Roto Safe cable junction - Matching hardware technology everything about doors Window and Door Technology Installation, maintenance and operation ...
←
→
Page content transcription
If your browser does not render page correctly, please read the page content below
Window and Door Technology Roto Safe cable junction Matching hardware technology everything about doors Installation, maintenance and operation instructions for timber, PVC and aluminium profiles
Contact Contact Roto Frank Fenster- und Türtechnologie GmbH Wilhelm-Frank-Platz 1 70771 Leinfelden-Echterdingen Germany Phone +49 711 7598 0 Fax +49 711 7598 253 info@roto-frank.com www.roto-frank.com 2 · 05 / 2020 · IMO_502_EN_v2 Roto Safe - Cable junctions Subject to change.
Table of contents 1 General information.................................................................................................6 1.1 Version history........................................................................................................................ 6 1.2 Instructions............................................................................................................................. 6 1.3 Symbols.................................................................................................................................. 7 1.4 Pictographs............................................................................................................................. 7 1.5 Abbreviations.......................................................................................................................... 7 1.6 Explanation of terms............................................................................................................... 8 1.7 Target groups..........................................................................................................................8 1.8 Fabricator................................................................................................................................ 9 1.9 Target groups’ obligation to give instructions........................................................................ 9 1.10 Copyright protection............................................................................................................. 10 1.11 Limitation of liability.............................................................................................................. 10 1.12 Preserving the surface finish.................................................................................................10 2 Security................................................................................................................. 12 2.1 Presentation and structure of warning instructions..............................................................12 2.2 Security levels of warning instructions................................................................................. 12 2.3 Basic safety information........................................................................................................12 2.3.1 Installation.............................................................................................................................13 2.3.2 Use........................................................................................................................................13 2.3.3 Ambient conditions...............................................................................................................14 2.3.4 Stipulated use....................................................................................................................... 15 2.3.4.1 Misuse.................................................................................................................................. 15 2.4 Operation.............................................................................................................................. 15 3 Information on the product................................................................................... 17 3.1 Overview............................................................................................................................... 17 3.2 Technical data....................................................................................................................... 18 3.3 Bush and connector..............................................................................................................19 3.4 Overview of variants............................................................................................................. 20 4 Installation.............................................................................................................24 4.1 Processing instructions.........................................................................................................24 4.2 Dimensions........................................................................................................................... 24 Subject to change. Roto Safe - Cable junctions IMO_502_EN_v2 · 05 / 2020 · 3
Table of contents 4.3 Drilling and routing dimensions............................................................................................ 26 4.4 Installation.............................................................................................................................28 5 Connection diagram.............................................................................................. 32 5.1 Eneo A / AF with Phone & Code, power supply unit in general........................................... 33 5.2 Eneo C / CC / CF with Phone & Code, power supply unit in general....................................34 6 Operation...............................................................................................................35 6.1 Fault assistance.....................................................................................................................35 6.2 Performance test...................................................................................................................35 7 Maintenance..........................................................................................................36 7.1 Maintenance intervals...........................................................................................................37 7.2 Cleaning................................................................................................................................ 37 7.3 Performance test...................................................................................................................37 7.4 Repair....................................................................................................................................39 8 Dismantling........................................................................................................... 40 8.1 Dismantling...........................................................................................................................40 9 Transport............................................................................................................... 41 9.1 Transporting elements and hardware................................................................................... 41 9.2 Storing the hardware............................................................................................................ 42 9.3 Transport inspection............................................................................................................. 42 10 Disposal.................................................................................................................43 10.1 Disposing of packaging........................................................................................................ 43 10.2 Disposing of hardware..........................................................................................................43 10.3 Electronic waste....................................................................................................................43 11 Accessories........................................................................................................... 44 11.1 Cable..................................................................................................................................... 44 11.2 Retaining bracket.................................................................................................................. 44 11.3 Cover plate............................................................................................................................ 45 11.4 Eneo power supply unit........................................................................................................ 47 11.5 Eneo connector set............................................................................................................... 47 4 · 05 / 2020 · IMO_502_EN_v2 Roto Safe - Cable junctions Subject to change.
Table of contents 12 Additional information...........................................................................................48 12.1 Declaration of Conformity.....................................................................................................48 Subject to change. Roto Safe - Cable junctions IMO_502_EN_v2 · 05 / 2020 · 5
General information 1 General information 1.1 Version history Version Date Changes v0 17.04.2019 Publication v1 12.11.2019 Overview drawing of installation situation from page 20 v2 26.05.2020 Cable junction 820255 with built-in cover plate from page 17 Routing dimensions corrected from page 26 1.2 Instructions This manual contains important information, instructions, application diagrams (max. sash sizes and weights) and assembly instructions for the installation, maintenance and operation of hardware. The information and instructions contained in this document refer to products belonging to the Roto hardware system named on the front page. All steps must be completed in sequence. The following documents apply in addition to these instructions: ■ Roto Safe catalogue: CTL_86 ■ Roto Safe Eneo connection diagrams: IMO_310 ■ Roto Safe Eneo C / CC / CF installation instructions: IMO_438 ■ Brief instructions Roto Safe Eneo A / AF and Eneo C / CC / CF: SUG_11 Power supply unit specifications: SUG_3 ■ Instructions and information relating to the individual hardware ■ The applicable regulations, directives and national laws Storing the instructions These instructions are an important part of the product. The instructions must be stored so that they are always to hand. Explanation of the markings The manual uses the following markings for emphasis (e.g. in figures or instructions): Marking Meaning Sash Frame Drill holes, routing or screw positions Unaffected components Indirectly affected components Components that have just been described Arrows or movements 1 Item number [1] Legend [A] Steps 6 · 05 / 2020 · IMO_502_EN_v2 Roto Safe - Cable junctions Subject to change.
General information Symbols INFO Any dimensions without a unit in the instructions are given in millimetres (mm). Other units of measurement are clearly indicated by the presence of the differing unit. INFO Figures are provided in the right-hand version (DIN 107). 1.3 Symbols Symbol Meaning First-level list Second-level list (Cross-)reference Result Unnumbered step 1. Numbered step a. Numbered second-level step Requirement 1.4 Pictographs Symbol Meaning Timber, PVC and aluminium Material number Packaging unit Additional information 1.5 Abbreviations Abbreviation Meaning A Amperes W Width C Celsius approx. approximately CTL Catalogue etc. et cetera H Height IMO Installation instructions kg Kilograms m Metres Mat. no. Material number max. Maximum mm Millimetres mm2 Square millimetres D Depth V Volts Subject to change. Roto Safe - Cable junctions IMO_502_EN_v2 · 05 / 2020 · 7
General information Explanation of terms Abbreviation Meaning e.g. for example 1.6 Explanation of terms Locking The term “locking” refers to the deadbolt in the main lock and the additional locking systems, used to lock the door securely. Door secured The term “door secured” means that the door is secured using the latch in the main lock but is not locked. Actuating the door lever handle causes the latch to retract, allowing the door to be opened. Door locked The term “door locked” means that the door is secured by an unsprung rigid deadbolt that has been pushed out of the main lock, and / or additionally by other additional locking systems. All locking elements engage in corre- sponding recesses in the door frame, or striker plates, the lock casing, etc. 1.7 Target groups The information in this document is directed at the following target groups: Hardware dealers The “hardware dealers” target group includes all companies and individuals that purchase hardware from hardware manufacturers for resale, without modifying or further processing the hardware. Door manufacturers The “door manufacturers” target group includes all companies and individuals that purchase hardware from hardware manufacturers or hardware dealers and further process the hardware by integrating it in doors. Building element dealers or installation companies The “building element dealers or installation companies” target group includes all companies and individuals that purchase doors from door manufacturers for resale and installation in a construction project, without modifying the doors. Builders The “builders” target group includes all companies and individuals who place orders for the manufacture of doors for installation in their construction projects. End users The “end users” target group includes all individuals who use the installed doors. 8 · 05 / 2020 · IMO_502_EN_v2 Roto Safe - Cable junctions Subject to change.
General information Fabricator 1.8 Fabricator All installation work must be carried out by experts. Experts are persons who have sufficient knowledge in the area of cable junctions for doors due to their training and experience. Only an electrician may connect the frame component (mat. no. 817028) to the 230 V power supply. Experts are persons who are also sufficiently familiar with the relevant statutory occupational health and safety regulations, accident prevention regulations, directives and generally recognised rules of good engineering practice (e.g. VDE regulations, BGR guideline, DIN standards) to be able to evaluate whether cable junctions for doors are safe to operate. Adherence to the relevant local installation regulations and provisions is required for installation. 1.9 Target groups’ obligation to give instructions INFO Each target group must fulfil their obligation to give instructions in full. Unless specified otherwise in the text below, documents and information can be passed on as a printed document, on a data storage device or via the Internet. Responsibility of hardware dealers Hardware dealers must pass the following documents on to the door manufacturer: ■ Catalogue ■ Installation, maintenance and operation instructions Responsibility of the door manufacturer The door manufacturer must pass the following document on to building element dealers or the builder, even if a subcontractor (installation company) is involved: ■ Installation, maintenance and operation instructions They must ensure that the end users are provided with the documents and information intended for them in printed format. Responsibility of building element dealers / the installation company Building element dealers must pass the following document on to the builder, even if a subcontractor (installation company) is involved: ■ Maintenance and operation instructions Responsibility of the builder The builder must hand over the following document to the end user: ■ Maintenance and operation instructions Subject to change. Roto Safe - Cable junctions IMO_502_EN_v2 · 05 / 2020 · 9
General information Copyright protection 1.10 Copyright protection The contents of this document are copyright-protected. This content can be used when working with the hardware. Any other use is not permitted without written permission of the manufacturer. 1.11 Limitation of liability All information and instructions contained in this document have been compiled in consideration of the applicable standards and regulations, the latest developments in technology and many years of knowledge and experience. The hardware manufacturer assumes no liability for damage caused by: ■ Failure to comply with this document and all product-specific documents and other applicable directives (see the chapters entitled “Security” and “Stipulated use”). ■ Improper use / misuse (see the chapters entitled “Security” and “Stipu- lated use”). ■ Insufficient invitation to tender, non-compliance with installation specifi- cations and non-compliance with the application diagrams (where available). ■ Increased contamination. Claims made by third parties against the hardware manufacturer on account of damage resulting from misuse or failure to comply with the obligation to give instructions on the part of hardware dealers, window, door and balcony door manufacturers and building element dealers or the builder are passed on accordingly. The obligations agreed in the delivery contract, the general terms and condi- tions, the hardware manufacturer’s terms and conditions of delivery and the legal provisions applicable when the contract was concluded shall apply. The warranty only covers original Roto components. We reserve the right to make technical changes as part of improvement to performance characteristics and further development. 1.12 Preserving the surface finish ATTENTION Surface treatments may cause property damage. Surface treatments (e.g. painting and varnishing) on elements can damage components or prevent them from working properly. u For masking, only use adhesive tape that does not damage the paint coats. Consult the manufacturer if in doubt. u Protect components against direct contact with the surface treatment. u Protect components against contamination. 10 · 05 / 2020 · IMO_502_EN_v2 Roto Safe - Cable junctions Subject to change.
General information Preserving the surface finish ATTENTION Using incorrect cleaning agents and sealing compounds may cause property damage. Cleaning agents and sealing compounds may damage the surfaces of components and gaskets. u Do not use aggressive or flammable liquids, acidic cleaners or abrasive cleaners. u Only use mild, pH-neutral cleaning agents that have been diluted. u Apply a thin protective film to the components, for example using a cloth soaked in oil. u Avoid aggressive vapours (e.g. produced by formic acid, acetic acid, ammonia, amine compounds, ammonia compounds, aldehyde, carbolic acid, chlorine, tannic acid) around the element. u Do not use any acetic acid-crosslinking or acid-crosslinking sealing compounds or those with the aforementioned constit- uents as both direct contact with the sealing compound and its fumes can corrode the surface of the components. ATTENTION Contamination may cause property damage. Contamination prevents components working properly. u Remove deposits and contamination caused by construction materials (e.g. plaster, gypsum). u Keep components free of deposits and contaminants. ATTENTION (Permanently) damp room air may cause property damage. Damp room air can lead to mould growth and corrosion caused by condensation. u Provide adequate ventilation for components, particularly during the construction phase. u Intensively air out the room several times per day by opening all elements for approximately 15 minutes. If intensive airing is not an option, place the elements in the tilt position and provide airtight masking inside the room, e.g. if there is fresh screed that cannot be walked on or must not be exposed to draughts. Discharge any humidity present in the room air to the outside using condensation dryers. u Establish a ventilation plan for more complex construction projects if necessary. u Provide adequate ventilation during holiday periods as well. Subject to change. Roto Safe - Cable junctions IMO_502_EN_v2 · 05 / 2020 · 11
Security 2 Security This manual contains instructions relating to safety. The principal safety infor- mation in this chapter includes information and instructions relevant to the safe use or maintaining the safe condition of the product. Warning instruc- tions that relate to handling warn of residual risks and are located before steps that are relevant to safety. u Follow all of the instructions in order to prevent personal injury and property and environmental damage. 2.1 Presentation and structure of warning instructions The warning instructions relate to individual actions and are structured as follows with a warning symbol: DANGER Nature and source of the danger. Explanation and description of the danger and the implications. u Measures to take to avert the danger. 2.2 Security levels of warning instructions The warning instructions that relate to handling are identified differently according to the severity of the associated danger. The signal words and the associated warning symbols used are clarified below. DANGER Immediate risk of death or serious injuries. u Observe these warning instructions to avoid personal injuries. WARNING Potential risk of death or serious injuries. u Observe these warning instructions to avoid personal injuries. CAUTION Risk of injuries u Observe these warning instructions to avoid personal injuries. ATTENTION Reference to property or environmental damage. u Observe these warning instructions to avoid property or environmental damage. 2.3 Basic safety information The following hazards may arise when handling the product: 12 · 05 / 2020 · IMO_502_EN_v2 Roto Safe - Cable junctions Subject to change.
Security Basic safety information Installation 2.3.1 Installation Incorrect installation poses an immediate risk of death or serious injuries. Incorrect installation or assembly of hardware can lead to hazardous situa- tions or property damage. Depending on the height of the fall, this can result in serious to life-threatening injuries and glass breakage. u Only use hardware combinations that have been approved by the hardware manufacturer. u Only use original accessories or those that have been approved by the hardware manufacturer. u Always have installation performed by a specialist company. Heavy loads pose a risk of injury. Lifting and carrying heavy loads may lead to injuries in the event of a fall or physical overexertion. u Note the applicable accident prevention regulations. u Transport heavy loads with two people and use suitable transportation means (such as an industrial truck). Physical strain may cause damage to health. Moving heavy loads for extended periods leads to physical injury in the long term. u When carrying and lifting by hand, comply with a maximum weight of 25 kg for men and 10 kg for women. u Carry and lift even small loads with an ergonomically correct posture. 2.3.2 Use Falls from open windows and balcony doors present an immediate risk of death and pose the risk of serious injuries. Opened sashes of windows and balcony doors create a danger zone. Depending on the height of the fall, this can result in serious to life-threat- ening injuries and glass breakage. u Take care when in the vicinity of open windows and balcony doors. u Keep children and anyone unable to understand the risks away from the hazardous area. Trapping body parts in the opening between sash and frame may lead to serious injuries. Gripping between the sash and frame when closing windows and balcony doors poses the risk of crushing injuries. u When closing windows and balcony doors, never grip between the sash and frame and always exercise caution. Subject to change. Roto Safe - Cable junctions IMO_502_EN_v2 · 05 / 2020 · 13
Security Basic safety information Ambient conditions u Keep children and anyone unable to understand the risks away from the hazardous area. Opening and closing sashes improperly poses the risk of injury and property damage. Incorrect opening and closing of sashes can result in serious injuries and substantial property damage. u When moving the sash, ensure that it will not slam against the frame or other sashes once fully opened or closed. u Ensure that the sash is slowly guided by hand throughout its entire movement range, until it has been brought into a fully closed or opening position. u When closing a sash and locking the hardware, the gasket counter force must be overcome. Misuse poses a risk of injury and property damage. Misuse can lead to hazardous situations and may destroy the hardware, frame materials or other individual components within the windows or balcony doors. u Do not introduce any obstacles in the opening area between the frame and window or balcony door sashes. u Do not place additional loads on windows and balcony door sashes. u Refrain from intentionally or uncontrollably slamming or pushing the window or balcony door sash against the window reveal. Improper maintenance poses the potential risk of injury and property damage. Windows and balcony doors, including the hardware, require expert mainte- nance (care, cleaning, maintenance and inspection) in order to guarantee their proper condition and safe use. u Keep the hardware free of deposits and contaminants. u Carry out care and cleaning tasks as specified in these instructions. u Always have regular maintenance, adjustment and repair work carried out by a specialist company. 2.3.3 Ambient conditions Physical and chemical influences may result in property damage. Hardware components can be permanently damaged to the point that they can no longer function in a saline, aggressive or corrosive environment. u Do not use the hardware components in a saline, aggressive or corrosive environment. u Carry out care and cleaning tasks as specified in these instructions. u Corrosion protection must be inspected by an authorised specialist company as part of regular maintenance work. Moisture may cause property damage. Depending on the outside temperature, relative humidity of the room air and installation conditions for the windows and balcony doors, a temporary build- up of condensation may occur. This can lead to corrosion on the hardware and mould growth on the frame or wall. Ambient conditions that are too 14 · 05 / 2020 · IMO_502_EN_v2 Roto Safe - Cable junctions Subject to change.
Security Operation Stipulated use damp, particularly during the construction phase, can lead to timber elements warping. u Avoid preventing the circulation of air (e.g. due to deep reveals, curtains and unfavourable positioning of heaters or the like). u Intensively air out the room several times per day. Open all windows and balcony doors for approximately 15 minutes so that the air in the room can be completely replaced. u Provide adequate ventilation during holiday periods as well. u Create a ventilation plan for construction projects if necessary. 2.3.4 Stipulated use The cable junctions can be used for supplying power to electrical multipoint locking systems. The stipulated use also includes compliance with all information contained in the product-specific documentation, such as: ■ These installation, maintenance and operation instructions ■ Product catalogues ■ Information, specifications from profile manufacturers (e.g. light metal profiles, etc.) ■ Applicable national laws and directives. 2.3.4.1 Misuse Any use and processing of the products that goes beyond or differs from the stipulated use is considered misuse and can lead to hazardous situations. WARNING Misuse may pose a risk of death! Misuse and incorrect installation of hardware can lead to serious injuries. u Only use hardware combinations that have been approved by the hardware manufacturer. u Only use original accessories or those that have been approved by the hardware manufacturer. u Note the product-related documentation from page 6. 2.4 Operation The safety symbols and markings and the associated warning instructions explained below apply to the safe operation of windows and balcony doors. Safety symbols and markings Symbol Meaning Falls from open windows and balcony doors present an immediate risk of death and pose the risk of serious injuries. Take care when in the vicinity of open windows and balcony doors. Keep children and anyone unable to understand the risks away from the hazardous area. Subject to change. Roto Safe - Cable junctions IMO_502_EN_v2 · 05 / 2020 · 15
Security Operation Symbol Meaning Trapping body parts in the opening between sash and frame may lead to serious injuries. When closing windows and balcony doors, never grip between the sash and frame and always exercise caution. Keep children and anyone unable to understand the risks away from the hazardous area. Placing additional loads on the sash may lead to minor injuries and property damage. Avoid placing additional loads on the sash. The impact of wind may lead to minor injuries and property damage. Avoid exposing the open sash to wind. Close and lock the window and balcony door sash in windy or draughty conditions. Introducing obstacles into the opening between sash and frame may result in minor injuries and property damage. Avoid introducing obstacles into the opening between sash and frame. Pressing the sash against the edge of an opening (reveal) may pose a risk of minor injuries and cause property damage Refrain from pressing the sash against the edge of an opening (reveal). 16 · 05 / 2020 · IMO_502_EN_v2 Roto Safe - Cable junctions Subject to change.
Information on the product 3 Information on the product 3.1 Overview Frame side Frame component Description Mat. no. Properties ■ 6-pin, detachable plug connection 820187 ■ Connector side with 4 m cable ■ Can be used with timber, PVC and aluminium profiles ■ Moulded-on cable ■ Bracket available ■ Without power supply unit ■ The join between the frame and leaf has IP67 protection Scope of delivery ■ 1x cable junction Properties ■ 6-pin, detachable plug connection 817028 ■ Can be used with timber, PVC and aluminium profiles ■ Moulded-on cable ■ Built-in power supply unit ■ Connector side with 3 m cable for connection to 230 V ■ Plug & Play ■ Clamp strip for external access control systems ■ Voltage check by means of visible LED ■ Can be connected directly to 230 V power supply ■ Earthed cover ■ No ventilation slot required for timber ■ The join between the frame and leaf has IP67 protection Scope of delivery ■ 1x cable junction Subject to change. Roto Safe - Cable junctions IMO_502_EN_v2 · 05 / 2020 · 17
Information on the product Technical data Leaf side Leaf component Description Mat. no. Properties ■ 6-pin, detachable plug connection 820194 ■ Can be used with timber, PVC and aluminium profiles ■ Moulded-on cable ■ Can be used with a limited rebate clearance ■ Mounting casing with plate ■ 180° turn angle ■ The join between the leaf and frame has IP67 protection ■ Bush side with spiral fitted to mounting casing (installation in U-shape) Scope of delivery ■ 1x cable junction ■ 1x set of screws Required acces- Cable – type E 633291 sories Cable – type EZ 633292 Properties ■ 6-pin, detachable plug connection 820255 ■ Can be used with timber, PVC and aluminium profiles ■ Moulded-on cable ■ 180° turn angle ■ The join between the leaf and frame has IP67 protection ■ Bush side with spiral for lengthways instal- lation ■ Pre-assembled cable with connectors for joining the cable junction, the Eneo multipoint locking system and the access control system, length of 0.3 m and 3 m ■ Including cover plate Scope of delivery ■ 1x cable junction ■ 1x set of screws ■ 1x cover plate 3.2 Technical data Technical data for power supply unit Cable junction 817028 Cable H03VV-F 3x1.5 mm2 Input 230 V AC; 50 - 60 Hz Output 24 V DC; 2.5 A DC Degree of protection in accordance with DIN 40050 IP67 (when inserted and only the plug connection between leaf and frame) Temperature range When idle: -10 °C to +70 °C When moving: -10 °C to +50 °C Standards CE conformity 18 · 05 / 2020 · IMO_502_EN_v2 Roto Safe - Cable junctions Subject to change.
Information on the product Bush and connector 3.3 Bush and connector Schematic diagram of bush Cable: LIF9Y11Y, 6 x 0.34 mm2 Schematic diagram of connector Cable: LIF9Y11Y, 6 x 0.34 mm2 Subject to change. Roto Safe - Cable junctions IMO_502_EN_v2 · 05 / 2020 · 19
Information on the product Overview of variants 3.4 Overview of variants Variant 1 – rebate clearance 12 / 16 mm Mat. no. 820187 Mat. no. 820255 Installation situation [1] Frame component [2] Leaf component 3 [3] Cover plate ( from page 45) 1 2 20 · 05 / 2020 · IMO_502_EN_v2 Roto Safe - Cable junctions Subject to change.
Information on the product Overview of variants Variant 2 – rebate clearance 4 / 12 mm Mat. no. 820187 Mat. no. 820194 Installation situation [1] Frame component 4 [2] Leaf component [3] Retaining bracket ( from page 44) [4] Cover plate ( from page 45) 1 2 3 Subject to change. Roto Safe - Cable junctions IMO_502_EN_v2 · 05 / 2020 · 21
Information on the product Overview of variants Variant 3 – rebate clearance 12 / 16 mm Mat. no. 817028 Mat. no. 820255 Installation situation [1] Frame component 1 [2] Leaf component 2 22 · 05 / 2020 · IMO_502_EN_v2 Roto Safe - Cable junctions Subject to change.
Information on the product Overview of variants Variant 4 – rebate clearance 4 / 12 mm Mat. no. 817028 Mat. no. 820194 Installation situation 2 [1] Frame component [2] Leaf component [3] Retaining bracket ( from page 44) 3 1 Subject to change. Roto Safe - Cable junctions IMO_502_EN_v2 · 05 / 2020 · 23
Installation 4 Installation 4.1 Processing instructions ■ Due to the large number of profiles and hardware variants on the market, it is not possible to make any generally applicable statements about installation, because some of the dimensions of these systems differ. ■ Before starting installation, inspect the installation location and the available space in the rebate area. ■ Installation location: door frame or door rebate ■ Prevent torsion (twisting of the cable) along the entire length of the cable, specifically in the metal spring. ■ Drill holes for routing the cable Ø 16. Deburr the drill holes and remove swarf. ■ In addition to the generally applicable rules of good engineering practice, the following technical regulations must be complied with, in particular: VDS 2311, VDE 0100. 4.2 Dimensions Frame components Frame side without power supply unit Ø 4.9 8.5 Ø3 .2 57.5 43 10.4 24 · 05 / 2020 · IMO_502_EN_v2 Roto Safe - Cable junctions Subject to change.
Installation Dimensions Frame side with power supply unit Ø5 19.4 43 100.2 10 376 400 206.2 180 3 24 41.6 Sash components Sash side without casing (lengthways installation) Ø3 .2 Ø 4.9 126 110 11.8 62 3 10 16 Subject to change. Roto Safe - Cable junctions IMO_502_EN_v2 · 05 / 2020 · 25
Installation Drilling and routing dimensions Sash side with casing (U-shape) 230 210 1 25 20 45 4.3 Drilling and routing dimensions INFO The drill holes must be free from burr and swarf. INFO Only tighten screws by hand. Recommendation: predrill screw holes. Frame component without power supply unit + leaf component without casing 10 1 12.5 35 238 5.5 [1] Routing depth: 30 mm 26 · 05 / 2020 · IMO_502_EN_v2 Roto Safe - Cable junctions Subject to change.
Installation Drilling and routing dimensions Frame component without power supply unit + leaf component with casing 29 12.5 210 194 1 230 2 20 [1] Routing depth: 60 mm [2] Routing depth: 1 mm Frame component with power supply unit + leaf component without casing 10 3 35 400 2 291 350 1 376 5.5 24 [1] Routing depth: 42 mm [2] Routing depth: 3 mm [3] Routing depth: 30 mm Subject to change. Roto Safe - Cable junctions IMO_502_EN_v2 · 05 / 2020 · 27
Installation Installation Frame component with power supply unit + leaf component with casing 0 400 2 210 194 3 230 4 350 1 376 24 20 [1] Routing depth: 42 mm [2] Routing depth: 3 mm [3] Routing depth: 60 mm [4] Routing depth: 1 mm 4.4 Installation 1. Carry out the routing and drilling work from page 26. INFO Only tighten screws by hand. Predrilling the screw holes is recom- mended. 2. Route the cable [1] through the leaf or frame. Lay a cable loop, ensuring that there is enough spare cable. INFO Do not crush or damage the cable when installing the frame. 3. Secure the mounting casing with screws [2]. 28 · 05 / 2020 · IMO_502_EN_v2 Roto Safe - Cable junctions Subject to change.
Installation Installation Leaf side 1 2 1 2 Frame side 1 2 Subject to change. Roto Safe - Cable junctions IMO_502_EN_v2 · 05 / 2020 · 29
Installation Installation 1 2 4. Secure the connector side with a screw. 5. Hinge the leaf and establish the plug connection. ATTENTION A short-circuit may cause property damage. Chips in the connector or bush may cause a short-circuit. u Keep the bush and connector clean. INFO Note the anti-twist protection of the plug connection. 30 · 05 / 2020 · IMO_502_EN_v2 Roto Safe - Cable junctions Subject to change.
Installation Installation 6. Secure the plug connection with a screw [3]. 3 7. Check that the cable junction is working properly from page 35. INFO Do not exceed the technical values (voltage, current, power). INFO Only an electrician may connect the frame component with built-in power supply unit (mat. no. 817028) to the 230 V power supply. DANGER Risk of death caused by electric shock! Current can lead to fatal injuries. u Take extra care when handling live components. u Only an electrician may connect the power supply unit to the mains voltage. u Observe and comply with the respective national regulations (in Germany VDE 0100 and others). Subject to change. Roto Safe - Cable junctions IMO_502_EN_v2 · 05 / 2020 · 31
Connection diagram 5 Connection diagram The following diagrams are non-binding application examples. These are only intended to provide guidance for customers and do not represent customer-specific solutions. Proper operation is the responsibility of the customer. The customer is obligated to ensure safe installation, use, maintenance and operation. The customer is furthermore obligated to ensure that the equipment is only installed by a qualified electrician; failure to do so may result in a risk of fire or risk of electric shock. Compliance with the applicable standards and provisions must be ensured at all times; the installation company of the system bears full responsibility for this. The system may not be operated if compliance with the applicable standards and provisions cannot be ensured. No guarantee is given for the application examples provided. Roto Frank Fenster- und Türtechnologie GmbH shall assume no liability for damage caused by use of the application examples, unless we are obligated to bear liability in accordance with legal provisions in cases of wilful intent. Other connection diagrams: IMO_310 INFO Installation and maintenance work may only be carried out by a company specialising in electrical systems. There is a risk of death when using a mains voltage of 230 V (or 115 V). Only carry out work when the power supply is disconnected. INFO For a cable junction with built-in power supply unit, external components are clamped directly on to the cable junction on the frame. The cable junction must be removed so that you can do this. To connect external components, connect a 6 x 0.34 mm2 cable to the cable junction and route it outwards. Terminal assignment of cable junction with built-in power supply unit: Terminal 1 IN1 / input 1 (OPEN) Terminal 2 +24 V Terminal 3 GND Terminal 4 IN2 / input 2 Terminal 5 K1a pot.-free contact Terminal 6 K1b pot.-free contact INFO Terminals 5 and 6 are connected to one another internally via a relay and a 47 ohm resistor. The maximum load of the contacts is 24 V / 40 mA. The following basic circuits are used as examples. 32 · 05 / 2020 · IMO_502_EN_v2 Roto Safe - Cable junctions Subject to change.
Connection diagram Eneo A / AF with Phone & Code, power supply unit in general 5.1 Eneo A / AF with Phone & Code, power supply unit in general Eneo A / AF +24 V GND IN1 black green unassigned unassigned unassigned JST plug connection Outside Connector / cable assignment brown green white white: IN1 / input 1 (OPEN) brown: +24 V white brown green: GND brown green Black Box White yellow: IN2 / input 2 green white grey: unassigned pink: unassigned Phone & Code cable assignment Access (between JST connector and Black Box) control white: +24 V system brown: GND green: control (OPEN) Phone & Code EZ cable 3m brown yellow green white grey pink Sash side 1 2 3 4 5 6 plug-in cable junction Frame side 1 2 3 4 5 6 +24 V GND INFO brown white red black The 24 V side must not be wired. Inside Push-button black red Video system brown +24 V GND brown Power supply unit white white IN: potential-free contact 100-230 V AC Inside: OUT: The “Unlock door” push-button 24 V DC can be used as an option. Intercom 230 V AC Cable, 3 m brown Signal (e.g. 12 V) white potential-free contact Subject to change. Roto Safe - Cable junctions IMO_502_EN_v2 · 05 / 2020 · 33
Connection diagram Eneo C / CC / CF with Phone & Code, power supply unit in general 5.2 Eneo C / CC / CF with Phone & Code, power supply unit in general Eneo C / CC / CF +24 V GND K1b K1a IN2 IN1 Black Green Switch JST plug connection “Day / night” Brown Green White Grey Outside Pink Yellow White Brown Green Green Black Box Brown White Green White Brown Inside: Access Phone & Code cable assignment can be used control (between JST connector and Black Box) as an option. system White: +24 V Brown: GND EZ cable, Phone & 3m Green: control (OPEN) Code Connector / cable assignment White: IN1 / input 1 (OPEN) Brown: +24 V Green: GND Yellow: IN2 / input 2 Outside: Grey: K1a pot.-free contact “Unlock door” Pink: K1b pot.-free contact Brown Yellow Green White access control system Grey Pink Leaf side 1 2 3 4 5 6 Plug-in cable junction Frame side 1 2 3 4 5 6 +24 V GND INFO Black Red White Brown The 24 V side must not be wired. Inside Black Push-button Red Video system Brown +24 V GND Brown Power supply unit IN: White 100-230 V AC White OUT: Potential-free contact 24 V DC Inside: “Unlock door” push-button, optional for Eneo CC. 230 V AC Intercom Cable, 3 m INFO! Brown Signal (e.g. 12 V) The yellow wire must remain unassigned; otherwise this will bridge the switch on the leaf. Terminals 5 and 6 are connected to one another internally via White a relay and a 47 ohm resistor. The maximum load of the contacts Potential-free contact is 24 V / 40 mA 34 · 05 / 2020 · IMO_502_EN_v2 Roto Safe - Cable junctions Subject to change.
Operation 6 Operation 6.1 Fault assistance Fault Cause Corrective action To be carried out by No power supply. Loose plug connection. Plug in the connector so that it is secure. ■ Check the power supply (LED must be lit). Cable breakage. Replace the cable. ■ No power connection. Check the plug connections. ■ Check the power supply (LED must be lit). Check the power supply unit. ■ = Must be carried out by a specialist company 6.2 Performance test 1. Check the power supply at the power supply unit. LED is lit up green when there is voltage. 2. When the door is installed, test the electrical multipoint locking system and any access control systems that are fitted. Subject to change. Roto Safe - Cable junctions IMO_502_EN_v2 · 05 / 2020 · 35
Maintenance 7 Maintenance CAUTION Performing maintenance work incorrectly can lead to injuries. Performing maintenance incorrectly can lead to injuries. u Ensure that there is sufficient space for installation before starting work. u Ensure that the installation site is clean and tidy. u Always have hardware adjustment and replacement work performed by a specialist company. u Secure the sash against unintentionally opening or closing. u Do not unhinge the sash for maintenance. ATTENTION Incorrect or improper testing may cause property damage. Incorrect or improper testing of the hardware may cause the element to malfunction. u Have the hardware checked by a specialist company when installed. u If defects need to be remedied, have the element unhinged and remounted by a specialist company. INFO The manufacturer must draw the attention of builders and end consumers to these maintenance instruc- tions. Roto Frank Fenster- und Türtechnologie GmbH recommends the manufacturer conclude a maintenance agreement with their end users. No legal claims can be derived from the following recommendations; their application is to be based on the specific individual case. Responsibility Maintenance interval □ from page 37 Cleaning from page 37 Clean hardware □ Care Lubricate movable parts □ Lubricate locking points □ Performance test from page 37 Check that hardware components are fitted securely □ Inspect hardware components for wear □ Check that movable parts work properly □ Check that locking points work properly □ Check ease of movement ■ Repair from page 39 Retighten screws ■ Replace damaged components ■ □ = May be carried out by a specialist company or the end user ■ = Must be carried out by a specialist company 36 · 05 / 2020 · IMO_502_EN_v2 Roto Safe - Cable junctions Subject to change.
Maintenance Maintenance intervals 7.1 Maintenance intervals ATTENTION Failure to adhere to maintenance intervals may cause property damage. The maintenance interval for all tasks relating to the hardware components is annually at the least. In hospitals, schools and hotels, the maintenance interval is six-monthly. Regular maintenance is necessary in order to maintain the proper and smooth-running operation of the hardware and to prevent premature wear or even defects. u Determine and adhere to the appropriate maintenance interval in accordance with the ambient condi- tions. 7.2 Cleaning ATTENTION Using incorrect cleaning agents and sealing compounds may cause property damage. Cleaning agents and sealing compounds may damage the surfaces of components and gaskets. u Do not use aggressive or flammable liquids, acidic cleaners or abrasive cleaners. u Only use mild, pH-neutral cleaning agents that have been diluted. u Apply a thin protective film to the components, for example using a cloth soaked in oil. u Avoid aggressive vapours (e.g. produced by formic acid, acetic acid, ammonia, amine compounds, ammonia compounds, aldehyde, carbolic acid, chlorine, tannic acid) around the element. u Do not use any acetic acid-crosslinking or acid-crosslinking sealing compounds or those with the aforementioned constituents as both direct contact with the sealing compound and its fumes can corrode the surface of the components. Cleaning the hardware u Clean deposits and contaminants off the hardware using a soft cloth. u Lubricate movable parts and locking points after cleaning. u Apply a thin protective film to the hardware, for example using a cloth soaked in oil. 7.3 Performance test PRECONDITION The sash and frame must be vertical for the performance test. When the door is open Fixing screws ATTENTION Over-tightened screws may cause property damage. Over-tightened screws lose their hold and no longer provide the necessary strength. u Do not over-tighten screws. Note the torque. Use a screwdriver to check that all fixing screws have been tightened. Door lever handle function Push the door lever handle all the way down and release. u The door lever handle must automatically return to the initial position. Subject to change. Roto Safe - Cable junctions IMO_502_EN_v2 · 05 / 2020 · 37
Maintenance Performance test Latch function 1. Push the door lever handle all the way down. u The latch must retract. u When pushed down, the latch may protrude over the lock faceplate by a maximum of 2 mm. 2. Release the door lever handle. u The latch must extend fully. 3. Turn the key in the profile cylinder in the unlocking direction. u The latch must retract fully. 4. Turn the key in the profile cylinder in the locking direction. u The latch must extend fully. Deadbolt function Insert the key into the profile cylinder and turn in the locking direction: Push-back safeguard: turn once Locking: turn twice u The deadbolt must be extended fully (11 mm or 20 mm). u All additional locking points must be in the locking position. u It must be possible to remove the key. Have malfunctions remedied by a specialist company. When the door is closed Locking process Close the door. u The latch must run into the frame component and keep the door closed. Opening using the door lever handle With the door closed, push the door lever handle all the way down. u The latch must retract fully so that the door can be opened. Locking using the key With the door closed, turn the key in the locking direction. u The key must be easy to turn. u The latch and all deadbolts must run smoothly and extend fully. Unlocking using the key With the door locked, turn the key in the unlocking direction. u The key must be easy to turn. u The latch and all deadbolts must retract fully. 38 · 05 / 2020 · IMO_502_EN_v2 Roto Safe - Cable junctions Subject to change.
Maintenance Repair Have malfunctions remedied by a specialist company. 7.4 Repair WARNING Improper repair work may pose a risk of death! Improper maintenance may prevent the element from working properly and make it less safe to use. u Always have repairs performed by a specialist company. ATTENTION Improper screw fixings may cause property damage. Loose or faulty screws can prevent the hardware from working properly. u Check that the individual screws are secure and seated correctly. u Tighten or replace loose or faulty screws. u Use only the suggested screws. Repair work includes replacing and repairing components and is only necessary if components have become damaged after wear or as a result of external circumstances. The hardware must be secured reliably in order to ensure that the element works properly and is safe to use. The following tasks must only be performed by a specialist company: ■ All adjustment work on the hardware, ■ Replacing hardware or hardware components, ■ Installing and removing windows, doors or balcony doors The specialist company must observe the following: ■ Perform the necessary repair work properly, according to generally recognised engineering practice and in accordance with the applicable regulations. ■ Do not perform makeshift repairs on worn or damaged components. ■ Only use original or approved spare parts for repairs. Subject to change. Roto Safe - Cable junctions IMO_502_EN_v2 · 05 / 2020 · 39
Dismantling 8 Dismantling WARNING Improper dismantling may pose a risk of death! The sash may fall during dismantling. u Secure the sash to prevent it from falling, e.g. by using two people. u Always have dismantling work performed by a specialist company. CAUTION Physical strain may cause injury and damage to health. Carrying and lifting heavy loads for extended periods leads to physical injury in the long term. u When carrying or lifting loads, maintain an ergonomically correct posture. The maximum permissible load is 25 kg for men and 10 kg for women. INFO Unless otherwise stated, dismantling is performed in reverse order to installation. 8.1 Dismantling 1. Stop the power supply. Pull out the connector. 2. Undo and remove the screw. 3. Undo the plug connection with a hex key or suitable screwdriver. ATTENTION A faulty spring may cause property damage. Undoing the plug connection in an uncontrolled manner may damage the spring. u Do not pull on the spring to undo the plug connection. u Use a hex key or suitable screwdriver to undo the plug connection. 4. Unhinge the sash. 5. Protect the plug connection against dust and moisture. 40 · 05 / 2020 · IMO_502_EN_v2 Roto Safe - Cable junctions Subject to change.
Transport 9 Transport 9.1 Transporting elements and hardware DANGER Improper transport poses a risk of death! Improper procedures for transporting, loading or unloading elements may cause serious injuries and glass breakage as a result of the elements swinging open, falling or becoming overloaded. u Note the applicable accident prevention regulations. u Note force application points and reaction forces. u Prevent the sash from opening uncontrollably. u Avoid jerky movements. u Use suitable transportation means and protective devices. u Watch out for protruding components. u Transport heavy loads with two people and use suitable trans- portation means (such as an industrial truck). CAUTION Trapped limbs may result in injuries. The transported goods can skid, open, close or fall during trans- portation tasks. This can result in limbs being trapped and seriously injured. u Never reach near the scissor stays. u Close the sash after installation and secure it in place for transport. u Wear safety gloves and protective footwear. CAUTION Physical strain may cause injury and damage to health. Carrying and lifting heavy loads for extended periods leads to physical injury in the long term. u When carrying or lifting loads, maintain an ergonomically correct posture. The maximum permissible load is 25 kg for men and 10 kg for women. Hardware is supplied to the specialist company as complete sets. The components are packaged accordingly for each shipment. The instructions for safely transporting the hardware are described below. Observe the following basic instructions when transporting hardware: u Transport larger scopes of delivery using appropriate transportation means (such as industrial trucks). u Note the transport weight in order to select appropriate transportation means. u Immediately check the delivery for completeness and transport damage on receipt. INFO Submit a complaint about any defects as soon as they are identified. Claims for damages may only be made within the reclamation period. Use the following transportation means for support when transporting, loading and unloading larger scopes of delivery: ■ Industrial trucks, e.g. forklifts, telescopic handlers, pallet trucks Subject to change. Roto Safe - Cable junctions IMO_502_EN_v2 · 05 / 2020 · 41
Transport Storing the hardware ■ Lifting equipment, e.g. transport nets, carry straps, round slings ■ Protective devices, e.g. edge protection, spacer blocks INFO Industrial trucks and lifting devices may only be operated by qualified persons. INFO Lifting equipment and protective devices may only be used if they are in full working order. 9.2 Storing the hardware Store all hardware components as follows until they are installed: ■ Dry and protected ■ On a level surface ■ Protected against sunlight 9.3 Transport inspection Immediately check the delivery for completeness and transport damage on receipt. ATTENTION Strong vibration may cause property damage. Strong vibration can permanently damage the magnet and contact element. u Avoid vibration during transport. 42 · 05 / 2020 · IMO_502_EN_v2 Roto Safe - Cable junctions Subject to change.
You can also read