TEKAPO SPIGOT PS1 - Boundaryline
←
→
Page content transcription
If your browser does not render page correctly, please read the page content below
TITAN PS1 PRODUCER STATEMENT - PS1 Issue Date: 22 Jun 2020 Revision No. 1.01 TEKAPO SPIGOT PS1 STRUCTURAL DESIGN REPORT, JOB J001856 Boundaryline - Very high wind zone, various location 0800 003 006 / boundaryline.co.nz 1
GD C Consultants Ltd Chartered Professional Engineers & Mediators Structural Design Report This report has been prepared for Boundaryline by GDC Consultants Ltd (GDC). No liability is accepted by this company or any employee or sub-consultant of this company with respect to its use by any other parties. This disclaimer shall apply notwithstanding that the report may be made available to other persons for an application for permission or approval to fulfil a legal requirement Cantilever glass balustrade and pool fence Structural Design, very high wind zone, various location Status For consent Revision 0 Quality Assurance Statement Task Res onsibilit Si nature & Date Alin Poanta Prepared by: MEngNZ No. 1027581 Reviewed by Mike Osborne CMEng NZ No.212452 Peer - Reviewed by Matt Bishop CPEng No. 243276 Clement Fernando Approved for Issue by: CPEng. No. 202146 Job No: J001856 Date: June 2020 HBI House, 6C Taradale Road, Napier, 41101 Offices in: Hamilton! Thames! Whitiangal Rotorual Auckland! Napier! Asia Website: www.gdcgroup.co.nz Specialising in Civil, Structural, Environmental & Training Structural Design Report, Job J001856 Boundaryline - very high wind zone, various location June 2020
Section 1 – PS1 Structural Design Report, Job J001856 Boundaryline – very high wind zone, various location June 2020
B1 , F2 Building Code Clause(s)……………………….. PRODUCER STATEMENT – PS2 – DESIGN REVIEW (Guidance on use of Producer Statements (formerly page 2) is available at www.engineeringnz.org) ISSUED BY: ……..………………………………………………………………………………………………………………….…… BVT Consulting Ltd (Design Review Firm) Boundaryline TO:………………………………………………………..…………………………………………………………………………..…… (Owner/Developer) TO BE SUPPLIED TO:…………………………………………………………………………………………………….……….…… Various Councils (Building Consent Authority) Design Review of Cantilever Glass Balustrade - Spigot 5 as per GDC Consultants Engineers PS1 J001856 IN RESPECT OF:…………………………………………………………………………………………….……………………….…. (Description of Building Work) AT:………………………………………………………………………………………………………………………….………….….. Various Locations (Address) Town/City:……………..………………………...…..… LOT…………….....…………… DP………………… SO………………… (Address) BVT Consulting Ltd Boundaryline We …………..………..…………………………..…..… have been engaged by …………..………….……………….......………. (Design Review Firm) B1, F2 to review the design documents for this project in respect of the requirements of Clause(s) ……………………….…………. of the Building Code. The Review is for All GDC Consultants Ltd or ■ Part only of the design work prepared by …………………………………………………….… (Design Firm) Cantilever Glass Balustrade & Pool Fence - Spigot 5 as described in drawings titled ..…………………..………………………………………………………………………………… and numbered …………………………………………….………………. J001856-03 together with the specification, and other documents set out in the schedule attached to this statement according to which the building is proposed to be constructed. spigot and anchor design The Review is in respect of ………………………….………………………………………………..… or per attached schedule. (aspects of design) The Review confirms that these aspects of the design are in accordance with: B1/VM1 ■ Compliance Documents issued by the Ministry of Business, Innovation & Employment………………..……………...….or (verification method/acceptable solution) Alternative solution as per the attached schedule…………………….……………………………………………………..…… On behalf of the firm undertaking this review, on the basis of the review undertaken, and subject to: (i) Site verification of the following design assumptions …………See attached report……………………..……………..… (ii) All proprietary products meeting their performance specification requirements; I believe on reasonable grounds that a) the building, if constructed in accordance with the drawings, specifications, and other documents provided or listed in the attached schedule, will comply with the relevant provisions of the Building Code and that b), the persons who have undertaken the review have the necessary competency to do so. Matt Bishop I, …………..………..………………………………….....…..………. 243276 am: ■ CPEng ……….….. # Reg Arch …….…….. # (Name of Design Review Professional) I am a member of: ■ Engineering New Zealand BE(Hons) NZIA and hold the following qualifications:……………………………. The Design Review Firm issuing this statement holds a current policy of Professional Indemnity Insurance no less than $200,000*. The Design Review Firm is a member of ACENZ: ■ Matt Bishop SIGNED BY……………………….…………………………………………………..(Signature)……….…………..……………...… (Name of Design Review Professional) ON BEHALF OF BVT 22 June 2020 ……..……………………………………………………………………………………………..Date……..…….… Consulting Ltd (Design Review Firm) Note: This statement shall only be relied upon by the Building Consent Authority named above. Liability under this statement accrues to the Design Review Firm only. The total maximum amount of damages payable arising from this statement and all other statements provided to the Building Consent Authority in relation to this building work, whether in contract, tort or otherwise (including negligence), is limited to the sum of $200,000*. This form is to accompany Form 2 of the Building (Forms) Regulations 2004 for the application of a Building Consent. THIS FORM AND ITS CONDITIONS ARE COPYRIGHT TO ACENZ, ENGINEERING NEW ZEALAND AND NZIA PRODUCER STATEMENT PS2 October 2013 (PDF)
Peer Review Summary Overview BVT has conducted a peer review of GDC Consultants PS1 on glass balustrade spigots and anchors to be installed at various locations in New Zealand. BVT has reviewed the component of the PS1 covering Clause B1 (Structure) of the NZ Building Code. Items raised by BVT and the responses from GDC Consulants are outlined in the RFI summary sheet in Appendix B. Key Outcomes The spigots and anchors specified in the PS1 design are reasonable for use with 1.2x1.4 m toughened glass panels. Calculations verify that the spigots are suitable for fastening 12 mm toughened glass panels at wind speeds up to 50 m/s, classified as Very High Wind Zones in NZS 3604-2011. We believe that the designs of the spigots are in compliance with AS/NZS 1170.2 and the Department of Building and Housing’s Guidance on Barrier Design. A PS2 can therefore be issued based on this review. Project Contacts Review Engineer: Daniel Bulbring Chartered Engineer: Matt Bishop CPEng CMEngNZ All information, details or designs portrayed in this document remain the copyright of BVT Consulting Limited (unless BVT has expressly agreed otherwise with the Client). Any reproduction without the express permission of BVT Consulting Ltd is prohibited. This report has been prepared by BVT on the specific instructions of our Client. It is solely for our Client’s use for the purpose for which it is intended in accordance with the agreed scope of work. Any use or reliance by any person contrary to the above, to which BVT has not given its prior written consent, is at that person’s risk. BVT Revision A 19061267
Section 2 – B2 Compliance Structural Design Report, Job J001856 Boundaryline – very high wind zone, various location June 2020
H B I House, 6C Taradale Road PO Box 44, Napier +64 6 281 2270 napier@gdcgroup.co.nz W: www.gdcgroup.co.nz June 2020 Ref.: Job J001856 To Various Councils Attention: Building officer Dear Building consent officer, Re: B2 Compliance Cantilever Glass Balustrade – Spigot design as per GDC Consultants J001856 You have requested a Producer Statement for Design – PS1 for clause B2 of the Building Code – Structural Durability. We are not able to provide this because there is no effective verification method for B2 contained within the Building Code. However we can confirm that for the structural element shown in our documentation: Steel Steel protection has been specified in accordance with AS/NZS 2312.1:2014 “Guide to the protection of structural steel against atmospheric corrosion by the use of protective coatings Part1: Paint coatings”. We note that this is on a time first maintenance basis The spigots are made of Duplex 2205 Stainless Steel. Mechanical properties of 2205 grade stainless steels are in accordance with ASTM A276 / A276M - 17 Standard Specification for Stainless Steel Bars and Shapes. The spigots are manufactured according to ISO 16468:2015 which specifies technical requirements for castings produced by the investment-casting process. The International Standards specifying metallurgical material requirements for grade 2205 steel. We trust that this provides the information that you are seeking. Should you have further queries, please contact the undersigned. Yours faithfully Alin Poanta Structural Engineer For GDC Consultants Ltd OFFICES : HAMILTON – THAMES – ROTORUA - WHITIANGA – NAPIER – AUCKLAND - WELLINGTON - ASIA
Section 3 – F2 Compliance Structural Design Report, Job J001856 Boundaryline – very high wind zone, various location June 2020
SAFETY GLASS CERTIFICATION SAFETY GLASS CERTIFICATION F2: COMPLIANCE STATEMENT OF COMPLIANCE To satisfy the New Zealand Building Code Acceptable Solution F2/AS1, glass likely to come into contact with people must comply with NZS 4223: Part 3:2016 Code of practice for glazing in buildings – Human impact safety requirements. NZS 4223: Part 3:2016 requires Grade A safety glass to be used in shower doors, shower screens and bath enclosures and Glass Pool Fencing. Boundaryline confirms glass used in our Glass Pool Fencing and Balustrade has been produced to one or more of the following standards as outlined in Appendix 3.B of NZS 4223:Part 3:2016: AS/NZS 2208 Grade A BS 6206 Grade A ANSI Z97.1 Peter Carney GENERAL MANAGER M: 0800 235 2473 I sales@belairefencing.co.nz 2 Waitane Place | Onekawa, Napier | New Zealand 3116 Tel: +64 6 8785 752 | Mob: +64 21 220 1403 | Fax: +64 6 8785 758 June 2020
MATERIALS & TESTING LABORATORIES LIMITED Destructive & Non-destructive Test House CERTIFICATE OF TEST Report No. 42653/2 Page 1 of 3 pages Reference: BELAIRE DESIGNER FENCING Order No.: PETER Attention: Mr Peter Carney Load Testing on 1400mm Long x 1200mm High Uniglass Infill Panel Test Standard/ Method: Method as discussed with client Test Equipment: Riken P-4 Pump, Serial No. 22968 with AEP Digital Force Gauge, Serial No. 109626 SPX 5 Ton, Model B No. C55C Single Ram (all verified against Shimadzu Universal Grade 1 Testing Machine, Model No. REH 50, Serial No. 72666. Calibration due June 2016). Kristeel LAD 1 0-600mm RESULTS: 1 x Uniglass infill panel 1400mm long x 1200mm high, mounted to 2 x stainless steel spigots. 3 x Separate load tests performed: Maximumlload vs Deflection at maximum load and Permanent Set recorded. Test 1: 240kg Distributed Through a 960 x 960mm Timber Load Board Applied Force Deflection at Maximum Load (kg) (mm) 0 0 30 8 60 23 90 44 120 57 150 71 180 82 210 93 240 105 Permanent Set= 12mm - No failure observed. Certificate of Test 20 15 dotx . Document Date 1 I /02/15 Rev 0 P.O. BOX 14-042, PANMURE 1741, 172g MARUA RD, MT WELLINGTON, AUCKLAND, N.Z. TEL: 579 0262 FAX: 579 0260 Email: admin@mtlabs.co.nz
Section 4 – Drawings Structural Design Report, Job J001856 Boundaryline – very high wind zone, various location June 2020
BOUNDARYLINE CANTILEVER GLASS BALUSTRADE & POOL FENCE SPIGOTS (SPIGOT 5) NEW ZEALAND DRAWING REGISTER 1. GENERAL NOTES J001856 - 01 REVISION 0 2. NOTES & PS4 J001856 - 02 REVISION 0 3. LAYOUT & DETAILS J001856 - 03 REVISION 0 GDC Consultants Ltd CharteredProfessionalEngineers&Mediators FOR CONSENT JOB NO: J001856
NOTES GENERAL G1 STRUCTURAL DRAWINGS SHALL BE READ IN CONJUNCTION INSPECTIONS WITH THE SPECIFICATION, ARCHITECTURAL, CIVIL AND ENGINEERING SERVICES DOCUMENTS. G2 NO DIMENSIONS ARE TO BE OBTAINED FROM SCALING DRAWINGS U.N.O. I1. CHECK THE BUILDING CONSENT CONDITIONS FOR ANY INSPECTIONS THAT ARE REQUIRED BY THE BUILDING CONSENT AUTHORITY (BCA). G3 UNLESS OTHERWISE NOTED ALL LEVELS ARE IN METRES AND ALL DIMENSIONS ARE IN MILLIMETRES. G4 THE BUILDER SHALL BE RESPONSIBLE FOR MAINTAINING THE STABILITY OF THE STRUCTURE UNTIL ITS COMPLETION I2. IT IS INCREASINGLY COMMON FOR BUILDING CONSENT AUTHORITIES AND SHALL ENSURE THAT NO PART OF THE STRUCTURE IS TO REQUIRE A "PS4" FOR SPECIFICALLY DESIGNED STRUCTURES. OVERSTRESSED BY EXCESSIVE LOADING. G5 ALL MATERIALS AND WORKMANSHIP SHALL BE IN ACCORDANCE CONFIRM WITH BCA AND GDC CONSULTANTS THE SCOPE AND TYPE WITH THE CURRENT CODES OF PRACTICE EXCEPT WHERE VARIED BY THE SPECIFICATION AND/OR DRAWINGS. OR REQUIRED INSPECTIONS FOR GDC CONSULTANTS LTD. TO ISSUE ISO 16468 - INVESTMENT CASTINGS THIS AS WE NEED TO CARRY OUT INSPECTIONS AS PER THE BUILDING G6 LEGEND USED FOR GENERAL ABBREVIATIONS CONSENT REQUIREMENTS. RING GDC CONSULTANTS LTD. LOCAL TYP TYPICAL NTS NOT TO SCALE OFFICE TO ARRANGE BOOKING. SFL FFL STRUCTURAL FLOOR LEVEL. FINISHED FLOOR LEVEL (NO INSPECTION EQUALS NO PS4 ISSUED) SOP SET OUT POINT UNO UNLESS NOTED OTHERWISE FL FOUNDING LEVEL (IE UNDERSIDE OF FOOTING) I3. GDC MUST SEE STAMPED BUILDING CONSENT DRAWINGS BEFORE AN G7 WHERE PROPRIETARY PRODUCTS ARE SPECIFIED IN THE DOCUMENTS THE INSPECTION CAN BE CARRIED OUT. CONTRACTOR MAY NOT SUBMIT AN ALTERNATIVE PRODUCT FOR APPROVAL. I4. CONTRACTOR TO SUPPLY PS3 OR LICENCED BUILDING PRACTITIONER (LBP) WITH SIGNED GDC DRAWINGS AFTER CONSTRUCTION. I5. REQUIRED INSPECTIONS SCHEDULE MUST BE UNDERTAKEN BY THE ENGINEER - BALLUSTRADE SPIGOT MANUFACTURE I6. IT IS THE BUILDING CONSENT APPLICANT'S( OR AUTHORIZED AGENT) REV REVISION DETAILS APPD DATE RESPONSIBILITY TO ENSURE THAT GDC CONSULTANTS LTD. IS NOTIFIED IN A person using GDC drawings and other data accepts the risk of: ADVANCE OF THE REQUIRED INSPECTION. WE CANNOT ISSUE PS4 FOR ITEMS WE 1. Using the drawings and other data in electronic form without requesting and checking them for accuracy against the original hard copy versions; 2. Using the drawings or other data for any purpose not agreed to in writing by GDC DID NOT INSPECT. BOOKING SHOULD BE MADE 48 HOURS PRIOR TO DESIRED TIME OF INSPECTION. 489 Anglesea Street PO Box 9403 I7. DURABILITY. IF COUNCIL REQUIRES B2-DURABILITY SIGN OFF ON THE PS4, THE Hamilton 3204 CONTRACTOR NEEDS TO PROVIDE QUALITY CERTIFICATES SUCH AS TIMBER Consultants Ltd Ph. (07) 838 0090 GRADE, STEEL GRADE, CONCRETE STRENGTH, PILE DRIVING RESULTS AND ANY Chartered Professional Engineers & mediators OTHER RECORDS TO DEMONSTRATE THAT THE BUILDING WAS CONSTRUCTED IN Also at : Thames Whitianga Rotorua Napier Wellington Auckland ACCORDANCE WITH THE SPECIFIED DESIGN REQUIREMENTS AND SPECIFICATION. Web: www.gdcgroup.co.nz Email: hamilton@gdcgroup.co.nz THIS INFORMATION TO BE PROVIDED TOGETHER WITH THE PS3 CERTIFICATE TO THE ENGINEER SO THAT HE/SHE IS ABLE TO ISSUE A PS4 CERTIFICATE FOR THE Client: PROJECT. BOUNDARYLINE I8. IF EQUIVALENT PRODUCTS ARE TO BE USED IN PLACE OF THE SPECIFIED NEW ZEALAND WIDE PRODUCT ON DRAWINGS, THE ENGINEER MUST BE INFORMED AND AGREE TO THE SUBSTITUTION IN WRITING. Project: CANTILEVER GLASS BALUSTRADE & POOL FENCE SPIGOT 5 Drawing Title: GENERAL NOTES JOB No. J001856 DESIGNED A.P CAD No. J001856 DRAWN J.F DATE FEB 2020 CHECKED A.P DATE FEB 2020 APPROVED C.F ORIGINAL SCALES AS SHOWN @ A3 DRAWING No. SHEET REV. 1 0 J001856-01 OF 2
NOTES 1400 - SPIGOTS TO BE MANUFACTURE ACCORDING TO ISO 16468 : 2015 - FOR TIMBER MEMBERS BEING LESS THAN 90mm WIDE USE A DIFFERENT TYPE OF SPIGOT - MINIMUM TIMBER MEMBER DEPTH FOR FIXING THE SCREWS INTO IS 150mm 12mm TOUGHENED SAFETY GLASS - COACH SCREW PENETRATION TO BE MINIMUM 140mm 1200 FOR CONSENT 1 1 SPIGOT TYPE 5 REV REVISION DETAILS APPD DATE - - A person using GDC drawings and other data accepts the risk of: SCALE 1:5 1. Using the drawings and other data in electronic form without requesting and checking them for accuracy against the original hard copy versions; 2. Using the drawings or other data for any purpose not agreed to in writing by GDC 45 45 489 Anglesea Street PO Box 9403 SPIGOT SPIGOT 45 45 Hamilton 3204 Consultants Ltd Ph. (07) 838 0090 Chartered Professional Engineers & mediators EDGE OF TIMBER Also at : Thames Whitianga Rotorua Napier Wellington Auckland Web: www.gdcgroup.co.nz Email: hamilton@gdcgroup.co.nz 300 800 300 TIMBER BLOCKING Client: BOUNDARYLINE NEW ZEALAND WIDE TIMBER MEMBERS BY OTHERS GLASS FENCE SUPPORTED BY STAINLESS STEEL SPIGOTS MINIMUM 90mm WIDE SCALE 1:10 Project: PLAN VIEW ON TIMBER CONNECTION CANTILEVER GLASS SCALE 1:10 BALUSTRADE & POOL FENCE SS SPIGOT SS SPIGOT SPIGOT 5 12mm TOUGHENED 12mm TOUGHENED SS SPIGOT 25 MINIMUM SAFTEY GLASS 4/M10 STAINLESS STEEL SAFTEY GLASS 12mm TOUGHENED EDGE DISTANCE Drawing Title: CHEMSET BOLTS SAFTEY GLASS 4/M10 BOLTS OR 4/M10 COACHSCREWS 4/M10 S/S BOLTS CENTRALLY PLACED TO TIMBER MEMBERS. SPIGOT FIXING CONCRETE SLAB EPCON C6 EPOXY 100mm EMBEDMENT SPIGOT BASE PLATE NO FIXINGS TO THE 25MPa STRENGTH TIMBER ENDS 115 8mm STEEL PLATE 6mm FWAR TO JOB No. J001856 DESIGNED A.P 100 MINIMUM CONCRETE STEEL CAD No. J001856 DRAWN J.F EDGE DISTANCE DATE FEB 2020 CHECKED A.P DATE FEB 2020 APPROVED K.W 1 SECTION TO CONCRETE SECTION 1 TO STEEL SECTION 1 TO TIMBER SCALE 1:10 - SCALE 1:10 - SCALE 1:10 - ORIGINAL SCALES AS SHOWN @ A3 DRAWING No. SHEET REV. 2 0 J001856-02 OF 2
Section 5 – Self Closing Gates Compliant With F9 Structural Design Report, Job J001856 Boundaryline – very high wind zone, various location June 2020
Frameless Glass Pool Fencing Glass Gate Hardware Compliance Glass Gate Self Closing Hinges All Glass And Hardware Has Been tested to AS1926.1 - 2012, A full report is available on Request. - Gate Material: 10mm Toughened Glass - Gate Size: 1200mm high x 900mm wide - Lock Description:Magnalatch - Hinge Descption: Self Closing Spring hinge gate - Lock On Inside of Barrier: Yes - Self Closing from all angles: Yes - Self Closing from 150mm of open: Yes - Overall Gate Height: 1250mm 20 18 102.2 6.3 48 80 10 21 4 20 20 4 50 50 106.3
Frameless Glass Pool Fencing Glass Gate Hardware Compliance Glass Gate Self Locking Gate Latch self closing hinge Self Locking Latch self closing hinge self closing spring hinge Below Is a photo of the Testing Setup to comply with AS1926.1 - 2012 18 10 21 4 20 20 50 50 self closing gate latch 10mm gate 12mm panel 15mm
0800 003 006 / boundaryline.co.nz
You can also read