2 | Getinge AER Range ENDOSCOPE REPROCESSING – FAST AND ERROR-PROOF As the use of endoscopes increases, so does the risk of infections linked to endoscope reprocessing. This is indeed an area where “zero tolerance” towards cross-contamination must be maintained. And at Getinge, we are convinced that there’s only one way to do this. Every time we design and develop a new AER, Automated Endoscope Reprocessor, we need to minimize the risk of contamination. This range of AERs is no exception. We built it into the product, and into the workflow around the products. We applied a system approach, in the way that we always do at Getinge – the way of thinking that has made us the world leader in disinfection and sterilization. The Getinge range of AERs consists of three “error-proofing” machines – ED-FLOW, ED-FLOW SD and ED900. Each of them represent a breakthrough for a more all-embracing approach to infection control in endoscope reprocessing.
4 | Getinge AER Range TAKE CARE OF YOUR PATIENT WHILE WE HANDLE YOUR ENDOSCOPES Here are some of the main features and benefits: The fastest and most efficient Hands-free operation when loading Optimum traceability, thanks to the cycles. No other AER can run such and unloading endoscopes. You do RFID, operators and endoscopes are an extensive program complying with not have to touch any panel or button automatically stored and printed along national and international regulations, with dirty hands. Open the AER using with the cycle data. And the Getinge in such a short time – only 23* minutes! the foot pedal, let the RFID choose the software helps to manage all data. right cycle and the AER starts automatically. Two separate chambers in the The pass-through design of the The compact design of the ED900 Getinge AER range, the ED-FLOW is the Getinge ED-FLOW AER allows for a makes the AER easy to integrate in world’s first true pass-through AER with true physical barrier between soiled existing standard endoscopy suite two asynchronous chambers – so you and clean sides. Each chamber has department. Only 900 mm wide, you can have a faster, smarter, more versatile two doors, one for loading and the can fit it in between two normal lab and more efficient flow of flexible other for unloading the endoscopes. benches. endoscopes through your reprocessing department. * 29 minutes if a second wash phase is required by local regulations.
Getinge AER Range | 5 Unique handling of chemicals. The ED-FLOW SD brings first class Installation and service access are Aperlan Poka-Yoke Agent A & Agent B efficiency when it comes to endos- made easier on the ED-FLOW SD disinfectant containers can only be cope flow while offering high flexibility thanks to the wheels and the handle. placed in one way – the right one. Our regarding space constraints in perforating system leaves no exposure endoscopy suite. risk to operator whatsoever. ED900 is also fitted with four wheels to Endoscopes can be prepared on a tray Online access to the Getinge facilitate handling during installation on a work surface before being loaded connector database. This database is a and maintenance. into the ED-FLOW / ED-FLOW SD. The direct access to all the connection kits same tray can be used for transporta- and endoscope families that you can tion to the point of use and stored in the reprocess in you AER. Getinge FD8 drying cabinet.
6 | Getinge AER Range CUSTOMIZED TO YOUR NEEDS – USING THE SPACE YOU HAVE PASS-THOUGH CONCEPT Modern infection control is based on the barrier principle, a clear separation of dirty and clean areas. Getinge ED-FLOW AER – a true pass-through solution The Getinge ED-FLOW AER is a true barrier system, meant to separate the dirty and the clean areas as a physical barrier. Interlocked doors ensure that only scopes that have run through a complete and approved cycle can be unloaded from the clean side. If an error during the process, the AER will only open up on the dirty side. DIRT DE Y S I SI D AN E E CL Getinge ED-FLOW AER
Getinge AER Range | 7 SINGLE-DOOR CONCEPT Getinge ED-FLOW SD Getinge ED900 Productivity in endoscopy reprocessing area is key. The A small footprint associated to a large chamber and a Getinge ED-FLOW SD AER is the solution to combine high high level of performance is what any endoscopy center productivity and installation compatibility in an existing room. is looking for. And those features are precisely what Getinge ED900 AER offers. Getinge ED-FLOW SD AER Getinge ED900 AER
8 | Getinge AER Range LOAD, START AND UNLOAD WITHOUT TOUCHING Just open it with the pedal and let the radio-frequency sensor register the user and endoscope ID, and automatically launch the right cycle. Hands-free operation – it’s smart, smooth and failsafe. Getinge ED900 AER Getinge ED-FLOW SD AER Getinge ED-FLOW AER
Getinge AER Range | 9 Infection control is about seeing the whole picture and, as far as possible, ensuring the risk of human errors is eliminated. For example: how can one avoid the situation where a nurse touches a handle, a panel, a start-button or a barcode reader after holding a dirty endoscope and thus leaving micro-organisms waiting to be picked up when unloading the clean endoscope? The answer is: hands-free operation. The first part is basic: a foot pedal After the manual pre-cleaning, the operator presses the pedal to open the AER. No need to touch any handle nor button. After successful decontamination the door can only be opened using the pedal on the clean side. And the best part: RFID identification and automatic start When the operator has loaded the endoscope into the AER, its RFID tag is automatically identified by the machine’s RFID antenna (RFID = Radio-Frequency Identification). The operator also has a RFID tag for automatic user identification. When the foot pedal is pressed, the AER will close the lid/door and automatically choose the right cycle for that endoscope, based on the RFID tag information, and start. Smooth, simple and failsafe This procedure has several benefits. First, it is easy and time saving for the operator. No data to be entered, just load the endoscope and press the pedal. Secondly, it reduces the risk of human errors. Only the correct cycle for that particular endoscope can be used. The AER cannot be started or unloaded without recording the correct user information. It also reduces the risk of cross-contamination. No button to push to open or close the lid, select a cycle, enter user information, start the AER or unload the clean endoscope. It could not be simpler – or safer.
10 | Getinge AER Range DATA CAPTURING AND TOTAL TRACEABILITY – TAKE COMMAND OF YOUR ENDOSCOPES As a clinic or department using endoscopes, the responsibility is normally yours to ensure that important procedure data is captured and documented. Therefore, you will need an AER with a fail-safe traceability system. Ideally, an AER captures and stores data automatically and therefore eliminates risks of human error. With a Getinge AER you can select from two endoscope reprocessing solutions or a combination of the two depending on your requirements. T-DOC EndoCycle offers data capturing from Getinge AER machines while T-DOC EndoTrace gives you total traceability throughout the production cycle. With a combination of T-DOC EndoCycle and T-DOC EndoTrace you thus have the optimal solution to take command of your endoscopes. An AER that helps you ensure traceability of your endoscopes and you can focus on providing quality care while spending less time on paperwork. Exactly what you get with an AER from Getinge. Data Capturing in the endoscope reprocessing unit With T-DOC EndoCycle you can document and capture essential process parameters such as endoscope ID, User ID, selected AER machine number, program type and detergent/disinfectant exposure. T-DOC EndoCycle also provides first-level traceability by linking Patient ID and/or doctor to the disinfection process. In this way, the history of your endoscopes is documented. Complete control of your endoscopes with total traceability T-DOC EndoTrace offers you enhanced endoscope repro- cessing enabling you to handle all aspects of endoscope reprocessing management. You are ensured total traceability as T-DOC registers endoscopes and button valves throughout their life-span and links them to all processes, actions and people they encoun- ter. Thereby, you always have a documented record that the correct processes and procedures were followed. In addition, you always know where your endoscopes are when you need them.
Getinge AER Range | 11 Automatic data collection with RFID tags By using RFID tags, both endoscope and operator are automatically identified, so the correct ID information is collected. The AER control system records cycle number, date, endoscope ID, type of cycle, user ID, cycle start and stop time.
12 | Getinge AER Range AN EXTENSIVE PROGRAM COMPLETED IN ONLY 23 MINUTES* The standard program for the Getinge AERs features continuous ”leak tests”**, four flow tests and three final rinses. It’s been designed to meet all regulations, including the ones in countries where demands have increased following the emergence of prion diseases. No other machine can complete so many phases within such a short time. As a result, the Getinge AERs will complete a cycle, fully validated, in accordance with the EN ISO 15883-1 and EN ISO 15883-4 standards in only 23 minutes*. ED-FLOW , ED-FLOW SD & ED900 assure a quick and fail-safe reprocessing of flexible endoscope complying with output demand. On top of this, you can save time thanks to the smart ergonomic design of the AERs. Loading scopes is very easy, and connecting them is really fast. All the time you have a good overview of the chamber, which contributes further to a smooth and simple workflow. STANDARD CYCLE DESCRIPTION PERMANENT ”LEAK TESTS”** INITIAL LEAK TEST FLUSHING WASHING AND RINSING RINSING DISINFECTION FINAL RINSING PURGE WITH AIR CHANNEL PATENCY/CHANNEL IRRIGATION TESTS Initial flush phase Wash phase Extensive rinses Disinfection phase Triple rinses Removes any Ensures that all Every wash phase is The standard The final rinse uses pretreatment chemical proteins are removed. followed by a rinse, program features 0.1 µm filtered water and removes gross Optional 2nd washing plus an extra one – a 5 minutes minimum to guarantee the contamination. and rinsing phase can for complete removal contact time, perfor- disinfected status be programmed. of detergent before med at 37°C. of the endoscope. disinfection. Special program for clean endoscopes – saves time Programmable thermal self-disinfection program A shorter 15*** minutes disinfection cycle is available for The self-disinfection program uses thermal disinfection to processed endoscopes that have been stored too long to reduce risk of contamination. By pre-setting the program use without renewed reprocessing. To be used according for automatic start, you know that the AER is ready for use, to local regulations. for example in the morning when you arrive. * 29 minutes if a second wash phase is required by local regulations. ** Should the endoscope passes the automatic initial leak test, a continuous air overpressure is maintained to protect the endoscope’s internal components. ***15 minutes when only one chamber running. 17 minutes when 2 chambers running.
Getinge AER Range | 13 UNIQUE EXTRA SAFETY THANKS TO THE CHANNEL IRRIGATION SYSTEM Endoscopes are not like other medical instruments. Disinfecting them is more complicated due to the complexity of the different internal channels. How do you assure that these channels – the inside of which no one will ever see – have been completely high-level disinfected and are 100% safe to use on the next patient after each reprocessing cycle? How can you be completely sure that each channel is 100% functional and that there is no obstruction due to bio-film Normal pressure build-up threatening the scope’s performance? Everything works correctly and the flow is normal. There is only one way. The unique CVL system (Channel irrigation Verification Library), which measures each channel separately, and warns if there is the slightest deviation compared to predefined values. High pressure – CVL warns This is something that other AERs do not offer. And it is priceless The pressure is high but the flow through the channel is very low. for those who appreciate peace of mind when it comes to patient Possible cause: obstruction (due to bio-film build-up or damage). safety. Here is how it works: 1. The AER compares* the measured pressure to pre-defined values that have been determined through our partnership Low pressure – CVL warns The pressure is very low, still the water and chemicals seems to with the main manufacturers of endoscopes – in order to flow totally unhindered. Possible cause: the endoscope is not assure that the cleaning and disinfection of each channel is connected. correctly performed. 2. During operation, the AER automatically compares the flow of each channel of each endoscope with the known reference values. If there is a deviation in the flow rate during the cycle, As decontamination in an AER is the AER notices it and warns the user by means of an alarm a terminal/final process prior to use message. on a patient, you have to be absolutely sure that the disinfection has been This way, you know that continuous safety is always assured. 100% successful. Thanks to the CVL The CVL functions as a quality assurance, letting you feel confident system, you can rest assured. that everything works as it should on a day-to-day basis. * CVL availability is dependent on the endoscope design
14 | Getinge AER Range EASY TO USE WITH MOST ENDOSCOPES – CONNECTOR DATABASE ON THE WEB The Getinge Infection Control Group knows a thing or Easy to connect any type of endoscopes previously two about safe reprocessing. Being the world leader in identified disinfection and sterilisation, it is even tempting to claim The Getinge AERs identify the endoscope and display that we know more about it than anyone. help for the operator on the screen. Also each tube for So both you and the manufacturer of your endo- the connection of internal channels has a different colour scopes can rest assured – whatever the type or brand, a to ease the connection. Customised and skillfully Getinge AER is tested to provide full compatibility and engineered endoscope connection kits are available for efficacy. usual endoscope models. Extensive testing of different endoscopes Each Getinge AER is developed for and extensively tested with different types and brands of flexible endoscopes. They handle scopes for, amongst others, upper and lower GI endoscopy, cystoscopy**, hysteros- copy**, bronchoscopy and rhinolaringoscopy. * May vary from country to country. ** Tested according to local regulations. Page 1 of 1 Endoscope Database Page 1 of 1 Endoscope manu facture: Pentax WIYUYRE -YOKE AER Endoscope Database GETINGE POKA Endoscope name : l: bronchoscope FB-15P Endoscope mode GPY-PEN-A : Endoscope family no: 04 e Poka-Yoke Recip Karl Storz Endoscope manufacture: GETINGE POKA-YOKE AER Customer B Endoscope name: ENT 11101-RP Endoscope model: Endoscope family: GPY-STO-A Endoscope Database 01 Poka-Yoke Recipe no: Page 1 of 1 Getinge Endoscope Database Page 1 of 1 GETINGE POKA -YOKE AER Endoscope manu facture: Fujinon Endoscope name : GETINGE POKA-YOKE AER Endoscope manufacture: Olympus Endoscope mode 67789 l: Endoscope model: duodenoscope TJF-240 Endoscope family coloscope EC-25 : 0DL5 Endoscope family: GPY-OLY-I Poka-Yoke Recip GPY-FUJ-G e no: Poka-Yoke Recipe no: 18 11 GPY-SU-01 2 Suction GPY-B-06 LeakTest GPY-L-01 Biopsy L 3 GPY-L-04 L LeakTest 1 Biopsy GPY-B-04 2 Suction GPY-SU-01 2 Suction GPY-SU-01 3 Biopsy GPY-B-03 3 Biopsy 4 Water See air channel No image found GPY-B-03 5 Air GPY-WA-02 4 Water GPY-W-01 6 Auxilliary Channel GPY-AX-03 5 Air GPY-A-01 L LeakTest GPY-L-03 6 Auxilliary Chann el GPY-AX-01 O HandlePlug LFC-S-01 L HandlePlug GPY-L-02 O HandlePlug LFC-S-05 ... 2008-10-23 wToConnect.asp? owToConnect/printHo .webhotel.tripnet.se/H http://getingepokayoke 2008-10-23 /HowToConnect/printHowToConnect.asp?... http://getingepokayoke.webhotel.tripnet.se http://getingepokayoke .webhotel.tripnet.se/H owToConnect/printHo wToConnect.asp? http://getingepokayoke.webhotel.tripnet.se/QuickSearch/printQuickSearch.asp?ID_E... 2008-10-30 ... 2008-10-23
Getinge AER Range | 15 The rotating nozzles deliver the washing, disinfection and The endoscope is loaded into the Getinge ED-FLOW AER rinse fluids at a high pressure in the chamber and on the or the Getinge ED-FLOW SD on a loading tray. You can exterior of the endoscope. prepare the endoscope on the tray on a work surface and then easily carry it over to the AER. Every endoscope channel is individually connected to one The ED-FLOW AER features communication windows over of the six available snap-on connections, in order to clean each door, to allow visual contact between people on both and disinfect the internal channels of the endoscope. sides. A LED panel gives you information about the cycle status at The interlocking doors of ED-FLOW ensure that the a glance.* endoscope cannot be unloaded unless a complete process has been successfully carried out. Getinge ED900 AER features a unique design holder, that It is very easy to connect the channels to the swinging-arm makes it easier to load the endoscope. By putting some connections module of ED-FLOW and ED-FLOW SD: you space between the bottom of the chamber and the just swing the module towards you for easy access to the endoscope, the holder also ensures that the disinfectant connectors. comes in contact with all external surfaces of the scope. * Only available on Getinge ED-FLOW AER and Getinge ED-FLOW SD AER
16 | Getinge AER Range A SAFER WAY TO HANDLE DETERGENTS – NO EXPOSURE AT ALL We made our AERs extra easy to use in everyday work. And we’ve also simplified changing detergent and disinfectant containers. We have made it easier – and much safer. We made it impossible to make errors – and minimised any exposure to chemicals. High-efficiency detergent Each AER from the Getinge range uses the detergent Getinge Poka-Yoke DLC, which is an alkaline type detergent with well-documented efficiency for protein and biofilm removal. The 3-liters containers last for 60 cycles. APERLAN for best disinfection efficacy The disinfectant used by ED-FLOW, ED-FLOW SD and ED900, is the peracetic acid-based APERLAN Poka-Yoke, delivered in two separate 5 kg containers – Agent A and Agent B. The two agents are mixed directly inside the machine and last for about 85 cycles. APERLAN Poka-Yoke Agent A & Agent B is used as single shot, i.e. it is not recy- cled/reused Disinfectant containers can only be placed in one way – the right way Since the bottles of Agent A and B have different shapes, they can only be positioned in the place allocated for them. No room for human errors. The containers do not have to be opened The bottles of Agent A and B are pierced inside the AER. This means that the operator will not be exposed to any possible health-hazardous chemicals. Safer for the operator and no chemical fumes in the repro- cessing room. Warning when container levels are low The AERs feature a built-in storage space The level of detergent and disinfectant is constantly monitored by the control for the detergent and the disinfectant containers. system and can be displayed on the operator screen. The system warns The large double door makes it easy to access the containers and replace them. if levels are low – no risk of running out of chemicals during a cycle.
Getinge AER Range | 17
18 | Getinge AER Range THE WORLD’S FIRST AERS WITH TWO ASYNCHRONOUS CHAMBERS Getinge ED-FLOW AER and ED-FLOW SD are the Getinge ED-FLOW AER: built into the wall perfect solution for larger endoscopy departments where Getinge ED-FLOW AER is a true pass-through solution – the you may have to perform high numbers of procedures. They AER is placed into a wall to create a true physical barrier offer excellent throughput with their two separate chambers between soiled and clean sides. Loading and unloading in combined with short cycles. For larger reprocessing different rooms is definitely the preferred solution (whenever departments, it is of course also possible to install several possible) in order to minimize the risk of cross-contamination. AERs in a row. It has a very small footprint – a depth of only 400 mm on each side when fitted into a wall – and can be positioned in many ways in the reprocessing department.
Getinge AER Range | 19 Unique asynchronous chambers don’t have to wait until you have two scopes to reprocess With double chambers operating independently, you get a before launching the cycle. better workflow and greater flexibility. Just load the soiled With two separate asynchronous chambers you get a endoscope into one of the chambers as soon as it is ready faster, more versatile and more efficient flow of flexible for decontamination. When the next one arrives, you can endoscopes through your reprocessing department. Into load it directly into the second chamber without having to the bargain you get outstanding infection control and wait for the first endoscope’s cycle to finish, and start the compliance with all the latest standards to give you peace reprocessing. Unlike some other one-chamber AERs, you of mind.
20 | Getinge AER Range GETINGE ED900 AER – OFFERING UNIQUE BENEFITS FOR SMALL CLINICS Widest chamber on the market and easy connec- tion system Integrated and automatic dosing consumable system Wheels for easy handling and service Thanks to its compact design ED900 is very easy to install against a wall in your existing endoscopy room. Technical maintenance is quicker and effortless thanks to its four wheels.
Getinge AER Range | 21 Glass door for visual cycle verification Complete traceability RFID system. Built-in thermal printer User-friendly interface - touchscreen panel This AER offer the widest chamber from the market ”older brothers” Getinge ED-FLOW and Getinge ED-FLOW SD. Even big endoscope like echoendoscope can be easily and Complete embedded traceability systems with integrated securely reprocessed without having to suffer any physical printer allows to track and trace all the cycles information. CVL constraints whatsoever. system proves that every endoscope channel has been In terms of patient’s safety and quality level for endoscope properly irrigated whatever its complexity. Getinge endoscope reprocessing, Getinge ED900 AER offers the same features as its database makes connection to the ED900 very handy.
22 | Getinge AER Range ACCESSORIES FOR THE BEST POSSIBLE WORKFLOW Getinge offers everything you need to ensure the best possible hygienic workflow in your reprocessing department. From endoscope connector kits to furniture for a smooth workflow. Here are examples of accessories available. For more information, please visit www.getinge.com. 5 6 4 1 7 2 3
Getinge AER Range | 23 1. Pre-treatment unit 2. Chemical storage trolley 3. Waste trolley For manual pre-treatment of endo- For storage of 2+2 disinfectant contain- For general waste such as gloves, scopes before the process. Made of ers and 3 DLC-detergent containers. brushes etc, this trolley is positioned composite material. The trolley is also lockable to the under the pre-treatment unit for easy pre-treatment unit for safe storage. access. Foot-pedal opening. 4. Wall rail 5. Chart holder 6. Connector holder system Made of sturdy extruded aluminium, Mounted on the wall-rail, the swivel Also mounted on the wall-rail, the the wall-rail serves as a multi-purpose chart holder keeps instruction leaflets connector holder transfers clean connec- holder. Can be used to contain/ close at hand (connection charts, user tors back to the dirty side for storage conceal wiring, cables etc. instructions, etc.). and re-use. The connectors are safely and hygienically transferred in a practical disposable plastic bag. 7. Clean table The clean table serves as a worktop for assembly of processed flexible endo- scopes. Made of composite material.
24 | Getinge AER Range EASY INSTALLATION AND COST-SAVING SERVICE SOLUTIONS Getinge AERs have been design in such a way that they are very easy to install and service.We also provide you with all the technical and opera- tional training you might need to use your equipment on a daily basis. Training can be performed either at your premises or at the Lancer/ Getinge Academy. Validation of your AER according to the EN ISO 15883-4 standards is also available to order: Installation and Operational Testing (IOT); Perfor- mance Qualification (PQ) and routine test (routine test is also performed according to EN ISO 15883-1). Equipment you can rely on Getinge AERs are manufactured in our Center of Excellence in Toulouse. This site has been manufacturing automatic endoscopes reprocessors for 20 years. It has therefore a broad experience and a well-established expertise. We provide you with certified equipment ED900 , ED-FLOW and ED-FLOW SD are certified to the following norms amongst others: • European Machine directive 2006/42/EC and Medical device directives 93/42/EEC • EN ISO 15883-1 & EN ISO 15883-4 standards Our connection kits are certified MEDICAL DEVICE CLASS I. They have been developed so you can connect the main endoscopes of the majors manufacturer. Other test performed by an independent laboratory • Biocidal activity of the APERLAN Poka-Yoke • Bactericidal, fungicidal, mycobactericidal, virucidal, sporicidal according to EN or ISO standards on disinfectants • Bactericidal and sporicidal activity of the disinfectant according to EN ISO 15883-4 standards • Cleaning efficacy tests according to ISO 15883-4 • Endoscope disinfection cycle efficacy tests according to EN ISO 15883-4 standards • Self disinfection cycle efficacy tests according to EN ISO 15883-4 standards (including water treatment unit) * availability of services to be checked locally.
Getinge AER Range | 25 TECHNICAL DATA GETINGE ED900 AER GETINGE ED900 AER: GENERAL FEATURES: CONNECTION OF UTILITIES Number of endoscopes: 1 Electrical connections/consumption 230 V -1PH + N 50 Hz Blue-tinted glass lid ✓ Water supply Minimum softened water
26 | Getinge AER Range TECHNICAL DATA GETINGE ED-FLOW AER 1969 mm 1909 mm 1100 mm 1200 mm 942 mm GETINGE ED-FLOW AER: GENERAL FEATURES: CONNECTION OF UTILITIES Number of endoscopes: 2 endoscopes in 2 separate chambers. Electrical connections/consumption 400 V 3PH + T + N 50 Hz/60 Hz Glass doors, true pass-through for building into a wall ✓ Water supply Minimum softened water
Getinge AER Range | 27 TECHNICAL DATA GETINGE ED-FLOW SD AER 1909 mm 1909 mm 1100 mm 905 mm GETINGE ED-FLOW SD AER: GENERAL FEATURES: CONNECTION OF UTILITIES Number of endoscopes: 2 endoscopes in 2 separate chambers. Electrical connections/consumption 400 V 3PH + T + N 50 Hz/60 Hz Glass door ✓ Water supply Minimum softened water
1922 ENG Rev. 2014.09 · Göteborgstryckeriet · We reserve the right to make technical and construction changes. Getinge Infection Control is the world leading provider of solutions for sterile processing in the healthcare sector. We aim to ensure the highest quality and safety at the lowest total cost. We offer complete solutions for a seamless work-flow, reducing the risk of contamination while helping healthcare to increase efficiency. Getinge Infection Control AB P O Box 69 SE-305 05 Getinge SWEDEN Phone: +46 (0) 10 335 00 00 E-mail: info@getinge.com GETINGE GROUP is a leading global provider of products and systems that contribute to quality enhancement and cost efficiency within healthcare and life sciences. We operate under the three brands of ArjoHuntleigh, GETINGE and MAQUET. ArjoHuntleigh focuses on patient mobility and wound management solutions. GETINGE provides solutions for infection control within healthcare and contamination prevention within life sciences. MAQUET specializes in solutions, getinge.com therapies and products for surgical interventions, interventional cardiology and intensive care.