Application Process for the Licensing of Restaurants, Bars and Nightclubs Contents Foreword............................................................................................................. 4 Introduction to procedures................................................................................. 5 1. Preliminary stage............................................................................................................ 6 1.1 Classification of similar establishments................................................................. 6 1.2 Requirements for similar establishments................................................................ 6 1.2.1 Restaurants................................................................................................... 6 1.2.1.1 Specific requirements for premier restaurants................................ 6 1.2.1.2 Specific requirements for first-class restaurants............................. 8 1.2.1.3 Specific requirements for second-class restaurants........................ 10 1.2.2 Nightclubs................................................................................................... 11 1.2.2.1 Specific requirements for premier nightclubs................................ 11 1.2.2.2 Specific requirements for first-class nightclubs............................. 12 1.2.3 Bars............................................................................................................... 14 1.2.3.1 Specific requirements for premier bars........................................... 14 1.2.3.2 Specific requirements for first-class bars........................................ 14 1.3 Requirements for site selection............................................................................... 15 1.4 Plans and specifications of documents to be submitted.......................................... 16 1.4.1 Project alterations....................................................................................... 16 1.4.2 Water supply plan........................................................................................ 17 1.4.3 Plans for drainage and sewage disposal, grease interceptor and structure....................................................................................................... 17 1.4.4 Structural plan............................................................................................. 18 1.4.5 Circuit plan for fuse box of power equipment............................................ 18 1.4.6 Fire-fighting equipment plan and fire-fighting system design plan............. 18 1.4.7 Requirements for documents to be submitted concerning alteration to project plans…………………………….................................................... 18 1.4.8 Requirements for documents to be submitted concerning structural alterations..................................................................................................... 19 1.4.9 Fuel facilities............................................................................................... 19 1.4.10 Sound Insulation devices............................................................................. 21 1
Application Process for the Licensing of Restaurants, Bars and Nightclubs 1.5 Various projects and requirements for relevant devices ......................................... 21 1.5.1 Architectural design..................................................................................... 21 1.5.2 General requirements................................................................................... 22 1.5.3 Kitchens........................................................................................................ 24 1.5.4 Sanitary devices........................................................................................... 25 1.5.5 Refrigerators................................................................................................. 26 1.5.6 Food lifts...................................................................................................... 26 1.5.7 Lighting and ventilation systems................................................................. 27 1.5.8 Grease interceptor......................................................................................... 27 1.5.9 Ventilator...................................................................................................... 27 1.5.10 Fuel facilities................................................................................................ 27 1.5.11 Soot filter and aroma elimination system..................................................... 27 1.5.12 Sewage disposal system............................................................................... 28 1.5.13 Drainage system........................................................................................... 28 1.5.14 Water supply system……............................................................................. 28 1.5.15 Noise prevention measures.......................................................................... 28 1.5.16 Pest control.................................................................................................. 29 1.5.17 Guidelines for analysis of fire-fighting safety.............................................. 29 1. Requirements for restaurants and nightclubs, with guidelines for 29 analysis of fire-fighting safety……..…….………………………........ 1.1 Layout, ceiling, decorations and floor.......................................... 29 1.2 Fire-fighting equipment................................................................ 30 1.3 Power equipment…...................................................................... 31 1.4 Fuel facilities................................................................................. 31 2. Requirements for bars and guidelines for fire-fighting……….…….... 32 2.1 Layout, ceiling, decorations and floor…...................................... 32 2.2 Fire-fighting equipment................................................................ 32 2.3 Power equipment.......................................................................... 34 1.5.18 Guidelines to minimize environmental impact.......…………..................... 34 1. General guidelines for controlling noise................................................ 35 2. Special guidelines for controlling noise................................................. 35 3. Guidelines for controlling soot and odours............................................ 36 2
Application Process for the Licensing of Restaurants, Bars and Nightclubs 4. Guidelines for controlling sewage......................................................... 37 2. Application........................................................................................................................ 38 2.1 Procedure and charges of license application for similar establishments.................. 38 2.1.1 Documents required for establishments in buildings under construction.... 39 2.1.2 Documents required for establishments in completed buildings................. 40 2.2 Renewal of Licence.................................................................................................. 42 3. Construction...................................................................................................................... 43 44 4. Examination...................................................................................................................... Appendix 1: Table I - minimum area for kitchens................................................................... 46 Table II – number of sanitary devices….………………………........................ 47 Appendix 2: Buildings and locations of commemorative and artistic value……………..…. 49 Appendix 3: Relevant laws and regulations………………………….................................... 54 3
Application Process for the Licensing of Restaurants, Bars and Nightclubs Foreword An increasing number of investors are setting up restaurants, bars and nightclubs (hereinafter termed similar establishments) in the Macau SAR. The opening of similar establishments is regulated by relevant laws and regulations. In order to enable applicants to clearly understand such legal requirements, and to accelerate the licensing process, the Macau Government Tourist Office (MGTO) has formulated an ‘Application Process for the licensing of Restaurants, Bars and Nightclubs’. This guide is based on the laws and decrees which regulate buildings, projects, fire-fighting, sanitary devices, environmental impact including noise. It is divided into four stages: preparation, application, construction and examination, and elaborates on requirements including classification of similar establishments, specific requirements for different classes, site selection, design and specifications of documents. The contents for relevant laws and regulations are in this guide for those who require more in-depth information. Suggestions or questions related to this guide are welcome and may be sent to MGTO via telephone, fax, letter, e-mail or personal visit to MGTO’s offices in Alameda Dr. Carlos d' Assumpção, 335-341, Edificio Centro Hotline, 12th floor, Macau. Your valued opinions and queries will help improve the licensing procedure. *E-mail:dl@macautourism.gov.mo *Telephone number :83971312; 83971313 *Fax number:28330518 Note: This manual provides basic information for an application for restaurants, bars or nightclubs. Nonetheless, establishment’s design should comply with the relevant laws and clause of regulations, especially if the proposed establishment of a restaurant, nightclub or bar is located in the hotel premises, its requirement for the application must be in compliance with the regulations of law. For more details, please refer to Decree-Law 16/96/M dated 1st April and Portaria 83/96/M dated 1st April. In case of discrepancies between English, Portuguese and Chinese versions of contents in this manual, the Chinese version shall prevail. 4
Application Process for the Licensing of Restaurants, Bars and Nightclubs Introduction to Procedures According to the first item of Article 2 of Decree-Law 16/96/M on 1st April, licences of the first, second and third groups of establishments (restaurants, bars and nightclubs) indicated in Article 6 of the Decree-Law, are issued by the Macao Government Tourist Office. Investors may enquire about the application process and request relevant guides from the Macau Government Tourist Office by phone, e-mail, and fax, or visit MGTO at the service desk in person to enquire about documentation, procedures and taxes for licensing restaurants, bars and nightclubs. Applicants should submit an application form, relevant documents and plans. Design plans must be made by architects, civil engineers or technicians, electronic or mechanical engineers or technicians, fire-fighting engineering companies, building contractors or construction companies recognized by Lands, Public Works and Transport Bureau (DSSOPT). All theses plans require the signatures of the applicants and relevant technicians. If the application meets statutory requirements and has been approved by the Macau Government Tourist Office, then construction work can be started per the approved plans. At this time, construction licences must be submitted. Information for the application of construction licences is available at DSSOPT. If alterations are contemplated in the approved project plans in the course of decoration and reconstruction, applicants must apply to MGTO for approval. After consulting the ideas on technical issues from relevant departments, the MGTO will decide whether to approve the alteration. The applicants should apply to have equipment examined six or eighteen months (in case of the establishments in hotels under construction) from the date of receiving the notice of licence application by MGTO, otherwise the relevant permission will cease to be effective. If the examining committee finds that the project is completely in line with the approved plans and the advice from all the participating departments, and that equipment and installation conforms to statutory standards, MGTO will grant a licence within fifteen days from the date of spot examination. If a project fails examination, applicants must rectify deficiencies within the stated period, followed by a re-examination conducted by the examining committee for verification. Upon approval, MGTO will grant a licence to applicants within fifteen days of the date of examination. Similar establishments cannot commence operations until they receive a licence and complete registration for Starting Operations in the Finance Services Bureau (DFS). 5
Application Process for the Licensing of Restaurants, Bars and Nightclubs 1. Preliminary Stage If investors can clearly understand and comply with the relevant regulations for site selection, environment, fire-fighting and hygienic safety, they are likely to obtain licences more quickly within the statutory period. All requirements will be elaborated upon in the relevant chapters. If you have questions, please feel free to make enquiries at the Licensing & Inspection Department of the Macau Government Tourist Office. 1.1 Classification of similar establishments According to Article 6 in Decree-Law 16/96/M dated 1st April, similar establishments are classified as follows: First group: Premier, first-class and second-class restaurants; Second group: Premier and first-class nightclubs; Third group: Premier and first-class bars; Fourth group: Drinking establishments; Fifth group: Food and beverage establishments MGTO will be responsible for the issue of licences and the monitoring of similar establishments in the first, second and third groups. 1.2 Requirements for similar establishments 1.2.1 Restaurants 1.2.1.1 Special requirements for premier restaurants 1. General requirements: - Customer area must be separated from operation area; - Toilets must be separated according to gender; - If neither food nor drinks are prepared on the same floor as the customer area, restaurants must be equipped with operational staircase or dumb waiters; - Kitchens and pantries, segregated or not, with suitable size and area; - The restaurant must be equipped with refrigeration facilities for the preservation and freezing of food and beverages, and cater to a specific number of customers and the characteristics of food and beverages 6
Application Process for the Licensing of Restaurants, Bars and Nightclubs served; - The restaurant must be equipped with toilet facilities reserved exclusively for staff. 2. Restaurants located in commercial buildings where toilets are available at the same floor, there is no need to be equipped with toilet facilities, yet toilet facilities in such commercial buildings must conform to the basic requirements listed in Table II of Appendix 1; these toilet facilities must be located on the same floor as the restaurants and are for customers and staff of the restaurants only. 3. Kitchens in self-service, fast food or Japanese restaurants need not be separated from the customers, and can face the dining area. 4. Restaurants providing Chinese and Korean hotpots are permitted to prepare food on diners’ tables if proper fire-fighting safety equipment is at hand. 5. Restaurants must provide an entrance for customers independent of the staff/service entrance. 6. Premier restaurants with a customer capacity of 200 or more must install washrooms for the handicapped. 7. Areas designated for customers in restaurants must: - Install a cloakroom near the entrance; - Equip the parlour with a bar; - Determine customer capacity of the restaurant according to the area of the restaurant to enable customers to have enough personal space and enjoy efficient service; - Provide smoking and non-smoking areas; - Equip bathrooms with quality-finish materials and facilities, washtubs with hot and cold water, and washrooms for the handicapped. 8. Only restaurants providing Oriental food are not required to equip parlours with bars. 9. Restaurant operation areas should: 7
Application Process for the Licensing of Restaurants, Bars and Nightclubs - Provide an entrance; - Install a kitchen with efficient, modernized, purpose-made mechanical devices; - Install a pantry comprising two areas for storing soiled and clean cutlery. The kitchen must not be located in the passageway between the restaurant and the pantry. The pantry must be located between the kitchen and the customer area; - Reserve space for the storage of food, beverages and empty bottles according to the capacity and characteristics of the restaurant; - Provide dressing rooms for staff. 10. Restaurants must provide an elegant environment and high-class service to customers via quality decorations and facilities. 11. Non-Oriental restaurants must provide menus for Portuguese food, Macanese food and food from other countries plus a wine list with. Each bar of the restaurant must have a “sommelier”. 12. Cookware and cutlery are the responsibility of a qualified chef. 13. Restaurants are required to recruit staff who have a fair knowledge of the Portuguese, Chinese and English languages. 14. The largest capacity of the restaurant is to be determined according to the area used by customers. The minimum parameter is 2m2 per person. 1.2.1.2 Special requirements for first-class restaurants 1. General Requirements - Customer area must be separated from operation area; - Toilets must be separated according to gender; - If neither food nor drinks are prepared on the same floor as the customer area, restaurants must be equipped with operational staircase or dumb waiters; - Kitchens and pantries, segregated or not, with suitable size and area; - Restaurants must be equipped with refrigeration facilities for the preservation and freezing of food and beverages, and cater to a specific number of customers and the characteristics of food and beverages served; 8
Application Process for the Licensing of Restaurants, Bars and Nightclubs - Restaurants must be equipped with toilet facilities reserved exclusively for staff. 2. Restaurants located in commercial buildings where toilets are available at the same floor, there is no need to be equipped with toilet facilities, yet toilet facilities in such commercial buildings must conform to the basic requirements listed in Table II of Appendix 1; these toilet facilities must be located on the same floor as the restaurants and are for customers and staff of the restaurants only. 3. Kitchens in self-service, fast-food or Japanese restaurants need not be separated from the customers, and can face the dining area. 4. Restaurants providing Chinese and Korean hotpots are permitted to prepare food on diners’ tables if proper fire-fighting safety equipment is at hand. 5. Restaurants must provide an entrance for customers independent of the staff/service entrance. 6. Areas designated for customers in restaurants must: - Install a cloakroom near the entrance; - Equip the parlour with a bar; - Determine customer capacity of the restaurant according to the area of the restaurant to enable customers to have enough personal space and enjoy efficient service; - Provide smoking and non-smoking areas; - Equip bathrooms with quality-finish materials and facilities, washtubs with hot and cold water, and washrooms for the handicapped. 7. Only restaurants providing Oriental food are not required to equip parlours with bars. 8. Non-Oriental restaurants must provide menus for Portuguese food, Macanese food and food from other countries plus a wine list with. 9. Cookware and cutlery are the responsibility for a qualified chef. 9
Application Process for the Licensing of Restaurants, Bars and Nightclubs 10. Restaurants must provide decorations and facilities of fair quality. The largest capacity of the restaurant is to be determined according to the area used by customers. The minimum parameter is 1.5m2 per capita. 1.2.1.3 Special requirements for second-class restaurants 1. General Requirements: - Customer area must be separated from operation area; - Toilets must be separated according to gender; - If neither food nor drinks are prepared on the same floor as the customer area, restaurants must be equipped with operational staircase or dumb waiters; - Kitchens and pantries, segregated or not, with suitable size and area; - Restaurants must be equipped with refrigeration facilities for the preservation and freezing of food and beverages, and cater to a specific number of customers and the characteristics of food and beverages served; - The restaurant must be equipped with toilet facilities reserved exclusively for staff. 2. Restaurants located in commercial buildings where toilets are available at the same floor, there is no need to be equipped with toilet facilities, yet toilet facilities in such commercial buildings must conform to the basic requirements listed in Table II of Appendix 1; these toilet facilities must be located on the same floor as the restaurants and are for customers and staff of the restaurants only. 3. Kitchens in self-service, fast food or Japanese restaurants need not be separated from the customers, and can face the dining area. 4. Restaurants providing Chinese and Korean hotpots are permitted to prepare food on diners’ tables if proper fire-fighting safety equipment is at hand. 5. Second-class restaurants should also comply with the following general requirements: - Cloakroom must be installed near entrance; - Space must be reserved for the storage of food, beverages and empty bottles. 10
Application Process for the Licensing of Restaurants, Bars and Nightclubs 6. Restaurants must be equipped with a certain quantity and acceptable quality of facilities. 7. The largest capacity of the restaurant is to be determined according to the area used by customers. The minimum parameter is 1m2 per capita. 8. If restaurants do not provide an entrance for customers independent from the staff/service entrance, the reception of goods in the restaurant must be undertaken during the non-business hours. 1.2.2 Nightclubs 1.2.2.1 Specific requirements for premier nightclubs 1. General requirements: - Customer area must be separated from operation area; - Toilets must be separated according to gender; - If neither food nor drinks are prepared on the same floor as the customer area, restaurant area of nightclub must be equipped with operational staircase or dumb waiters; - Kitchens and pantries, segregated or not, with suitable size and area; - Nightclubs must be equipped with refrigeration facilities for the preservation and freezing of food and beverages, and cater to a specific number of customers and the characteristics of food and beverages served; - Nightclubs must be equipped with toilet facilities reserved exclusively for staff. 2. Nightclubs located in commercial buildings where toilets are available at the same floor, there is no need to be equipped with toilet facilities, yet toilet facilities in such commercial buildings must conform to the basic requirements listed in Table II of Appendix 1; these toilet facilities must be located on the same floor as the nightclubs and are for customers and staff of the nightclubs only. 3. Nightclubs may be installed only in buildings designated partly for residential purposes. 11
Application Process for the Licensing of Restaurants, Bars and Nightclubs 4. For calculating the capacity of customers, the minimum parameter for the nightclub is 1m2 per capita, excluding space allocated for bands and Disc Jockey. 5. In addition to general requirements, nightclubs must also: - Install an entrance composed of low visibility materials; - Provide an entrance for customers independent from the staff/service entrance; - Install a lobby; - Install a cloakroom near the entrance; - Provide a dance floor; - Install a kitchen and pantry catering to the operation; - Install dressing rooms or space exclusively for staff and performers respectively; - Reserve space for the storage of food, beverages and empty bottles. 6. Construction materials must be assured an acceptable level of noise prevention. 7. If the nightclub provides drinks only, the counter may be used as a kitchen and for storage of cutlery. Exclusive areas for kitchen and pantry are not necessary. 8. Premier nightclubs should: - Provide elegant decorations, facilities, furniture, environment and service; - Equip bathrooms with hot and cold water, quality-finish materials and facilities. 1.2.2.2 Specific requirements for first-class nightclubs 1. General requirements: - Customer area must be separated from operation area; - Toilets must be separated according to gender; - If neither food nor drinks are prepared on the same floor as the customer area, restaurants must be equipped with operational staircase or dumb waiters; - Kitchens and pantries, segregated or not, with suitable size and area; - The nightclub must be equipped with refrigeration facilities for the 12
Application Process for the Licensing of Restaurants, Bars and Nightclubs preservation and freezing of food and beverages, and cater to a specific number of customers and characteristics of the food and drinks; - The nightclub must be equipped with toilet facilities reserved exclusively for staff. 2. Nightclubs located in commercial buildings where toilets are available at the same floor, there is no need to be equipped with toilet facilities, yet toilet facilities in such commercial buildings must conform to the basic requirements listed in Table II of Appendix 1; these toilet facilities must be located on the same floor as the nightclubs and are for customers and staff of the nightclubs only. 3. Nightclubs may only be installed in buildings partly designated for residential purposes. 4. For calculating the capacity of customers, the minimum parameter for the nightclub is 1m2 per capita, excluding space reserved for bands and Disc Jockey. 5. In addition to general requirements, nightclubs must also: - Install an entrance made of low visibility materials; - Provide an entrance for customers independent from the staff/service entrance; - Install a lobby; - Install a cloakroom near the entrance; - Install a dance floor; - Install a kitchen and pantry which caters to the operation; - Install dressing rooms or space exclusively for staff and performers respectively; - Reserve space for the storage of food, beverages and empty bottles. 6. Construction materials must be assured an acceptable level of noise prevention. 7. If the nightclub provides drinks only, the counter may be used as a kitchen and for storage of cutlery. Exclusive areas for kitchen and pantry are not necessary. 13
Application Process for the Licensing of Restaurants, Bars and Nightclubs 1.2.3 Bar 1.2.3.1 Specific requirements for premier bars 1. General requirements: - Customer area must be separated from operation area; - Toilets must be separated according to gender; - If neither the food nor beverages are prepared on the same floor as the customer area, bar must be equipped with operational staircase or dumb waiters; - Kitchens and pantries, segregated or not, with suitable size and area; - Bar must be equipped with refrigeration facilities for the preservation and freezing of food and beverages, and cater to a specific number of customers and the characteristics of food and beverages served; - Bar must be equipped with toilet facilities reserved exclusively for staff. 2. Bars located in commercial buildings where toilets are available at the same floor, there is no need to be equipped with toilet facilities, yet toilet facilities in such commercial buildings must conform to the basic requirements listed in Table II of Appendix 1; these toilet facilities must be located on the same floor as the bar and are for customers and staff of the bars only. 3. In addition to general requirements, bars must: - Install an entrance made of low visibility materials; - Provide an entrance for customers independent of the staff/service entrance; - Install a cloakroom near the entrance; - Reserve space for the storage of food, beverages and empty bottles. 4. Bars must have a kitchen-pantry installed, which must be located within the counter area. 5. For calculating the capacity of customers, the minimum parameter for the bar is 1m2 per person. 6. Premier bars must be equipped with dressing rooms or spaces reserved exclusively for staff and project an elegant environment with decorations and facilities to provide service of superior quality. 1.2.3.2 Specific requirements for first-class bars 1. General requirements: - Customer area must be separated from operation area; 14
Application Process for the Licensing of Restaurants, Bars and Nightclubs - Toilets must be separated according to gender; - If neither the food nor beverages are prepared on the same floor as the customer area the bars must be equipped with operational staircase or dumb waiters; - Kitchens and pantries, segregated or not, with suitable size and area; - Bar must be equipped with refrigeration facilities for the preservation and freezing of food and beverages, and cater to a specific number of customers and the characteristics of food and beverages served; - Bars must be equipped with toilet facilities reserved exclusively for staff. 2. Bars located in commercial buildings where toilets are available at the same floor, there is no need to be equipped with toilet facilities, yet toilet facilities in such commercial buildings must conform to the basic requirements listed in Table II of Appendix 1; these toilet facilities must be located on the same floor as the bar and are for customers and staff of the bars only. 3. In addition to general requirements, bars must: - Install an entrance made of low visibility materials; - Install an entrance for customers independent of the staff/service entrance; - Install a cloakroom near the entrance; - Reserve space for the storage of food, beverages and empty bottles. 4. Bars must be equipped with a kitchen-pantry located within the counter area. 5. For calculating the capacity of customers, the minimum parameter for the bar is 1m2 per person. 1.3 Requirements for site selection 1. Site for establishment can be in a fully-constructed building or building which under construction; 2. Establishment must hold a utility licence granted by the Lands, Public Works and Transport Department (DSSOPT); 3. Establishment cannot legally proceed to renovation without approval from the proprietor; 4. Establishment must be equipped with electricity supply; 15
Application Process for the Licensing of Restaurants, Bars and Nightclubs 5. Establishment must be equipped with water supply and sewage disposal drainage; 6. Establishment must be equipped with sufficient fire escapes; 7. Establishment must not be used for residential purposes, even temporarily; 8. Establishment must be far from places where animals are raised and where environmental hygiene may be affected; 9. The Cultural Affairs Bureau (IC) must be consulted if the establishment is to be set up in a historical site; 10. If a restaurant employs over 30 members of staff the opinion of the Labour Affairs Bureau must be sought on safety and hygiene conditions of working environment. 1.4 Plans and specifications of documents to be submitted Design plans must be made by architects, civil engineers or technicians, electronic or mechanical engineers or technicians, fire-fighting engineering companies, building contractors or construction companies recognised by Lands, Public Works and Transport Department (DSSOPT). All plans require the signatures of applicants and relevant technicians. The objective is to ensure that the applicant is obliged to carry out any alterations made in the establishment and enables related departments to analyze whether the layout, fit-out and facilities conform to relevant laws and regulations. 1.4.1 Project alterations 1. Location plans at a scale of 1:1000; 2. Construction floor plans, elevations and sectional plans at a scale of 1:100 should include: - Approved plans; - Combination plans (red denotes alteration and yellow denotes cancellation); - Altered plans. At a minimum, the aforementioned design plan should include the following information: - Places for cooking, preparing and dealing with food; - Areas for customers; 16
Application Process for the Licensing of Restaurants, Bars and Nightclubs - Bathrooms; - Storerooms; - Cloakrooms for customers; - Layout of dining tables and facilities (e.g.) seats, TV, counter, storage cabinet and stove; - All entrances, exits and interior passageways; - All windows, air-extraction /smoke-extraction /ventilation shaft, smoke emission flue or electronic ventilation flue and air-conditioning facilities; - Ceiling and staircase height in establishments, and the use and area of fit-out. In accordance with the special requirements for different establishments, the aforementioned blueprint should include the following information: - Bathrooms for handicapped; - Parlour equipped with bar; - Smoking areas and non-smoking area; - Entrance for customers; - Entrance for operations; - Dressing rooms for staff; - Bathroom for staff; - Operation areas; - Pantry. 1.4.2 Water supply plan Floor plan of water supply at a scale of 1:100. (Should indicate clearly the pipe calibre of water supply facilities). 1.4.3 Plans for drainage and sewage disposal, grease interceptor and structure 1. Floor plan of drainage and sewage disposal at a scale of 1:100; 2. Shop drawing of grease interceptor: Top view plans, floor plans and sectional plans; 17
Application Process for the Licensing of Restaurants, Bars and Nightclubs 3. Building structure and foundation plan at a scale of 1:100; 4. Basement floor plan of establishments at a scale of 1:100 (if establishments contain basements). The aforementioned design must include following information: - Clearly indicate clean water and sewage system; sewage collection and joint conditions of grease interceptor; - Flow direction of groundwater and water channel, input and output of grease interceptor and design and standard height of sand drain within building. 1.4.4 Structural plan 1. Floor plans at a scale of 1:100; 2. Sectional plans at a scale of 1:10 or 1:20. 1.4.5 Circuit plan for fuse box of power equipment 1.4.6 Fire-fighting equipment plan and fire-fighting system design 1. Floor plan of fire-fighting equipment at a scale of 1:100– must clearly show location of relevant installation (e.g. fire distinguisher, exit instructions, automatic emergency lights, etc.); 2. If establishments are installed with fire-fighting system, a design plan of the fire-fighting system at a scale of 1:100 must be submitted in accordance with regulations that different colours be used to indicate pipes of different diameter. Design of fire-fighting equipment and fire-fighting system can be shown in same plan. 1.4.7 Requirements for documents to be submitted concerning alteration to project plans 1. With regard to alteration in construction documentation should briefly include contents of construction items, including altered fit-out and 18
Application Process for the Licensing of Restaurants, Bars and Nightclubs uses, plans for water supply and drainage, fire-fighting equipment, and other facilities and adopted construction materials; 2. Responsibility statement from construction plan technician, who must be an architect, civil engineer or civil engineering technician registered with DSSOPT; 3. Applicants and designers must sign aforementioned design exposition documents; 4. If neighbouring apartments dismantle/construct additional common walls or floor slabs, owners must sign an agreement statement. 1.4.8 Requirements for documents to be submitted concerning structural alteration If establishment is to undergo structural alteration, structural proposals must be attached with documents of structural plans, calculation sheets and responsibility statement of structural plan technicians of proposed design. 1.4.9 Fuel facilities The storage of liquid petroleum gas exceeding a volume of 53dm3 is subject to compulsory regulation. Storage equipment and gas transportation must conform to administrative regulation 28/2002 “Safety regulations of storage facilities of individual liquefied petroleum gas containers with volume not exceeding 200m3" and administrative regulation 30/2002 “Technical regulations of fuel piping supply facilities in the building". Applicants must submit plans and relevant information to the DSSOPT for approval. Moreover, if each division of the kitchen or cooking area uses heating apparatus of fuel unit power and total power of over 35kw and 50kw respectively, fuel facilities of relevant gas supply equipment should conform to technical conditions stipulated by administrative regulation 26/2002 “Safety regulations of high-power fuel equipment installation" and undergo relevant application and approval procedures. In additional, applicants must abide by the decision of the Fire Service Department. In accordance with aforementioned approval of relevant administrative regulations, general plans and relevant information requested are summarized below (if not listed below, it shall depend on the need of supplementary in installation approval): 19
Application Process for the Licensing of Restaurants, Bars and Nightclubs 1. Storage facilities for liquefied petroleum gas and equipment: - Storage facility’s location, environment, floor layout, construction materials and ventilation, ancillary equipment installation, pipe location, layout, system diagrams, signs and illustrations; - Liquefied petroleum gas storage container, specifications, installation condition, individual and total volume in kilograms or litres and its location, layout and corresponding indications, signs and illustrations; - Information and illustration of electrical devices and explosion -proof equipment; - Fire-fighting system installation information and corresponding indications, signs and illustrations. Petroleum gas vaporization facilities, parts of facilities (this column is only suitable for partition of storage section; if they are not separated, it will be considered per column above): - Vaporization facilities’ location and environment, floor layout, construction materials, ventilation, vaporization facilities and model, specifications, individual and total vaporization capability, installation and conditions, pipe system diagram and equipment location and corresponding relevant indications, signs and illustrations; - Information and illustration of electrical devices and explosion -proof equipment ; - Fire-fighting system installation information, relevant indications, signs and illustrations. 2. Fuel gas transport system and pipe section (from gas supply facilities to fuel gas area): - Fuel gas transport and pipe system, equipped facilities' floor distribution plans and relevant information, indications, signs and illustrations; - Pipe material and other fittings information and illustration in accordance with regulation or equivalent standard; - Protection measures, information and relevant indications and illustration of piping in building, ceiling and outdoor areas; 20
Application Process for the Licensing of Restaurants, Bars and Nightclubs - Site information and relevant illustration of fuel gas piping and other piping, electrical wire, electrical cable, switch panel and electrical points. 3. Kitchen and fuel gas stoves, heating apparatus : - Kitchen location, floor layout and fit-out details, relevant construction details and piping material illustration, ventilation, fuel gas piping system diagram and equipment layout, fire apparatus or heating apparatus’s individual and total power, automatic safety gear and equipment installation, site space, electrical devices and facilities protection standard and space between fuel gas apparatus and relevant indications, signs and illustrations; - Fire-fighting system installation information and relevant indications, signs and illustrations. 1.4.10 Sound insulation devices Relevant design must consider existing special regulations, especially rules for city construction, fire fighting and safety. The submitted design should include design details, design plans, relevant technical indicators and specifications of sound insulation capability and manual, and quantity of musical devices planned with technical parameters and manual. 1.5 Various projects and requirements for relevant devices Standards of safety facilities and installations such as structure, fire-fighting and environmental hygiene in establishments is regulated by current law and monitored by relevant departments. 1.5.1 Architectural design 1. If establishment caters to 50 or less people, width of exit should not be less than 0.90m. 2. If establishment caters to over 50 people but less than 100, at least two exits must be available. Width of individual exit must not be less than 1.10m while total width of exits must not be less than 2.30m. 3. If establishment caters to more than 100 people but less than 200, width of 21
Application Process for the Licensing of Restaurants, Bars and Nightclubs exit must not be less than 1.20m while total width of exit must not be less than 2.50m. 4. If establishment caters less than 50 people, the width of the passageways should not be less than 1.00m. Or if establishment caters more than 50 people, the width of the passageways should not be less than 1.10m. 5. Exit door must open outward, and must not occupy pavement area (public roads or public pavements). 6. If the aforementioned location does not have alternative evacuation exits in the establishment, distance between establishment and exit door must not exceed 30m. If there is choice of evacuation exit, distance must not exceed 45m (only suitable for ground floor or ground floor and loft or basement with flat); if the exit route is complicated, an appropriate proportion exit diagram must be attached. 7. Exterior projections, such as signage, gas exhaust flue or air conditioning, must not exceed 0.5m and 0.75m, and space between them and pavements should not be less than 2.70m and 3.50m (Exterior projections of building generally not permitted in NAPE area). 8. If establishment staircase cannot adopt shape of a fan its width should not be less than 1.0m. If staircase only goes to store room or area where no one works, it may be exempt from regulations. 9. Width of staircase step should not be less than 0.23m and the height should not exceed 0.18m. 10. Clear height of staircase for people should not be less than 2.20m. 11. Clear height of kitchens should not be less than 2.20m. 12. Except for washrooms and corridors, areas for customers’ use should not measure less than 2.60m high. In a five-star or four-star hotel, the height should be at least 3.50m. In a three-star or two-star hotel, the height should be at least 3.00m. 13. Kitchens must be provided with one-hour fire resistance (CRF60) materials 22
Application Process for the Licensing of Restaurants, Bars and Nightclubs and be of floor-slab construction (e.g.) brick wall, and separated from other parts of establishment. A half-hour fire resistance (CRF30) solid wood door with a thickness of 5 cm and automatic shutter fittings must be installed. 14. Opening area (food transfer passage by wall) of establishment kitchen and dining area should not exceed 0.2m2. Additionally, a half-hour resistant (CRF30) fire-fighting gate that closes manually or automatically should be considered. 15. Air or smoke extraction or ventilation shaft in establishment must be made or installed with inflammable materials. It should not block operation of fixed automatic sprinkler system. If it needs to pass through an unspecified area or a premise with a different function, one-hour fire resistance (CRF60) materials should be used in construction. 16. If kitchen for cooking noodles or porridge is located on side of the sole exit of establishment, only an electric stove may be used. 17. If stoves in kitchen are used solely for cooking noodles or congee, and the fuel used comprises 20 litres of kerosene, diesel or electricity, aforementioned Articles 13 and 15 may be exempted. 1.5.2 General requirements 1. Levels and ceilings - Ceilings of all areas (kitchens, store room, sanitary devices, dining area or drinking area, passageways or other areas) should be made of firm, solid, non-flammable, anti-corrosive, easily cleanable, sterilized materials; - Except for washrooms and corridors, areas for customers’ use should not measure less than 2.60m high. In a five-star or four-star hotel, the height should not be less than 3.50m. In a three-star or two-star hotel, the height should not be less than 3.00m. If the areas are equipped with air conditioner to ensure good ventilation, 5 cm lower in height can be allowed. - If there is false ceiling, the lowest height between the false ceiling and floorboards must be the same as the aforementioned regulation. - If successive false ceilings unavoidable, the upper space of each area must not be linked to upper space of connected areas. 23
Application Process for the Licensing of Restaurants, Bars and Nightclubs - Kitchens and storerooms not permitted undertake decorations, which may result in lack of access for inspection and cleaning, such as false ceiling. 2. Walls - Walls of all areas (kitchens, storerooms, sanitary devices, drinking area and/or dining area, passageways or other areas) must be made of smooth, firm, inflammable, anti-corrosive, easily cleanable, sterilized materials; - Walls of kitchens and sanitary devices and their connected passageways should be made of ceramic tiles, marble or any smooth, waterproof, light-coloured materials 1.5m or more; - Kitchens, storerooms and sanitary devices must not be decorated in a manner, which obstructs inspection, cleaning and sterilization, such as the use of wall panels. 3. Floorboards Floorboards in all areas (kitchens, store rooms, sanitary devices, drinking area and/or dining area, passageways and other areas) should be made of smooth, slip-proof, firm, waterproof, inflammable, anti-corrosive, easily- cleanable, sterilized materials. 4. All restaurants, nightclubs, bars and other establishments must contain following areas, of a size regulated by relevant regulations consistent with maximum customer capacity: - Customer area and dining area; - Sanitary devices; - Kitchen; - Store rooms or warehouse; - Refrigerating facilities including freezing compartment. 5. The area of the kitchens, store rooms and/or warehouses must be in proportion to total area of establishment and conform to minimum area stated in appendix of “Hotel Industry and Similar Industries Regulations” approved by “Portaria 83/96/M” dated 1st April (more details in appendix I). 6. Kitchens, storerooms and sanitary devices must not undertake decorations which may obstruct access for inspection, cleaning and sterilization, such as 24
Application Process for the Licensing of Restaurants, Bars and Nightclubs the use of wall panels. 7. Dining area and/or drinking area, parlour and connected passageways must not undertake decorations, which may obstruct access for inspection, cleaning and sterilization, such as use of wall panels or false wall. 8. Recommended that establishments such as restaurants, nightclubs and bars install a pantry consistent with maximum customer capacity for storing tablecloths, cups, plates, forks, knives and tableware supplied for customers’ use. If amenities not sufficient, a special cupboard should be made available. The cupboard should always be closed and covered with materials, which are waterproof, ventilated, easy cleanable, and can repel dust, mice and cockroaches. 9. All establishments must provide covered containers for collecting garbage, with capacity adapted to number of customers and frequency. 10. Establishments may not be used for residential purposes, even temporarily. 1.5.3 Kitchens 1. Kitchens must provide sufficient lighting and direct and artificial ventilation installation; 2. Kitchens must install ventilation, smoke and odour-absorbing and eliminating devices; 3. The smallest area of kitchen should conform to regulations in Table I of Appendix I; 4. Surfaces of floorboards, walls, ceilings and other supporting facilities in kitchens should be made of firm, waterproof, anti-corrosive, easily cleanable materials; 5. Floorboards of kitchens and pantries must be made of slip-proof materials, and equipped and designed with conveniently angled drainage fittings; 6. Walls must be level and smooth to the ceiling. The connecting point with floorboards and other walls should be arc shaped; 25
Application Process for the Licensing of Restaurants, Bars and Nightclubs 7. Operation area must avoid dissemination of odours and constructed to prevent noise, vibration and odious smells; 8. Food handlers must always keep their hands clean. The entrance to kitchens and suitable areas in kitchens must be installed with washbasin for staff members on a proportion of 1 sink per 20 staff members and, must be installed with siphon bend and connected to public sewage system. Liquid soap and individual towel dispenser or electric hand dryer must be made available; 9. Kitchen interior must contain designated space for cookers, cutlery and tableware (recommend each 1m2 in kitchen reserve 0.02m3 for kitchen cupboard); 10. All establishments such as restaurants, nightclubs and bars must be equipped with refrigerating facilities with temperature monitor and warning system, to preserve food and beverages; to be consistent with maximum customer capacity and food and drink characteristics; 11. Racks, tables, cupboards and operation tables must be made of smooth, firm, waterproof, anti-corrosive, easily cleanable materials (such as stainless steel). Items must also be consistent with activities of establishment and maximum customer capacity; 12. Boards made of wood or other materials must not be laid on floor of kitchens; 13. Personal possessions, including clothing, shoes, socks, luggage, rain gear, washing articles, may not be stored or put in kitchens and food storage areas; 14. All establishments such as restaurants, nightclubs and bars must be equipped with areas for storing food and beverages and glass bottles consistent with establishment characteristics and maximum customer capacity. 1.5.4 Sanitary devices 1. All sanitary devices must have running water and functioning area must be appropriate and safe; 2. Doors of sanitary devices must be fitted with self-closing door hinges; 26
Application Process for the Licensing of Restaurants, Bars and Nightclubs 3. Sanitary devices must be equipped with direct or artificial ventilation devices for continuous renewal of air; 4. Walls, floorboards and ceiling must be decorated with waterproof, anti-corrosive, easily cleanable materials; 5. Floorboards must be provided with convenient drainage devices; 6. Sanitary devices may not be directly connected to areas used for storing, preserving and preparing food products. They must be located in appropriate places not directly facing customer areas; 7. Sanitary devices must be separated according to gender. Sanitary devices for staff members only must be installed; 8. Minimum number of sanitary devices for customers must be consistent with basic requirements in Table II of Appendix I; 9. Minimum of one toilet and sink must be provided for 40 male staff members and 30 female staff members; 10. Sanitary devices must be equipped with liquid soap and individual towel dispenser or electric hand dryer, as well as necessary sanitary articles, lighting and fixed mirrors. Each toilet cubicle must always contain toilet paper; 11. Health department neither encourages nor recommends establishments not be equipped with toilets exclusively for customers and staff members. If restaurants, nightclubs and bars are not equipped with sanitary devices, but are equipped in commercial buildings or plazas for customers and staff members of food and drink establishments, this should be stated in application for licence. Regional hygiene supervisors will provide opinions according to circumstances; 12. Sanitary devices should always be clean and in good operation. 1.5.5 Refrigerators 1. Refrigeration facilities must provide appropriate lighting; 2. Refrigeration facilities must be installed with appropriate warning systems 27
Application Process for the Licensing of Restaurants, Bars and Nightclubs such as alarms; 3. Floors of refrigeration facilities must be clean and dry; 1.5.6 Food lifts 1. Food lift must be easily cleanable and constructed entirely of stainless steel. All shelves must be removable for easy cleaning; 2. If there is only one food lift in an establishment such as a restaurant, a nightclub or a bar: - The lift must carry food and clean tableware only; or - The lift must be divided into two levels. The upper level is for food and clean tableware, and the lower level is for remains of meals and dirty tableware. 3. If an establishment such as a restaurant, a nightclub or a bar are equipped with more than one food lift, each fit lift must clearly indicate designated use (e.g.) wording such as ‘Food and Clean Tableware Only’ or ‘Dirty Tableware Only’ must be indicated at eye level. 1.5.7 Lighting and ventilation systems 1. All establishments must be equipped with appropriate lighting and ventilation. Natural methods more desirable but artificial lighting and ventilation facilities or devices may be adopted to improve condition of environment; 2. If natural breeze is insufficient or impossible to obtain, establishments must install sustainable fresh air facilities to increase artificial ventilation. Recommended that fresh air entrance and exhaust gas exit installed at least 2.5m high above ground outside establishment; 3. Increased ventilation must supply minimum 17m3/hr for each person. Individual air entrance and exit must be installed in different sites of establishment; 4. Fresh air entrance and exhaust gas exit must not be too close to avoid fumes of exhaust gas; 28
Application Process for the Licensing of Restaurants, Bars and Nightclubs 5. All air-ducts must be constructed to prevent entry of mice; 6. Exhaust device of ventilation system must not be installed in places that may cause disturbance or inconvenience to public. 1.5.8 Grease interceptor 1. There must be enough space for installing a sufficient number of grease interceptors; 2. All grease and wastewater collected from kitchens, including wastewater from water troughs, wash tanks and sewage ditches on the ground, must pass through a grease interceptor of sufficient capacity before wastewater discharged to public drainage system; 3. Grease interceptors must be concealed on or underground; 4. Grease interceptors must be installed in washing area, far from food preparation and storage areas. 1.5.9 Ventilator 1. Kitchens must install air-extracting facilities; 2. Partial air-extracting facilities must be installed above stoves; 3. Air-extracting fans must be equipped with protection casing (electric fan lid). 1.5.10 Fuel facilities All flammable materials, such as petroleum gas and gasoline, must be placed in protected areas, which are inflammable and appropriately ventilated. 1.5.11 Soot filter and aroma elimination system Kitchens and other areas used for food preparation and cooking must be installed with effective soot filter system appropriate for function of areas for collection and elimination of odours. Their operation must not inconvenience or harm third parties. 1.5.12 Sewage disposal system Wastewater in establishments must directly be directed to public sewage system, and all wastewater emission facilities (such as sinks, water troughs, washing tubs, toilet bowls, troughs and bathtubs) must be installed with siphon bend and trap. 1.5.13 Drainage system Kitchen floors, panty and sanitary devices must slightly incline to the channel cover or similar water outlet, so that water can drain away in that direction. 1.5.14 Water supply system 29
You can also read