WHAT IS THE CHANGE? On the 1st of May 2019, the National Construction Code will introduce a new section titled ‘Condensation Management’ which includes an important change to the selection of wall wrap. The change will effect all Building Permits approved after the 1st of May 2019. All Building Permits approved using NCC2016 will not be affected by this change, and may use the wall wrap included in the original specification. The NCC changes to Volume 1 Part F6.2 and Volume 2 Part 3.8.7.2 will state that if a wall wrap is installed onto an external wall frame in BCA Climate Zone 6, 7 & 8, it is required to be vapour permeable. This change is mandatory for brick veneer and lightweight clad construction. WHY HAS THE NCC MADE THIS CHANGE? Better insulated and sealed homes perform well in cold climates but they need to release the water vapour accumulated inside as a result of everyday activities like heating, cooking & washing. V apour permeable wraps allow the release of water vapour from inside the home while preventing the entry of external water and air. WHAT DOES IT MEAN FOR YOU AND YOUR STATE? A detailed summary of the affected municipalities are shown by BCA Climate Zone on the following pages. In summary, any Building Permit for Class 1, 2 and 4 buildings approved after the 1st of May 2019 that includes a pliable building membrane on the external wall frame, must be vapour permeable if it is constructed in climate zones 6/7/8.
New South Wales & ACT LIST OF EFFECTED REGIONS The following lists include every municipality within New South Wales that is categorised WHEN WALL WRAP IS INSTALLED BEHIND BRICK V ENEER within BCA Climate Zone 6, 7 or 8. OR LIGHTWEIGHT CLAD, IN ACCORDANCE WITH NCC2019, IT WILL BE REQUIRED TO BE V APOUR If a wall wrap is specified in any Building PERMEABLE IN BCA CLIMATE ZONES 6, 7 & 8. Permit after the 1st of May 2019, it will be mandatory to use vapour permeable behind both Brick Veneer and Lightweight Clad in the climate zones listed below. CHANGES TO NSW & ACT New South Wales will be partially affected by the NCC 2019 NEW SOUTH WALES changes as a number of suburbs fall under the BCA (EXCLUDING SYDNEY URBAN AND CLIMATE ZONE climates 6, 7 and 8. All of the listed regions are classified as SURROUNDS) ‘Mild to Cool Temperate’ and there is a higher risk of Armidale 7 to 8 condensation when building in these areas. Bathurst 7 Bega Valley 6 Blayney 7 Blue Mountains 6 Eurobodalla 6 Glen Innes Severn 6/8 Goulburn Mulwaree 7 Hawkesbury 6 Lithgow 7 Mid Western 6 Muswellbrook 6 Oberon 7 to 8 Queanbeyan-Palerang 7 Shoalhaven 6 Singleton 6 Snowy Monaro 7 to 8 Snowy Valleys 7 to 8 Tenterfield 6 Upper Hunter 6 Upper Lachlan 7 Uralla 6 Walcha 6/8 LOCAL GOVERNMENT AREA CLIMATE ZONE Australian Capital Territory 7 to 8 SYDNEY SURROUNDS CLIMATE ZONE Blacktown 6 Camden 6 Campbelltown 6 Cumberland 6 Fairfield 6 Liverpool 6 Parramatta 6 Penrith 6 The Hills 6
Victoria LIST OF EFFECTED REGIONS The following lists include every municipality within Victoria that is categorised within BCA WHEN WALL WRAP IS INSTALLED BEHIND BRICK V ENEER Climate Zone 6, 7 or 8. OR LIGHTWEIGHT CLAD, IN ACCORDANCE WITH NCC2019, IT WILL BE REQUIRED TO BE V APOUR If a wall wrap is specified in any Building PERMEABLE IN BCA CLIMATE ZONES 6, 7 & 8. Permit after the 1st of May 2019, it will be mandatory to use vapour permeable behind both Brick Veneer and Lightweight CHANGES TO VIC Clad in the climate zones listed below. Victoria will be significantly affected by the NCC 2019 changes, as the majority of suburbs fall under the BCA climates 6, 7 and 8. REGIONAL MELBOURNE CLIMATE ZONE All of the listed regions are classified as ‘Mild to Cool Temperate Alpine 7 to 8 or Alpine’ and there is a much higher risk of condensation when Ararat 7 building in these areas. Ballarat 7 Bass Coast 6 Baw Baw 7 to 8 Benalla 6 Cardinia 6 Central Goldfields 6 Colac Otway 6 Corangamite 6 East Gippsland 6 to 8 Glenelg 6 Golden Plains 6 Greater Bendigo 6 Greater Geelong 6 Hepburn 7 Horsham 6 Hume 6 Indigo 6 La Trobe 6 Loddon 6 Macedon Ranges 7 Mansfield 7 to 8 Melton 6 MELBOURNE CLIMATE SURROUNDS ZONE Mitchell 6 Banyule 6 Moorabool 6 Bayside 6 Mornington Peninsula 6 Boroondara 6 Mount Alexander 7 Brimbank 6 Moyne 6 Casey 6 Darebin 6 Murrindindi 7 to 8 Docklands 6 Nillumbik 6 Frankston 6 Northern Grampians 6 Glen Eira 6 Pyrenees 7 Greater Dandenong 6 Hobson Bay 6 South Gippsland 6 Kingston 6 Southern Grampians 7 Knox 6 Strathbogie 6 Manningham 6 Surf Coast 6 Maribyrnong 6 Towong 7 to 8 Maroondah 6 Melbourne Surrounds 6 Wangaratta 7 Monash 6 Wellington 6 to 8 Moonee Valley 6 West Wimmera 6 Moreland 6 Whittlesea 6 Port Philip 6 Stonnington 6 Wodonga 6 Whitehorse 6 Wyndham 6 Yarra 6 Yarra Ranges 7
Tasmania LIST OF EFFECTED REGIONS The following lists include every municipality within Tasmania that is categorised within WHEN WALL WRAP IS INSTALLED BEHIND BRICK V ENEER BCA Climate Zone 6, 7 or 8. OR LIGHTWEIGHT CLAD, IN ACCORDANCE WITH NCC2019, IT WILL BE REQUIRED TO BE V APOUR If a wall wrap is specified in any Building PERMEABLE IN BCA CLIMATE ZONES 6, 7 & 8. Permit after the 1st of May 2019, it will be mandatory to use vapour permeable behind both Brick Veneer and Lightweight CHANGES TO TAS Clad in the climate zones listed below. Tasmania will be greatly affected by the NCC 2019 changes as all of the suburbs fall under the BCA climates 7 and 8. All of the listed regions are classified as ‘Cool Temperate to TASMANIA CLIMATE ZONE Alpine’ and there is a much higher risk of condensation when Break O'Day 7 building in these areas. Burnie 7 Central Coast 7 to 8 Central Highlands 7 to 8 Circular Head 7 Clarence 7 Derwent Valley 7 to 8 Dorset 7 to 8 Flinders Island 7 George Town 7 Glamorgan/Spring Bay 7 Glenorchy 7 to 8 Hobart 7 Huon Valley 7 to 8 Kentish 7 to 8 King Island 7 Kingsborough 7 La Trobe 7 Launceston 7 to 8 Meander Valley 7 to 8 Northern Midlands 7 to 8 Sorell 7 Southern Midlands 7 Tasman 7 Waratah/Wynyard 7 to 8 West Coast 7 to 8 West Tamar 7
South Australia & Western Australia LIST OF EFFECTED REGIONS The following lists include every municipality within SA and WA that is categorised within WHEN WALL WRAP IS INSTALLED BEHIND BRICK V ENEER BCA Climate Zone 6, 7 or 8. OR LIGHTWEIGHT CLAD, IN ACCORDANCE WITH NCC2019, IT WILL BE REQUIRED TO BE V APOUR If a wall wrap is specified in any Building PERMEABLE IN BCA CLIMATE ZONES 6, 7 & 8. Permit after the 1st of May 2019, it will be mandatory to use vapour permeable behind both Brick Veneer and Lightweight Clad in the climate zones CHANGES TO SA listed below. South Australia will be partially affected by the NCC 2019 changes as a number of suburbs fall under the BCA climate 6. All of the SOUTH AUSTRALIA CLIMATE ZONE listed regions are classified as ‘Mild Temperate’ and there is a Coorong District 6 higher risk of condensation when building in these areas. Goyder 5 to 6 Grant 6 Kangaroo Island 6 Karoonda / East Murray 6 Kingston 6 Mount Gambier 6 Murray bridge 6 Naracoorte & Lucindale 6 Northern Areas 5 to 6 Peterborough 6 Robe 6 Southern Mallee 6 Tatiara 6 Wattle Range 6 ADELAIDE SURROUNDS CLIMATE ZONE Adelaide Hills 6 Alexandrina 6 Barossa 5 to 6 Clare & Gilbert Valleys 6 Light 6 Mount Barker 6 CHANGES TO WA Victor 6 Western Australia will be partially affected by the NCC 2019 Victor Harbor 6 changes as a number of suburbs fall under the BCA climate 6. All Yankalilla 6 of the listed regions are classified as ‘Mild Temperate’ and there WESTERN AUSTRALIA CLIMATE ZONE is a higher risk of condensation when building in these areas. Albany 6 Cranbrook 6 Denmark 6 Esperance 5 to 6 Gnowangerup 6 Jerramungun 5 to 6 Manjimup 6 Plantagenet 6 Ravensthorpe 5 to 6 PERTH SURROUNDS CLIMATE ZONE Boyup Brook 6 Bridgetown Greenbushes 6 Broomehill / Tambellup 6 Donnybrook-Balingup 6 Kojonup 6
THE RISK O F COND ENSATIO N IN OTHER CLIMATE ZONE S CONDENSATION RISK IN TROPICAL BCA CLIMATE ZONE 1 BCA Climate Zone 1 is considered a tropical region, and CSR Bradford highly recommends the use of vapour barrier membranes, instead of vapour permeable products. This is due to the higher moisture level experienced in tropical regions increasing the risk of interstitial condensation when the inside of the building is air conditioned. For more information on Bradford Thermoseal vapour barriers, please visit bradfordinsulation.com.au. CONDENSATION RISK IN BCA CLIMATE ZONES 2 TO 5 The formation of condensation related mould growth in temperate Climate Zones is still a high risk if moisture is not managed correctly. If there is insufficient drying capacity within the wall system and vapour permeable membranes are not used, liquid water can form and may be absorbed into water sensitive materials resulting in rot or mould. The combination of vapour permeable membrane and wall cavity not only allows water vapour to escape the building envelope, but prevent condensation and wind driven rain coming into contact with water sensitive materials such as building frame or insulation. CONDENSATION RISK UNDER ROOFS Condensation is not only a damaging force inside walls, it can also be a serious issue under the roof assembly. The risk of condensation is caused when water vapour generated inside the home, from daily activities, rises up into the roof cavity and comes into contact with the underside of the cold roof assembly. At night when the roof cools, it can reach dew point and moist air can condense to liquid water on the underside of the tile or metal sheet. This water can drip back down onto the ceiling potentially damaging insulation, staining plasterboard, or even be absorbed by the timber frame leading to serious mould growth. This issue can develop regardless of climate zone and CSR Bradford highly recommend the use of a vapour permeable roof sarking under tiled roof construction. CSR Bradford highly recommends recommendsthe theuse useof ofvapour vapourpermeable permeable membranClad in BCA membranes behind Climate both Zones Brick 2 toand Veneer 5. Lightweight Clad in BCA Climate Zones 2 to 8
Vapour Permeable Wall Wrap & Roof Sarking Solutions Bradford™ Enviroseal™ ProctorWrap™ range of construction fabrics represent the latest in moisture control, air tightness and vapour permeable water tight membranes. These products are designed to reduce the risk of condensation forming on surfaces within the building envelope where it is undesirable. While allowing moisture (water vapour) to pass outward from the inside of the building, these sophisticated membranes prevent the entry of water and dust and air from the outside environment both during and after construction. ENVIROSEAL RW VAPOUR PERMEABLE WALL WRAP A Light* duty triple layered spunbond vapour permeable wall wrap ideal for minimising condensation risk. Bradford Enviroseal RW is suitable for use with brick, timber, steel, fibre cement (James Hardie™ sheeting products) and Hebel construction PRODUCT SPECIFICATION S WIDTH LENGTH M2 PER PRODUCT PRODUCT NAME WEIGHT (MM) (M) ROLL CODE Enviroseal RW 1500 30 45 4.6 167641 Enviroseal RW 1500 50 75 7.9 118153 Enviroseal RW-IT* 1500 50 75 7.9 165532 Enviroseal RW 2750 25 68.75 8.5 138628 Enviroseal RW 3000 25 75 9.5 155884 *RW-IT includes integrated tape release liners ENVIROSEAL CW VAPOUR PERMEABLE WALL WRAP Enviroseal ProctorWrap CW is a Light* Duty, triple layer spun bond vapour permeable wall wrap with a higher tensile strength and material gsm weight than RW making it suitable for use as a commerical grade wrap with brick, timber, steel, fibre cement (James Hardie™ sheeting products) and Hebel construction. PRODUCT SPECIFICATIONS WIDTH LENGTH M2 PER PRODUCT PRODUCT NAME WEIGHT (MM) (M) ROLL CODE Enviroseal CW 1500 50 75 10.3 114175 Enviroseal CW-IT 1500 50 75 11 134863 *CW-IT includes integrated tape release liners ENVIROSEAL HTS VAPOUR PERMEABLE ROOF SARKING A highly vapour permeable, medium duty roof sarking is ideal for use as either a high strength wall wrap or roof sarking. It is suitable for use under tiled, slate and metal roof applications. Enviroseal HTS is lightweight making it easy to install and reinforced with a high tensile scrim for improved durability. PRODUCT SPECIFICATIONS WIDTH LENGTH M2 PER PRODUCT PRODUCT NAME WEIGHT (MM) (M) ROLL CODE Enviroseal HTS 1500 30 45 8.2 185381 B0288 02/19