Catalogue www.breathingbuildings.com - Breathing Buildings
←
→
Page content transcription
If your browser does not render page correctly, please read the page content below
2 Breathing Buildings is the UK’s leading natural and hybrid ventilation company - home of the E-Stack and NVHR mixing ventilation systems that are changing the world When we started the company back in 2006 you had a choice between cold draughts and wasteful pre-heating of air. Our patented E-Stack mixing ventilation products and strategy, allied to smart controls and superb engineering has changed that forever. The benefits of mixing ventilation are now so clear that they have been written into regulations, a testimony to the evidence we can show you of making it work. Our catalogue is intended to make it easier for you to choose the right ventilation system, we hope it helps. Please get in touch with us so that we can show you our systems at work delivering superb indoor environments. It is something we are incredibly proud of and we want your building project to be just as successful. At Breathing Buildings that means supporting you from initial design right through to making sure it works as you expect. Let us prove it to you. Come and visit one of our buildings and allow us to help you with yours.
Breathing Buildings | Overview 3 Contents Introduction Case Studies and 06 Breathing Buildings Thought Leadership 08 What Is Natural Ventilation? Case Studies 09 Why Use Natural Ventilation? 44 Linton Village College 46 Hammerson Retail Control Strategy and Options 48 Asda Langley Mill 10 Control Strategies 50 Houghton-Le-Spring Primary Care Centre 11 Ventilation Systems 52 Barnfield Village College 12 Our Product Solutions Thought Leadership 54 The Science of Cold Draughts E-Stack Mixing ® 56 Thermal Modelling, WaterBath Ventilation Systems Modelling and CFD 58 Building Bulletin 101 - User Guide R Series S Series 66 Modelling Ventilation in IES 15 Product Information 19 Product Information 67 The Breathing Buildings Difference 17 Performance 23 Performance & Installation & Installation 17 System 23 System Schematic & Wiring Schematic & Wiring A Series F Series 25 Product Information 29 Product Information 27 Installation 31 Performance 27 System & Installation Schematic & Wiring 31 System Schematic & Wiring Passive Ventilation 33 Product Information 36 Roof Terminals 41 Dampers 42 Passive Stack Ventilation
4 • Superb internal climate • World leaders in winter mixing ventilation • CO2 and temperature monitoring • Summer purge and night cool • Reduce heating bills by up to 50% a year
Breathing Buildings | Overview 5 Breathing Buildings is the leading solutions provider in the field of Natural and Hybrid Ventilation. We offer you a full turnkey service and a selection of services to suit your needs. 1. Advisory Services • Expert consultation on natural and hybrid ventilation 2. Design Services • Dynamic thermal modelling • Computational fluid dynamics • Water bath modelling • Design responsibility with full PI cover 3. Product Solutions • Products to meet your criteria • Fully automatic controls or manual controls • Integration with other building systems including BMS, HVAC and heating 4. Installation Support 5. Commissioning and User Training 6. Service • Maintenance, Software Upgrades Extended Warranty 7. Monitoring Let us help you change the world... 01223 450060 www.breathingbuildings.com
6 Breathing Buildings Breathing Buildings is the UK’s leading low energy ventilation company – a spinout from Cambridge University that is changing the world of natural ventilation What We Do For Our Clients E-Stack Mixing Ventilation A research programme at Cambridge Our Mission is Simple University created a new concept for We aim to help clients create the lowest energy building possible ventilation that combines the principles with minimum associated CO2 emissions and capital cost, whilst of natural mixing ventilation in winter providing appropriate levels of ventilation and thermal comfort and natural upward displacement at all times of the year. We do this through our range of innovative ventilation in summer. This was patented in 2005 and the company ventilation products and through our unique design consulting. was set up to develop an easy-to-install system derived from the patent, and to Natural and Hybrid Ventilation Products provide the resulting E-Stack product • E-Stack Mixing Ventilation (p15) range to the industry. • Passive Stack Ventilation (p42) Design Consulting • Online Design Tools • Dynamic Thermal Modelling • Computational Fluid Dynamics • Water Bath Modelling • All design work covered by Professional Indemnity Insurance Installation and After Sales Support We offer a turnkey solution for our clients, including: • Design support throughout the project • In-room user interface Summer Strategy • BMS integration Upwards Displacement Ventilation • Installation • Final inspection • Service and maintenance contracts • Ongoing monitoring We will work with you from start to finish to ensure a successful project. Winter Strategy Mixing Ventilation
Breathing Buildings | Overview 7 We have projects all over the country so let us take you to one near you: Seeing is Believing Samuel Lister Academy Yorks PSBP is one of the first UK schools to make use of the NVHR+ enhanced natural ventilation system. The NVHR+ heater pod variant incorporates a ‘Low Temperature Hot Water’ heating coil, and is an example of Breathing Buildings’ continued product development. The BB team worked closely with the architect and main contractor to develop a precisely-tailored solution for the needs of this development. YMCA East Anton is a purpose-built nursery for 0-5 year olds which opened in October 2017. At early design stage it was suggested that the classrooms should have mechanical ventilation systems. However, YMCA had concerns about the energy use as well as maintenance costs associated with a mechanical ventilation scheme. Breathing Buildings were approached by Darcy Construction to design a natural ventilation system that would be unobtrusive and provide high levels of ventilation to keep the rooms fresh. St Raphael’s Primary School in London features a low-energy ventilation solution designed by Breathing Buildings for a new teaching block. The building, completed in January 2015, includes a double-height dance/activity hall (ventilated with e-stack S1500 units), three ground floor classrooms (ventilated with NVHR units) and three first floor classrooms (ventilated with e-stack R-Series units). Awards See our website for a list of Awards which Breathing Buildings and our clients have won Call us now and find out how we can help: Find a project near you: www.breathingbuildings.com/projects 01223 450060
8 What Is Natural Ventilation? Natural Ventilation is the process of using natural air movement, caused by the effects of wind and buoyancy, to provide fresh air into buildings In its simplest form natural ventilation Breathing Buildings has significant experience helping teams to design both simple buildings and is opening windows to allow air into complicated spaces. and out of a room. This solution might be appropriate if the requirements are By understanding these factors and sizing the simply “some” fresh air in the immediate system correctly we can design a natural ventilation proximity of the window. Our products can system that provides appropriate air flow without the need for a mechanical system. Most building help address the other factors which are types are suitable for natural ventilation including important to a successful natural ventilation homes, offices, schools, theatres and healthcare system; these include: centres. Natural ventilation also works with acoustic constraints and we have designed systems that Winter Mixing - avoiding cold draughts work under flight paths and next to motorways. in colder weather: Our patented E-Stack Mixing Ventilation system actively mitigates cold draughts using a duct temperature We do not leave you once sensor and control strategies developed our systems are installed - we over the last ten years. offer an ongoing maintenance Thermal Comfort - preventing and extended warranty overheating in hotter conditions: Our service unparalleled technical expertise ensures that the system is correctly sized. The E-Stack systems incorporate night cooling as standard to make the most of the thermal mass of a building. We can back this up by taking on design responsibility supported by Professional Indemnity insurance. Heat Gains and Occupancy - designing a system that responds to conditions in the room and outside: We actively monitor and respond to the temperature and CO2 levels in a room, with our control strategy ensuring the right ventilation strategy at all times.
Breathing Buildings | Overview 9 Why Use Natural Ventilation? The built environment accounts for around 45% of the energy consumption in developed countries Naturally ventilated buildings use 60% less energy than a traditional mechanically ventilated air conditioned building Winter Summer The E-Stack Mixing Ventilation system saves energy The E-Stack Ventilation system uses buoyancy and in winter by avoiding the wasteful pre-heating required wind effects to allow air to move through the building in other systems. This cuts heating bills and saves without using electrical energy to push the air. you money. E-Stack also includes a night cooling strategy that Natural ventilation avoids the electrical energy takes advantage of cooler night air to cool the fabric required by MVHR systems to force air through high of the building. This keeps the building cooler for resistance heat exchangers, cutting electricity bills and longer removing the need for air conditioning and saving money. saving you money. We are very hopeful that this unique approach will deliver carbon emission savings and energy cost savings in excess of any we could achieve using either mechanical or traditional natural ventilation systems Asda, Head of Corporate Sustainability, Julian Walker Palin
10 Control Strategy 01 Mixing Ventilation • Patented ventilation strategy • Pre-mixes incoming fresh air with room air to mitigate cold draughts • Monitors internal and external temperature, and temperature of mixed air • Responds to CO2 in the room • Reduces heating bills 02 Displacement Ventilation • Buoyancy and wind driven flow • Maximum stack effect when combined with low level openings • Monitors internal and external temperature • Responds to CO2 and temperature in the room 03 Night Cooling • Provided through secure openings • Buoyancy and wind driven flow • Cools fabric down overnight to provide convective and radiative cooling the following day • Fan boost function at 3am on warm nights to ensure fabric is cooled • Monitors internal and external temperature 04 Summer Boost • Fan-assisted ventilation on hottest days • Monitors internal and external temperature 05 Heating Control • Patented system • Local control of radiator valve or underfloor heating manifold • Ensures ventilation system integrates with the heating system • Minimises heating bills
Breathing Buildings | Control Strategies and Options 11 Ventilation Systems Roof Mounted Ventilation Page 14 to 23 • Patented mixing system for draught mitigation • Passive stack option for taller spaces or where draughts are not a problem • Mushroom cowl or penthouse louvre terminals • Damper, internal grilles and mixing system • Acoustic attenuation option for noisy sites • R Series or S Series options E-Stack® Mixing Ventilation Atrium Ventilation Page 24 to 27 • A500 and Passive options • High level automated windows and/or dampers in atrium • In - and outflow through high level vents, and transfer to occupied rooms through A Series units • Rooms with lower heat gain benefit from rooms with higher heat load to minimise heating bills • Acoustic attenuation option for noisy sites Facade Ventilation Page 28 to 31 • Patented mixing system for draught mitigation • F500, F1000 options • Louvre, damper, internal grilles and mixing system • Acoustic attenuation option for noisy sites • Can be combined with passive attenuators to link to atrium System Components Page 32 to 42 Passive Ventilation • Louvres • Dampers • Grilles • Acoustic attenuators • Mechanical Ventilation
12 Our Product Solutions Smart design is important but we want to change the world of ventilation and we have the product range to help you Control Options Occupancy NV Smart + NV Smart + Connected Connected Stackvent Stackvent NV Smart Without per unit Control Control Manual Type R Series 10-35 Stack • • • S1500 35-100 Stack • • • Roof Units S1200 10-35 Stack • • • S1000 10-17 Stack • • • Atrium A500 10-35 Cross flow • • F1000 10-35 Façade • • • Façade F500 10-17 Façade • • • NVHR 10-17 Façade • • • • NVHR NVHR+* 10-17 Façade • PS600 Design Stack • • • • PS800 Design Stack • • • • PS1000 Design Stack • • • • Passive Stack PS1200 Design Stack • • • • PS1500 Design Stack • • • • PSR Design Stack • • • • *Heating control is included Strategy Integration Actuated auxillary Actuated window Actuated window Summer Boost / damper control Winter Mixing Displacement control and Integration Ventilation Night Cool and power Mitigation Interlock Interlock Strategy Draught Cooling Heating Heating Control Natural control power Purge BMS NV Smart • • • • • NV Smart + • • • • • • • ° • ° ° NV Smart + Connected • • • • • • • • ° • ° ° Stackvent • • Stackvent Connected • • • ° Manual Control • Without control • Key: • Comes as standard ° Option at additional cost
LED Natural Unit Colours ° ° ° ° ° ° ° • • • Ventilation Available Interface Penthouse • • • • • • • • • • Roof Terminal • • • • • • • Keyswitch Triple Bank ° ° ° ° ° ° ° ° ° ° Penthouse Boost / Purge ° ° ° Button Mushroom • • • • • • • • • • Roof Terminal Room • • • • • • Temp /CO2 Terminal ANY ° ° ° ° ° ° ° ° ° ° Standard RAL Ancillaries External Temp • • • • • Acoustic • ° ° ° ° ° ° ° ° ° ° ° ° ° ° Sensor Attenuation Egg Crate • • • • • • • • • • • • • Wind Sensor • • Unit Options Grilles Interface Full control details are available on our website www.breathingbuildings.com/products Ball Proof ° ° ° ° ° ° ° ° ° ° ° ° ° Rain Sensor Grilles • • Interface Tamper Proof ° ° ° ° ° ° ° ° ° ° ° ° ° Grilles Remote ° Monitoring CAD Drg. • • • • • • • • • • • • • • • Available Spring Return • • • • Actuator Service ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° Contract • • Mechanical Fire Interface Close on Signal ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° Install Breathing Buildings | Control Strategies and Options 13
14 The R Series unit is a ceiling mounted unit that has been designed to... ventilate a room with occupancies from 10-35 people. The split shaft provides inflow and outflow in winter and combines with opening windows in the summer to create a stack effect. Integrated fans mitigate cold draughts in a low energy way delivering appropriate ventilation and superb thermal comfort with fan boost and night cooling as standard.
Breathing Buildings | R Series 15 R Series The R Series is one of our most popular units. Designed for a space the size of a standard 55-65m2 room, ventilation is provided through a split shaft giving access to the roof Product Information Features • Low energy mixing fans to mitigate against cold draughts in winter • Summer exhaust boost mode • Night cooling Air Flow Strategies • Insulated volume control damper ensures appropriate ventilation rates • Internal temperature sensor with integrated Summer Mode CO2 sensor When it is warm outside the system operates in upflow displacement mode, using the stack effect • External temperature sensor to achieve high air flow rates and keep the room at a • Integral control responds to environmental pleasant temperature. conditions • Ready fitted mounting brackets Fan boost and night cooling modes offer greater • Three choices of mixed air delivery direction thermal comfort in exceptional summer conditions. • Key switch for automatic operation; test; off Options • Penthouse louvre or mushroom terminal • Integrated noise attenuation unit offering 33dB Dnew for noisy sites, more available on request • Patented heating control strategy ensures minimum energy use Winter Mode • Control signal for automated actuation of low When the outside temperature becomes too low to bring level windows or dampers directly onto the occupants the R Series unit operates • Modbus link for integration into wider as inflow and outflow. The fans in the unit pre-mix the Building Management Systems (BMS) incoming air with air from within the room, preventing the • Eggcrate grilles need for wasteful pre-heating.
16 R Series continued R Series Dimensioned Drawing PRINTED 12/ DO NOT SCALE 4X ANGLE BRACKETS IF IN DOUBT, ASK! REFER TO DRAWING PLAN VIEW ACTUATOR 1505-9000 DAMPER COVER REVISIONS 1088 TO BRACKET HOLE CL REV. DESCRIPTION DATE DRA A CE 1 FIRST ISSUE 05/03/2015 C 14 AN 2 NOTES 04/04/2015 D 1004 TO BRACKET HOLE CL AR C LE 3 NOTES 25/06/2015 C CL F OR NEOPRENE 4 UPDATED 12/08/2016 C "C" SIDE STRIP WEIGHT VERTICAL SEALING DIVIDER TO BE NOTES: FACE 1545 TO BRACKET HOLE CL ALIGNED WITH 1588 ACROSS BRACKETS 1. R-SERIES UNIT SIMILAR DIVIDER B IN SHAFT AND FINISHED IN GALV. AS STANDARD. RAL ROOF TERMINAL R-SERIES SHOWN COLOURS AVAILABLE DURING IN-CONTEXT OF ON REQUEST AT INSTALLATION ADDITIONAL COST. INSTALLATION WITH 2. MIXED AIR DELIVERY TO CREATE TWO GRP MUSHROOM ROOF "A" SIDE AIR PATHWAYS OUTLET THROUGH "B" "B" SIDE TERMINATION TO SIDE AS STANDARD. SHOWN WITH SHOW VERTICAL 3. UNIT SUPPLIED WITH MIXED AIR DELIVERY OPEN NO. MOUNTING DIVIDER. BRACKETS AS SHOWN AS STANDARD. CONTROL BOX LOCATION REFER TO 4. UNIT CAN BE HUNG INSTALLATION FROM M10 STUDDING DO NOT DRILL THROUGH 2 THROUGH FIXING C THIS AREA - ACCESS FOR DRAWINGS FOR Up-stand must DIMENSIONS AND BRACKETS. CABLES TO LEFT SIDE OF be level 5. UNIT SHOWN WITHOU SPACE ENVELOPE INSTALL DETAIL. GRILLES. GRILLES AVAILABLE ON (500X500) REQUEST AT ADDITIONAL COST. 6. IF UNIT IS POSITIONED LESS THAN 2.7m 1600 950 ABOVE GROUND, FINGER GUARD OVERALL OVERALL GRILLES MUST BE USED. 1128 ACROSS BRACKETS 1536 875 7. DIVIDER TO BE DAMPER DAMPER ALIGNED WITH SIMILAR D A DIVIDER IN SHAFT AND ROOF TERMINAL DURING INSTALLATION TO CREATE TWO AIR 2 PATHWAYS. 8. DAMPER PHYSICAL 204 ENSURE FREE AREA 0.82M^2. GOOD 9. DAMPER FINISH RAL SEALING 9005 GLOSS 70. 605 500 400 FACE E 800 500 75 A CONTROL BOX TWIN FANS IN MIXING "B" SIDE "A" SIDE CHAMBER (SHOWN WITH MIXED AIR DELIVERY OPEN) (SHOWN WITH MIXED AIR DELIVERY CLOSED) SECTION A-A 850 F MATERIAL: MILD STEEL FINISH GALV. OR POWDER COAT ZINTEC C MASS WITHOUT PACKAGING 106KG FAN HUB TOLERANCES EXCEPT WHERE OTHERWISE ST X 0.5MM MIXED AIR DELIVERY: X.XX ANGLES 0.05MM 0.5 SURFACE TEXTURE TO BE 1.6 UMRA OR BETT AVAILABLE HANDINGS IN PLAN VIEW 1440 B DE-BURR ALL SHARP EDGES AND HOLES VERTICAL (DAMPER REMOVED FOR CLARITY) ITEM MUST BE FREE FROM SCRATCHES, DENT G OTHER BLEMISHES. DIVIDER DIMENSIONS IN MILLIMETRES SIDE B OPEN AS DEFAULT A UNIT 3A, THE SHADE, SOHAM, CB7 5HF T: 01223 450060 F: 01223 450061 www.breathingbuildings.com/products TITLE: CONTROL E-STACK: R-SERIES VERSIO BOX 6 H ACTUATOR DRAWING NO: MAINTENANCE UNDERSIDE VIEW FROM 1332_9201 UNDERSIDE OF E-STACK REV DRAWN DATE CHK'D DA 4 CC 12/08/2016 1 2 3 4 5 6 7 8 9 10 11 SCALE 1:15 A2 SHEET 1 O CONFIDENTIAL: THIS DOCUMENT IS FOR THE USE OF THE MAIN CONTRACTOR, ARCHITECT, M&E DESIGN CONSULTANT AND M&E SUBCONTRACTOR FOR THE PROJECT NAMED IN THIS DOCUMENT OR ACCOMPANYING CORRESPONDENCE. THE CONTENTS SHOULD NOT BE DISCLOSED TO THIRD PARTIES, INCLUDING OTHER EQUIPMENT SUPPLIERS WITHOUT THE PRIOR CONSENT OF BREATHING BUILDINGS. BREATHING BUILDIN BREATHING BUILDINGS RESERVE THE RIGHT TO CHANGE PRODUCT DESIGN WITHOUT PRIOR NOTI Dimensions Electrical SECTION A-A H 500 mm Power Rating 0.1 kW D 950 mm Voltage 230V AC (+- 10%) W 1,600 mm Full load current 0.5A Weight 110 kg Short Circuit Rating N/A - Control only Physical area 0.75 m 2 Earth Leakage
Breathing Buildings | R Series 17 Performance Installation The R Series comes with fixing brackets. U-Value Part L2a requirement 3.5 (W/m2 K) The E-Stack unit can be hung from 4 no. pieces R Series 2.2 (W/m2 K) of M10 (drop rods). Damper section
18 The S Series unit is a ceiling mounted unit that comes in 3 sizes S1500, S1200 and S1000 The S1500 has been designed to ventilate a room with occupancies from 35 to 100 people, the S1200 for spaces with occupancies of 15 to 35. S1000 units are suitable for spaces with lower heat gains or when operating as multiple units. For larger spaces multiple S Series units are installed and can be controlled independently or in zones.
Breathing Buildings | S Series 19 S Series The S Series is designed for larger spaces such as school halls, theatres or rooms with high occupancy. Ventilation is provided through a split shaft giving access to the roof The split shaft for the S1500L and S1200L provides inflow and outflow in winter and can combine with opening windows or dampers in the summer to create a stack effect. Integrated fans mitigate cold draughts in a low energy way delivering appropriate ventilation and superb thermal comfort as well as providing fan boost and night cool functionality. Product Information Features • Low energy mixing fans to mitigate against cold Air Flow Strategies draughts in winter • Summer exhaust boost mode Summer Mode • Night cooling When it is warm outside the system operates in upflow • Insulated volume control damper ensures displacement mode, using the stack effect to achieve high appropriate ventilation rates air flow rates and keep the room at a pleasant temperature. • Internal temperature sensor with integrated Fan boost and night cooling modes offer greater thermal CO2 sensor comfort in exceptional summer conditions. • External temperature sensor • Integral control responds to environmental conditions • Traffic light indicator panel for window opening • Ready fitted mounting brackets • Three choices of mixed air delivery direction • Key switch for automatic operation; test Options • Low level control panel • Penthouse louvre or mushroom terminal Winter Mode • Integrated noise attenuation unit offering 35dB Dnew When the outside temperature becomes too low to bring for noisy sites, more available on request directly onto the occupants the S Series unit operates • Patented heating control strategy ensures minimum as inflow and outflow. The fans in the unit pre-mix the energy use incoming air with air from within the room, preventing • Control signal for automated actuation of low level the need for wasteful pre-heating. windows or dampers • Modbus link for integration into wider Building Management Systems (BMS) • Eggcrate grilles
20 S Series continued S1500 Dimensioned Drawing PRINTED 11/08/2016 DO NOT SCALE ISOMETRIC IF IN DOUBT, ASK! PLAN VIEW REVISIONS REV. DESCRIPTION DATE DRAWN A DAMPER 1 ADDED SHEET 2 01/08/ CC 2016 14 FOR CLEARANCE 1629 CL CL 1713 1753 4X ANGLE BRACKETS REFER TO DRAWING NOTES 1505_9000 1. GRILLES AVAILABLE AT B ADDITIONAL COST. NEOPRENE CONTROL 2. DAMPER PHYSICAL FREE AREA APPROX. 1.52M^2. RUBBER SEAL PANEL BONDED TO COVER - FIXING TOP OF UNIT DO NOT BRACKET OBSTRUCT 1522 CL ACCESS 1565 1575 1575 C 1200 1487 1487 210 502.60 300 GRILLE ACROSS DAMPER ACROSS DAMPER 57 106 50 GRILLE 500 209 400 MATERIAL: B A MILD STEEL SIDE OPEN FOR SIDE OPEN FOR D MIXED AIR DELIVERY MIXED AIR DELIVERY FINISH GALV. OR ZINTEC POWDER COATED MASS WITHOUT PACKAGING 1425 131KG GRILLE TOLERANCES EXCEPT WHERE OTHERWISE STATED A X 0.5MM 300 X.XX 0.05MM ANGLES 0.5 SURFACE TEXTURE TO BE 1.6 UMRA OR BETTER DE-BURR ALL SHARP EDGES AND HOLES ITEM MUST BE FREE FROM SCRATCHES, DENTS AND OTHER BLEMISHES. DIMENSIONS IN MILLIMETRES E GRILLE 1425 B UNIT 3A, THE SHADE, SOHAM, CB7 5HF T: 01223 450060 F: 01223 450061 FANS www.breathingbuildings.com/products TITLE: 300 E-STACK: S1500L VERISON 3 REVERSE ISOMETRIC DRAWING NO: F UNDERSIDE 1510_9001 REV DRAWN DATE CHK'D DATE 1 CC 01/08/2016 1 2 3 4 5 6 7 SCALE 1:30 A3 SHEET 1 OF 2 CONFIDENTIAL: THIS DOCUMENT IS FOR THE USE OF THE MAIN CONTRACTOR, ARCHITECT, M&E DESIGN CONSULTANT AND M&E SUBCONTRACTOR FOR THE PROJECT NAMED IN THIS DOCUMENT OR ACCOMPANYING CORRESPONDENCE. THE CONTENTS SHOULD NOT BE DISCLOSED TO THIRD PARTIES, INCLUDING OTHER EQUIPMENT SUPPLIERS WITHOUT THE PRIOR CONSENT OF BREATHING BUILDINGS. BREATHING BUILDINGS LTD ©. BREATHING BUILDINGS RESERVE THE RIGHT TO CHANGE PRODUCT DESIGN WITHOUT PRIOR NOTIFICATION. Dimensions Electrical H 500 mm Power Rating 0.1 kW D 1,500 mm Voltage 230V AC (+- 10%) W 1,500 mm Full load current 0.5A Weight 168 kg Short Circuit Rating N/A - Control only Physical area 1.54 m 2 Earth Leakage
Breathing Buildings | S Series 21 S1200 Dimensioned Drawing PRINTED 11/08/2016 DO NOT SCALE IF IN DOUBT, ASK! DAMPER REVISIONS REV. DESCRIPTION DATE DRAWN A 1 FIRST ISSUE 04/06/2015 CC PLAN VIEW 2 UPDATE WEIGHT 11/08/2016 CC FIXING BRACKET NOTES: 1. UNIT SUPPLIED WITH 4 NO. FIXING BRACKETS CL 1413 CL 1329 2. E-STACK CAN BE HUNG FROM 4 NO. M10 STEEL THREADED STUDDING B 3. FINISH - GALV. AS STANDARD (RAL AT ADDITIONAL COST) 4. GRILLES NOT SHOWN. GRILLES SUPPLIED AT ADDITIONAL COST 5. IF UNIT IS POSITIONED LESS "D" SIDE "C" SIDE THAN 2.7M ABOVE FINISH FLOOR LEVEL, FINGER GUARD GRILLES MUST BE USED SIDE C AND D OPEN FOR MIXED AIR CONTROL PANEL DELIVERY (SHOWN COVER PLATE CL 1220 WITHOUT GRILLES) C 1453 130 1275 1275 725 1125 1175 1175 222 BREATHING BUILDINGS CONTINUOUSLY WORK TO IMPROVE OUR PRODUCTS. TO ENSURE UP TO DATE DRAWINGS, PLEASE CONTACT BREATHING BUILDINGS 310 CL 500 400 MATERIAL: MILD STEEL D FINISH GALV. OR ZINTEC POWDER COATED "D" SIDE "C" SIDE (OPEN FOR MIXED AIR DELIVERY) (OPEN FOR MIXED AIR DELIVERY) MASS WITHOUT PACKAGING 120KG TOLERANCES EXCEPT WHERE OTHERWISE STATED X 0.5MM X.XX 0.05MM ANGLES 0.5 SURFACE TEXTURE TO BE 1.6 UMRA OR BETTER 1125 DE-BURR ALL SHARP EDGES AND HOLES ITEM MUST BE FREE FROM SCRATCHES, DENTS AND OTHER BLEMISHES. D DIMENSIONS IN MILLIMETRES E PLAN VIEW UNIT 3A, THE SHADE, SOHAM, CB7 5HF T: 01223 450060 F: 01223 450061 1125 www.breathingbuildings.com/products C MIXED AIR DELIVERY TITLE: E-STACK: S1200L VERSION 1 DRAWING NO: F 1341_9002 UNDERSIDE VIEW REV DRAWN DATE CHK'D DATE 2 CC 11/08/2016 1 2 3 4 5 6 7 SCALE 1:22 A3 SHEET 1 OF 1 CONFIDENTIAL: THIS DOCUMENT IS FOR THE USE OF THE MAIN CONTRACTOR, ARCHITECT, M&E DESIGN CONSULTANT AND M&E SUBCONTRACTOR FOR THE PROJECT NAMED IN THIS DOCUMENT OR ACCOMPANYING CORRESPONDENCE. THE CONTENTS SHOULD NOT BE DISCLOSED TO THIRD PARTIES, INCLUDING OTHER EQUIPMENT SUPPLIERS WITHOUT THE PRIOR CONSENT OF BREATHING BUILDINGS. BREATHING BUILDINGS LTD ©. BREATHING BUILDINGS RESERVE THE RIGHT TO CHANGE PRODUCT DESIGN WITHOUT PRIOR NOTIFICATION. Dimensions Electrical H 500 mm Power Rating 0.1 kW D 1,200 mm Voltage 230V AC (+- 10%) W 1,200 mm Full load current 0.5A Weight 130 kg Short Circuit Rating N/A - Control only Physical area 0.96 m 2 Earth Leakage
22 S Series continued S1000 Dimensioned Drawing PRINTED 29/07 DO NOT SCALE PLAN VIEW IF IN DOUBT, ASK! REVISIONS A SIDE "D" CONTROL BOX REV. DESCRIPTION DATE DRAWN FOR MIXED AIR DELIVERY NOTES: 1. Unit finished in galv. mild steel. RAL colours available on reques CL 950 at additional cost. 2. Mixed air delivery outlet through side "B" as standard (see diagra "A"). To be confirmed by custom B at order stage. 3. Unit supplied with 4 no. fixing brackets. 4. Unit can be hung from M10 studding through fixing brackets. 14 5. Unit shown without grilles. Grille available on request at additiona FIXING SIDE "B" cost. CL 1110 BRACKET 6. If unit is positioned less than 2.7 OPEN FOR MIXED above ground, finger guard grille must be specified. AIR DELIVERY 7. E-stack must be installed on the horizontal plane. 1050 1050 8. Weight (without pallet, damper and grilles) - approx. 40kg. 950 950 130 C 890 DAMPER DAMPER CL 145 229 400 500 425 TOLERANCES EXCEPT WHERE OTHERWISE STAT SIDE "B" 470 SIDE "D" X X.XX 0.5MM 0.05MM D (MIXED AIR DELIVERY HANDING (MIXED AIR DELIVERY HANDING ANGLES 0.5 SHOWN OPEN) SHOWN CLOSED) SURFACE TEXTURE TO BE 1.6 UMRA OR BETTER DE-BURR ALL SHARP EDGES AND HOLES ITEM MUST BE FREE FROM SCRATCHES, DENTS A OTHER BLEMISHES. DIMENSIONS IN MILLIMETRES 890 UNIT 3A, THE SHADE, SOHAM, CB7 5HF T: 01223 450060 F: 01223 450061 WWW.BREATHINGBUILDINGS.COM TITLE: E DIAGRAM "A" E-STACK: S1000 VERSION 1 (F1000 MIXED AIR DELIVERY WITH INTEGRATED DAMPER) 890 B D DIAGRAM LEFT SHOWS AVAILABLE HANDING FOR MIXED AIR DELIVERY - PLAN DRAWING NO: VIEW 1410_9002_01 MATERIAL: MILD STEEL F FINISH: UNDERSIDE VIEW GALV. OR POWDER COAT ZINTEC REV DRAWN DATE CHK'D DATE 1 CC 29/07/2015 1 2 3 4 5 6 7 SCALE 1:20 A3 SHEET 1 OF 2 CONFIDENTIAL: THIS DOCUMENT IS FOR THE USE OF THE MAIN CONTRACTOR, ARCHITECT, M&E DESIGN CONSULTANT AND M&E SUBCONTRACTOR FOR THE PROJECT NAMED IN THIS DOCUMENT OR ACCOMPANYING CORRESPONDENCE. THE CONTENTS SHOULD NOT BE DISCLOSED TO THIRD PARTIES, INCLUDING OTHER EQUIPMENT SUPPLIERS WITHOUT THE PRIOR CONSENT OF BREATHING BUILDINGS COPYR Dimensions Electrical BBL RESERVE THE RIGHT TO CHANGE PRODUCT DESIGN WITHOUT PRIOR NOTIFICAT H 500 mm Power Rating 0.1 kW D 1,000 mm Voltage 230V AC (+- 10%) W 1,000 mm Full load current 0.5A Weight 130 kg Short Circuit Rating N/A - Control only Physical area 0.96 m2 Earth Leakage
Breathing Buildings | S Series 23 Performance Installation U-Value The S Series comes with fixing brackets. Part L2a requirement 3.5 (W/m2 K) The E-Stack unit can be hung from 4 no. pieces S Series 2.2 (W/m2 K) of M10 (drop-rods). Damper section
24 In summer air is brought into the rooms through the opening facade vents or windows and is exhausted into the atrium through all of the A Series units
Breathing Buildings | A Series 25 A Series The A Series is designed for a standard school room or office where a corridor or atrium is used and which provides access to the exterior at high level. It is particularly helpful in multi-storey buildings where it is not feasible to create dedicated shafts through upper level rooms to provide air pathways to lower floors from the roof Air Flow Strategies Product Information Summer Mode Features When it is warm outside the system operates in • Low energy mixing fans to mitigate against cold upflow displacement mode, using the stack effect to draughts in winter achieve high air flow rates and keep the room at a • Summer exhaust boost mode pleasant temperature. • Acoustic attenuator to provide acoustic separation of atrium and occupied rooms Fan boost and night cooling modes offer greater thermal comfort in exceptional summer conditions. • Night cooling • Internal temperature sensor with integrated CO2 sensor • External temperature sensor • Networked, integral controllers report to central Atlas Control panel to respond to local conditions • Traffic light indicator panel for window opening • Ready fitted mounting brackets • Key switch for automatic operation; long term off; test Winter Mode When the outside temperature becomes too low to bring directly onto the occupants the A Series units operate in exchange mode. The building ventilates naturally by exchanging air naturally between the Options atrium and exterior. The occupied rooms exchange • A500 to fit ceiling void flow using low energy fans within the A Series units, • Penthouse louvre or mushroom terminal in atrium preventing the need for wasteful preheating of fresh air. • Actuated windows or dampers in atrium • Noise attenuation for noisy sites • Patented heating control strategy ensures minimum energy use • Control signal for automated actuation of low level windows or dampers • Modbus link for integration into wider Building Management Systems (BMS) • Eggcrate grilles • Different attenuation levels to suit project requirements
26 A Series continued A500 Dimensioned Drawing DO NOT SCALE PRINTED 10/08/2016 IF IN DOUBT, ASK! REVISIONS REV. DESCRIPTION DATE DRAWN A PLAN VIEW 1 FIRST ISSUE 5/12/14 CC 2 UPDATED WEIGHT 10/08/2016 CC CL 1475 CL 1391 MOUNTING BRACKET B NOTES: CL 1640 1. FINISH - GALV. (STANDARD). RAL COLOURS AVAILABLE AT ADDITIONAL COST. 2. UNIT SUPPLIED PRE- ATRIUM SIDE ASSEMBLED WITH 4 NO. MOUNTING BRACKETS. 3. GRILLE NOT SHOWN. GRILLE AVAILABLE ON REQUEST AT 530 ADDITIONAL COST. C 1516 1810 BREATHING BUILDINGS CONTINUOUSLY WORK TO IMPROVE OUR PRODUCTS. TO ENSURE UP TO DATE DRAWINGS, PLEASE CONTACT BREATHING BUILDINGS 1338 ACOUSTIC ATTENUATOR 150 A 503 MATERIAL: MILD STEEL D A 99 FINISH GALV. (STD) OR POWDER COAT ZINTEC ROOM SIDE ATRIUM SIDE SECTION A-A MASS WITHOUT PACKAGING 185KG TOLERANCES EXCEPT WHERE OTHERWISE STATED 890 X X.XX 0.5MM 0.05MM ANGLES 0.5 SURFACE TEXTURE TO BE 1.6 UMRA OR BETTER DE-BURR ALL SHARP EDGES AND HOLES CONTROL ITEM MUST BE FREE FROM SCRATCHES, DENTS AND OTHER BLEMISHES. BOX DIMENSIONS IN MILLIMETRES E 890 UNIT 3A, THE SHADE, SOHAM, CB7 5HF T: 01223 450060 F: 01223 450061 1325 www.breathingbuildings.com/products TITLE: E-STACK: A500 VERSION 2 DRAWING NO: F 1418_9001 REV DRAWN DATE CHK'D DATE 2 CC 10/08/2016 1 2 3 4 5 6 7 SCALE 1:30 A3 SHEET 1 OF 1 CONFIDENTIAL: THIS DOCUMENT IS FOR THE USE OF THE MAIN CONTRACTOR, ARCHITECT, M&E DESIGN CONSULTANT AND M&E SUBCONTRACTOR FOR THE PROJECT NAMED IN THIS DOCUMENT OR ACCOMPANYING CORRESPONDENCE. THE CONTENTS SHOULD NOT BE DISCLOSED TO THIRD PARTIES, INCLUDING OTHER EQUIPMENT SUPPLIERS WITHOUT THE PRIOR CONSENT OF BREATHING BUILDINGS. BREATHING BUILDINGS LTD ©. BREATHING BUILDINGS RESERVE THE RIGHT TO CHANGE PRODUCT DESIGN WITHOUT PRIOR NOTIFICATION. Dimensions Electrical H 503 mm Power Rating 0.1 kW D 1,338 mm Voltage 230V AC (+- 10%) W 1,810 mm Full load current 0.5A Weight 174 kg Short Circuit Rating N/A - Control only Physical area 0.22 m2 Earth Leakage
Breathing Buildings | A Series 27 Installation The A Series comes with fixing brackets. The E-Stack unit can be hung from 4 no. pieces of M10 (drop-rods). Example installation prior to construction of bulkhead System Schematic and Wiring High level atrium openings Power Exterior Temperature Sensor 24VDC, 0-10V, BMS Panel Breathing Buildings Ground, SCN (Screen) (if present) Atlas Control Panel CAT 5 Modbus to BMS interface A Series A Series A Series Room #1 Room #2 Room #3 Optional modbus network #2 CAT5 Modbus network cable with Y splitters and RJ45 ends Modbus network #1 A Series A Series A Series Room #1 Room #2 Room #3 24vDC, 0v, 0-10V, 0-10V, screen CAT5 Modbus From atlas network To next A Series Room Atrium Power temperature and CO2 sensor 24vDC, 0v, 0-10V, 0-10V, screen e-stack: A Series “Parent” Room temperature and CO2 sensor 230VAC FORWARD, 230AC REVERSE, NEUTRAL, E OPEN TIMED WINDOWS ON AUTO MAX VENT WHEN LIT OFF TEST TIMED DISABLE e-stack: A Series “Child” Key switch A Series fitted room
28 The F Series is designed to allow rooms to ventilate through the facade
Breathing Buildings | F Series 29 F Series If there is a clerestory window concept as indicated in the figure shown then the unit operates in single sided mixing ventilation mode in winter and in summer uses displacement cross-flow ventilation. Without an elevated facade the F500 units provide mixing ventilation The F1000 unit is a facade mounted unit that has been designed to ventilate a room with occupancies from 10 to 35 people. Integrated fans mitigate cold draughts in Product Information a low energy way delivering appropriate ventilation and superb thermal comfort. The illustration below shows Features an F1000 unit located in a room with another variable • Low energy mixing fans to mitigate against cold control damper located on the same facade in the draughts in winter opposite corner of the room • Summer exhaust boost mode • Night cooling • Insulated volume control damper ensures appropriate ventilation rates • Internal temperature sensor with integrated CO2 sensor • External temperature sensor • Integral control responds to environmental conditions Air Flow Strategies • Indicator panel for window opening • Ready fitted mounting brackets Summer Mode • Key switch for automatic operation; long When it is warm outside the system operates in upflow term off; test displacement mode, using the stack effect to achieve high air flow rates and keeping the room at a pleasant Options temperature. • F1000 and F500 Fan boost and night cooling modes offer greater thermal • Patented heating control strategy ensures comfort in exceptional summer conditions. minimum energy use • Weather louvre Winter Mode • Noise attenuation for noisy sites When the outside temperature becomes too low to bring • Integrated noise attenuation through combination air directly onto occupants the F Series operates to pre- of acoustic louvres and internal baffles depending mix the incoming cold fresh air with warm room air to on site specific requirements mitigate the risk of cold draughts and eliminate the need for wasteful pre-heating with radiators. Exhaust is • Control signal for automated actuation of low provided by an adjacent window or variable control level windows or dampers damper provided by Breathing Buildings. • Modbus link for integration into wider Building Management Systems (BMS) • Eggcrate grilles Summer Winter
30 F Series continued F1000 Dimensioned Drawing PRINTED 12/08/2016 DO NOT SCALE PLAN VIEW IF IN DOUBT, ASK! REVERSE ISOMETRIC ISOMETRIC REVISIONS REV. DESCRIPTION DATE DRAWN A 1 FIRST ISSUE 27/10/2014 CC 2 MINOR UPDATE 29/09/2015 CC CONTROL BOX SIDE "D" 3 ADDED WEIGHT 11/08/2016 CC HOLES CENTRELINE NOTES: 1. UNIT FINISHED IN GALVANISED AS STANDARD. RAL COLOURS AVAILABLE ON 950 REQUEST AT ADDITIONAL COST. 2. MIXED AIR DELIVERY SUPPLY B THROUGH SIDE "B" AS DEFAULT (SEE DIAGRAM "A" FOR HANDING'S). TO BE CONFIRMED BY CUSTOMER AT ORDER STAGE. 3. UNIT SUPPLIED WITH 4 NO. MOUNTING BRACKETS. MOUNTING 4. UNIT SHOWN WITHOUT CL 1110 BRACKET SIDE "B" GRILLES. GRILLES AVAILABLE ON REQUEST AT ADDITIONAL HOLES CENTRELINE SHOWN OPEN COST. FOR MIXED 5. IF UNIT IS POSITIONED LESS THAN 2.7m ABOVE GROUND, AIR DELIVERY "FINGER GUARD" GRILLES (DEFAULT) MUST BE SPECIFIED. 6. WEIGHT APPROX. 40KG 1150 (EXCLUDING PALLET AND C 890 GRILLES). 145 1050 1050 7. ACCESS MUST BE PROVIDED GRILLE APERTURE TO CONTROL BOX, MINIMUM 600X600 ACCESS HATCH. GRILLE APERTURE BREATHING BUILDINGS CONTINUOUSLY WORK TO IMPROVE OUR PRODUCTS. TO ENSURE UP TO DATE DRAWINGS, PLEASE CONTACT BREATHING BUILDINGS 226 500 425 400 MATERIAL: MILD STEEL SIDE "B" CONTROL BOX SIDE "D" D (MIXED AIR DELIVERY COVER PLATE (MIXED AIR DELIVERY FINISH GALV. OR ZINTEC POWDER COATED SHOWN OPEN) SHOWN CLOSED) MASS WITHOUT PACKAGING 75KG TOLERANCES EXCEPT WHERE OTHERWISE STATED 890 X 0.5MM GRILLE APERTURE X.XX ANGLES 0.05MM 0.5 SURFACE TEXTURE TO BE 1.6 UMRA OR BETTER DE-BURR ALL SHARP EDGES AND HOLES ITEM MUST BE FREE FROM SCRATCHES, DENTS AND OTHER BLEMISHES. SIDE C GRILLE APERTURE DIMENSIONS IN MILLIMETRES E DIAGRAM "A" MIXED AIR DELIVERY HANDING'S 890 DIAGRAM LEFT SHOWS UNIT 3A, THE SHADE, SOHAM, CB7 5HF AVAILABLE HANDING FOR MIXED T: 01223 450060 F: 01223 450061 SIDE SIDE AIR DELIVERY (PLAN VIEW) www.breathingbuildings.com/products B D TITLE: E-STACK: F1000 (WITHOUT SIDE A INTEGRAL DAMPER) VERSION 1 DRAWING NO: F UNDERSIDE VIEW 1410_9001 REV DRAWN DATE CHK'D DATE 3 CC 11/08/2016 1 2 3 4 5 6 7 SCALE 1:20 A3 SHEET 1 OF 2 CONFIDENTIAL: THIS DOCUMENT IS FOR THE USE OF THE MAIN CONTRACTOR, ARCHITECT, M&E DESIGN CONSULTANT AND M&E SUBCONTRACTOR FOR THE PROJECT NAMED IN THIS DOCUMENT OR ACCOMPANYING CORRESPONDENCE. THE CONTENTS SHOULD NOT BE DISCLOSED TO THIRD PARTIES, INCLUDING OTHER EQUIPMENT SUPPLIERS WITHOUT THE PRIOR CONSENT OF BREATHING BUILDINGS. BREATHING BUILDINGS LTD ©. BREATHING BUILDINGS RESERVE THE RIGHT TO CHANGE PRODUCT DESIGN WITHOUT PRIOR NOTIFICATION. Dimensions Electrical H 500 mm Power Rating 0.1 kW D 1,000 mm Voltage 230V AC (+- 10%) W 1,000 mm Full load current 0.5A Weight 80 kg Short Circuit Rating N/A - Control only Physical area 0.5 m 2 Earth Leakage
Breathing Buildings | F Series 31 F500 Dimensioned Drawing PRINTED 12/08/2016 DO NOT SCALE ISOMETRIC IF IN DOUBT, ASK! TOP REVISIONS REV. DESCRIPTION DATE DRAWN A 12/08/ 1 NOTES 2016 CC 14 4X FIXING NEOPRENE BRACKET BRACKETS BONDED TO FRONT FACE OF UNIT NOTES: DAMPER 1. UNIT FINISHED IN GALV. AS CL 950 STANDARD. RAL COLOURS AVAILABLE ON REQUEST AT ADDITIONAL COST. REFER TO QUOTATION / CONTRACT / VARIATION ORDER SCHEDULE B FOR DETAILS FOR COLOUR AND COSTS. 2. GRILLES NOT SHOWN. 3. GRILLES AVAILABLE ON REQUEST AT ADDITIONAL COST. REFER TO QUOTATION ACTUATOR / CONTRACT / VARIATION ORDER SCHEDULE FOR COVER DETAILS FOR COLOUR AND COSTS. CL 950 4. IF UNIT IS POSITIONED LESS THAN 2.7M ABOVE GROUND, 1050 FINGER GUARD GRILLES MUST BE USED. 1050 WIDTH 5. UNIT SUPPLIED WITH 4 NO. FIXING BRACKETS. LENGTH 999 6. TYPE A HANDING SHOWN. 890 TYPE B AVAILABLE (HANDING 95 C 76.5 702 105 DAMPER ALTERS POSITION OF ACTUATOR). B A BREATHING BUILDINGS CONTINUOUSLY WORK TO IMPROVE OUR PRODUCTS. TO ENSURE UP TO DATE DRAWINGS, PLEASE CONTACT BREATHING BUILDINGS DAMPER 275 HEIGHT 400 500 418 MATERIAL: MILD STEEL B A D BACK FINISH SECTION B-B FRONT SECTION A-A GALV. OR ZINTEC POWDER COATED (SHOWN WITHOUT GRILLE) MASS WITHOUT PACKAGING 60KG TOLERANCES EXCEPT WHERE OTHERWISE STATED 890 X X.XX 0.5MM 0.05MM ANGLES 0.5 SURFACE TEXTURE TO BE 1.6 UMRA OR BETTER DE-BURR ALL SHARP EDGES AND HOLES ITEM MUST BE FREE FROM SCRATCHES, DENTS AND INTERNAL CONTROL OTHER BLEMISHES. PANEL DIMENSIONS IN MILLIMETRES E (MAINTENANCE ACCESS THROUGH 890 UNDERSIDE) UNIT 3A, THE SHADE, SOHAM, CB7 5HF T: 01223 450060 F: 01223 450061 www.breathingbuildings.com/products TITLE: SIDE OPEN FOR E-STACK: F500 CLASSIC MIXED AIR DELIVERY VERSION 3 (TYPE A) DRAWING NO: F REVERSE ISOMETRIC 1508_9001 UNDERSIDE REV DRAWN DATE CHK'D DATE 1 CC 12/08/2016 1 2 3 4 5 6 7 SCALE 1:18 A3 SHEET 1 OF 1 CONFIDENTIAL: THIS DOCUMENT IS FOR THE USE OF THE MAIN CONTRACTOR, ARCHITECT, M&E DESIGN CONSULTANT AND M&E SUBCONTRACTOR FOR THE PROJECT NAMED IN THIS DOCUMENT OR ACCOMPANYING CORRESPONDENCE. THE CONTENTS SHOULD NOT BE DISCLOSED TO THIRD PARTIES, INCLUDING OTHER EQUIPMENT SUPPLIERS WITHOUT THE PRIOR CONSENT OF BREATHING BUILDINGS. BREATHING BUILDINGS LTD ©. Performance Installation BREATHING BUILDINGS RESERVE THE RIGHT TO CHANGE PRODUCT DESIGN WITHOUT PRIOR NOTIFICATION. The F Series comes with fixing brackets. U-Value Part L2a requirement 3.5 (W/m2 K) The E-Stack unit can be hung from 4 no. pieces F Series 2.2 (W/m2 K) of M10 (drop-rods). Damper section
32 In a space where mixing is not required we can provide a range of passive ventilation products • Passive Stack Ventilation • Roof Terminals • Dampers • Cross Talk Attenuators • Window Actuation Control
Breathing Buildings | Passive Ventilation 33 Passive Ventilation Breathing Buildings offers a full range of passive ventilation products, either as standalone products or incorporated into a Breathing Buildings system Passive ventilation is an important part of all natural ventilation systems, whether that is providing automated windows in a room, passive acoustic attenuators or high level dampers in an atrium. Breathing Buildings has a comprehensive range of products to suit any natural ventilation scheme either as standalone products or for integrating into a broader Breathing Buildings system. Whatever the requirements you can be sure that we have an appropriate product. Air Flow Strategies Product Information Summer Mode Features When it is warm outside the system operates in upflow • Upward displacement and wind driven ventilation displacement mode, using the stack effect to achieve high • Manual control or Automatic control responding to air flow rates and keep the room at a pleasant temperature. temperature and CO2 • Insulated volume control damper ensures appropriate ventilation rates • Internal temperature sensor with integrated CO2 sensor • Install internal unit from roof or from the room Options • Range of sizes from 600mm square up to 1500mm square • Penthouse louvre or mushroom terminal • Integrated noise attenuation unit offering 25dB Winter Mode for noisy sites, more available on request Without low level openings the unit operates in exchange mode providing inflow and outflow through the damper. • Traffic light indicator panel for window opening • Control signal for automated actuation of low level windows or dampers • Modbus link for integration into wider Building Management Systems (BMS) • Eggcrate grilles
34 Passive Ventilation continued Type 1 - PS600 to PS1500 Dimensional Drawing TERMINAL WIDTH G, LENGTH H MUSHROOM ROOF TERMINAL TERMINAL HEIGHT F (BY BREATHING BUILDINGS) DIM I CURB 150 MIN PASSIVE STACK DAMPER C (BY BREATHING BUILDINGS) SHAFT OPENING 10 WIDTH A, LENGTH B OVER CURB 10 WIDTH D, LENGTH E Terminal Unit Type A B C D E F G H I Mass [kg] PSS600 600 600 12.5 890 890 550 1000 1000 145 18 PSS800 800 800 12.5 990 990 650 1100 1100 95 25 PSS1000 1000 1000 12.5 1340 1340 750 1403 1403 170 40 PSS1200 1200 1200 12.5 1500 1500 875 1869 1869 150 150 PSS1500 1500 1500 12.5 1800 1800 875 2169 2169 150 160 PSR-SERIES 1550 900 12.5 1850 1200 945 2080 1600 150 150 Type 2 - PS600 to PS1500 Dimensional Drawing TERMINAL WIDTH G, LENGTH H TERMINAL HEIGHT F MUSHROOM ROOF TERMINAL (BY BREATHING DIM I BUILDINGS) CURB 150 MIN SHAFT DUCTWORK S/O -25MM DUCTWORK SLEEVE S/O -20MM 338 PASSIVE STACK DAMPER C SHAFT OPENING A & B (BY BREATHING OVERCURB D & E BUILDINGS) Terminal Unit Type A B C D E F G H I Mass [kg] PSS600 600 600 12.5 890 890 550 1000 1000 145 18 PSS800 800 800 12.5 990 990 650 1100 1100 95 25 PSS1000 1000 1000 12.5 1340 1340 750 1403 1403 170 40 PSS1200 1200 1200 12.5 1500 1500 875 1869 1869 150 150 PSS1500 1500 1500 12.5 1800 1800 875 2169 2169 150 160 PSR-SERIES 1550 900 12.5 1850 1200 945 2080 1600 150 150
Breathing Buildings | Passive Ventilation 35 Type 3 - PS600 to PS1500 Dimensional Drawing MUSHROOM ROOF TERMINAL (BY BREATHING TERMINAL WIDTH G, LENGTH H BUILDINGS) TERMINAL HEIGHT F DIM I CURB 150 MIN SHAFT OPENING PASSIVE C WIDTH A, LENGTH B STACK DAMPER (BY BBL) Terminal Unit Type A B C D E F G H I Mass [kg] PSS600 600 600 12.5 890 890 550 1000 1000 145 18 PSS800 800 800 12.5 990 990 650 1100 1100 95 25 PSS1000 1000 1000 12.5 1340 1340 750 1403 1403 170 40 PSS1200 1200 1200 12.5 1500 1500 875 1869 1869 150 150 PSS1500 1500 1500 12.5 1800 1800 875 2169 2169 150 160 PSR-SERIES 1550 900 12.5 1850 1200 945 2080 1600 150 150
36 Roof Terminals R Series Terminations Installation Breathing Buildings offer two roof terminations, A weathered builders curb around the perimeter the penthouse louvre or the mushroom. of the roof penetration and shaft to the E-Stack supports the roof termination which is usually a The penthouse louvre is most frequently associated minimum height of 150mm above the finish roof with a natural ventilation system. We offer a double surface. bladed system as standard which offers class A Once in place the roof terminal is fixed to the curb weather performance with a triple bladed system for using suitable fixings. Once installed a bead of sites where better weather performance is required. mastic or similar is laid around the perimeter of the The standard terminal comes in RAL 7035 overcurb. (Light Grey) with corner posts and gabled roof but other options and sizes are available. The mushroom terminal is an unobtrusive alternative to the traditional bladed metal louvre and has better standard noise attenuation properties. The terminal is RAL 7035 (Light Grey) as standard but other colours are available on request. Both terminals offer optional acoustic attenuation. Shaft An insulated shaft is required between the bottom of the roof termination and the R Series indoor unit. Breathing Buildings can provide this, or else it can be constructed by others. A rubber seal is provided on the top of the E-Stack indoor unit to ensure air tightness with the bottom edge of the shaft. Breathing Buildings has no preference as to the material of the shaft. Previous examples have utilised the concrete soffit, plywood, plasterboard, and ductwork. This is sized to fit the damper (1550mm x 900mm). The terminal height is pre-fitted with a divider. The shaft is to be divided into two pathways vertically for separation of inflow and outflow. Usually this is constructed from either plywood, plasterboard or galvanised steel etc. and does not require insulation. Note that the split is not equal, with the larger section above the E-Stack fans in winter. The vertical divider extends from just above the dampers (typ. 25mm above) on top of the E-Stack unit to the underside of the acoustic attenuator or the penthouse louvre roof terminal.
Breathing Buildings | Passive Ventilation 37 Penthouse Louvre Dimensioned Drawing Physical Properties Typical weight 180 kg A Finish standard MILL Finish Finish options Standard RAL H_UPSTAND H_OVERALL H_LOUVRE 20 Lifting points Eyes supplied as standard A Standard attenuation 11 dB Dnew 65 PRE-DRILLED HOLES LIFTING EYE IN LOWER SILL FOR FIXINGS HOLE SIZE 6.8MM 150 Optional attenuation 33 dB Dnew INTEGRAL CL VERTICAL DIVIDER SECTION A-A (BY BREATHING LOWER SILL (OUTSIDE) SCALE 1 : 10 BUILDINGS) Shaft Dimensions OVERCURB 1200 10 1232 FIXING CL CENTRELINE W 1550 mm D 900 mm 1850 10 50 OVERCURB 2 1882 UP-STAND MUST 55 99 LOWER SILL (OUTSIDE) BE LEVEL MIN 150 CURB TYPE H_LOUVRE H_UPSTAND H_OVERALL A 985 1090 1190 Weather Performance B 785 890 990 ROOFING WATERPROOF SINGLE UPSTAND MATERIAL SCREW TYPE PLY MEMBRANE, TYP. WEATHER LIP, TYP. CONCRETE M6 STAINLESS STEEL RESIN SARNAFIL G410 OR 12MM MARINE ANCHOR SIMILAR BONDED TO DETAIL A PLYWOOD OR TIMBER STEEL M6 STAINLESS STEEL BOLT OR 5MM SCREW 5MM STAINLESS STEEL SELF UP-STAND (BY OTHERS) SCALE 1 : 5 SIMILAR FIXED TO INNER SHAFT (BY OTHERS) Double blade Triple blade TAPPING SCREW MASONRY NOT RECOMMENDED Performance Class A up to 1 m/s Class A up to 2 m/s airflow face velocity airflow face velocity Test involves simulated rainfall of 75l/h at a wind speed of 13m/s (29 mph). Full BSRIA weather performance test data available on request Mushroom Terminal PLAN VIEW Physical Properties TYPICAL LIFTING METHOD Height (Inc. base) 945 mm Curb dimensions 1850 (l) x 1200 (w) x 150 (h) 1600 A A Typical weight 150 kg BIRD MESH Finish standard RAL 7035 2080 INTEGRAL VERTICAL DIVIDER Finish options Standard RAL INTEGRAL GRP VERTICAL SECTION A-A SECTION B-B 60/40 DIVIDER B Standard attenuation 17 dB Dnew Optional attenuation 21 - 28 dB Dnew 945 A 2 UPSTAND MUST B BE LEVEL 106 150 MIN 1550 10 S/O 900 10 S/O FIXING CENTRELINE Shaft Dimensions +10 +10 1850 - 5 OVERCURB 1200 - 5 OVERCURB 150 ROOFING WATERPROOF SINGLE PLY W 1550 mm UP-STAND MATERIAL FIXING SHAFT WALL DETAIL A MEMBRANE, TYP. D 900 mm M6 STAINLESS STEEL RESIN SCALE 1 : 5 SARNAFIL G410 OR CONCRETE SIMILAR BONDED TO ANCHOR UP STAND (BY TIMBER STAINLESS STEEL M6 BOLT OR 5MM OTHERS) DIA SCREW STEEL 5MM DIA STAINLESS STEEL SELF- TAPPING SCREW MASONRY NOT RECOMMENDED Weather Performance Water testing has been carried out at the BRE using test method prEN 15601—Hygrothermal performance of buildings—resistance to wind driven rain coverings with discontinuously laid small elements. The terminal was subject to 75mm/hr/m2 at a wind speed of 30mph (13.4 m/s). Water ingress during the tests was too small to measure in meaningful terms. Terminal has also been tested under storm conditions at BRE with 60 mph wind.
38 Roof Terminals S Series Terminations An insulated shaft is required between the bottom of the roof termination and the S Series indoor unit. Breathing Buildings can provide this, or else it can be constructed by others. The penthouse louvre units are offered in both double and triple blade arrangements and we now have mushroom terminations available across the product range. Shaft Installation An insulated shaft needs to be constructed by others A weathered builders curb around the perimeter between the bottom of the roof termination and the of the roof penetration and shaft to the E-Stack S series. A rubber seal is provided on the top of supports the roof termination which is usually a the e-stack to ensure air tightness with the bottom minimum height of 150mm above the finished roof edge of the shaft wall. Breathing Buildings has no surface. Once in place the roof terminal is fixed to the preference as to the material of the shaft. Previous curb using suitable fixings. Once installed a bead of examples have utilised the concrete soffit, marine mastic or similar is laid around the perimeter of the plywood, plasterboard, and ductwork. This is sized overcurb. to fit the damper (1500mm x 1500mm or 1200mm x 1200mm). An L divider is required in the shaft (by others or by Breathing Buildings). The L divider is located to form a smaller square section in the corner of the square shaft, thereby creating an L shape division. The L divider is orientated so that it matches similar dividers in the mushroom or penthouse termination and the S series unit. The shaft divider commences just above the top of the S series unit (typically 25mm above) and extends up through the shaft to mid-way to the curb level (just underneath the roof terminal).
Breathing Buildings | Passive Ventilation 39 S1500 Penthouse Louvre Dimensioned Drawing CROSS SECTION VIEW OVERALL HEIGHT LOUVRE HEIGHT ≈ 1150 ≈ 1250 985 20 PRE-DRILLED HOLES IN LOWER SILL FOR LIFTING EYES A FASTENERS HOLE SIZE 6.8MM ROOF WATERPROOF SINGLE PLY. MEMBRANE TYP. SARNAFIL G410 OR SIMILAR, BONDED TO UP-STAND INTEGRAL (BY OTHERS) "L" DIVIDER 1800 10 OVERCURB FASTENER 1832 CENTRELINE LOWER SILL (OUTSIDE) 50 55 UPSTAND MATERIAL FASTENER TYPE MIN CURB 99 CONCRETE M6 STAINLESS STEEL RESIN CURB 150 ANCHOR TIMBER M6 STAINLESS STEEL BOLT OR 5MM DIA SCREW 50MM WEATHER LIP, STEEL 5MM DIA STAINLESS STEEL SELF- TYP. 12MM MARINE TAPPING SCREW PLYWOOD OR SIMILAR, MASONARY NOT RECOMMENDED FIXED TO INNER SHAFT (BY OTHERS) Physical Properties Shaft Dimensions Typical weight 220 kg W 1,500 mm Finish standard MILL Finish D 1,500 mm Finish options Standard RAL Lifting points Eyes supplied as standard Weather Performance Standard attenuation 11 dB Dnew Double blade Triple blade Optional attenuation 33 dB Dnew Performance Class A and 99.9% Class A and 99.9% rejection at face rejection at face velocity up to 0.5 m/s velocity up to 2 m/s Test involves simulated rainfall of 75l/h at a wind speed of 13m/s (29 mph). Full BSRIA weather performance test data available on request
You can also read