CALSYS -196/-80 Portable RTD Calibrator for Industrial/ Dry Block Calibrators Laboratory Field Use Wide Temperature Range CALsys -196/-80 offer a wide temperature range from -190 °C to -80 °C Lightweight, portable The CALsys -196/-80 block is ideal for Industrial/ Laboratory field use. It only weights about 8 kg, and it is small enough to carry around. Accuracy and performance The CALsys -196/-80 is an easily portable unit that also provides excellent calibration accuracy with stability ± 0.1°C at -190 °C. Accredited calibration Each CALsys -196/-80 is delivered with an CALsys -196/-80 offers ultra low temperature range from -190 to -80°C. accredited calibration certificate. It is a highly stable standard source for calibrating Thermocouples / RTD. It has been designed for low temperature range calibration and find Computer Interface application in the glass, pharma, electrical power, automotive & The communication port(RS-232/ USB) material processing industries. The comparison volume is a metallic enables communication with selected CALsys block of aluminium having dimension 25mm diameter with 300 mm -196/-80 calibrators for automation long which fixed into the liquid nitrogen container for calibration of RTD calibration and documentation thus it made documentation easy. & thermocouple. The temperature of the calibrator is set and controlled by a self tuned PID controller with automatic super fine adjustment. With the Tempsens make Compact Temperature Calibrator, you have chosen an extremely effective instrument which we hope will live up to all your expectations. This is a fast, timesaving, and reliable true industrial temperature calibrator designed for on-site use. During the past several years, we have acquired extensive knowledge of industrial temperature calibration. This expertise is reflected in our products which are all designed for daily use in an industrial environment.
SPECIFICATIONS Temperature range -190 to -80°C Temperature Resolution 1.0°C ±0.1°C at-190°C Stability ±0.1°C at -130°C ±0.1°C at -80 ±0.2°C at-190°C Uniformity ±0.15°C at -130°C ±0.17°C at -80 Controlling Sensor RTD Pt100 Method of Control Digital self tuned PID Controller Dia 25 x 300 mm long (2 x 6 mm & 2 x 8 mm holes) of 300 Insert Construction mm insertion depth Time to Reach Max Temp 30 Mins Computer Interface RS - 232 Operating Temperature 20 to 45°C Power Requirement 230 VAC, 300 W Dimensions of Container 580(H) x 280(Dia) Nitrogen Container 10Ltr. Dimension of Control Panel 270(H)x380(W)x270(D) Weight 15Kg (without packing) ACCESSORIES STANDARD ACCESSORIES KEY FEATURE Ÿ Reference Standard RTD Ÿ Large Immersion Depths Ÿ Wide Operating Range (-190 to -80°C) Ÿ High Stability Ÿ PC interfacing Ÿ Simple to use and cost effective Ÿ NABL accredited calibration certificate - 3 point Ÿ Separate control box Ÿ Software - Cal Soft including for setting bath temperature and monitoring the PV. Graphical OPTIONAL ACCESSORIES representations of PV/TIME with 2 hours data Ÿ TEMPMET 08, TEMPMET 09 logging. Ÿ Extra Equalizing Block………Part No. EQ2 Ÿ Operational Manual Tempsens Instruments (l) Pvt. Ltd. U# ll A-190, Road No.5, M.I.A., Udaipur-313003 (Rajasthan) INDIA Ph.:+91-294-3500629, Fax.:+91-294-3500631 Email: calsys@tempsens.com, info@tempsens.com
Calsys -100/40 Portable, Lightweight, highly accurate low temperature FPSC system based Calibrator for Industrial/ Laboratory Dry Block Calibrators field use Wide Temperature Range Calsys -100/40 offer a wide temperature range from -100°C to 40°C Lightweight, portable The Calsys -100/40 block is ideal for Industrial/ Laboratory field use. It only weights about 11 kg, and it is small enough to carry around. Speed The Calsys -100/40 extremely quick to reach various temperatures, i.e. it cools down to -100°C in 90 minutes and heats up room temp to +40°C in 20 minutes. This saves time and increases productivity. Accuracy and performance Calsys -100/40 offers easy to use portable low temperature calibrator with temperature range from -100 to 40°C. It is a highly stable standard The Calsys -100/40 is an easily portable unit that also provides excellent calibration furnace for calibrating RTD. This calibrator can be used on site for high accuracy with stability ± 0.05°C . temperature calibration and also find application in aerospace, oil gas petrochemical, pharmaceutical industry, electric power, automotive Cooling Technology and material process industry. The comparison volume is a metallic Tempsens provide low temperature dry block fixed block of special material, which has a fixed insert with 120mm calibrator with use of FPSC system. long. Low temperature dry block furnace based on FPSC cooling system. FPSC system able to cool down calibration block This model provides special design isothermal enclosure which can upto -100°C with minimum power. calibrate sensor against the calibrator. Temperature of the calibrator is Accredited calibration set and controlled by a self tuned PID controller with automatic super Each Calsys -100/40 is delivered with an fine adjustment. Our newly designed Calsys -100/40 model offers accredited calibration certificate. better esthetic design and performance wise upgraded to next level. With the Tempsens make Compact Temperature Calibrator, you have Computer Interface chosen an extremely effective instrument which we hope will live up to The communication port (RS-232/ USB) all your expectations. enables communication with selected Calsys - 100/40 calibrators for automation calibration During the past several years, we have acquired extensive knowledge of and documentation thus it made documentation easy. industrial temperature calibration. This expertise is reflected in our products which are all designed for daily use in an industrial environment.
SPECIFICATIONS Temperature range -100°C to 40°C (at 20°C) ±0.05°C at -100°C Stability ±0.03°C at 0°C ±0.05°C at 40°C Radial uniformity ±0.1°C at -80°C Immersion depth 120 mm Fixed insert dimensions 6.5 mm x 3 holes Method of Control Self tunned PID controller Cooling time 90 Min ( Ambient to -100°C) Resolution 0.1 °C Display LCD, °C or °F user-selectable Size (H x W x D) 380(H) x 170(W) x 188(D) mm Weight 11Kg Power requirements 230 VAC, 500W(50 Hz) Computer interface RS - 232 Calibration Accredited calibration certificate provided Environmental operating conditions 5 °C to 20 °C, 0 % to 90 % RH (non-condensing) Specifications valid in environmental 5°C … 20°C conditions Note : Customized options available as per customer requirement.
ACCESSORIES Inserts for Calsys -100/40 models Inserts for Calsys -100/40 are made of aluminum. All specifications on hole size based on outer diameter of the sensor under test. We also offer customized hole size based on Customer requirements. Insert Model Description Inserts Description Ci1 Multihole fixed, 1x8 mm, 2x 6.5mm SOFTWARE Ÿ CalSoft including for setting bath temperature and monitoring the PV. Graphical representations of PV/TIME with 2 hours data logging. MASTER SENSOR CARRY CASE Ÿ Reference Standard RTD Part no. TPRT- A- 300. Ÿ NABL accredited calibration certificate - 3 point Ÿ Tempsens makes customized carry case is a rugged, safe perfectly designed to carry our Ÿ Operational Manual new CALsys -100/40 calibrator and different accessories. Tempsens Instruments (l) Pvt. Ltd. U# ll A-190, Road No.5, M.I.A., Udaipur-313003 (Rajasthan) INDIA Ph.:+91-294-3500629, Fax.:+91-294-3500631 Email: calsys@tempsens.com, info@tempsens.com
CALSYS -30/110 CALsys -30/110 Autocal Highly accurate & Automatic Dry Block Calibrator for Dry Block Calibrators Industrial/Laboratory field use Wide Temperature Range Calsys -30/110 & CALsys -30/110 Autocal a wide temperature range from -30 °C to 110 °C Lightweight, portable The Calsys -30/110 & CALsys -30/110 Autocal block is ideal for Industrial/ Laboratory eld use.It only weights about 11 kg, and it is small enough to carry around. Speed The Calsys -30/110 & CALsys -30/110 Autocal extremely quick to reach various temp. , i.e. it cools down to 110 °C in 25 minutes and heats up room temp to +110 °C in 10 minutes. This saves time and increases productivity. Calsys -30/110 & CALsys -30/110 Autocal easy to use portable low temperature calibrator with temperature range from -30 to 110°C. It is a Accuracy and performance highly stable standard furnace for calibra ng RTD. This calibrator can be The Calsys -30/110 & CALsys -30/110 Autocal used on site for high temperature calibra on and also nd applica on in is an easily portable unit that also provides aerospace, oil gas petrochemical, pharmaceu cal industry, electric excellent calibration accuracy with stability ± power, automo ve and material process industry. The comparison 0.07 °C at 110 °C.. volume is a metallic fixed block of special material, which has a diameter of 32mm and 120mm long. Low temperature dry block furnace based on thermoelectric cooling circuitry. This model provides Accredited calibration special design isothermal enclosure which can calibrate sensor against The Calsys -30/110 & CALsys -30/110 Autocal the calibrator. Temperature of the calibrator is set and controlled by a is delivered with an accredited calibration self tuned PID controller with automa c super ne adjustment. Our certicate. newly designed Calsys -30/110 model offers be er esthe c design and performance wise upgraded to next level. The CALsys -30/110 Autocal is an automa c temperature calibra on system for the Thermocouple Computer Interface and RTD's. The system consists of Temperature bath and PC so ware, The communication port (RS-232/ USB) which together contribute to the whole cycle of auto calibra on enables communication with selected Calsys process. The system accept 4 channels, 4 Thermocouples or 4 RTD's. - 3 0 / 1 0 0 C a l i b rat i o n fo r a u to m at i o n The connec on for these channels through special type of locking calibration and documentation easy. connectors. The channel configura on can be done with LCD display via touch screen keypad. The thermocouple microvolt & RTD ohm reading for each channel is monitored with CJC compensa on. A er the calibra on process complete the PC so ware generates a report of actual calibrated values for the inputs. With the Tempsens make Compact Temperature Calibrator, you have chosen an extremely effec ve instrument which we hope will live up to all your expecta ons. This is a fast, mesaving, and reliable true industrial temperature calibrator designed for on-site use.
specifications Tempsens Instruments (l) Pvt. Ltd. U# ll A-190, Road No.5, M.I.A., Udaipur-313003 (Rajasthan) INDIA Ph.:+91-294-3500629, Fax.:+91-294-3500631 Email: calsys@tempsens.com, info@tempsens.com
Calsys -15/110 Portable, Lightweight, highly accurate low temperature Dry Block Calibrators Calibrator for Industrial/ Laboratory field use Wide Temperature Range Calsys -15/110 offer a wide temperature range from -15 °C to 110 °C Lightweight, portable The Calsys -15/110 block is ideal for Industrial/ Laboratory field use. It only weights about 11 kg, and it is small enough to carry around Speed The Calsys -15/110 extremely quick to reach various temperatures, i.e. it Heats down to - 15 °C in 25 minutes and heats up room temp to +110 °C in 10 minutes. This saves time and increases productivity Calsys -15/110 offers easy to use portable low temperature calibrator Accuracy and performance with temperature range from –15 to 110°C. It is a highly stable standard The Calsys -15/110 is an easily portable unit furnace for calibrating RTD. This calibrator can be used on site for high that also provides excellent calibration temperature calibration and also find application in aerospace, oil gas accuracy with stability ±0.07 °C at 110°C. petrochemical, pharmaceutical industry, electric power, automotive and material process industry. The comparison volume is a metallic Accredited calibration block of special material, which has a diameter of 24mm and 120mm Each Calsys -15/110 is delivered with an long. Low temperature dry block furnace based on thermoelectric accredited calibration certificate. cooling circuitry. This model provides special design isothermal enclosure which can calibrate sensor against the calibrator. Computer Interface Temperature of the calibrator is set and controlled by a self tuned PID The communication port(RS-232/USB) controller with automatic super fine adjustment. Our newly designed enables communication with selected Calsys Calsys -15/110 model offers better esthetic design and performance - 1 5 / 1 1 0 ca l i b rato rs fo r a u to m at i o n wise upgraded to next level. calibration and documentation thus it made documentation easy. With the Tempsens make Compact Temperature Calibrator, you have chosen an extremely effective instrument which we hope will live up to all your expectations. This is a fast, timesaving, and reliable true industrial temperature calibrator designed for on-site use. During the past several years, we have acquired extensive knowledge of industrial temperature calibration. This expertise is reflected in our products which are all designed for daily use in an industrial environment.
SPECIFICATIONS Temperature range at 25°c -15 °C to 110 °C Accuracy ±0.5 °C ±0.03°C at -15°C Stability ±0.05°C at 0°C ±0.07°C at 110°C ±0.05°C at -15°C Radial uniformity ±0.07°C at 0°C ±0.09°C at 110°C Hysteresis 0.02 °C Immersion depth 120 mm Insert OD dimensions 24 mm Method of Control Self tunned PID controller Heating time 10 Min Cooling time 25 Min ( 110 °C to -15°C) Resolution 0.1 °C Display LCD, °C or °F user-selectable Size (H x W x D) 380(H) x 170(W) x 188(D) mm Weight 11Kg Power requirements 230 VAC, 500 W(50 Hz) Computer interface RS - 232 Calibration Accredited calibration certificate provided Environmental operating conditions 5 °C to 25 °C, 0 % to 90 % RH (non-condensing) Specifications valid in environmental 5°C … 25°C conditions STABILITY / UNIFORMITY CALsys -15/110 0.1 Temperature in °C 0.08 0.06 0.04 0.02 0 -15 0 110 Temperature in °C STABILITY UNIFORMITY
ACCESSORIES Inserts for Calsys -15/110 models Inserts for Calsys -15/110 are made of aluminum. All specifications on hole size based on outer diameter of the sensor under test. We also offer customized hole size based on Customer requirements. Inserts Description Ci1 Multihole, 4 x 6.5 mm Ci2 Special (Customized) Customized Equalizing Block....Part No. EQ1 SOFTWARE Ÿ CalSoft including for setting bath temperature and monitoring the PV. Graphical representations of PV/TIME with 2 hours data logging. MASTER SENSOR CARRY CASE Ÿ Reference Standard RTD Part no. TPRT- A- 300. Ÿ NABL accredited calibration certificate - 3 point Ÿ Tempsens makes customized carry case is a rugged, safe perfectly designed to carry our Ÿ Operational Manual new CALsys -15/110 calibrator and different accessories. Tempsens Instruments (l) Pvt. Ltd. U# ll A-190, Road No.5, M.I.A., Udaipur-313003 (Rajasthan) INDIA Ph.:+91-294-3500629, Fax.:+91-294-3500631 Email: calsys@tempsens.com, info@tempsens.com
CALsys 120SP Peltier Based Temperature Calibrator for Industrial/ Dry Block Calibrators Laboratory Field Use Wide Temperature Range CALsys 120SP offer a wide temperature range from 0 °C to 120 °C Lightweight, portable The CALsys 120SP block is ideal for Industrial/ Laboratory field use. It only weights about 8 kg, and it is small enough to carry around. Speed The CALsys 120SP extremely quick to reach various temperatures, i.e. it cools down to 100 °C in 80 minutes and heats up room temp 0 to +120 °C in 20 minutes. This saves time and increases productivity. Accuracy and performance CALsys 120SP offers medium temperature range from 0 to 120°C. It is a The CALsys 120SP is an easily portable unit that also provides excellent calibration highly stable standard temperature source for calibrating RTD accuracy with stability ± 0.07°C at 120 °C. /thermocouples. It has peltier elements to generate stable temperature in the well. Use as a dry block & liquid bath using magnetic stirrer in one Accredited calibration model. The comparison volume is a metallic block of aluminum, which Each CALsys 120SP is delivered with an has diameter of 24mm and 100mm length. The temperature of the accredited calibration certificate. calibrator is set and controlled by a self tuned PID controller with automatic super fine adjustment. Computer Interface With the Tempsens make Compact Temperature Calibrator, you have The communication port(RS-232/ USB) chosen an extremely effective instrument which we hope will live up to enables communication with selected CALsys all your expectations. This is a fast, timesaving, and reliable true 120SP calibrators for automation calibration and documentation thus it made documenta- industrial temperature calibrator designed for on-site use. tion easy. During the past several years, we have acquired extensive knowledge of industrial temperature calibration. This expertise is reflected in our products which are all designed for daily use in an industrial environment.
SPECIFICATIONS Temperature range 0 to 120°C Temperature Resolution 0.1°C ± 0.03°C at 0°C Stability ±0.05°C at 50°C ±0.07°C at 120°C ±0.05°C at 0°C Uniformity ±0.07°C at 50°C ±0.09°C at 120°C Controlling Sensor Precision PRT Medium Silicon Oil (for liquid bath) Method of Control Digital self tuned PID Controller Insert Construction Dia 24 x 100 mm long, 3 x 6 mm hole Time to Reach Max/Min Temp 20 to 25°C Operating Temperature 20 to 45°C Computer Interface RS - 232 Power Requirement 230 VAC, 500 W Dimensions 380(H) x 170(W) x 188(D) mm Weight 14 Kg (without packing) STABILITY / UNIFORMITY CALsys 120SP 0.1 Temperature in °C 0.08 0.06 0.04 0.02 0 0 50 120 Temperature in °C STABILITY UNIFORMITY ACCESSORIES STANDARD ACCESSORIES KEY FEATURE Ÿ Reference Standard PRT......Part No.TPRT -A-300 Ÿ Wide Operating Range (0 to120°C) Ÿ NABL accredited calibration certificate - 3 point Ÿ High Stability Ÿ Software - Cal Soft including for setting bath Ÿ PC interfacing temperature and monitoring the PV. Graphical Ÿ Simple to use and cost effective representations of PV/TIME with 2 hours data logging. Ÿ Portability Ÿ Operational Manual Ÿ Carry Case Carrying Case Customized Equalizing Block....Part No. EQ1 Tempsens Instruments (l) Pvt. Ltd. U# ll A-190, Road No.5, M.I.A., Udaipur-313003 (Rajasthan) INDIA Ph.:+91-294-3500629, Fax.:+91-294-3500631 Email: calsys@tempsens.com, info@tempsens.com
CALsys 500 Portable, Dry Block Temperature Calibrator Dry Block Calibrators for Industrial/ Laboratory Field Use Wide Temperature Range CALsys 500 offer a wide temperature range from 50 °C to 500 °C Lightweight & portable The CALsys 500 block is ideal for Industrial/ Laboratory field use. It only weights about CALsys 500 3.80 kg, and it is small enough to carry around. Speed The CALsys 500 extremely quick to reach various temperatures, i.e. it cools down to 100 °C in 80 minutes and heats up room temp 50 to 500 °C in 20 minutes. This saves time and increases productivity. Accuracy and performance CALsys 500 offers medium temperature range from 50 to 500°C. It The CALsys 500 is an easily portable unit that is a highly stable standard furnace for calibrating thermocouples / also provides excellent calibration accuracy RTD. The comparison volume is a metallic block of aluminum, with stability ±0.05°C at 500°C. which has diameter of 27mm and 120mm long. The temperature of the calibrator is set and controlled by a self tuned PID controller Accredited calibration with automatic super fine adjustment Each CALsys 500 is delivered with an accredited calibration certificate. With the Tempsens make Compact Temperature Calibrator, you have chosen an extremely effective instrument which we hope will live up to Computer Interface all your expectations. This is a fast, timesaving, and reliable true The communication port(RS-232/ USB) industrial temperature calibrator designed for on-site use. enables communication with selected CALsys 500 calibrators for automation calibration During the past several years, we have acquired extensive knowledge of and documentation thus it made industrial temperature calibration. This expertise is reflected in our documentation easy. products which are all designed for daily use in an industrial environment.
SPECIFICATIONS Temperature range 50 to 500°C Temperature Resolution 0.1°C Stability ±0.05°C at 500°C Radial Uniformity ±0.3°C at 500°C Time to Reach Max. Temperature 25 Mins Time to Reach Mini Temp 80 Mins(Max temp 100°C) Controlling Sensor T/C “N” TYPE Method of Control Digital self tuned PID Controller Dia 27 x 120 mm long with 3 holes of 6.5 x110 mm Insert Construction insertion depth Computer Interface RS - 232 Operating Temperature 20 to 45°C Power Requirement 230 VAC, 1 KW Dimensions 270(H) x 154(W) x268(D) mm Instrument Weight 3.80 Kg(without packing) ACCESSORIES STANDARD ACCESSORIES OPTIONAL ACCESSORIES SOFTWARE Ÿ Customized Equalizing Block....Part No. EQ1 Ÿ Cal Soft including for setting bath temperature and monitoring the PV. Graphical representations of PV/TIME with 2 hours data logging. Customized Equalizing Block....Part No. EQ1 MASTER SENSOR CARRY CASE Ÿ Reference Standard Thermocouple (RTD)…… Part No. TTCK-300 Ÿ NABL accredited calibration certificate - 3 point Ÿ Tempsens makes customized carry case is a rugged, safe perfectly designed to carry our Ÿ Operational Manual new CALsys 500 calibrator and different accessories. Tempsens Instruments (l) Pvt. Ltd. U# ll A-190, Road No.5, M.I.A., Udaipur-313003 (Rajasthan) INDIA Ph.:+91-294-3500629, Fax.:+91-294-3500631 Email: calsys@tempsens.com, info@tempsens.com
& weight about 8 kg
, software Software oft Certificate genration optional
operating (Op onal)
specifications Tempsens Instruments (l) Pvt. Ltd. U# ll A-190, Road No.5, M.I.A., Udaipur-313003 (Rajasthan) INDIA Ph.:+91-294-3500629, Fax.:+91-294-3500631 Email: calsys@tempsens.com, info@tempsens.com
Highly accurate & Automatic Dry Block Calibrator for Industrial/Laboratory field use weight about 13kg
±0.1 °C at 250°C ±0.2°C at 700°C ±0.3°C at 1200°C software oft Software oft Certificate genration optional
operating (Op onal)
Inserts for Calsys 1200 Autocal & CALsys 1200 are made of special material. All specifications on hole size based on outer diameter of the sensor under test. We also offer customized hole size based on Customer requirements. Tempsens Instruments (l) Pvt. Ltd. U# ll A-190, Road No.5, M.I.A., Udaipur-313003 (Rajasthan) INDIA Ph.:+91-294-3500629, Fax.:+91-294-3500631 Email: calsys@tempsens.com, info@tempsens.com