PLANNING COMMISSION MEETING Thursday June 03, 2021 Public Meeting - Farmington City Hall 160 S. Main Street, Farmington, Utah. Study Session: 6:00 p.m. Quarterly Training Regular Session: 7:00 p.m. Farmington City Planning Commission meetings, including this meeting, are open to the public. If you wish to view the regular session online, the link to the live hearings and to comment electronically can be found on the Farmington City website at www.farmington.utah.gov. If you wish to email a comment for any of the listed public hearings, you may do so at crowe@farmington.utah.gov by 5 p.m. on the day listed above. 1. City Council Report SUBDIVISION APPLICATION 2. Symphony Homes – Applicant is requesting preliminary plat approval for the Chestnut Farms Phase 5 Planned Unit Development (PUD) subdivision, located on 7.34 acres, at approximately 475 S 1350 W in the AE (Agricultural Estates) zone. (S-5-20) 3. Forza Terra LLC – Applicant is requesting final plat approval for the Mountain View Phase 2 Planned Unit Development (PUD) subdivision, located on 4.35 acres, at approximately 111 S 650 W in the R (Residential) zone. (S-3-21) CONDITIONAL USE APPLICATION 4. Matt Frost – Applicant is requesting approval for a conditional use permit to build an accessory dwelling unit (ADU) on the property located at 753 Glovers Ln., in the A (Agricultural) zone. (C-5-21) ZONE TEXT AMENDMENT 5. Farmington City (Public Hearing) – Applicant is requesting consideration of amendments to the Zoning Ordinance to require developers/owners of any new dwelling units to set aside a certain percentage of their developments as affordable housing, or to pay a fee in lieu, or some other benefit, and to consider additional affordable housing amendments to the Zoning Ordinance (ZT-1-21) OTHER BUSINESS 6. Miscellaneous, correspondence, etc. a. The Everly (PMP-5-20) Discussion only b. Other Please Note: Planning Commission applications may be tabled by the Commission if: 1. Additional information is needed in order to take action on the item; OR 2. If the Planning Commission feels, there are unresolved issues that may need additional attention before the Commission is ready to make a motion. No agenda item will begin after 10:00 p.m. without a unanimous vote of the Commissioners. The Commission may carry over Agenda items, scheduled late in the evening and not heard to the next regularly scheduled meeting. Posted May 28, 2021 Carly Rowe, Planning/Recording Secretary
Planning Commission Staff Report June 3, 2021 ______________________________________________________________________________ Item 3: Preliminary Plat – Chestnut Farms Phase 5 PUD Public Hearing: No Application No.: S-5-20 Property Address: Approximately 475 S 1350 W General Plan Designation: RRD (Rural Residential Density) Zoning Designation: AE (PUD) Area: 10.27 acres Number of Lots: 25 Property Owner: Symphony Homes LLC Applicant: Jared Schmidt Request: Applicant is seeking preliminary plat approval for Chestnut Phase 5 PUD. ______________________________________________________________________________ Suggested Motion Move the Planning Commission approve the Chestnut Farms Phase 5 PUD preliminary plat, subject to all applicable Farmington City ordinances and development standards. With the condition that the preliminary plat follows the Preliminary (PUD) Master Plan and schematic subdivision plan. Findings for Approval: 1. The schematic subdivision plan, rezone, preliminary PUD Master plan and amendment were approved by the City Council on April 6, 2021. The proposed preliminary plat meets applicable City ordinances and is consistent with prior approvals. Supplemental Information 1. Vicinity Map 2. Preliminary plat 1
1 275W e D riv ewa y st 5 2 o 0S 0 3 o 0Suth 1 350W est 5 12 e 5Wst 4 75S outh 5 12 e 5Wst D iscla im e r: Th is m a pw as p ro du cedb yF arm in gto nC ity 0 1 50 3 00 4 50 6 00 G ISa n dis fo r re fere nceo n ly . VICINITY MAP F e e t T th a h ein is m ccu ra fo a rm a p is b te a tio n nco elie d su v n e ta ita inedo d to b b le fo n e r lim itedu se s. F arm in g to nC ity Chestnut Farms Phase 3, 5, 6 M ete rs m a a ccu k esn ra ow cy o arra f th n ty a e in s toth fo rmatio e n D ate :7/2 2/2 020 0 2 5 5 0 7 5 1 00 co p u n rp ta o in se ed fo s. r a ny o th er
& Associates, Inc Reeve & Associates, Inc. - Solutions You Can Build On Reev Reeve & Associates, Inc. - Solutions You Can Build On Reeve & Associates, Inc. - Solutions You Can Build On · · · Chestnut Farms PUD - Phase 5 Farmington City, Davis County, Utah Reeve & Associates, Inc. - Solutions You Can Build On
& Associates, Inc Reeve & Associates, Inc. - Solutions You Can Build On Reev Reeve & Associates, Inc. - Solutions You Can Build On Reeve & Associates, Inc. - Solutions You Can Build On Chestnut Farms PUD - Phase 5 Farmington City, Davis County, Utah Reeve & Associates, Inc. - Solutions You Can Build On
Planning Commission Staff Report June 3, 2021 ______________________________________________________________________________ Item 3: Final Plat — Mountain View Phase 2 Subdivision Public Hearing: No Application No.: S-3-21 Property Address: 200 South 650 West General Plan Designation: AG (Agricultural Preservation) and RRD (Rural Residential Density) Zoning Designation: R Area: 5.81 Number of Lots: 16 Property Owner: Forza Terra, LLC. Agent: Shane Smoot Request: The applicant is seeking final plat approval for Mountain View Phase 2 Subdivision. ______________________________________________________________________________ Background Information The Final Plat for Mountain View Phase 2 Subdivision is a modification of the Mountain View Phase 2 Subdivision, approved by the Planning Commission on April 4, 2020. The amendment to the Preliminary Master Plan, rezone and subdivision schematic plan update were recommended for approval on March 4, 2021. The City Council approved the same on April 6, 2021. The update and master plan amendment approved on that day, shifted and changed the lot sizes in the phase to accommodate the newly acquired section of Parcel 08-087-0089. There are a few key differences in the approved plan and the modification: 1. The Parcel formerly known as “A” will now be Lot 206. 2. New Lot 206 modifies former Parcel A by adding an open space parcel connecting the cul- de-sac to the Legacy Trail. 3. Lot 211 (as on the final plat), will be Lot 215. And a small section of open space has been added on the western border. The City has recommended removing this parcel, as it does not serve a purpose, and is not necessary to meet the City’s open space standards. 4. A 0.411 acre of open space has been added bordering 250 South, where there is currently a trailhead to the Legacy Trail. The applicant would maintain and update this trailhead as part of the subdivision’s open space requirements. The applicant is going through the subdivision process again as a requirement of City ordinance, and the major changes from the original approval to the current application. 1
Suggested Motion Move the Planning Commission approve the final plat for Mountain View Phase 2 Subdivision. All subject to all applicable Farmington City ordinances and development standards and any remaining DRC comments, and the following conditions: 1. The applicant applies any conditions of Schematic Subdivision update, rezone, and Preliminary Master Plan amendment approval. 2. Any conditions of the previous Final Plat approval for Mountain View Phase 3 shall also apply. Findings for Approval: 1. The modification is a better use of land than the previous Final Plat. 2. The Subdivision Schematic Plan and Rezone fit the General Plan designation and the current character of the area. 3. The Mountain View Subdivision is within walking distance from the commuter rail stop. 4. The modification creates a new open space parcel on the northwest side of Lot 206. 5. The applicant has agreed to maintain and update the trailhead to Legacy Trail on the south side of the subdivision as open space. Supplemental Information 1. Vicinity Map 2. Final Plat 2
ghw ay ay 08-087-0015 08-087-0027 89 State Street 08-075-0074 08-087-0010 08-087-0028 77 S 601 W 08-087-0097 08-087-0030 08-087-0098 08-076-0120 111 S 08-087-0089 Lega 08-087-0138 c 121 S 86 S 08-087-0185 08-087-0184 08-087-0029 97 S 92 S 650 West Lega 08-076-0119 cy Pa 08-087-0131 08-087-0130 113 S rkwa 106 S 08-087-0186 y So 594 W 584 W 570 W uthb 129 S ound 08-087-0174 135 S 08-629-0119 08-087-0175 593 W 583 W 573 W 565 W 134 S 153 S 08-087-0187 149 S 08-076-0116 08-629-0102 08-629-0118 152 S 08-629-0117 167 S 08-087-0033 161 S 564 W 08-629-0101 548 W 179 S 08-629-0116 547 W 08-629-0120 182 S 08-629-0103 187 S 08-629-0104 08-629-0115 563 W 191 S 08-087-0039 08-629-0114 08-629-0107 199 S 08-629-0106 08-629-0105 08-629-0113 0 50 100 150 200 VICINITY MAP Feet Mountain View Phase 2 Meters Date: 3/1/2021 0 10 20 30 40
Reeve & Associates, Inc. - Solutions You Can Build On Reeve & Associates, Inc. - Solutions You Can Build On Reeve & Associates, Inc. - Solutions You Can Build On Reeve & Associates, Inc. Reeve & Associates, Inc. - Solutions You Can Build On
Planning Commission Staff Report June 3, 2021 ______________________________________________________________________________ Item 4: Conditional Use – Frost Accessory Dwelling Unit (ADU) Public Hearing: No Application No.: C-5-21 Property Address: 753 West Glovers Lane General Plan Designation: RRD (Rural Residential Density) Zoning Designation: AE Area: 1.6 acres Number of Lots: 1 Property Owner: Matt and Zanna Frost Applicant: Matt and Zanna Frost Request: Applicant is seeking conditional use approval to add an ADU on their 1.6 acre property. ______________________________________________________________________________ Background Information The applicant is requesting a conditional use permit to add an accessory dwelling unit (ADU) to their property at 753 West Glovers Lane. The ADU, while substantial, is still subordinate in height and area to the main dwelling. The ADU will have frontage of Davis County Road (750 West), also referred to as the Sheep Road. Per 11-32-060, one driveway is allowed per street frontage. The ADU would house family members of the applicant. On May 6, 2021 the Planning Commission held a public hearing for this item, and at that time, decided to table it due to water quality and soil stability concerns surrounding an artesian well on the property, because of the close proximity of a proposed sewer lateral for the ADU. Suggested Motion Move the Planning Commission approve the Frost ADU conditional use, subject to all applicable Farmington City ordinances and development standards. And on the condition that the sewer district approve any proposed laterals, or other improvements, prior to issuance of any building permit. Findings for Approval: 1. The ADU increases housing density without the need for a lot split or subdivision. 1
2. The parcel can be subdivided in the future , subject to the City’s subdivision process, if future home owners find it necessary, otherwise the ADU can be rented in the future to others. 3. The applicant provided a technical memorandum from AQUA Engineering, which resolves the proximity concern of the proposed sewer lateral to the well, acceptable to members of the City’s DRC (Development Review Committee). Supplemental Information 1. Vicinity Map 2. Proposed site plan and elevations 3. AQUA Engineering Technical Memorandum, April 13, 2021 4. Shannon Hansell/Manjot Masson emails: May 18, 2021 2
Country Lane 08-562-0105 08-356-0323 08-356-0314 08-562-0104 08-356-0315 08-077-0025 08-356-0322 08-562-0103 08-562-0120 08-356-0342 08-356-0321 08-356-0316 08-465-0006 08-535-0005 08-562-0102 08-535-0004 08-356-0320 08-356-0317 08-535-0006 08-535-0003 08-562-0101 08-356-0318 08-535-0008 08-356-0319 08-535-0007 08-077-0001 Glovers Lane (925 South) Glovers Lane (925 South) 08-079-0032 08-079-0020 08-079-0019 08-079-0029 08-079-0044 08-079-0030 08-079-0045 Sheep Road 08-079-0031 (725 W est) 08-079-0046 08-079-0041 08-079-0010 08-079-0011 08-079-0038 08-079-0012 08-079-0036 08-079-0033 08-079-0035 08-079-0018 0 50 100 150 200 VICINITY MAP Feet 753 West Glovers Lane Meters Date: 4/29/2021 0 10 20 30 40
COPYRIGHT © SHEET INDEX Dream Home Design 2021 COVER PAGE COVER PAGE Dream Home Design PAGE # 1 SITE PLAN ideas and drawings are property PAGE # 2 FOUNDATION PLAN of Dream Home Design and may not be reproduced PAGE # 3-M MAIN FLOOR PLAN without written permission under penalty of law. PAGE # 4 ELEVATIONS PAGE # 5 ROOF OVERVIEW PAGE # 6-M MAIN ELECTRICAL LIABILITY GENERAL NOTES Dream Home Design PAGE # 7 SECTION AND DETAILS is not accountable and will not be legally responsible for Structural Engineering concerning this plan. If Structural Engineering is required, it will become the responsibility of the Client and/or Contractor. ORIGINAL DRAWN BY: K. CHRISTENSEN ORIGINAL DRAWN DATE: 11-30-2020 REVISED BY: K. CHRISTENSEN REVISION DATE: 3.26.2021 esign info@dreamhomedesign.biz I 435-627-3146 I www.dreamhomedesign.biz FRONT ELEVATION SCALE: 1/4" = 1'-0" Dream Home COVERED PATIO M. BATH MASTER BEDROOM KITCHEN M. CLOSET LNDRY FAMILY ROOM 2-CAR GARAGE BATH HALL PARCEL, LOT # 08-079-0021 FARMINGTON, UTAH ENTRY DINING BEDROOM MATT FROST BEDROOM COVERED PORCH SQUARE FOOTAGE MAIN LEVEL LIVING AREA 1651 SQ. FT. FRONT COVERED PORCH 84 SQ. FT. REAR COVERED PATIO 257 SQ. FT. MAIN FLOOR PLAN SCALE: 1/4" = 1'-0" GARAGE 675 SQ. FT. TOTAL UNDER ROOF 2,666 SQ. FT. COVER PAGE
COPYRIGHT © Dream Home Design 2021 Dream Home Design ideas and drawings are property of Dream Home Design and may not be reproduced without written permission under penalty of law. NORTH LIABILITY S 89° 52' 30" E Dream Home Design is not accountable and will not be legally 255.70' N 00° 00' 08" E responsible for Structural Engineering concerning this plan. If Structural Engineering is required, it 21.96' will become the responsibility of the Client and/or Contractor. 83.21' S 00° 12' 15" W ORIGINAL DRAWN BY: K. CHRISTENSEN ORIGINAL DRAWN DATE: 11-30-2020 REVISED BY: K. CHRISTENSEN REVISION DATE: 3.26.2021 esign info@dreamhomedesign.biz I 435-627-3146 I www.dreamhomedesign.biz 177.00' S 89° 30' 47" E GLOVERS LANE EXISTING HOUSE Dream Home 218.91' N 89° 47' 45" W DRIVEWAY 75'-6" OVERALL WIDTH 200 METER AMP 41'-6" OVERALL DEPTH PHONE CABLE GAS ELEC & GAS METER NOTE: MAIN ELECTRICAL SERVICE PANEL & METER PROPOSED BLDG - PROVIDE UFER GROUND PER LOCAL CODE REQUIREMENTS. EXACT SIZE & LOCATION TO BE DETERMINED ON-SITE GAS METER TO BE 48" AWAY FROM ELECTRICAL SERVICE (MIN.) EXACT SIZE & LOCATION TO BE DETERMINED ON-SITE 18'-0" ENTRY SETBACK NOTE: SETBACKS ON LOT ARE AS FOLLOWS: DRIVEWAY 25 FOOT FRONT YARD SETBACK 30'-0" 8 FOOT AND 10 FOOT SIDE YARD SETBACK 10 FOOT REAR SETBACK E DRAINAGE ' 0 0 " 10° 45 PARCEL, LOT # 08-079-0021 3.7 9 ' S PUBLIC UTILITY AND 34 DRAINAGE EASEMENT: FARMINGTON, UTAH ) THERE EXISTS A 10 FOOT PUBLIC E E T UTILITY AND DRAINAGE EASEMENT T STR ALONG STREET SIDE PROPERTY LINE S AND A 7.5 FOOT EASEMENT ALONG E MATT FROST W SIDE AND BACK LOT LINES. 20'-81 8" 18'-0" OAD (750 N TY R LEGAL DESCRIPTION DRAINAGE NOTE: C OU DRAINAGE SHALL BE AWAY FROM HOUSE VIS AND SLOPE TOWARDS PUBLIC STREET. DA PARCEL # 08-079-0021 68,942 SQ. FT. IF REQUIRED, RELATIVE ELEVATIONS OF TOP OF FINISHED FLOOR, LOT CORNERS AND STREET GRADES/FINISHED GRADES SHALL BE PROVIDED BY CIVIL ENGINEER. 753 W. GLOVER LANE FARMINGTON, UTAH NOTE: DREAM HOME DESIGN SHALL NOT BE RESPONSIBLE FOR ACCURACY OF INFORMATION FOR ANY REQ'D LOT SITE PLAN SCALE: 1/16" = 1'-0" CORNER ELEVATIONS, SEWER PHONE, GAS, ELECTRICAL, CABLE, & ALL OTHER UTILITY INFORMATION PROVIDED BY CONTRACTOR/OWNER PAGE # 1 SITE PLAN
COPYRIGHT © NOTE Dream Home Design 2021 SEE STRUCTURAL ENGINEERING Dream Home Design ideas and drawings are property FOR ADDITIONAL NOTES, of Dream Home Design FOOTINGS, DETAILS, ETC. and may not be reproduced without written permission under penalty of law. SPECIAL FOUNDATION NOTE ANCHOR BOLTS SHALL BE LOCATED WITHIN 12 INCHES LIABILITY Dream Home Design FROM THE ENDS OF EACH PLATE SECTION AT INTERIOR is not accountable and BEARING WALLS, INTERIOR BRACED WALL LINES & AT will not be legally ALL EXTERIOR WALLS. PLATE WASHERS A MIN. OF responsible for Structural 2 INCHES BY 2 INCHES BY 3/16 INCH THICK SHALL Engineering concerning this plan. If Structural BE USED ON EACH BOLT. Engineering is required, it WHEN ANCHOR BOLT SPACING DOES NOT EXCEED 32 will become the INCHES APART, A PROPERLY SIZED ROUND WASHER responsibility of the Client FOOTINGS UNDER NON BEARING BRACE WALLS MAY BE and/or Contractor. SCOOP FOOTINGS MIN. 10 INCHES DEEP/10 INCHES WIDE. ORIGINAL DRAWN BY: K. CHRISTENSEN 75'-6" ORIGINAL DRAWN DATE: 25'-0" 27'-0" 23'-6" 11-30-2020 18'-0" 7'-0" 1'-6" 12'-0" 1'-6" 12'-0" REVISED BY: K. CHRISTENSEN REVISION DATE: 6'-0" 3'-0" 2'-1" 3.26.2021 1'-6" esign info@dreamhomedesign.biz I 435-627-3146 I www.dreamhomedesign.biz 4'-0" CURBLESS SLOPE SLOPE SHOWER 9'-6" 9'-6" 10'-4" 8'-0" CONCRETE PATIO 6'-4" 3'-0" WS WH F.A.U. R.AIR 4'-0" Dream Home DW DB'L SINK 1'-8" 6'-10" 2'-0" 8" GARAGE STEM WALL 6'-8" 6'-8" 8'-6" 8'-2" 3'-4" PROVIDE UNDERGROUND CONDUIT FOR KITCHEN ISLAND ELECTRICAL BREAK STEM WALL TO FLOOR FOR DOOR. PROVIDE CONTINUOUS DRYER FOOTING ACROSS 3'-9" 2'-10" 1'-8" 3'-9" OPENING. SLOPE 1/8" PER FOOT 38'-0" 5'-6" WASHER TO DRAIN 41'-6" 41'-6" 2'-101 2" 27'-0" 27'-0" 4" CONC. SLAB O/ APP. SOIL 8" GARAGE STEM WALL 6'-10" 3'-0" 19'-8" 19'-2" BREAK STEM WALL TO FLOOR FOR DOOR. PROVIDE CONTINUOUS FOOTING ACROSS OPENING. 14'-4" 12'-8" 13'-0" 10'-6" 3'-0" 1'-6" 4'-8" 4'-8" 5'-0" CONCRETE PORCH 1'-8" 1'-8" 2'-0" SLOPE 3'-6" 1'-10" 1'-10" 1'-10" PARCEL, LOT # 08-079-0021 1'-6" FARMINGTON, UTAH 2'-0" 9'-4" 2'-0" MATT FROST 2'-4" 18'-4" 4'-4" 14'-0" 13'-4" 12'-8" 10'-6" 75'-6" 2x STUD FRAMED WALL STUCCO FINISH PER CODE "J" METAL WITH WEEP CONCRETE & ABOVE ROOF AT DORMERS 6" MIN. ABV. SOIL CONCRETE 2" MIN. UNDER PATIO (SLOPE AWAY FROM HOUSE) min. 6" 2" FINISH GRADE (SLOPE AWAY FROM HOUSE) FOUNDATION PLAN SCALE: 1/4" = 1'-0" WEEP SCREED/ J. METAL 1/2" = 1'-0" PAGE # 2 FOUNDATION
COPYRIGHT © Dream Home Design 2021 Dream Home Design ideas and drawings are property of Dream Home Design and may not be reproduced NOTE: without written permission under penalty of law. UP FLOW F.A.U.- PROVIDE COMBUSTION AIR & CONDENSATE LINE TO OUTSIDE OR APPROVED DRAIN. LIABILITY PROVIDE SETBACK THERM. & SUMMER FAN SWITCH. Dream Home Design is not accountable and NOTES: will not be legally responsible for Structural Engineering concerning this plan. If Structural · 2X4 EXTERIOR WALLS. Engineering is required, it will become the · 9'-0" PLATE HEIGHT UNLESS responsibility of the Client OTHERWISE NOTED and/or Contractor. · 8'-0" WINDOW HEADER HEIGHT Section Page ORIGINAL DRAWN BY: 7 A UNLESS OTHERWISE NOTED. K. CHRISTENSEN 75'-6" · PROVIDE BACKFLOW PREVENTION ORIGINAL DRAWN DATE: 25'-0" 27'-0" 23'-6" FOR ALL HOSE BIBBS. 11-30-2020 18'-0" 7'-0" 1'-6" 12'-0" 1'-6" 12'-0" 12'-8" 6'-6" 4'-4" REVISED BY: 6'-6" 6'-2" 3'-6" 3'-0" 2'-3" 2'-1" K. CHRISTENSEN REVISION DATE: 3.26.2021 2'-0" x 2'-0" FIXED A/C CONDENSER 1'-6" 6'-0" x 5'-0" SLIDER 2X6 WALL 2'-4" esign 4'-0" x 2'-0" SLIDER 3'-0" x 8'-0" 2X6 WALL 4'-4" info@dreamhomedesign.biz I 435-627-3146 I www.dreamhomedesign.biz 6'-4" CURBLESS 6'-0" x 4'-0" SHOWER COVERED PATIO 9'-6" 10'-4" 3'-0" x 6'-8" 8'-0" 3'-0" x 5'-0" 18" HIGH PLATFORM SG HUNG 9' CEILING 7'-2" M. BATH POCKET PROVIDE SEISMIC STRAPS AND THERMAL EXPANSION 9' CEILING TANK FOR WATER HEATER PROVIDE COMBUSTION AIR 6'-4" 14'-8" 6'-0" MASTER BEDROOM 3'-6" 3'-6" 3'-10" 4'-0" BBQ 9' CEILING HOSE BIBB 3'-6" x 4'-0" SLIDER 12'-4" x 15'-6" 6'-0" x 8'-0" FRENCH DB'L WH F.A.U. 2X6 WALL 2X6 WALL 3'-4" WS R.AIR Dream Home DW 5'-8" DB'L SINK 6'-4" 6'-8" 6'-0" x 6'-8" DB'L LIFT AREA KITCHEN 8'-2" 4'-6" 10'-10" 8'-0" 3'-0" x 8'-0" 9' CEILING M. CLOSET DB'L ROD 10'-2" x 7'-8" HOOD ABOVE SHLVS RANGE W/ 3'-0" x 6'-8" PROVIDE COMBUSTION AIR 3'-0" x 5'-6" ISLAND DRYER SG'L ROD DB'L ROD 2X6 PLUMBING WALL LNDRY 38'-0" 2X6 PLUMBING WALL 5'-6" 2-CAR GARAGE PANTRY SHELVES WASHER 9' CEILING 8'-4" 3'-6" FAMILY ROOM 4'-0" x 2'-0" SLIDER 9' CEILING 41'-6" 41'-6" TUB/SHWR 6'-0" 6'-10" 3'-0" 9' CEILING 4'-6" VANITY 1 LAYERS 5/8" TYPE "X" " -8 GYPBOARD ON ALL WALLS ATTIC 27'-0" BATH 6' FRIDGE 2'-6" "X AND CEILINGS COMMON ACCESS -8 9' CEILING 2' WITH DWELLING. ANY PENETRATIONS MUST 2X6 WALL BE SEALED WITH FIRE-RATED 3'-0" x 6'-8" 2'-4" DB'L ROD SG'L ROD 21'-4" CAULK, ADHESIVE, OR 3'-0" x 8'-0" POCKET 3'-0" x 6'-8" HALL 4'-6" EXPANDING FOAM FIRE W/ CLOSER 5'-0" x 6'-8" DB'L (20 MINUTE) 9' CEILING 5'-8" 4'-0" 6'-10" 3'-0" x 6'-8" SHELVES 5'-0" x 5'-0" SLIDER 4'-0" x 8'-0" DB'L 4'-6" ENTRY 9'-10" DINING 6'-4" 9' CEILING BEDROOM 11'-4" 3'-0" x 8'-0" SG'L ROD 9' CEILING 9' CEILING 13'-8" x 9'-0" 10'-2" x 10'-8" BEDROOM DB'L ROD 5'-8" 9' CEILING 5'-0" x 6'-8" DB'L (2) 1'-6" x 6'-0" FIX. TEMP. HOSE 18'-0" x 8'-0" GARAGE DOOR 10'-0" x 10'-8" BIBB 6'-10" 3'-0" 3'-7" 2'-9" 2'-9" 1'-3" 2'-4" 1'-6" 4'-8" 4'-8" (3) 2'-6" x 5'-0" FIXED 5'-0" x 2'-0" FIXED COVERED SG'L ROD 4" PORCH 1'-8" 1'-8" 2'-0" 10' CEILING 5'-0" x 5'-0" SLIDER 3'-6" 1'-10" 1'-10" 1'-10" PARCEL, LOT # 08-079-0021 1'-6" FARMINGTON, UTAH 4'-2" 3'-0" 3'-0" 3'-10" 6'-2" 3'-10" 5'-1" 5'-5" 2'-0" 9'-4" 2'-0" 10'-0" 2'-8" MATT FROST 2'-6" 18'-0" 4'-6" 14'-0" 13'-4" 12'-8" 10'-6" 75'-6" A Section 7 Page SQUARE FOOTAGE MAIN LEVEL LIVING AREA 1651 SQ. FT. FRONT COVERED PORCH 84 SQ. FT. REAR COVERED PATIO 257 SQ. FT. MAIN LEVEL FLOOR PLAN SCALE: 1/4" = 1'-0" GARAGE 675 SQ. FT. TOTAL UNDER ROOF 2,666 SQ. FT. PAGE # 3-M MAIN FLOOR PLAN
COPYRIGHT © Dream Home Design 2021 Dream Home Design 12 ideas and drawings are property LOUVERED ATTIC VENT. PROVIDE ATTIC VENTILATION of Dream Home Design 8 and may not be reproduced ROOF SHINGLES ACCORDING TO CODE. SEE PAGE 5-1 AND PAGE 7 without written permission under penalty of law. LIABILITY Dream Home Design is not accountable and 22'-7" TOTAL BUILDING HEIGHT will not be legally responsible for Structural Engineering concerning this plan. If Structural 6" STUCCO Engineering is required, it FASCIA will become the responsibility of the Client and/or Contractor. ORIGINAL DRAWN BY: 9'-0" PLATE HEIGHT 11-30-2020 8'-0" TYP. HEADER HEIGHT ORIGINAL DRAWN DATE: 6-15-2020 REVISED BY: K. CHRISTENSEN REVISION DATE: 3.26.2021 FINISH FLOOR APPROX. FINISH GRADE esign CONCRETE PORCH STUCCO FINISH PER CODE W/ BRICK ROCK GARAGE DOOR SLOPE AWAY FROM STUCCO SCREED 2" ABOVE info@dreamhomedesign.biz I 435-627-3146 I www.dreamhomedesign.biz HOUSE FINISH CONCRETE AND 6" ABOVE FINISH GRADE. FRONT ELEVATION 12 8 Dream Home 12 8 10'-0" ENTRY PLATE HEIGHT 9'-0" PLATE HEIGHT 10'-0" ENTRY PLATE HEIGHT FINISH FLOOR 9'-0" PLATE HEIGHT APPROX. FINISH GRADE 8'-0" TYP. HEADER HEIGHT GARAGE CONCRETE PATIO. STUCCO COLUMN MAN SLOPE AWAY FROM DOOR HOUSE LEFT ELEVATION FINISH FLOOR APPROX. FINISH GRADE BRICK COLUMN ROCK RIGHT ELEVATION 12 8 PARCEL, LOT # 08-079-0021 FARMINGTON, UTAH MATT FROST 9'-0" PLATE HEIGHT FINISH FLOOR APPROX. FINISH GRADE CONCRETE PATIO. PATIO FRENCH DOOR STUCCO COLUMN SLOPE AWAY FROM STUCCO COLUMN HOUSE REAR ELEVATION ELEVATIONS SCALE: 1/4" = 1'-0" PAGE # 4-1 ELEVATIONS
COPYRIGHT © ROOF OVERVIEW NOTES: Dream Home Design 2021 1. TRUSS LAYOUT, LOAD DESIGN, AND Dream Home Design ENGINEERING PROVIDED BY OTHER. ideas and drawings are property of Dream Home Design and may not be reproduced 2. CONTRACTOR/BUILDER SHALL without written permission under penalty of law. COORDINATE BUILDING ROOF WITH THESE PLANS, STRUCTURAL ENGINEERED PLANS, AND TRUSS LIABILITY PLANS PROVIDED BY TRUSS Dream Home Design MANUFACTURER. is not accountable and will not be legally 3. REFER TO NOTES ON ROOF responsible for Structural OVERVIEW AND ELEVATIONS FOR Engineering concerning VARIOUS ROOF PITCHES. this plan. If Structural Engineering is required, it will become the 4. REFER TO ROOF OVERVIEW FOR responsibility of the Client ROOF OVERHANG SIZES. and/or Contractor. ORIGINAL DRAWN BY: ATTIC VENTILATION: K. CHRISTENSEN ATTIC VENTILATION SHALL BE PROVIDED EITHER: ORIGINAL DRAWN DATE: 2886 SQ. FT. : 150 = 20 SQ. FT. VENTS 11-30-2020 OR 2886 SQ. FT. : 300 = 10 SQ. FT. VENTS REVISED BY: 9'-0" PLATE HEIGHT UNLESS OTHERWISE NOTED DEPENDING ON VENT SYSTEM AS DESCRIBED K. CHRISTENSEN ON SHEET # 1 "ATTIC VENTILATION." MANUFACTURED TRUSSES @ 24" O.C. UNLESS OTHERWISE NOTED REVISION DATE: 3.26.2021 esign info@dreamhomedesign.biz I 435-627-3146 I www.dreamhomedesign.biz Dream Home HI P HI P 8/12 PITCH VA LL EY HI P 8/12 PITCH RIDGE 8/12 PITCH 8/12 PITCH RIDGE ATTIC 8/12 PITCH ACCESS 8/12 PITCH P HI P HI YE HI P LL EY VA VA LL LL VA EY RIDGE 1'-4" 8/12 PITCH 8/12 PITCH TYP. OVERHANG 10" PARCEL, LOT # 08-079-0021 RIDGE 6" 10" 10" 2'-4" 6" 6" FARMINGTON, UTAH 10'-0" PLATE HEIGHT 2'-4" 2'-4" MATT FROST ROOF OVERVIEW SCALE: 1/4" = 1'-0" PAGE # 5-1 ROOF OVERVIEW
COPYRIGHT © Dream Home Design 2021 Dream Home Design ideas and drawings are property of Dream Home Design and may not be reproduced without written permission under penalty of law. LIABILITY Dream Home Design is not accountable and will not be legally responsible for Structural Engineering concerning this plan. If Structural Engineering is required, it will become the responsibility of the Client and/or Contractor. ORIGINAL DRAWN BY: K. CHRISTENSEN ORIGINAL DRAWN DATE: 11-30-2020 REVISED BY: K. CHRISTENSEN REVISION DATE: 3.26.2021 A/C CONDENSER esign info@dreamhomedesign.biz I 435-627-3146 I www.dreamhomedesign.biz WP SS SSS MAIN ELECTRICAL SERVICE PANEL & METER. PROVIDE GAS METER TO BE 48" AWAY UFER GROUND PER LOCAL FROM ELEC. SERVICE (MIN.) PHONE CABLE CODE REQUIREMENTS. SIZE & LOCATION TO BE WP/GFI DETERMINED ON-SITE GFI SS VERIFY LOCATION. BBQ GAS 2-L S S SSS GFI 220 220 GFI GFI GFI GFI GFI GAS GAS S Dream Home GFI S PROVIDE DW OUTLET GFI AF GFI SSS 220 DRYER GFI SS WASHER WP/GFI S 2-L GFI GFI GFI GFI GFI SS +42" GFI ATTIC GFI GFI WP ACCESS S FOR OPENER IN CLG. AF GFI S AF SSS SSS SS SS GFI TO GARAGE OPENER GFI AF ELECTRICAL LEGEND S S SS S S S S LIGHT SWITCH IN SOFFIT SD DIMMER SWITCH WP/GFI DUPLEX RECEPTACLE OUTLET IN SOFFIT AF WP/GFI WP/GFI ARC FAULT INTERRUPTER DUPLEX RECEPTACLE OUTLET GFI GROUND FAULT INTERRUPTER DUPLEX RECEPTACLE OUTLET WP/GFI WATER PROOF G.F.I. DUPLEX RECEPTACLE OUTLET 220 V. OUTLET PARCEL, LOT # 08-079-0021 GAS STUB SURFACE MOUNT LIGHT FIXTURE OPT. CAN LIGHTS IN SOFFIT FARMINGTON, UTAH WALL MOUNT LIGHT FIXTURE RECESSED CAN LIGHT MATT FROST MINI-CAN LIGHT/PUCK LIGHT FLOOD LIGHT FLUORESCENT LIGHT FIXTURE TRACK LIGHTING CEILING FAN W/ LIGHT. SIZE & STYLE PER OWNER IN WALL, OR TRED STAIRWAY LIGHTS UNDER KITCHEN CABINET LIGHTS PENDANT LIGHT EXHAUST FAN AF SMOKE DETECTOR W/BATTERY BACK-UP. AF CARBON MONOXIDE DETECTOR W/BATTERY BACK-UP. TELEVISION JACK MAIN FLOOR ELECTRICAL PLAN SCALE: 1/4" = 1'-0" 2-L TELEPHONE JACK TELEPHONE & SEPERATE COMPUTER LINE IN ONE JUNCTION BOX. DOOR BELL TO CHIMES INSIDE. PAGE # 6-M MAIN ELECTRICAL
COPYRIGHT © Dream Home Design 2021 GENERAL NOTES (REFER TO 2018 I.R.C.) Dream Home Design ideas and drawings are property of Dream Home Design and may not be reproduced PLUMBING WALL SECTIONS without written permission under penalty of law. 1. PROVIDE SEISMIC STRAPS AND THERMAL 8. PLUMBING VENTS SHALL BE AT LEAST EXPANSION PROTECTION ON W/H. 3 FEET ABOVE OR 10 FEET AWAY FROM 1. SOLID BLOCKING REQ'D AT BEARING 2. LOW-FLUSH TOILETS REQ'D, MAX. 1.6 ALL OUTSIDE AIR INTAKE OPENINGS. POINTS FOR FLOOR JOISTS. LIABILITY GALLONS/FLUSH. 9. ALL HOSE BIBBS TO BE FREEZELESS 2. SOLID BLOCKING REQ'D AT BEARING AND HAVE BACK FLOW PREVENTOR. POINTS FOR ROOF RAFTERS, TRUSSES, Dream Home Design 3. MAX. FLOW RATE OF SHOWER HEADS IS 2.5 GALLONS/MINUTE. 10. WATER SERVICE SIZE SHALL BE 3/4". & CIELING JOISTS. is not accountable and 4. OUTSIDE COMBUSTION AIR REQ'D FOR 11. ALL WATER HEATER ROOMS SHALL 3. FIRE BLOCK CONSTRUCTION PER IRC R602.8 will not be legally WATER HEATER. HAVE FLOOR DRAIN. 4. OFFSETS AT BEARING PARTITIONS MAY responsible for Structural 5. SHOWER SIZE MINIMUM 1024 SQ. INCHES 12. WATER HEATER TO HAVE A DOUBLE NOT EXCEED JOIST DEPTH. Engineering concerning W/ 30" DIA. CIRCLE WITHIN AREA, FINISHED WALL TYPE "B" CONNECTOR FROM W/H 5. WEATHER BARRIER REQ'D UNDER SIDING, this plan. If Structural TO A HEIGHT OF 70" ABOVE DRAIN INLET. TO MAIN FLUE IN ATTIC OR THROUGH BRICK, STUCCO, ETC. Engineering is required, it 6. WATER HEATER TO BE INSTALLED IN METAL ATTIC TO 1'-0" MINIMUM ABOVE ROOF 12 AND SHALL HAVE A CEILING THIMBLE will become the PAN W/ DRAIN WHEN LEAKAGE MAY CAUSE 6. ANY PENETRATIONS THROUGH A FIREWALL OR 8 DAMAGE. IRC P2801.5.1 & P2801.5.2. TO TERMINATE ABOVE INSULATION. CEILING SHALL BE CAULKED AND TAPED BY AN responsibility of the Client 7. A WATER-HAMMER ARRESTOR SHALL BE 13. PROVIDE W/H EXPANSION TANK APPROVED FIRE PRODUCT. and/or Contractor. INSTALLED WHERE QUICK-CLOSING VALVES ARE UTILIZED, UNLESS OTHERWISE APPROVED. WATER-HAMMER ARRESTORS SHALL NOTE: ORIGINAL DRAWN BY: CONFORM TO ASSE/ANSI 1010. MANUFACTURED TRUSSES K. CHRISTENSEN SHEATH ENTIRE EXTERIOR OF @ 24" O.C. STRUCTURE W/ 7 1/16 WAFERWELD. MECHANICAL ORIGINAL DRAWN DATE: 1. COMBUSTION AIR TO BE TAKEN FROM 6. VENT CLOTHES DRYER TO OUTSIDE. DUCTS ELEVATIONS 11-30-2020 OUTSIDE. TO BE METAL WITH SMOOTH INTERIOR R-38 INSULATION REVISED BY: SURFACES, EQUIPPED W/ BACK-DRAFT DAMPERS 1. FLASH AND COUNTER FLASH ALL 2. COMBUSTION AIR DUCTS TO BE LOCATED EXTERIOR OPENINGS. K. CHRISTENSEN TERMINATE AT THE EXTERIOR OF THE BUILDING WITHIN THE UPPER 12" OF CEILING AND AND NOT TO BE INSTALLED W/ SHEET METAL WITHIN 12" OF THE FLOOR. 2. ATTIC VENTILATION: 1 SQ. FT. / 150 SQ. SCREWS. MAX. LENGTH DRYER DUCT 14' W/ FT. OF ATTIC AREA, UNLESS PROVISIONS UPPER REVISION DATE: 3. DUCTS USED FOR COMBUSTION TO TWO 90 DEGREE ELBOWS, MIN. DUCT DIA. 4" 3.26.2021 REMAIN SEPARATE FROM THE ENCLOSURE ARE MET FOR 1/300 RATIO. SEE ATTIC VENTILATION COV'D HEADER PER ENG. CABINET UPPER HOOD UPPER HEADER PER ENG. BEAM(S) PER ENG. TO THE OUTSIDE AIR SOURCE. 7. MIN. 30" CLEARANCE REQ'D ABOVE RANGE TOP FOUNDATION PLAN PORCH 10'-0" CEILING CABINET CABINET STUCCO 4. FURNACES IN A CLOSET SHALL HAVE A MIN. TO COMBUSTIBLES. 9'-0" CEILING 9'-0" CEILING TO COV'D WRAP esign 3" CLEAR WORKING SPACE ON SIDES, BACK, GARAGE 8. COOKTOPS & MICROWAVES INSTALLED ABOVE BEAM ENTRY DOOR 1. ALL STEEL GRADE 60 MINIMUM. FRIDGE PATIO DOOR AND TOP. info@dreamhomedesign.biz I 435-627-3146 I www.dreamhomedesign.biz COOKTOPS SHALL CONFORM TO THE CONDITIONS 5. LOCATION OF VENT TERMINAL. AN OPEN OF THEIR LISTINGS. 2. PROVIDE UFER GROUND IN FTG @ ENTRY PATIO VENT TERMINAL FROM A DRAINAGE SYSTEM SERVICE ENTRANCE LOCATION. STOVE SHALL NOT BE LOCATED LESS THAN 4 9. BATHROOMS & LAUNDRY ROOMS WITHOUT AN OPENABLE WINDOW ARE REQ'D TO HAVE EXHAUST FLOOR PLAN CABINET FEET (1219 mm) DIRECTLY BENEATH ANY LOWER DOOR, OPENABLE WINDOW, OR OTHER FANS PROVIDING 5 AIR CHANGES PER HOUR. ISLAND LOWER AIR INTAKE OPENING OF THE BUILDING 10. PROVIDE COMBUSTION AIR TO LAUNDRY AREA. CABINET OR OF AN ADJACENT BUILDING, NOR 1. ALL HEADERS TO BE DOUBLE 2x10 UNLESS NOTED. FINISH FLOOR FINISH FLOOR SHALL ANY SUCH VENT TERMINAL BE 11. VENTS SHALL NOT BE USED AS FLAG POLES, WITHIN 10 FEET (3048 mm) HORIZONTALLY T.V. ARIALS ETC. UNLESS CONSTRUCTED 2. SMOKE DETECTORS TO BE 12" MIN. FROM PEAKS OF CEILING. APPROX. FINISH GRADE APPROX. FINISH GRADE OF SUCH AN OPENING UNLESS IT IS AT FOR SUCH. IRC P3103.4 LEAST 2 FEET (610 mm) ABOVE THE TOP 3. ALL DECK OR BALCONY FLOORS TO BRICK COLUMN STUCCO COLUMN 12. FURNACE WORKING SPACE MUST COMPLY 4" REINFORCED CONCRETE SLAB OF SUCH AN OPENING. IRC P3103.5 W/ IMC & FUEL GAS CODE. SLOPE A MINIMUM OF 1" FOR DRAINAGE. 4" CONCRETE PORCH. SLOPE AWAY FROM HOUSE. COMPACTED SOIL 4" CONCRETE PATIO. SLOPE AWAY FROM HOUSE. 4. PROVIDE WATER RESISTANT (GREENBOARD) FOOTING - SEE GENERAL WALL DETAIL ELECTRICAL SHEETROCK IN ALL SHOWERS. 5. PROVIDE MIN. 22" X 30" ATTIC ACCESS. SECTION A Dream Home 1. SMOKE DETECTORS SHALL BE HARD WIRED 6. ANY LIGHT FIXTURES OVER TUBS & SCALE: 1/4" = 1'-0" TOGETHER IN SERIES W/ BATTERY BACK SHOWERS SHALL BE GFI. ROOF NOTES UP. IRC R313.2 7. PROVIDE 30" WIDE X 36" DEEP FOR AC APPLY 30'-0" FELT O/ SHEATHING FOR 2. BATHROOM RECEPTACLE OUTLETS SHALL DISCONNECT BE SUPPLIED BY DEDICATED 20 AMP COMPO & METAL & 30' FELT O/ SHTG. W/ 8. PROVIDE ROOF CAP WITH BACKDRAFT 1 X 2 BATTENS FOR TILE & SHAKE ROOFS. BRANCH CIRCUIT W/ NO OTHER OUTLETS. DAMPER AND BIRDSCREEN. 3. ALL BEDROOM OUTLETS TO BE ARC-FAULT TYPE MAX. 9. PROVIDE ATTIC LIGHT, CATWALK, COMBUSTION AIR AND VENT FURNACE INSULATION 8 OUTLETS PER BREAKER INCLUDING SWITCHES & AS REQUIRED BY UMC. SMOKE DETECTORS 1. INSULATION CONTRACTOR TO PROVIDE 10. PROVIDE GFCI PROTECTED SERVICE COMPLETE MECCHECK PRIOR TO 4. ALL CEILING FANS TO HAVE FAN OUTLET (125 VOLT) WITHIN 25 FT. OF SHINGLES ROOF INSTALLATION OF INSULATION. RATED BOX W/ ADD'L SUPPORT HEATING AND AIR CONDITIONING PER OVER APPROVED AS REQUIRED. NEC. 210.63 '02. 2. INSULATE WATER LINES AND DUCTS IN ALL TAR PAPER 5. ALL KITCHEN SURFACE OUTLETS, BATH WALLS AND CEILINGS. 7/16" EXTERIOR SHEATHING OVER OUTLETS, & GARAGE OUTLETS TO BE GFI 3. CEILING INSULATION TO BE R-38 BLOWN SHOP ENGINEERED & MANUFACTURED END AT ENTIRE HEATED CEILING AREA AND TRUSSES @ 24" O.C. (USE ENGINEERS SPECIFIED NAILING PATTERNS.) CONC. FDN WALL DESIGN R-38 UNFACED BATTS AT UNBLOWABLE CEILING AREA. 2X BLOCKING 4. EXTERIOR WALLS TO BE R-13 UNFACED SIMPSON A35 CLIP @ EACH WALL OPENINGS: TRUSS END. (TYP.) BATTS INCLUDING AT RIM JOISTS. MAXIMUM LINTEL LENGTH = 6' 5. ALL INSULATION SHALL BE UL AND/OR ICBO MINIMUM LINTEL DEPTH = 2"/FOOT OF OPENING (MINIMUM 6") APPROVED. R-30 INSULATION MIN. REINFORCEMENT AROUND OPENING (PLACE WITHIN 2" OF OPENING AND 3" OF TOP OF 2X FASCIA 6. PROVIDE INSULATION DAMS AS REQIRED DOUBLE TOP PLATE WALL, AND EXTEND STEEL 24" BEYOND OPENING ON SIDES AND BOTTOM): SOFFIT VENTS AS AT EAVE VENT. REQUIRED (TYP.) 2-#4 ABOVE OPENING 2X4 SOFFIT 1/2" GYP. BOARD 1-#4 EACH SIDE OF OPENING 1-#4 BELOW OPENING STAIRWAY NOTES FURRING STAIRWAY SHALL NOT BE LESS THAN 36" IN CLEAR WIDTH STUCCO EXTERIOR FINISH REFER TO FLOOR PLAN FOR PLATE HEIGHT WALL REINFORCING: OVER CODE APPROVED WALL HEIGHT AT ALL POINTS ABOVE THE PERMITTED HANDRAIL HEIGHT FELT PAPER MINIMUM WALL THICKNESS = 8" AND BELOW THE REQ'D HEADROOM HEIGHT. HANDRAILS 8' 9' 10' SHALL NOT PROJECT MORE THAN 4.5" ON EITHER SIDE OF 1 1/2" FOAM BOARD STAIRWAY AND THE MINIMUM CLEAR WIDTH OF THE VERTICAL REINFORCEMENT #4 @ 24" O.C. #4 @ 16" O.C. #4 @ 12" O.C. STAIRWAY AT AND BELOW THE HANDRAIL HEIGHT, INCLUDING TREADS AND LANDINGS SHALL NOT BE LESS APPROVED EXTERIOR PLACE IN THE CENTER OF THE WALL, AND EXTEND FROM FOOTING THAN 31.5" WHERE A HANDRAIL IS INSTALLED ON ONE SIDE SHEATHING AND/OR SHEAR TO WITHIN 3" OF TOP OF WALL. INSERT #4 DOWELS IN FOOTING AND 27" WHERE HANDRAILS ARE PROVIDED ON BOTH WALL AS PER ENGINEERING. TO MATCH VERTICAL SPACING - EXTEND 24" INTO FOUNDATION SIDES. MIN. HORIZONTAL REINFORCEMENT 6- #4 @ 17.5" 7- #4 @ 16.5" 9- #4 @ 14" HEADROOM SHALL NOT BE LESS THAN 6'-8" MEASURED VERTICALLY FROM THE SLOPED LINE ADJOINING THE TREAD PLACE ONE BAR 4" FROM TOP OF WALL, ONE BAR 4" FROM BOTTOM NOSING OR FROM THE FLOOR SURFACE OF THE LANDING OF WALL, EQUALLY SPACE THE REMAINDER OF THE BARS @ APPROX. OR PLATFORM ON THAT PORTION OF THE STAIRWAY. 2X STUDS @ 16" O.C. PARCEL, LOT # 08-079-0021 THE SPACING SHOWN. THE MAXIMUM RISER HEIGHT SHALL BE 7 3/4".. THE GREATEST RISER HEIGHT WITHIN ANY FLIGHT OF STAIRS NOTE: WINDOW WELLS SHALL ALLOW WINS. TO FULLY OPEN & WELLS MORE R-15 INSULATION MIN. SHALL NOT EXCEED THE SMALLEST BY MORE THAN 3/8". THEN 44" DEEP SHALL HAVE APP. FIXED LADDER. WELLS TO HAVE MIN. FARMINGTON, UTAH 9 SQ. FT. CLEAR W/ 36" MIN DIM. LADDER TO BE ACCESSIBLE W/ OPEN WINDOW. & NOT PROTRUDE MORE THAN 6" INTO WELL. UBC 310.4 THE MINIMUM TREAD DEPTH SHALL BE 10". THE GREATEST TREAD DEPTH WITHIN ANY FLIGHT OF 1/2" DIA. ANCHOR BOLTS @ STAIRS SHALL NOT EXCEED THE SMALLEST BY MORE THAN 48" O.C. OR PER ENG. SPECS. 3/8". PRESSURE TREATED GREEN PLATE SCREED ATTIC VENTILATION MATT FROST REINFORCED 4" CONC. SLAB MIN. HANDRAILS SHALL BE PROVIDED ON NOT LESS THAN ONE 6" GRADE COMPACTED SOIL VENTILATION REQUIRED. ENCLOSED ATTICS AND ENCLOSED SIDE OF EACH CONTINUOUS RUN OF TREADS OR FLIGHT WITH FOUR OR MORE RISERS. HANDRAIL HEIGHT, RAFTER SPACES FORMED WHERE CEILINGS ARE APPLIED DIRECTLY TO THE 1- #4 BAR CONTINUOUS 1'-6" MEASURED VERTICALLY FROM THE SLOPED PLANE UNDERSIDE OF ROOF RAFTERS SHALL HAVE CROSS VENTILATION FOR EACH REFER ADJOINGIN THE TREAD NOSING, OR FINISH SURFACE OF ENG. TO SEPARATE SPACE BY VENTILATING OPENINGS PROTECTED AGAINST THE #4 J BARS @ 32" O.C. RAMP SLOPE, SHALL NOT BE LESS THAN 34" AND NOT ENTRANCE OF RAIN OR SNOW. VENTILATING OPENINGS SHALL BE PROVIDED MORE THAN 38" 2- #4 BARS IN FOOTINGS WITH CORROSION-RESISTANT WIRE MESH, WITH 1/8 INCH (3.2 MM) CONTINUOUS MINIMUM TO 1/4 INCH (6.35 MM) MAXIMUM OPENINGS. WINDERS ARE PERMITTED, PROVIDED THAT THE WIDTH OF THE TREAD AT A POINT NOT MORE THAN 12" FROM THE MINIMUM AREA. THE TOTAL NET FREE VENTILATING AREA REFER TO SIDE WHERE THE TREADS ARE NARROWER IS NOT LESS ENGINEERING SHALL NOT BE LESS THAN 1 TO 150 OF THE AREA OF THE SPACE VENTILATED THAN 10" AND THE MINIMUM WIDTH OF ANY TREAD IS FOOTING SCHEDULE EXCEPT THAT THE TOTAL AREA IS PERMITTED TO BE REDUCED TO 1 TO 300, PROVIDED AT LEAST 50 PERCENT AND NOT MORE THAN 80 PERCENT OF THE NOT LESS THAN 6" REQUIRED VENTILATING AREA IS PROVIDED BY VENTILATORS LOCATED IN THE UPPER PORTION OF THE SPACE TO BE VENTILATED AT LEAST 3 FEET SPIRAL STAIRWAYS ARE PERMITTED, PROVIDED THE GENERAL WALL DETAIL SCALE: 1/2" = 1'-0" MINIMUM WIDTH SHALL BE 26" W/ EA. TREAD HAVING A 7 (914 MM) ABOVE EAVE OR CORNICE VENTS WITH THE BALANCE OF THE 1/2" MINIMUM TREAD WIDTH AT 12" FROM THE NARROW REQUIRED VENTILATION PROVIDED BY EAVE OR CORNICE VENTS. AS AN EDGE. ALL TREADS SHALL BE IDENTICAL AND THE RISE ALTERNATIVE, THE NET FREE CROSS-VENTILATION AREA MAY BE REDUCED TO 1 TO 300 WHEN A VAPOR BARRIER HAVING A TRANSMISSION RATE NOT SHALL BE NO MORE THAN 9 1/2". MIN. HEADROOM OF 6'-6" . . ON THE WARM EXCEEDING 1 PERM (57.4 MG/S M Pa) IS INSTALLED SIDE OF THE CEILING. CIRCULAR STAIRWAYS SHALL HAVE A TREAD DEPTH AT A POINT NOT MORE THAN 12" FROM THE SIDE WHERE VENT CLEARANCE. WHERE EAVE OR CORNICE VENTS ARE INSTALLED, INSULATION SHALL NOT BLOCK THE FREE FLOW OF AIR. A MINIMUM OF A 1-INCH (25.4 MM) SPACE SHALL BE PROVIDED BETWEEN THE TREADS ARE ARE NARROWER OF NOT LESS THAN 11". AND THE MIN. DEPTH OF ANY TREAD SHALL NOT BE LESS THAN 6" USEABLE SPACE UNDER STAIRS TO HAVE SECTION AND DETAILS SCALE: 1/4" = 1'-0" THE INSULATION AND THE ROOF SHEATHING AT THE LOCATION OF THE VENT. 5/8" GYPBOARD PAGE # 7 SECTION & DETAILS
FRONT ELEVATION (c) FRONT ELEVATION (b) FRONT ELEVATION SCALE: 1/4" = 1'-0"
Carly Rowe well frost engineering letter 2 messages Shannon Hansell Tue, May 18, 2021 at 8:25 AM To: Larry Famuliner , Chad Boshell , Manjot Masson , Carly Rowe Shannon Hansell Planning/GIS Specialist | Farmington City Office: 801-939-9212 Cell: 385-303-6004 Aqua_Engineering_Well_Memorandum.pdf 444K Manjot Masson Tue, May 18, 2021 at 11:44 AM To: Shannon Hansell Cc: Larry Famuliner , Chad Boshell , Carly Rowe , Jill Jones , Eric Miller Dear All, Due to the unusual request from the homeowner of connecting an ADU to the existing pressurized private lateral, the Sewer District wants to ensure all information is conveyed on the situation. As discussed in DRC, we want to make sure everyone is aware that the homeowner will need to reach out to the E- one/Delco Western representative to ensure that the current pump for the existing home would still work if they added an additional ADU to the private existing lateral and that the currently sized private lateral is sufficient to handle the additional flow. The homeowner will need to ensure the new connection functions and does not impact the services of either home. The District and the City will need to see the results indicating this. In addition, the homeowner has been made aware that if they connect on to their own lateral, they cannot subdivide the property, as per state code. They would have to install a complete separate lateral if they subdivided the property. Property restrictions will be requested from the City by the Sewer District. Since this an uncharted area for the Sewer District, the District will continue to conduct its own research on the current request. The subdivision on Country Lane road was not designed to handle additional homes at the time of it’s design. The Sewer District will want to ensure that there is no impact to the homes on Country Lane Road. Preliminary communication from the E-one/Delco Western representative has indicated not to extend the sewer main further to connect the addition 2 homes that the homeowner is requesting, but to run a parallel line up to the gravity line. If you have any questions, please let me know. I have included the contact information of Delco Western/E-one Representative that the Sewer District has been in contact as well. Kapono Isaacs CELL: (801) 608-1280 OFFICE: (801) 972-0900
FAX: (801) 972-1171 kapono@delcowestern.com Thanks, Manjot K. Masson [Quoted text hidden]
Planning Commission Staff Report June 3, 2021 ______________________________________________________________________________ Item 5: Affordable Housing Zone Text Amendments Public Hearing: Yes Application No.: ZT-1-21 Property Address: NA General Plan Designation: NA Zoning Designation: NA Area: NA Number of Lots: NA Applicant: Farmington City Request: Recommendation to amend the zoning ordinance to require developers of any new dwelling units to set aside a certain percentage of their developments as moderate-income housing, or to pay a fee in lieu, or provide some other benefit. ___________________________________________________________________________ Background Information On February 18, 2021, the Planning Commission tabled consideration of this request to allow time for staff to do the following (text in italics after each point to states what has been done to date). 1. Obtain a recommendation for the same from the City’s affordable housing committee; Members of the committee have reviewed the proposed amendments more than once, and some attend the May 20, 2021 Planning Commission meeting to discuss the amendments in greater detail with the Commission. 2. Explore expanding the scope of the amendments to include every chapter in the zoning ordinance which allows residential development; Complete. 3. Incorporate comments received, if any, from the Planning Commission and the public as part of the proposed amendments as directed by the Commission. Complete. 4. Wait and see what bills are passed by the State this legislative session to assess how such bills may, or may not, effect the proposed zone text amendments. Complete. The proposed draft changes (see below) include results from tasks 1 – 4 above. 1
Suggested Motion Move that the Planning Commission recommend the amendments and new sections to the Zoning Ordinance set forth below: Findings: 1. As required by state law, Farmington City adopted a moderate-income housing plan as an element of the City’s General Plan on October 29, 2019. This plan identified a shortage of housing for existing low to moderate income households in the community. The proposed zone text changes will help the municipality meet its affordable housing needs. 2. The changes are consistent with the Farmington City General Plan. 3. Recent studies show that low to moderate income housing shortages will continue in the future. Changes to the ordinance present a mechanism to help meet the short-fall. Supplemental Information 1. Fee in lieu table/analysis Example Chapter 2 DEFINITIONS 11-2-020: DEFINTIONS OF WORDS AND TERMS: MODERATE INCOME Housing occupied or reserved for occupancy by households with HOUSING a gross household income equal to or less than 80% of the median gross income for households of the same size in the county. Chapter 10 AGRICULTURE ZONES 11-10-035: MODERATE INCOME HOUSING: A. Minimum Requirement: Subdividers must provide or set aside lots (or dwelling units at the option of the City) equal in number to ten percent (10%) of the total number of lots approved for the subdivision for moderate income housing subject to entering into an agreement with the City; unless, at the sole discretion of, and by agreement with the City, the subdivider provides: 1. Open space; or 2. A fee in lieu thereof determined in consideration of factors set forth in Section 11-28-270 of this Title; or 3. Some other public benefit; or 4. A combination of 1, 2, and 3 above. B. Exemption: Subdivisions resulting in two or fewer additional lots are exempt from the minimum moderate-income housing requirements of this Section. 11-10-040: LOT AND SETBACK STANDARDS: 2
A. Minimum Standards: The following shall be the minimum lot areas, widths and main building setbacks in agricultural zones: Zone Lot Area Alternative Lot Width Front Side Side Corner Rear Lot Size1, 2 Interior Corner AA 10 acre 5 acre 150' 160' 40' 15' minimum, total 30' 30' 40' A 2 acre 1 acre 100' 110' 30' 10' minimum, total 24' 25' 30' AE 1 acre 12,000 square 100' 110' 30' 10' minimum, total 24' 25' 30' feet Notes: 1. The total number of lots in the subdivision shall not exceed the total number of lots in a conventional subdivision yield plan. 2. 2. Lot width and setback standards for alternative lot areas may meet such standards set forth in Chapter 12 of this Title. B. Additional Lots Alternatives and Standards: 1. Alternatives i. Open Space 1) Additional lots are those the City approves a transfer of development right as set forth in section 11-28-240 of this title; or obtains improved or unimproved land in fee title, or easement, for public purposes, such as parks, trails, detention basins, etc. The value of which, and the total number of lots related thereto, shall be determined by the City at its sole discretion as part of the subdivision process. Any applicant seeking a TDR must provide a yield plan consistent with the underlying zone and the conventional subdivision standards within that zone, and the yield plan must also conform to subsections 11-12-070A and B of this title. 2) Additional lots under this sub-section are not available for subdivisions consisting of five (5) acres or more, or for subdivisions located in the Conservation Subdivision Overlay Zone. Or ii. Moderate Income Housing The City may approve additional lots than what is conventionally allowed in the underlying zone as an incentive to a subdivider to provide moderate income housing. 2. Standards Lot width and setback requirements for additional lot areas may meet such standards set forth in Chapter 12 of this Title. 3
Chapter 11 SINGLE-FAMILY RESIDENTIAL ZONES 11-11-045: MODERATE INCOME HOUSING: A. Minimum Requirement: Subdividers must provide or set aside dwelling units equal in number to ten percent (10%) of the total number of lots approved for the subdivision for moderate income housing subject to entering into an agreement with the City; unless, at the sole discretion of, and by agreement with the City, the subdivider provides: 1. Open space; or 2. A fee in lieu thereof determined in consideration of factors set forth in Section 11-28-270 of this Title; or 3. Some other public benefit; or 4. A combination of 1, 2, and 3 above. B. Exemption: Subdivisions resulting in two or fewer additional lots are exempt from the minimum moderate-income housing requirements of this Section. 11-11-050: MINIMUM LOT AREA, WIDTH AND SETBACK STANDARDS: A. Minimum Standards: The following shall be the minimum lot areas, widths and main building setbacks for conventional layout subdivision development in single-family residential zones: Zone Conventional Alternative Lot Width Front Side Side Rear Lot Area In Lot Area In Interior Corner Corner Square Feet Square Feet1, 2 R 16,000 8,000 75' 85' 25' 8' minimum, total 20' 30' 18' LR 20,000 10,000 85' 95' 25' 10' minimum, total 20' 30' 22' S 30,000 15,000 95' 100' 25' 10' minimum, total 20' 30' 22' LS 40,000 12,0001 100' 110' 30' 10' minimum, total 25' 30' 24' Notes: 1. The total number of lots in the subdivision shall not exceed the total number of lots in a conventional subdivision yield plan. 2. Lot width and setback standards for alternative lot areas may meet such standards set forth in Chapter 12 of this Title. B. Additional Lots Alternatives and Standards: 3. Alternatives 5
i. Open Space 1) Additional lots are those the city approves a transfer of development right as set forth in section 11-28-240 of this title; or obtains improved or unimproved land in fee title, or easement, for public purposes, such as parks, trails, detention basins, etc. The value of which, and the total number of lots related thereto, shall be determined by the city at its sole discretion as part of the subdivision process. Any applicant seeking a TDR must provide a yield plan consistent with the underlying zone and the conventional subdivision standards within that zone, and the yield plan must also conform to subsections 11-12-070A. and B. of this title. 2) Additional lots under this sub-section are not available for subdivisions consisting of ten (10) acres or more, or for subdivisions located in the conservation subdivision overlay zone. Or ii. Moderate Income Housing The City may approve additional lots than what is conventionally allowed in the underlying zone as an incentive to a subdivider to provide moderate income housing. 4. Standards Lot width and setback requirements for additional lot areas may meet such standards set forth in Chapter 12 of this Title. Chapter 13 MULTIPLE-FAMILY RESIDENTIAL ZONES 11-13-035: MODERATE INCOME HOUSING: A. Minimum Requirement: Developers must provide or set aside dwelling units equal in number to ten percent (10%) of the total number of dwelling units approved for the development for moderate income housing subject to entering into an agreement with the City; unless, at the sole discretion of, and by agreement with the City, the developers provides: 1. Open space; or 2. A fee in lieu thereof determined in consideration of factors set forth in Section 11-28-270 of this Title; or 3. Some other public benefit; or 4. A combination of 1, 2, and 3 above. B. Exemption: Developments resulting in two or fewer additional dwelling units are exempt from the minimum moderate-income housing requirements of this Section. 6
C. Additional Dwelling Units: The City may approve additional dwelling units than what is conventionally allowed in the underlying zone as an incentive to a developer to provide moderate income housing. Chapter 17 ORIGINAL TOWNSITE RESIDENTIAL 11-17-035: MODERATE INCOME HOUSING: A. Minimum Requirement: Subdividers must provide or set aside dwelling units equal in number to ten percent (10%) of the total number of lots approved for the subdivision for moderate income housing subject to entering into an agreement with the City; unless, at the sole discretion of, and by agreement with the City, the subdivider provides: 1. Open space; or 2. A fee in lieu thereof determined in consideration of factors set forth in Section 11-28-270 of this Title; or 3. Some other public benefit; or 4. A combination of 1, 2, and 3 above. B. Exemption: Subdivisions resulting in two or fewer additional lots are exempt from the minimum moderate-income housing requirements of this Section. C. Additional Lots: The City may approve additional lots than what is conventionally allowed in the underlying zone as an incentive to a subdivider to provide moderate income housing. Chapter 18 MIXED USE DISTRICTS 11-18-045: MODERATE INCOME HOUSING: A. Minimum Requirement: Developers must provide or set aside dwelling units equal in number to ten percent (10%) of the total number of dwelling units approved for the development for moderate income housing subject to entering into an agreement with the City; unless, at the sole discretion of, and by agreement with the City, the developers provides: 1. Open space; or 2. A fee in lieu thereof determined in consideration of factors set forth in Section 11-28-270 of this Title; or 3. Some other public benefit; or 4. A combination of 1, 2, and 3 above. B. Exemption: Developments resulting in two or fewer additional dwelling units are exempt from the minimum moderate-income housing requirements of this Section. 7