Your Inspirations. Our Innovations. UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting Your Data CATALOGUE 2014 Revision 2.0
Table of Contents Table of Contents About Us - Company Profile 02 Online UPS 04 Professional Series (1P/1P) - Tower 04 Professional Series (1P/1P) - Dual 06 Master Series (1P/1P) - Tower 08 Master Series (1P/1P) - Combo 12 Master Series (1P/1P) - 2-in-1 Rack/ Tower 14 Master Series (3P/1P) - Tower 18 Master Series (3P/1P) - Rack Mount 21 Master Series (3P/3P) - Tower 23 Power Series 25 PPM Series 30 Line Interactive UPS 33 PRO SFC Series 33 PRO SFT Series 35 PRO Series 37 PRO-L Series 39 PRO Rack/ Tower Series 41 Outdoor Line Interactive Series 43 Inverter UPS 45 LCD Inverter Series 45 Auto Voltage Regulator 47 PVR Series 47 DC UPS 48 PDC Series 48 PBU Series 49 Solar UPS 50 Zonne Series 51 PPS Series 52 PCC Series 53 PSI Hybrid Series 54 PSI On-Grid Amnets Series 55 PSI Off-Grid Haus Series 56 PSI Off-Grid Haus MPPT Series 57 Software & Accessories 59 Appendix 64 01
About Us - Company Profile Fida International (S) Pte Ltd has been a provider of technologically innovative and user-friendly products manufactured under the brand name “PROLiNK®” since 1991. With more than two decades of professional experience in the information communications sector, PROLiNK is now renowned as a specialist in its field, especially in the area of Back-up UPS products. Over the years, PROLiNK has built its presence through a strong foundation of technological leadership within the South Asian, South-east Asian and Middle Eastern regions and is continuing to build its presence worldwide. With its current network of sales offices in more than 20 countries, customers can be assured that PROLiNK is able to provide the right solutions to meet the needs of both home and business users within each geographical location both efficiently and effectively. The company’s quest for continuous improvement and quality assurance to its customers has earned us the ISO9001 quality certification since 1999. With its consistently strong commitment to quality, customers can be assured of they are getting true value - superior quality products at affordable prices. Our Mission Accentuate The Best For The E-generation PROLiNK® aspires to accentuate the best for the e-generation. With technology becoming an essential aspect of modern living, the e-generation concept has gradually become ingrained in our lives and digital literacy is becoming more and more commonplace. PROLiNK products are designed to make technology work for the e-generation. Created with the end-user in mind, our products are crafted to enhance performance whether you are at work or play – our products work harder, while you work smarter to achieve your desired results with less effort and better efficiency. Providing value to our consumers – whether home or business users, remains a firm commitment of PROLiNK. With its wide range of quality products, PROLiNK makes it easy for home users to find user-friendly yet affordable solutions for their technological needs, while business users are assured of reliable and secure solutions for their network infrastructure. Our Vision Ideas, Innovation and Information PROLiNK® aims to be the key driving force behind technological changes and improvements in both developing and developed countries. With its strong focus on technology, our team sets high standards for itself in the areas of innovation, change and improvement so as to provide the next generation of users with products that are suita- ble for their technology advanced environments. The small “i” in PROLiNK represents ideas, innovation and information – three key pillars of growth that drive us towards achieving excellence in our field of expertise and challenges us to think beyond our usual boundaries. 02
About Us - Company Profile Core Values Secured Information Management With more than two decades of professional experience in providing backup power solutions to our customers, we are able to support our customers with superior technological know-how and expertise, as well as advice on market trends. At the same time, we are also fully committed to protecting the privacy of our customers and to manage confidential information discreetly. Innovative Design Our products are carefully thought out to ensure that each item is designed to meet the needs of our customers. With the team’s solid experience in the UPS market, customers can be certain that our designs are innovative yet functional, and suitable for each dynamic market that we have a presence in. Superior Service Standards Strict and rigorous testing makes up a huge part of our quality control procedures. We ensure that every item meets our strict standards – from the individual components to the actual finished product. Total Quality Assurance System Our products go through careful planning and checks at every stage of the production cycle - from the beginning stages of product design to the manufacturing and finally the actual delivery of the goods. This guarantees that our customers receive only the best quality goods – of high reliability and durability. Our total quality system has been audited and approved by globally recognized bodies. Range of UPS The wide range of our products gives you an infinite range of solutions: 1. Online UPS 2. Line Interactive UPS 3. Inverter UPS 4. DC UPS 4. Solar UPS 03
Online UPS Professional Series (1P/1P) - Tower Online Professional Series 1kVA – 6kVA Small Computer Local Area Work-Stations Servers Network Network (LAN) Professional Series (1P/1P) is an advanced yet affordable single-phase UPS system that uses on-line double conversion technology. It is designed to protect against power outages, disturbances and spikes, making them most suitable for voltage fluctuating environments. This device is able to provide high-efficiency charging with its high input power factor correction. Professional Series is available in capacities ranging from 1000VA to 6000VA. High voltage battery chargers and battery extension assembly are made available for longer runtime applications. Users can also have the option to top-up an additional isolation transformer to obtain pure and clean power for their sensitive devices. • True Double-Conversion Online UPS • Wide input voltage range (110~300VAC) • Input Power Factor correction of 0.98 • Output Power Factor of 0.80 • Generator compatible • LCD User Interface • Choice between RS-232 communication port or USB / RS-232 / AS400 / SNMP interface • Smart battery charger designed to optimize battery performance • Isolation transformer (optional) Rear Panel For 1kVA to 6kVA model 1. Output receptacles 5 5 2. AC input 4 4 3. Input circuit breaker 6 6 5 6 8 8 4. Network/Fax Modem Surge Protection 9 9 5. Intelligent slot for communication port/ 1 1 SNMP. (standard come with USB port) 9 6. External battery connection (only available for L model) 4 1 3 7. Output terminal 3 7 2 7 8. Output circuit breaker 2 2 9. Fan PRO901S/L PRO903S/L PRO906S/L PRO902S/L 04
Online UPS Options • RS-232 Port (communication interface). • AS-400 Card (External alarm indicator). • SNMP Card for data communication via network connection. • Output Isolation Transformer. • External PDU & Maintenance Bypass Switch. (suitable for UPS up to 3kVA only) Full Specifications MODELS PRO901S/ L PRO902S/ L PRO903S/ L PRO906S/ L Capacity 1000 VA 2000 VA 3000 VA 6000 VA INPUT Nominal Voltage 200/208/220/230/240 VAC Voltage Range 110-300 VAC ± 5 % at 50% / 160-300 VAC ± 5 % at 100% Nominal Frequency 50 or 60Hz Frequency Range 40 ~ 70Hz Power Factor ≧ 0.98 OUTPUT Output Voltage 200/ 208/ 220/ 230/ 240VAC Static Regulation ±1% ±3% Frequency 50Hz or 60Hz auto selection Frequency Range 47 ~ 53 Hz or 57 ~ 63 Hz Power Factor 0.8 Current Crest Ratio 3:1 Liner Load ≦ 3 % THD Voltage Distortion Non-Liner Load ≦ 7 % THD Waveform Pure Sinewave EFFICIENCY AC Mode Up to 88% BATTERY Type Valve regulated Lead Acid battery (Maintenance free batteries) Capacity 9AH 10AH Standard Model Recharge Time (Typical) 9 hours recover to 90% capacity Charging Current 1.0 A (max) Type Depending on the application Long-Run Model Capacity Depending on the application Charging Current 1A / 2A / 4A / 8A (Default) 1A / 2A / 4A / 6A (Default) OVERLOAD 100% < Load < 110% Overload warning only (No shutdown) 110% < Load 130% 1.5 seconds INDICATORS LCD Display Input / Output Voltage, Load Level, Batt Level, UPS Status, Fault Conditions PHYSICAL Dimension (mm) D x W × H 397 x 145 x 220 421 × 190 × 318 426 × 190 × 318 Standard Model Net Weight (kgs) 10.8 17.2 28.7 36.2 Dimension (mm) D × W × H 397×145×220 421×190×318 426×190×318 Long-Run Model Net Weight (kgs) 5.7 8.9 13.1 15.2 ENVIRONMENT Operation Humidity
Online UPS Professional Series (1P/1P) - Dual Online Professional Series 1kVA – 3kVA Small Computer Local Area Work-Stations Servers Network Network (LAN) Professional Series (1P/1P) - Dual is an advanced yet affordable single-phase UPS system that uses on-line double conversion technology with 2 different input voltage ranges. It is designed to protect against power outages, disturbances and spikes, making them most suitable for voltage fluctuating environments. Professional Series (1P/1P) – Dual is most suitable to be used in areas that are plagued by voltages that are as low as 100V. With the advanced double-conversion technology, the dual series is able to regulate and maintain consistent output even when it is fully loaded. Also, this device is able to provide full isolation and complete common mode noise rejection from complementary equipment. The Dual Series is available in various capacities, ranging from 1000VA to 3000VA. • Online True double-conversion • Accepts Ultra Low Voltage inputs for special power environment • Wide input voltage range (88-144VAC and 176-288VAC) at full load • Input Power factor correction of 0.99 • Output Power Factor of 0.80 • LCD User Interface • Complete galvanic isolation design offers full isolation and complete common mode noise rejection • Choice between RS-232 communication port or USB / RS-232 / AS400 / SNMP interface Rear Panel 5 5 For 1kVA to 3kVA model 4 4 1. Output receptacles 5 6 9 6 9 6 2. AC input 8 3. Input circuit breaker 9 1 1 4. Network/Fax/Modem surge protection 9 9 5. Intelligent slot for communication port/SNMP 4 1 3 2 2 7 (standard come with USB port) 2 6. External battery terminal (only available for Long-run model) 9 9 9 7. Output terminal 8. Output circuit breaker 9. Fan PRO901D S/L PRO902D S/L PRO903D S/L 06
Online UPS Options • RS-232 Port (communication interface) • AS-400 Card (External alarm indicator) • SNMP Card for data communication via network connection. • External PDU & Maintenance Bypass Switch. (suitable for UPS up to 3kVA only) Full Specifications MODELS PRO901D S/L PRO902D S/L PRO903D S/L Capacity 1000 VA 2000 VA 3000 VA INPUT Nominal Voltage 208/ 220/ 230/ 240VAC Voltage Range 88VAC ~ 144VAC and 176VAC ~ 288VAC (auto sensing) Nominal Frequency 50 or 60Hz Frequency Range 45 ~ 65Hz Power Factor ≧ 0.99 OUTPUT Output Voltage 208/ 220/ 230/ 240VAC Static Regulation ±1% Frequency 50Hz or 60Hz auto selection or selectable Frequency Range 47 ~ 53 Hz or 57 ~ 63 Hz Power Factor 0.8 Current Crest Ratio 3:1 Linear Load ≦ 2% THD Voltage Distortion Non-Linear Load ≦ 6% THD Waveform Pure Sinewave EFFICIENCY AC Mode Up to 80% BATTERY Type Valve regulated Lead Acid battery (Maintenance free batteries) Capacity 9AH Standard Model Recharge Time (Typical) 5 hours recover to 90% capacity Charging Current 1.0 A (max) Type Depending on the application Long-Run Model Capacity Depending on the application Charging Current 4.0 A or 8.0 A (max.) OVERLOAD 100% < Load < 110% Overload warning only (No shutdown) 110% < Load < 130% 30 seconds >130% 1.5 seconds INDICATORS LCD Display Input/ Output Voltage, Load Level, Batt Level, UPS Status, Fault Conditions PHYSICAL Dimension (mm) D x W × H 423 x 145 x 320 426 x 190 x 448 Standard Model Net Weight (kgs) 26.5 34 56 Dimension (mm) D × W × H 423 x 145 x 332 421 x 190 x 448 Long-Run Model Net Weight (kgs) 21.5 23 41 ENVIRONMENT Operation Humidity
Online UPS Master Series (1P/1P) - Tower Online Master Series 1kVA – 10kVA Small Computer Local Area Work-Stations Servers Network Network (LAN) Master Series (1P/1P) is a single-phase UPS system that employs a true online double-conversion technology. It is designed to deliver clean and high quality electrical power for devices such as small computer centres, servers, telecom applications, lab testing equipments and industrial applications. The Master series (1P/1P) comes with a wide input voltage range that protects devices against outages, disturbances and spikes. In addition, this device comes with a smart battery charger that optimizes the battery performance, ensuring longer lasting battery life. High voltage battery chargers and battery extension assembly are made available for longer runtime applications. The Master series (1P/1P) also comes in various capacities ranging from 1kVA to 10kVA to suit your needs. The 6kVA and 10kVA UPS system comes with 2 additional features; an internal bypass system and a parallel redundant system. An internal bypass system allowing continuous power is integrated for convenience when maintenance is necessary and a parallel redundant system that allows two UPS models to operate in parallel as backup for each other. • True Double-Conversion Online UPS • Wide input voltage range (110~300VAC) • Input Power Factor correction of 0.99 • Output Power Factor 0.80 • Generator compatible • LCD User Interface • Choice between RS-232 communication port or USB / RS-232 / AS400 / SNMP interface • Smart battery charger designed to optimize battery performance Rear Panel For 1kVA to 3kVA model 1. Programmable outlets: connect to non-critical loads 7 8 9 7 8 9 2. Output receptacles: connect to mission critical loads 7 8 9 6 6 3. AC input 5 5 6 4. Input circuit breaker 13 10 13 10 5 10 5. Network/ Fax/ Modem surge protection 12 6. Emergency power off function connector (EPO) 13 7. USB communication port 1 13 13 2 1 8. RS-232 communication port 4 2 1 4 2 4 9. SNMP intelligent slot 11 3 3 3 10. External battery connection (only available for L model) 11. Output terminal PRO801S/L PRO802S/L PRO803S/L 12. Output circuit breaker PRO8015S/L 13. Fan 08
Online UPS For 6kVA to 10kVA model 1. RS-232 communication port 1 2 3 4 5 5 6 2. USB communication port 3. Emergency power off function connector (EPO connector) 8 7 4. Share current port (only available for parallel model) 5. Parallel port (only available for parallel model) 6. Intelligent slot 8 14 7. Charger fan 8. Power stage fan 9. Maintenance bypass switch 9 10. Input circuit breaker 10 11. Input/Output terminal 12. Output terminal 1 16 12 13 15 11 13. Output terminal 2 14. External battery terminal (only available for Long-run model) 15. Utility input terminal 16. Output IEC Socket PRO806S/L PRO810S/L Battery Pack For 1kVA to 3kVA model Model G6 G12 G18 Battery Type 12V7AH 12V9AH 12V7AH 12V9AH 12V7AH 12V9AH Battery Number (max) 6 pcs 6 pcs 12 pcs 12 pcs 18 pcs 18 pcs Dimension (DxWxH) mm 397 × 145 × 220 421 × 190 × 318 535 × 190 × 318 Weight (kg) 18 20 36 40 55 61 For 6kVA to 10kVA model Model G40 G60 Battery Type 12V7AH 12V9AH 12V7AH / 12V90AH Battery Number (max) 40 pcs 40 pcs 60 pcs 60 pcs Dimension (DxWxH) mm 592 × 250 × 576 830 × 250 × 576 Weight (kg) 109 125 166 190 09
Online UPS Options • AS-400 Card (External alarm indicator) • SNMP Card for data communication via network connection. • Output Isolation Transformer. • External PDU & Maintenance Bypass Switch. (Only suitable for UPS that are up to 3kVA) Full Specifications MODELS PRO801S/ L PRO8015S/ L PRO802S/ L PRO803S/ L PRO806S/ L PRO810S/ L Capacity 1000 VA 1500 VA 2000 VA 3000 VA 6000 VA 10000 VA INPUT Nominal Voltage 200/208/220/230/240 VAC Voltage Range 110 - 300 VAC ± 5 % at 50% load / 160 - 300 VAC ± 5 % at 100% load Nominal Frequency 50 or 60Hz Frequency Range 40 ~ 70Hz Power Factor ≧ 0.99 OUTPUT Output Voltage 200/ 208/ 220/ 230/ 240VAC Static Regulation ±1% Frequency 50Hz or 60Hz auto selection or selectable Frequency Range 47 ~ 53Hz or 57 ~ 63Hz Power Factor 0.8 Current Crest Ratio 3:1 Linear Load ≦ 2% THD ≦ 3% THD Voltage Distortion Non-Linear Load ≦ 4% THD ≦ 6% THD Waveform Pure Sinewave EFFICIENCY AC Mode Up to 90% BATTERY Type Valve regulated Lead Acid battery (Maintenance free batteries) Capacity 7AH 9AH 7AH 9AH 7AH 9AH Standard Model Recharge Time (Typical) 9 hours recover to 90% capacity Charging Current 1.0 A (max) Type Depending on the application Long-Run Model Capacity Depending on the application Charging Current 8.0 A (max) 4.0 A (max) OVERLOAD 100% < Load < 110% Overload warning only (No shutdown) 110% < Load < 130% 30 seconds >130% 2 seconds INDICATORS LCD Display Input/ Output Voltage, Load Level, Batt Level, UPS Status, Fault Conditions PHYSICAL Dimension (mm) D x W × H 397 x 145 x 220 421 × 190 × 318 592 x 250 x 576 Standard Model Net Weight (kgs) 13 14 26 28 81 83 Dimension (mm) D × W × H 397×145×220 421×190×318 592 x 250 x 576 Long-Run Model Net Weight (kgs) 7 7 13 13 25 27 ENVIRONMENT Operation Humidity
Online UPS True double-conversion Online UPS SNMP + USB + RS-232 Multiple A true double conversion UPS will provide clean, high Communication port for Models ranging from 1 level quality power to fully protect mission-critical to 3kVA. devices such as sensitive networks, small computer This feature allows either the USB or RS-232 centers, servers, telecom applications, as well as for communication port to simultaneously operate with the industrial applications. SNMP interface. Output Power factor of 0.8 Higher Accuracy for Output Voltage As compared to the online UPS models in the current The advanced control firmware allows the Master Series market, the Master Series (1P/1P) provides better output (1P/1P) to achieve higher accuracy with the output power factor of up to 0.8. This unit is able to offer higher voltage tolerance of +/- 1%. The device is applicable for performance and efficiency for your critical applications. the use with critical test and IT equipments. Smart Battery Charger Design to Optimise Wide Input Voltage Range (110 V -300 V) Battery Performance Master Series (1P/1P) can still provide stable power to Master Series (1P/1P) 1-3kVA models are equipped with connected devices under unstable power environments. a 2-stage charger design to guarantee precise battery discharge time. The charging voltage is also automatically adjusted according to the ambient Programmable Power Management Outlets temperature, to lengthen the service life of the battery. The programmable power management outlets allow users to The 6kVA and 10kVA models come with an additional easily and independently control the extendable charger that allows for large-capacity battery load segment. In the event of a charging. power failure, this feature enables users to manage and extend the battery time for mission critical DSP Technology (Applies for the above devices by shutting down the models) non-critical devices. A DSP controller improves the performance and Programmable Outlets (P1) efficiency of the UPS. - connect to non-critical devices Maintenance Bypass Available For 6kVA And 50/60 Hz Frequency Converter Mode Above Models Lock output frequency at 50Hz or 60Hz to suit power Internal bypass assures continuous power to critical sensitive equipments. devices during UPS maintenance. ECO Mode Operation For Energy Saving Optional Hot Standby and N+X Parallel Offers efficiency as high as 97% to cut energy usage & Redundant System (Available for Models cost. UPS power application via static bypass, timely ranging from 6kVA and above) returning to online double conversion when the need arises. An internal bypass system allowing continuous power is integrated for convenience when maintenance is necessary and a parallel redundant system that allows Emergency Power Off (EPO) Function two UPS models to operate in parallel as backup for each other. This feature can protect the personnel and the equipment in the case of fire outbreak or other types of emergency. 11
Online UPS Master Series (1P/1P) - Combo Online Master Series 6kVA – 10kVA Small Computer Local Area Work-Stations Servers Network Network (LAN) Master Series (1P/1P) - Combo is a single-phase UPS system that employs a true online double-conversion technology. It is designed to deliver clean and high quality electrical power for devices such as small computer centres, servers, telecom applications and industrial applications. Designed with a small footprint, this device ensures that it will fit into any corner of your small office. Master Series (1P/1P) - Combo series comes with a wide input voltage range that protects devices against the outages, disturbances and spikes. Fitted with a smart battery charger design, this device is able to optimize its battery performance, ensuring longer lasting battery life. High voltage battery chargers and battery extension assembly are made available for longer runtime applications. The Combo series are available in the following capacities; 6kVA and 10kVA. • True double-conversion on line UPS • DSP technology guarantees high performance • Wide input voltage range (110-300 VAC) • Active input power factor correction of 0.99 • Output power factor of 0.8 • 50Hz/60Hz frequency converter mode • Standard backup UPS and long backup UPS in one integrated unit • Charging current can be adjusted via LCD or software (1A~6A) • Emergency power off function (EPO) • Comes with a USB and PS-232 communication port • Comes with a mini slot for AS-400 / SNMP communication card • Comes with a maintenance bypass function 4 Rear Panel 1 2 3 For 6kVA to 10kVA model 5 1. RS-232 communication port 7 6 2. USB communication port 3. Emergency power off function connector (EPO connector) 8 4. Intelligent slot 4 5. Power stage fan 9 1 2 3 6. Maintenance bypass switch 7. Input circuit breaker 5 10 8. Input/Output terminal 7 9. External battery terminal (only available for Long-run model) 6 10. Battery Compartment (only available for Standard model) 8 PRO806CL/ PRO806C/ PRO810CL PRO810C 12
Online UPS Options • AS-400 Card (External alarm indicator) • SNMP Card for data communication via network connection. • Output Isolation Transformer. Full Specifications MODELS PRO806C/ CL PRO810C/ CL Capacity 6000 VA 10000 VA INPUT Nominal Voltage 208/ 220/ 230/ 240VAC Voltage Range 110-300 VAC at 50% load / 176-300 VAC at 100% load Nominal Frequency 50 or 60Hz Frequency Range 46 ~ 64Hz Power Factor ≧ 0.99 OUTPUT Output Voltage 208/ 220/ 230/ 240VAC Static Regulation ±1% Frequency 50Hz or 60Hz auto selection or selectable Frequency Range 46 ~ 54Hz or 56 ~ 64Hz Power Factor 0.8 Current Crest Ratio 3:1 Linear Load ≦3 % THD Voltage Distortion Non-Linear Load ≦ 6% THD Waveform Pure Sinewave EFFICIENCY AC Mode Up to 90% BATTERY Type Valve regulated Lead Acid battery (Maintenance free batteries) Capacity 7AH 9AH Standard Model Recharge Time (Typical) 9 hours recover to 90% capacity Charging Current 2.0A Type Depending on the application Long-Run Model Capacity Depending on the application Charging Current 6.0 A (max) OVERLOAD 100% < Load < 110% 10 minutes 110% < Load < 130% 1 minute >130% 1 second INDICATORS LCD Display Input/ Output Voltage, Load Level, Batt Level, UPS Status, Fault Conditions PHYSICAL Dimension (mm) D x W × H 360 x 192 x 688 440 x 192 x 688 Standard Model Net Weight (kgs) 60 75 Dimension (mm) D × W × H 360 x 192 x 318 440 x 192 x 318 Long-Run Model Net Weight (kgs) 21 23 ENVIRONMENT Operation Humidity
Online UPS Master Series (1P/1P) - 2-in-1 Rack/ Tower Online Master Series 1kVA – 10kVA Small Computer Local Area Work-Stations Servers 19” Rack Network Network (LAN) Mount Master Series (1P/1P) – 2-in-1 Rack/Tower is a single-phase UPS system that employs a true online double-conversion technology. This device comes with a practical 2U universal-mount case that provides an option for the user to either install it as a floor-standing tower or in a mounted position using a 19-inch rack mount bracket. With its high density output power factor of 0.9, this device is able to provide outstanding performance and efficiency to meet the requirements of a mission critical environment. This 2-in-1 Rank/Tower UPS is brilliantly designed with a hot-swapping battery feature to facilitate the replacement of the existing batteries without the hassle of having to shut the devices down. On top of that, models with a 6kVA and 10kVA capacity comes with a parallel redundant system that allows two UPS models to operate in parallel and as backup for each other. High voltage battery chargers and battery extension assembly are made available for longer runtime applications. The PROLiNK 2-in-1 Rank/Tower UPS comes with a wide range of capacities from as low as 1kVA to as high as 10kVA to accommodate to your every need. • True Double-Conversion Online UPS • Rack or Tower design • Wide input voltage range (110~300VAC) • Input Power Factor correction of 0.99 • Output Power factor of 0.90 • 50/60Hz frequency converter mode • Hot-Swappable battery design • Emergency Power Off (EPO) function • ECO Operation Mode provides energy conservation • Generator Compatible • Option available for long-run models to expand the charger capacity to 8A • Multiple communication interface (SNMP/USB/RS-232) • Smart battery charger is designed to optimize overall battery performance • Selectable output voltage via LCD panel 14
Online UPS Rear Panel For 1kVA to 3kVA model 1. Programmable outlets: Connect to non-critical loads 1 2. Output receptacles: Connect to mission-critical loads 7 3 3. AC input 5 12 6 10 9 8 4. Input circuit breaker 2 4 5. Network/Fax/Modem surge protection PRO801RS/RL PRO8015RS/RL PRO802RS/RL 6. Emergency power off function connector (EPO) 7 1 3 7. USB communication port 5 12 12 10 9 6 11 8. RS-232 communication port 8 9. SNMP intelligent slot 2 4 10. External battery terminal (only available for Long-run model) PRO803RS/RL 11. Output IEC320-C20 connector 12. Fan For 6kVA to 10kVA model 1. Programmable outlets: Connect to non-critical loads 2. Output receptacles: Connect to mission-critical loads 3. AC input 4. Input circuit breaker 5. Network/Fax/Modem surge protection 13 6. Emergency power off function connector (EPO) 9 6 7. USB communication port 4 7 12 8. RS-232 communication port 11 16 15 14 10 9. SNMP intelligent slot 7 10. Battery connection PRO806RS/RL 11. Input terminal PRO810RS/RL 12. Fan 13. Parallel port (only available for parallel model) 14. External maintenance by-pass switch connection 15. Output Terminal 16. Ground Battery Pack For 1kVA to 10kVA model Model G8R G12R G20R Battery Type 12V9AH 12V7AH 12V9AH Battery Number (max) 8 pcs 12 pcs 20 pcs Dimension (DxWxH) mm 480 × 438 × 88 600 × 438 × 88 580 × 438 × 133 Weight (kg) 29.8 42.5 57 63 15
Online UPS Options • AS-400 Card (External alarm indicator) • SNMP Card for data communication via network connection • MODBUS Card (communication interface) • Universal Rackmount Slider for installation in rack cabinets • External PDU & Maintenance Bypass Switch (Only suitable for UPS that are up to 3kVA) • Maintenance Bypass Switch [MBS] (Only available in UPS ranging from 6 to 10kVA) • External Automatic Transfer Switch (ATS) Full Specifications MODELS PRO801RS/ RL PRO8015RS/ RL PRO802RS/ RL PRO803RS/ RL PRO806RS/ RL PRO810RS/ RL Capacity 1000 VA 1500 VA 2000 VA 3000 VA 6000 VA 10000 VA INPUT Nominal Voltage 200/ 208/ 220/ 230/ 240 VAC Voltage Range 110-300 VAC at 50% load / 160-300 VAC at 100% load Nominal Frequency 50 or 60Hz Frequency Range 40 ~ 70Hz Power Factor ≧ 0.99 OUTPUT Output Voltage 200/ 208/ 220/ 230/ 240VAC Static Regulation ±1% Frequency 50Hz or 60Hz auto selection or selectable Frequency Range 47 ~ 53Hz or 57 ~ 63Hz Power Factor 0.9 Current Crest Ratio 5:1 5:1 3:1 Linear Load ≦ 2% THD Voltage Distortion Non-Linear Load ≦ 4 % THD Waveform Pure Sinewave EFFICIENCY AC Mode Up to 90% BATTERY Type Valve regulated Lead Acid battery (Maintenance free batteries) Capacity 9AH 7AH 9AH Standard Model Recharge Time (Typical) 4 hours recover to 90% capacity 9 hours recover to 90% capacity Charging Current 1.0 A (max) Type Depending on the application Long-Run Model Capacity Depending on the application Charging Current 1A / 2A / 4A / 8A 4.0 A (max) OVERLOAD 100% < Load < 110% Overload warning only (No shutdown) 10 minutes 110% < Load < 130% 30 seconds 1 minute >130% 2 seconds 1 second INDICATORS LCD Display Input/ Output Voltage, Load Level, Batt Level, UPS Status, Fault Conditions PHYSICAL UPS Unit: UPS Unit: 580x438x133 (3U) 688x438x133 (3U) Dimension (mm) D x W × H 380x438x88 (2U) 480x438x88 (2U) 600x438x88 (2U) Standard Model Battery Unit: Battery Unit: 580x438x133 (3U) 580x438x133 (3U) UPS unit: 20 UPS unit: 23.5 Net Weight (kgs) 12.9 17.6 20.6 28 Battery pack: 57 Battery pack: 63 Dimension (mm) D × W × H 380x438x88 (2U) 480x438x88 (2U) 600x43x88(2U) 580x438x133 (3U) 668x438x133 (3U) Long-Run Model Net Weight (kgs) 8.6 10.7 11.3 13.8 20 23.5 ENVIRONMENT Operation Humidity < 95 % non-condensing Ambient Temperature 0°C - +40°C Noise Level < 60dBA @ 1 Mete Regulations Safety: EN62040-1-1; EMI: EN62040-2; EN62040-3 MANAGEMENT USB/ RS-232 Supports Windows® 2000/2003/XP/Vista/2008/7, Linux, Unix, and MAC L stands for Long-run model S stands for Standard model *All specifications, designs and contents are subject to change without prior notice. 16
Online UPS True Double-conversion Online UPS Output power factor 0.9 A true double conversion UPS system will provide clean Master (1P/1P) 2-in-1 rack/Tower Series is a and high quality electrical power to fully protect mission high-density UPS system with an output power factor of critical systems such as sensitive networks, small 0.9. With this high power factor, the Master series is able computer centers, servers, telecom applications and to provide higher performance to critical applications. industrial applications. Programmable Power Management Outlets User-friendly LCD Display The programmable power management outlets allow The front panel digital display comes with an auto- users to easily and independently control the load rotation feature that caters to your installation segment. In the event of a power failure, this feature preference; either vertically or wall mounted. enables users to manage and extend the battery time for mission critical devices by shutting down the non-critical devices. Programmable Outlets (P1) - connect to non-critical devices Rack Display Tower Display ECO and Advanced ECO Mode for Energy Saving Rack / Tower Design It allows the UPS to operate in high efficiency of up to This device comes with a practical 2U universal-mount 97% during energy saving ECO mode and 98% in case that provides an option for the user to either install operation mode. In the event of an electrical AC failure, it as a floor-standing tower or in a mounting position the inverter will automatically step-in and provide using a 19-inch rack mount bracket. electrical supply to the connected systems. Emergency Power Off Function (EPO) This feature provides adequate protection for the user and the equipment against hazards such as fire break-out or other emergencies. 19” Rack-mounting Floor-standing Tower Hot-swapping Battery Design The hot-swapping battery feature helps to facilitate the replacement of the existing batteries without the hassle High Output Crest Ratio of having to shut the devices down. The Master (1P/1P) 2-in-1 Rack/Tower Series is designed with a high output crest ratio of 5:1 that allows the device to be extremely compatible with equipment such as compressors, generators and motors. Output Voltage Regulation (tolerance +/- 1%) The Master (1P/1P) 2-in-1 rack / Tower Series is able to Long Battery Runtime Models Available produce extremely stable and clean electrical power with Our Long Battery Runtime Models offers the flexibility to its high efficiency output voltage regulator. This regulator add-on additional external batteries to provide a longer is able to achieve a tolerance of +/- 1%, making it back-up time. extremely compatible even with sensitive power supplies. 17
Online UPS Master Series (3P/1P) - Tower Online Master Series 10kVA – 30kVA Local Area Telecommunication Data Electro-Medical Storage Emergency E-Business Network Devices Centre Device PLCS Alarm (Server Farms, (LAN) Devices ISP/ASP/POP) Master Series (3P/1P) three-phase input / single-phase output, true online double conversion UPS system guarantees consistent and quality electrical power to protect your mission critical applications such as mid-sized business servers, telecommunication systems and industrial equipment. The (3P/1P) UPS is designed with a wide input voltage range to handle voltage fluctuating situations and a high accuracy output voltage to fail-safe your equipment. This Voltage Frequency Independent (VFI) system is available in capacities from 10kVA to 30kVA. By adopting the latest IGBT technology, this device is able offer excellent voltage switching characteristics during generator operation. An internal bypass system allowing continuous power is also integrated for convenience when maintenance is necessary. In addition, this device comes with a parallel redundant system that allows two UPS models to operate in parallel and as backup for each other. The Master series (3P/1P) UPS also offers the option of adding on an isolation transformer to suit your requirements. • True Double-Conversion Online UPS • Wide input voltage range • DSP technology guarantees high performance • Output Power Factor 0.80 • Input Power Factor Correction 0.99 • Comes with a maintenance bypass function • Active power factor correction in all phases • Optional N+X parallel redundancy • 50/60Hz frequency converter mode • Emergency Power Off (EPO) function • Multiple communication interface (SNMP/USB/RS-232) • Isolation transformer (Optional) Rear Panel For 10kVA model 1. RS-232 communication port 1 2 3 4 5 5 6 2. USB communication port 3. Emergency power off function connector (EPO connector) 8 7 4. Share current port (only available for parallel model) 5. Parallel port (only available for parallel model) 14 8 6. Intelligent slot 7. Charger fan 8. Power stage fan 9 10 9. Maintenance by-pass switch 11 10. Input circuit breaker 12 13 11. Output circuit breaker for receptacles 12. Output receptacles: connect to mission-critical loads 13. Input/Output terminal 14. External battery connector (Only available for Long-run Model) PRO83110S/L 18
Online UPS For 15kVA to 30kVA model 1. RS-232 communication port 1 2 3 4 5 5 2. USB communication port 6 3. Emergency power off function connector (EPO connector) 8 4. Share current port (only available for parallel model) 7 5. Parallel port (only available for parallel model) 6. Intelligent slot 8 7 7. Charger fan 1 2 3 4 5 5 6 8. Power stage fan 8 9 10 9. Maintenance by-pass switch 7 10. Input circuit breaker 11 11. Output circuit breaker for receptacles 8 7 12. Output receptacles: connect to mission-critical loads 13. Input/Output terminal 14. Output Terminal: Connect to mission-critical loads 9 10 15. Programmable Output terminal: Connect to non-critical loads 16. External battery terminal (only available for Long-run model) 11 18 17. Utility input terminal 18. Grounding terminal (only available for parallel system) PRO83115L PRO83115S PRO83120L PRO83120S PRO83130S/L PRO83130L For 10K model For 15K & 30K model 18 14 15 17 14 15 16 17 Options • AS-400 Card (External alarm indicator) • SNMP Card for data communication via network connection • MODBUS Card (Communication interface) • Output Isolation Transformer 19
Online UPS Full Specifications MODELS PRO83110S/ L PRO83115S/ L PRO83120S/ L PRO83130 (S/L) Capacity 10 kVA 15 kVA 20 kVA 30kVA INPUT Nominal Voltage 3 x 400 VAC (3Ph+N) Voltage Range 305-478 VAC (3-phase) at 100% load Nominal Frequency 50 or 60Hz Frequency Range 46 ~ 64Hz Power Factor ≧ 0.99 OUTPUT Output Voltage 208/ 220/ 230/ 240VAC Static Regulation ±1% Frequency 50Hz or 60Hz auto selection or selectable Frequency Range 50 ~ 60Hz ± 0.1 Hz Power Factor 0.8 Current Crest Ratio 3:1 Liner Load ≦ 2% THD Voltage Distortion Non-Liner Load ≦ 5% THD Waveform Pure Sinewave EFFICIENCY AC Mode Up to 90% BATTERY Type Valve regulated Lead Acid battery (Maintenance free batteries) Capacity 9AH Standard Model Recharge Time (Typical) 9 hours recover to 90% capacity Charging Current 1.0 A (max) 2.0 A (max) 4.0 A (max) Type Depending on the application Long-Run Model Capacity Depending on the application Charging Current 4A 8A 12.0 A (max) OVERLOAD 100% < Load < 110% 10 minutes 110% < Load < 130% 1 minute >130% 1 second INDICATORS LCD Display Input / Output Voltage, Load Level, Batt Level, UPS Status, Fault Conditions PHYSICAL Dimension (mm) D x W × H 592 x 250 x 576 815 × 250 × 826 815 × 300 × 1000 Standard Model Net Weight (kgs) 83 164 234 Dimension (mm) D × W × H 592 ×250 × 576 592 x 250 x 576 815 × 250 × 826 Long-Run Model Net Weight (kgs) 28 40 64 ENVIRONMENT Protection IP20 Operation Humidity
Online UPS Master Series (3P/1P) - Rack Mount Online Master Series 10kVA – 20kVA Local Area Telecommunication Data 19” Rack Storage Emergency Network Devices Centre Mount PLCS Alarm (LAN) Devices Master Series (3P/1P) – Rack three-phase input / single-phase output, true online double conversion UPS system guarantees consistent and quality electrical power to protect your mission critical applications such as mid-sized business servers, telecommunication systems and industrial equipments. This (3P/1P) UPS is designed with a wide input voltage range to handle voltage fluctuating situations and a high accuracy output voltage to fail-safe your equipment. This Voltage Frequency Independent (VFI) system is available in capacities from 10kVA to 20kVA. By adopting the latest IGBT technology, this device is able offer excellent voltage switching characteristics during generator operation. An internal bypass system allowing continuous power is also integrated for convenience when maintenance is necessary. In addition, this device comes with a parallel redundant system that allows two UPS models to operate in parallel and as backup for each other. The Master series (3P/1P) – Rack UPS also offers the option of adding on an isolation transformer to suit your requirements. • True double-conversion • Eco mode operation for energy saving (ECO) • DSP technology guarantees high performance • Emergency power off function (EPO) • Output Power Factor 0.8 • Generator compatible • Wide input voltage range • Multiple communication interface (SNMP/USB/RS-232) • Active power factor correction in all phases • Adjustable battery numbers • 50Hz/60Hz frequency converter mode • Optional N+X parallel redundancy 4 4 4 Rear Panel 5 7 1 8 6 6 2 For 10kVA to 20kVA model 11 3 1. RS-232 communication port 9 12 10 2. USB communication port PRO83110RS/RL 3. Emergency power off function connector (EPO connector) 4. Parallel port (only available for parallel model) 5 7 1 5. Intelligent slot 2 6 6 6. Fan 9 3 7. External maintenance by-pass switch connection 12 4 8. Input circuit breaker 8 9. Input/Output terminal 10 6 6 4 10. Output terminal 4 11 11. Battery terminal 12. Input terminal PRO83120RS/RL 21
Online UPS Options • AS-400 Card (External Alarm Indicator) • SNMP Card for data communication via network connection • MODBUS Card (Communication interface) • Universal Rackmount Slider for installation in rack cabinets • External Maintenance Bypass Switch (Only available with 10kVA model) Full Specifications MODELS PRO83110RS/ RL PRO83120RS/ RL Capacity 10kVA 20kVA INPUT Nominal Voltage 3 x 400 VAC (3Ph+N) Voltage Range 305-478 VAC (3-phase) at 100% load Nominal Frequency 50 or 60Hz Frequency Range 46 ~ 64Hz Power Factor ≧ 0.99 OUTPUT Output Voltage 208/ 220/ 230/ 240VAC Static Regulation ±1% Frequency 50Hz or 60Hz auto selection or selectable Frequency Range 46 ~ 54Hz or 56 ~ 64Hz Power Factor 0.8 Current Crest Ratio 3:1 Linear Load ≦ 2% THD Voltage Distortion Non-Linear Load ≦ 5% THD Waveform Pure Sinewave EFFICIENCY AC Mode Up to 89% BATTERY Type Valve regulated Lead Acid battery (Maintenance free batteries) Capacity 9AH Standard Model Recharge Time (Typical) 9 hours recover to 90% capacity Charging Current 1.0 A (max) 2.0A (max) Type Depending on the application Long-Run Model Capacity Depending on the application Charging Current 4.0 A (max) OVERLOAD 100% < Load < 110% 10 minutes 110% < Load < 130% 1 minute >130% 1 second INDICATORS LCD Display Input/ Output Voltage, Load Level, Batt Level, UPS Status, Fault Conditions PHYSICAL UPS Unit: 668 x 438 x 133 (3U) UPS Unit: 668 x 438 x 266 (6U) Standard Model Dimension (mm) D x W × H Battery Pack: 580 x 438 x 133 (3U) BatteryPack: 580 x 438 x 133 (3U) x 2 UPS unit: 22 UPS unit: 45 Net Weight (kgs) Battery pack: 63 Battery pack: 63 x 2PCS Dimension (mm) D × W × H 668 x 438 x 133 (3U) 668 x 438 x 266 (6U) Long-Run Model Net Weight (kgs) 22 45 ENVIRONMENT Protection IP20 Operation Humidity
Online UPS Master Series (3P/3P) - Tower Online Master Series 10kVA – 30kVA Local Area Telecommunication Data Electro-Medical Storage Emergency E-Business Network Devices Centre Device PLCS Alarm (Server Farms, (LAN) Devices ISP/ASP/POP) Master Series (3P/3P) – Tower three-phase input / three-phase output, true online double conversion UPS system guarantees consistent and quality electrical power to protect your mission critical applications such as small server room, medical devices, telecommunication facilities and industrial processes. This (3P/3P) UPS is designed with a wide input voltage range to handle voltage fluctuating situations and a high accuracy output voltage to fail-safe your equipment. The Master Series (3P/3P) UPS system is available in capacities from 10kVA to 30kVA. By adopting the latest IGBT technology, this device is able offer excellent voltage-switching characteristics during generator operation. An internal bypass system allowing continuous power is also integrated for convenience when maintenance is necessary. In addition, this device comes with a parallel redundant system that allows two UPS models to operate in parallel and as backup for each other. The Tower series UPS also offers the option of adding on an isolation transformer to suit your requirements. • True Double-Conversion Online UPS • Wide input voltage range • DSP technology guarantees high performance • Output Power Factor of 0.80 • Input Power Factor Correction 0.99 • Comes with a maintenance bypass feature • Active power factor correction in all phases • Optional N+X parallel redundancy • 50/60Hz frequency converter mode • Emergency Power Off (EPO) function • Multiple communication interface (SNMP/USB/RS-232) • Isolation transformer (Optional) Rear Panel 1 2 3 4 5 6 For 10kVA to 30kVA model 8 7 1. RS-232 communication port 2. USB communication port 8 7 3. Emergency power off function connector (EPO connector) 4. Share current port (only available for parallel model) 9 11 10 13 5. Parallel port (only available for parallel model) 6. Intelligent slot 12 7. Charger fan 8. Power stage fan 9. Maintenance bypass switch 10. Bypass Input Circuit Breaker (Only available for dual input unit) 11. Input circuit breaker 12. Input/Output terminal PRO83310S/L 13. External battery terminal (only available for Long-run model) PRO83320S/L PRO83330S/L 23
Online UPS Options • AS-400 Card (External Alarm Indicator) • SNMP Card for data communication via network connection • MODBUS Card (Communication interface) • Output Isolation Transformer Full Specifications MODELS PRO83310S/ L PRO83320S/ L PRO83330S/ L Capacity 10kVA 20kVA 30kVA INPUT Nominal Voltage 3 x 400 VAC (3Ph+N) Voltage Range 300VAC
Online UPS Power Series Online Power Series 15kVA – 120kVA Local Area Telecommunication Data Electro-Medical Storage Emergency E-Business Network Devices Centre Device PLCS Alarm (Server Farms, (LAN) Devices ISP/ASP/POP) Power Series (3P/3P) three-phase input / three-phase output, true online double conversion UPS system guarantees to supply consistent and quality electrical power to protect your mission critical applications such as data centres, medical equipments and call centres. Harmful effects of harmonic injection are eliminated with the employment of Adaptive Feed Forward Cancellation (AFC) technology. With a UPS system that reflects low harmonic distortion and high input power factor, it is able to lower installation costs by utilizing smaller cables and miniature circuit breakers (MCB). Our team of specialists has gathered together to revolutionize the UPS usability by adding in a 5.7” LCD monitor display with all information and alarm notifications viewable within a single display. To ensure our products are user centered, our group of specialist has also adopted a front access concept to create a UPS system that is easy for users to carry out preventative maintenance and replacement activities. In addition, this device comes with a parallel redundant system that allows four UPS models to operate in parallel. An option of an additional isolation transformer is also available to suit your requirements. The Power series is available in models ranging from 15kVA to 120kVA. • Online double conversion technology with DSP control • Harmful effects of harmonic injection are eliminated with the employment of Adaptive Feed Forward Cancellation (AFC) technology • Very low input current distortion (THDi < 1%) • Input power factor 0.99 at 10% load • Output efficiency up to 95% • Control designed to withstand all kinds of loads • Variety of communication options available • Optional N+X parallel redundancy • Remaining backup time calculation • Optional isolation transformer 1 1 2 2 Rear Panel (Internal) 1 3 3 2 10 10 For 15kVA to 80kVA model 3 4 4 1. Relay interface 10 2. Emergency Power Off (EPO) 4 3. RS-232 COM ports 4. Intelligent Slow 5 6 7 8 5 6 7 8 5. Input circuit breaker 5 6 7 8 6. Maintenance bypass switch 9 9 9 7. Output switch 8. Battery switch 9. System Terminal PRO73315S/SI PRO73330S/SI PRO73360S/SI PRO73320S/SI PRO73340S/SI PRO73380S/SI 10. Parallel port (only available for parallel model) 25
Online UPS 1 For 100kVA to 120kVA model 3 2 1. Relay interface 10 2. Emergency Power Off (EPO) 4 3. RS-232 COM ports 4. Intelligent Slow 5. Input circuit breaker 6. Maintenance bypass switch 7. Output switch 5 6 7 8 8. Battery switch 9 9. System Terminal 10. Parallel port (only available for parallel model) PRO733100S PRO733120S Full Specifications MODELS PRO73315S/ SI PRO73320S/ SI PRO73330S/ SI PRO73340S/ SI PRO73360S/ SI PRO73380S/ SI Capacity 15kV 20kVA 30kVA 40kVA 60kVA 80kVA INPUT Nominal Voltage 3 x 400V (3Ph + N) Voltage Range 300VAC
Online UPS MODELS PRO733100S PRO733120S Capacity 100kVA 120kVA INPUT Nominal Voltage 3 x 400V (3Ph + N) Voltage Range 300VAC
Online UPS The Most Versatile Solution For Power Input Power Factor 0.99 At 10% Load Protection Lower power losses would result in reduced The Power Series is designed with the new state of art consumption, lower operation and maintenance costs. transformerless PWM technology that can be easily INPUT POWER FACTOR adapted to any kinds of complicated loads such as the 1,20 non-linear systems (IT systems), highly inductive/ capacitive loads, high-density discharge lamps and 1,00 induction motors. The Power series is designed with 2 0,80 important criterions in mind; maximum efficiency and PFin 0,60 energy conservation. The unit also comes with a small 0,40 form factor to allow for minimum installation effort. Furthermore, a parallel redundant system is integrated to 0,20 allow two UPS models to operate in parallel as backup 0,00 for each other. The Power Series is available in 0% 25% 50% LOAD capacities ranging from 15 to 120kVA. Output Efficiency of up to 95% Online Double Conversion Technology with DSP Control Designed with a DSP controller and fourth generation IGBT transistors, the UPS is able to achieve extremely The Power Series is able provide a higher load up-time high efficiency of up to 95%. With such high ratings, and effective insulation against network disturbance components in the UPS are not only protected but also with its online double conversion technology. A Digital prolonged due to the decrease in heat losses. Signal Processor (DSP) controller improves the performance and efficiency of the UPS. SERIES TIPICAL EFFICIENCY 100% 75% EFFICIENCY 50% Advanced Control with Adaptive Feed Forward Cancellation (AFC) Technology 25% By cancelling both the input current and the output voltage harmonics, the harmful effects of harmonic 0% 0% 25% 50% injection can be eliminated and this enhances the load LOAD integrity. Small Form Factor Low Input Current Distortion (THDi < 1%) Utilizes a transformerless technology allows the design AFC cells are used to achieve extremely low distortion of the UPS to be lighter and smaller. values. The Power series is able to obtain a low input current distortion at THDi < 1% under full load and a THDi < 5% under smaller load (i.e. 10% of load). This will prevent distortion of electrical network upstream and thus, result in the reduction of cable usage and protective devices in the electrical network. 28
Online UPS Front Access concept Variety Of Communications And Option An important consideration has Available been given during the UPS design The UPS has provided the following standard phase to create a system that communication selections: allows users to access the • Relay interface unit’s electronic cards and power • RS-232/485 port components with minimum • 1 × SNMP slot effort. All electronic boards and • Modbus RTU / SEC protocol components can be accessed • 2 × connectors for parallel connection from the front panel for easy maintenance and replacement activities. Made of 60% Recyclable Materials When it comes to conserving the environment, PROLiNK is committed to play a part by designing their UPS Versatile Single-Phase / Three-Phase set-ups products using recyclable materials. This highly versatile UPS is designed with different types of setting-up options; • Three-phase input / Three-phase output (III/III) • Three-phase input / Single phase output (III/I) Back-up Time indicator With the use of simple algorithms, an estimated remaining back-up time can be calculated and indications will be reflected on a LCD panel. Control Components are designed to with stand all kinds of loads In the Power Series, the control components are designed to withstand all types of loads. These include loads such as; resistive, capacitive, non-linear, 5.7” Multiple Languages Graphical LCD high-density discharge lamps, induction motors, speed Display drives etc. This makes the UPS extremely compatible Our team of specialists has gathered together to with many types of electronics. Better yet, the UPS revolutionize the UPS usability by adding in a 5.7” LCD comes with a wide array of parameters that can be monitor display with all information and alarm programmed locally or remotely to fit different types of notifications viewable within a single display. environment. N+1 Redundancy A parallel redundant system allows 4 UPS models to operate in parallel and as backup for each other. 29
Online UPS PPM Series PROLiNK Power Modular (PPM) UPS System Local Area Telecommunication Data Electro-Medical Storage Emergency E-Business Network Devices Centre Device PLCS Alarm (Server Farms, (LAN) Devices ISP/ASP/POP) PROLiNK PPM Series modular three-phase input / three-phase output online double conversion UPS takes scalability to a whole new level. Based on a scalable design, the PPM comes with a wide range of capacity, ranging from as low as 30kVA to as high as 210kVA. The PPM series is designed with a N+X parallel redundancy system that allows two or more UPS modules to operate in parallel and as back-up for each other. This unit provides an ideal protection for data centers, telecommunication facilities and other critical applications. Up to seven 30kVA modules can be fitted into a standard cabinet to simplify maintenance and replacement activities. The PPM Series guarantees a low mean-time-to-repair (MTTR), giving users a shorter elapsed time between the point of repair and the point of equipment recovery. • N+1 parallel redundancy • Online double conversion technology • Output Power Factor of 1 • Modular design decreases MTTR • High scalability • Internal maintenance bypass available • Adjustable charging current • Highly interactive 5.7" LCD design High Efficiency Online Double Conversion High Scalability Technology Based on a scalable design, the PPM Series simplifies PROLiNK PPM is designed with the latest online double future expansion by making UPS units easily upgradable. conversion technology that provides a high efficiency This architecture allows you to meet power demands by rating of 96%. With such a high efficiency rating, the PPM adding additional modules vertically in a single rack can save you hundreds of dollars each year. enclosure. Unity Output Power Factor Modular Design Lowers MTTR With a unity output factor (kVA = kW), the PROLiNK The modular design ensures uninterrupted power supply PPM UPS system is 100% compatible with today's high during UPS maintaining and replacing activities. Also, the power factor loads. It is able to meet the latest PPM Series guarantees a low mean-time-to-repair server requirements, giving the best value for your IT (MTTR), giving users a shorter elapsed time between the investments. point of repair and the point of equipment recovery. 30
Online UPS N+X Parallel Redundancy Ease Of Installation and Maintenance The PPM series is designed with a N+X parallel With a built-in maintenance bypass feature, the UPS is redundancy system that allows two or more UPS able to deliver continuous power to the critical load modules to operate in parallel and as back-up for each during maintenance. Better yet, the PPS comes with a other. front access concept to facilitate installation. Adjustable Charging Current High Overload Capability PROLiNK PPM comes with a maximum charging current PROLiNK PPM supports 110% overload for 60 minutes, of up to 8A for each individual module. The charging 120% for 10 minutes and 150% for 1 minute. current can be adjusted based on the necessary requirement. 5.7” LCD Graphic Mimic Panel A multilingual 5.7" graphic LCD screen is integrated as part of the design to provide users with visual information and advanced control abilities. PPM90 The PROLiNK PPM90 is a compact stand alone UPS system that provides the best backup solution for small and medium loads. This unit comes with a standard EIA height of 30U and is able to fit capacities ranging from 30kVA to 90kVA in the same cabinet. With features such as N+1 redundancy and the capability for future expansion, the PROLiNK PPM90 is definitely able to make your backup experience an absolute cinch. No. Of Module Capacity Dimension 1 30kVA 2 60kVA 600 x 1100 x 1485 (30U) mm 3 90kVA Exterior Interior PPM210 The PROLiNK PPM210 is a standalone UPS system that comes with a standard EIA height of 42U. This unit is able to fit 7 x 30kVA modular redundancy in the same cabinet. Even better, the PPM210 has the capability to manage future capacity expansion of up to 210kVA, making the PPM210 the best backup solution for greater loads. No. Of Module Capacity Dimension 1 30kVA 2 60kVA 3 90kVA 4 120kVA 600 x 1100 x 2030 (42U) mm 5 150kVA 6 180kVA 7 210kVA Exterior Interior 31
You can also read