College Creek Lofts and Townhomes - City of Ames RFP, Baker Subdivision
←
→
Page content transcription
If your browser does not render page correctly, please read the page content below
TABLE OF CONTENTS PROPOSAL ALIGNMENT WITH SELECTION CRITERIA 3 DEVELOPER’S STATEMENT 6 ATTACHMENT A – DEVELOPMENT PLAN 10 BUILDING AND UNIT COUNT 12 BUILDING AND UNIT SIZE 12 SITE PLAN 13 BUILDING A FLOOR PLANS 14 BUILDING A UNIT PLANS 17 BUILDING A ELEVATIONS 23 BUILDING B FLOOR PLANS 25 BUILDING C FLOOR PLANS 26 TOWNHOME UNIT PLANS 27 BUILDING B AND C ELEVATIONS 29 ATTACHMENT B – ENERGY CONSERVATION AND GREEN BUILDING 31 SUMMARY OF ENERGY CONSERVATION AND GREEN BUILDING FEATURES 32 ATTACHMENT C – FINANCING PLAN 33 PROJECT PROFORMA – SOURCES AND USES 34 UNIT MIX AND INCOME 36 OPERATING EXPENSES 37 15 YEAR CASHFLOW 39 DETAILED CONSTRUCTION COST BREAKDOWN 40 INCENTIVE REQUESTS 41 ATTACHMENT D – EXPECTED LIHTC SUCCESS 42 DETAILED IFA SCORING 43 PREVIOUS IFA LIHTC AWARDS 46 ATTACHMENT E – TIMING 47 CONSTRUCTION SCHEDULE (PROPOSED TIMING OF IMPROVEMENTS) 48 ATTACHMENT F – MVAH PARTNERS CAPABILITY AND TRACK RECORD 49 MVAH PARTNERS RESUMES 50 REFERENCES 57 RECOMMENDATIONS 59 MVAH EXAMPLE PROJECTS 63 FINANCIAL CAPACITY – INCLUDING PIPELINE PROJECTS AND REO 66
Proposal Alignment with Selection Criteria Please use the following as a roadmap for where our proposal, College Creek Lofts and Townhomes, meets the City of Ames RFP Selection Criteria. The “Complete” column is utilized for us to self-score as well as to provide a tool for the reviewer to mark items complete. Also, please be advised this proposal, including information provided in all accompanying attachments, is firm for a period of not less than 60 days after the closing date of this request and through negotiations (signed statement is included in the Developer’s Statement). A. Competitive Requirement (page # coincides with PDF page number) 1. Applicant/Developer Capability and Track Record (30 points) City of Ames Criteria MVAH Partners Proposal Document Complete Location Page # MVAH City of Ames Applicant’s track record, • Developer’s Statement including whether the 6 applicant and/or development team has • Attachment F – MVAH successfully completed and/or operating a similar Partner’s Capability 49 type of LIHTC project. and Track Record Capacity to undertake new • Attachment F – MVAH or additional projects. Partner’s Capability 66 and Track Record – Financial Capability Ability to secure • Attachment F – MVAH construction financing. Partner’s Capability 66 and Track Record – Financial Capability Developer’s approach, plan • Developer’s Statement of work, recommended 6 schedules, and suggested responsibility assignments. • Attachment E – Timing 48 2. Quality of References (20 points) City of Ames Criteria MVAH Partners Proposal Document Complete Location Page # MVAH City of Ames Qualification and experience • Attachment F – MVAH in providing the requested Partner’s Capability 49 development as exemplified and Track Record 9100 Centre Pointe Dr. Suite 210 West Chester, OH 45069 (513)-964-1140
by past projects and client • Attachment D – contracts. Expected LIHTC 43 Success 3. Housing variety and architectural styles City of Ames Criteria MVAH Partners Proposal Document Complete Location Page # MVAH City of Ames Housing variety and • Developer’s architectural styles Statement 6 • Attachment A – Development Plan 10 4. Percentage of Affordable Housing Units City of Ames Criteria MVAH Partners Proposal Document Complete Location Page # MVAH City of Ames Percentage of Affordable • Attachment C – Housing Units Financing Plan, Unit Mix/Income 36 (50 total units – 45 LIHTC and 5 Market Rate). 5. Property Management Experience City of Ames Criteria MVAH Partners Proposal Document Complete Location Page # MVAH City of Ames Number of units managed • Attachment F – MVAH Partner’s Capability and Track Record. This information is included 66 in the Financial Capacity portion of Attachment F. Years of Experience • Attachment F – MVAH Partner’s Capability and 50 Track Record. Number of affordable units • Attachment F – MVAH managed and performance Partner’s Capability and 66 record Track Record. 9100 Centre Pointe Dr. Suite 210 West Chester, OH 45069 (513)-964-1140
Familiarity of the various • Attachment F – MVAH funding sources for housing Partner’s Capability and development and rental Track Record. This subsidies. information is included 66 in the Financial Capacity portion of Attachment E. 6. Feasibility (pro-forma including project funding sources) City of Ames Criteria MVAH Partners Proposal Document Complete Location Page # MVAH City of Ames Pro-forma including project • Attachment C – funding sources Financing Plan, Sources 33 and Uses 9100 Centre Pointe Dr. Suite 210 West Chester, OH 45069 (513)-964-1140
September 10, 2020 Ms. Karen Server City of Ames Purchasing Division (1st Floor), City Hall PO 811 Ames, IA 50010 RE: Request for Proposals for Low-Income Housing Tax Credit Developers in Partnership with the City of Ames – Developer’s Statement Dear Karen: MVAH Partners is pleased to submit a proposal to partner with the City of Ames for the construction of College Creek Lofts and Townhomes, a low-income rental housing development on the 2.78-acre site in the Baker Subdivision. Our team has extensive experience leveraging the Iowa Finance Authority’s (IFA) Low-Income Housing Tax Credit (LIHTC) program to create high quality, visually appealing and operationally sustainable affordable housing. In the past eight years, IFA has awarded MVAH Partners 12 projects (including two in 2020 and one in 2019) for a total of $98,571,430 in housing tax credits to create 606 units of safe, affordable housing for Iowa residents. The MVAH portfolio in Iowa operates at an average of 97% occupancy level. We are excited to provide the following proposal for the opportunity to partner with the City of Ames to meet your goals and priorities for the Baker Subdivision. Developer’s Statement Development Plan Our team put a lot of thought to the site layout including identifying the building size, type and placement on the site which we believe will be best for future residents as well as the Baker Subdivision and City of Ames. We have carefully reviewed the site’s pros and cons and come up with a plan that will maximize the number of units and points on the IFA QAP by building a retaining wall at the south end of the property. Unless we receive a setback variance, we will have to alter the topography of the site to achieve our goals, but we will install hardpipe storm water drainage to make sure it has no impact on the environment or neighbors. Our proposed site plan is also designed with the regional geothermal system in mind. We will be able to size separate systems for the 3-story building and the townhomes to maximize efficiency. We look forward to harnessing the potential energy savings to offer our residents not only affordable rents, but significantly reduced energy bills. It is a rare opportunity for a workforce development to be able to include such cutting-edge technology, but we are always looking for the right project to implement it. In addition, our plan includes the following amenities to best meet the needs of potential residents: • Free internet service for residents • An on-site playground • 360-degree interior and exterior security camera system, including hallways 9100 Centre Pointe Dr. Suite 210 West Chester, OH 45069 (513)-964-1140
• Fitness room • Computer room with internet access • In unit washer and dryer • Ceiling fans in every bedroom • On-site management • Community room • Accessible and adaptable ADA units Attachment A includes plans and additional development plan information. Energy Conservation and Green Building Features MVAH is committed to energy conservation and environmental stewardship throughout our portfolio. Nearly all of our new developments, and every MVAH project in Iowa, achieve EnergyStar Certification and Home Energy Rating System (HERS) of 62 or less, making them among the most efficient new construction buildings in the country. This project will meet exceed or exceed those expectations, as well. A few additional items of note are listed below. • All units are held to strict air sealing and insulation installation procedures and will be inspected by the HERS Rater. • All interior paints and primers used in the buildings will comply with Green Seal standards for low VOC limits. • All adhesives used will comply with Rule 1168 of the South Coast Air Quality Management District. • All of the carpeting used will be labeled with the Carpet & Rug Institute (CRI) Green Label. • All other hardsurface flooring will be FloorScore certified products. • All plumbing fixtures will be WaterSense labeled demonstrating the use of low-flow fixtures throughout. • The exterior envelope will include such features as continuous insulated sheathing, high R-value walls and roof, and Energy Star certified windows and doors. All of which contribute to the overall HERS index and Energy Star certification for the building. Attachment B includes additional information on energy conservation and green building features. Financing Plan Our proposed financing plan includes the following: Source Amount Comments First Mortgage $2,562,806 A conventional first mortgage, lender TBD. City of Ames HOME $400,000 LIHTC Equity $7,307,269 Pricing at $0.87 GP Equity $100 Deferred Developer Fee $127,198 Repaid in Year 7 – compliant with IFA QAP guidelines. Total $10,397,373 Construction Loan $7,570,942 Lender TBD 9100 Centre Pointe Dr. Suite 210 West Chester, OH 45069 (513)-964-1140
Please see Attachment C for our project proforma and more detailed information. Expected Success for LIHTC Application As demonstrated, MVAH has been very successful in both applying for and receiving LIHTC from IFA. We are confident we have the expertise and strategic approach to submit another successful application. Our self-score reflects a competitive score of 155 points, which is the cut-off score for awarded applications in the General Pool in 2020 (With the sole exception of one application scoring 148 and winning an award. The application won the award primarily because it received such a small allocation of LIHTC). Please reference Attachment D for anticipated scoring as well as a more detailed explanation. Goals 1. To provide workforce housing in the Baker Subdivision and the City at large via a partnership with the City of Ames. 2. Create an affordable housing community that balances maximizing the unit count using the land available with maximizing LIHTC scoring as outlined in the IFA 2020-2021 QAP. 3. Create an affordable housing product that integrates seamlessly to the surrounding subdivision and broader community. 4. Create new housing options marketable to families while meeting workforce housing needs in the City of Ames community. Timeline Action Deadline Submit Application to the City of Ames September 11, 2020 Submit Application to IFA March 10, 2021 Receive IFA LIHTC Award August 2021 Project Closing March 31, 2022 Construction Start April 1, 2022 Construction Substantial Completion June 1, 2023 Qualified Occupancy December 31, 2023 Please see Attachment E for a more detailed construction schedule including proposed timing of improvements and completion of improvements for the site. Partners and Members of the Development Team Developer – MVAH Development Architect – BDCL Architect Property Manager – MVAH Partners General Contractor – Koester or another GC approved by the Developer Investor – To be determined Construction Lender – To be determined Perm Lender – To be determined 9100 Centre Pointe Dr. Suite 210 West Chester, OH 45069 (513)-964-1140
ATTACHMENT A—DEVELOPMENT PLAN CITY OF AMES RFP Attachment A includes the following: • Development Plans including a conceptual site layout that identifies building size and locations, access point, parking, landscaping, and storm water. • Representative architectural elevations and floor plans. • Summary of plan types for total square footage, number of bedrooms, number and type of bathrooms, and square footage of any unfinished areas.
PROJECT TEAM: DRAWING INDEX: DEVELOPER: MVAH PARTNERS LLC 00 COVER SHEET 9100 CENTRE POINTE DRIVE, SUITE 210 WEST CHESTER, OHIO 45069 01 BUILDING & SITE DATA (513) 964-1140 02 SITE PLAN ARCHITECT OF RECORD: BDCL ARCHITECTS, PC 03 BUILDING A - FIRST FLOOR PLAN 9100 CENTRE POINTE DRIVE, SUITE 210 04 BUILDING A - SECOND FLOOR PLAN WEST CHESTER, OHIO 45069 05 BUILDING A - THIRD FLOOR PLAN (513) 964-1154 06 2 BEDROOM TYPE 2A ACCESSIBLE - UNIT PLAN 07 2 BEDROOM TYPE 2A - UNIT PLAN 08 2 BEDROOM TYPE 2B / 2C - UNIT PLAN 09 3 BEDROOM TYPE 3A ACCESSIBLE - UNIT PLAN 10 3 BEDROOM TYPE 3A - UNIT PLAN 11 3 BEDROOM TYPE 3B / 3C - UNIT PLAN 12 BUILDING A - BUILDING ELEVATIONS 13 BUILDING A - BUILDING ELEVATIONS 14 BUILDING B - FLOOR PLANS 15 BUILDING C - FLOOR PLANS 16 3 BEDROOM TYPE 3A TOWNHOME - UNIT PLAN 17 3 BEDROOM TYPE 3B / 3C TOWNHOME - UNIT PLAN 18 BUILDING B & C - BUILDING ELEVATIONS 19 PROJECT RENDERING OVERALL UNIT COUNT UNIT TYPE AMOUNT USED 2 BED / 2 BATH UNITS 24 3 BED / 2 BATH UNITS 12 3 BED / 2 BATH TOWNHOME UNITS 14 TOTAL 50 COLLEGE CREEK LOFTS & TOWNHOMES 09.10.20 ames, iowa cover sheet - 00 © 2019 MVAH Development LLC
BUILDING & UNIT COUNT BUILDING TYPE AMOUNT USED UNIT TYPES IN BUILDING 2 BED / 2 BED / 2 BED / 2 BED / 3 BED / 3 BED / 3 BED / 3 BED / 3 BED / 3 BED / 3 BED / TOTAL 2 BATH 2 BATH 2 BATH 2 BATH 2 BATH 2 BATH 2 BATH 2 BATH 2 BATH 2 BATH 2 BATH UNITS TYPE 2A TYPE 2A TYPE 2B TYPE 2C TYPE 3A TYPE 3A TYPE 3B TYPE 3C TYPE 3A TYPE 3B TYPE 3C ACC S&H ACC S&H TOWNHOME TOWNHOME TOWNHOME A 1 3 4 16 1 2 3 6 1 0 0 0 36 B 1 0 0 0 0 0 0 0 0 1 5 0 6 B2 1 0 0 0 0 0 0 0 0 1 6 1 8 TOTAL UNITS BY TYPE 3 4 16 1 2 3 6 1 2 11 1 50 UNIT SIZE & COUNT BUILDING 'A' SIZE BUILDING 'B' SIZE UNIT TYPE NET S.F. GROSS S.F. AMOUNT USED FLOOR LEVEL GROSS S.F. FLOOR LEVEL GROSS S.F. 2 BED / 2 BATH - TYPE 2A ACCESSIBLE 869 S.F. 947 S.F. 3 FIRST FLOOR 15,995 FIRST FLOOR 4,698 2 BED / 2 BATH - TYPE 2A 869 S.F. 947 S.F. 4 SECOND FLOOR 15,932 SECOND FLOOR 3,059 2 BED / 2 BATH - TYPE 2B 869 S.F. 947 S.F. 16 THIRD FLOOR 15,932 2 BED / 2 BATH SIGHT & HEARING - TYPE 2C 869 S.F. 947 S.F. 1 OVERALL BUILDING (ALL FLOORS) 7,757 3 BED / 2 BATH - TYPE 3A ACCESSIBLE 1081 S.F. 1185 S.F. 2 OVERALL BUILDING (ALL FLOORS) 47,859 3 BED / 2 BATH - TYPE 3A 1081 S.F. 1185 S.F. 3 3 BED / 2 BATH - TYPE 3B 1081 S.F. 1185 S.F. 6 BUILDING 'C' SIZE 3 BED / 2 BATH SIGHT & HEARING - TYPE 3C 1081 S.F. 1185 S.F. 1 FLOOR LEVEL GROSS S.F. 3 BED / 2 BATH - TYPE 3A TOWNHOME 1222 S.F. 1299 S.F. 2 FIRST FLOOR 6,043 3 BED / 2 BATH - TYPE 3B TOWNHOME 1198 S.F. 1282 S.F. 11 SECOND FLOOR 4,279 3 BED / 2 BATH SIGHT & HEARING - TYPE 3C TOWNHOME 1198 S.F. 1282 S.F. 1 OVERALL BUILDING (ALL FLOORS) 10,322 TOTAL 50 COLLEGE CREEK LOFTS & TOWNHOMES 09.10.20 ames, iowa building & site data - 01 © 2019 MVAH Development LLC
PROPOSED UNIT MIX: 2 BEDROOM / 2 BATH - 24 UNITS 3 BEDROOM / 2 BATH - 12 UNITS MONUMENT 3 BEDROOM / 2 BATH TOWNHOMES - 14 UNITS SIGN TRIPP TOTAL - 50 UNITS STRE ET PROP ERTY BUILDING A - 3 STORY BUILDING LINE BUILDINGS B & C - 2 STORY TOWNHOMES 25'-0" FRON T YAR D SE TBAC K SITE PARKING = REQUIRED 10 126 TOTAL PARKING SPACES 9 PROVIDED 8 TOWNHOMES 126 TOTAL PARKING SPACES BUILDING C (INCLUDES 6 ACCESSIBLE SPACES) SOUTH WILMOUTH AVENUE 11 11 10 DEVELOPMENT WILL BE PROVIDED WITH THE FOLLOWING AT A 9 MINIMUM: 10 1. VIDEO SECURITY SYSTEM SHALL RECORD ACTIVITY ACROSS 10'-0" SIDE YARD SETBACK PROPERTY LINE ENTIRE SITE INCLUDING PARKING AREAS, STAIRWAYS, PROPERTY LINE BUILDING A ELEVATORS, HALLWAYS AND ENTRANCES TO NON-TENANT 36 UNITS SPACES. CAMERAS IN CORRIDORS SHALL BE PLACED IN SUCH A WAY THAT ALL UNIT ENTRANCES ARE COVERED. 10'-0" SIDE YARD SETBACK 2. TWO BIKE RACKS SHALL BE PROVIDED AT EITHER END OF THE 10 10 BUILDING. 6 TOWNHOMES 10 3. A "NON-SMOKING" POLICY SHALL BE IMPLEMENTED AND BUILDING B 11 ENFORCED. 13 4. ADEQUATE SITE LIGHTING SHALL BE PROVIDED TO ENSURE SAFE AND SECURE TRAVEL FROM PARKING AREAS. 5. CONCRETE SIDEWALKS SHALL BE PROVIDED TO EACH ENTRANCE DOOR. LINE OF NEW UNDERGROUND STORM PIPING 2 PLAYGROUND LINE OF NEW SITE RETAINING WALL PROPE RTY LIN E site plan 1" = 60'-0" 25'-0" REAR YARD SETBACK PROPERTY LINE 0 30 60 120 180 COLLEGE CREEK LOFTS & TOWNHOMES 09.10.20 ames, iowa site plan - 02 © 2019 MVAH Development LLC
BUILDING WILL BE PROVIDED WITH THE FOLLOWING AT A MINIMUM: 1. COMMUNITY ROOM SHALL BE 20 SQ FT PER UNIT UP TO THE FIRST 40 UNITS. 2. A MINIMUM OF ONE 5' ADA COMPLIANT ROLL-IN SHOWER PER 20 UNITS SHALL BE PROVIDED. UNITS SHALL BE DISPERSED THROUGHOUT THE BUILDING. 3. ENTRANCE SHALL HAVE A FOYER (VESTIBULE) WITH REMOTE SECURITY AND INTERCOM SYSTEM TO EACH UNIT. 4. WATER CONSERVING MEASURES SHALL BE PROVIDED, INCLUDING HIGH-EFFICIENCY WATERSENSE TOILETS THAT USE 1.28 GALLONS PER FLUSH OR LESS, FAUCET AERATORS THAT USE 1.5 GALLONS PER MINUTE OR LESS IN KITCHENS AND 1.0 GALLONS PER MINUTE IN BATHROOMS, SHOWERHEADS THAT USE 1.5 GALLONS PER MINUTE OR LESS. 5. A PASSIVE RADON SYSTEM SHALL BE PROVIDED. 6. A MINIMUM OF TWO PERCENT (2%) OF ALL UNITS SUPPLIED SHALL BE ADAPTED FOR HEARING AND VISION IMPAIRMENTS AS UNITS WITH ACCESSIBLE COMMUNICATIONS FEATURES. 7. BUILDING DESIGN WILL COMPLY WITH IOWA FINANCE AGENCY 2021 QAP APPENDIX J BUILDING STANDARDS. FD FD FD 2BR FD 3BR FD 3BR 2BR TYPE 2BR TYPE TYPE TYPE 2A TYPE 3A NEEUQ QUEEN QUEEN QUEEN QUEEN TV 3A TV 2B ACCESS TV TV 2B TV ACCESS NEEUQ QUEEN QUEEN QUEEN QUEEN MECH. STAIR MAINT. STAIR NEEUQ QUEEN COMMUNITY FD ROOM FD FD M.W. FD FD TV ELEV. REF. DW MW MW MW MW MW MW MW MW MW WM MEN'S WOMEN FD MECH. FD FD DF FD LOBBY FITNESS QUEEN NEEUQ STOR 3BR TYPE 2BR 2BR 2BR 3BR QUEEN QUEEN QUEEN QUEEN NEEUQ TV TV TV TV VT QUEEN QUEEN QUEEN 3A TYPE TYPE TYPE TYPE QUEEN NEEUQ ACCESS 2A OFFICE 2A 2B 3B FD FD FD FD DF first floor plan 1"=20'-0" COLLEGE CREEK LOFTS & TOWNHOMES 09.10.20 ames, iowa building A - first floor plan - 03 © 2019 MVAH Development LLC
BUILDING WILL BE PROVIDED WITH THE FOLLOWING AT A MINIMUM: 1. COMMUNITY ROOM SHALL BE 20 SQ FT PER UNIT UP TO THE FIRST 40 UNITS. 2. A MINIMUM OF ONE 5' ADA COMPLIANT ROLL-IN SHOWER PER 20 UNITS SHALL BE PROVIDED. UNITS SHALL BE DISPERSED THROUGHOUT THE BUILDING. 3. ENTRANCE SHALL HAVE A FOYER (VESTIBULE) WITH REMOTE SECURITY AND INTERCOM SYSTEM TO EACH UNIT. 4. WATER CONSERVING MEASURES SHALL BE PROVIDED, INCLUDING HIGH-EFFICIENCY WATERSENSE TOILETS THAT USE 1.28 GALLONS PER FLUSH OR LESS, FAUCET AERATORS THAT USE 1.5 GALLONS PER MINUTE OR LESS IN KITCHENS AND 1.0 GALLONS PER MINUTE IN BATHROOMS, SHOWERHEADS THAT USE 1.5 GALLONS PER MINUTE OR LESS. 5. A PASSIVE RADON SYSTEM SHALL BE PROVIDED. 6. A MINIMUM OF TWO PERCENT (2%) OF ALL UNITS SUPPLIED SHALL BE ADAPTED FOR HEARING AND VISION IMPAIRMENTS AS UNITS WITH ACCESSIBLE COMMUNICATIONS FEATURES. 7. BUILDING DESIGN WILL COMPLY WITH IOWA FINANCE AGENCY 2021 QAP APPENDIX J BUILDING STANDARDS. FD FD FD FD 2BR FD FD 3BR 2BR 2BR TYPE 2BR 3BR TYPE TYPE TYPE 2A TYPE TYPE NEEUQ QUEEN QUEEN QUEEN QUEEN QUEEN TV 3A TV 2B TV 2B ACCESS TV TV 2B TV 3B NEEUQ QUEEN QUEEN QUEEN QUEEN QUEEN MECH./ MAINT. STAIR STAIR NEEUQ QUEEN FD COMP FD FD FD FD ROOM FD ELEV. MW MW MW MW MW MW MW MW MW MW MW MW WM FD FD FD FD FD FD DF QUEEN NEEUQ 3BR 2BR 2BR 2BR 2BR 2BR 3BR QUEEN QUEEN QUEEN QUEEN QUEEN QUEEN NEEUQ TV TV TV TV TV TV VT QUEEN QUEEN QUEEN QUEEN QUEEN TYPE TYPE TYPE TYPE TYPE TYPE TYPE QUEEN NEEUQ 3B 2B 2B 2B 2A 2B 3B FD FD FD FD FD DF FD second floor plan 1"=20'-0" COLLEGE CREEK LOFTS & TOWNHOMES 09.10.20 ames, iowa building A - second floor plan - 04 © 2019 MVAH Development LLC
BUILDING WILL BE PROVIDED WITH THE FOLLOWING AT A MINIMUM: 1. COMMUNITY ROOM SHALL BE 20 SQ FT PER UNIT UP TO THE FIRST 40 UNITS. 2. A MINIMUM OF ONE 5' ADA COMPLIANT ROLL-IN SHOWER PER 20 UNITS SHALL BE PROVIDED. UNITS SHALL BE DISPERSED THROUGHOUT THE BUILDING. 3. ENTRANCE SHALL HAVE A FOYER (VESTIBULE) WITH REMOTE SECURITY AND INTERCOM SYSTEM TO EACH UNIT. 4. WATER CONSERVING MEASURES SHALL BE PROVIDED, INCLUDING HIGH-EFFICIENCY WATERSENSE TOILETS THAT USE 1.28 GALLONS PER FLUSH OR LESS, FAUCET AERATORS THAT USE 1.5 GALLONS PER MINUTE OR LESS IN KITCHENS AND 1.0 GALLONS PER MINUTE IN BATHROOMS, SHOWERHEADS THAT USE 1.5 GALLONS PER MINUTE OR LESS. 5. A PASSIVE RADON SYSTEM SHALL BE PROVIDED. 6. A MINIMUM OF TWO PERCENT (2%) OF ALL UNITS SUPPLIED SHALL BE ADAPTED FOR HEARING AND VISION IMPAIRMENTS AS UNITS WITH ACCESSIBLE COMMUNICATIONS FEATURES. 7. BUILDING DESIGN WILL COMPLY WITH IOWA FINANCE AGENCY 2021 QAP APPENDIX J BUILDING STANDARDS. FD FD FD FD 2BR FD FD 3BR 2BR 2BR TYPE 2BR 3BR TYPE TYPE TYPE 2A TYPE TYPE NEEUQ QUEEN QUEEN QUEEN QUEEN QUEEN TV 3A TV 2B TV 2B ACCESS TV TV 2B TV 3B NEEUQ QUEEN QUEEN QUEEN QUEEN QUEEN MECH./ STAIR MAINT. STAIR NEEUQ QUEEN FD FD FD FD FD FD STOR ELEV. MW MW MW MW MW MW MW MW MW MW MW MW WM FD FD FD FD FD FD DF QUEEN NEEUQ 3BR 2BR 2BR 2BR 2BR 2BR 3BR QUEEN QUEEN QUEEN QUEEN QUEEN QUEEN NEEUQ TV TV TV TV TV TV VT QUEEN QUEEN QUEEN QUEEN QUEEN TYPE TYPE TYPE TYPE TYPE TYPE TYPE QUEEN NEEUQ 3B 2B 2B 2B 2A 2B 3B FD FD FD FD FD FD DF third floor plan 1"=20'-0" COLLEGE CREEK LOFTS & TOWNHOMES 09.10.20 ames, iowa building A - third floor plan - 05 © 2019 MVAH Development LLC
2 BR / 2 BATH TYPE 2A ACCESSIBLE UNIT DWELLING NET SF: 869 sf SQUARE FOOTAGES OF UNITS VARY PER EXTERIOR WALL CONDITIONS AND MW ADJACENCIES TO OTHER SPACE TYPES, REFER TO BUILDING FLOOR PLANS. REF ALL UNITS WILL BE PROVIDED WITH THE FOLLOWING AT A MINIMUM: BATH KITCHEN 1. HIGH SPEED INTERNET ACCESS SHALL BE PROVIDED. DATA WIRING PROVIDED SHALL MASTER BE CAPABLE OF SUPPORTING BROADBAND OF A MINIMUM 25 MBPS DOWNLOAD BATH SPEED. DW 2. BEDROOM CLOSETS SHALL BE 2' X 5' MINIMUM. 1 LINEN CLOSET AND 1 COAT CLOSET SHALL ALSO BE PROVIDED THAT ARE EACH 2' X 3' MINIMUM. FD LAUNDRY 3. REMOTE SECURITY AND INTERCOM SYSTEM SHALL BE PROVIDED. 4. VERTICAL GRAB BARS IN THE BATHTUBS/SHOWERS SHALL BE PROVIDED. DINING 5. LEVER DOOR HARDWARE SHALL BE PROVIDED THROUGH OUT UNITS. 6. WATER CONSERVING MEASURES SHALL BE PROVIDED, INCLUDING HIGH-EFFICIENCY WATERSENSE TOILETS THAT USE 1.28 GALLONS PER FLUSH OR LESS, FAUCET AERATORS THAT USE 1.5 GALLONS PER MINUTE OR LESS IN KITCHENS AND 1.0 GALLONS PER MINUTE IN BATHROOMS, SHOWERHEADS THAT USE 1.5 GALLONS PER MINUTE OR LESS. 7. IN-UNIT WATER HEATERS SHALL BE PROVIDED THAT HAVE A MINIMUM ENERGY QUEEN MASTER FACTOR OF .93 FOR TANK-TYPE ELECTRIC WATER HEATERS. BEDROOM BEDROOM 1 TV 8. ALL UNITS SHALL HAVE HEAT AND AIR CONDITIONING WITH EQUIPMENT THAT IS AT QUEEN LIVING ROOM LEAST 13 SEER (14.5 SEE AND 9.25 HSPF FOR ELECTRIC HEAT PUMPS) AND USE R-410a REFRIGERANT THAT IS CHARGED ACCORDING TO MANUFACTURER'S SPECIFICATIONS. 9. HOME ENERGY RATING SYSTEM INDEX OF 62 OR LESS. FD 10. ALL INTERIOR PAINTS AND PRIMERS COMPLY WITH GREEN SEAL STANDARDS FOR LOW VOC LIMITS. 11. ALL ADHESIVES COMPLY WITH RULE 1168 OF THE SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT. 12. ALL CAULKS AND SEALANTS COMPLY WITH REGULATION 8, RULE 51 OF THE BAY AREA AIR QUALITY MANAGEMENT DISTRICT. 13. ALL UNITS SHALL BE PROVIDED WITH IN-UNIT WASHER AND DRYERS unit plan 3/16"=1'-0" COLLEGE CREEK LOFTS & TOWNHOMES 09.10.20 ames, iowa 2 bedroom type 2A accessible - unit plan - 06 © 2019 MVAH Development LLC
2 BR / 2 BATH TYPE 2A UNIT DWELLING NET SF: 869 sf SQUARE FOOTAGES OF UNITS VARY PER EXTERIOR WALL CONDITIONS AND MW ADJACENCIES TO OTHER SPACE TYPES, REFER TO BUILDING FLOOR PLANS. REF ALL UNITS WILL BE PROVIDED WITH THE FOLLOWING AT A MINIMUM: BATH KITCHEN 1. HIGH SPEED INTERNET ACCESS SHALL BE PROVIDED. DATA WIRING PROVIDED SHALL MASTER BE CAPABLE OF SUPPORTING BROADBAND OF A MINIMUM 25 MBPS DOWNLOAD BATH SPEED. DW 2. BEDROOM CLOSETS SHALL BE 2' X 5' MINIMUM. 1 LINEN CLOSET AND 1 COAT CLOSET FD SHALL ALSO BE PROVIDED THAT ARE EACH 2' X 3' MINIMUM. LAUNDRY 3. REMOTE SECURITY AND INTERCOM SYSTEM SHALL BE PROVIDED. 4. VERTICAL GRAB BARS IN THE BATHTUBS/SHOWERS SHALL BE PROVIDED. DINING 5. LEVER DOOR HARDWARE SHALL BE PROVIDED THROUGH OUT UNITS. 6. WATER CONSERVING MEASURES SHALL BE PROVIDED, INCLUDING HIGH-EFFICIENCY WATERSENSE TOILETS THAT USE 1.28 GALLONS PER FLUSH OR LESS, FAUCET AERATORS THAT USE 1.5 GALLONS PER MINUTE OR LESS IN KITCHENS AND 1.0 GALLONS PER MINUTE IN BATHROOMS, SHOWERHEADS THAT USE 1.5 GALLONS PER MINUTE OR LESS. 7. IN-UNIT WATER HEATERS SHALL BE PROVIDED THAT HAVE A MINIMUM ENERGY QUEEN MASTER FACTOR OF .93 FOR TANK-TYPE ELECTRIC WATER HEATERS. BEDROOM BEDROOM 1 TV 8. ALL UNITS SHALL HAVE HEAT AND AIR CONDITIONING WITH EQUIPMENT THAT IS AT QUEEN LIVING ROOM LEAST 13 SEER (14.5 SEE AND 9.25 HSPF FOR ELECTRIC HEAT PUMPS) AND USE R-410a REFRIGERANT THAT IS CHARGED ACCORDING TO MANUFACTURER'S SPECIFICATIONS. 9. HOME ENERGY RATING SYSTEM INDEX OF 62 OR LESS. FD 10. ALL INTERIOR PAINTS AND PRIMERS COMPLY WITH GREEN SEAL STANDARDS FOR LOW VOC LIMITS. 11. ALL ADHESIVES COMPLY WITH RULE 1168 OF THE SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT. 12. ALL CAULKS AND SEALANTS COMPLY WITH REGULATION 8, RULE 51 OF THE BAY AREA AIR QUALITY MANAGEMENT DISTRICT. 13. ALL UNITS SHALL BE PROVIDED WITH IN-UNIT WASHER AND DRYERS unit plan 3/16"=1'-0" COLLEGE CREEK LOFTS & TOWNHOMES 09.10.20 ames, iowa 2 bedroom type 2A - unit plan - 07 © 2019 MVAH Development LLC
2 BR / 2 BATH TYPE 2B & 2C UNIT DWELLING NET SF: 869 sf SQUARE FOOTAGES OF UNITS VARY PER EXTERIOR WALL CONDITIONS AND MW ADJACENCIES TO OTHER SPACE TYPES, REFER TO BUILDING FLOOR PLANS. REF ALL UNITS WILL BE PROVIDED WITH THE FOLLOWING AT A MINIMUM: BATH KITCHEN 1. HIGH SPEED INTERNET ACCESS SHALL BE PROVIDED. DATA WIRING PROVIDED SHALL MASTER BE CAPABLE OF SUPPORTING BROADBAND OF A MINIMUM 25 MBPS DOWNLOAD BATH SPEED. DW 2. BEDROOM CLOSETS SHALL BE 2' X 5' MINIMUM. 1 LINEN CLOSET AND 1 COAT CLOSET FD SHALL ALSO BE PROVIDED THAT ARE EACH 2' X 3' MINIMUM. LAUNDRY 3. REMOTE SECURITY AND INTERCOM SYSTEM SHALL BE PROVIDED. 4. VERTICAL GRAB BARS IN THE BATHTUBS/SHOWERS SHALL BE PROVIDED. DINING 5. LEVER DOOR HARDWARE SHALL BE PROVIDED THROUGH OUT UNITS. 6. WATER CONSERVING MEASURES SHALL BE PROVIDED, INCLUDING HIGH-EFFICIENCY WATERSENSE TOILETS THAT USE 1.28 GALLONS PER FLUSH OR LESS, FAUCET AERATORS THAT USE 1.5 GALLONS PER MINUTE OR LESS IN KITCHENS AND 1.0 GALLONS PER MINUTE IN BATHROOMS, SHOWERHEADS THAT USE 1.5 GALLONS PER MINUTE OR LESS. 7. IN-UNIT WATER HEATERS SHALL BE PROVIDED THAT HAVE A MINIMUM ENERGY QUEEN MASTER FACTOR OF .93 FOR TANK-TYPE ELECTRIC WATER HEATERS. BEDROOM BEDROOM 1 TV 8. ALL UNITS SHALL HAVE HEAT AND AIR CONDITIONING WITH EQUIPMENT THAT IS AT QUEEN LIVING ROOM LEAST 13 SEER (14.5 SEE AND 9.25 HSPF FOR ELECTRIC HEAT PUMPS) AND USE R-410a REFRIGERANT THAT IS CHARGED ACCORDING TO MANUFACTURER'S SPECIFICATIONS. 9. HOME ENERGY RATING SYSTEM INDEX OF 62 OR LESS. FD 10. ALL INTERIOR PAINTS AND PRIMERS COMPLY WITH GREEN SEAL STANDARDS FOR LOW VOC LIMITS. 11. ALL ADHESIVES COMPLY WITH RULE 1168 OF THE SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT. 12. ALL CAULKS AND SEALANTS COMPLY WITH REGULATION 8, RULE 51 OF THE BAY AREA AIR QUALITY MANAGEMENT DISTRICT. 13. ALL UNITS SHALL BE PROVIDED WITH IN-UNIT WASHER AND DRYERS unit plan 3/16"=1'-0" COLLEGE CREEK LOFTS & TOWNHOMES 09.10.20 ames, iowa 2 bedroom type 2B / 2C - unit plan - 08 © 2019 MVAH Development LLC
3 BR / 2 BATH TYPE 3A ACCESSIBLE UNIT DWELLING NET SF: 1081 sf SQUARE FOOTAGES OF UNITS VARY PER EXTERIOR WALL CONDITIONS AND MW ADJACENCIES TO OTHER SPACE TYPES, REFER TO BUILDING FLOOR PLANS. REF ALL UNITS WILL BE PROVIDED WITH THE FOLLOWING AT A MINIMUM: BATH STORAGE KITCHEN MASTER 1. HIGH SPEED INTERNET ACCESS SHALL BE PROVIDED. DATA WIRING PROVIDED SHALL BATH BE CAPABLE OF SUPPORTING BROADBAND OF A MINIMUM 25 MBPS DOWNLOAD SPEED. DW 2. BEDROOM CLOSETS SHALL BE 2' X 5' MINIMUM. 1 LINEN CLOSET AND 1 COAT CLOSET SHALL ALSO BE PROVIDED THAT ARE EACH 2' X 3' MINIMUM. FD 3. REMOTE SECURITY AND INTERCOM SYSTEM SHALL BE PROVIDED. COAT LAUNDRY LINEN 4. VERTICAL GRAB BARS IN THE BATHTUBS/SHOWERS SHALL BE PROVIDED. DINING 5. LEVER DOOR HARDWARE SHALL BE PROVIDED THROUGH OUT UNITS. BEDROOM 2 QUEEN 6. WATER CONSERVING MEASURES SHALL BE PROVIDED, INCLUDING HIGH-EFFICIENCY WATERSENSE TOILETS THAT USE 1.28 GALLONS PER FLUSH OR LESS, FAUCET AERATORS THAT USE 1.5 GALLONS PER MINUTE OR LESS IN KITCHENS AND 1.0 GALLONS PER MINUTE IN BATHROOMS, SHOWERHEADS THAT USE 1.5 GALLONS PER MINUTE OR LESS. 7. IN-UNIT WATER HEATERS SHALL BE PROVIDED THAT HAVE A MINIMUM ENERGY QUEEN FACTOR OF .93 FOR TANK-TYPE ELECTRIC WATER HEATERS. BEDROOM 1 TV MASTER 8. ALL UNITS SHALL HAVE HEAT AND AIR CONDITIONING WITH EQUIPMENT THAT IS AT LIVING ROOM BEDROOM QUEEN LEAST 13 SEER (14.5 SEE AND 9.25 HSPF FOR ELECTRIC HEAT PUMPS) AND USE R-410a REFRIGERANT THAT IS CHARGED ACCORDING TO MANUFACTURER'S SPECIFICATIONS. 9. HOME ENERGY RATING SYSTEM INDEX OF 62 OR LESS. FD 10. ALL INTERIOR PAINTS AND PRIMERS COMPLY WITH GREEN SEAL STANDARDS FOR LOW VOC LIMITS. 11. ALL ADHESIVES COMPLY WITH RULE 1168 OF THE SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT. 12. ALL CAULKS AND SEALANTS COMPLY WITH REGULATION 8, RULE 51 OF THE BAY AREA AIR QUALITY MANAGEMENT DISTRICT. 13. ALL UNITS SHALL BE PROVIDED WITH IN-UNIT WASHER AND DRYERS unit plan 3/16"=1'-0" COLLEGE CREEK LOFTS & TOWNHOMES 09.10.20 ames, iowa 3 bedroom type 3A accessible - unit plan - 09 © 2019 MVAH Development LLC
3 BR / 2 BATH TYPE 3A UNIT DWELLING NET SF: 1081 sf SQUARE FOOTAGES OF UNITS VARY PER EXTERIOR WALL CONDITIONS AND MW ADJACENCIES TO OTHER SPACE TYPES, REFER TO BUILDING FLOOR PLANS. REF ALL UNITS WILL BE PROVIDED WITH THE FOLLOWING AT A MINIMUM: BATH STORAGE KITCHEN MASTER 1. HIGH SPEED INTERNET ACCESS SHALL BE PROVIDED. DATA WIRING PROVIDED SHALL BATH BE CAPABLE OF SUPPORTING BROADBAND OF A MINIMUM 25 MBPS DOWNLOAD SPEED. DW 2. BEDROOM CLOSETS SHALL BE 2' X 5' MINIMUM. 1 LINEN CLOSET AND 1 COAT CLOSET SHALL ALSO BE PROVIDED THAT ARE EACH 2' X 3' MINIMUM. FD 3. REMOTE SECURITY AND INTERCOM SYSTEM SHALL BE PROVIDED. COAT LAUNDRY LINEN 4. VERTICAL GRAB BARS IN THE BATHTUBS/SHOWERS SHALL BE PROVIDED. DINING 5. LEVER DOOR HARDWARE SHALL BE PROVIDED THROUGH OUT UNITS. BEDROOM 2 QUEEN 6. WATER CONSERVING MEASURES SHALL BE PROVIDED, INCLUDING HIGH-EFFICIENCY WATERSENSE TOILETS THAT USE 1.28 GALLONS PER FLUSH OR LESS, FAUCET AERATORS THAT USE 1.5 GALLONS PER MINUTE OR LESS IN KITCHENS AND 1.0 GALLONS PER MINUTE IN BATHROOMS, SHOWERHEADS THAT USE 1.5 GALLONS PER MINUTE OR LESS. 7. IN-UNIT WATER HEATERS SHALL BE PROVIDED THAT HAVE A MINIMUM ENERGY QUEEN FACTOR OF .93 FOR TANK-TYPE ELECTRIC WATER HEATERS. BEDROOM 1 TV MASTER 8. ALL UNITS SHALL HAVE HEAT AND AIR CONDITIONING WITH EQUIPMENT THAT IS AT LIVING ROOM BEDROOM QUEEN LEAST 13 SEER (14.5 SEE AND 9.25 HSPF FOR ELECTRIC HEAT PUMPS) AND USE R-410a REFRIGERANT THAT IS CHARGED ACCORDING TO MANUFACTURER'S SPECIFICATIONS. 9. HOME ENERGY RATING SYSTEM INDEX OF 62 OR LESS. FD 10. ALL INTERIOR PAINTS AND PRIMERS COMPLY WITH GREEN SEAL STANDARDS FOR LOW VOC LIMITS. 11. ALL ADHESIVES COMPLY WITH RULE 1168 OF THE SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT. 12. ALL CAULKS AND SEALANTS COMPLY WITH REGULATION 8, RULE 51 OF THE BAY AREA AIR QUALITY MANAGEMENT DISTRICT. 13. ALL UNITS SHALL BE PROVIDED WITH IN-UNIT WASHER AND DRYERS unit plan 3/16"=1'-0" COLLEGE CREEK LOFTS & TOWNHOMES 09.10.20 ames, iowa 3 bedroom type 3A - unit plan - 10 © 2019 MVAH Development LLC
3 BR / 2 BATH TYPE 3B / 3C UNIT DWELLING NET SF: 1081 sf SQUARE FOOTAGES OF UNITS VARY PER EXTERIOR WALL CONDITIONS AND MW ADJACENCIES TO OTHER SPACE TYPES, REFER TO BUILDING FLOOR PLANS. REF ALL UNITS WILL BE PROVIDED WITH THE FOLLOWING AT A MINIMUM: BATH STORAGE KITCHEN MASTER 1. HIGH SPEED INTERNET ACCESS SHALL BE PROVIDED. DATA WIRING PROVIDED SHALL BATH BE CAPABLE OF SUPPORTING BROADBAND OF A MINIMUM 25 MBPS DOWNLOAD SPEED. DW 2. BEDROOM CLOSETS SHALL BE 2' X 5' MINIMUM. 1 LINEN CLOSET AND 1 COAT CLOSET SHALL ALSO BE PROVIDED THAT ARE EACH 2' X 3' MINIMUM. FD 3. REMOTE SECURITY AND INTERCOM SYSTEM SHALL BE PROVIDED. COAT LAUNDRY LINEN 4. VERTICAL GRAB BARS IN THE BATHTUBS/SHOWERS SHALL BE PROVIDED. DINING 5. LEVER DOOR HARDWARE SHALL BE PROVIDED THROUGH OUT UNITS. BEDROOM 2 QUEEN 6. WATER CONSERVING MEASURES SHALL BE PROVIDED, INCLUDING HIGH-EFFICIENCY WATERSENSE TOILETS THAT USE 1.28 GALLONS PER FLUSH OR LESS, FAUCET AERATORS THAT USE 1.5 GALLONS PER MINUTE OR LESS IN KITCHENS AND 1.0 GALLONS PER MINUTE IN BATHROOMS, SHOWERHEADS THAT USE 1.5 GALLONS PER MINUTE OR LESS. 7. IN-UNIT WATER HEATERS SHALL BE PROVIDED THAT HAVE A MINIMUM ENERGY QUEEN FACTOR OF .93 FOR TANK-TYPE ELECTRIC WATER HEATERS. BEDROOM 1 TV MASTER 8. ALL UNITS SHALL HAVE HEAT AND AIR CONDITIONING WITH EQUIPMENT THAT IS AT LIVING ROOM BEDROOM QUEEN LEAST 13 SEER (14.5 SEE AND 9.25 HSPF FOR ELECTRIC HEAT PUMPS) AND USE R-410a REFRIGERANT THAT IS CHARGED ACCORDING TO MANUFACTURER'S SPECIFICATIONS. 9. HOME ENERGY RATING SYSTEM INDEX OF 62 OR LESS. FD 10. ALL INTERIOR PAINTS AND PRIMERS COMPLY WITH GREEN SEAL STANDARDS FOR LOW VOC LIMITS. 11. ALL ADHESIVES COMPLY WITH RULE 1168 OF THE SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT. 12. ALL CAULKS AND SEALANTS COMPLY WITH REGULATION 8, RULE 51 OF THE BAY AREA AIR QUALITY MANAGEMENT DISTRICT. 13. ALL UNITS SHALL BE PROVIDED WITH IN-UNIT WASHER AND DRYERS unit plan 3/16"=1'-0" COLLEGE CREEK LOFTS & TOWNHOMES 09.10.20 ames, iowa 3 bedroom type 3B / 3C - unit plan - 11 © 2019 MVAH Development LLC
EXTERIOR FINISH LEGEND FACE BRICK VENEER (FB-1) FIBER CEMENT SIDING, LAP-STYLE (FC-1). FIBER CEMENT SIDING, SHAKE-STYLE (FC-2). ROOFING, ARCHITECTURAL FIBERGLASS SHINGLES (AFS-1). ANTI-FUNGAL AND MIN. 30-YEAR WARRANTY SHEET METAL FLASHING AND TRIM. ALL PRE-FINISHED METAL GUTTER, DOWNSPOUTS, FASCIAS, ETC. TO BE BY DIMENSIONAL METALS INC. COLLEGE CREEK LOFTS & TOWNHOMES 09.10.20 ames, iowa building A - building elevations - 12 © 2019 MVAH Development LLC
EXTERIOR FINISH LEGEND FACE BRICK VENEER (FB-1) FIBER CEMENT SIDING, LAP-STYLE (FC-1). FIBER CEMENT SIDING, SHAKE-STYLE (FC-2). ROOFING, ARCHITECTURAL FIBERGLASS SHINGLES (AFS-1). ANTI-FUNGAL AND MIN. 30-YEAR WARRANTY SHEET METAL FLASHING AND TRIM. ALL PRE-FINISHED METAL GUTTER, DOWNSPOUTS, FASCIAS, ETC. TO BE BY DIMENSIONAL METALS INC. COLLEGE CREEK LOFTS & TOWNHOMES 09.10.20 ames, iowa building A - building elevations - 13 © 2019 MVAH Development LLC
BUILDING WILL BE PROVIDED WITH THE FOLLOWING AT A MINIMUM: 1. A MINIMUM OF ONE 5' ADA COMPLIANT ROLL-IN SHOWER PER 20 UNITS SHALL BE PROVIDED. UNITS SHALL BE DISPERSED THROUGHOUT THE BUILDING. 2. WATER CONSERVING MEASURES SHALL BE PROVIDED, INCLUDING HIGH-EFFICIENCY WATERSENSE TOILETS THAT USE 1.28 GALLONS PER FLUSH OR LESS, FAUCET AERATORS THAT USE 1.5 GALLONS PER MINUTE OR LESS IN KITCHENS AND 1.0 GALLONS PER MINUTE IN BATHROOMS, SHOWERHEADS THAT USE 1.5 GALLONS PER MINUTE OR LESS. 3. A PASSIVE RADON SYSTEM SHALL BE PROVIDED. 4. A MINIMUM OF TWO PERCENT (2%) OF ALL UNITS SUPPLIED SHALL BE ADAPTED FOR HEARING AND second floor plan VISION IMPAIRMENTS AS UNITS WITH ACCESSIBLE COMMUNICATIONS FEATURES. 1/16" = 1'-0" 5. BUILDING DESIGN WILL COMPLY WITH IOWA FINANCE AGENCY 2021 QAP APPENDIX J BUILDING STANDARDS. 3BR 3BR 3BR 3BR 3BR 3BR TYPE TYPE TYPE TYPE TYPE TYPE 3A 3B 3B 3B 3B 3B TOWNHOME TOWNHOME TOWNHOME TOWNHOME TOWNHOME TOWNHOME first floor plan 1/16" = 1'-0" COLLEGE CREEK LOFTS & TOWNHOMES 09.10.20 ames, iowa building B - floor plans - 14 © 2019 MVAH Development LLC
BUILDING WILL BE PROVIDED WITH THE FOLLOWING AT A MINIMUM: 1. A MINIMUM OF ONE 5' ADA COMPLIANT ROLL-IN SHOWER PER 20 UNITS SHALL BE PROVIDED. UNITS SHALL BE DISPERSED THROUGHOUT THE BUILDING. 2. WATER CONSERVING MEASURES SHALL BE PROVIDED, INCLUDING HIGH-EFFICIENCY WATERSENSE TOILETS THAT USE 1.28 GALLONS PER FLUSH OR LESS, FAUCET AERATORS THAT USE 1.5 GALLONS PER MINUTE OR LESS IN KITCHENS AND 1.0 GALLONS PER MINUTE IN BATHROOMS, SHOWERHEADS THAT USE 1.5 GALLONS PER MINUTE OR LESS. 3. A PASSIVE RADON SYSTEM SHALL BE PROVIDED. 4. A MINIMUM OF TWO PERCENT (2%) OF ALL UNITS SUPPLIED SHALL BE ADAPTED FOR HEARING AND second floor plan VISION IMPAIRMENTS AS UNITS WITH ACCESSIBLE COMMUNICATIONS FEATURES. 1/16" = 1'-0" 5. BUILDING DESIGN WILL COMPLY WITH IOWA FINANCE AGENCY 2021 QAP APPENDIX J BUILDING STANDARDS. 3BR 3BR 3BR 3BR 3BR 3BR 3BR 3BR TYPE TYPE TYPE TYPE TYPE TYPE TYPE TYPE 3B 3B 3B 3B 3B 3B 3B 3A TOWNHOME TOWNHOME TOWNHOME TOWNHOME TOWNHOME TOWNHOME TOWNHOME TOWNHOME first floor plan 1/16" = 1'-0" COLLEGE CREEK LOFTS & TOWNHOMES 09.10.20 ames, iowa building C - floor plans - 15 © 2019 MVAH Development LLC
3 BR / 2 BATH TYPE 3A TOWNHOME UNIT WALL MIRROR MEDICINE CABINET DWELLING NET SF: 1222 sf WALL CABINETS WITHIN ACCESSIBLE REACH MASTER REF. BATH RANGES SQUARE FOOTAGES OF UNITS VARY PER EXTERIOR WALL CONDITIONS AND 9'-8"x5'-10" 55 SF ADJACENCIES TO OTHER SPACE TYPES, REFER TO BUILDING FLOOR PLANS. FULLY VISITABLE KITCHEN VINYL MASTER ALL UNITS WILL BE PROVIDED WITH THE FOLLOWING AT A MINIMUM: QUEEN VENTED RANGE HOOD KITCHEN BEDROOM 10'-8"x13'-11" 10'-7"x13'-8" RANGE 148 SF 125 SF 1. HIGH SPEED INTERNET ACCESS SHALL BE PROVIDED. DATA WIRING PROVIDED SHALL SHELVES VINYL CARPET PANTRY BE CAPABLE OF SUPPORTING BROADBAND OF A MINIMUM 25 MBPS DOWNLOAD REMOVABLE BASE 8 SF CABINET BELOW KITCHEN VINYL WALK-IN SPEED. SINK FOR ACCESSIBLE CLOSET ACCESS D.W. 6'-0" X 6'-5" 2. BEDROOM CLOSETS SHALL BE 2' X 5' MINIMUM. 1 LINEN CLOSET AND 1 COAT CLOSET 39 SF GARBAGE DISPOSAL CARPET SHALL ALSO BE PROVIDED THAT ARE EACH 2' X 3' MINIMUM. BREAKFAST BAR LAUNDRY 16 SF 3. REMOTE SECURITY AND INTERCOM SYSTEM SHALL BE PROVIDED. VINYL ACCESSIBLE ADA COMPLIANT 4. VERTICAL GRAB BARS IN THE BATHTUBS/SHOWERS SHALL BE PROVIDED. BATHROOM ROLL-IN SHOWER 8'-5" X 7'-11" COAT 67 SF 5. LEVER DOOR HARDWARE SHALL BE PROVIDED THROUGH OUT UNITS. CLOSET MECH CERAMIC TILE DINING 5 SF 9 SF 6. WATER CONSERVING MEASURES SHALL BE PROVIDED, INCLUDING HIGH-EFFICIENCY 10'-7"x13'-8" 122 SF WATERSENSE TOILETS THAT USE 1.28 GALLONS PER FLUSH OR LESS, FAUCET VINYL FULLY VISITABLE HALL BATHROOM AERATORS THAT USE 1.5 GALLONS PER MINUTE OR LESS IN KITCHENS AND 1.0 4'-0" X 15'-5" 62 SF WALL MIRROR GALLONS PER MINUTE IN BATHROOMS, SHOWERHEADS THAT USE 1.5 GALLONS PER VINYL MEDICINE CABINET MINUTE OR LESS. 7. IN-UNIT WATER HEATERS SHALL BE PROVIDED THAT HAVE A MINIMUM ENERGY FULL FACTOR OF .93 FOR TANK-TYPE ELECTRIC WATER HEATERS. BEDROOM 2 8. ALL UNITS SHALL HAVE HEAT AND AIR CONDITIONING WITH EQUIPMENT THAT IS AT 9'-8"x12'-3" LINEN 118 SF LEAST 13 SEER (14.5 SEE AND 9.25 HSPF FOR ELECTRIC HEAT PUMPS) AND USE 8 SF CARPET R-410a REFRIGERANT THAT IS CHARGED ACCORDING TO MANUFACTURER'S SHELVES SPECIFICATIONS. 9. HOME ENERGY RATING SYSTEM INDEX OF 62 OR LESS. FULL LIVING ROOM BEDROOM 3 10. ALL INTERIOR PAINTS AND PRIMERS COMPLY WITH GREEN SEAL STANDARDS FOR 12'-8"x13'-11" 9'-0"x12'-3" CLOSET CLOSET 176 SF 110 SF 12 SF 12 SF LOW VOC LIMITS. VINYL CARPET CARPET CARPET 11. ALL ADHESIVES COMPLY WITH RULE 1168 OF THE SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT. 12. ALL CAULKS AND SEALANTS COMPLY WITH REGULATION 8, RULE 51 OF THE BAY AREA AIR QUALITY MANAGEMENT DISTRICT. ROD & SHELF 13. ALL UNITS SHALL BE PROVIDED WITH IN-UNIT WASHER AND DRYERS unit plan 3/16"=1'-0" COLLEGE CREEK LOFTS & TOWNHOMES 09.10.20 ames, iowa 3 bedroom type 3A townhome - unit plan - 16 © 2019 MVAH Development LLC
3 BR / 2 BATH TYPE 3B & 3C TOWNHOME UNIT 1ST FLR NET SF: 621 sf REF. 2ND FLR NET SF: 577 sf WH SQUARE FOOTAGES OF UNITS VARY PER EXTERIOR WALL CONDITIONS AND ADJACENCIES TO OTHER SPACE TYPES, REFER TO BUILDING FLOOR PLANS. FULL VENTED RANGE HOOD RANGE LAUNDRY/UTILITY KITCHEN 6'-0"x9'-4" ALL UNITS WILL BE PROVIDED WITH THE FOLLOWING AT A MINIMUM: 11'-3"x11'-11" 56 SF QUEEN 134 SF VINYL GARBAGE DISPOSAL VINYL 1. HIGH SPEED INTERNET ACCESS SHALL BE PROVIDED. DATA WIRING PROVIDED SHALL SHELVES W D BE CAPABLE OF SUPPORTING BROADBAND OF A MINIMUM 25 MBPS DOWNLOAD DW BEDROOM SPEED. 9'-0"x10'-3" 92 SF 2. BEDROOM CLOSETS SHALL BE 2' X 5' MINIMUM. 1 LINEN CLOSET AND 1 COAT CLOSET BREAKFAST BAR BEDROOM CARPET WALL MIRROR 9'-0"x12'-0" CLOSET SHALL ALSO BE PROVIDED THAT ARE EACH 2' X 3' MINIMUM. MEDICINE 108 SF 2'-0" x 4'-11" CABINET CARPET 10 SF 3. REMOTE SECURITY AND INTERCOM SYSTEM SHALL BE PROVIDED. CLOSET CARPET HALF BATH FULLY 6'-0"x7'-4" VISITABLE 2'-0" x 4'-6" 4. VERTICAL GRAB BARS IN THE BATHTUBS/SHOWERS SHALL BE PROVIDED. DINING 44 SF BATHROOM 9 SF 10'-9"x11'-11" VINYL CARPET 5. LEVER DOOR HARDWARE SHALL BE PROVIDED THROUGH OUT UNITS. 128 SF ROD & SHELF VINYL 6. WATER CONSERVING MEASURES SHALL BE PROVIDED, INCLUDING HIGH-EFFICIENCY HALL WATERSENSE TOILETS THAT USE 1.28 GALLONS PER FLUSH OR LESS, FAUCET 5'-5"x9'-8" MEDICINE BATHROOM 55 SF AERATORS THAT USE 1.5 GALLONS PER MINUTE OR LESS IN KITCHENS AND 1.0 CABINET 5'-10"x8'-7" CARPET UNDER-STAIR 50 SF STORAGE WALL MIRROR GALLONS PER MINUTE IN BATHROOMS, SHOWERHEADS THAT USE 1.5 GALLONS PER VINYL 3'-8"x6'-0" 22 SF MINUTE OR LESS. VINYL 7. IN-UNIT WATER HEATERS SHALL BE PROVIDED THAT HAVE A MINIMUM ENERGY LINEN 1'-4" x 3'-8" FACTOR OF .93 FOR TANK-TYPE ELECTRIC WATER HEATERS. 5 SF CARPET 8. ALL UNITS SHALL HAVE HEAT AND AIR CONDITIONING WITH EQUIPMENT THAT IS AT TV LEAST 13 SEER (14.5 SEE AND 9.25 HSPF FOR ELECTRIC HEAT PUMPS) AND USE LIVING ROOM R-410a REFRIGERANT THAT IS CHARGED ACCORDING TO MANUFACTURER'S 11'-11"x14'-3" 170 SF SPECIFICATIONS. VINYL CLOSET 9. HOME ENERGY RATING SYSTEM INDEX OF 62 OR LESS. QUEEN 3'-8" x 8'-4" 30 SF MASTER CARPET 10. ALL INTERIOR PAINTS AND PRIMERS COMPLY WITH GREEN SEAL STANDARDS FOR BEDROOM 10'-4"x14'-3" LOW VOC LIMITS. ENTRY 136 SF 3'-8"x5'-0" CARPET 11. ALL ADHESIVES COMPLY WITH RULE 1168 OF THE SOUTH COAST AIR QUALITY 18 SF VINYL MANAGEMENT DISTRICT. 12. ALL CAULKS AND SEALANTS COMPLY WITH REGULATION 8, RULE 51 OF THE BAY AREA AIR QUALITY MANAGEMENT DISTRICT. AUDIBLE AND VISUAL SIGNALS INCLUDING A STROBE/HORN TYPE 13. ALL UNITS SHALL BE PROVIDED WITH IN-UNIT WASHER AND DRYERS VISUAL SIGNALING DEVICE WIRED TO ALL SMOKE DETECTORS IN SIGHT AND HEARING IMPAIRED UNITS ONLY FIRST FLOOR SECOND FLOOR unit plan 3/16"=1'-0" COLLEGE CREEK LOFTS & TOWNHOMES 09.10.20 ames, iowa 3 bedroom type 3B / 3C townhome - unit plan - 17 © 2019 MVAH Development LLC
EXTERIOR FINISH LEGEND FACE BRICK VENEER (FB-1) FIBER CEMENT SIDING, LAP-STYLE (FC-1). FIBER CEMENT SIDING, SHAKE-STYLE (FC-2). ROOFING, ARCHITECTURAL FIBERGLASS SHINGLES (AFS-1). ANTI-FUNGAL AND MIN. 30-YEAR WARRANTY SHEET METAL FLASHING AND TRIM. ALL PRE-FINISHED METAL GUTTER, DOWNSPOUTS, FASCIAS, ETC. TO BE BY DIMENSIONAL METALS INC. COLLEGE CREEK LOFTS & TOWNHOMES 09.10.20 ames, iowa buildings B & C - building elevations - 18 © 2019 MVAH Development LLC
COLLEGE CREEK LOFTS & TOWNHOMES 09.10.20 ames, iowa representative project rendering - 19 © 2019 MVAH Development LLC
ATTACHMENT B—ENERGY CONSERVATION AND GREEN BUILDING FEATURES CITY OF AMES RFP Attachment B includes the following: • Summary of energy conservation and green building features.
Energy Conservation and Green Building Features MVAH is committed to energy conservation and environmental stewardship throughout our portfolio. Nearly all of our new developments, and every MVAH project in Iowa, achieve EnergyStar Certification and Home Energy Rating System (HERS) of 62 or less, making them among the most efficient new construction buildings in the country. This project will meet exceed or exceed those expectations, as well. MVAH achieves this by including energy efficient LED lighting exclusively, using Energy Star certified appliances and Heating, Cooling, and Domestic Hot Water Equipment. Every unit will have its own smart thermostat and residents will be trained to program home and away schedules as part of the move-in process. All three building will have enhanced buildings envelopes and be subject to blower door testing to detect air leakage and a rigorous commissioning process for the mechanical equipment. We will also use Watersense recognized conservation measures, including: a) High-efficiency toilets that use 1.28 gallons per flush or less, b) faucet aerators that use 1.5 gallons per minute or less in kitchens and 1.0 gallons per minute in bathrooms, and c) showerheads that use 1.5 gallons per minute or less. This project gives us the unique ability to connect to the regional geothermal system. We know that it will not only be important to right size the equipment in our buildings, but to also provide residents outreach, tools and training to truly achieve savings. We are committed to working with the community, our design team, and our residents to maximize the energy savings. In addition to energy conservation, MVAH pays special attention to make sure the air inside the buildings is safe and healthy. Especially in these unusual times, healthy indoor air and preventing cross contamination is critically important. In this region, we always provide depressurized units via an always on active ventilation system creating an environment where odors and contaminates will not infiltrate from unit to the next. To have clean healthy air you must start with safe building materials. We only use low Volatile Organic Chemical (VOC) interior paints and primers that comply with Green Seal Standards. All adhesives will comply with rule 1168 of the South Coast Air Quality Management District and all caulks and other sealants will comply with Regulation 8, Rule 51 of the Bay Area Air Quality Management District. Our commitment to the environment does not end at the walls of the building. We will also recycle everything that is recyclable during the construction process, use native planting to limit water usage, Plant shade tress to contribute to lower heating an cooling costs, and use only high efficiency daylight sensing LED site lighting that is properly shielded to reduce light pollution. 9100 Centre Pointe Dr. Suite 210 West Chester, OH 45069 (513)-964-1140
ATTACHMENT C—FINANCING PLAN CITY OF AMES RFP Attachment C includes the following: • Project proforma including proposed funding sources. • Estimated construction costs (accounting for federal Prevailing Wage requirements). • Incentives requested to support the project.
Sources and Uses College Creek Lofts and Townhomes City Ames Iowa Construction Permanent Per Unit Sources First Mortgage $ - $ 2,562,806 $ 51,256 Construction Loan $ 7,570,942 HOME $ 400,000 Tax Abatement $ - Tax Abatement $ - $ - LIHTC Equity $ 1,461,454 $ 7,307,269 $ 146,145 Neighborworks $ - GP Equity $ 100 $ 100 $ 2 Deferred Developer Fee $ - $ 127,198 $ 2,544 Total $ 9,032,496 $ 10,397,373 $ 207,947 Project Cost Subtotals Per Unit Acq Basis Rehab/Cons Basis Uses Property Acquisition Land Acquisition Cost $ - $ - $ - Building Cost $ - $ - $ - Transfer Taxes $ - $ - Payoff/Assumption of Existing Debt $ - $ - Prepayment Penalty $ - $ - Carrying Costs $ - Acquisition Total $ - $ - Construction/Rehab Costs $ 6,607,143 $ 132,143 $ 6,607,143 General Requirements $ 264,286 $ 5,286 $ 264,286 Builder's Overhead $ 132,143 $ 2,643 $ 132,143 Builder's Profit $ 264,286 $ 5,286 $ 264,286 Bonding Fee $ 66,071 $ 1,321 $ 66,071 Builder's Risk Insurance $ 66,071 $ 1,321 $ 66,071 Construction Subtotal $ 7,400,000 $ 148,000 Hard Cost Contingency $ 363,393 $ 363,393 $ 7,268 $ 72,679 Environmental Remediation $ 25,000 $ 500 $ 25,000 Geotech $ 25,000 $ 500 $ 25,000 Permits $ 25,000 $ 500 $ 25,000 State Surcharge $ - Security $ - Appraisal $ 15,000 $ 300 $ 15,000 Environmental - Phase I $ 10,000 $ 200 $ 10,000 Environmental - Phase II $ - $ - $ - Parkland Dedication Fee $ 1 $ 0 $ 1 Market Study $ 10,000 $ 200 $ 10,000 Survey $ 10,000 $ 200 $ 10,000 Traffic/Corridor Study $ - $ - Legal - Organization $ - Legal - Transaction $ 75,000 $ 1,500 $ 75,000 Legal - Syndication Legal - Misc $ - Accounting $ 27,500 $ 550 Title & Recording $ 33,000 $ 660 $ 33,000 Architecture & Engineering $ 296,000 $ 5,920 $ 296,000 Additional A&E $ 30,000 $ 600 Initial Lease Up $ - Soft Contingency $ - Furniture & Equipment $ 50,000 $ 1,000 $ 50,000 Construction period insurance $ 40,000 $ 800 $ 40,000
Construction period real estate taxes $ 20,500 $ 410 Development Costs Subtotal $ 692,001 $ - Operating Reserve $ 206,293 $ 4,126 Working Capital Reserve $ - Tax & Insurance Escrow $ 135,675 $ 2,714 IOD Reserve $ - Replacement Reserve $ 20,000 $ 400 Revenue Deficit Reserves $ - Reserves/Escrows $ 361,968 $ - LIHTC Allocation and Reservation Fee $ 84,000 $ 1,680 IAHTC Reservation Fee Syndicator Fee/Legal $ - Cost Certification $ 10,000 $ 200 $ 10,000 Constructon Plan & Cost Review $ 20,000 $ 400 $ 20,000 Historic Tax Consultant $ - $ - $ - Application & Issuance Fee $ 14,000 $ 280 First Mortgage Origination $ 25,628 $ 513 MIP $ - First Mort Debt Service Reserve $ - Custodian Fee First Mort Legal Fee $ 35,000 $ 700 Swap $ - Construction Loan Fee $ 49,211 $ 984 Construction Loan Inspection $ 20,000 $ 400 Construction - cost review $ 10,000 $ 200 Lender Legal $ 45,000 $ 900 Lender Conversion Fee $ - Issuer Fee - Series A $ - Issuer Counsel Fee - Series A $ - Bond Counsel Fee - Series A $ - Underwriting Fee - Series A $ - Underwriter's Counsel - Series A $ - Trustee and Counsel - Series A $ - Rating Agency - Series A $ - Printing $ - Negative Arbitrage $ - Underwriter Counsel - Series B $ - Underwriter Takedown - Series B $ - Bond Counsel - Series B $ - Series B LOC fee $ - $ - Series B Interest (Negative Arb) $ - $ - Series B Rating $ - Series B Legal $ - Construction Loan - Interest $ 280,000 $ 5,600 $ 254,819 Financing Subtotal $ 592,839 $ - Developer Fee $ 987,172 $ 987,172 $ 19,743 $ 987,172 Total $ 10,397,373 $ 10,397,373 $ 207,947 $ - $ 9,358,670
Unit Mix & Income College Creek Lofts and Townhomes Rental Income Beds Baths % of AMI Average SF # of Units Total SF Gross Rent Utility Net Rent Subsidy Monthly Income Annual Rental per Unit Allowance Income 2 BR 2 30% 900 4 8.00% 3,600 639 $ 111 528 No $ 2,112 25,344 2 BR 2 40% 900 8 16.00% 7,200 852 $ 111 741 No $ 5,928 71,136 2 BR 2 60% 900 10 20.00% 9,000 875 $ 111 $ 764 No $ 7,640 $ 91,680 2 BR 2 Market 900 3 6.00% 2,700 875 $ - $ 875 No $ 2,625 $ 31,500 3 BR 2 30% 1250 4 8.00% 5,000 738 $ 139 $ 599 No $ 2,396 $ 28,752 3 BR 2 40% 1250 7 14.00% 8,750 984 $ 139 $ 845 No $ 5,915 $ 70,980 3 BR 2 60% 1250 12 24.00% 15,000 1,000 $ 139 $ 861 No $ 10,332 $ 123,984 3 BR 2 Market 1250 2 4.00% 2,500 1,000 $ - $ 1,000 No $ 2,000 $ 24,000 Total 50 53,750 $ 38,948 $ 467,376 Utility Allowances Heating - Electric Cooking Other Electric A/C Water Heating Electric (gas) Efficiency One Bedroom $ 18 $ 8 $ 26 $ 4 $ 7 Two Bedroom $ 34 $ 10 $ 34 $ 7 $ 26 Three Bedroom $ 43 $ 11 $ 42 $ 10 $ 33 Four Bedroom Other Income Total Income Income Limits General Other Income $ 6,000 IFA Vending 2020 30% 40% 50% 60% Parking Efficiency $ 497 $ 663 $ 828 $ 994 Late Fees One Bedroom $ 532 $ 710 $ 887 $ 1,065 Total $ 6,000 Two Bedroom $ 639 $ 852 $ 1,065 $ 1,278 Three Bedroom $ 738 $ 984 $ 1,230 $ 1,476 Total Gross Potential Income $ 473,376 Four Bedroom Less Residential Vacancy 7% $ (32,716) Less Commercial Vacancy 50% $ - Less Other Income Vacancy 7% $ (420) Total Effective Gross Income $ 440,240 Operating Expenses $ 252,043 Replacement Reserve $ 15,000
Operating Expenses College Creek Lofts and Townhomes Stabilized Year per unit Admin Expenses Advertising and Marketing 1,000 $ 20 Other Renting Expenses $ - Office Expenses 5,000 $ 100 Office or Model Apartment Rent $ - Management Fee 6% 28,043 $ 561 Administrative Rent Free Unit - $ - Legal & Accounting Expense 10,000 $ 200 Audit Expense 5,000 $ 100 Miscellaneous Admin Expense $ - Total Admin Expenses 49,043 $ 981 Utilities Utility Mgmt $ - Electricity 2,000 $ 40 Water 2,000 $ 40 Gas 2,000 $ 40 Sewer 4,000 $ 80 Trash $ - Total Utilities Expenses 10,000 $ 200 Operating and Maintenance Supplies $ - Contracts 3,000 $ 60 Elevators Extermination 3,000 $ 60 Garbage and Trash Removal 3,000 $ 60 Security Payroll/Contract $ - Security Other $ - Heating/Cooling Repairs/Maint. 3,000 $ 60 Landscaping / Snow Removal $ - Turnover 2,500 $ 50 Miscellaneous O & M $ - Total O&M Expenses 14,500 $ 290 Payroll Admin / Mgr Payroll 50,000$ 1,000 Maintenance Payroll 50,000$ 1,000 Front Desk - $ - Benefits & Payroll Taxes (% of Payroll) 25% 25,000$ 500 Workers Comp $ - Total Payroll 125,000 $ 2,500 Taxes and Insurance Real Estate Taxes 41,000 $ 820 Property and Liability Insurance 12,500 $ 250
Fidelity Bond Insurance $ - Lease $ - Total Taxes & Insurance 53,500 $ 1,070 Total Cost of Operations 252,043 $ 5,041 Replacement Reserve Deposits $ 300 $ 15,000 $ 300 Total Cost of Operations Including Rep Res 267,043 $ 5,341
15-Year Cashflow College Creek Lofts and Townhomes Assumptions Residential Escalation 2% Commercial Escalation 2% Other Income Escalation 0% Expense Escalation 3% Property Tax Escalation 4% Replacement Reserve Escalation 3% Residential Vacancy 7% Commercial Vacancy 50% Other Income Vacancy 7% Income Year 1 Year 2 Year 3 Year 4 Year 5 Year 6 Year 7 Year 8 Year 9 Year 10 Year 11 Year 12 Year 13 Year 14 Year 15 Residential GPR $ 467,376 $ 476,724 $ 486,258 $ 495,983 $ 505,903 $ 516,021 $ 526,341 $ 536,868 $ 547,605 $ 558,558 $ 569,729 $ 581,123 $ 592,746 $ 604,601 $ 616,693 Commercial GPR $ - $ - $ - $ - $ - $ - $ - $ - $ - $ - $ - $ - $ - $ - $ - Other Income GPR $ 6,000 $ 6,000 $ 6,000 $ 6,000 $ 6,000 $ 6,000 $ 6,000 $ 6,000 $ 6,000 $ 6,000 $ 6,000 $ 6,000 $ 6,000 $ 6,000 $ 6,000 (Res Vacancy) $ (32,716) $ (33,371) $ (34,038) $ (34,719) $ (35,413) $ (36,121) $ (36,844) $ (37,581) $ (38,332) $ (39,099) $ (39,881) $ (40,679) $ (41,492) $ (42,322) $ (43,168) (Comm Vacancy) $ - $ - $ - $ - $ - $ - $ - $ - $ - $ - $ - $ - $ - $ - $ - (Other Vacancy) $ (420) $ (420) $ (420) $ (420) $ (420) $ (420) $ (420) $ (420) $ (420) $ (420) $ (420) $ (420) $ (420) $ (420) $ (420) Effective Gross Income $ 440,240 $ 448,933 $ 457,800 $ 466,844 $ 476,070 $ 485,479 $ 495,077 $ 504,867 $ 514,853 $ 525,039 $ 535,428 $ 546,025 $ 556,834 $ 567,859 $ 579,104 Operating Expenses Total Admin (Less PM Fee) $ 21,000 $ 21,630 $ 22,279 $ 22,947 $ 23,636 $ 24,345 $ 25,075 $ 25,827 $ 26,602 $ 27,400 $ 28,222 $ 29,069 $ 29,941 $ 30,839 $ 31,764 Property Manager Fee 6% $ 28,043 $ 28,603 $ 29,175 $ 29,759 $ 30,354 $ 30,961 $ 31,580 $ 32,212 $ 32,856 $ 33,513 $ 34,184 $ 34,867 $ 35,565 $ 36,276 $ 37,002 Total Utilities Expenses $ 10,000 $ 10,300 $ 10,609 $ 10,927 $ 11,255 $ 11,593 $ 11,941 $ 12,299 $ 12,668 $ 13,048 $ 13,439 $ 13,842 $ 14,258 $ 14,685 $ 15,126 Total O&M Expenses $ 14,500 $ 14,935 $ 15,383 $ 15,845 $ 16,320 $ 16,809 $ 17,314 $ 17,833 $ 18,368 $ 18,919 $ 19,487 $ 20,071 $ 20,674 $ 21,294 $ 21,933 Total Payroll $ 125,000 $ 128,750 $ 132,613 $ 136,591 $ 140,689 $ 144,909 $ 149,257 $ 153,734 $ 158,346 $ 163,097 $ 167,990 $ 173,029 $ 178,220 $ 183,567 $ 189,074 Real Estate Taxes $ 41,000 $ 42,640 $ 44,346 $ 46,119 $ 47,964 $ 49,883 $ 51,878 $ 53,953 $ 56,111 $ 58,356 $ 60,690 $ 63,118 $ 65,642 $ 68,268 $ 70,999 Property and Liability Insurance $ 12,500 $ 12,875 $ 13,261 $ 13,659 $ 14,069 $ 14,491 $ 14,926 $ 15,373 $ 15,835 $ 16,310 $ 16,799 $ 17,303 $ 17,822 $ 18,357 $ 18,907 Fidelity Bond Insurance $ - $ - $ - $ - $ - $ - $ - $ - $ - $ - $ - $ - $ - $ - $ - Lease $ - $ - $ - $ - $ - $ - $ - $ - $ - $ - $ - $ - $ - $ - $ - Total Operating Expenses $ 252,043 $ 259,733 $ 267,666 $ 275,847 $ 284,286 $ 292,991 $ 301,970 $ 311,232 $ 320,787 $ 330,643 $ 340,810 $ 351,300 $ 362,121 $ 373,286 $ 384,804 Replacement Reserve $ 15,000 $ 15,450 $ 15,914 $ 16,391 $ 16,883 $ 17,389 $ 17,911 $ 18,448 $ 19,002 $ 19,572 $ 20,159 $ 20,764 $ 21,386 $ 22,028 $ 22,689 Net Operating Income $ 173,197 $ 173,749 $ 174,221 $ 174,606 $ 174,901 $ 175,099 $ 175,196 $ 175,187 $ 175,065 $ 174,824 $ 174,459 $ 173,961 $ 173,326 $ 172,545 $ 171,611 Debt Service - First Mortgage $ 145,544 $ 145,544 $ 145,544 $ 145,544 $ 145,544 $ 145,544 $ 145,544 $ 145,544 $ 145,544 $ 145,544 $ 145,544 $ 145,544 $ 145,544 $ 145,544 $ 145,544 Debt Service - Second Mortgage $ - $ - $ - $ - $ - $ - $ - $ - $ - $ - Cashflow After Debt Service $ 27,653 $ 28,206 $ 28,677 $ 29,062 $ 29,357 $ 29,555 $ 29,653 $ 29,643 $ 29,521 $ 29,280 $ 28,915 $ 28,418 $ 27,782 $ 27,001 $ 26,067 Debt Service Coverage Ratio (1st and 2nd Mortgage) 1.19 1.19 1.20 1.20 1.20 1.20 1.20 1.20 1.20 1.20 1.20 1.20 1.19 1.19 1.179 Expense Coverage Ratio 1.65 1.63 1.61 1.60 1.58 1.56 1.55 1.53 1.52 1.50 1.48 1.47 1.45 1.44 1.42 Deferred Developer Fee Payment $ 27,653 $ 28,206 $ 28,677 $ 29,062 $ 29,357 $ 29,555 $ 89
You can also read