig. Das Leistungsportfolio umfasst die für Lichtplanung international führenden Software-Werk- In zwei Tagen zum eu.bac System-Auditor zeuge DIALux und LUMsearch. Darüber hinaus werden in akkreditieren Laboren Lichtmessungen an Lampen Aktuell ist DIAL die deutschlandweit einzige Schulungs- und Leuchten vorgenommen sowie Prüfungen und Tests stätte, die das Training anbietet. In zwei Tagen erlernen von BACnet, DALI und KNX-Produkten durchgeführt. Zu- die Teilnehmer anhand praxisnaher Übungen die Anwen- gleich vermittelt DIAL das in Planung, Beratung und For- dung der eu.bac Methodik. schung erworbene Wissen in Seminaren und Workshops. Nach dem Seminar sind die Absolventen in der Lage, als „Junior-Auditor“ ihr erstes Audit durchzuführen. Sobald die erste Auditierung erfolgreich abgeschlos- sen ist, kann sich der „Junior-Auditor“ als zertifizierter „eu.bac System-Auditor“ registrieren lassen. Somit stellen „eu.bac System-Auditoren“ den energieeffizienten Be- trieb eines Gebäudeautomationssystems sicher – sowohl bei der ersten Inbetriebnahme als auch über den gesam- ten Lebenszyklus einer Anlage. Selbstverständlich ist auch das DIAL Firmengebäude eu.bac zertifiziert – übrigens als deutschlandweit ein- ziges Bürogebäude mit der Effizienzklasse AA. Grund- Insight 3.2015 7
About eu.bac Advocacy in favour of Building Automation & Controls eu.bac’s mission is to create a regulatory environment distributed energy generation while introducing the ability which recognizes that building automation and controls for demand side management. (products, systems and services) can play a key role in improving the energy efficiency and indoor environment Moreover, we have elaborated upon the fact that in- quality of homes, tertiary buildings, and industry. creased volatility in energy supply, caused by greater dependence on weather-based energy sources, can be The role of the Advocacy Panel is to turn this into real- mitigated by using controls to achieve a good balance ity by convincing authorities, both at the EU as well as between consumption and storage. At the same time, we national levels, that the member companies of eu.bac have outlined how our systems can create storage po- can help them achieve their political objectives of mak- tential in homes and buildings by smoothing out the gaps ing a better, more efficient use of energy, decrease CO2 between variable supply and demand. emissions and reduce the need for energy imports. Thus, benefiting consumers by offering increased flexibility in Last but not least, we have actively contributed to all the energy management and improved indoor environment stakeholder’s sessions organized by the Commission quality, with a direct impact on health, comfort, produc- since its publication of the Energy Union Roadmap, early tivity and well-being. in 2015. When the Commission adopted its Energy Union Frame- With legislators focused on building envelope and the work Strategy in February 2015, it recognized that 75% merits of insulation or double/triple glazed windows, it has of the EU’s housing stock is “energy inefficient” and that become a challenge to position the building automation “heating and cooling is the largest single source of energy and controls industry as a key provider of value-added demand in Europe”. And yet, while speaking about energy solutions for the improvement of a buildings’ energy per- efficiency, it did not immediately recognize the significant formance. improvements in the buildings’ energy performance that can be brought about through the use of building automa- The pressure created in recent years by the need to tion and controls. improve the EU’s energy security and to substantially decrease CO2 emissions, is opening a window of oppor- This is what the Advocacy Panel has concentrated upon tunity that we are set to seize upon in order to create op- over the last few months; we have met with a large num- portunities for building owners, consumers as well as the ber of commission officials and member state represen- industry. This is what we will continue to work towards tatives to explain how we can help them meet their politi- in the next few months by reinforcing our external com- cal and economic objectives, and how EU legislation must munication tools as well as creating synergies with other be adapted to enable us to move forward. We are now working group segments within eu.bac. reaching out to the members of the European Parliament for that very purpose. Iliana Axiotiades Chairperson of the eu.bac Advocacy Panel We have discussed with those making policy decisions Director Government & Trade Relations the optimum way in which specific articles of the Energy at Johnson Controls International Performance of Buildings Directive (EPBD) need to be Iliana.Axiotiades@jci.com adjusted, and have explained that they should recon- sider their approach in particular with regard to smart appliances. Even though smart appliances might allow more flexibility for the end-user’s energy consumption they will not help reduce consumption per se as much as automation and controls would. We also described how our products, systems and services can help integrate 8 Insight 3.2015
Über eu.bac Interessenvertretung für Gebäudeautomation Mission der eu.bac ist es, regulatorische Rahmenbedin- Denn auch wenn diese dem Endkunden möglicherweise gungen zu schaffen, die anerkennen, dass Gebäudeauto- mehr Flexibilität beim Energieverbrauch bieten, werden mation (Produkte, Systeme und Dienstleistungen) bei der sie nicht helfen, den Verbrauch an sich zu reduzieren, so Verbesserung von Energieeffizienz und Raumkonditionen wie es Automatisierung und Steuerung können. Wir ha- von Häusern und Gebäuden – privat oder gewerblich – ben auch dargelegt, wie unsere Produkte, Systeme und eine Schlüsselrolle spielen kann. Dienstleistungen mit Einführung der Nachfragesteuerung die Integration der dezentralen Energieerzeugung unter- Die Rolle des Advocacy Panel besteht darin, die Behörden stützen können. auf EU- und nationaler Ebene zu überzeugen, dass die in der eu.bac organisierten Unternehmen ihnen dabei helfen Außerdem haben wir die Tatsache ausgeführt, dass die können, ihre politischen Ziele zu erreichen: mehr Energie- erhöhte Volatilität der Energieversorgung, verursacht effizienz, verringerte CO2-Emissionen und weniger Ener- durch größere Abhängigkeit von Wetter basierten Ener- gieimporte und gleichzeitig Vorteile für die Verbraucher giequellen, mit Steuerungen gemildert werden kann, durch größere Flexibilität beim Energiemanagement und die für ein gutes Gleichgewicht zwischen Verbrauch und bessere Umgebungsbedingungen in ihren Räumen, mit Speicherung sorgen, Gleichzeitig wurde gezeigt, wie un- direkter Auswirkung auf Gesundheit, Komfort und Wohl- sere Systeme das Speicherpotential von Häusern und befinden. Gebäuden nutzen können, um die Spanne zwischen vari- ablem Angebot und variabler Nachfrage zu glätten. Als die Kommission im Februar 2015 ihre Rahmenstra- tegie Energieunion verabschiedete, stellte sie fest, dass Und nicht zuletzt haben wir aktiv an allen Anhörungen der 75% des Wohnungsbestandes in der EU „energiein Interessenträger teilgenommen, die die Kommission seit effizient“ ist und „Heizen und Kühlen ... die größten der Veröffentlichung der Energy Union Roadmap Anfang Verursacher der Energienachfrage in Europa“. Aller- 2015 organisiert hat. dings: Während sie über Energieeffizienz sprach, über- sah sie gleichzeitig die erheblichen Verbesserungen der Bei Gesetzgebern, die auf die Gebäudehülle und die Vor- Gebäude-Energieeffizienz, die mit Gebäudeautomation züge von Isolierung oder doppel- und dreifach-verglasten erzielt werden können. Fenstern fokussiert waren, war es eine Herausforderung, die Branche der Gebäudeautomation als einen Kernan- Da ist es, worauf sich das Advocacy-Panel in den letz- bieter von Mehrwert-Lösungen für die Verbesserung der ten Monaten konzentriert hat: Wir haben uns mit vielen Energieeffizienz von Gebäuden zu positionieren. Offiziellen der Kommission und Vertretern der Mitglied- staaten getroffen, um zu erklären, wie wir sie unterstüt- Der Druck, der in den letzten Jahren durch die Notwen- zen können, ihre politischen und wirtschaftlichen Ziele digkeit entstanden ist, die Energiesicherheit der EU zu zu erreichen, und wie EU-Rechtsvorschriften angepasst verbessern und die CO2-Emissionen wesentlich zu verrin- werden müssen, damit wir dazu in der Lage sind, das zu gern, öffnet uns ein Fenster, das wir als Chance nutzen, tun. Aktuell sprechen wir gleichermaßen die Mitglieder sowohl für die Industrie als auch für Gebäudeeigentümer des Europäischen Parlaments an. und Nutzer. Und das ist, worauf wir in den nächsten Mo- naten weiter hinwirken werden, durch die Stärkung un- Mit den politischen Entscheidungsträgern haben wir serer externen Kommunikationsmittel, aber auch durch über den besten Weg diskutiert, wie bestimmte Artikel den Aufbau von Synergien mit anderen Arbeitsgruppen der Energy Performance of Buildings Directive (EPBD) innerhalb der eu.bac. angepasst werden müssen, und haben begründet, dass sie ihre Vorgehensweise im Hinblick auf intelligente Haushaltsgeräte (smart appliances) überdenken sollten. Insight 3.2015 9
© European Union, Eureka Slide Market outlook, business and politics Systems Automation and Control in the Context of Connected and Intelligent (“Smart”) Buildings: Why is 2016 Important? A process for the review of the Directive 2010/31/EU on encourage “the installation of active control systems such the energy performance of buildings1 (EPBD) has just as automation, control and monitoring systems that aim started and next year will be a crucial period for taking to save energy”. stock of past and current achievements. Areas for reflec- tion include how to enhance its enforcement at national, Buildings become “smart” regional and local level and how best to address the latest technology developments, interconnection capabilities, The “smart” dimension has also found its way into the trends in the building services and urban infrastructure. building sector. Active energy management systems, for example systems that can coordinate heating, lighting It is important to highlight that, already today, several and domestic appliances, factor in climatic and lighting EPBD provisions encourage the implementation of solu- aspects and adapt to the availability of self-generated tions based on improved control and automation systems. energy from renewable sources, are a big step forward In particular with the purpose of optimising the energy towards building energy efficiency. Broadly speaking, use of heating & cooling, ventilation, hot water and light- this “smart” dimension might ease the compliance with ing systems, Member States are obliged to set system re- EPBD not only in relation to the technical building systems quirements in respect of the overall energy performance, provisions (see above) but with others on the promotion the proper installation, and the appropriate dimensioning, of nearly zero-energy buildings and in relation with the adjustment and control of the technical building systems inspection of heating and air-conditioning systems. which are installed in existing buildings. Furthermore it is also required that Member States shall encourage the The actual evolution of “smart” buildings or homes in Eu- introduction of intelligent metering systems (i. e. smart rope has been slower than expected over the last years meters) whenever a building is constructed or undergoes but a large potential remains. Thanks to new innovations major renovation. In addition, the EPBD indicated that, and breakthroughs in the domains of information and where appropriate, Member States may go further and communication technologies (e. g. building “internet of 10 Insight 3.2015
things”), fully automatic systems that could optimise all In a broader policy perspective, the Energy Union Strat- building services are becoming a reality. All aspects of a egy contains both a long-term vision for European energy building’s technical performance, as illustrated by differ- policy for the coming decades, and a concrete set of ent demonstration projects2, could be brought together measures for the Commission. This Strategy recognises through one common Internet-based platform – linking energy efficiency as an energy source in its own right. sensors and devices and optimizing control automatically Now the legislators and policy makers will systematically through the use of analytical software. These new tech- ask if problems can be solved by saving energy first – nologies and applications could bring benefits not only before thinking about increasing imports or building new for safety and health features of the building infrastruc- capacity. ture (e. g. fire detection, access control, intruder alarms, lighting controls, video surveillance, ventilation, humidity, Another priority of the Energy Union Strategy, closely air quality) but potentially as well for other aspects such linked to energy efficiency, is to put the consumer at the as comfort, well-being and environment. “Smart” tech- centre of an integrated internal energy market. The con- nologies such as home automation could give consumers sumer role in this context should not be limited to paying greater influence over their own consumption patterns, bills. We have to enable consumers to play an active role and individual buildings and in the long term districts will in our energy market, easily monitoring and optimising play an active role in local distribution and storage grids. their consumption and shifting it to periods in which ener- gy is cheaper or comes from renewable energy sources. The Energy Union Strategy Innovation is a key element in this context. New technolo- gies and “smart” applications will have a major role on Against this framework, the Commission is following a how consumers use energy in the future. two-track approach: promoting the market up-take of in- novative – “smart” – energy technologies and solutions Santiago González Herraiz and at the same time creating the appropriate regulatory Spanish official currently seconded in DG ENER framework. For the latter, one of the major initiatives is European Commission – Directorate General for Energy the ongoing review of the EPBD, due by end of 2016. As a first step, a public consultation on the evaluation of the 14th September 2015 Directive is currently open and will run until the end of October 2015. The role of building automation, control Opinions expressed in this article are those of the author and monitoring systems is explored directly or indirectly and do not reflect necessarily the positions of the Euro- in this public consultation, notably under those questions pean Commission. linked to demand response; integration into district and city levels, smart cities and heating and cooling net- works; awareness, information and building data; the impact on building systems requirements, operational 1 O J L 153, 18.6.2010, p. 13 2 See study “Reducing energy consumption in building with ICT- management and maintenance. Stakeholders were in- Analysis of data from EU pilot projects-SMART 2013/0073” funded vited to contribute to this consultation, which will inform under the Competitiveness and Innovation Framework Programme the evaluation of the EPBD and the subsequent Impact ICT-Policy Support Programme, together with other sources i.e. Assessment process. HOMES project by Schneider Electric. Santiago González Herraiz © European Union, 2015 Photo: Ansotte Etienne 11
Markt, Wirtschaft und Politik Automation und Steuerung von Systemen im Kontext vernetzter und intelligenter („Smart“) Buildings: Warum ist 2016 wichtig? Gerade wurde ein Verfahren zur Überprüfung der Richt- me (siehe oben) erleichtern, sondern auch bei der Förde- linie 2010/31/EU über die Gesamtenergieeffizienz von rung von Niedrigstenergiegebäuden und bei der Prüfung Gebäuden1 (EPBD) gestartet. Und das nächste Jahr wird von Heizungs- und Klimaanlagen. eine entscheidende Phase bei der Bestandsaufnahme der bisherigen und aktuellen Ergebnisse. Themen sind dabei Die tatsächliche Entwicklung von „smarten“ Gebäuden auch, wie ihre Durchsetzung auf nationaler, regionaler oder Häusern in Europa verlief in den letzten Jahren lang- und lokaler Ebene gefördert und wie neueste technolo- samer als erwartet, es bleibt ein großes Potenzial. Mit den gische Entwicklungen, Vernetzungsmöglichkeiten und Innovationen und Durchbrüchen in den Informations- und Trends in der Haustechnik und städtischen Infrastruktur Kommunikationstechnologien (z. B. „Internet der Dinge“ am besten angegangen werden. im Gebäude) werden vollautomatische Systeme, die die gesamte Haustechnik optimieren könnten, Realität. Wie Es ist hervorzuheben, dass bereits heute mehrere verschiedene Demonstrationsprojekte2 gezeigt haben, EPBD-Bestimmungen die Implementierung von Lösun- könnten alle Aspekte der technischen Performance ei- gen auf Basis von verbesserten Steuerungs- und Auto- nes Gebäudes auf einer gemeinsamen internetbasierten matisierungssysteme fördern. Insbesondere hinsichtlich Plattform zusammen gebracht werden – durch die Ver- der angestrebten Optimierung des Energieverbrauchs knüpfung von Sensoren und Geräten und die Optimierung durch Heizung und Kühlung, Lüftung, Warmwasser und der automatischen Steuerung durch Analysesoftware. Beleuchtung sind die Mitgliedstaaten verpflichtet, An- Diese neuen Technologien und Anwendungen wären nicht forderungen für die Gesamtenergieeffizienz, für die ord- nur für die Bereiche der Gebäudeinfrastruktur vorteilhaft, nungsgemäße Installation und für die richtige Auslegung, die für Sicherheit und Gesundheit sorgen (z. B. Brandmel- Anpassung und Überwachung der technischen Gebäude- dung, Zutrittskontrolle, Einbruchalarm, Lichtsteuerung, systeme, die in bestehenden Gebäuden installiert wer- Videoüberwachung, Lüftung, Luftfeuchte, Luftqualität), den, festzulegen. sondern auch für Komfort, Wohlbefinden und Umwelt. Mit „smarten“ Technologien wie der Home Automation Darüber hinaus wird gefordert, dass die Mitgliedstaaten erhielten die Verbraucher mehr Einfluss auf ihre eigenen die Einführung intelligenter Messsysteme (z. B. Smart Verbrauchsgewohnheiten und Einzel-Gebäude und lang- Meter) unterstützen, wenn Gebäude neu errichtet oder fristig auch Ortsteile könnten eine aktive Rolle in lokalen umfassend renoviert werden. Außerdem weist die EPBD Verteilungs- und Speicher-Netzen spielen. darauf hin, dass die Mitgliedstaaten „die Installation ak- tiver Steuerungssysteme, wie auf Energieeinsparungen Die EU Energie-Strategie ausgelegte Automatisierungs-, Regelungs- und Überwa- chungssysteme“, unterstützen können. Vor diesem Rahmen verfolgt die Kommission einen zwei- gleisigen Ansatz: Förderung der Markteinführung innova- Gebäude werden „smart“ tiver – „smarter“ – Energietechnologien und -lösungen und parallel die Schaffung des geeigneten Rechtsrah- Die „smarte“ Dimension hat auch in der Baubranche mens. Für letzteres ist eines der wichtigsten Vorhaben Einzug gehalten. Ein großer Schritt Richtung Gebäu- die aktuelle Überprüfung der EPBD, abzuschließen bis de-Energieeffizienz sind zum Beispiel aktive Energie- Ende 2016. Als erster Schritt läuft bis Ende Oktober 2015 managementsysteme, die Heizung, Beleuchtung und eine öffentliche Anhörung über die Bewertung der Richtli- Haushaltsgeräte unter Klimatisierungs- und Beleuch- nie. Die Rolle der Gebäudeautomation, Steuerungs- und tungs-Aspekten koordinieren und an die Verfügbarkeit Überwachungssysteme wird direkt oder indirekt in die- selbst erzeugter Energie aus erneuerbaren Quellen ser öffentlichen Anhörung untersucht, besonders unter anpassen können. Allgemein formuliert könnte diese den Fragen im Zusammenhang mit „demand response“: „smarte“ Dimension die Einhaltung der EPBD nicht allein Integration in Viertel- und Stadtebene, Smart Cities und bezüglich der Vorschriften für technische Gebäudesyste- Heiz- und Kühlnetze; Sensibilisierung, Information und 12 Insight 3.2015
THZ_61x180_2015_1_THZ 21.01.15 13:34 Seite Die intelligente Einzelraumregelung – Gebäudedaten; die Auswirkungen auf die Anforderungen auch für Radiatoren an Gebäude-Systeme, Betriebsführung und Wartung. Die Interessenvertreter wurden zu dieser Anhörung eingela- den, die in die Bewertung der EPBD und den anschlie- ßende Folgenabschätzungsprozess einfließt. In einer umfassenderen politischen Sichtweise enthält die EU Energie-Strategie sowohl eine langfristige Vision für die europäische Energiepolitik für die kommenden Jahr- zehnte als auch ein konkretes Maßnahmenpaket für die Kommission. Diese Strategie erkennt die Energieeffizienz als eigenständige Energiequelle. Jetzt werden die Ge- setzgeber und politische Entscheidungsträger regelmä- ßig fragen, ob Probleme nicht zuerst durch Energiespa- ren gelöst werden können – bevor man über wachsende Einfuhren oder den Aufbau neuer Kapazitäten nachdenkt. + Intelligent, schnell und Eine weitere Priorität der EU Energie-Strategie, die eng effizient mit der Energieeffizienz verbunden ist, besteht darin, den Verbraucher in den Mittelpunkt eines integrierten Ener- + Autoadaptiv und giebinnenmarktes zu stellen. Die Rolle des Verbrauchers ist in diesem Zusammenhang nicht auf die Zahlung von energiesparend Rechnungen beschränkt. Wir müssen den Verbrauchern ermöglichen, eine aktive Rolle im Energiemarkt zu spie- = Komfort und len, ihren Verbrauch leicht zu überwachen und zu opti- Wirtschaftlichkeit mieren und in Zeiten zu verschieben, in denen Energie billiger ist oder aus erneuerbaren Energiequellen stammt. Innovation ist in diesem Zusammenhang ein Schlüssel- element. Neue Technologien und „intelligente“ Anwen- dungen werden eine wichtige Rolle dabei spielen, wie die Verbraucher in der Zukunft Energie nutzen. Die in diesem Beitrag geäußerten Ansichten sind die Wir sind dabei! des Autors und geben nicht unbedingt die Position der Europäischen Kommission wieder. eu.bac Zertifizierung 1 OJ L 153, 18.6.2010, S. 13 für geprüfte 2 Siehe Studie „Reducing energy consumption in building with Qualität, ICT-Analysis of data from EU pilot projects-SMART 2013/0073“ Regelgenauigkeit gefördert im Rahmen „ICT Policy Support Programme“ des „Com- und petitiveness and Innovation Framework Programme“, zusammen Energieeffizienz mit weiteren Quellen, d.h. Projekt „HOMES“ von Schneider Electric. Thermozyklus GmbH & Co. KG Grubmühlerfeldstraße 54, D-82131 Gauting Tel.: 0 89 / 8 95 56 23 - 0 info@thermozyklus.com www.thermozyklus.com
The ErP-label for composite plants Das ErP-Label für Verbundanlagen Electronic radiator controller HR92 with eu.bac energy efficiency label Elektronischer Heizkörperregler HR92 mit eu.bac Energieeffizienz-Label Market outlook, business and politics High Quality System Components in Demand – Efficient Control Engineering Supports the ErP-label In September 2015, the European guideline ERP (Energy Important: The guideline motivates the installer, to syn- related Products Directive) for heating systems and water chronize the different system components very individu- heaters became enforced. An energy consumption label ally for every place and therefore to use different products for a heating system shall increase the sale and installati- from different manufacturers. That means that every on of highly efficient products. An outstanding efficiently component can be adapted to various building situations. control system leads to a better overall evaluation of a heating system. Based upon the classification of different products, an installer can show how a high quality energy efficient pro- Installers shall continue to combine products duct positively changes the energy cost and the overall from different manufacturers efficiency as well as what the comparison of a less well balanced product would be. The ErP-guideline makes a difference between a label for a single product, which is delivered by the manufacturer, Single components enable higher energy efficiency and a system label for combination systems, for example, a heating system including a heater, solar equipment, a Products and components with high quality technical possibility of storage and single or multiple thermostats. characteristics enable the possibility of acquiring a higher For heating controls there are eight different efficiency class system label (e. g. from A to A++). Thus, it is pos- classes, in which a manufacturer has to classify its pro- sible to plan heating solutions with a budget and fitting ducts. situation individually tailored to each client. 14 Insight 3.2015
services, we are able to offer with our products the per- fect starting situation, for the highest energy efficiency for heating systems”, explained Volker Galonske, Marke- ting Manager from Honeywell building services. The VdZ-Software helped with the preparation of the label To help installation technicians with the presentation of the composite plant, the VdZ – a German forum asso- ciation for energy efficiency in building technology e.V. – developed the portal HEIZUNGSlabel (heating label) – a central database with connection options for shop systems from the wholesale market and craftsman soft- ware. Next to the access over the commercial software, the craftsman can also access the data and the calcula- tion tool directly over the portal-website. With this tool, it becomes possible to show and compare the different system types and their energy efficiency, in a consulta- tion meeting. Honeywell building services is a contract partner of HEIZUNGSlabel. More information under www.heizungslabel.de. Volker Galonske The installer lists all information about the system Honeywell GmbH, Haustechnik components of a heating system into a data sheet and info.haustechnik@honeywell.com receives therefore the system label. www.honeywell-haustechnik.de Der Installateur trägt alle Angaben zu den Systemkom- ponenten eines Heizsystems in ein Datenblatt ein und erhält damit das Systemlabel. Honeywell products for compound systems fulfill the high standards of the ErP-guideline. They stand out due to their excellent energy efficiency. For example the intelligent individual room control system “evohome”, with its OpenTherm interface for modulating heat generator control, manages to attain a category VIII, which is the best ErP-class possible. Honeywell’s SDC- controller in the Smile-series reaches a ErP-category VI, and the programmable room thermostat CM, from Ho- neywell, is categorized in category IV. “With an efficient control technology it is possible to reach a very high ErP-label. As a specialist for building Insight 3.2015 15
Markt, Wirtschaft und Politik Hochwertige Systemkomponenten gefragt – Effiziente Regelungstechnik unterstützt gutes ErP-Labeling Im September 2015 trat die europäische ErP-Richtlinie Die Honeywell-Produkte für Verbundanlagen erfüllen die (Energy related Products Directive) für Raumheiz- und hohen Anforderungen der ErP-Richtlinie. Sie zeichnen Kombiheizgeräte sowie Warmwasserbereiter in Kraft. sich unter anderem durch eine sehr hohe Energieeffizienz Ein Energieverbrauchslabel für das Heizsystem soll den aus. Beispielsweise erreicht das intelligente Einzelraum- Verkauf und die Installation möglichst effizienter Produk- regelungssystem evohome mit OpenTherm-Schnittstelle te unterstützen. Eine als besonders effizient eingestufte zur modulierenden Wärmeerzeugeransteuerung Katego- Regelungstechnik sorgt dabei für eine bessere Gesamt- rie VIII, also die beste ErP-Klasse. Die Honeywell SDC- bewertung des Heizsystems. Regler der Smile-Reihe kommen auf ErP-Klasse VI, die programmierbaren Raumthermostate CM von Honeywell Installateur soll weiterhin Produkte verschiedener sind in Klasse IV eingeordnet. „Mit einer effizienten Rege- Hersteller kombinieren lungstechnik kann eine sehr hohe Stufe des ErP-Labels erzielt werden. Als Spezialist für Haustechnik bieten wir Die ErP-Richtlinie unterscheidet zwischen einem Label mit unseren Produkten die beste Ausgangslage für die für Einzelprodukte, das vom Hersteller ausgestellt wird, höchste Energieeffizienz des Heizsystems“, erklärt Volker und dem Systemlabel für Verbundanlagen – zum Beispiel Galonske, Marketingleiter von Honeywell Haustechnik. Heizsysteme bestehend aus Heizgerät(en), Solaranlage, Speicher und einem oder mehreren Temperaturreglern. VdZ-Software hilft bei Erstellung des Labels Für die Regelungstechnik gibt es acht Effizienzklassen, in die der Hersteller seine Produkte einzuordnen hat. Um Installateure bei der Ausstellung des Verbundanla- genlabels zu unterstützen, hat der Verband VdZ (Forum Wichtig ist: Die Richtlinie motiviert den Heizungsbauer/ für Energieeffizienz in der Gebäudetechnik e.V.) das Installateur, die Systemkomponenten vor Ort individuell Portal HEIZUNGSlabel entwickelt – eine zentrale Da- aufeinander abgestimmt einzusetzen und Produkte ver- tenbank mit Anbindungsmöglichkeiten für Shopsysteme schiedener Hersteller zu kombinieren. Das heißt, jede des Großhandels und die Handwerkersoftware. Neben Komponente kann je nach Bedarf auf die jeweilige Ge- dem Zugang über die kaufmännische Software kann der bäudesituation angepasst werden. Ausgehend von der Handwerker auch direkt über die Portal-Website auf die Klassifizierung verschiedener Produkte kann der Ins- Daten und das Berechnungstool zugreifen. So können tallateur beispielsweise zeigen, wie sich eine qualitativ beispielsweise in einem Beratungsgespräch mit dem hochwertige Regelung in Sachen Energieeffizienz und Kunden verschiedene Anlagentypen und ihre Energiela- Energiekostenersparnis positiv auf die Gesamteffizienz bel aufgezeigt und verglichen werden. Honeywell Haus- auswirkt und von weniger gut abgestimmten Produkten technik ist Vertragspartner von HEIZUNGSlabel. unterscheidet. Mehr unter www.heizungslabel.de. Einzelkomponenten ermöglichen höhere Energieef- fizienzklassen Volker Galonske Honeywell GmbH, Haustechnik Produkte und Komponenten mit sehr guten technischen info.haustechnik@honeywell.com Eigenschaften ermöglichen den Sprung in höhere Klas- www.honeywell-haustechnik.de sen des Systemlabels (z. B. von A auf A++). Individuelle Verbundanlagen lassen sich so optimal für die konkrete Einbausituation und das Budget des Kunden planen und erstellen. 16 Insight 3.2015
Best practice WAGO: The Own Business Building in a New Point of View Five floors, originally constructed in 2011, and a roughly The building V3 was subsequently rated an A, a good 5,000 square meter surface area. These are the three result considering it is a four year old existing building. significant pieces of information which describe the ob- In the future efficiency gains are also possible, provided ject of a building investigation termed V3 at WAGO, in eu.bac uses key indicators (KPI) for single system parts Minden. The audit was made by some new auditors from or uses the weather forecast for operational optimization. their own company, who had passed their master’s cer- tificate. For WAGO, the rating provides a very good business re- silient base from which to calculate building efficiency in- One of the special features of this office and develop- vestments. “Because we compare systematically, we get ment building is that because of its connection to a pro- the results which show where modernization in building prietary local heating network, no additional heating is stock are profitable”, explains auditor Martin Hardenfels, provided. Therefore a composite plant consisting of a gas director for project sales at WAGO. boiler and a ground-source heating pump working in the neighboring building, feeds a distributor with Zortström- The use of the systematical eu.bac-rating offers the technology, and is able to supply the other users in the company a very good test field, for testing and defining system as well. On the ventilation system side, there is a operations. The advantage for their clients is that future central plant with adjusted heat recovery. WAGO products will be developed respective to current energy efficiency requirements. These are particularly The building is equipped with building automation and a software-functions, as Martin Hardenfels explains, which meter data logging system, which gives feedback about enable efficient functions with minimal effort to lay the the operating conditions. Daylight depending lighting, ground-work for an efficient company. automatic sun protection and the room temperature are flexibly controlled and on demand. For the room automa- Martin Hardenfels tion system, the WAGO-flexROOM® is used; this com- Leiter Projektvertrieb bines the three systems into one device. The lighting is Gebäudetechnik realized with DALI, multiple sensors within the work place WAGO Kontakttechnik record the luminance and the presence of employees. GmbH & Co. KG www.wago.com The room temperature is controlled by heaters and cooling registers in front of the air outlets with valves. All additional sensors are connected over the EnOcean- function towards the single room control. According to the energy certificate, the building has an energy demand that is under the EnEV-requirement. But how efficiently is the technology used? With an analysis in accordance to the eu.bac-classifica- tion system, it became clear that the ventilation system brings the highest reduction, because the building is partly provided with a constant volume flow. In this case a retrofit is very difficult for economic reasons. Altogether the audit showed that the systems are controlled opti- mally at the operating points by facility management. The local heat networks with heat recovery as well as the thermo-automatic sun protection also account for the efficiency. The existing building V3 of the WAGO-headquarters in Minden. New auditors from the company analyzed the office- and development building and rated it as an A. 18 Insight 3.2015
Referenzen WAGO: das eigene Bürogebäude aus neuem Blickwinkel Fünfgeschossig, Baujahr 2011, rund 5.000 Quadratme- wirtschaftlich nur schwer darstellen. Insgesamt zeigte ter Nutzfläche: Das sind die drei wesentlichen Eckdaten, das Audit, dass die Anlagen durch das Facility Manage- die den Untersuchungsgegenstand – das Gebäude mit ment in optimalen Betriebspunkten geführt werden. Hier- der Bezeichnung V3 bei WAGO in Minden – kennzeich- zu zählen der Nahwärmeverbund mit Wärmerückgewin- nen. Das Audit haben frischgebackene Auditoren aus nung sowie die Thermoautomatik des Sonnenschutzes. dem eigenen Unternehmen durchgeführt und damit ihre „Meisterprüfung“ abgelegt. Das Gebäude V3 wurde letztlich mit A bewertet – ein gutes Ergebnis angesichts eines schon vier Jahre alten Zu den Besonderheiten des Büro- und Entwicklungsge- Bestandsgebäudes. In Zukunft sind Effizienzgewinne bäudes zählt, dass durch die Anbindung an das firmen- beispielsweise möglich, indem die eu.bac-Schlüsselin- eigene Nahwärmenetz keine eigene Heizung vorhanden dikatoren (KPI) für einzelne Anlagenteile eingesetzt oder ist. Dafür arbeitet in einem Nachbargebäude eine Ver- Wetterprognosen zur Betriebsoptimierung einbezogen bundanlage aus Gaskessel und Erdwärmepumpe, die in werden. einen Verteiler mit Zortström-Technologie einspeist, der die weitere Versorgung der angeschlossenen Teilnehmer Für WAGO bildet die Bewertung eine sehr gute und be- übernimmt. Lüftungsseitig ist eine Zentralanlage mit triebswirtschaftlich belastbare Grundlage, um Investi- Wärmerückgewinnung installiert. tionen in die Gebäudeeffizienz zu kalkulieren. „Weil wir systematisch vergleichen, kommen wir verlässlich zu Er- Das Gebäude ist mit Gebäudeautomatisierung und gebnissen die zeigen, wo sich Modernisierungen im Ge- Zählwerterfassung ausgestattet, die Rückmeldung über bäudebestand tatsächlich lohnen“, erklärt Auditor Martin die Betriebszustände geben. Tageslichtabhängige Be- Hardenfels, gleichzeitig Leiter Projektvertrieb bei WAGO. leuchtung, automatischer Sonnenschutz und die Raum- temperierung werden flexibel und nach Bedarf geführt. Die Anwendung der systematischen eu.bac-Bewertung Zur Raumautomatisierung wird WAGO-flexROOM® eigener Gebäude bietet dem Unternehmen ein sehr gutes eingesetzt, das die drei Gewerke in einem Gerät zu- Testfeld, um Verfahren auszuprobieren und zu definie- sammenfasst. Die Beleuchtung ist mit DALI realisiert: ren. Der Vorteil für Kunden besteht vor allem darin, dass Multisensoren an den Arbeitsplätzen erfassen die Be- WAGO auch künftig Produkte mit den jeweils aktuellen leuchtungsstärke und die Anwesenheit. Effizienzansprüchen entwickelt. Hierbei handelt es sich nach Auskunft von Martin Hardenfels vor allem um Soft- Die Raumtemperatur wird durch Heizkörper und Kühl- ware-Funktionen, die es ermöglicht mit möglichst gerin- register vor den Luftauslässen mit elektrischen Ventilen gem Aufwand effiziente Funktionen zu realisieren und die realisiert. Alle weiteren Sensoren sind über EnOcean- die Basis für einen effizienten Betrieb zu legen. Funk mit der Einzelraumregelung verbunden. Laut Ener- gieausweis hat das Gebäude einen Bedarf, der unter dem EnEV-Anforderungswert liegt. Doch wie effizient ist die eingesetzte Technik? Bei der Analyse entsprechend der eu.bac-Systematik wurde deutlich, dass die Lüftungsanlage die meisten Ab- züge in der Bewertung mit sich bringt, weil das Gebäude zum Teil mit einem konstanten Volumenstrom versorgt wird. In diesem Fall lässt sich eine Nachrüstung jedoch Das Bestandsgebäude V3 der WAGO-Zentrale in Minden. Frischgebackene Auditoren des Unternehmens haben das Büro- und Entwicklungsgebäude analysiert und mit A bewertet. Insight 3.2015 19
© Michael Ehrhart Around 18,100 students study at Saarland University in Saarbrücken and Homburg. An der Universität des Saarlandes in Saarbrücken und Homburg gibt es rund 18.100 Studierende. Best practice Saarland University to become a Model Energy Campus As part of the EULE project, Saarland University Targeted energy savings of 30% (SU) is currently optimising its operation and de- veloping into a model energy campus. The goal of The university administration wants to reduce the cam- the project is to perform a range of inspections pus’ energy consumption by around 30%. The project and measures to achieve energy savings of around consortium has created special methods and tools to 30% by 2017. minimise energy consumption and case studies are now being used to develop them further. It is hoped that ulti- A consortium of engineers, business economists and mately, a common theoretical model is created for opti- psychologists are currently working on the project “SU mised energy use in the public buildings. model energy campus: optimised energy consumption throughout the premises” – or EULE for short. SAUTER is playing an important role for the building automation focus of the project. The campus buildings of the SU in Saarbrücken were constructed over different generations. Particularly in the older, badly insulated buildings, the electricity and district heating costs were relatively high. This being one of the reasons why the German Ministry for Economic Affairs and Technology is sponsoring the EULE project. 20 Insight 3.2015
SAUTER was commissioned to refurbish selected cam- Prediction model is trend-setting pus buildings. This included upgrading the building’s au- tomation system and connecting buildings to the SAUTER The next step is to integrate the findings of economists Energy Management Solution (EMS). Where buildings and environmental psychologists involved in the project were technically obsolete, the necessary additional auto- into the already developed model which predicts energy mation components were fitted. The new automation was consumption. This will create a shared flexible and con- now in place on campus and the needed case studies figurable tool, enabling the effect of various measures to could be performed. be forecast. Other universities are set to apply this model. The scientific values and knowledge gained from this joint During the EULE project, SAUTER installed devices in- work provide a great springboard to carry out more refur- cluding ecos 5 room controllers and programmable bishment projects – and in the private sector too. ecoUnit operating devices. Heating, energy and water consumption is also being monitored in three selected Michael Sieb buildings. The data generated by these facilities is col- Planung und Vertrieb Systems lected in SAUTER’s EMS system. It is then used to sys- SAUTER Deutschland, Sauter-Cumulus GmbH tematically compare energy consumption under varying michael.sieb@de.sauter-bc.com conditions. A monitoring system was especially devel- www.sauter-cumulus.de oped that documented in detail the energy savings. The building automation work also involved SAUTER upgrading all heating installations. This will bring about improvements in the heating curves and switching pro- grammes for night and weekend set-back modes. It also enables the heating to be switched off completely during summer. Thus the cooling systems function was examined and the ventilation system’s operating times, volume flow and pressure loss, etc. were also inspected and adjusted and depending upon usage, buttons or presence detec- tors were added for switching the systems on and off. Via M-Bus, SAUTER consolidated all the energy readings from the big, energy-intensive ventilation and cooling systems in the building management system. Flow rates can therefore be captured, together with consumption values, in specified time steps. The campus buildings of the SU in Saarbrücken Die Gebäude auf dem Campus der UdS in Saarbrücken were constructed over different generations and the stammen aus ganz unterschiedlichen Baujahren und standards of air conditioning are quite different. weisen unterschiedliche klimatechnische Standards auf.
You can also read