Township of Muskoka Lakes Request for Tender - T-2020-17 Supply and Deliver One (1) New PUMPER FIRE APPARATUS DOOR

Page created by Nicholas Barker
 
CONTINUE READING
Township of Muskoka Lakes Request for Tender - T-2020-17 Supply and Deliver One (1) New PUMPER FIRE APPARATUS DOOR
Township of Muskoka Lakes

    Request for Tender

        T-2020-17

     Supply and Deliver
 One (1) New PUMPER FIRE
APPARATUS 4 X 4 – 2 DOOR
Township of Muskoka Lakes Request for Tender - T-2020-17 Supply and Deliver One (1) New PUMPER FIRE APPARATUS DOOR
TOWNSHIP OF MUSKOKA LAKES

                                 CONTENTS

Section A   Tender

Section B   Form of Agreement

Section C   Special Provisions
Township of Muskoka Lakes Request for Tender - T-2020-17 Supply and Deliver One (1) New PUMPER FIRE APPARATUS DOOR
SECTION A

 TENDER
Township of Muskoka Lakes Request for Tender - T-2020-17 Supply and Deliver One (1) New PUMPER FIRE APPARATUS DOOR
TOWNSHIP OF MUSKOKA LAKES

                                               INDEX TO TENDER

PART I         TENDER CALL ........................................................................................................... 1
PART II        TENDER CONDITIONS ............................................................................................. 2
   TC-1        Completion and Submissions of Tenders ..................................................................... 2
   TC-2        Basis of Award ............................................................................................................. 2
   TC-3        Addenda ........................................................................................................................ 3
   TC-4        Irregular Tenders .......................................................................................................... 3
   TC-5        Unbalanced Tenders ..................................................................................................... 3
   TC-6        Collusion....................................................................................................................... 3
   TC-7        Right to Accept or Reject Tenders................................................................................ 3
   TC-8        Contract Documents ..................................................................................................... 4
   TC-9        Errors, Omissions and Discrepancies in the Contract Documents................................ 4
   TC-10       Irrevocability of Offer ................................................................................................... 4
   TC-11       Successful Tenderer - WSIB Certificate of Clearance ................................................. 4
   TC-12       Successful Tenderer - Execution of Form of Agreement ............................................. 4
   TC-13       Successful Tenderer - Time for Completion ................................................................ 4
   TC-14       Successful Tenderer - Submission of Documentation .................................................. 5
   TC-15       Successful Tenderer - Commencement of the Work .................................................... 5
   TC-16       Successful Tenderer - Vendor Performance Management Notice ............................... 5
PART III - FORM OF TENDER .................................................................................................... 6
   FT-1        Contract Documents ..................................................................................................... 6
   FT-2        Schedule of Specifications............................................................................................ 6
   FT-3        Tenderer’s Declarations .............................................................................................. 10
   FT-4        Tenderer’s Offer ......................................................................................................... 11
   FT-5        Schedule of Prices....................................................................................................... 11
Township of Muskoka Lakes Request for Tender - T-2020-17 Supply and Deliver One (1) New PUMPER FIRE APPARATUS DOOR
TOWNSHIP OF MUSKOKA LAKES

                                           TENDER
  PART I        TENDER CALL

  The Corporation of the Township of Muskoka Lakes (after this called the “Owner”) invites
  Tenders for:

                            Contract Number: T-2020-17

                            Described as         Supply and Deliver

                                                One (1) New PUMPER FIRE APPARATUS
                                                    4 X 4 – 2 DOOR

Tenders shall be addressed and delivered to:        Fire Chief – Ryan Murrell
                                                    TENDER #T-2020-17
                                                    Muskoka Lakes Fire Department
                                                    P.O. Box 129
                                                    1 Bailey Street
                                                    Port Carling, ON
                                                    P0B 1J0

 Tenders shall be received until:                2:00 p.m. Wednesday, June 24, 2020

 Tenders received by the time and date specified above shall be opened and read in public as
 soon as possible after that time. Public reading of a Tender does not imply any decision by the
 Owner as to whether a Tender is or is not irregular.

 Section A – Tender                                                                     Page A-1
Township of Muskoka Lakes Request for Tender - T-2020-17 Supply and Deliver One (1) New PUMPER FIRE APPARATUS DOOR
PART II     TENDER CONDITIONS

TC-1       Completion and Submissions of Tenders

1.1        The Tenderer shall complete all documents pertaining to this Contract in ink or in
           type.

1.2        If the Tenderer is a corporation, an authorized officer of the corporation shall sign
           and seal the Form of Tender.

1.3        If the Tenderer is a partnership, a minimum of two partners shall sign the Form of
           Tender and signatures shall be witnessed.

1.4        If the Tenderer is a sole proprietorship, the sole proprietor shall sign the Form of
           Tender and the signature shall be witnessed.

1.5        The Tenderer shall submit its Tender by the date and time specified in Part I of the
           Tender.

1.6        The Tenderer shall submit to the Owner:
           a) Part III – Form of Tender;

1.7        The Tenderer shall submit the Tender in a sealed and opaque envelope properly
           identified with the contract number, contract description, name of Tenderer, due
           date and time.

1.8        Tender irregularities will be dealt with in accordance with the Township of
           Muskoka Lakes Purchasing By-Law 2004-161, as amended.

1.9        All inquiries/questions regarding this Tender are to be sent via email to Ryan
           Murrell, Fire Chief at rmurrell@muskokalakes.ca. Inquiries must be received no
           later than five (5) Business Days prior to the tender submission deadline specified
           in Part I of the Tender or as amended by addendum. Unless otherwise addressed
           through an addendum, all responses to bid inquiries shall not be incorporated as
           part of the Contract or in any way change the Contract.

TC-2       Basis of Award

2.1        The Township intends to award the contract to bidder that best meets the operational
           needs of the Township and represents the best value for the Township. This will be
           determined through an examination of the conformance to specifications balanced
           with Total Tender Price. As such, lowest tender price may not necessarily be
           accepted.

Section A – Tender                                                                       Page A-2
TC-3       Addenda

3.1        Addenda will be posted on the Township website (www.muskokalakes.ca) for
           viewing and shall be located in the same area of the webpage that the Tender
           documents are downloaded from.

3.2        The Township will not notify Tenderers of addendums and it is the responsibility of
           the Tenderer to monitor the webpage and retrieve posted addendums prior to
           submitting their bid.

3.3        The Tenderer shall ensure that all addenda that are issued are acknowledged and
           listed under Section FT-1 of the Tender.

3.4        The deadline for the posting of addenda is no later than three (3) Business Days
           prior to tender submission deadline as specified in Part I of the Tender or as
           amended by addendum.

TC-4       Irregular Tenders

4.1        The Owner shall be the sole judge of whether or not a Tender is irregular.

TC-5       Unbalanced Tenders

5.1        The Tenderer shall not submit an unbalanced Tender.

5.2        The Owner shall have the right to:
           a) deem a Tender to be unbalanced; and
           b) reject a Tender which it deems to be unbalanced.

TC-6       Collusion

6.1        The Tenderer shall not engage in collusion of any sort and, in particular, shall:
           a) ensure that no person or other legal entity, other than the Tenderer, has any
              undisclosed interest in the Tenderer’s Tender; and
           b) prepare its Tender without any knowledge of, comparison of figures with or
              arrangement with any other person or firm preparing a Tender for the same
              work.

TC-7       Right to Accept or Reject Tenders

7.1        Notwithstanding any other provision in this Contract, the Owner shall have the right
           to:
           a) accept any Tender;
           b) reject any Tender; and
           c) reject all Tenders.

Section A – Tender                                                                      Page A-3
7.2        Without limiting the generality of Section TC-7.1, the Owner shall have the right to:
           a) accept an irregular Tender;
           b) accept a Tender which is not the lowest Tender; and
           c) reject a Tender even if it is the only Tender received by the Owner.

7.3        Acceptance of the Tender shall occur at the time the Owner awards the Tender and
           not necessarily at the time the award is communicated to the successful Tenderer.

TC-8       Contract Documents

8.1        The Tenderer shall obtain and review all Contract Documents as listed in the Form
           of Tender including all Addenda issued by the Owner pertaining to this Contract.

TC-9       Errors, Omissions and Discrepancies in the Contract Documents

9.1        If the Tenderer finds any errors or omissions in or discrepancies among the Contract
           Documents, it shall immediately notify the Owner at the address specified in Part I
           of the Tender.

9.2        No oral explanation or interpretation by any person shall modify any of the
           Contract Documents.

TC-10      Irrevocability of Offer

10.1       The Tenderer shall not revoke its offer until after the expiration of sixty (60) days
           after the opening of Tenders by the Owner.

TC-11      Successful Tenderer - WSIB Certificate of Clearance

11.1       The successful Tenderer shall provide the Owner with a valid Workplace Safety &
           Insurance Board Certificate of Clearance to the satisfaction of the Owner.

TC-12      Successful Tenderer - Execution of Form of Agreement

12.1       The successful Tenderer shall execute in accordance with TC-1, in triplicate, the
           Form of Agreement provided in the Contract Documents.

12.2       The successful Tenderer shall forward the executed Form of Agreement to the
           Owner.

TC-13      Successful Tenderer - Time for Completion

 13.1      The successful Tenderer shall complete the work by December 31, 2020.

 13.2      The successful Tenderer acknowledges that time shall be deemed to be of the
           essence of the Contract. For the Tenderer’s purpose of establishing a schedule for

Section A – Tender                                                                       Page A-4
the Work, it is anticipated that contract award will be complete within 30 calendar
           days after the opening of tenders by the Owner. Upon notice of award, the
           successful Tenderer will be required to complete submissions to the Owner as per
           TC-14.1. Upon receipt of all required submissions from the successful Tenderer,
           the Owner will return an executed Form of Agreement and a Purchase Order to the
           Tenderer within 10 Business Days.

 13.3      Milestone dates associated with the Contract will be adjusted, when possible, due to
           any delays to the anticipated award schedule caused by the Owner during the
           contract award and/or issuance of the authorization to commence work.

TC-14      Successful Tenderer - Submission of Documentation

14.1       The successful Tenderer shall submit the documentation required by Sections TC-11
           and TC-12 within seven (7) calendar days of the day the Owner notifies the
           successful Tenderer that the documentation should be sent to the Owner.

14.2       If the successful Tenderer fails to comply with Section TC-14.1 the Owner may, in
           its sole discretion, withdraw its acceptance of the Tender and the Tenderer shall
           have no recourse whatsoever against the Owner.

TC-15      Successful Tenderer - Commencement of the Work

15.1       The successful Tenderer shall not commence the Work until it has received authority
           to proceed with the work from the Owner as well as the fully executed Form of
           Agreement signed by both parties (Tenderer and Owner) and a Purchase Order
           issued by the Owner.

TC-16      Successful Tenderer - Vendor Performance Management Notice

16.1       The contract resulting from this Tender may be subject to performance evaluation
           conducted by the Owner. The Owner reserves the right to consider the results of this
           performance evaluation in the award of future contracts and/or in the selection of
           vendors for future work. Performance evaluation will be managed in accordance
           with Township policy HS-007-POL, “Contractor Activities and Control Policy” and
           Township Procurement Policy By-law 2004-161, as amended.

Section A – Tender                                                                   Page A-5
TOWNSHIP OF MUSKOKA LAKES

                          PART III - FORM OF TENDER
Tender by:

                           NAME OF TENDERER

                           ADDRESS OF TENDERER                       TELEPHONE NUMBER

                                                                               FAX NUMBER

                                                                                      E-MAIL

after this called the “Tenderer”.

FT-1         Contract Documents

1.1          The Contract Documents for Contract Number T-2020-17 are:
             a) Tender
                 i) Part I - Tender Call
                 ii) Part II - Tender Conditions
                 iii) Part III - Form of Tender
             b) Form of Agreement
             c) Special Provisions
             d) All Addenda issued pertaining to the Contract as acknowledged below:
                Addendum No. dated ________________ , 20             , No. of Pages
                Addendum No. dated ________________ , 20             , No. of Pages
                Addendum No. dated ________________ , 20             , No. of Pages
                Addendum No. dated ________________ , 20             , No. of Pages

FT-2         Schedule of Specifications

2.1          The Schedule of Specifications attached is Section FT-2.5 of the Tender. The
             Schedule of Specifications shall form an integral part of the tender submission and
             must be completed in its entirety and returned with the tender submission.

2.2          All equipment shall conform to the latest laws, rules and regulations in the Province
             of Ontario. The vehicle shall meet or surpass all relevant requirements of the

Section A – Tender                                                                      Page A-6
Canadian Motor Vehicle Safety Standards at the date of vehicle and equipment
           manufacture.

2.3        Only standard factory approved makes and models shall be included in this tender.
           The vehicle shall be equipped with all standard features for the quoted make and
           model plus anything outlined in this specification if not standard. Vehicles shall be
           supplied only with the standard or advertised optional engine for the vehicle being
           bid. Vehicles with non-advertised or altered engine horsepower settings will not be
           accepted. Only currently advertised and factory approved engine and drive train
           combinations are acceptable. Only the major details of the vehicle are listed. It is the
           supplier’s responsibility to deliver a fully equipped vehicle with compatible
           components to provide dependable efficient service. Where minimums are given, the
           vehicle must meet or exceed the capacity, size, or performance specified. All
           components of the vehicle must be new including any related attachments.

2.4        For each of the specific requirements, please indicate if the equipment supplied
           conforms to the Township of Muskoka Lakes actual specification by circling “yes”
           or “no” in each column as provided. If prompted, please specify the details of the
           vehicle in the space provided. For any specific requirements that do not conform to
           the specifications provided, please circle “no” in the column provided and indicate
           the manufacturer's actual specification in the space provided on the Specification
           Sheet. For any specific requirements that do not conform to the specifications
           provided, please provide additional supporting information on a separate sheet of
           paper and/or supply product specification information and pamphlets supporting the
           deviation for review. If a particular manufacturer does not offer a model or option
           that meets a particular specification in this tender, deviation will be considered at the
           discretion of the Director of Public Works. The Township reserves the right to
           review all stated deviations to determine acceptance or non-acceptance as best meets
           the needs of the Township, without penalty.

Section A – Tender                                                                       Page A-7
FT-2.5 SCHEDULE OF SPECIFICATIONS

                                       Item 1 – PUMPER FIRE
                                     APPARATUS 4 X 4 – 2 DOOR
 1.   VEHICLE INFORMATION

      Specify year, make, model and estimated           YEAR:
      date of delivery of the vehicle being
      tendered.                                         MAKE:

      Must be a new vehicle 2020 model year or          MODEL:
      newer
                                                        DELVERY DATE:

 2.   COMMERCIAL MOTOR VEHICLE SAFETY ACT COMPLIANCE:
      Vehicles shall meet or surpass the mandatory
      requirements of the Canada Motor Vehicle
      Safety Act and its Regulations in effect on the   YES     NO
      date of manufacture and the vehicle must bear
      the
      National Safety Mark.

 3.   MINIMUM VEHICLE SPECIFCATIONS:
      A FREIGHTLINER TWO DOOR M2 106                    YES     NO   SPECIFY GVWR:
      CONVENTIONAL CHASSIS
      MEDIUM TRUCK WARRANTY                             YES     NO   SPECIFY:

      EXPECTED FRONT AXLE(S) LOAD: 16,000               YES     NO   SPECIFY:
      LBS
      EXPECTED REAR AXLE(S) LOAD: 30,000                YES     NO   SPECIFY:
      LBS

      FIRE PUMPER – MAIN DRIVELINE                      YES     NO   SPECIFY:
      DRIVEN SPLIT-SHAFT PTO PUMP
      EXPECTED BODY CENTRE OF GRAVITY                   YES     NO   SPECIFY:
      32 INCHES ABOVE FRAME

      CUMMINS L9 ENGINE CAPABLE OF 330
      EV HP @2000 RPM, 2200 GOV RPM                     YES     NO   SPECIFY:

      120 KM/H ROAD SPEED LIMIT (75MPH)
                                                        YES     NO   SPECIFY:

      CRUISE CONTROL SPEED LIMT SAME AS
      ROAD                              YES                     NO SPECIFY:

Section A – Tender                                                                   Page A-8
PTO MODE BRAKE OVERRIDE WHEN
                                           YES   NO   SPECIFY:
      SERVICE BRAKE APPLIED
      PTO RPM WITH CRUISE SET SWITCH 1100
      RPM                                 YES    NO   SPECIFY:

      PTO MODE CANCEL VEHICLE SPEED – 5
                                           YES   NO   SPECIFY:
      MPH
      PTO GOVERNOR RAMP RATE – 250 RPM /
      SEC                                YES     NO   SPECIFY:

      FUEL DOSING OF AFTERTREATMENT
                                           YES   NO   SPECIFY:
      ENABLED IN PTO MODE-CLEANS
      HYDROCARBONS AT HIGH
      TEMPERATURES ONLY
      PTO MINIMUM RPM - 700
                                           YES   NO   SPECIFY:

      REGEN INHIBIT SPEED THRESHOLD - 5
      MPH                                  YES   NO   SPECIFY:

      2016-2019 ONBOARD DIAGNOSTICS/2010
      EPA/CARB/FINAL GHG17                 YES   NO   SPECIFY:
      CONFIGURATION
      NO 2008 CARB EMISSION
      CERTIFICATION                        YES   NO   SPECIFY:

      SIDE OF HOOD AIR INTAKE WITH NFPA
      COMPLIANT EMBER SCREEN AND FIRE      YES   NO   SPECIFY:
      RETARDANT DONALDSON AIR
      CLEANER

      DR 12V 275 AMP 40-SI BRUSHLESS PAD
                                           YES   NO   SPECIFY:
      ALTERNATOR WITH REMOTE BATTERY
      VOLTAGE SENSE
      (2) DTNA GENUINE, FLOODED
      STARTING, MIN 2000CCA, 370RC,        YES   NO   SPECIFY:
      THREADED STUD BATTERIES
      BATTERY BOX FRAME MOUNTED
                                           YES   NO   SPECIFY:

      STANDARD BATTERY JUMPERS
                                           YES   NO   SPECIFY:

      SINGLE BATTERY BOX FRAME
      MOUNTED LH SIDE UNDER CAB            YES   NO   SPECIFY:

      NON-POLISHED BATTERY BOX COVER
                                           YES   NO   SPECIFY:

      CAB AUXILIARY POWER CABLE
                                           YES   NO   SPECIFY:

      POSITIVE LOAD DISCONNECT WITH CAB
                                        YES      NO   SPECIFY:
      MOUNTED CONTROL SWITCH MOUNTED
      OUTBOARD DRIVER SEAT
      POSITIVE AND NEGATIVE POSTS FOR
      JUMPSTART LOCATED ON FRAME NEXT YES        NO   SPECIFY:
      TO STARTER
Section A – Tender                                               Page A-9
CUMMINS TURBOCHARGED 18.7 CFM AIR
     COMPRESSOR WITH INTERNAL SAFETY   YES    NO   SPECIFY:
     VALVE
     STANDARD MECHANICAL AIR
     COMPRESSOR GOVERNOR                YES   NO   SPECIFY:

     AIR COMPRESSOR DISCHARGE LINE
                                        YES   NO   SPECIFY:

     GVG, FIRE AND EMERGENCY SERVICE
     VEHICLES ENGINE WARNING            YES   NO   SPECIFY:

     CUMMINS EXHAUST BRAKE INTEGRAL
                                        YES   NO   SPECIFY:
     WITH VARIABLE GEOMETRY TURBO
     WITH ON/OFF DASH SWITCH

     RH OUTBOARD UNDER STEP MOUNTED
     HORIZONTAL AFTERTREATMENT          YES   NO   SPECIFY:
     SYSTEM ASSEMBLY WITH RH
     HORIZONTAL TAILPIPE EXITING
     FORWARD OF REAR TIRES

     ENGINE AFTERTREATMENT DEVICE,
     AUTOMATIC OVER THE ROAD ACTIVE     YES   NO   SPECIFY:
     REGENERATION AND DASH MOUNTED
     SINGLE REGENERATION
     REQUEST/INHIBIT SWITCH

     STANDARD EXHAUST SYSTEM LENGTH     YES   NO   SPECIFY:

     RH HORIZONTAL TAILPIPE, EXIT       YES   NO   SPECIFY:
     FORWARD OF REAR TIRES AT 90
     DEGREES

     6 GALLON DIESEL EXHAUST FLUID TANK YES   NO   SPECIFY:

     100 PERCENT DIESEL EXHAUST FLUID   YES   NO   SPECIFY
     FILL

     LH MEDIUM DUTY STANDARD DIESEL     YES   NO   SPECIFY
     EXHAUST FLUID TANK LOCATION

     STANDARD DIESEL EXHAUST FLUID      YES   NO   SPECIFY
     PUMP MOUNTING

     STANDARD DIESEL EXHAUST FLUID      YES   NO   SPECIFY
     TANK CAP
     BORG WARNER (KYSOR) REAR AIR       YES   NO   SPECIFY
     ON/OFF ENGINE FAN CLUTCH

Section A – Tender                                            Page A-10
AUTOMATIC FAN CONTROL WITH           YES   NO   SPECIFY
     DASH SWITCH AND INDICATOR LIGHT,
     NON ENGINE MOUNTED
     CUMMINS SPIN ON FUEL FILTER          YES   NO   SPECIFY

     COMBINATION FULL FLOW/BYPASS OIL     YES   NO   SPECIFY
     FILTER
     1100 SQUARE INCH ALUMINUM            YES   NO   SPECIFY
     RADIATOR
     ANTIFREEZE TO -60F, OAT (NITRITE &   YES   NO   SPECIFY
     SILICATE FREE) EXTENDED LIFE
     COOLANT
     GATES BLUE STRIPE COOLANT HOSES      YES   NO   SPECIFY
     OR EQUIVALENT
     CONSTANT TENSION HOSE CLAMPS         YES   NO   SPECIFY
     FOR COOLANT HOSES
     RADIATOR DRAIN VALVE                 YES   NO   SPECIFY

     LOWER RADIATOR GUARD                 YES   NO   SPECIFY

     PHILLIPS-TEMRO 1000 WATT/115 VOLT    YES   NO   SPECIFY
     BLOCK HEATER
     CHROME ENGINE HEATER RECEPTACLE      YES   NO   SPECIFY
     MOUNTED UNDER LH DOOR
     ALUMINUM FLYWHEEL HOUSING            YES   NO   SPECIFY

     ELECTRIC GRID AIR INTAKE WARMER      YES   NO   SPECIFY

     DELCO 12V 39MT HD/OCP STARTER WITH YES     NO   SPECIFY
     THERMAL PROTECTION AND
     INTEGRATED MAGNETIC SWITCH

     ALLISON 3000 EVS AUTOMATIC           YES   NO   SPECIFY
     TRANSMISSION WITH PTO PROVISION

     ALLISON VOCATIONAL PACKAGE 198 -     YES   NO   SPECIFY
     AVAILABLE ON 3000/4000 PRODUCT
     FAMILIES W/ VOCATIONAL MODEL EVS

     ALLISON VOCATIONAL RATING FOR FIRE YES     NO   SPECIFY
     TRUCK/EMERGENCY VEHICLE
     APPLICATIONS AVAILABLE WITH ALL
     PRODUCT FAMILIES

     PRIMARY MODE GEARS, LOWEST GEAR 1, YES     NO   SPECIFY
     START GEAR 1, HIGHEST GEAR 6,
     AVAILABLE FOR 3000/4000 PRODUCT
     FAMILIES ONLY

Section A – Tender                                             Page A-11
SECONDARY MODE GEARS, LOWEST          YES   NO   SPECIFY
     GEAR 1, START GEAR 1, HIGHEST GEAR 6,
     AVAILABLE FOR 3000/4000 PRODUCT
     FAMILIES ONLY

     PRIMARY SHIFT SCHEDULE           YES        NO   SPECIFY
     RECOMMENDED BY DTNA AND ALLISON,
     THIS DEFINED BY ENGINE AND
     VOCATIONAL USAGE

     SECONDARY SHIFT SCHEDULE             YES    NO   SPECIFY
     RECOMMENDED BY DTNA & ALLISON,
     THIS DEFINED BY ENGINE &
     VOCATIONAL USAGE

     PRIMARY SHIFT SPEED RECOMMENDED      YES    NO   SPECIFY
     BY DTNA AND ALLISON, THIS DEFINED
     BY ENGINE AND VOCATIONAL USAGE

     SECONDARY SHIFT SPEED            YES        NO   SPECIFY
     RECOMMENDED BY DTNA AND ALLISON,
     THIS DEFINED BY ENGINE AND
     VOCATIONAL USAGE

     ENGINE BRAKE RANGE PRESELECT     YES        NO   SPECIFY
     RECOMMENDED BY DTNA AND ALLISON,
     THIS DEFINED BY ENGINE AND
     VOCATIONAL USAGE

     ENGINE BRAKE RANGE ALTERNATE        YES     NO   SPECIFY
     PRESELECT RECOMMENDED BY DTNA
     AND ALLISON, THIS DEFINED BY ENGINE
     AND VOCATIONAL USAGE

     FUEL SENSE 2.0 DISABLED -            YES    NO   SPECIFY
     PERFORMANCE - TABLE BASED

     DRIVER SWITCH INPUT - DEFAULT - NO   YES    NO   SPECIFY
     SWITCHES

     DIRECTION CHANGE ENABLED WITH        YES    NO   SPECIFY
     MULTIPLEXED SERVICE BRAKES -
     ALLISON 5TH GEN TRANSMISSIONS

     PUMP MODE INPUT ENABLED 3RD/4TH      YES    NO   SPECIFY
     LOCKUP WIRED ON TCM INPUT AJ/BQ -
     ALLISON 5TH GEN TRANSMISSIONS

     VEHICLE INTERFACE WIRING         YES        NO   SPECIFY
     CONNECTOR WITHOUT BLUNT CUTS, AT
     BACK OF CAB

Section A – Tender                                              Page A-12
ELECTRONIC TRANSMISSION CUSTOMER YES        NO   SPECIFY
     ACCESS CONNECTOR FIREWALL
     MOUNTED

     PTO, TRANSFER CASE MOUNTED           YES    NO   SPECIFY

     (2) CUSTOMER INSTALLED CHELSEA 280   YES    NO   SPECIFY
     SERIES PTO'S

     PTO MOUNTING, LH SIDE AND TOP RH     YES    NO   SPECIFY
     SIDE OF MAIN TRANSMISSION

     MAGNETIC PLUGS, ENGINE DRAIN,        YES    NO   SPECIFY
     TRANSMISSION DRAIN, AXLE(S) FILL
     AND DRAIN

     PUSH BUTTON ELECTRONIC SHIFT         YES    NO   SPECIFY
     CONTROL, DASH MOUNTED

     TRANSMISSION PROGNOSTICS -           YES    NO   SPECIFY
     ENABLED 2013

     WATER TO OIL TRANSMISSION COOLER, YES       NO   SPECIFY
     IN RADIATOR END TANK

     MERITOR MTC-4210 AND MTC-4213        YES    NO   SPECIFY
     TRANSFER CASE OIL COOLER

     TRANSMISSION OIL CHECK AND FILL      YES    NO   SPECIFY
     WITH ELECTRONIC OIL LEVEL CHECK

     MERITOR MTC 4210XP 2-SPEED           YES    NO   SPECIFY
     TRANSFER CASE

     TRANSFER CASE SHIFT CONTROLS WITH YES       NO   SPECIFY
     TRANSFER CASE PTO ON/OFF SWITCH
     WHEN APPLICABLE

     SYNTHETIC TRANSMISSION FLUID (TES-   YES    NO   SPECIFY
     295 COMPLIANT)

     MX-16-120HR 16,000# 1790MM KPI SINGLE YES   NO   SPECIFY
     FRONT DRIVE AXLE WITH HR CARRIER

     5.57 FRONT AXLE RATIO                YES    NO   SPECIFY

     MXL 16T MERITOR EXTENDED LUBE      YES      NO   SPECIFY
     FRONT STEERING AXLE DRIVELINE WITH
     HALF ROUND YOKES

     MERITOR 16.5X6 Q+ MX DRIVE AXLE      YES    NO   SPECIFY
     CAST SPIDER CAM FRONT BRAKES

Section A – Tender                                              Page A-13
FIRE AND EMERGENCY SEVERE SERVICE, YES       NO   SPECIFY
     NON-ASBESTOS FRONT LINING

     MERITOR CAST IRON FRONT BRAKE         YES    NO   SPECIFY
     DRUMS
     FRONT BRAKE DUST SHIELDS              YES    NO   SPECIFY

     FRONT GREASE SEAL                     YES    NO   SPECIFY

     STANDARD SPINDLE NUTS FOR ALL         YES    NO   SPECIFY
     AXLES
     MERITOR AUTOMATIC FRONT SLACK         YES    NO   SPECIFY
     ADJUSTERS
     TRW TAS-85 POWER STEERING             YES    NO   SPECIFY

     POWER STEERING PUMP                   YES    NO   SPECIFY

     2 QUART SEE THROUGH POWER             YES    NO   SPECIFY
     STEERING RESERVOIR
     OIL/AIR POWER STEERING COOLER         YES    NO   SPECIFY

     SYNTHETIC 75W-90 FRONT AXLE LUBE      YES    NO   SPECIFY

     16,000# TAPERLEAF FRONT SUSPENSION    YES    NO   SPECIFY

     MAINTENANCE FREE RUBBER BUSHINGS YES         NO   SPECIFY
     - FRONT SUSPENSION
     FRONT SUSPENSION WITH LEFT HAND       YES    NO   SPECIFY
     OFFSET SHACKLE BRACKET
     FRONT SHOCK ABSORBERS                 YES    NO   SPECIFY

     RS-30-185 30,000# U-SERIES SINGLE REAR YES   NO   SPECIFY
     AXLE
     5.63 REAR AXLE RATIO                  YES    NO   SPECIFY

     IRON REAR AXLE CARRIER WITH           YES    NO   SPECIFY
     STANDARD AXLE HOUSING
     MXL 17T MERITOR EXTENDED LUBE         YES    NO   SPECIFY
     MAIN DRIVELINE WITH HALF ROUND
     YOKES
     MXL 17T MERITOR EXTENDED LUBE         YES    NO   SPECIFY
     INTERTRANSMISSION DRIVELINE WITH
     HALF ROUND YOKES
     DRIVER CONTROLLED TRACTION            YES    NO   SPECIFY
     DIFFERENTIAL - SINGLE REAR AXLE

Section A – Tender                                               Page A-14
(1) DRIVER CONTROLLED DIFFERENTIAL   YES   NO   SPECIFY
     LOCK REAR VALVE FOR SINGLE DRIVE
     AXLE
     BLINKING LAMP WITH EACH MODE         YES   NO   SPECIFY
     SWITCH, DIFFERENTIAL UNLOCK WITH
     IGNITION OFF, ACTIVE
STD U.S. FRONT BRAKE VALVE              YES   NO   SPECIFY

     RELAY VALVE WITH 5-8 PSI CRACK      YES       NO   SPECIFY
     PRESSURE, NO REAR PROPORTIONING
     VALVE
     BW AD-9SI BRAKE LINE AIR DRYER WITH YES       NO   SPECIFY
     HEATER
     AIR DRYER MOUNTED INBOARD ON LH         YES   NO   SPECIFY
     RAIL
     STEEL AIR BRAKE RESERVOIRS              YES   NO   SPECIFY

     CLEAR FRAME RAILS FROM BACK OF      YES       NO   SPECIFY
     CAB TO FRONT REAR SUSPENSION
     BRACKET, BOTH RAILS OUTBOARD
     PULL CABLES ON ALL AIR RESERVOIR(S) YES       NO   SPECIFY

     UPGRADED CHASSIS MULTIPLEXING           YES   NO   SPECIFY
     UNIT
     UPGRADED BULKHEAD MULTIPLEXING          YES   NO   SPECIFY
     UNIT
     4750MM (187 INCH) WHEELBASE             YES   NO   SPECIFY

     11/32X3-1/2X10-15/16 INCH STEEL FRAME   YES   NO   SPECIFY
     (8.73MMX277.8MM/0.344X10.94 INCH)
     120KSI
     1525MM (60 INCH) REAR FRAME             YES   NO   SPECIFY
     OVERHANG
     FRAME OVERHANG RANGE: 51 INCH TO        YES   NO   SPECIFY
     60 INCH
     CALC'D BACK OF CAB TO REAR SUSP C/L YES       NO   SPECIFY
     (CA) : 121.46 in
     CALCULATED EFFECTIVE BACK OF CAB YES          NO   SPECIFY
     TO REAR SUSPENSION C/L (CA) : 116.96 in
     CALC'D FRAME LENGTH - OVERALL :         YES   NO   SPECIFY
     276.4
     CALCULATED FRAME SPACE LH SIDE :        YES   NO   SPECIFY
     86.74 in
     CALCULATED FRAME SPACE RH SIDE :        YES   NO   SPECIFY
     191.79 in
     CALC'D SPACE AVAILABLE FOR              YES   NO   SPECIFY
     DECKPLATE : 121.45 in
     SQUARE END OF FRAME                     YES   NO   SPECIFY

     REAR TOW HOOKS                          YES   NO   SPECIFY

Section A – Tender                                                Page A-16
FRONT CLOSING CROSSMEMBER          YES   NO   SPECIFY

     LIGHTWEIGHT HEAVY DUTY ALUMINUM YES      NO   SPECIFY
     ENGINE CROSSMEMBER
     STANDARD CROSSMEMBER BACK OF       YES   NO   SPECIFY
     TRANSMISSION
     STANDARD MIDSHIP #1                YES   NO   SPECIFY
     CROSSMEMBER(S)
     STANDARD REARMOST CROSSMEMBER      YES   NO   SPECIFY

     STANDARD SUSPENSION CROSSMEMBER YES      NO   SPECIFY

     THREE-PIECE 14 INCH CHROME STEEL YES     NO   SPECIFY
     BUMPER WITH COLLAPSIBLE ENDS AND
     LH WING CUTOUT FOR FEDERAL
     MS100/ES100/ES100C SPEAKER
     FRONT TOW HOOKS - FRAME MOUNTED YES      NO   SPECIFY

     BUMPER MOUNTING FOR SINGLE         YES   NO   SPECIFY
     LICENSE PLATE
     FENDER AND FRONT OF HOOD MOUNTED YES     NO   SPECIFY
     FRONT MUDFLAPS
     GRADE 8 THREADED HEX HEADED        YES   NO   SPECIFY
     FRAME FASTENERS
     D15-28195-000 MARK CENTERLINE OF   YES   NO   SPECIFY
     REAR SUSPENSION ON TOP FLANGE OF
     FRAME
     TANK BODY 0 TO 1500 GALLONS        YES   NO   SPECIFY

     50 GALLON/189 LITER SHORT        YES     NO   SPECIFY
     RECTANGULAR ALUMINUM FUEL TANK -
     LH
     RECTANGULAR FUEL TANK(S)         YES     NO   SPECIFY

     PLAIN ALUMINUM/PAINTED STEEL       YES   NO   SPECIFY
     FUEL/HYDRAULIC TANK(S) WITH
     PAINTED BANDS
     FUEL TANK(S) FORWARD               YES   NO   SPECIFY

     PLAIN STEP FINISH                  YES   NO   SPECIFY

     FUEL TANK CAP(S)                   YES   NO   SPECIFY

     DETROIT FUEL/WATER SEPARATOR WITH YES    NO   SPECIFY
     WATER IN FUEL SENSOR, HAND PRIMER
     AND 12 VOLT PREHEATER"

Section A – Tender                                           Page A-17
EQUIFLO INBOARD FUEL SYSTEM            YES   NO   SPECIFY

     NO NATURAL GAS VEHICLE FUEL TANK       YES   NO   SPECIFY
     VENT LINE/STACK
     AUXILIARY FUEL SUPPLY AND RETURN       YES   NO   SPECIFY
     PORTS LOCATED ON LH FUEL TANK
     HIGH TEMPERATURE REINFORCED            YES   NO   SPECIFY
     NYLON FUEL LINE
     MICHELIN XDN2 GRIP 315/80R22.5 20 PLY YES    NO   SPECIFY
     RADIAL FRONT TIRES
     MICHELIN XDN2 GRIP 315/80R22.5 20 PLY YES    NO   SPECIFY
     RADIAL REAR TIRES
     MERITOR IRON FRONT HUBS                YES   NO   SPECIFY

     WEBB IRON REAR HUBS                    YES   NO   SPECIFY

     ALCOA ULTRA ONE 89U64X 22.5X9.00 10- YES     NO   SPECIFY
     HUB PILOT 5.99 INSET ALUMINUM FRONT
     WHEELS

     ALCOA ULTRA ONE 89U64X 22.5X9.00 10-   YES   NO   SPECIFY
     HUB PILOT 5.99 INSET ALUMINUM REAR
     WHEELS

     POLISHED DISC SIDE FRONT WHEELS        YES   NO   SPECIFY
     WITH DURA-BRIGHT FINISH
     POLISHED OUTER (DISHED SIDE) REAR      YES   NO   SPECIFY
     WHEELS WITH OUTER ONLY DURA-
     BRIGHT FINISH

     NO FRONT HUB COVERS                    YES   NO   SPECIFY

     FRONT WHEEL MOUNTING NUTS              YES   NO   SPECIFY

     REAR WHEEL MOUNTING NUTS               YES   NO   SPECIFY

     INNER WHEEL EXTENSIONS, OUTBOARD YES         NO   SPECIFY
     AIRING, ALUMINUM OUTER WHEELS
     WITH RUBBER STABILIZERS

     106 INCH BBC FLAT ROOF ALUMINUM        YES   NO   SPECIFY
     CONVENTIONAL CAB
     AIR CAB MOUNTING                       YES   NO   SPECIFY

     NONREMOVABLE BUGSCREEN                 YES   NO   SPECIFY
     MOUNTED BEHIND GRILLE

Section A – Tender                                               Page A-18
2-1/2 INCH FENDER EXTENSIONS      YES   NO   SPECIFY

     LH AND RH GRAB HANDLES            YES   NO   SPECIFY

     HOOD MOUNTED CHROMED PLASTIC      YES   NO   SPECIFY
     GRILLE

     CHROME HOOD MOUNTED AIR INTAKE    YES   NO   SPECIFY
     GRILLE

     FIBERGLASS HOOD                   YES   NO   SPECIFY

     HOOD LINER, ADDED FIREWALL AND    YES   NO   SPECIFY
     FLOOR HEAT INSULATION

     DUAL 25 INCH ROUND STUTTER TONE  YES    NO   SPECIFY
     HOOD MOUNTED AIR HORNS WITH DUAL
     LANYARDS

     DUAL ELECTRIC HORNS               YES   NO   SPECIFY

     DUAL HORN SHIELDS                 YES   NO   SPECIFY

     ALL UNIT(S) KEYED ALIKE WITH      YES   NO   SPECIFY
     CUSTOMER SPECIFIED KEY NUMBER
     FT1013

     REAR LICENSE PLATE MOUNT END OF   YES   NO   SPECIFY
     FRAME

     LED HEADLIGHT ASSEMBLY AND        YES   NO   SPECIFY
     INCANDESCENT MARKER/TURN LAMP
     WITH CHROME BEZEL

     (5) AMBER MARKER LIGHTS           YES   NO   SPECIFY

     DAYTIME RUNNING LIGHTS            YES   NO   SPECIFY

     INTEGRAL STOP/TAIL/BACKUP LIGHTS  YES   NO   SPECIFY
     WITH 7 EXTRA FEET OF WIRE MOUNTED
     AT END OF FRAME

     STANDARD FRONT TURN SIGNAL LAMPS YES    NO   SPECIFY

     AUTOMATIC ON/OFF, ENGINE          YES   NO   SPECIFY
     COMPARTMENT, HOOD ACTIVATED
     WORK LIGHT WITH MANUAL OVERRIDE

Section A – Tender                                          Page A-19
DUAL WEST COAST BRIGHT FINISH      YES   NO   SPECIFY
     HEATED MIRRORS WITH LED LIGHTS
     AND LH AND RH REMOTE

     DOOR MOUNTED MIRRORS               YES   NO   SPECIFY

     102 INCH EQUIPMENT WIDTH           YES   NO   SPECIFY

     LH AND RH 8 INCH BRIGHT FINISH     YES   NO   SPECIFY
     CONVEX MIRRORS MOUNTED UNDER
     PRIMARY MIRRORS

     STANDARD SIDE/REAR REFLECTORS      YES   NO   SPECIFY

     RH AFTERTREATMENT SYSTEM CAB       YES   NO   SPECIFY
     ACCESS WITH POLISHED DIAMOND
     PLATE COVER

     63X14 INCH TINTED REAR WINDOW      YES   NO   SPECIFY

     TINTED DOOR GLASS LH AND RH WITH   YES   NO   SPECIFY
     TINTED NON-OPERATING WING
     WINDOWS

     MANUAL DOOR WINDOW REGULATORS      YES   NO   SPECIFY

     TINTED WINDSHIELD                  YES   NO   SPECIFY

     2 GALLON WINDSHIELD WASHER         YES   NO   SPECIFY
     RESERVOIR WITHOUT FLUID LEVEL
     INDICATOR, FRAME MOUNTED

     OPAL GRAY VINYL INTERIOR           YES   NO   SPECIFY

     MOLDED PLASTIC DOOR PANEL          YES   NO   SPECIFY
     WITHOUT VINYL INSERT WITH
     ALUMINUM KICKPLATE LOWER DOOR

     MOLDED PLASTIC DOOR PANEL          YES   NO   SPECIFY
     WITHOUT VINYL INSERT WITH
     ALUMINUM KICKPLATE LOWER DOOR

     BLACK MATS WITH SINGLE INSULATION YES    NO   SPECIFY

     IN DASH STORAGE BIN                YES   NO   SPECIFY

     (2) CUP HOLDERS LH AND RH DASH     YES   NO   SPECIFY

Section A – Tender                                           Page A-20
GRAY/CHARCOAL FLAT DASH              YES    NO   SPECIFY

     SMART SWITCH EXPANSION MODULE        YES    NO   SPECIFY

     HEATER, DEFROSTER AND AIR            YES    NO   SPECIFY
     CONDITIONER
     STANDARD HVAC DUCTING                YES    NO   SPECIFY

     MAIN HVAC CONTROLS WITH              YES    NO   SPECIFY
     RECIRCULATION SWITCH

     STANDARD HEATER PLUMBING             YES    NO   SPECIFY

     VALEO HEAVY DUTY A/C REFRIGERANT YES        NO   SPECIFY
     COMPRESSOR

     BINARY CONTROL, R-134A               YES    NO   SPECIFY

     PREMIUM INSULATION                   YES    NO   SPECIFY

     SOLID-STATE CIRCUIT PROTECTION AND YES      NO   SPECIFY
     FUSES WITH SPARE FUSE KIT

     12V NEGATIVE GROUND ELECTRICAL       YES    NO   SPECIFY
     SYSTEM

     LH AND RH DOOR ACTIVATED DOME      YES      NO   SPECIFY
     LIGHTS, DUAL READING LIGHTS AND LH
     AND RH DOOR MOUNTED COURTESY
     LIGHTS

     CAB DOOR LATCHES WITH MANUAL         YES    NO   SPECIFY
     DOOR LOCKS

     (1) 12V POWER SUPPLY (1) DUAL 2.1 AMP YES   NO   SPECIFY
     USB CHARGER IN DASH

     BASIC HIGH BACK AIR SUSPENSION       YES    NO   SPECIFY
     DRIVER SEAT WITH MECHANICAL
     LUMBAR AND INTEGRATED CUSHION
     EXTENSION

     2 MAN TOOL BOX MID BACK NON          YES    NO   SPECIFY
     SUSPENSION PASSENGER SEAT WITH
     HEADRESTS

     LH AND RH INTEGRAL DOOR PANEL        YES    NO   SPECIFY
     ARMRESTS

Section A – Tender                                              Page A-21
VINYL WITH VINYL INSERT DRIVER SEAT YES     NO   SPECIFY

     VINYL WITH VINYL INSERT PASSENGER     YES   NO   SPECIFY
     SEAT

     HIGH VISIBILITY ORANGE SEAT BELTS     YES   NO   SPECIFY
     WITH DRIVER INDICATOR LIGHT AND
     AUDIBLE ALARM

     ADJUSTABLE TILT AND TELESCOPING       YES   NO   SPECIFY
     STEERING COLUMN

     4-SPOKE 18 INCH (450MM) STEERING      YES   NO   SPECIFY
     WHEEL

     DRIVER AND PASSENGER INTERIOR SUN YES       NO   SPECIFY
     VISORS

     INTERFACE CONNECTORS AND WIRING       YES   NO   SPECIFY
     FOR CUSTOMER PROVIDED LED STEP
     LIGHTING

     GRAY DRIVER INSTRUMENT PANEL          YES   NO   SPECIFY

     GRAY CENTER INSTRUMENT PANEL          YES   NO   SPECIFY

     BLACK GAUGE BEZELS                    YES   NO   SPECIFY

     LOW AIR PRESSURE INDICATOR LIGHT      YES   NO   SPECIFY
     AND AUDIBLE ALARM

     2 INCH PRIMARY AND SECONDARY AIR      YES   NO   SPECIFY
     PRESSURE GAUGES

     DASH MOUNTED AIR RESTRICTION          YES   NO   SPECIFY
     INDICATOR WITH GRADUATIONS

     97 DB BACKUP ALARM                    YES   NO   SPECIFY

     ELECTRONIC CRUISE CONTROL WITH        YES   NO   SPECIFY
     SWITCHES IN LH SWITCH PANEL

     KEY OPERATED IGNITION SWITCH AND      YES   NO   SPECIFY
     INTEGRAL START POSITION; 4 POSITION
     OFF/RUN/START/ACCESSORY

     ICU3S, 132X48 DISPLAY WITH            YES   NO   SPECIFY
     DIAGNOSTICS, 28 LED WARNING LAMPS
     AND DATA LINKED

Section A – Tender                                              Page A-22
HEAVY DUTY ONBOARD DIAGNOSTICS    YES    NO   SPECIFY
     INTERFACE CONNECTOR LOCATED
     BELOW LH DASH

     2 INCH ELECTRIC FUEL GAUGE        YES    NO   SPECIFY

     PROGRAMMABLE RPM CONTROL -        YES    NO   SPECIFY
     ELECTRONIC ENGINE

     ELECTRICAL ENGINE COOLANT         YES    NO   SPECIFY
     TEMPERATURE GAUGE

     2 INCH TRANSMISSION OIL           YES    NO   SPECIFY
     TEMPERATURE GAUGE

     ENGINE AND TRIP HOUR METERS       YES    NO   SPECIFY
     INTEGRAL WITHIN DRIVER DISPLAY

     CUSTOMER FURNISHED AND INSTALLED YES     NO   SPECIFY
     PTO CONTROLS

     ELECTRONIC STABILITY CONTROL      YES    NO   SPECIFY

     ELECTRIC ENGINE OIL PRESSURE GAUGE YES   NO   SPECIFY

     OVERHEAD INSTRUMENT PANEL         YES    NO   SPECIFY

     SMARTPLEX HUB MODULE WITH          YES   NO   SPECIFY
     OVERHEAD SWITCH MOUNTING, DRIVER
     SIDE AND CENTER CONSOLE (18 SWITCH
     SLOTS, NO CB)

     POWER AND GROUND STUDS IN/UNDER   YES    NO   SPECIFY
     DASH

     ELECTRONIC KPH SPEEDOMETER WITH   YES    NO   SPECIFY
     SECONDARY MPH SCALE, WITHOUT
     ODOMETER

     STANDARD VEHICLE SPEED SENSOR     YES    NO   SPECIFY

     ELECTRONIC 3000 RPM TACHOMETER    YES    NO   SPECIFY

     IGNITION SWITCH CONTROLLED ENGINE YES    NO   SPECIFY
     STOP

     10 ON/OFF LATCHING SMARTPLEX      YES    NO   SPECIFY
     SWITCHES

     BATTERY ON SMARTPLEX INDICATOR    YES    NO   SPECIFY
     LAMP
Section A – Tender                                           Page A-23
1-RED, 0-AMBER, 0-GREEN SMARTPLEX    YES   NO   SPECIFY
     INDICATOR LAMPS

     (2) OVERHEAD MOUNTED LANYARD         YES   NO   SPECIFY
     CONTROLS: (1) OFFICER AIR HORN AND
     (1) DRIVER AIR HORN

     DIGITAL VOLTAGE DISPLAY INTEGRAL     YES   NO   SPECIFY
     WITH DRIVER DISPLAY

     SINGLE ELECTRIC WINDSHIELD WIPER YES       NO   SPECIFY
     MOTOR WITH DELAY AND ARCTIC TYPE
     BLADES

     MARKER LIGHT SWITCH INTEGRAL WITH YES      NO   SPECIFY
     HEADLIGHT SWITCH

     ALTERNATING FLASHING LOW BEAM        YES   NO   SPECIFY
     HEADLAMPS WITH DASH SWITCH, WITH
     PARK BRAKE RELEASED

     ONE VALVE PARKING BRAKE SYSTEM       YES   NO   SPECIFY
     WITH DASH VALVE CONTROL
     AUTONEUTRAL AND WARNING
     INDICATOR

     SELF CANCELING TURN SIGNAL SWITCH YES      NO   SPECIFY
     WITH DIMMER, WASHER/WIPER AND
     HAZARD IN HANDLE

     INTEGRAL ELECTRONIC TURN SIGNAL      YES   NO   SPECIFY
     FLASHER WITH HAZARD LAMPS
     OVERRIDING STOP LAMPS

     PAINT SHALL BE WHITE HOOD AND CAB, YES     NO   SPECIFY
     AS SHOWN ON PAGES C7, C8, C9 OF THIS
     DOCUMENT
     BLACK, HIGH SOLIDS POLYURETHANE      YES   NO   SPECIFY
     CHASSIS PAINT

     STANDARD E COAT/UNDERCOATING         YES   NO   SPECIFY

     TWO (2) DIGITIZED MANUAL(S) SHALL BE YES   NO   SPECIFY
     PROVIDED ON OPERATION OF THE
     COMPLETE APPARATUS. THE
     MANUAL(S) SHALL INCLUDE A
     TROUBLESHOOTING GUIDE COMPLETE
     WITH RECOMMENDED DAILY, WEEKLY
     AND ANNUAL MAINTENANCE
     PROCEDURES

Section A – Tender                                             Page A-24
ALL CHASSIS, PUMPS AND MAJOR       YES   NO   SPECIFY
     COMPONENTS MUST BE
     MANUFACTURED IN NORTH AMERICA
     AND MUST BE ABLE TO SUPPLY PARTS
     FOR AN EMERGENCY VEHICLE WITHIN 48
     HOURS.

     THE MANUFACTURER OF THE           YES    NO   SPECIFY
     APPARATUS MUST BE FULLY OWNED
     AND MANAGED BY A PARENT COMPANY,
     CORPORATION, PARTNERSHIP, OR THAT
     IS A COMPANY 100% HELD IN NORTH
     AMERICA.

     THE BIDDER SHALL PROVIDE A "24    YES    NO   SPECIFY
     HOUR", "7-DAY PER WEEK" EMERGENCY
     PARTS AND SERVICE TOLL FREE
     TELEPHONE NUMBER. THIS PHONE
     NUMBER MUST BE LISTED ON A
     SEPARATE STATEMENT INCLUDED IN
     THE BID PACKAGE, ALONG WITH THE
     CONTACT NAME, BUSINESS NAME,
     ADDRESS, AND PHONE NUMBER OF THE
     LOCAL SERVICE AGENCY, WHICH WILL
     SERVICE THE VEHICLE AFTER BEING
     PLACED INTO SERVICE.

     THE SERVICE AGENCY SHALL BE       YES    NO   SPECIFY
     CAPABLE TO PERFORM ALL REQUIRED
     SERVICE WORK, AND SHALL ALSO HAVE
     AT THEIR DISPOSAL THE ABILITY TO
     HAVE ANY REQUIRED
     SUBCONTRACTING WORK, SUCH AS
     ENGINE, TRANSMISSION, ETC. WORK
     PERFORMED ON BEHALF OF THE
     APPARATUS MANUFACTURER.

     ENGINEERING DRAWINGS SHALL BE      YES   NO   SPECIFY
     SUBMITTED TO THE PURCHASER PRIOR
     TO COMMENCEMENT OF THE
     MANUFACTURING PROCESS.

     THIS DRAWING SHALL SHOW AT A       YES   NO   SPECIFY
     MINIMUM THE FRONT, LEFT, RIGHT AND
     REAR VIEWS OF THE VEHICLE, AS IT
     WILL LOOK AT THE TIME OF
     COMPLETION.

     A COPY OF THIS DRAWING SHALL BE    YES   NO   SPECIFY
     SIGNED AND RETURNED TO THE
     APPARATUS MANUFACTURER AND
     BECOME PART OF THE VEHICLE
     CONTRACT.

Section A – Tender                                           Page A-25
THE APPARATUS, PRIOR TO           YES     NO   SPECIFY
     ACCEPTANCE WILL BE REQUIRED TO
     MEET THE VEHICLE STABILITY OF THE
     APPLICABLE NFPA OR ULC AUTOMOTIVE
     FIRE APPARATUS STANDARD.

     A CALCULATED CENTER OF GRAVITY     YES    NO   SPECIFY
     SHALL BE PERFORMED TO ENSURE THE
     APPARATUS MEETS THESE
     REQUIREMENTS. THE CALCULATED
     CENTER OF GRAVITY SHALL BE NO
     HIGHER THAN 80 PERCENT OF THE REAR
     TRACK AXLE WIDTH.

     THE COMPLETED VEHICLE SHALL BE    YES     NO   SPECIFY
     TESTED AND LABELED TO CAN/ULC-
     S515-13 BY AN INDEPENDENT THIRD
     PARTY CERTIFICATION ORGANIZATION.

     THE THIRD PARTY ORGANIZATION       YES    NO   SPECIFY
     SHALL BE ACCREDITED FOR TESTING
     SYSTEMS ON FIRE APPARATUS IN
     ACCORDANCE WITH ISO/IEC 17020 OR
     ISO/IEC GUIDE 65.

     THE CERTIFICATION ORGANIZATION   YES      NO   SPECIFY
     SHALL NOT BE OWNED OR CONTROLLED
     BY MANUFACTURERS OR VENDORS OF
     THE APPARATUS BEING TESTED.

     APPROPRIATE FORMS OF DATA SHEETS YES      NO   SPECIFY
     SHALL BE PROVIDED AND USED DURING
     TESTING.

     THE COMPLETED VEHICLE SHALL        YES    NO   SPECIFY
     UNDERGO, PRIOR TO DELIVERY, A TWO
     (2) HOUR ROAD TEST WITH ALL
     APPLICABLE EMERGENCY EQUIPMENT
     ACTIVATED. A CERTIFICATION SHALL
     BE PROVIDED TO THE PURCHASER
     OUTLINING THE RESULTS OF THIS ROAD
     TEST.

     A WARNING LABEL SHALL BE PROVIDED YES     NO   SPECIFY
     IN THE CAB WITHIN SIGHT OF THE
     DRIVER STATING THE SEATING
     CAPACITY OF THE CAB/CREW CAB.

     ANOTHER WARNING LABEL SHALL BE      YES   NO   SPECIFY
     PROVIDED IN THE CAB WITHIN SIGHT OF
     THE DRIVER THAT THE OCCUPANTS
     MUST BE SEATED AND BELTED.

Section A – Tender                                            Page A-26
A WARNING LABEL SHALL BE PROVIDED YES    NO   SPECIFY
     IN THE CAB WITHIN SIGHT OF THE
     DRIVER STATING THE FOLLOWING
     APPARATUS DIMENSIONS:
     HEIGHT AND LENGTH IN STANDARD AND
     METRIC MEASUREMENTS.
     GROSS VEHICLE WEIGHT RATING IN
     POUNDS AND KILOGRAMS.

     THE WIRING AND PERMANENTLY        YES    NO   SPECIFY
     CONNECTED DEVICES AND EQUIPMENT
     SHALL BE SUBJECT TO A DIELECTRIC
     VOLTAGE WITHSTAND TEST OF 900
     VOLTS FOR ONE MINUTE. THE TESTING
     SHALL BE PERFORMED AFTER ALL BODY
     WORK HAS BEEN COMPLETED. THE
     ELECTRIC POLARITY OF ALL
     PERMANENTLY WIRED EQUIPMENT,
     CORD REELS, AND RECEPTACLES SHALL
     BE TESTED TO VERIFY THAT WIRING
     CONNECTIONS HAVE BEEN PROPERLY
     MADE.

     A PERMANENT LABEL SHALL BE        YES    NO   SPECIFY
     PROVIDED AND SHALL STATE THE TYPE
     AND QUANTITY OF THE FOLLOWING
     FLUIDS USED IN THE VEHICLE:
     ENGINE OIL
     ENGINE COOLANT
     CHASSIS TRANSMISSION FLUID
     DRIVE AXLE FLUID
     PUMP GEAR CASE
     PRIMER LUBRICANT (IF APPLICABLE)

     THERE SHALL BE TWO (2) ZICO HELMET YES   NO   SPECIFY
     HOLDERS SUPPLIED WITH THE
     APPARATUS. THE HELMET HOLDER
     SHALL COMPLY WITH THE 2009 EDITION
     OF NFPA 1901 FOR USE INSIDE OF CREW
     CABS. IT HOLDS BOTH TRADITIONAL
     AND CONTEMPORARY STYLE HELMETS
     WITHOUT ANY ADJUSTMENT NEEDED.

     THE CHASSIS WHEELS SHALL BE AN    YES    NO   SPECIFY
     ALUMINUM POLISHED FINISH FROM THE
     CHASSIS SUPPLIER.
     CHASSIS SUPPLIED HUB AND LUGNUT
     COVERS

Section A – Tender                                           Page A-27
TO MAINTAIN CHASSIS ENGINE         YES    NO   SPECIFY
     PERFORMANCE, THE CHASSIS EXHAUST
     SHALL BE MODIFIED MINIMALLY AFTER
     ANY EXHAUST TREATMENT DEVICES
     AND SHALL MEET THE CHASSIS
     SUPPLIER’S RECOMMENDATIONS. THE
     EXHAUST SHALL EXIT AT THE CURBSIDE
     OF THE APPARATUS BEFORE THE REAR
     AXLES AND SHALL BE A STRAIGHT
     EXHAUST PIPE DESIGN.

     WHERE THE CHASSIS EXHAUST PIPING    YES   NO   SPECIFY
     PASSES UNDER OR NEAR A BODY
     COMPARTMENT, THE EXHAUST PIPING
     SHALL BE SHIELDED UTILIZING A HEAT
     SHIELD MANUFACTURED FROM 1/8" 3003-
     H22 ALUMINUM CHECKER PLATE TO
     PREVENT COMPARTMENT EXPOSURE TO
     RADIANT HEAT.

     FOUR (4) HEAVY DUTY RUBBER REAR   YES     NO   SPECIFY
     MUD FLAPS SHALL BE PROVIDED AND
     INSTALLED ON THE APPARATUS. THE
     MUD FLAPS SHALL BE INSTALLED
     BEHIND THE FRONT AND REAR WHEELS.

     THE KEY UTILIZED FOR THE IGNITION YES     NO   SPECIFY
     SHALL BE SECURELY CHAINED TO
     EITHER THE STEERING COLUMN OR THE
     CAB DASH TO PREVENT LOSS OR
     REMOVAL OF THE IGNITION KEY.

     THERE SHALL BE .125" ALUMINUM      YES    NO   SPECIFY
     CHECKER PLATE TRIM INSTALLED AT
     THE CHASSIS STEPS. THE CHECKER
     PLATE SHALL BE EASILY REMOVABLE
     FOR EASE OF SERVICE AND
     MAINTENANCE IF REQUIRED.

     A KUSSMAUL PUMP PLUS1000 SERIES   YES     NO   SPECIFY
     MODEL #091-193-12, 40 AMP BATTERY
     CHARGER AND 10 AMP BATTERY SAVER
     SHALL BE INSTALLED.

Section A – Tender                                            Page A-28
THE BATTERY CHARGER SHALL SUPPLY YES          NO   SPECIFY
     A ‘SINGLE BATTERY BANK’ WITH
     AUTOMATIC OPERATION AND WITH AN
     ALUMINUM ENCLOSURE. THE SYSTEM
     SHALL HAVE A BUILT-IN SENSE CIRCUIT
     TO CHECK BATTERY VOLTAGE 120 TIMES
     A SECOND; THE SYSTEM SHALL
     COMPENSATE FOR VOLTAGE DROP IN
     CHARGING WIRES AND PROVIDE QUICK
     RECHARGING WITH NO OVER-CHARGING.
     THE UNIT SHALL INCLUDE FRONT PANEL
     CONNECTIONS FOR A REMOTE DISPLAY
     AND AUXILIARY LOADS.

     THE COMPRESSOR SHALL BE      A YES            NO   SPECIFY
     KUSSMAUL P/N 091-9-12V 12 VOLT
     COMPRESSOR.

     A KUSSMAUL SUPER AUTO EJECT MODEL YES         NO   SPECIFY
     #091-55-20-120, 20 AMP 120 VOLT SHORE
     POWER ASSEMBLY, COVER, SOLENOID
     INPUT WIRE, POWER CORD, AND PLUG
     SHALL BE INSTALLED.

     THE CHARGER SHALL INCLUDE A             YES   NO   SPECIFY
     MODEL #091-199-001 SINGLE BAR
     REMOTE DIGITAL DISPLAY.

     ONE (1) 2.5 LB. ABC VEHICLE TYPE FIRE   YES   NO   SPECIFY
     EXTINGUISHER WITH MOUNTING
     BRACKET

     ONE (1) STANDARD FIRST AID KIT SHALL YES      NO   SPECIFY
     BE PROVIDED.

     ONE (1) SET OF THREE (3) DUAL FACED     YES   NO   SPECIFY
     TRIANGULAR WARNING FLARES TO
     MEET THE DEPARTMENT OF
     TRANSPORTATION'S MOTOR VEHICLE
     SAFETY STANDARDS.

     EACH CAB STEP SHALL BE ILLUMINATED YES        NO   SPECIFY
     BY TECNIQ P/N E03 LED LIGHTS TO MEET
     THE REQUIREMENTS OF NFPA 1901.

     THERE SHALL BE A ONE INCH WIDE          YES   NO   SPECIFY
     REFLECTIVE STRIPE APPLIED TO THE
     FRONT OF THE APPARATUS. THE
     REFLECTIVE STRIPE SHALL BE A 3M
     SCOTCHLITE PRODUCT.

Section A – Tender                                                Page A-29
THERE SHALL BE REFLECTIVE STRIPING YES           NO   SPECIFY
     APPLIED TO THE INTERIOR CHASSIS CAB
     DOORS OF THE APPARATUS. THE
     REFLECTIVE STRIPE SHALL BE A 3M
     SCOTCHLITE PRODUCT.

     THE PUMP HOUSE SHALL BE A FULL             YES   NO   SPECIFY
     FRAME MODULE CONSTRUCTED FROM 2"
     X 2" X .188" AND 3" X 3" X .25" (6061-T6 /
     6063-T6) HEAVY-DUTY STRUCTURAL
     ALUMINUM EXTRUSIONS WHICH SHALL
     PROVIDE MAXIMUM STRENGTH AND
     DURABILITY.

     THE PUMP HOUSE SHALL BE ATTACHED YES             NO   SPECIFY
     TO THE CHASSIS FRAME WITH .25" THICK
     HEAVY-DUTY MOUNTING PLATES AND
     .5" GRADE 8 CADMIUM PLATED BOLTS
     WITH SELF-LOCKING NUTS. A
     TRANSITION BRACKET WITH RUBBER
     MOUNTS SHALL BE INSTALLED TO THE
     CHASSIS FRAME. THE PUMP HOUSE
     SHALL THEN BE MOUNTED TO THE
     RUBBER MOUNTS.

     THE FRONT AND REAR OF THE PUMP            YES    NO   SPECIFY
     HOUSE SHALL HAVE 1/8" 3003 H14 HI
     SHINE CHECKER PLATE TRIM.

     THE PUMP HOUSE INTERIOR SHALL BE   YES           NO   SPECIFY
     ACCESSIBLE BY AN INSPECTION DOOR
     ON THE RIGHT SIDE. THE INSPECTION
     DOOR SHALL BE CONSTRUCTED FROM
     .125" ALUMINUM HIGH SHINE CHECKER
     PLATE. THE DOOR SHALL BE FASTENED
     TO THE UPPER PORTION OF THE PUMP
     HOUSE WITH STAINLESS STEEL PIANO
     HINGES. THE LOCKING MECHANISMS
     FOR THE DOOR SHALL BE A SET OF TWO
     (2) LIFT AND TURN TWIST LOCK
     LATCHES.

     THE BOTTOM OF THE PUMP HOUSE              YES    NO   SPECIFY
     SHALL BE FITTED WITH A HEAT PAN.
     THE HEAT PAN SHALL ENCLOSE ALL
     SIDES, FRONT, AND REAR AND BOTTOM
     OF THE PUMP HOUSE.

     THE HEAT PAN VERTICAL SIDE WALLS          YES    NO   SPECIFY
     SHALL BE CONSTRUCTED FROM 1/8"
     5083-H321 SALT WATER GRADE SHEET
     ALUMINUM AND SHALL BE INSTALLED
     TO THE UNDERSIDE OF THE PUMP
     HOUSE.
Section A – Tender                                                   Page A-30
THERE SHALL BE DUAL 12 GAUGE 5052 YES     NO   SPECIFY
     H321 ALUMINUM PANELS THAT SHALL
     BE SPLIT IN THE CENTER AND
     REMOVABLE FOR ACCESS TO THE PUMP
     HOUSE COMPONENTS.

     ANY ADDITIONAL VERTICAL           YES     NO   SPECIFY
     ENCLOSURE TO PROPERLY ENCLOSE THE
     HEAT PAN AROUND CHASSIS
     COMPONENTS SHALL BE WITH 12 GAUGE
     5052 H321 ALUMINUM.

     THE PUMP OPERATOR'S PANEL AND THE YES     NO   SPECIFY
     RIGHT SIDE PUMP PANEL SHALL BE
     CONSTRUCTED FROM 1/8" ALUMINUM
     WITH A BLACK VINYL ANTI-GLARE
     COATING. BOTH THE RIGHT SIDE AND
     LEFT SIDE PUMP PANELS SHALL BE
     BOLTED TO THE PUMP HOUSE FOR EASE
     OF REMOVAL.

     THE PUMP OPERATOR'S PANEL SHALL BE YES    NO   SPECIFY
     MANUFACTURED IN A TWO-TIER
     DESIGN.

     THE BOTTOM/LOWER TIER (PORTION)    YES    NO   SPECIFY
     SHALL BE SCREWED INTO PLACE AND
     CAN BE REMOVABLE FOR SERVICING.
     THE LOWER LEVEL CONTAINS ALL THE
     VALVE CONTROLS, DISCHARGES,
     SUCTIONS, DRAINS, ETC. ALL SUCTION
     AND DISCHARGE PORTS EXITING
     THROUGH THE PANELS SHALL BE LASER
     CUT TO PROVIDE A SMOOTH EXACT FIT.
     NO COVER OVERLAY PLATES SHALL BE
     USED.

     THE TOP TIER (PORTION) OF THE PANEL YES   NO   SPECIFY
     SHALL BE BOTTOM HINGED WITH A
     STAINLESS STEEL PIANO HINGE AND
     SHALL HAVE TWO (2) LIFT AND TURN
     TWIST LOCK LATCHES LOCATED AT THE
     TOP OF THE PANEL FOR PUMP AND
     GAUGE SERVICING. THIS PANEL SHALL
     CONTAIN ALL GAUGES AND
     MONITORING INSTRUMENTS.

     ALL GAUGES AND CONTROLS SHALL BE YES      NO   SPECIFY
     SYMMETRICALLY AND LOGICALLY LAID
     OUT TO EASILY ENABLE THE PUMP
     OPERATOR TO MONITOR ALL ASPECTS
     OF PUMP OPERATION.

Section A – Tender                                            Page A-31
ALL VALVE CONTROLS SHALL BE MADE YES      NO   SPECIFY
     BY USE OF HEAVY-DUTY STEEL RODS,
     PIVOTS, AND CLASS I OPERATORS.

     AUXILIARY SUCTION VALVE CONTROLS YES      NO   SPECIFY
     SHALL BE LEVER CONTROLLED
     ADJACENT TO THE SUCTION SWIVEL.
     THE AUXILIARY SUCTION VALVE SHALL
     BE INSTALLED BEHIND THE PUMP
     PANEL.

     THE PUMP HOUSE INTERIOR SHALL BE   YES    NO   SPECIFY
     ACCESSIBLE BY AN INSPECTION DOOR
     ON THE RIGHT SIDE. THE INSPECTION
     DOOR SHALL BE CONSTRUCTED FROM
     .125" ALUMINUM HIGH SHINE CHECKER
     PLATE. THE DOOR SHALL BE FASTENED
     TO THE UPPER PORTION OF THE PUMP
     HOUSE WITH STAINLESS STEEL PIANO
     HINGES. THE LOCKING MECHANISMS
     FOR THE DOOR SHALL BE A SET OF TWO
     (2) LIFT AND TURN TWIST LOCK
     LATCHES.

     THE PUMP OPERATOR PANEL SHALL       YES   NO   SPECIFY
     COME WITH CLASS 1 P/N 121384 VACUUM
     AND PRESSURE TESTING PORT.

     A CLASS 1 P/N 105120 BRASS ASSEMBLY YES   NO   SPECIFY
     WITH CHROME PLATED ZINC HANDLE
     PETCOCK CONTROL VALVE SHALL BE
     MOUNTED AT THE PUMP OPERATOR
     PANEL TO ALLOW TANK WATER TO
     RECIRCULATE THRU THE PUMP. THE
     PORT SIZE AND PLUMBING SHALL BE 1/4"

     THERE SHALL BE AN AUXILIARY HEAT   YES    NO   SPECIFY
     EXCHANGER MOUNTED ON THE
     CHASSIS. THE HEAT EXCHANGER WILL
     ALLOW TANK WATER TO COOL THE
     CHASSIS ENGINE.

     TWO (2) CROSS LAY HOSE BEDS SHALL  YES    NO   SPECIFY
     BE PROVIDED AND INSTALLED
     TRANSVERSELY ABOVE THE PUMP
     HOUSE AND SHALL HAVE VINYL HOSE
     MATTING FLOORING TO ALLOW FOR
     WATER DRAINAGE AND AIR MOVEMENT
     UNDER THE HOSE. A 3/16" ALUMINUM
     DIVIDER SHALL SEPARATE THE HOSE
     BEDS. EACH HOSE BED SHALL BE SIZED
     TO HOLD 200' OF 1 3/4" HOSE.

Section A – Tender                                            Page A-32
THE PLUMBING ON THE 1.5"            YES   NO   SPECIFY
     DISCHARGE(S) SHALL BE 2" DIAMETER
     HEAVY DUTY PIPING WITH VICTAULIC
     AND CLASS 1 SBR SYNTHETIC RUBBER
     HOSE WITH STAINLESS STEEL
     COUPLINGS. EACH DISCHARGE SHALL
     BE EQUIPPED WITH A 90 DEGREE SWIVEL
     WITH 1.5" MALE THREADED COUPLINGS
     TO ALLOW THEM TO BE USED FROM
     EITHER SIDE OF THE APPARATUS.

     A 2.5" DISCHARGE GAUGES SHALL BE   YES    NO   SPECIFY
     MOUNTED ADJACENT TO THE
     DISCHARGE VALVE CONTROL HANDLE.
     A COLOR CODED TRIM RING MEETING
     NFPA'S REQUIREMENTS FOR COLOR
     CODING SHALL BE SUPPLIED.

     THE GAUGE SHALL BE FULLY FILLED   YES     NO   SPECIFY
     WITH PULSE AND VIBRATION
     DAMPENING INTERLUBE TO LUBRICATE
     THE INTERNAL MECHANISMS TO
     PREVENT LENS CONDENSATION AND TO
     ENSURE PROPER OPERATION.
     TO PREVENT INTERNAL FREEZING AND
     TO KEEP CONTAMINANTS FROM
     ENTERING THE GAUGE, THE STEM AND
     BOURDON TUBE SHALL BE FILLED WITH
     LOW TEMPERATURE OIL AND BE SEALED
     FROM THE WATER SYSTEM USING AN
     ISOLATING DIAPHRAGM LOCATED IN
     THE STEM

     THE GAUGES SHALL BE IN DUAL SCALE YES     NO   SPECIFY
     AND MEASURE IN INCREMENTS OF 0-400
     PSI AND 0-2800 KPA.

     ALL 1.5" THREAD TYPES SHALL BE     YES    NO   SPECIFY
     NPSH.

Section A – Tender                                            Page A-33
THE VALVE SHALL BE AKRON BRASS     YES   NO   SPECIFY
     STYLE 8820 SWING-OUT™ VALVES. THE
     VALVE SHALL HAVE AN ALL BRASS
     BODY WITH FLOW OPTIMIZING
     STAINLESS STEEL BALL AND DUAL
     POLYMER SEATS. THE VALVE SHALL BE
     CAPABLE OF DUAL DIRECTIONAL FLOW
     WHILE INCORPORATING A SELF-
     LOCKING BALL FEATURE USING AN
     AUTOMATIC FRICTION LOCK DESIGN
     AND SPECIALLY DESIGNED FLOW
     OPTIMIZING STAINLESS STEEL BALL.
     ALL STAINLESS STEEL PARTS MUST BE
     316 GRADE FOR INCREASED RESISTANCE
     TO CORROSION. THE VALVE SHALL NOT
     REQUIRE LUBRICATION OF SEATS OR
     ANY OTHER INTERNAL WATERWAY
     PARTS, AND MUST BE CAPABLE OF
     SWINGING OUT OF THE WATERWAY FOR
     MAINTENANCE BY THE REMOVAL OF SIX
     BOLTS. PRODUCT MUST CARRY A 10
     YEAR MANUFACTURER’S WARRANTY.

     THE VALVES SHALL HAVE CHROME T     YES   NO   SPECIFY
     HANDLE ACTUATORS. FOR CHEMICAL
     AND WEAR RESISTANCE A LAMACOID
     LABEL SPECIFYING THE DISCHARGE
     SHALL BE INSET INTO THE T HANDLE
     ACTUATOR. THE LABEL SHALL BE
     COLOR CODED AS PER NFPA 1901
     REQUIREMENTS.

     A DRAIN SHALL BE INSTALLED AT THE YES    NO   SPECIFY
     PUMP PANEL. THE DRAIN SHALL HAVE
     3/4" SYNFLEX DRAIN LINES TIED TO A 1/4
     TURN DRAIN VALVE WITH HIGH
     PRESSURE BRASS FITTINGS.

     A HEAVY DUTY VINYL TARP COVER      YES   NO   SPECIFY
     SHALL BE PROVIDED OVER THE CROSS
     LAY COMPARTMENTS AND HELD IN
     POSITION WITH A COMBINATION OF
     SHOCK CORD FASTENER AND 1/4 TURN
     FASTENERS. THE VINYL TARP SHALL BE
     RED IN COLOUR.

     THERE SHALL BE A RUBBER FOAM CELL YES    NO   SPECIFY
     PERMANENTLY MOUNTED BETWEEN
     THE PUMP HOUSE AND THE BODY FOR
     MAXIMUM PUMP HOUSE HEAT
     RETENTION. THE SEAL SHALL BE
     MOUNTED VERTICALLY DOWN THE
     HEIGHT OF THE PUMP HOUSE, ONE EACH
     SIDE.
Section A – Tender                                           Page A-34
THREE INCH "C" CHANNEL ALUMINUM       YES    NO   SPECIFY
     RUB RAILS SHALL BE BOLTED INTO
     PLACE WITH NYLON SPACERS ON THE
     LOWER FRAMEWORK ON THE PUMP
     HOUSE RUNNING BOARDS. THE RUB
     RAIL WILL EXTEND TO THE OUTSIDE
     EDGES OF THE RUNNING BOARDS FOR
     PROTECTION FROM IMPACT DAMAGE

     THE TOP SURFACE OF THE RUB RAIL     YES      NO   SPECIFY
     SHALL HAVE A NON-SLIP SURFACE
     MEETING THE REQUIREMENTS OF NFPA
     1901 FOR NON SLIP WALKING SURFACES.

     TWO (2) DTAC 210-12 16,000 BTU FORCED YES    NO   SPECIFY
     AIR COOLANT HEATERS SHALL BE
     INSTALLED.
     THE HEATERS SHALL BE MOUNTED LOW
     IN THE PUMP HOUSE SO THAT THE HEAT
     WILL BE DISTRIBUTED EVENLY IN THE
     PUMP HOUSE AND WILL KEEP THE
     DRAIN LINES OPEN. AN ON/OFF
     ILLUMINATED ROCKER SWITCH SHALL
     BE MOUNTED ON THE PUMP PANEL FOR
     OPERATION OF THE HEATERS.

     THERE SHALL BE A TOTAL OF FOUR (4)  YES      NO   SPECIFY
     6.5" X 3" TECNIQ E10 CLEAR LED DOME
     LIGHTS, (TWO (2) EACH SIDE) TO
     ADEQUATELY ILLUMINATE THE SIDE
     PUMP PANELS. THE LIGHTS SHALL BE
     MOUNTED UNDER A PROTECTIVE HOOD
     OF THE SAME MATERIAL AS THE SIDE
     PUMP PANELS. THE LIGHTS SHALL BE
     ACTIVATED BY A SWITCH AT THE PUMP
     OPERATOR PANEL.

     THE INTERIOR OF THE PUMP HOUSE         YES   NO   SPECIFY
     SHALL BE ILLUMINATED BY A TOTAL OF
     TWO (2) 6.5" X 3" TECNIQ E10 CLEAR LED
     DOME LIGHTS. ONE (1) EACH SIDE. THE
     LIGHTS SHALL BE ACTIVATED BY A
     SWITCH AT THE PUMP OPERATOR
     PANEL.

Section A – Tender                                               Page A-35
FIRE RESEARCH PUMPBOSS SERIES YES       NO   SPECIFY
     PBA400-A00 PRESSURE GOVERNOR AND
     MONITORING DISPLAY KIT SHALL BE
     INSTALLED. THE KIT SHALL INCLUDE A
     CONTROL MODULE, INTAKE PRESSURE
     SENSOR, DISCHARGE PRESSURE SENSOR,
     AND CABLES. THE CONTROL MODULE
     CASE SHALL BE WATERPROOF AND HAVE
     DIMENSIONS NOT TO EXCEED 6 3/4" HIGH
     BY 4 5/8". THE CONTROL KNOB SHALL BE
     2" IN DIAMETER WITH NO MECHANICAL
     STOPS, HAVE A SERRATED GRIP, AND A
     RED IDLE PUSH BUTTON IN THE CENTER.
     IT SHALL NOT EXTEND MORE THAN 1 3/4"
     FROM THE FRONT OF THE CONTROL
     MODULE. INPUTS FOR MONITORED
     ENGINE INFORMATION SHALL BE FROM A
     J1939 DATA BUS OR INDEPENDENT
     SENSORS.     OUTPUTS    FOR   ENGINE
     CONTROL SHALL BE ON THE J1939 DATA
     BUS OR ENGINE SPECIFIC WIRING. INPUTS
     FROM THE PUMP DISCHARGE AND
     INTAKE PRESSURE SENSORS SHALL BE
     ELECTRICAL.

     THE FOLLOWING CONTINUOUS DISPLAYS YES   NO   SPECIFY
     SHALL BE PROVIDED:
     -ENGINE RPM; SHOWN WITH FOUR
     DAYLIGHT BRIGHT LED DIGITS MORE
     THAN 1/2" HIGH
     -CHECK ENGINE AND STOP ENGINE
     WARNING LEDS
     -ENGINE OIL PRESSURE; SHOWN ON A
     DUAL COLOR (GREEN/RED) LED BAR
     GRAPH DISPLAY
     -ENGINE    COOLANT    TEMPERATURE;
     SHOWN ON A DUAL COLOR (GREEN/RED)
     LED BAR GRAPH DISPLAY
     -TRANSMISSION TEMPERATURE: SHOWN
     ON A DUAL COLOR (GREEN/RED) LED BAR
     GRAPH DISPLAY
     -BATTERY VOLTAGE; SHOWN ON A DUAL
     COLOR (GREEN/RED) LED BAR GRAPH
     DISPLAY
     -PRESSURE AND RPM OPERATING MODE
     LEDS
     -PRESSURE / RPM SETTING; SHOWN ON A
     DOT MATRIX MESSAGE DISPLAY
     -THROTTLE READY LED.

Section A – Tender                                          Page A-36
A DOT-MATRIX MESSAGE DISPLAY YES      NO   SPECIFY
     SHALL    SHOW     DIAGNOSTIC    AND
     WARNING MESSAGES AS THEY OCCUR. IT
     SHALL SHOW MONITORED APPARATUS
     INFORMATION, STORED DATA, AND
     PROGRAM OPTIONS WHEN SELECTED BY
     THE OPERATOR. ALL LED INTENSITY
     SHALL BE AUTOMATICALLY ADJUSTED
     FOR DAY AND NIGHT TIME OPERATION.
     THE PROGRAM SHALL STORE THE
     ACCUMULATED OPERATING HOURS FOR
     THE PUMP AND ENGINE TO BE
     DISPLAYED WITH THE PUSH OF A
     BUTTON. IT SHALL MONITOR INPUTS AND
     SUPPORT     AUDIBLE   AND    VISUAL
     WARNING ALARMS FOR THE FOLLOWING
     CONDITIONS:
     -HIGH BATTERY VOLTAGE
     -LOW BATTERY VOLTAGE (ENGINE OFF)
     -LOW BATTERY VOLTAGE (ENGINE
     RUNNING)
     -HIGH TRANSMISSION TEMPERATURE
     -LOW ENGINE OIL PRESSURE
     -HIGH ENGINE COOLANT TEMPERATURE
     -OUT OF WATER (VISUAL ALARM ONLY)
     -NO ENGINE RESPONSE (VISUAL ALARM
     ONLY).

     THE PROGRAM FEATURES SHALL BE YES     NO   SPECIFY
     ACCESSED VIA PUSH BUTTONS LOCATED
     ON THE FRONT OF THE CONTROL
     MODULE. THERE SHALL BE A USB PORT
     LOCATED AT THE REAR OF THE CONTROL
     MODULE TO UPLOAD FUTURE FIRMWARE
     ENHANCEMENTS.

Section A – Tender                                        Page A-37
THE GOVERNOR SHALL OPERATE IN TWO YES    NO   SPECIFY
     CONTROL MODES, PRESSURE AND RPM.
     NO DISCHARGE PRESSURE OR ENGINE
     RPM VARIATION SHALL OCCUR WHEN
     SWITCHING    BETWEEN      MODES.   A
     THROTTLE READY LED SHALL LIGHT
     WHEN THE INTERLOCK SIGNAL IS
     RECOGNIZED. THE GOVERNOR SHALL
     START IN PRESSURE MODE AND SET THE
     ENGINE RPM TO IDLE. IN PRESSURE MODE
     THE         GOVERNOR           SHALL
     AUTOMATICALLY       REGULATE     THE
     DISCHARGE PRESSURE AT THE LEVEL
     SET BY THE OPERATOR. IN RPM MODE
     THE GOVERNOR SHALL MAINTAIN THE
     ENGINE RPM AT THE LEVEL SET BY THE
     OPERATOR EXCEPT IN THE EVENT OF A
     DISCHARGE PRESSURE INCREASE. THE
     GOVERNOR SHALL LIMIT A DISCHARGE
     PRESSURE INCREASE IN RPM MODE TO A
     MAXIMUM OF 30 PSI. OTHER SAFETY
     FEATURES        SHALL        INCLUDE
     RECOGNITION      OF     NO     WATER
     CONDITIONS WITH AN AUTOMATIC
     PROGRAMMED RESPONSE AND A PUSH
     BUTTON TO RETURN THE ENGINE TO
     IDLE.

     THE    PRESSURE    GOVERNOR   AND YES    NO   SPECIFY
     MONITORING PRESSURE DISPLAY SHALL
     BE PROGRAMMED AT INSTALLATION FOR
     A SPECIFIC ENGINE.

     TWO (2) 4.5" MASTER PUMP GAUGES    YES   NO   SPECIFY
     SHALL BE SUPPLIED AND MOUNTED IN
     CLOSE PROXIMITY TO THE THROTTLE,
     PRIMER, AND ENGINE
     INSTRUMENTATION. THE INTAKE GAUGE
     SHALL BE TO THE LEFT OF THE
     DISCHARGE GAUGE. BRIGHT METAL
     TRIM RINGS SHALL BE SUPPLIED WITH
     EACH GAUGE. THE GAUGES SHALL BE IN
     DUAL SCALE AND MEASURE IN
     INCREMENTS OF 0-400 PSI AND 0-2800
     KPA.

Section A – Tender                                           Page A-38
GAUGES SHALL BE FULLY FILLED WITH YES     NO   SPECIFY
     PULSE AND VIBRATION DAMPENING
     INTER LUBE TO LUBRICATE THE
     INTERNAL MECHANISMS TO PREVENT
     LENS CONDENSATION AND TO ENSURE
     PROPER OPERATION. THE ZYTEL NYLON
     CASES SHALL BE TEMPERATURE
     COMPENSATED WITH AN INTERNAL
     BREATHING DIAPHRAGM TO PERMIT
     FULLY FILLED CASES AND TO ALLOW A
     RIGID LENS WITH A DISTORTION FREE
     VIEWING AREA.

     TO PREVENT INTERNAL FREEZING AND YES      NO   SPECIFY
     TO KEEP CONTAMINANTS FROM
     ENTERING THE GAUGE, THE STEM AND
     BOURDON TUBE SHALL BE FILLED WITH
     LOW TEMPERATURE OIL AND BE SEALED
     FROM THE WATER SYSTEM USING AN
     ISOLATING DIAPHRAGM LOCATED IN
     THE STEM

     FIRE RESEARCH TANKVISION PRO MODEL YES    NO   SPECIFY
     WLA300-A00 TANK INDICATOR KIT SHALL
     BE INSTALLED. THE KIT SHALL INCLUDE
     AN ELECTRONIC INDICATOR MODULE, A
     PRESSURE SENSOR, AND A 10' SENSOR
     CABLE. THE INDICATOR SHALL SHOW
     THE VOLUME OF WATER IN THE TANK ON
     NINE (9) EASY TO SEE SUPER BRIGHT RGB
     LEDS. A WIDE VIEW LENS OVER THE LEDS
     SHALL PROVIDE FOR A VIEWING ANGLE
     OF 180 DEGREES. THE INDICATOR CASE
     SHALL          BE        WATERPROOF,
     MANUFACTURED                       OF
     POLYCARBONATE/NYLON         MATERIAL,
     AND HAVE A DISTINCTIVE BLUE LABEL.

     THE PUMP SHALL BE A DARLEY PUMP,    YES   NO   SPECIFY
     MODEL PSM 1250. THE PUMP SHALL BE
     RATED AT:
     1250 gpm (4731 L/M) @150psi
     875 gpm (2646 L/M) @200 psi
     625 gpm (2365 L/M) @ 250 psi

Section A – Tender                                            Page A-39
VERTICALLY SPLIT TYPE. FINE GRAIN YES      NO   SPECIFY
     ALLOY CAST IRON, BRONZE FITTED. A
     CORED HEATING JACKET THAT USES
     ENGINE COOLANT PROTECTS THE PUMP
     FROM FREEZING IN WINTER WEATHER.

     HIGH STRENGTH BRONZE ALLOY,          YES   NO   SPECIFY
     ACCURATELY BALANCED AND
     SPLINED TO PUMP SHAFT FOR
     PRECISION FIT AND DURABILITY.

     RENEWABLE DOUBLE LABYRINTH TYPE YES        NO   SPECIFY
     BRONZE SEAL RINGS AS STANDARD

     PUMP SHAFT PRECISION GROUND         YES    NO   SPECIFY
     STAINLESS STEEL WITH LONG WEARING
     CERAMIC HARD COATING UNDER THE
     PACKING GLAND. THE SHAFT IS SPLINED
     FOR THE BROACHED IMPELLER HUBS
     FOR GREATER RESISTANCE TO WEAR,
     TORSIONAL VIBRATION, AND TORQUE
     IMPOSED BY THE ENGINE.

     PUMP SHALL BE ALLOY CAST IRON WITH YES     NO   SPECIFY
     ADEQUATE OIL RESERVE CAPACITY FOR
     LOW OPERATING TEMPERATURE.

     PUMP DRIVE SHAFT SHALL BE            YES   NO   SPECIFY
     PRECISION GROUND, HEAT TREATED
     ALLOY STEEL WITH 2.5“-10 SPLINE
     STANDARD INPUT AND OUTPUT. DRIVE
     SHAFTS SHALL BE SUPPLIED WITH
     SPICER END YOKES.

     PUMP GEARS SHALL BE 3” FACE          YES   NO   SPECIFY
     HELICAL. PRECISION CUT FROM
     HEAT TREATED STEEL FOR QUIET
     OPERATION AND LONG LIFE.

     PUMP GEAR SHIFT 3.5" FACE HELICAL.   YES   NO   SPECIFY
     PRECISION CUT FROM HEAT TREATED
     ALLOY STEEL SPLINED SPUR GEAR
     ENGAGES EITHER PUMP DRIVE OR
     TRUCK DRIVE SHAFT GEAR.

Section A – Tender                                             Page A-40