                                                                                                                                          WADiana® Compact
                                                                                                                                          Instrucciones de Utilización
                                                                                                                                          Instructions for Use

                                                                                                WADiana® Compact

      Diagnostic Grifols, S.A.
      Passeig Fluvial, 24, 08150 Parets del Vallès, Barcelona - ESPAÑA (SPAIN)                                                                                           3034072 12/2011
      Tel. [34] 935 710 400 Fax [34] 935 731 132 www.grifols.com
3034072 Wadiana ES-EN:GRIFOLS      1/2/12      09:30     Página 49

                                   WADiana® Compact
                                            Instructions for use

                    Diagnostic Grifols, S.A. Passeig Fluvial, 24 - 08150 Parets del Vallès, ESPAÑA (SPAIN)
3034072 Wadiana ES-EN:GRIFOLS   1/2/12   09:30   Página 50
3034072 Wadiana ES-EN:GRIFOLS   1/2/12   09:30    Página 51

                        PLEASE READ CAREFULLY THESE INSTRUCTIONS
                    BEFORE STARTING TO WORK WITH THE WADIANA® COMPACT

             chapter 2 contents all the information referred to the equipment safety. e
             symbols used in these instructions are:

                                NOTE:
                                Used for clarification and complementary or
                                emphasised information.

                                DANGER!
                                Any kind of injure –critical or not– for people,
                                that only can be diminished following the
                                instructions shown.

                                WARNING!
                                Any kind of injure for people, for which other
                                protection systems are provided, but it is
                                convenient the RESPONSIBLE AUTHORITY or the
                                OPERATOR knows it.

                                CAUTION!
                                Any kind of harmful situation for equipment or
                                others. This situation can be diminished using this
                                indication or with other protections.
3034072 Wadiana ES-EN:GRIFOLS   1/2/12   09:30   Página 52

             Definitions:
             RespOnsible AuThORiTy: Individual or group responsible for the use
             and maintenance of equipment, and for ensuring that operators are
             adequately trained.
             OpeRATOR: Person operating equipment for its intended purpose. e
             operator should have received appropriate training for this purpose.
             QuAlifieD TeChniCiAn: Person responsible for the installation,
             reparation and special maintenance of the equipment who has received
             specific training for this purpose.
             All restrictions referred to RESPONSIBLE AUThORITy are valid for
             OPERATOR.

           Equipment design and specifications are subjected to change without previous
           notification.
3034072 Wadiana ES-EN:GRIFOLS               1/2/12         09:30        Página 53

             WADiana® Compact                                                                                                              Index

             INDEX

             1 IntroDuctIon ..............................................................................................1.1
               1.1  INTENDED USE.......................................................................................................1.2
               1.2  PURPOSE, LImITATIONS AND TRAINING
                    Of ThE DE OPERATORS WhO hAvE TO USE ThE EqUIPmENT ................................1.2
               1.3  EqUIPmENT PARTS ................................................................................................1.3

             2 safety InformatIon .................................................................................2.1
               2.1     GENERAL INfORmATION ABOUT SAfETy ..............................................................2.1
               2.2     EqUIPmENT mARKING ..........................................................................................2.3
                 2.2.1   Rating plate ....................................................................................................2.3
                 2.2.2   Label of biohazard and risk of injury with the probe ...............................2.4
                 2.2.3   Label sample carrousel .................................................................................2.4
                 2.2.4   Labels of the wash solution bottles .............................................................2.5
                 2.2.5   Labels of the waste bottle and the card disposal tray................................2.5
                 2.2.6   Equipment packaging label..........................................................................2.6
               2.3     READ BEfORE USING .............................................................................................2.7

             3 equIpment features .................................................................................3.1
               3.1     TEchNIcAL SPEcIfIcATIONS .................................................................................3.1
                 3.1.1    Reagents and washing solutions..................................................................3.2
                 3.1.2    complementary accessories to WADiana System ....................................3.2
               3.2     STANDARDS ThE EqUIPmENT cOmPLIES WITh USE ThE EqUIPmENT ...................3.2

             4 equIpment functIons ..............................................................................4.1
               4.1     DEScRIPTION Of ThE EqUIPmENT fUNcTIONS .....................................................4.1
                 4.1.1    Pipette system ................................................................................................4.1
                 4.1.2    centrifuge ......................................................................................................4.1
                 4.1.3    Image processing reader...............................................................................4.2
                 4.1.4    card transport system through each one of the various modules
                          in the equipment ...........................................................................................4.2
               4.2     cOmmANDS AND cONTROLS ...............................................................................4.2
                 4.2.1    ON/Off switch .............................................................................................4.3
                 4.2.2    Doors ..............................................................................................................4.3
                 4.2.3    Indicator leds .................................................................................................4.5
                 4.2.4    manual opening ring ....................................................................................4.5
                 4.2.5    Other operations ...........................................................................................4.6
               4.3     SySTEm SELf-chEcKS ............................................................................................4.7
               4.4     BASIc ThEORy Of OPERATION...............................................................................4.8

                                                                                                                                                i
3034072 Wadiana ES-EN:GRIFOLS                  1/2/12        09:30        Página 54

           WADiana® Compact                                                                                                              Index

           5 InstallatIon.................................................................................................5.1
                5.1        AcTION DURING DELIvERy ...................................................................................5.1
                5.2        INSTALLATION REqUIREmENTS..............................................................................5.1
                5.3        cONNEcTION DIAGRAm ........................................................................................5.2

           6 operatIng InstructIons ........................................................................6.1
             6.1     PREPARATION BEfORE USE ....................................................................................6.1
               6.1.1    checks and adjustments...............................................................................6.1
             6.2     OPERATING PROcEDURE .......................................................................................6.2
               6.2.1    Processes in which the operator intervenes ..............................................6.2
                 6.2.1.1 Selection of the test to be performed........................................................6.2
                 6.2.1.2 Introduction of samples..............................................................................6.3
                 6.2.1.3 Introduction of reagents and diluents......................................................6.4
                 6.2.1.4 Introduction of cards ..................................................................................6.5
               6.2.2    Automatic processes .....................................................................................6.5
                 6.2.2.1 The equipment will check the entered load of samples,
                           reagents and cards .......................................................................................6.5
                 6.2.2.2 Pipette............................................................................................................6.6
                 6.2.2.3 Incubation.....................................................................................................6.6
                 6.2.2.4 Automatic transport....................................................................................6.6
                 6.2.2.5 The centrifuge of cards during the time determined
                           by the selected technique............................................................................6.6
                 6.2.2.6 The unloading of the cards one-by-one...................................................6.6
             6.3     cLOSING PROcEDURE ............................................................................................6.7
               6.3.1    Placing on stand-by.......................................................................................6.7
               6.3.2    complete equipment stop ............................................................................6.7
               6.3.3    Emergency stop .............................................................................................6.7
             6.4     SPEcIAL PROcESSES ...............................................................................................6.7

           7 maIntenance ................................................................................................7.1
             7.1     mAINTENANcE PLAN ............................................................................................7.1
             7.2     cLEANING AND DEcONTAmINATION INSTRUcTIONS ............................................7.2
               7.2.1   cleaning instructions ...................................................................................7.2
               7.2.2   Decontamination instructions ....................................................................7.3

           8 transport anD storage .........................................................................8.1
             8.1  EqUIPmENT STORAGE ..........................................................................................8.1
             8.2  UNPAcKING ThE EqUIPmENT ..............................................................................8.1
             8.3  PLAcING ThE EqUIPmENT IN ITS OPERATION POSITION ......................................8.2

           9 equIpment DIsposal ..................................................................................9.1
           10 Warranty.....................................................................................................10.1
           maIntenance servIces carrIeD out .........................................................I

           ii
3034072 Wadiana ES-EN:GRIFOLS   1/2/12   09:30   Página 55

             WADiana® Compact                                                       Introduction

             1 INTRODUCTION

                          THIS EQUIPMENT IS AN IN VITRO DIAGNOSTIC
                                    MEDICAL DEVICE (IVD)

             e WADiana® Compact is a Pc-controlled instrument that automates the
             immuno- haematology techniques in gel.
             e automatic procedures are:
                    •    Positive sample identification: is identification is performed in
                         such a manner that, at all times, the results are ensured to be
                         correlated with the sample bar code label.
                    •    Positive reagent identification. e reagents are diluents, red blood
                         cell reagents, anti-serum and enhance solutions.
                    •    Positive card identification.
                    •    card transport system among the various equipment modules.
                    •    Sample dilution.
                    •    Serum and/or plasma dispensing.
                    •    Red blood cell suspension dispensing.
                    •    Reagent dispensing.
                    •    Incubation.
                    •    centrifuging.
                    •    Reading.
                    •    Result interpretation.
             ese instructions refer only and exclusively to the WADiana® Compact. Since
             a Pc is needed for this operation, we refer to the soware but only by way of an
             example. complete soware instructions are given in the Soware Manual,
             which is included with the equipment.

                                                                                            1.1
3034072 Wadiana ES-EN:GRIFOLS     1/2/12   09:30   Página 56

           WADiana® Compact                                                           Introduction

           1.1   Intended use
           is instrument has been designed for laboratories that perform test of
           Immunohaematology, among others, to study donor/receptor compatibility in
           blood transfusion and the diagnosis of maternal/fetal blood group
           incompatibility.
           e basis of all tests performed with this instrument is the reaction between the
           haematic antigen and the antibody in the serum or reagent that produce and
           agglutination of the red blood cells that can be detected in the filtration process
           through the gel column.
           e tests that can be performed are as follows:
                 •     forward ABO group.
                 •     Reverse ABO group.
                 •     Antibody screening.
                 •     Antibody identification.
                 •     Rh phenotypes.
                 •     Extensive phenotypes.
                 •     Direct coombs.
                 •     crossmatching tests.

           1.2   Purpose, limitations and training of the operators who have to use
                 the equipment
           e purpose of this instrument is to carry out immuno-haematological
           techniques automating all operations sequence in order to:
                 •    Increase process safety reducing possible errors in identification and
                      transcription.
                 •    Increase analytical reliability standardizing all steps to reduce possible
                      handling errors and performing results interpretation with objective
                      criteria.
                 •    Reduce dangers of OPERATOR contamination reducing OPERATOR
                      interaction with samples and reagents during the analytical process.
           Limitations:
                 •    e instrument is only prepared for performing immuno-
                      haematology tests and it is not possible to carry out other types of
                      tests different than those to which it is destined.
                 •    e instrument can only use cards with gel microtubes.

           1.2
3034072 Wadiana ES-EN:GRIFOLS   1/2/12   09:30    Página 57

             WADiana® Compact                                                       Introduction

                   •     Positive identification depends on the tubes, cards, diluents and
                         reagents being identified by bar codes. In order to guarantee the
                         maximum reliability in sample identification, the use of bar codes
                         with control digit (cheksum) is recommended.
                   •     Doubtful or discrepant reactions should be validated by the
                         OPERATOR.
             To use the WADiana® Compact, the OPERATOR should be trained to
             laboratory technician level and have knowledge of immuno-haematology. e
             OPERATOR should be familiar with the instrument’s automatic techniques,
             possess a minimum Windows® user level and should be trained to use the
             WADiana® Compact.

             1.3   Equipment parts
             Access to the equipment interior is done through a sliding door (1) and a moving
             lid (2), (figure 1-1).

                                                                1

                                            1:8
                                                                2

                                            figure 1-1: Doors

             Access to the instrument can only be done via soware. is means that it can
             only be opened by pressing the ‘open’ button on the computer screen (the
             soware and the instrument must be switched ON). Doing it, the upper door (1)
             slides to the top and it is possible to open manually the lower door (2).
             Once the door is open we can see the following parts (figure 1-2):

                                                                                            1.3
3034072 Wadiana ES-EN:GRIFOLS           1/2/12      09:30        Página 58

           WADiana® Compact                                                                                  Introduction

                 •             Sample carrousel. With capacity for 48 tubes having a diameter
                               between 10 and 15 mm (3)
                 •             Reagent tray. With capacity for 16 reagents and 2 diluents (4)
                 •             Working table. With capacity for 24 cards in two blocks of 16 and 8
                               cards (5,6)
                 •             centrifuge for 12 cards (7)
                 •             Service rack for 12 cards (8)
                 •             Waste bottle (9), Wash Solution A bottle (10) and Wash Solution B
                               bottle (11). capacity: 4 litre each one.
                 •             card disposal tray (12)
                 •             Dilution station (13)
                 •             Balancing card (14)
                 •             Reader (15)
                 •             Arm with a pipette probe and transport gripper (16)
                 •             Digital pump (17)
                 •             Rating plate (18)
                 •             On/off switch and connections (19)

                                         14       15

                                                                                           1

                                                                                               17

                     18
                                                                                                    7
                     4

                 3                                                                                  20        19

                 2                                                                                       8

                          13        5     9        10       11               6   16   12

                                              figure 1-2: parts identification

           1.4
3034072 Wadiana ES-EN:GRIFOLS   1/2/12   09:30    Página 59

             WADiana® Compact                                                         Safety information

             2 SAFETY INFORMATION

             2.1   General information about safety
             e following indications have a direct involvement in the equipment safety:

                                DANGER!
                                Misuse of the equipment can impair the
                                protection provided by it.

                                WARNING!
                                To avoid the risk of electric shock, this equipment
                                must only be connected to electrical mains with
                                protective earth.

                                DANGER!
                                This equipment works with some substances that
                                carry a chemical or biological risk. The
                                established regulations for working in laboratories
                                in relation to the use of suitable gloves or other
                                personal protective means should be followed.

                                DANGER!
                                In the event of any spillage into the equipment, it
                                must be isolated from the electrical supply,
                                cleaned up and decontaminated. In any case the
                                instrument must be disassembled and the
                                equipment must not be reconnected until it has
                                been fully inspected by a QUALIFIED TECHNICIAN.

                                                                                                    2.1
3034072 Wadiana ES-EN:GRIFOLS    1/2/12    09:30   Página 60

           WADiana® Compact                                                    Safety information

                          WARNING!
                          Electromagnetic compatibility and electrical
                          safety tests have been performed using the cord
                          supplied by the manufacturer. However, if it is
                          necessary to use another cord, be sure that the
                          new cord meets the following specifications:
                          Cable type: flexible cable with insulation and PVC
                          cover with 3 conductors (neutral, live and earth).
                          Cord length: 2m
                          Conductor section: 1mm2 or higher
                          Connector type: For IEC inlet. Connector for class
                          I appliances.
                          Plug type: Plug type used in the country where
                          the equipment will be installed, with earth
                          connection.
                          Connector, cable and plug must comply electrical
                          safety requirements applicable in your country.

                          WARNING!
                          This equipment only must be used by
                          RESPONSIBLE AUTHORITY, OPERATORS and
                          QUALIFIED TECHNICIAN.

                          WARNING!
                          Basic safety precautions must always be taken,
                          including those indicated in 2.3 section "Read
                          before using". Furthermore, before installing the
                          instrument, the rules of 5.2 section "Installation
                          requirements" must be read.

           2.2
3034072 Wadiana ES-EN:GRIFOLS   1/2/12    09:30   Página 61

             WADiana® Compact                                                         Safety information

                                 CAUTION!
                                 Using cables other than those specified may
                                 result in increased electromagnetic emissions
                                 and/or decreased immunity of the equipment.

                                 CAUTION!
                                 The equipment should not be used adjacent to or
                                 stacked with other equipment which are not
                                 included in the system. If adjacent or stacked use
                                 is necessary, the equipment should be observed
                                 to verify normal operation in the configuration in
                                 which it will be used.

             2.2     Equipment marking
             e labels used to provide information on the equipment are as follows:

             2.2.1    Rating plate
             is is located at the rear of the equipment next to the switch (figure 1-2)(18)).
             It contains technical information about the equipment, such as serial number,
             manufacturing date, model and name and address of the manufacturer.

                                                                                                    2.3
3034072 Wadiana ES-EN:GRIFOLS    1/2/12   09:30   Página 62

           WADiana® Compact                                                        Safety information

           e following symbols are used:

                          year of manufacture

                          Serial number

                          medical product for in vitro diagnostics

                          e WADiana® analyzer meets the requirements of Directive
                          98/79/Ec.

                          Indicates that the WADiana ® analyzer is subject to selective waste
                          collection at the end of its useful life, as established by Directive
                          2002/96/Ec on Waste Electrical and Electronic Equipment. See
                          chapter 9 “EqUIPmENT DISPOSAL”.

           2.2.2   Label of biohazard and risk of injury with the probe
           is is located on the front face of the mobile arm where the probe is. is label,
           composed of two symbols, is used to warn of the potential risk of infection and
           the risk of injury caused by the probe if this area is approached.

                         figure 2-1: biohazard and risk of injury with the probe

           2.2.3   Label of sample carrousel
           is is located on the sample carrousel and provides information about the
           sample number to which each carrousel location corresponds (figure 1-2 (3)).

           2.4
3034072 Wadiana ES-EN:GRIFOLS   1/2/12    09:30   Página 63

             WADiana® Compact                                                    Safety information

             2.2.4   Labels of the wash solution bottles
             ese labels are located on the front face and the cap of the wash solution bottles
             (figure 1-2 (10) and (11)) and on the base where they are placed. ey are used
             to identify content and place of each bottle.

                                   figure 2-2: Wash solution a bottle label

                                   figure 2-3: Wash solution b bottle label

             2.2.5   Labels of the waste bottle and the card disposal tray
             ey are located on the red cap and the front face of the waste bottle (figure 1-
             2 (9)), and also on the front face of the card disposal tray (figure 1-2 (12)). ey
             are used to warn on these recipients content, which is potentially infectious.

                                             BIOHAZARD
                                          RIESGO BIOLÓGICO

                                         figure 2-4: biohazard label

                                                                                               2.5
3034072 Wadiana ES-EN:GRIFOLS   1/2/12    09:30   Página 64

           WADiana® Compact                                                Safety information

           2.2.6   Equipment packaging label

           e following symbols are used:

                          Serial number

                          catalogue number

                          Permitted temperature range during storage and transport

                          Permitted relative humidity range during storage and transport

                          medical product for in vitro diagnostics

                          e WADiana® Compact analyzer meets the requirements of
                          Directive 98/79/Ec.

           2.6
3034072 Wadiana ES-EN:GRIFOLS   1/2/12   09:30   Página 65

             WADiana® Compact                                                  Safety information

             2.3   Read before using
             Bear in mind the following remarks before using the equipment:
                   •    Use the equipment only for the purpose described in the Instructions
                        for Use.
                   •    Unless specified by the instructions for use, do not introduce or put
                        anything into any opening in the equipment.
                   •    Do not use the equipment if it is not working properly, or if it has
                        suffered any damage. Examples of common defects include:
                             - Damage caused by fall of the equipment.
                             - Damage caused by liquid spillage.
                             - Damage caused by prolonged storage under unfavorable
                               conditions or by subjection to severe transport stresses.
                             - Damage to the flexible supply cord or its plug.
                   •    Do not use the equipment in hazardous atmosphere, or with
                        hazardous materials for which the equipment has not been designed.
                   •    Do not use accessories that are not supplied or recommended by the
                        manufacturer.
                   •    for refilling the bottles, they must be taken away from the equipment,
                        previously.
                   •    main fuses only must be replaced by a qUALIfIED TEchNIcIAN.
                        is instrument should only be disassembled by a qUALIfIED
                        TEchNIcIAN, either for internal cleaning and/or for repairing.
                   •    Before disassembling the equipment must be unplugged.
                   •    Do not introduce in the centrifuge flammable or explosive materials
                        or materials which chemically interact vigorously.
                   •    Switch off the equipment aer use.

                                                                                             2-7
3034072 Wadiana ES-EN:GRIFOLS   1/2/12   09:30   Página 66
3034072 Wadiana ES-EN:GRIFOLS   1/2/12   09:30     Página 67

             WADiana® Compact                                                      Equipment features

             3 EQUIPMENT FEATURES

             3.1   Technical specifications

              moDel:                      WADiana® Compact
              supply:                     voltage:                100-120 / 220-240 v~
                                          frequency:              50-60 hz
                                          Input power:            300 W
                                          fuses:                  2 x T4A L 250v, 5x20 mm

              protectIon agaInst
                                          class:                  I
              electrIc shocK:
              InstallatIon                Overvoltage category II (local levels, appliances,
              category:                   portable equipment, etc.)
              DImensIons (mm):            600 (depth) x 1000 (width) x 650 (height with closed
                                          door)
              WeIght (Kg):                Approximately 87 kg
              materIals:                  packaging: wood, ethafoam.
                                          equipment: aluminium, stainless steel, iron,
                                          polyurethane (expanded foam), glass, electronic
                                          components (silicon, cupper...)...

              operatIng                   Indoor use
              conDItIons:
                                          temperature:            15 ºc to 28 ºc

                                          maximum relative         80%
                                          humidity non
                                          condensing:

                                          minimum relative        30%
                                          humidity non
                                          condensing:

                                          maximum altitude:       2000m.

                                          mains supply            ±10% of nominal voltage
                                          maximum voltage
                                          fluctuations:

                                                                                                  3.1
3034072 Wadiana ES-EN:GRIFOLS    1/2/12    09:30   Página 68

           WADiana® Compact                                                    Equipment features

            transport                     temperature:           -10 ºc to 60 ºc
            anD storage
            conDItIons:                   maximum relative
                                          humidity non           85%
                                          condensing:
            centrIfuge:                   maximum load:          12 cards
            bottles' WorKIng              approx. 180 mbar (pressure)
            pressure:                     < 300 mbar (vacuum)

           computer requirements: controlled by Pc Pentium with 32 mb of RAm or
           higher, with BUS SLOT PcI and parallel port LPT1. A minimum of one standard
           serial RS-232c port is needed.
           e WADiana® Compact has been designed and tested so that it complies with
           all the necessary requirements of accuracy and reproducibility in the handling
           of liquids, contamination, temperature stability and accuracy, precise mechanical
           movements and all those parameters that might affect the specific tests for which
           it has been designed.
           Any other specifications are not guaranteed, especially in the case where the
           equipment is used for functions other than the ones for which it has been
           designed.

           3.1.1    Reagents and washing solutions
           e soware communicates the reagents and cards required for carrying out
           the technique once it has been selected. moreover, Wash solution A and Wash
           solution B must be used with the equipment.

           3.1.2    Complementary accessories to WADiana System
           As well as the previously mentioned Pc, the following complements may be used
           with the system:
                 •      A bar code reader for the identification of the samples, cards and tubes
                        in the specific operating situations (delivered with the equipment).
                 •      A printer for obtaining a hard copy of the obtained results.
                 •      Diana Bcc: bar code replicating printer.

           3.2     Standards the equipment complies with use the equipment
           e equipment conforms to the requirements of the Directive 98/97/Ec of the
           European Parliament and of the council on “In vitro Diagnostic medical
           Devices”

           3.2
3034072 Wadiana ES-EN:GRIFOLS      1/2/12   09:30   Página 69

             WADiana® Compact                                                  Equipment functions

             4 EQUIPMENT FUNCTIONS

             4.1     Description of the equipment functions
             e WADiana® Compact functions are those described in the intended use
             (chapter 1.1). In order to carry out these functions, the equipment incorporates
             various parts:
                   1) Pipette system
                   2) centrifuge
                   3) Image processing reader
                   4) card transport system through each one of the various modules in
                        the equipment.

             4.1.1    Pipette system
             is consists of:
                   •     Sample carrousel.
                   •     Reagent and diluent carrousel.
                   •     Working table.
                   •     Dilution station.
             is part of the equipment is based on a digital pump and a fluid system. e
             pump sucks in and measures a suitable amount of sample and reagent according
             to the test being performed. ese substances are carried through the fluid
             system to the reagent card where they are applied via the sampling probe.

             4.1.2    Centrifuge
             is has been designed to centrifuge the reagent cards at the required speed and
             for the necessary time required by each specified technique.
             It precisely positions each one of the cavities in order to receive the cards from
             the automatic transport system and thus avoiding any possible imbalances.
             In a situation where the number of cards in the current batch does not permit
             a balanced load, a supplementary card, reserved for such a purpose, will be used.

                                                                                              4.1
3034072 Wadiana ES-EN:GRIFOLS    1/2/12   09:30   Página 70

           WADiana® Compact                                                   Equipment functions

                          WARNING!
                          This equipment element was not designed to be
                          manipulated in any way by the OPERATOR.

                          WARNING!
                          The centrifuge contained in this equipment must
                          not be used independently. It has been designed
                          to be automatically loaded and unloaded with the
                          materials described in this manual and must not
                          be used for any other purpose.

           4.1.3    Image processing reader
           is is based on a ccD camera and an image acquisition card located inside the
           Pc. e objective is to take a photo of the reagent card in order to carry out later
           morphological analysis, from which the result of the performed test will be
           determined.

           4.1.4    Card transport system through each one of the various modules in the
                    equipment
           is consists of an arm that transports the cards through each one of the
           equipment modules, and includes the pipette probe.

           4.2     Command and controls
           In this chapter we will identify all the points that are accessible to the
           OPERATOR and their function within the equipment as a whole.

           4.2
3034072 Wadiana ES-EN:GRIFOLS   1/2/12   09:30     Página 71

             WADiana® Compact                                                       Equipment functions

             4.2.1   ON/OFF switch

                                             1:8

                                                                MAINS CABLE CONNECTION

                                                           ON/OFF SWITCH

                                         figure 4-1: on/off switch

             It has two positions:
                     •   O: off
                     •   | : On

             4.2.2   Doors
             e WADiana® Compact has two doors on the equipment front face.

                                                                                                   4.3
3034072 Wadiana ES-EN:GRIFOLS   1/2/12   09:30   Página 72

           WADiana® Compact                                            Equipment functions

                                                             1

                                          1:8
                                                             2

                                         figure 4-2: Doors

           e upper door opens under soware control from the Pc. Behind it, there are
           the whole transport system and all the equipment’s functional elements: the
           sample and reagent carrousel, the centrifuge, incubators...

                                          1:8

                                    figure 4-3: Doors movement

           4.4
3034072 Wadiana ES-EN:GRIFOLS    1/2/12   09:30     Página 73

             WADiana® Compact                                                 Equipment functions

             e lower door opens by pulling it down in the direction of the arrow. however,
             this is only possible if the upper door is already open. erefore WADiana®
             Compact equipment can only be accessed when it is not operating in a way that
             is potentially dangerous for the OPERATOR.
             is lower door allows the access to the bottles for the wash and waste solutions,
             as well as to the lower tray for collecting the used cards.
             e bottles as well as the used card tray have been designed so that they may be
             easily taken out.
             e bottles for the wash and waste solutions as well as the used card collection
             tray can be removed from the WADiana® Compact by pulling them. en they
             may be filled or emptied as required.

             4.2.3   Indicator leds

                         LED 1

                         LED 2
                                              1:8

                                          figure 4-4: Indicator leds

             ere are two green indicator leds on the lower door. ese indicator leds
             provide the following information:
                   •    Led 1: indicates if the equipment is switched on or off.
                   •    Led 2: indicates equipment access. It is on whenever the door may be
                        opened for accessing to the interior of the equipment.

             4.2.4   Manual opening ring
             is ring is located within a covered cavity and can be accessed by removing
             the screw with a tool. is cover allows the front door to be opened in the
             situation where the electronic opening system does not work.

                                                                                             4.5
3034072 Wadiana ES-EN:GRIFOLS    1/2/12       09:30   Página 74

           WADiana® Compact                                                 Equipment functions

                          WARNING!
                          Not usable by the OPERATOR nor the
                          RESPONSIBLE AUTHORITY, only for use by the
                          QUALIFIED TECHNICIAN.

           4.2.5   Other operations
           Other operations that require OPERATOR interaction are as follows:
                 •    e sample carrousel: is consists of a 48-sample tube capacity
                      carrousel. It can be used with various sizes of tube without adapter
                      (10, 12 or 15 mm tubes).
                 •    Reagent carrousel: It has capacity for 18 containers, two of which are
                      for diluents and the rest for reagents.
           Both carrousels should only be removed for equipment maintenance or cleaning
           purposes.

                                                        3

                                                                    2

                                          1

                              figure 4-5: card loading and unloading area

           4.6
3034072 Wadiana ES-EN:GRIFOLS   1/2/12   09:30    Página 75

             WADiana® Compact                                                  Equipment functions

                   •     card incubating blocks (figure 4-5 (1)): ere are two blocks
                         available that can be heated to two different temperatures: 24 °c or
                         7 ºc. ese are used to incubate the cards according to the
                         temperature and time that the technique being used requires.
                   •     service rack (figure 4-5 (2)): is is where he equipment places the
                         cards that it has not been able to read correctly, the results of which
                         are doubtful. It is also the location for half-used cards that are not
                         discarded in case they can be used with the following batch.
                   •     a rack for the card to be used in case of unbalance (figure 4-5 (3)):
                         is rack is used to hold the reserve card that is only used in the case
                         the centrifuge is not balanced once the batch of cards has been
                         loaded. In such a case the equipment will place the card in a suitable
                         position in the centrifuge so that it operates correctly.
                   •     bar code reader: is reader is used for the identification of the
                         processed samples, of the cards to be used and of the reagents
                         corresponding to each technique in specific operating situations.

             4.3   System self-checks
             e WADiana® Compact equipment performs internal self-checks to ensure the
             correct operation of all the controlled elements.
             e following checks are carried out:
                   •     When the WADiana soware is started, it will check that each one
                         of the electronic component responds.
                   •     When the test to be carried out is selected, the following checks are
                         made:
                               - at there is a balancing card.
                               - at the service rack is empty.
                               - at there are no cards in the centrifuge.
             en it continues to positively identify the cards, reagents, samples and wash
             and waste solution levels.
             In order to do this, the following steps are performed:
                   1) It locates and identifies the reagents and checks the ‘expiry date’ and
                         that the reagent level is sufficient.
                   2) It agitates the reagents to avoid sedimentation of the red blood cells.
                   3) It locates, identifies the bar code and detects the diameter of sample
                         tubes.

                                                                                              4.7
3034072 Wadiana ES-EN:GRIFOLS    1/2/12   09:30   Página 76

           WADiana® Compact                                                  Equipment functions

                 4)    It checks that it has all the cards required for the selected test and
                       that they are of a suitable type, as well as the expiry date and lot.

           4.4   Basic theory of operation
           e WADiana® Compact is designed to reproduce as faithfully as possible the
           following steps performed manually and described in the instructions for use of
           the corresponding reagents for gel haematological tests:
                 •     reagent filling
                 •     sample filling
                 •     sample red blood cell dilution
                 •     incubation
                 •     centrifuge
                 •     results reading: it is based on morphological analysis performed
                       through image processing.
           In addition to this, the WADiana® Compact performs the following procedures:
                 •     process automation
                 •     sample and reagent positive identification
                 •     reading, interpretation and recording of results
                 •     report issue
           consult your distributor to obtain more information related to the tests and
           reagents that are validated to be used with the WADiana® Compact.

           4.8
3034072 Wadiana ES-EN:GRIFOLS   1/2/12   09:30   Página 77

             WADiana® Compact                                                        Installation

             5 INSTALLATION

             5.1   Action during delivery
             is equipment shall always be installed by a qUALIfIED TEchNIcIAN.
             e qUALIfIED TEchNIcIAN shall provide the OPERATOR with suitable
             instructions for putting the equipment into operation.
             When the equipment is received, it shall be checked to ensure it includes all the
             modules as specified on the attached packing list. e section 8 “Transport and
             Storage” instructions must be followed during the unpacking process.

             5.2   Installation requirements
             e requirements for the place where the equipment is to be installed are as
             follows:
                   •   Environmental conditions: see section 3.1 “Technical
                       specifications”
                   •   Space requirements: The equipment occupies a horizontal surface
                       area of 60 cm. depth x 100 cm width (0.6 m2), however, a
                       minimum installation space of 80 cm depth x 120 cm width is
                       recommended.
                   •   Do not place the equipment outdoors.
                   •   Do not place the equipment on a surface of flammable material.
                   •   Do not place the equipment where it is difficult to access for
                       maintenance or servicing.
                   •   Do not place the equipment where it could get wet.
                   •   Do not position the equipment so that it is difficult to operate the
                       mains disconnecting device.
                   •   Do not let the equipment or its flexible cord come in contact with
                       surfaces that are too hot to touch.
                   •   check that the plug outlet has an earth connection.
                   •   check that the nominal voltage shown on the equipment matches
                       the supply voltage.
                   •   Do not place anything on top of the equipment.

                                                                                             5.1
3034072 Wadiana ES-EN:GRIFOLS   1/2/12         09:30    Página 78

           WADiana® Compact                                                                     Installation

           5.3   Connection diagram

                                         PC WADIANA CONNECTIONS

                                    DETAIL A
                                                                     15 PINS CONNECTOR
                                                                     (VIDEO OUT CAMERAS)

                                                                    9 PINS CONNECTOR (RS-232)
                                                         DETAIL A   (PC/DG-57 COMMUNICATIONS)

                                          figure 5-1: connections

                                9 PINS CONNECTOR (VIDEO IN)

                        figure 5-2: video card –WADiana® Compact connection

           5.2
3034072 Wadiana ES-EN:GRIFOLS   1/2/12    09:30   Página 79

             WADiana® Compact                                                  Operating instructions

             6 OPERATING INSTRUCTIONS

             6.1     Preparation before use

             6.1.1    Checks and adjustments

                                 CAUTION!
                                 Neither the RESPONSIBLE AUTHORITY nor the
                                 OPERATOR are allowed to make any manipulation
                                 in the software supplied with the WADiana®
                                 Compact.

                                 CAUTION!
                                 To avoid possible software malfunction, it is
                                 recommended:
                                 1) Not installing any additional software and/or
                                    hardware as far as the strictly required.
                                 2) Disabling any screensaver and the Windows®
                                    energy saving mode.

             verify the WADiana is properly installed and the Pc with the operating system,
             the WADiana Soware and the image treatment card are also installed. To
             ensure that the equipment is under correct operating conditions, follow next
             steps:
                    •    check that the equipment is plugged into the electrical mains supply.
                    •    check that the switch is in position I (ON) and that the green
                         indicator led (figure 4-4 (Led 1)) is lit.
                    •    Enter the WADiana Soware by double clicking on the icon. At this
                         point the equipment will check system integrity and the
                         communications with the various components.
                    •    Open the door using the soware.
                    •    Open the lower li door and check that the wash and waste solution
                         bottles are present and correctly positioned, as well as that the waste
                         support tray is in a suitable position.

                                                                                                 6.1
3034072 Wadiana ES-EN:GRIFOLS        1/2/12   09:30   Página 80

           WADiana® Compact                                                   Operating instructions

                   •      Prepare wash solutions A and B according to the instructions for use
                          of the wash products (this step may be omitted if the solutions are
                          already prepared).
                   •      check that the samples and reagents are present in the carrousel.

                             CAUTION!
                             The calibration and adjustments of the WADiana
                             Compact must be performed only by a QUALIFIED
                             TECHNICIAN.

           6.2     Operating procedure

           6.2.1       Processes in which the operator intervenes
           We must follow these steps so that the WADiana® Compact is able to
           automatically perform all the required processes for the selected technique with
           the information we supply:
                  1) Selection of the test to be performed.
                  2) Introduction of samples.
                  3) Introduction of reagents and diluents.
                  4) Introduction of cards.

                             NOTE:
                             This order may be changed for experienced
                             OPERATORS.

           e first thing to do once the equipment is switched on, is to open the front
           door through the soware. en, batch preparation can take place.

           6.2.1.1        Selection of the test to be performed
           We can select any of the sowared immuno-haematological techniques via the
           WADiana soware. Once the test has been selected, we can introduce the
           samples, reagents and cards.

           6.2
3034072 Wadiana ES-EN:GRIFOLS   1/2/12   09:30     Página 81

             WADiana® Compact                                                   Operating instructions

             6.2.1.2     Introduction of samples
             e tubes of samples to be processed are introduced consecutively from position
             number one on the carrousel, turning the bar codes outwards.
             To warranty the maximum safety in the sample identification, it is recommended
             to use bar codes with control digit (checksum).
             moreover, the OPERATOR must be sure that the tubes contain enough sample
             (red blood cells and/or serum) to allow the pipetting process, being 250 µl the
             minimum detectable quantity (volume).
             Avoid bubbles in samples, especially if serum is transferred from primary tube
             to another.
             Avoid fibrin and clots in samples. Although they are detected by the system they
             are not advisable, because they stop the process and could block the syringe
             permanently.

                                CAUTION!
                                To the correct performance of the equipment, the
                                bar code labels must be well sticked on the
                                sample tube, and must not be written or
                                defective.

                                WARNING!
                                The use of hemolised or cloudy samples or with
                                clot or fibrin presence may lead to false positive
                                readings. Do not use such kind of samples with
                                the system.

                                                                                                  6.3
3034072 Wadiana ES-EN:GRIFOLS     1/2/12   09:30    Página 82

           WADiana® Compact                                                      Operating instructions

                          NOTE:
                          There is an exception to this procedure, which is
                          crossmatching test. The protocol to be followed
                          when introducing the samples for crossmatching
                          tests is:
                          • The first tube corresponds to the receptor and
                              all the consecutive tubes from this one are
                              possible donors.
                          • One empty position in the carrousel will indicate
                              that the next tube is a new receptor, followed
                              by the samples to crossmatch. Two empty
                              positions are interpreted as the end of samples.
                          It is necessary to work with sedimented red blood
                          cell samples. If it is necessary, use centrifuged
                          samples.
                          All this shall be done in accordance with the
                          instructions provided by the WADiana software.

           6.2.1.3     Introduction of reagents and diluents
           e soware will automatically provide information about the type of reagents
           and diluents to use according to the selected technique and amount of samples.
           By default the Pc will indicate in which position each one of the reagents has to
           go in case bar codes are not used.
           When using the bar codes, it is not essential to locate them in specific positions
           since the system is able to identify and locate each one of the reagents and
           diluents present on the carrousel.

           6.4
3034072 Wadiana ES-EN:GRIFOLS      1/2/12   09:30    Página 83

             WADiana® Compact                                                     Operating instructions

                                    CAUTION!
                                    To achieve a proper test execution, the reagents
                                    must be resuspended and allowed to reach room
                                    temperature when introduced, and the vials must
                                    be completely dry and the barcode label in good
                                    condition.

             6.2.1.4        Introduction of cards
             e soware will also provide the type, location and quantity of cards for
             processing of the current batch that must be introduced into the WADiana®
             Compact.

             6.2.2       Automatic processes
             Once all the necessary elements for processing the batch have been introduced,
             the front door may be closed manually and when the soware detects this, the
             automatic processing will begin according to the following sequence:

             6.2.2.1        The equipment will check the entered load of samples, reagents and
                            cards
                     •   It will identify all the introduced samples through their bar codes (if
                         they have not been manually identified).
                    •    It will check that the bar codes of the reagents and diluents correspond
                         to those indicated by the technique, this means the ones that have
                         been introduced are those previously requested and not others (*).
                    •    It will check the level of reagents and diluents to determine if there
                         is sufficient quantity to process the identified number of samples.
                    •    Once the cards have been placed in position, the equipment will
                         identify them and check that they are the requested ones and that
                         there is the necessary quantity.
             (*) ere is the possibility of loading all the necessary reagents at one time to
             process more than one batch. In this situation, the equipment will locate and
             identify them using only those required for the current batch.

                                                                                                    6.5
3034072 Wadiana ES-EN:GRIFOLS    1/2/12    09:30    Página 84

           WADiana® Compact                                                 Operating instructions

           6.2.2.2     Pipette
           is includes the priming of the fluid system and the injection of each one of the
           ‘blocks’ that are sowared in the test, which may be combinations of:
                 •     Dilutions (of sample red blood cells with the adequate diluent and
                       dispensing in the corresponding wells).
                 •     Reagents (cell suspension dispensing).
                 •     Serum (sample serum or plasma dispensing).
                 •     Diluents (diluent or other reagent dispensing).
                 •     Anti-serum (anti-serum dispensing in the appropriate wells).

           6.2.2.3     Incubation (if applicable)
           is consists of the transport of heat from the incubating block to the card
           during the time and at the temperature determined by the technique (24 °c or
           37 ºc).

           6.2.2.4     Automatic transport of the cards from the incubator block to the
                       centrifuge

           6.2.2.5     The centrifuge of the cards during the time determined by the
                       selected technique
           e centrifuge balance is carried out automatically by the soware according to
           the number of cards to centrifuge. e equipment is equipped with a balance
           sensor in order to ensure this balance security.

           6.2.2.6     The unloading of the cards one-by-one
           Automatically carrying them to the reader, where the results are read prior to
           discarding the cards or, according to the configuration, prior to returning the
           cards to the incubating blocks in order to conserve them.
           If there are doubtful cases, then the cards are taken to the service rack included
           for this purpose for later re-checking.

           6.6
3034072 Wadiana ES-EN:GRIFOLS   1/2/12      09:30   Página 85

             WADiana® Compact                                                 Operating instructions

                                 WARNING!
                                 WADiana® Compact results must be reviewed
                                 and validated by qualified personnel.

             6.3     Closing procedure

             6.3.1    Placing on stand-by
             e WADiana® Compact remains automatically on stand-by, once all the
             samples have been processed when the automatic process is ended.
             is stand-by situation can be identified by checking the soware’s main screen.

             6.3.2    Complete equipment stop
             In order to completely stop the equipment it is first necessary to exit the soware.
             On leaving the soware there is the possibility of a final wash of the fluid system,
             which has to be confirmed. To do so, the door must be closed. Once the door
             has been closed, the final wash will be carried out.
             e following step in order to disconnect functionally the equipment is to switch
             off the main switch. en the front le LED turns off.
             If you want to completely disconnect the equipment, disconnect the main cable.

             6.3.3    Emergency stop
             All the time, the screen will indicate the possibility of stopping the process via
             the STOP button.
             Once pressed, the process can be cancelled following the soware instructions,
             which implies complete process interruption.

             6.4     Special processes
             e system provides the possibility of configuring an automatic discarding of the
             cards or their conservation, which consists in returning the cards to the
             incubating blocks for later manual extraction.

                                                                                                6.7
3034072 Wadiana ES-EN:GRIFOLS   1/2/12   09:30   Página 86
3034072 Wadiana ES-EN:GRIFOLS      1/2/12   09:30   Página 87

             WADiana® Compact                                                       Maintenance

             7 MAINTENANCE

             7.1    Maintenance plan
             As a general rule whenever no kind of irregularity has occurred in the
             equipment operation, the maintenance plan shall be as follows:

                      tIme                          actIvIty               performeD

               Aer each session       final wash of the fluid circuit.     responsIble
               (daily)                 When daily work ends, the           authorIty /
                                       soware asks if a final wash is to    operator
                                       be carried out; the answer
                                       should be “yes”.
               Whenever samples        Reagent and sample carrousel        responsIble
               or other substances     cleaning as described in section:   authorIty /
               are spilled on the      7.2.1 “cleaning instructions”        operator
               carrousel.

               Every month             Equipment decontamination           responsIble
                                       described in section: 7.2.2         authorIty /
                                       “Decontamination instructions”       operator

               Every twelve months     check the general equipment          qualIfIeD
                                       condition (mechanical sample        technIcIan
                                       adaptors, throwaway tubes,
                                       calibration etc)

             maintenance operations carried out on the equipment shall be noted on the
             record “maintenance services carried out” included at the end of the Instructions
             manual.
             Technical assistance can be provided by your supplier or other Diagnostic
             Grifols' authorised services.

                                                                                            7.1
3034072 Wadiana ES-EN:GRIFOLS     1/2/12    09:30   Página 88

           WADiana® Compact                                                           Maintenance

           7.2     Cleaning and decontamination instructions

                          DANGER!
                          During cleaning and decontamination processes,
                          protective gloves must be used by the OPERATOR.

                           WARNING!
                           The equipment surfaces, dilution station and
                           probe cleaning works, shall be carried out with
                           the equipment unplugged from the electric mains
                           supply.

                           CAUTION!
                           Before using any cleaning or decontamination
                           methods different than those recommended by the
                           manufacturer, the RESPONSIBLE AUTHORITY must
                           confirm with the manufacturer that the proposed
                           method will not damage the instrument.

           7.2.1    Cleaning instructions
           e WADiana® Compact has been manufactured with the best quality materials.
           however, saline solutions and acid or alkaline solvents must be cleaned from
           the exterior surfaces before they produce any damage.
           e exterior surfaces should be periodically cleaned, but always with the
           equipment completely disconnected from the electric mains supply. Use a damp
           cloth with a mild detergent.
           e carrousel may be removed in order to clean it. It should be cleaned with a
           damp cloth and soap. Additionally, alcohol may be used to clean the area that has
           been in contact with samples.
           Additionally, with a cotton stick wet in distilled water, clean the higher side of the
           probe wash station inserting the cotton stick into the window placed in the
           frontal cover of the arm with the pipette probe. is windows is placed below the
           label of figure 2-1.

           7.2
3034072 Wadiana ES-EN:GRIFOLS   1/2/12   09:30   Página 89

             WADiana® Compact                                                       Maintenance

             e wash and waste bottles should also be removed from the equipment in order
             to be emptied and cleaned.

                                WARNING!
                                Take care of not leaking liquids into the
                                equipment openings.

                                WARNING!
                                The contents of the waste bottle should be
                                emptied into special containers provided for this
                                type of waste that must be eliminated in a
                                selective manner.

             e external wash of bottles should also be carried out with soap and water.

                                NOTE:
                                The front glass should always be cleaned with
                                mild and not abrasive products, in order to avoid
                                any scratching of the glass during the cleaning
                                process.

             7.2.2   Decontamination instructions
             e decontamination process of the equipment should be carried out monthly
             (see the maintenance plan) or whenever the equipment is moved from its
             working area.
             e decontamination process for the WADiana® Compact equipment is as
             follows:
                   1) Dispose of following solutions:
                            - 3500 ml of 0.5% Sodium hypochlorite solution.
                            - 5000 ml of reagent grade water.
                            - 100 ml of 70% ethyl alcohol.

                                                                                            7.3
3034072 Wadiana ES-EN:GRIFOLS   1/2/12   09:30   Página 90

           WADiana® Compact                                                    Maintenance

                 2)  fill the wash bottles A and B with the 0.5% Sodium hypochlorite
                     solution (1500 ml in each one). fill the waste bottle with 500 ml of
                     0.5% Sodium hypochlorite. Shake to decontaminate its inner.
                 3) Prime the system three times using the soware.
                 4) fill dilution station with 2.5 ml of 0.5% Sodium hypochlorite using
                     a pipette.
                 5) Wait 10 minutes.
                 6) Rinse and drain the bottles several times with reagent grade water in
                     order to eliminate any trace of Sodium hypochlorite.
                 7) fill wash bottles A and B with 1500 ml of reagent grade water each.
                     Select Rinse option on the program.
                 8) e equipment will automatically perform a 10 rinse cycles of the
                     entire hydraulic system using reagent grade water. Once they have
                     been finished, the program requests to drain solution from waste and
                     wash bottles and to replace for A and B solution. Select continue.
                 9) cleaning of dilutions station: clean the inner par of the dilutions
                     station, using a cotton stick wet with reagent grade water.
                 10) Switch the equipment off and unplug the electric mains cable. Probe
                     cleaning. follow next steps:
                           - move the arm until frontal le corner of the equipment.
                           - Drive manually the pinion placed in the higher part of the
                             arm, and low the probe until its maximum position.
                           - clean the probe external part with a cloth and 0.5% Sodium
                             hypochlorite solution.
                           - clean the probe external part with a cloth and reagent grade
                             water.
                           - Raise manually the probe until top position and turn back
                             once approximately.
                 11) clean the exterior of the equipment with a cloth and reagent grade
                     water. Decontaminate the exterior of the equipment with a cloth and
                     a solution of alcohol. is operation must be carried out when
                     dangerous substances are spilled on the equipment.

           7.4
3034072 Wadiana ES-EN:GRIFOLS   1/2/12   09:31   Página 91

             WADiana® Compact                                              Transport and storage

             8 TRANSPORT AND STORAGE

             8.1   Equipment storage
             If the WADiana® Compact must be stored for a long period of time, it is
             recommended to pack it as for transport.
             e environmental storage conditions should be as specified in section 3.1
             "Technical specifications"
             e space requirements for storing the equipment are as follows: Size: 1200 mm
             width x 750 mm depth x 920 mm height
             Weight: (87 + 35) = 122 Kg

                                CAUTION!
                                Use only the original packing material for
                                transporting the equipment.

                                WARNING!
                                Take care of decontaminating the equipment
                                before being transported.

             8.2   Unpacking the equipment
             In order to unpack the equipment, remove the packing material according to the
             following instructions:
                   1) Remove the wooden box, taking into account the screws that fix it
                         to the pallet.
                   2) Remove foam protections that protect the equipment.

             8.3   Placing the equipment in its operation position
             Before unpacking the WADiana® Compact, it should be placed on the floor with
             the pallet, as close as possible to where it is to be installed.
             here, it should be unpacked according to the instructions explained in the
             previous section and then it should be placed in the chosen place.

                                                                                            8.1
3034072 Wadiana ES-EN:GRIFOLS     1/2/12    09:31    Página 92

           WADiana® Compact                                                       Transport and storage

           Transporting the equipment requires various persons. hands will be inserted
           into the handles located at the lower part of the sides.
           Keeping the back erect, all sides should be lied at the same time in order to
           place the WADiana® Compact in the required site.

                          WARNING!
                          The weight of the equipment is considerable, so
                          it is advisable to strictly follow these instructions
                          for placing it into position.
                          It must be lifted by four persons, holding it in the
                          manner shown (hands in the handles and with
                          their backs erect and flexing the legs).

           8,2
3034072 Wadiana ES-EN:GRIFOLS   1/2/12   09:31    Página 93

             WADiana® Compact                                                         Equipment disposal

             9 EQUIPMENT DISPOSAL
             If the equipment is to be scrapped because it is no longer required for use, it
             must be first completely cleaned and all possible remains of sample and reagents
             eliminated. Once this has been done then it may be sent to an authorised centre
             for this type of scrap.

                                WARNING!
                                This instrument should only be disassembled by
                                authorised specialists.

                                CAUTION!
                                When the instrument is at the end of its useful
                                life, you must take into account all local in force
                                regulations to discard it.

             e WADiana® Compact is considered to be electronic waste. If in doubt, consult
             the necessary information with your Technical Service or your distributor.

                                                                                                     9.1
3034072 Wadiana ES-EN:GRIFOLS   1/2/12   09:31   Página 94
3034072 Wadiana ES-EN:GRIFOLS   1/2/12   09:31   Página 95

             WADiana® Compact                                                       Warranty

             10 WARRANTY
             e warranty conditions are set up in documents aside. contact your supplier in
             case of any doubt. e following parts are excluded from warranty:
                    •    RS-232 cable, mains cable and video cable.
                    •    Tubes and fittings.
                    •    Syringe.
                    •    Bottle.
                    •    Probe.
                    •    Waste card tray

                                                                                       10.1
3034072 Wadiana ES-EN:GRIFOLS   1/2/12   09:31   Página 96
modelo:               nº serie:                      fecha de instalación:
    Model:                Serial Number:                 Installation date:

                     servIcIos De mantenImIento realIzaDos
                        MAINTENANCE SERVICES CARRIED OUT
                                                                                                                                    WADiana® Compact
                                                                                                                                                                       3034072 Wadiana ES-EN:GRIFOLS

                                                                   tÉcnIco/autorIDaD
     fecha    accIón realIzaDa              tÉcnIco/operaDor          responsable
      DATE    WORK CARRIED OUT             TECHNICIAN/OPERATOR         TECHNICIAN/
                                                                                                                                                                       1/2/12

                                                                  RESPONSIBLE AUTHORITY
                                                                                                                                                                       09:31
                                                                                                                                                                       Página 97

                                                                                             MAINTENANCE SERVICES CARRIED OUT
                                                                                          SERVICIOS DE MANTENIMIENTO REALIZADOS /

I
                                                                                                                                    Maintenance services carried out
II
                     servIcIos De mantenImIento realIzaDos
                        MAINTENANCE SERVICES CARRIED OUT

                                                              tÉcnIco/autorIDaD
     fecha   accIón realIzaDa           tÉcnIco/operaDor         responsable
                                                                                     WADiana® Compact

      DATE   WORK CARRIED OUT          TECHNICIAN/OPERATOR        TECHNICIAN/
                                                             RESPONSIBLE AUTHORITY
                                                                                                                        3034072 Wadiana ES-EN:GRIFOLS
                                                                                                                        1/2/12
                                                                                                                        09:31
                                                                                                                        Página 98

                                                                                     Maintenance services carried out
You can also read