2 Cooker hood CPD - Technical manual CONTENT MAINTENANCE (FOR THE USER) Cleaning........................................................................................................... 3 Replacing of the low energy lamp........................................................ 3 General............................................................................................................. 3 Operating of CPDA and CPDJ....................................................................4 Operating of CPDB, CPDC, CPDG, CPDH, CPDK............................... 5 INSTALLATION (FOR INSTALLERS AND SERVICE PERSONNEL) Installation height ....................................................................................... 6 Main supply ................................................................................................... 6 General............................................................................................................. 6 CPDA..................................................................................................................7 CPDB.................................................................................................................. 8 CPDC ................................................................................................................ 8 CPDG ................................................................................................................ 9 CPDH .............................................................................................................. 10 CPDK .............................................................................................................. 10 CPDJ ................................................................................................................. 11 ELECTRICAL CONNECTIONS (FOR INSTALLERS AND SERVICE PERSONNEL) CPDG.........................................................................................................................12 ADJUSTMENT, COMMISSIONING (FOR INSTALLERS AND SERVICE PERSONNEL) CPD(A, B, C, G) - Basic ventilation ......................................................13 CPD(A, B, C, G) - Forced ventilation ...................................................14 CPD(H, K) - Basic ventilation .................................................................15 CPD(H, J, K,) - Forced ventilation ........................................................ 16 GENERAL Spare parts CPD(A, B, C, G, H, J, K)..............................................................17 Declaration of conformity.................................................................................18 Disposal of product and packaging materials....................................... 19 Cooker hoods CPDD and CPDL, see separate instruction. WARNING! THE DEVICE CAN BE USED BY CHILDREN FROM 8 YEARS UPWARDS AND PEOPLE (INCLUDING CHILDREN) WITH REDUCED PHYSICAL, SENSORY OR MENTAL CAPABILITIES, OR LACK OF EXPERIENCE AND KNOWLEDGE UNLESS THEY HAVE RECEIVED GUIDANCE OR INFORMATION ON HOW TO USE THE DEVICE SAFELY AND UNDERSTAND THE RISKS THAT CAN OCCUR. CHILDREN SHOULD NOT PLAY WITH THE APPLIANCE. CLEANING AND MAINTENANCE IS NOT CARRIED OUT BY CHILDREN WITHOUT SUPERVISION. FläktGroup DC-8757GB 20180426_R1 Specifications are subject to alteration without notice
Cooker hood CPD - Technical manual 3 MAINTENANCE CLEANING OF COOKER HOOD Do not use abrasive sponge or cloth. CLEANING OF GREASE FILTER Note! Do not use the cooker hood without grease filter fitted. 1 alt. 2 3 3 Check the grease filter every week. Clean if needed. REPLACING OF THE LOW ENERGY LAMP GENERAL There is a fire risk if cleaning is not carried out in accordance with the instructions. Accessible parts may become hot when used with cooking appliances. Do not flambé under the cooker hood. If the supply cord is damaged, it must be replaced by the 11 W/E14 manufacturer, its service agent or similarly qualified per- sons in order to avoid hazard. FläktGroup DC-8757GB 20180426_R1 Specifications are subject to alteration without notice
4 Cooker hood CPD - Technical manual MAINTENANCE OPERATING OF CPDA AND CPDJ Handle for boosting Lighting FläktGroup DC-8757GB 20180426_R1 Specifications are subject to alteration without notice
Cooker hood CPD - Technical manual 5 MAINTENANCE OPERATING OF CPDB, CPDC, CPDG, CPDH AND CPDK 2 1 MIN Handle for boosting Lighting Handle for fan speed 2 NORMAL 1 MIN 2 MAX 1 MIN 2 MIN 1 MIN FläktGroup DC-8757GB 20180426_R1 Specifications are subject to alteration without notice
6 Cooker hood CPD - Technical manual INSTALLATION (FOR INSTALLERS AND SERVICE PERSONNEL) INSTALLATION HEIGHT MAIN SUPPLY min 400 mm All cooker hoods has to be connected directly or indirectly via the heat recovery unit/exhaust fan to earth. If the supply cord is damaged, it must be replaced by the manu- facturer, its service agent or similarly qualified persons in order to avoid hazard. The distance between the stove and the lower edge of the cooker hood has to be at least 400 mm, recommended distance 500 mm. GENERAL When the cooker hood is located above a gas appliance, this dis- tance shall be at least 650 mm. If the instructions for installation The air must not be discharged into a flue that of the gas hob specify a greater distance, this has to be taken is used for exhausting fumes from appliances into account. burning gas or other fuels. Regulations concerning the discharge of air have to be fulfilled. FläktGroup DC-8757GB 20180426_R1 Specifications are subject to alteration without notice
Cooker hood CPD - Technical manual 7 INSTALLATION (FOR INSTALLERS AND SERVICE PERSONNEL) CPDA Intended for multiple-unit dwellings with a central extract air fan or a heat recovery unit. Suitable for both new production and replacement of older cooker hoods. INSTALLATION BETWEEN KITCHEN CABINETS a b 3 max 300 mm 2 1 min 500 mm INSTALLATION BENEATH KITCHEN CABINETS a b a a =700 a =600 255 415 a =500 205 200 365 100 5 4 205 365 100 max 300 mm 160 100 Ø 50 2 min 500 mm 12mm 1 3 FläktGroup DC-8757GB 20180426_R1 Specifications are subject to alteration without notice
8 Cooker hood CPD - Technical manual INSTALLATION (FOR INSTALLERS AND SERVICE PERSONNEL) CPDB Replacement hood for older exhaust air fan JBDD-aa with capacitor box, manufactured before 2007. a b JBDD-a JBDD-a (earlier a (earlier a version version ) ) CPCB Remove the old cooker hood. CPDC Replacement hood for older heat recovery unit RDKG without bypass (fits RDKG-a-1-c-d-1). a b 2 3 3.1 3.2 5 4 1 6 Remove the old It is important to seal the grommet by putting cooker hood. back the small piece of sealing material. FläktGroup DC-8757GB 20180426_R1 Specifications are subject to alteration without notice
Cooker hood CPD - Technical manual 9 INSTALLATION (FOR INSTALLERS AND SERVICE PERSONNEL) CPDG With transformer, fits for example the new JBDD and JBFG. (Fits JBDD-aa-1-2 but also as replacement cooker hood for controlling older exhaust air fans and units, for example JBDB, JBDC and RDAA.) INSTALLATION BENEATH KITCHEN CABINETS INSTALLATION BETWEEN KITCHEN CABINETS 3 RDKS 3 2 4 4.1 4.2 2 5 1 1 min 500 mm CONNECTION TO EXHAUST FAN JBDD, GENERATION 2 CONNECTION TO OTHER FANS For electrical installation, see wiring examples on page 12. JBDD 1 = Orange - Supply voltage 3 to fan 2 = Blue - Neutral 3 = Black - Phase 4 = Yellow/Green - Ground 3 2 2 1 1 FläktGroup DC-8757GB 20180426_R1 Specifications are subject to alteration without notice
10 Cooker hood CPD - Technical manual INSTALLATION (FOR INSTALLERS AND SERVICE PERSONNEL) CPDH Replacement hood for older heat recovery units RDKG with bypass. (Fits RDKG-a-2-c-d-1). a b 2 5 3 1 4 Remove the old cooker hood. CPDK For heat recovery unit RDKG. (Fits RDKG-a-b-c-d-2). a b 2 3 1 4 FläktGroup DC-8757GB 20180426_R1 Specifications are subject to alteration without notice
Cooker hood CPD - Technical manual 11 INSTALLATION (FOR INSTALLERS AND SERVICE PERSONNEL) CPDJ For heat recovery unit RDKR or RDKS. a b 3 RDKS RDKS 2 4 4.1 4.2 6 5 1 7 It is important to seal the grommet by putting back the small piece of sealing material. The picture illustrates a right hand unit. FläktGroup DC-8757GB 20180426_R1 Specifications are subject to alteration without notice
12 Cooker hood CPD - Technical manual ELECTRICAL CONNECTIONS (FOR INSTALLERS AND SERVICE PERSONNEL) CPDG Note! Electrical connections have to be made by authorized personnel. EXHAUST FAN JBDB EXHAUST FAN JBDC 1) Not for 1) Also for conversion kit JBDB1) conversion kit JBDC1) JBDB-99-05-0 JBDB-99-05-0 Blue White Yellow/Green Black Brown Yellow/Green Blue Black JBDA-99-031 2µF, not included JBDA-99-031 2µF, not included N N Supply 230V L Supply 230V Yellow/Green L Yellow/Green Orange Black Blue Orange Black Blue CPDG/CPTG CPDG/CPTG ROOF FAN JBFG HEAT RECOVERY UNIT RDAA RDAA JBFG 1 2 3 4 5 6 7 Blue Yellow/Green Brown N N Supply 230V Supply 230V L L Yellow/Green Yellow/Green Orange Orange Black Black Blue Blue CPDG/CPTG CPDG/CPTG FläktGroup DC-8757GB 20180426_R1 Specifications are subject to alteration without notice
Cooker hood CPD - Technical manual 13 ADJUSTMENT CPDA, CPDB, CPDC AND CPDG – BASICVENTILATION 30 + 1xC Pa a= 7,5 10 12,5 15 20 25 30 250 30 + 2xC 200 30 + 4xC Measuring pressure ∆pm, Pa 100 50 40 30 5 6 7 8 9 10 12 15 20 30 Air flow q l/s c a b ∆p FläktGroup DC-8757GB 20180426_R1 Specifications are subject to alteration without notice
14 Cooker hood CPD - Technical manual ADJUSTMENT CPDA, CPDB, CPDC AND CPDG – FORCED VENTILATION When adjusting the forced air flow the fan speed must be increased up to the forced flow. 11 b= 5 7 9 10 25 15 a = 25 10 15 25 10 15 25 200 a b 10 13 25 150 a 10 100 14 25 Measuring pressure ∆pm, Pa 50 40 30 20 10 20 30 40 50 80 Air flow q, l/s a b ∆p FläktGroup DC-8757GB 20180426_R1 Specifications are subject to alteration without notice
Cooker hood CPD - Technical manual 15 ADJUSTMENT CPDH AND CPDK – BASIC VENTILATION The basic air flow in the hood is adjusted by removing any number of plugs in the cover plate. 180 2 4 170 160 6 8 150 140 10 Measuring pressure ∆pm, Pa 130 120 110 100 90 80 70 60 50 40 30 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 Air flow q, l/s 2, 4, 6, 8 och 10 = number of open holes in the cover plate. 1 8 10 9 2 7 3 6 ∆p 4 5 Connection of the When forcing the air stream must be measured at both measure- measuring tube ment points (basic flow and forced flow). FläktGroup DC-8757GB 20180426_R1 Specifications are subject to alteration without notice
16 Cooker hood CPD - Technical manual ADJUSTMENT CPDH AND CPDK - FORCED VENTILATION Damper blade without basic flow valve (sealed damper blade) When adjusting the forced air flow the fan speed must be increased up to the forced flow. b=7 8 9 11 200 13 150 100 14 Measuring pressure ∆pm, Pa 15 50 40 30 20 10 20 30 40 50 80 Air flow q, l/s b ∆p FläktGroup DC-8757GB 20180426_R1 Specifications are subject to alteration without notice
Cooker hood CPD - Technical manual 17 SPARE PARTS CPDA, CPDB, CPDC, CPDG, CPDH, CPDJ AND CPDK 3 2 1 4 4 5 11 12 6 13 15 8 14 7 9 10 Cut the power before start working with the unit. All work has to be carried out by qualified personnel in order to avoid hazard. Intended for CPD... Pos No. Designation Description A B C G H J K M 1 25 CPDA-99-01 Handle x x x x x x x x 2 10 CPDA-99-02 Lightning switch x x x x x x x x 3 1 CPDA-99-03 Front board 1-handle, 500 mm x 3 1 CPDA-99-04 Front board 1-handle, 600 mm x x 3 1 CPDA-99-05 Front board 1-handle, 700 mm x x 3 1 CPDC-99-02 Front board 2-handles, 500 mm x x 3 1 CPDC-99-03 Front board 2-handles, 600 mm x x x x x x 3 1 CPDC-99-04 Front board 2-handles, 700 mm x x x 4 10+10 CPDA-99-07 Black plastic corners, right and left x x x x x x x x 5 1 CPCA-99-15 Timer with shaft: 600 mm (R, L), 700 mm (R) x x x x x x x Timer with shaft: 500 mm (M), 600 mm (M), 700 5 1 CPDA-99-10 x x x mm (M, L) 5 1 CPDJ-99-01 Timer w. shaft: 600, 700 mm (w. contact function) x 6 10 CPCA-99-09 Lamp socket x x x x x x x 6 10 CPDA-99-12 Lamp socket, transverse light x x x x x x x x 7 1 CPCA-99-12 Throttling device, complete x x x x 7 1 CPDH-99-02 Throttling device, complete (without basic flow) x x x x 8 25 BHGA-99-48 Plastic plugs x x x x x x 9 10 CPDA-99-06 Lamp protecting glass x x x x x x x x 10 1 CPCA-99-13 Grease filter x x x x x x x x 11 5 CPDC-99-01 Switch x x x x x x 12 1 CPDG-99-01 Transformer x x 13 1 CPDH-99-01 Time relay x 14 10 CPDA-99-15 Damper eccentric, 10-pack x x x x x x x x 15 10 CPDA-99-13 Damper gasket, 10-pack x x x x x x x x Pos 5. R = Rght, M = Middle, L = Left FläktGroup DC-8757GB 20180426_R1 Specifications are subject to alteration without notice
18 Cooker hood CPD - Technical manual DECLARATION OF CONFORMITY ENCLOSURE II A Declaration of Conformity In accordance with: EU Directive for Machinery, 2006/42/EC EU EMC Directive, 2014/30/EU EU RoHS Directive, 2011/65/EU Manufacturer FläktGroup Sweden AB Fläktgatan 1 551 84 Jönköping Herewith declares that: Product Type: Cooker Hood Manufacturer: FläktGroup Sweden AB Commercial name: CPD/A/B/C/D/G/H/J/K/L ( several versions / variants) The machine is designed and manufactured in accordance with the following standards, in relevant parts. EN ISO 12100 Safety of machinery – General principles for design- Risk assessment and risk reduction EN 60204-1 Safety of machinery; electrical equipment of machines; general requirements EN 60335-1 Household and similar electrical appliances - Safety - Part 1: General requirements EN 60335-2-31 Household and similar electrical appliances - Safety - Part 2: Particular requirements EN 61000-6-1 Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity for residential, commercial and light-industrial environments EN 61000-6-3 Emission standard for residential, commercial and light-industrial environments. EN 50106:2008 Safety of household and similar electrical appliances - Particular rules for routine tests referring to appliances under the scope of EN 60335-1 EN 62233:2008 Measurement methods for electromagnetic fields of household appliances and similar apparatus with regard to human exposure EN 50581:2012 Technical documentation for the assessment of electrical and electronic products with respect to the restriction of hazardous sustances A risk analysis has been made according to requirements of the Directive for Machinery. Authorized To prepare technical documentation: Ann-Sofie Andersson Design- R&D FläktGroup Sweden AB Fläktgatan 1 551 84 Jönköping The declaration applies only to the installation made according to FläktGroups instructions and assuming no changes made to the unit. Jönköping 2018-04-24 Magnus Nilsson, Quality Manager, FläktGroup Sweden AB, Jönköping FläktGroup Sweden AB Postal Address Street Address Telephone Telefax Reg. no: FläktGroup Sweden AB Fläktgatan 1 Nat 036 - 19 30 00 Nat 036 - 19 31 40 556239-2463 S-551 84 Jönköping Int +46 36 19 30 00 Int +46 36 19 31 40 Reg. office: Sweden Jönköping 8364GB_CPD Declaration of conformity(2A)201804 FläktGroup DC-8757GB 20180426_R1 Specifications are subject to alteration without notice
Cooker hood CPD - Technical manual 19 DISPOSAL OF PRODUCT AND PACKAGING MATERIALS Recycling should be made in accord- ance with local regulations. When the product is scrapped the following parts/ components/materials shall be sorted. Depending on what product it is may not all parts/components/materials be rep- resented. – Printed circuit boards, cables, batteries, motors, sensors etc. – Filters, except made of pure metal (in cooker hoods). – Packaging materials, such as cardboard, plastic and styrofoam. – The units casing may contain condense- or mineral wool insulation sandwiched between the inner and outer shell. – The remaining parts shall be sorted as metallic. – Lamps and fluorescent lights. See www.flaktwoods.com/ecodesign for recycling instructions. FläktGroup DC-8757GB 20180426_R1 Specifications are subject to alteration without notice
FG_DC_8757GB_CPD_IN-MA-CM-SP_20180426_R1 © Copyright 2018 FläktGroup J8013821-2301 WWW.FLAKTGROUP.COM CPD FläktGroup is the European market leader for smart and energy efficient Indoor Air and Critical Air solutions to support every application area. We offer our customers innovative technologies, high quality and outstanding performance supported by more than a century of accumulated industry experience. The widest product range in the market, and strong market presence in 65 countries worldwide, guarantee that we are always by your side, ready to deliver Excellence in Solutions. PRODUCT FUNCTIONS BY FLÄKTGROUP Air Treatment | Air Movement | Air Diffusion | Air Distribution | Air Filtration Air Management & ATD’s | Air Conditioning & Heating | Controls | Service » Learn more on www.flaktgroup.com or contact one of our offices